Anda di halaman 1dari 1

Modular Cleanrooms Technical Specifications

Cleanroom Partitioning System is designed for ease of Ceiling Panels (Walkable / Non-Walkable) Width : 900mm, 1000 mm and 1200 mm
installation and practical functionality, while maintaining Height : Upto 6000 mm with provision for stacked panels for
modular flexibility to interchange by way of easy of de- The ‘walk on’ load bearing roof system, not only provides the
Sizes (Partations higher application
mountability. The system can be integrated with a wide area with an environmentally controlled airflow, with the
and Ceiling Panels) Thickness : 60mm, 80mm and 100mm. Ability to carry and conceal services and
range of new or existing systems to coordinate any control of pressure, temperature, humidity and filtration
return air ducts/raisers from nominally 0.8 mm thick GPSP zero spangle steel
cleanroom facility or manufacturing environment. systems being placed at high level, but also allows for
sheet with riveted construction. Other sizes can be customized based on layout
Simplified construction methods and our progressive/ access of maintenance personnel whilst not encroaching
non-progressive system will help minimize overall within cleanroom envelope.
construction time. Ceiling system is designed not only to achieve its load Recessed adjustable floor track to compensate floor undulations and allow
bearing function but to add clean single joints to create a Floor Track flush coved finish.
Solid Panels for Cleanroom Partitions sleek clean flush surface.
Modular walls have been installed in cleanrooms PUF (Polyurethane Foam)
Innovative plank system allows the overall load of the ceiling PIR (Poly ISO Rinate)
throughout the world in a range of applications from high Infill
to be spread by interconnection of joints on the panel Honeycomb Kraft paper
technology electronic manufacturing to legislation-
edges, whilst being supported at the intermediate points by Mineral wool/Glass wool/Rock wool
controlled healthcare packaging.
lattice beams over head, with a load of 150kgs which
Weight 9 kg/m² to 25 kg/m² dependant upon specification and thickness.
The system is readily adaptable to meet the includes 2 persons with toolkits.
requirements of most cleanroom classifications as Polyester powder coated/Precoated galvanized steel/Stainless Steel
Design engineers will calculate all loadings required to Surface Finish Polyester powder coated/Precoated galvanized steel/Stainless Steel
determined by cGMP grades used in pharmaceutical Colour : Suitable RAL Colours
incorporate flush light fittings, HEPA filters, diffusers etc.
applications. Make-up panels are produced within the Each panel is connected to it’s adjacent unit or door unit with a friction type
Load bearing ceiling system is fully de-mountable and Panel Connection
sizing layout of the drawing. interlocking key. This allows speedy erection and dismantling.
compatible with our wall systems and will meet all
A complete range of partition walls and ceiling systems requirements where hygiene and cleanliness are a Glazing Double flush glazing with 6mm toughened glass on both sides with in a frame.
are available to meet the technical specifications of requirement. Door leaf from 0.8 mm /1.2 mm thick slip coated pre-galvanised steel sheet to ASTM A527/ ASTM
controlled environment rooms. Ceilings as well as A525, JIS G 3302 or BS 2989 (1994). Zinc coating 80-120 g/m2. Lock formed panels with internal
partitions are inert, non particle-shedding, forming part
stiffeners, 3.0mm thick hinge reinforcing, hardware mounting plates and lock protection.
of a cleanroom aseptic envelope to enable compliance
with FDA validation procedures and cGMP standards. Door Stiffeners are used to provide extra strength and to prevent de-formation in doors
Door frame from 1.2 mm / 1.6 mm thick pre-galvanised steel sheet with mitred and welded
corners, frame stretchers, hinge reinforcing plates, fixing plates and hardware mounting plates.
Coving Optional radiused floor/ceiling coving accessories.
Air Leakage Silicon for sealed applications
Concealed system provided by using inbuilt conduit with Electrical/Telephone/LAN
/module boxes installed with in the panel.
Integration All cutouts are factory made and properly sealed.
Optional items like wall guard, crash panel for the emergency exit, removable
panels for the equipment movement can be given.

Note : The sizes of panels and ceilings depend on customer requirement and site conditions