R el ays

Technical Data

Relay 733
Description
Polarized latching relay for 100 A The relays are designed and manufactured in accordance to the Standards of IEC 61810, Part 1-00/VDE 0435, Part 201, which are also in accordance to the Low Voltage Directive (LVD). The advantage of the polarized latching relays is the pulse driv en operation of 30 miliseconds. Therefore there is a low need of setting power and the coil heating can be neglected. Relay can be set by manual operation. The relays are designed and manufactured in accordance to international standards of IEC 61810 part 1/VDE 0435 part 201 as well as they meet overload and short circuit requirements of IEC 62053/62054/62055(UC3).

Technical data
Coil data Rated voltage Rated power Operating power to set Pulse to set Action time Contact data Max. contact arrangement Contact material Max. switching power Max. switching voltage Max. switching current Mechanical life Insulation Creepage and clearance distance coil contact Test voltage coil contact Test voltage contact contact Test voltage open contact Dielectric strength coil contact Ambient temperature Weight Conform to 6 48 VDC 16 W 10.25 W 30 ms < 15 ms 3a AgSnO2 440 VAC 100 A 106 8 mm 4,000 V eff. 1,000 V eff. 12 kV / 1.2 / 50 s -40 +85 C 300 g VDE, UL, CSA, SEV, SEMKO
2011-12-13 Copyright by GRUNER AG Subject to technical changes and design modifications

25,000 VA

General data

1/2

Relay 733

Re l a ys >> Te c h n ic a l Da t a

Standard windings
Standard winding No. Double winding 2R2 9R0 035 140 Nominal coil voltage (VDC) 6 12 24 48 Operating voltage of the coil U1 U2 (VDC) 4.8 7.8 9.6 15.6 19.2 31.2 38.4 62.4 Coil resistance Tolerance

(Ohm) 2 x 2.2 2x9 2 x 35 2 x 140

( %) 10 10 10 10

The relay can also be used with a single winding (lower operating power to set) if the middle pin of coil is not used.

Contact position

Terminal-grid

B 2/3 (+)

1/2 (+)

Identification
733 Identification code Type Version Contact material Contact arrangement Terminal-grid Winding No. 733 D = see dim. drawing R = AgSnO2 3A = 3 normally open B see coil table D R 3A B 9R0

Example for ordering

Further versions on request

The power terminals can be modified according to customer specification.

Technical drawing

ribbon cable or flying leeds tbd 0,50 30,00 20,50 4 3 5 32 6,54 13,7 6,54 10 14 33,54 33,54 33,54 33,54 52 24 132 20 56,8 23,5 8 106,50 8 48,00
2011-12-13 Copyright by GRUNER AG Subject to technical changes and design modifications

1 23

1 23

2 5 6,2

optional: manual override

59,05

67,05

69,00

77,00

733 D

switching p contacts

Terminal p arrangeme

GRUNER AG D-78564 Wehingen Germany Phone +49 7426 948-0 Fax +49 7426 948-200 www.gruner.de info@gruner.de