_JHARSUGUDA 4 GOOMW INDEPENDENCE PORER PLANT PROJECT
Client: SEPCOIJ] ELECTRIC POWER CONSTRUCTION CORPORATION
Turbine Operation and
No. YX-09-O1B Total Pages 225
Maintenance Manual
Operation Instruction
SEPCOLIT
Drafted by: Wang Chongchun —_ July 1, 2009
Reviewed by: Mi Dali duly 1, 2009
Approved by: Guan Ligiang July 1, 2009
CONTENTSE18 JHARSUGUDA 4 60OMW SLE ALi Tet AEE
PART 1 Host Part
Chapter 1 Equipment Production 4
Chapter 2 Equipment Operation a3
Chapter 3 Equipment Running 80
Chapter 4 Equipment maintenance 104
PART 2. Auxilairy Equipment Part wr
Chapter 1 Feed Water Pump 108
Chepter 2 Ciculating Pump 132
Chapter 3. Condensate Pump 138
Chapter 4 Industrial Fater Pump 46
Chapter § Circulating Yater Pump 148
Chapter 6 Open Circulating Cooling Fater Puxp 150
Chapter 7 Closed Circulating Cooling Water Pusp 186
Chapter 8 HP Heater * 161
Chapter 9 LP Heater 169
Chapter 10 Deaerator 174
Chapter 11 Condenser 179
Chapter 12 Lubricating 011 System 186
Chapter 13 Seal Oil System of the Generator 195
Chapter 14 Hydrogen System of the Generator 202
Chapter 15 Generator Stator Coil Cooling Water Systen 2u1
Chapter 16 Turbine Lubricating Oil Purification Equipment 220
Chapter 17 Seal and Vacuum System of the Turbine 224
Chapter 18 DEH System 231
Chapter 19 Bypass System 240
Chapter 20 Generator Stator Coil Cooling Water Control System 252
PART 1 Host Part
Chapter Equipment Production
1.1 Main features:
1.1.1 Turbine frame is compact, three cylinders.
() High pressure and medium pressure (HP pe IP) mar ‘combined cylinder, flow direction opposite.
7 2 :ye JHARSUGUDA 4% GOOMW HLA VMLZ AT Mea HES :
‘wiwo LP parts: A-LP and B-LP part, every low-pressure part is double-triage-style, final stage blade
length is 851mm.
Turbine can quickly start:
@) with complex regulation way (throttle and nozzle adjusting mode).
@ with steam turbine bypass system
With the rotor structure adapting to the quick startup.
4.1.3 Unit has the capabilities of wide range of stable operation:
() partial frequency operation.
(2) Operating under the stable and sliding pressure.
(3)Operation in the peak adjust and continuous basic load
(4)Digital electro-hydraulic control devices. :
1.1.4 Prevent the emergency overspeed of the turbine:
(1) Turbine control valve is equipped with an independent executive body of the rapid response.
(2)Middle reheat valve shall close to the cylinder as near as possible, reduce the amount of the reheat
steam to a minimum,
) With redundancy protection, including mechanical emergency governor and electrical breaker
standby regulator.
@ Rotor has the great moment of inertia.
14.5. Full-capacity oil pump system:
() Hydraulic system has two full-capacity hydraulic pumps.
(2 Turbine lubricating oil system has a main oil pump driven by the turbine shaft.
® Lubricating oil has a main oil pump dtiven by AC motor.
Lubricating ol has a main oil pump driven by DC motor.
1.2. Overview:
1.2. 1 High and medium pressure parts:
‘The HP parts adopt double-cylinder structure designed to reduce the stress and temperature gradient
between the inner and outer cylinder. HP steam enters into the turbine through the independently
installed inal steam valve and governiig Yat
“Theje ‘are two steam inlets on upper and lower