Mapinfo Automator
By Mazhar Kazi
2. Mapinfo Automator
Mapinfo Automator is a mapbasic tool that does variety of task from Drive test analysis to Cluster KPI computing and much more. Used for Cluster KPI Computing
Displays the Drive Selection Menu About the Tool Enable the Cell Selection Mode The basic features of the tool are discussed below:-
2.1.
The Cluster KPI Computing function can be used to process raw stats on custom selection of cells and displays the graphical trend of major KPIs in Mapinfo. This is helpful in identifying cluster level improvement or degradation.
RF Optimization Tools
Page 2
by Mazhar Kazi
2.2.
In the Drive Selection Menu select the Map File of the drive and click Reduce Size Button.
RF Optimization Tools
Page 3
by Mazhar Kazi
Select the below mentioned parameters in the drive selection menu and click button Done. Select the Tems exported Map file.
In the tool menu select the Cell Selection Mode Button and select any cell in the cell file to display its strongest server plot.
RF Optimization Tools
Page 4
by Mazhar Kazi
2.2.1.1.2.
In Figure: - Three cells have the same BCCH (63) in this area. The labels of 27, 65 & 63 are the BSIC of these cells.
It filters the BCCH of the cell that is selected irrespective of the BSIC.
RF Optimization Tools
Page 5
by Mazhar Kazi
2.2.2.
RF Optimization Tools
Page 6
by Mazhar Kazi
2.2.2.3. Plots
After Processing the dedicated drive the tool generates four plots which are described below:-
2.2.2.3.1.
Quality Plot
The averaged quality of every cell in the drive is calculated and is plotted on the CELL_FILE(CF) with the quality thematic. This instantly helps in identifying bad quality cells in the drive.
2.2.2.3.2.
BCCH Plot
The Cell_File(CF) and the drive thematic is based on the BCCH. It is helpful in determining the coverage area of a cell, overshooting and low dominance etc
RF Optimization Tools
Page 7
by Mazhar Kazi
2.2.2.3.3.
TA Plot
The averaged TA of every cell in the drive is calculated and is plotted on the CELL_FILE(CF) with the TA thematic. This instantly helps in identifying Overshooting cells in the drive.
Low TA Cell
High TA Cell
2.2.2.3.4.
Call is not handed over to this cell during the drive. Might be a missing neighbor, Unavailability etc.
Note: All the above plots can be viewed with simple keyboard shortcut keys. Z Quality Plot, X BCCH Plot, C TA Plot, V Speech Codec Plot.
RF Optimization Tools
Page 8
by Mazhar Kazi
2.2.2.4
InterCell Handovers
Each Line represents a single InterCell Handover during the drive. The source point is the source cell i.e. from which the handover is initiated and the destination point is the location where the handover took place.
RF Optimization Tools
Page 9
by Mazhar Kazi