Anda di halaman 1dari 179

LA TERMOTECNICA

Termocoppie - Termoresistenze - Controlli di processo Thermocouples - RTD s - Proces controls

Laboratory instrumentation

Calibration center

P r o f i l o Factory profile aziendale Main index

LA TERMOTECNICA TERMOTECNICA LA

Temperature probes Catalogo sonde termiche Thermocouples - RTD s Electric heaters

THERMOCOUPLES

LA TERMOTECNICA

LA TERMOTECNICA, an Italian company set up in 1976, is one of the leading companies in Italy in the production and design of temperature sensors based on proprietary thermocouple and RTD technology. Over the years, the quality and reliability of LA TERMOTECNICA products have secured the company a forefront position on the Italian and international marketplace. Since the company was set up 25 years ago, top flight product quality and efficient services have always been high on it s list of priorities. These services include technical support and assistance able to solve any application problems, fast, certain delivery, R&D activities, issue of quality certification documents, in other words a complete suite of services that only a company with it s sights firmly set on leadership can sustain. Obviously, all to the advantage of the customer who can always rely on a prompt, efficient partner at all times.

RTD s

Production:
Our Moncalieri (TURIN) facility turns out RTD and thermocouple type temperature sensors. The thermocouples are available in the classical version with calibrated wires and insulators or with MgO (magnesium oxide) insulation both in base and noble metal. Assembled to DIN, ASTM, CTI-UNI specs. The RTDs in the 50-100-1000 Ohm series at C assembled inside protective sheaths according to requirements of use and insulated with ceramic insulators or with MgO (magnesium oxide) insulation. Assembled to DIN, UNI specs. In both cases, product lines are available according to use (standard series, TSM series, MgO series for aerothermal recordings, full cable series, etc.). We are renowned for our versatility and flexibility and are able to supply custom designed products adapted to specific requirements and with the precision requested by the customer. All our products are subject to a process control system that makes it possible to apply a FULL TESTED procedure that guarantees functional testing of each single product before this is declared suitable.

Distribution, sales and services:


Our production activities are flanked by a set of services including the sale of instruments, accessories such as extension cables for thermocouples and RTDs, compensating cables, connection heads, linearized temperature and pressure transmitters, infrared measurement instruments. Our calibration laboratory means we can issue calibration certificates in the range 30 to + 1064C with S.I.T. (Italian Calibration Service) traceability.

Via Peschiera, 20 Tel. 011/642007 (5 r.a.)-Fax 011/642098 E-mail: info@latermotecnica.it

Contact our sales office for any further information Our WEB SITE http://www.latermotecnica.it LA TERMOTECNICA s.n.c. 10024 Moncalieri (Torino) Italy

THERMOCOUPLES

Standardized temperature probes (on catalogue products):


Different type of temperature probes for any industrial application, that is possible to order following the guidelines of our catalogue. -Standard thermocouple serie -TSM sereies -Mineral insulated serie, thermocouples -Mineral insulated serie, RTD s -Mineral insulated serie, thermocouples with connecting head -Mineral insulated serie, RTDs with connecting head -Full cable serie, thermocouples -Full cable serie, RTD s -Duct e pipe aerothermic probes -Bayonet fitting thermocouples -Bayonet fitting RTD s -Compression fittings -Thermowells -Micro thermocouples -Extension for thermocouples and RTD s And others more.

LA TERMOTECNICA

RTD s

Custom designed products


Thermocouples and RTDs for specific applications in the following sectors: Automotive Avionics Marine Chemical Food Petrochemical Cement and klinker industry Most of these products are specifically designed to the customers specifications and are produced according to the test standard based on the FULL TESTED procedure.

Contact our sales office for any further information Our WEB SITE http://www.latermotecnica.it LA TERMOTECNICA s.n.c. 10024 Moncalieri (Torino) Italy

Via Peschiera, 20 Tel. 011/642007 (5 r.a.)-Fax 011/642098 E-mail: info@latermotecnica.it

THERMOCOUPLES

DISTRIBUTION and SERVICES


1 TEMPERATURE SECTOR

RTD s

1.1

EXTENSION CABLES FOR THERMOCOUPLES AND RTD s PROBES, CONNECTORS MULTICHANNEL SWITCHS FOR THERMOCOUPLES AND RTD s

LA TERMOTECNICA

1.2

THERMOREGULATORS AND METERS, CONTROL AND REGULATION SYSTEMS. CONTROL AND PLANT MANAGEMENT SOFTWARE

1.3

PORTABLE OR BENCH THERMOMETERS FOR THERMOCOUPLES AND RTDS, MEASUREMENT BRIDGES

1.4

PORTABLE AND FIXED CALIBRATION SYSTEMS, THERMOSTAT-CONTROLLE HIGH STABILITY INSTRUMENTS AND SOURCES OF HEAT. TURN-KEY CALIBRATION SYSTEMS.

1.5

TRADUCERS, SIGNAL CONDITIONERS WITH CURRENT LOOP OR VOLTAGE OUTPUTS FOR PANEL OR CONNECTION HEAD ASSEMBLY.

Via Peschiera, 20 Tel. 011/642007 (5 r.a.)-Fax 011/642098 E-mail: info@latermotecnica.it

Contact our sales office for any further information Our WEB SITE http://www.latermotecnica.it LA TERMOTECNICA s.n.c. 10024 Moncalieri (Torino) Italy

THERMOCOUPLES

1.6

LA TERMOTECNICA

RTD s

MULTIFUNCTION PORTABLE AND BENCH TYPE CALIBRATORS FOR THERMOCOUPLES AND RTDS

1.7

DOT OR TRACE LOGGERS, DATALOGGERS, PLOTTERS, DISK ENCODERS. TEMPERATURE PROFILER, WIRELESS SYSTEMS

1.8

PORTABLE AND FIXED INFRARED TEMPERATURE MEASUREMENT SYSTEMS FOR TEMPERATURES UP TO 3000C, INFRARED PHOTOGRAPHIC SYSTEMS, METERS AND SENSORS.

1.9

ANALOG DIGITAL DATA ACQUISITION SYSTEMS THAT CAN BE CONNECTED TO PC FOR TEMPERATURES, CURRENTS, VOLTAGES, FREQUENCIES. MANAGEMENT AND DATA PROCESSING SOFTWARE. BOARDS FOR ISA, PC, XT, AT, PCMCIA BUSES FOR ANALOG-DIG/DIG-ANALOG/DIG-DIG DATA ACQUISITION, MANAGEMENT AND DATA ACQUISITION SOFTWARE. TURN-KEY SYSTEMS

Contact our sales office for any further information Our WEB SITE http://www.latermotecnica.it LA TERMOTECNICA s.n.c. 10024 Moncalieri (Torino) Italy

Via Peschiera, 20 Tel. 011/642007 (5 r.a.)-Fax 011/642098 E-mail: info@latermotecnica.it

THERMOCOUPLES

2 ELECTRONIC INSTRUMENTATION

RTD s

2.1

LA TERMOTECNICA

PORTABLE AND BENCH TYPE MULTIMETERS. SCANNERS, MANAGEMENT AND PROCESSING SOFTWARE. IMPULSE METERS, FREQUENCY METERS, REV COUNTERS, POWER SUPPLIES. OSCILLOSCOPES.

3 FORCE AND PRESSURE


3.1
ABSOLUTE, RELATIVE, VACUUM PRESSURE TRANSDUCERS WITH CURRENT LOOP OR VOLTAGE OUTPUT. METERS, PORTABLE AND PANEL TYPE READERS AND CALIBRATORS. STRAINGAUGES, LOAD CELLS.

4 RESISTOR HEATERS
4.1
ELECTRICAL RESISTORS FOR ALL TYPES OF ELECTRICAL FURNACES INDUSTRIAL FOR HEAT TREATMENT, ANNEALING, CASE-HARDENING, NITRIDING. IN KANTALL, NITROTAL, SILICON CARBIDE ALLOYS. ARMORED RESISTORS, CARTRIDGE TYPE FOR PLASTIC AND MOLDING SYSTEMS.

Via Peschiera, 20 Tel. 011/642007 (5 r.a.)-Fax 011/642098 E-mail: info@latermotecnica.it

Contact our sales office for any further information Our WEB SITE http://www.latermotecnica.it LA TERMOTECNICA s.n.c. 10024 Moncalieri (Torino) Italy

Main index
Standard serie thermocouples With stainless steel protection tube With ceramic protection tube Stainless steel protection tube replacements Ceramic protection tube replacements Inlet replacements brobe for stamdard serie thermocouples TSM serie With stainless steel protection tube With stainless steel protection tube and spring loaded insert With stainless steel protection tube and transmitter Inlet replacements probe for TSM serie Inlet replacements probe with transmitter for TSM serie Mineral insulated thermocouples series (MgO) 1 2 3 5 6 7 8 9 10 11 12 13 14

With standard type compensated connector 15 With standard type compensated connector and fixed fitting 16 With standard type compensated connector and compression fitting 17 Double element with standard type compensated connector 18 Double element with standard type compensated connector and fixed fitt. 19 Double element with standard type compensated connector and comp. fitt. 20 With miniature type compensated connector 21 With miniature type compensated connector and fixed fitting 22 With miniature type compensated connector and compression fitting 23 Double element with miniature type compensated connector 24 Double element with miniature type compensated connector and fixed fitt. 25 Double element with miniature type compensated connector and comp.fitt. 26 Mineral insulated thermocouples series (MgO) with integrated extension cable Without fittings With fixed fitting With compression fitting With compensated connector With compensated connector and fixed fitting With compensated connector and compression fitting Mineral insulated RTD s PT100 (MgO) with integrated extension cable Without fittings With fixed fitting With compression fitting Mineral insulated RTD s PT100 (MgO) with connector type LEMO B Without fittings With fixed fitting With compression fitting 36 37 38 33 34 35 27 28 29 30 31 32

LA TERMOTECNICA s.n.c. 10024 Moncalieri (Torino) Italy


Via Peschiera, 20 Tel. 011/642007 (5 r.a.)-Fax 011/642098 E mail:info@latermotecnica.it

Mineral insulated RTD s PT100 (MgO) with connector type amphenol Extensions cables with connectortype LEMO B Extensions cables with connectortype amphenol Mineral insulated thermocouples series (MgO) with connecting head Without fittings With fixed fitting With compression fitting Mineral insulated RTD s PT100 (MgO) with connecting head Without fittings With fixed fitting With compression fitting Full cable series thermocouples With braided glass insulated cable With teflon insulated cable With silicon rubber insulated cable With PVC insulated cable Full cable series RTD s PT100 With braided glass insulated cable With teflon insulated cable With silicon rubber insulated cable With PVC insulated cable Full cable style RTD s with transition, for up to 500 C With PVC insulated cable With silicon rubber insulated cable With braided glass insulated cable Full cable style probes for aerothermal relief With PVC insulated cable With silicon rubber insulated cable With braided glass insulated cable Wall mounting probes Duct & pipe mounting probes Full cable style thermocouples with male bayonet fitting Standard With female bayonet fitting

39 40 41

42 43 44

45 46 47 48 49 50 51 52

53 54 55 56

57 58 59

60 61 62 63 64

65 66

LA TERMOTECNICA s.n.c. 10024 Moncalieri (Torino) Italy


Via Peschiera, 20 Tel. 011/642007 (5 r.a.)-Fax 011/642098 E mail:info@latermotecnica.it

Full cable style RTD s PT100 with male bayonet fitting Standard With female bayonet fitting Full cable style thermocouples with brass sensing head Thermowells for MgO series probe With stainless steel protection tube With ceramic protection tube Micro thermocouples With silicon rubber insulated cable With PVC insulated cable With braided glass insulated cable With teflon insulated cable Full cable style thermocouples for pipe or plate Accessories Thermowells in brass or stainless steel Compression fittings Extension for thermocouples with integrated connectors Compensated connectors for thermocouples Thermocouples and RTD s cables Teflon insulated cables Glass braid insulated cables Silicone rubber insilated cables PVC insulated cables Compensating cables Temperature transmitters Calibration and certification Technical notes Thermocouples RTD s General Tables Temperature vs. F.E.M. Thermocouple K type IEC 584-1 . ITS90 Temperature vs. F.E.M. Thermocouple J type IEC 584-1 . ITS90 Temperature vs. F.E.M. Thermocouple T type IEC 584-1 . ITS90 Temperature vs. F.E.M. Thermocouple N type IEC 584-1 . ITS90 Temperature vs. F.E.M. Thermocouple S type IEC 584-1 . ITS90 Temperature vs. F.E.M. Thermocouple E type IEC 584-1 . ITS90 Temperature vs. Resistance RTD type PT100 IEC 751-1 . ITS90 International Thermocouple cables color coding 135 141 145 72 73 74 75 76 77 78 79 80 81 83 84 86 87 88 89 90 129 70 71 67 68 69

LA TERMOTECNICA s.n.c. 10024 Moncalieri (Torino) Italy


Via Peschiera, 20 Tel. 011/642007 (5 r.a.)-Fax 011/642098 E mail:info@latermotecnica.it

ORDER CODE EXAMPLE Mineral insulated thermocouple (MgO), with standard type compensated connector

Whit plastic connector (max 220 C) Whit ceramic connector (max 550 C)

G A G B

Model

A B C

0 0

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Type and class of tolerances J E K N S R J E K N S R

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

A J E K N S R 2 3 4 5 6 7

Hot junction type Ungraunded Grounded Exposed

C I M E

Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600 2 A G Q 3 3.17 B C J I R S 4 4.5 D E L M T U

D 6 F O Z

Sheath diameter(mm)

Model G A

K I

R 0 1 5 0 0

0 0

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Code for: Mineral insulated thermocouple (MgO) type K diam. 3 mm, sheath quality inconell 600, lenght L=1500mm and ungrounded hot junction Model GA KIR0150000

Standard serie
Metallic protection tube A0-A1-A2-A3-A4
THERMOCOUPLE
With their simple but rugged construction, this series of thermocouples is suitable for all applications in which the protective barrier of the sensing element is of fundamental importance. Protection is assured by the quality of the external protection tubes (AISI series 400, 300 and INCONEL 600) that guarantee effective protection against gas corrosion even at high temperatures. According to the harshness of the environment, they are available with single or double protection tube (steel on the outside and ceramic inside), with the typical elements consisting of calibrated wires and ceramic insulators or with magnesium oxide insulators.

LA TERMOTECNICA

RTD' S PROBE

Tipical Applications:

Chemical and petrochemical industry Iron and steel industry Bulding material industry
LA TERMOTECNICA, produce in according to internal higth quality standards, and in accordance with international standards :

UNI 7938 IEC 584 ANSI / DIN


Utilization of special productive plants as, microscopes, custom welding machines, micro-manipulators, and above all ,our high level staff, assure quality standard and precision. If requested we supply documentation and product certification.

STANDARD SERIE THERMOCOUPLES WITH STAINLESS STEEL PROTECTION TUBE

LA TERMOTECNICA
Thermoucoples and Rtd's

Model Model

A 0 A B C D E

A 1

A 2 F

A 3

A 4
Technical data

Type and class of tolerances Hot junction type Sheath quality Connecting head Fittings or flanges Length L (mm) Internal probe construnction
Type and class of tolerances E K N S R E K N S R A E K N S R 3 4 5 6 7

-Temperature working range: 0 .. 1200 C max (warning !! in reference of thermocouple type and protecting tube material, check technical notes) -Accuracy: in reference of ANSI MC96.1/IEC 584 -Protection: IP55 -Electrical connection 1/2" gas

Connecting head

Wiring

Thermocouple,tolerances according to Ansi GrI

DIN B Head

DIN A T1 Head

Thermocouple,tolerances according to Ansi GrII

1xTC
BUS Head P Explosionproof Head D

2xTC
F A B

Internal probe construction Ceramic insulators and wire insert Mineral insulated insert

Hot juntion type One junction whit ceramic insulators Two junction whit ceramic insulators One junction mineral insulated Two junction mineral insulated

B
Ungrounded

B Exposed 3 5 A C

1 4 9 B

Flanges (UNI 2278 PN16) for model A4 A B C D 90 60 12 14 95 65 12 14 105 70 14 14

E Q R S

Flanges (UNI 2278 PN16) for model A0 E A 70 100 C 6 9 T U

Sheath quality C Sheath diameter (mm) S.S. Quality 12 14 15 16 3/8 20 1/2 3/4 T H Aisi 446 1 Aisi 446* I L C M N O P Aisi 310 2 E 3 4 5 6 Aisi 310* Q R S U Inconel 600 7 8 9 Inconel 600*

Stainless steel fittings for model A1-A2-A3 E

F (gas)
3/8 1/2" 3/4" 1" 1" 1/4 1" 1/2 2"

Sheath diameter (mm)

*Whit added inner ceramics protection

12 2 3 4 5 6 7 8

14 15 16 3/8 20 1/23/4 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8

4 5 6 7 8

4 5 6 7 8

5 6 6 7 7 8 8

Custom executions on request

Standard serie
Ceramic protection tube C1-C2-C3-C4
THERMOCOUPLE
This series of thermocouples offers a wide variety of choice, allowing the designer to cater to a broad range of application requirements with the possibility of selecting ceramic protection tubes (in the various commercial diameters), the total number of protection tubes (from one to three) and also different solutions as regards the type of connection head, fittings, the number and type of internal probes. These thermocouples are normally used in processes in which the operating temperature does not permit use of metal protection tubes. They are constructed mainly with noble metal internal probes (Platinum, type S, R, B). However, there are many applications in which base metal elements can be used but use of metal protection tubes is not recommended in view of the temperatures involved. Tipical applications:

LA TERMOTECNICA

RTD' S PROBE

Glass industry Stacks, incenerators Ceramic industry


LA TERMOTECNICA, produce in according to internal higth quality standards, and in accordance with international standards :

UNI 7938 IEC 584 ANSI / DIN


Utilization of special productive plants as, microscopes, custom welding machines, micro-manipulators, and , above all our high level staff, assure quality standard and precision. If requested we supply documentation and product certification.

STANDARD SERIE THERMOCOUPLES WITH CERAMIC PROTECTION TUBE

LA TERMOTECNICA
Thermoucoples and Rtd's

Model Model

C 1

C 2 F

C 3

C 6
Technical data
-Temperature working range: 0 .. 1600 C max (warning !! in reference of thermocouple type and protecting tube material, check technical notes) -Accuracy: in reference of ANSI MC96.1/IEC 584 -Protection: IP55 -Electrical connection 1/2" gas

A B C D E

Type and class of tolerances Hot junction type Sheath protection Connecting head Fittings or flanges Length L (mm) Internal probe construnction
Type and class of tolerances E K N S R E K N S R A E K N S R 3 4 5 6 7
B 1 2
C

Connecting head

Wiring

Thermocouple,tolerances according to Ansi GrI

DIN B Head

DIN A T1 Head

Thermocouple,tolerances according to Ansi GrII

1xTC
BUS Head P Explosionproof Head D
E Q R S T

2xTC

Element type Single element Double element


Sheath protection
Sheath diameter (mm) Rod diameter (mm) 6 8

10 15 16 17 20 26

Flange (UNI 2278 PN16) per serie C6 A B C D 90 60 12 14 95 65 12 14 105 70 14 14 115 75 14 14


Stainless steel fittings for model C2-C3

10 12 14 20 1/2" 1/2" 3/4" 32

A B C D E F 1 Ceramic(610) G H I L 2 Ceramic(610) 1Ceramic(610) M N O P Q R 1Ceramic(710) V 1Ceramic(710) R S T U Z 1 2 Ceramic(710) 1 Ceramic(530) 2 2 Ceramic(610) 1 Ceramic(530) 3 1 Ceramic(610) 1 Ceramic(710) 1Ceramic(530) 4 2 Ceramic(710)

F (gas)
3/8 1/2" 3/4" 1" 1" 1/4 1" 1/2 2"

Sheath diameter (mm)

10 12 14 20 1/2 3/4 32 E F F G G G G H H H H H I I I I I I L L L L L L L M M M M M M M
F A B

Internal probe construction Ceramic insulators and wire insert Mineral insulated insert

Custom execution on request

REPLACEMENTS FOR THERMOCOUPLES STANDARD SERIE, WITH STAINLESS STEEL PROTECTION TUBE (MODEL A0-A1-A2-A3-A4)

LA
Model Model

TERMOTECNICA
and Rtd's
A L A R A E A G A F
Technical data
-Temperature working range: 0 .. 1200 C max (warning !! in reference of thermocouple type and protecting tube material, check technical notes) -Accuracy: N/A -Protection: IP55

Thermoucoples

A B C 1 0 0

Sheath quality Thread F Fittings or flanges Standard length Length L (mm)


Sheath quality A Sheath diameter (mm) S.S. Quality 12 14 15 16 3/8 20 1/2 3/4 T H Aisi 446 1 Aisi 446* I L C M N O P Aisi 310 2 E 3 4 5 6 Aisi 310* Q R S U Inconel 600 7 8 9 Inconel 600*

Thread F 1/2" 3/4"


Flanges (U N I 2278 PN 16) for model AF A 90 95 105 B 60 65 70 C 12 12 14 D 14 14 14

B 2 4
C

Q R S

Flanges (UNI 2278 PN16) for model AL C A C T 70 6 U 100 9

Stainless steel fittings for model AR-AE-AG C

F (gas)
1/2" 3/4" 1" 1" 1/4 1" 1/2 2"

Sheath diameter(mm)

12 3 4 5 6 7 8

14 3 4 5 6 7 8

15 3 4 5 6 7 8

16 3/8 20 1/23/4 3 4 4 4 5 5 5 5 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8

Custom execution on request

REPLACEMENTS FOR THERMOCOUPLES STANDARD SERIE, WITH CERAMIC PROTECTION TUBE (MODEL C1-C2-C3-C6)

LA

TERMOTECNICA
and Rtd's
Model C L C R C G C E
Technical data
-Temperature working range: 0 .. 1600 C max (warning !! in reference of thermocouple type and protecting tube material, check technical notes) -Accuracy: N/A -Protection: IP54

Thermoucoples

Model

A B C 1 0 0

Sheath protection Thread F Fittings or flanges Standard length Length L (mm)


Sheath protection
Sheath diameter (mm) Rod diameter (mm) 6 8

Flanges (UNI 2278 PN16) for model CE

C Q R S

10 15 16 17 20 26

10 12 14 20 1/2" 1/2" 3/4" 32

A B C D E F 1 Ceramic(610) G H I L 2 Ceramic(610) 1Ceramic(610) M N O P Q R 1Ceramic(710) V 1Ceramic(710) R S T U Z 1 2 Ceramic(710) 1 Ceramic(530) 2 2 Ceramic(610) 1 Ceramic(530) 3 1 Ceramic(610) 1 Ceramic(710) 1Ceramic(530) 4 2 Ceramic(710)

A 90 95 105

B 60 65 70

C 12 12 14

D 14 14 14

T hread F1 1/2" 3/4"

B 2 4

Stainless steel fittings for modell CR-CG

F (gas)
3/8 1/2" 3/4" 1" 1" 1/4 1" 1/2 2"

Sheath diameter (mm)

10 12 14 20 1/2 3/4 32 E F F G G G G H H H H H I I I I I I L L L L L L L M M M M M M M

Custom execution on request

INLET REPLACEMENTS PROBE FOR THERMOCOUPLES STANDARD SERIE

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model Model A B

A I C C D 0

A O
Technical data
-Temperature working range: 0 .. 1600 C max (warning !! in reference of thermocouple type and protecting tube material, check technical notes) -Accuracy: in reference of ANSI MC96.1/IEC 584 -Protection: N/A

Type and class of tolerances Internal probe construction Length L (mm) Ceramic junction type Hot junction type

Type and class of tolerances J E K N S R J E K N S R

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

A J E K N S R 2 3 4 5 6 7

Internal probe construction Ceramic insulators and wire insert Diameter wire Element 0.35 single 0.35 double 0.5 single 0.5 double 1.63 single 1.63 double 2.3 single 2.3 double 3.26 single 3.26 double Mineral insulated insert Diameter Mgo Element 3 single 3 double 4 single 4 double 4.5 single 4.5 double 6 single 6 double 8 single 8 double

Wiring

1 2 3 4 5 6 7 8 9 0

1xTC

2xTC

Ceramic junction block Whitout ceramics junction block For DIN B / BUS head For DIN A T1 head For explosionproof head

C C S C C C Z B L D

Hot junction type Ungrounded Grounded Exposed


For model AI only exposed

D I M E

G H L M A B C D E F

Custom execution on request

TSM serie
THERMOCOUPLE RTD' S PROBE
This series of simple but sturdy thermocouples and RTDs is suitable for all applications in which the operating temperature permits use of protection tubes made of less noble materials than in the standard series (AISI 446AISI 310-INCONEL 600).The protection materials of this series are made mainly of AISI 304 for general use and AISI 316 for applications in the food industry. This series can be constructed with thermocouple internal probe(K J E T configurations) or with RTD elements (Pt100) with 2-3-4 wire connections.

LA TERMOTECNICA

Tipical applications: Process Food indystry Chemical industry


LA TERMOTECNICA, produce in according to internal higth quality standards, and in accordance with international standards :

UNI 7938 IEC 584 ANSI / DIN


Utilization of special productive plants as, microscopes, custom welding machines, micro-manipulators, and above all our high level staff, assure quality standard and precision. If requested we supply documentation and product certification.

TSM TEMPERATURE PROBE, WITH STAINLESS STEEL PROTECTION TUBE

Technical data
-Temperature working range: -50 .. 450 C (warning !! T type thermocouple 400 C max.) -Accuracy: ANSI MC96.1/IEC 584 (thermocouple probes) DIN 43760/IEC 752/UNI 7937 (RTD probes) -Protection: IP55 -Electrical connection 1/2" gas

LA
Model Model M 1

TERMOTECNICA
and R td's Wiring
M 2 M 3 M 4 0
1xTC 2xTC

Thermoucoples

A B C D E

Type and class of tolerances Hot junction type Connecting head Sheath quality Fittings Length L (mm)
Type and class of tolerances Thermocouples,tolerances according to Ansi GrI T J E K T J E K A T J E K 1 2 3 4 A B C D E
B 1 4 2 1 2 3 4 5
Sheath quality s.s Quality Aisi 304 Aisi 316

1xPT100 3 wire

1xPT100 4 wire

2xPT100 3+3 wire

Sheath diameter (mm) 4 5 6 8 10 12 14 1 2 3 B E F G A B C 4 5 6 7

Thermocouples,tolerances according to Ansi GrII


RTD pt100 OHM a 0 C 1 DIN RTD pt100 OHM a 0 C 1/2 DIN RTD pt100 OHM a 0 C 1/3 DIN RTD pt100 OHM a 0 C 1/5 DIN RTD pt100 OHM a 0 C 1/10 DIN

Fittings E Stainless steel Sheath diameter (mm) fittings for model 6 8 10 12 14 M2-M4 1/8 A 1/4 B B Thread F 3/8 C C C C 1/2 D D D D D Fittings E Stainless steel Sheath diameter (mm) compression fittings 6 8 10 12 14 for model M3 1/8 A 1/4 B B Thread F 3/8 C C C C 1/2 D D D D D

Hot juntion type Thermocouple Ungrounded (single element) Ungraunded (double elements) Graunded RTD One pt 100 a 2 wire One pt 100 a 3 wire One pt100 a 4 wire Two pt100 a 2 wire Two pt100 a 3 wire

Connecting head

DIN B Head

Mignon Head

Fittings E Brass compression Sheath diameter (mm) fittings for model 6 8 10 12 14 M3 1/8 A 1/4 B B Thread F 3/8 C C C C 1/2 D D D D D

Miniature Head

BUS Head

Custom execution on request

TSM TEMPERATURE PROBE WITH SPRING LOADED INSERT

Technical data
-Temperature working range: -50 .. 450 C (warning !! T type thermocouple 400 C max.) -Accuracy: ANSI MC96.1/IEC 584 (thermocouple probes) DIN 43760/IEC 752/UNI 7937 (RTD probes) -Protection: IP55 -Electrical connection 1/2" gas

LA
M A

TERMOTECNICA
and Rtd's
Wiring

Thermoucoples

Model Model

M B

M C

M D E 0
1xTC 2xTC

A B C D

Type and class of tolerances Hot junction type Sheath quality Fittings Lenght L (mm) Connecting head
Type and class of tolerances Thermocouples,tolerances according to Ansi GrI T J E K T J E K A T J E K 1 2 3 4 A B C D E

1xPT100 3 wire

1xPT100 4 wire

2xPT100 3+3 wire

Thermocouples,tolerances according to Ansi GrII


RTD pt100 OHM a 0 C 1 DIN RTD pt100 OHM a 0 C 1/2 DIN RTD pt100 OHM a 0 C 1/3 DIN RTD pt100 OHM a 0 C 1/5 DIN RTD pt100 OHM a 0 C 1/10 DIN

Fittings D Stainless steel Sheath diameter (mm) fittings for model 6 8 10 12 14 MD-MB 1/8 A 1/4 B B Thread F 3/8 C C C C 1/2 D D D D D Fittings D Stainless steel Sheath diameter (mm) compression fittings 6 8 10 12 14 for model MC 1/8 A 1/4 B B Thread F 3/8 C C C C 1/2 D D D D D Fittings D Brass compression Sheath diameter (mm) fittings for model 6 8 10 12 14 MC 1/8 A 1/4 B B Thread F 3/8 C C C C 1/2 D D D D D

Hot juntion type Thermocouple Ungrounded (single element) Ungraunded (double elements) Graunded RTD One pt 100 a 2 wire One pt 100 a 3 wire One pt100 a 4 wire Two pt100 a 2 wire Two pt100 a 3 wire

B 1 4 2 1 2 3 4 5

Connecting head

Sheath quality s.s Quality Aisi 304 Aisi 316

Sheath diameter (mm) 4 5 6 8 10 12 14 1 2 3 B E F G A B C 4 5 6 7

DIN B Head

B Explosionproof Head D

BUS Head
Custom execution on request

10

TSM TEMPERETURE PROBE EQUIPED WITH 4/20mA TRANSMITTER

Technical data
-Temperature working range: -50 .. 450 C (warning !! T type thermocouple 400 C max.) -Accuracy: ANSI MC96.1/IEC 584 (thermocouple probes) DIN 43760/IEC 752/UNI 7937 (RTD probes) -Protection: IP55 -Electrical connection 1/2" gas -Indicate temperature output range -Power 18 .. 36 V -Output 4 .. 20 mA

LA

TERMOTECNICA
and Rtd's
Wiring

Thermoucoples

Model Model

M E

M G M H A B C D

M I E F

1xTC

Type and class of tolerances Hot junction type Sheath quality Fittings Length L (mm) Connecting head Transmitter type Type and class of tolerances
Thermocouples,tolerances according to Ansi GrI T J E K T J E K

1xPT100

Thermocouples,tolerances according to Ansi GrII


RTD pt100 OHM a 0 C 1 DIN RTD pt100 OHM a 0 C 1/2 DIN RTD pt100 OHM a 0 C 1/3 DIN RTD pt100 OHM a 0 C 1/5 DIN RTD pt100 OHM a 0 C 1/10 DIN

A T J E K 1 2 3 4 A B C D E

Fittings D Stainless steel Sheath diameter (mm) fittings for model 6 8 10 12 14 MG-MI 1/8 A 1/4 B B Thread F 3/8 C C C C 1/2 D D D D D Fittings D Stainless steel Sheath diameter (mm) compression fittings 6 8 10 12 14 for model MH 1/8 A 1/4 B B Thread F 3/8 C C C C 1/2 D D D D D Fittings D Brass compression Sheath diameter (mm) fittings for model 6 8 10 12 14 MH 1/8 A 1/4 B B Thread F 3/8 C C C C 1/2 D D D D D

Hot juntion type Thermocouple Ungrounded Graunded RTD One pt 100 a 2 wire One pt 100 a 3 wire

B 1 2 1 2

Sheath quality s.s Quality Aisi 304 Aisi 316

Connecting head

Transmitter type Spring loaded insert with DAT 100 transmitter Intrinsec safety Without intrinsec safety Intrinsec safety Without intrinsec safety Without intrinsec safety Without intrinsec safety

F S T R U V Z

Sheath diameter (mm) 4 5 6 8 10 12 14 1 2 3 B E F G A B C 4 5 6 7

DIN B Head

B Explosionproof Head D

Insert with DAT 100 transmitter Spring loaded insert with DAT 110 transmitter Insert with DAT 110 transmitter

BUS Head
Custom execution on request

11

REPLACEMENT FOR TSM TEMPERATURE PROBE

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model

M L

A B C

0 0 0

Technical data
-Temperature working range: -50 .. 450 C (warning !! T type thermocouple 400 C max.) -Accuracy: ANSI MC96.1/IEC 584 (thermocouple probes) DIN 43760/IEC 752/UNI 7937 (RTD probes)

Type and class of tolerances Hot junction type Sheath diameter Length L (mm)

Wiring

Type and class of tolerances Thermocouples,tolerances according to Ansi GrI T J E K T J E K

Thermocouples,tolerances according to Ansi GrII


RTD pt100 OHM a 0 C 1 DIN RTD pt100 OHM a 0 C 1/2 DIN RTD pt100 OHM a 0 C 1/3 DIN RTD pt100 OHM a 0 C 1/5 DIN RTD pt100 OHM a 0 C 1/10 DIN

A T J E K 1 2 3 4 A B C D E

1xTC

2xTC

1xPT100 3 wire

1xPT100 4 wire

2xPT100 3+3 wire

Hot juntion type Thermocouple Ungrounded (single element) Ungraunded (double elements) Graunded RTD One pt 100 a 2 wire One pt 100 a 3 wire One pt100 a 4 wire Two pt100 a 2 wire Two pt100 a 3 wire

B 1 4 2 1 2 3 4 5

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 304 8 Aisi316

C 4 5 6 8

Custom execution on request

12

REPLACEMENTS FOR TSM TEMPERATURE PROBE EQUIPED WITH 4/20mA TRANSMITTER

LA

TERMOTECNICA
and Rtd's
M T

Intrinsic safety model

T h e r m oM uSc o p l e s

Non intrinsic safety model

Model

A B C

D 0 0

Technical data
-Temperature working range: -50 .. 450 C (warning !! T type thermocouple 400 C max.) -Accuracy: ANSI MC96.1/IEC 584 (thermocouple probes) DIN 43760/IEC 752/UNI 7937 (RTD probes) -Protection: IP55 -Electrical connection 1/2" gas -Indicate temperature output range -Power 18 .. 36 V -Output 4 .. 20 mA

Type and class of tolerances Hot junction type Diameter sheath Length L (mm) Transmitter type

Type and class of tolerances Thermocouples,tolerances according to Ansi GrI T J E K T J E K

Thermocouples,tolerances according to Ansi GrII


RTD pt100 OHM a 0 C 1 DIN RTD pt100 OHM a 0 C 1/2 DIN RTD pt100 OHM a 0 C 1/3 DIN RTD pt100 OHM a 0 C 1/5 DIN RTD pt100 OHM a 0 C 1/10 DIN

A T J E K 1 2 3 4 A B C D E

Transmitter type Insert with DAT 100 transmitter Insert with DAT 110 transmitter Intrinsec safety Without intrinsec safety Without intrinsec safety

D S T V

Wiring

1xTC

1xPT100

Hot junction type Thermocouple Ungrounded (single element) RTD One pt 100 a 2 wire One pt 100 a 3 wire One pt100 a 4 wire

B 1 1 2 3

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 304 8 Aisi316

C 4 5 6 8

Custom execution on request

13

Mineral insulated series (MgO)


This section covers thermocouples and RTD probes produced using mineral insulated (Magnesium oxide MgO) cables. The wide choice of solutions available means that this series can be used in an extensive range of applications, able to cater to all designer requirements. The external protection tubes are available in A304, A316, INC600, A321, etc. Features such as the integrated connector(permanently connected to the probe) or with integrated cable, both pressure and vibration resistant, and the ease of installation assured by the many types of fastening solutions, mean that this series always offers the right solution to any type of requirement. The 0.5-mm to 8-mm diameter thermocouples with J E K T N S configuration cover a measurement range of between 200 to +1500C. The RTD probes (Pt100, Ni100, Pt1000), produced according to the REVERSE or END CAP technique, are available in a diameter range from 3 mm to 8 mm and are particularly suited for applications affected by vibrations.

THERMOCOUPLE

LA TERMOTECNICA

RTD' S PROBE

Tipical applications: Furnaces Heating plants Avionics-Auotmotive Engines


LA TERMOTECNICA, produce in according to internal higth quality standards, and in accordance with international standards :

UNI 7938 IEC 584 ANSI / DIN


Utilization of special productive plants as, microscopes, custom welding machines, micro-manipulators, and above all our high level staff, assure quality standard and precision. If requested we supply documentation and product certification.

MINERAL INSULATED THERMOCOUPLES(MgO ), WITH STANDARD TYPE COMPENSATED CONNECTOR

LA

TERMOTECNICA
and Rtd's
G A G B

Thermoucoples
With plastic connector (max 220 C) With ceramic connector (max 550 C)

Model

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: GA 220 C - GB 550 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Connection
Type and class of tolerances J E K N S R J E K N S R A J E K N S R 2 3 4 5 6 7
B I M E

Standard type thermocouple connector

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

Hot junction type Ungraunded Grounded Exposed

Sheath quality and diameter SS quality A i si 3 0 4 A i si 3 1 6 Inconel 600 2 A G Q 3 3.17 B C J I R S 4 D L T 4.5 E M U

C 6 F O Z

Sheath diameter(mm)

Execution custom on request

15

MINERAL INSULATED THERMOCOUPLES(MgO ), WITH STANDARD TYPE COMPENSATED CONNECTOR AND FIXED FITTING

LA

TERMOTECNICA
and Rtd's
G C G D

Thermoucoples
With plastic connector (max 220 C) With ceramic connector (max 550 C)

Model

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: GC 220 C - GD 550 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Type and class of tolerances J E K N S R J E K N S R

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

A J E K N S R 2 3 4 5 6 7

Hot junction type Ungrounded Grounded Exposed

B I M E

Connection
Standard type thermocouple connector

Sheath quality and diameter SS quality A i si 3 0 4 A i si 3 1 6 Inconel 600 2 A G Q 3 3.17 B C J I R S 4 D L T 4.5 E M U

C 6 F O Z

Sheath diameter(mm)

Model M F

0 0 0 0 0

Thread F Length L (mm)

T hread F
8 MA 10MA 1/8 Gas 1/4 Gas 3/8 Gas 1/2 Gas
Execution custom on request

A A B C D E F

16

MINERAL INSULATED THERMOCOUPLES(MgO ), WITH STANDARD TYPE COMPENSATED CONNECTOR AND COMPRESSION FITTING

LA

TERMOTECNICA
and Rtd's
G E G F

Thermoucoples
With plastic connector (max 220 C) With ceramic connector (max 550 C)

Model

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: GE 220 C - GF 550 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Connection
Type and class of tolerances J E K N S R J E K N S R A J E K N S R 2 3 4 5 6 7
B I M E

Standard type thermocouple connector

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

Hot junction type Ungrounded Grounded Exposed

Sheath quality and diameter SS quality A i si 3 0 4 A i si 3 1 6 Inconel 600 2 A G Q 3 3.17 B C J I R S 4 D L T 4.5 E M U

C 6 F O Z

Sheath diameter(mm)

Adapter fittings with ogive pag. 79

Execution custom on request

17

MINERAL INSULATED THERMOCOUPLES(MgO ), DOUBLE ELEMENT WITH STANDARD TYPE COMPENSATED CONNECTOR

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G G

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: 220 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Connection
Type and class of tolerances J E K N S R J E K N S R A J E K N S R 2 3 4 5 6 7
B I M E

Double standard type thermocouple connector

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

Hot junction type Ungrounded Grounded Exposed

Sheath quality and diameter SS quality A i si 3 0 4 A i si 3 1 6 Inconel 600 2 A G Q 3 3.17 B C J I R S 4 D L T 4.5 E M U

C 6 F O Z

Sheath diameter(mm)

Execution custom on request

18

MINERAL INSULATED THERMOCOUPLES(MgO ), DOUBLE ELEMENT WITH STANDARD TYPE COMPENSATED CONNECTOR AND FIXED FITTING

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G H

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: 220 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Type and class of tolerances J E K N S R J E K N S R

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

A J E K N S R 2 3 4 5 6 7

Hot junction type Ungrounded Grounded Exposed

B I M E

Connection
Double standard type thermocouple connector

Sheath quality and diameter SS quality A i si 3 0 4 A i si 3 1 6 Inconel 600 2 A G Q 3 3.17 B C J I R S 4 D L T 4.5 E M U

C 6 F O Z

Sheath diameter(mm)

Model M F

0 0 0 0 0

Thread F Length L (mm)

T hread F
8 MA 10MA 1/8 Gas 1/4 Gas 3/8 Gas 1/2 Gas
Execution custom on request

A A B C D E F

19

MINERAL INSULATED THERMOCOUPLES(MgO ), DOUBLE ELEMENT WITH STANDARD TYPE COMPENSATED CONNECTOR AND COMPRESSION FITTING

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G I

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: 220 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Connection
Type and class of tolerances J E K N S R J E K N S R A J E K N S R 2 3 4 5 6 7
B I M E

Double standard type thermocouple connector

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

Hot junction type Ungrounded Grounded Exposed

Sheath quality and diameter SS quality A i si 3 0 4 A i si 3 1 6 Inconel 600 2 A G Q 3 3.17 B C J I R S 4 D L T 4.5 E M U

C 6 F O Z

Sheath diameter(mm)

Adapter fittings with ogive pag. 79

Execution custom on request

20

MINERAL INSULATED THERMOCOUPLES (Mgo ), WITH MINIATURE TYPE COMPENSATED CONNECTOR

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G L

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: 220 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Connection
Type and class of tolerances J E K N S R J E K N S R A J E K N S R 2 3 4 5 6 7

Miniature type thermocouple connector

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

Hot junction type Ungrounded Grounded Exposed

B I M E

Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600

Sheath diameter(mm) 0,5 1 1.5 2 3 3.17

A B C E F G H K J L M N O P Q S T U

Custom executions on request

21

MINERAL INSULATED THERMOCOUPLES (Mgo ),WITH MINIATURE TYPE COMPENSATED CONNECTOR AND FIXED FITTING

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G M

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: 220 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Type and class of tolerances J E K N S R J E K N S R

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

A J E K N S R 2 3 4 5 6 7

Hot junction type Ungrounded Grounded Exposed

B I M E

Connection
Miniature type thermocouple connector

Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600

Sheath diameter(mm) 0,5 1 1.5 2 3 3.14

A B C E F G H K J L M N O P Q S T U

Hot junction type Ungrounded Grounded Exposed

B I M E

Model M F

0 0 0 0 0

Thread F Length L (mm)

T hread F
8 MA 10MA 1/8 Gas 1/4 Gas 3/8 Gas 1/2 Gas
Custom execution on request

A A B C D E F

22

MINERAL INSULATED THERMOCOUPLES (Mgo ), WITH MINIATURE TYPE COMPENSATED CONNECTOR AND COMPRESSION FITTING

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G N

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: 220 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Connection
Type and class of tolerances J E K N S R J E K N S R A J E K N S R 2 3 4 5 6 7

Miniature type thermocouple connector

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

Hot junction type Ungrounded Grounded Exposed

B I M E

Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600

Sheath diameter(mm) 0,5 1 1.5 2 3 3.14

A B C E F G H K J L M N O P Q S T U

Adapter fittings with ogive pag. 79


Custom executions on request

23

MINERAL INSULATED THERMOCOUPLES (Mgo ), DOUBLE ELEMENT WITH MINIATURE TYPE COMPENSATED CONNECTOR

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G O

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: 220 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Connection
Type and class of tolerances J E K N S R J E K N S R A J E K N S R 2 3 4 5 6 7

Double miniature type thermocouple connector

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

Hot junction type Ungrounded Grounded Exposed


Sheath quality and diameter

B I M E
C

Sheath diameter(mm) SS quality 3 3.17 4 E F G A i si 3 0 4 L M N A i si 3 1 6 S T U Inconel 600

Custom execution on request

24

MINERAL INSULATED THERMOCOUPLES (Mgo ), DOUBLE ELEMENT WITH MINIATURE TYPE COMPENSATED CONNECTOR AND FIXED FITTING

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G P

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: 220 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Type and class of tolerances J E K N S R J E K N S R

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

A J E K N S R 2 3 4 5 6 7

Hot junction type Ungrounded Grounded Exposed


Sheath quality and diameter

B I M E
C

Connection
Double miniature type thermocouple connector

Sheath diameter(mm) SS quality 3 3.17 4 E F G A i si 3 0 4 L M N A i si 3 1 6 S T U Inconel 600

Hot junction type Ungrounded Grounded Exposed

B I M E

Model M F

0 0 0 0 0

Thread F Length L (mm)

T hread F
8 MA 10MA 1/8 Gas 1/4 Gas 3/8 Gas 1/2 Gas
Custom executions on request

A A B C D E F

25

MINERAL INSULATED THERMOCOUPLES (Mgo ), DOUBLE ELEMENT WITH MINIATURE TYPE COMPENSATED CONNECTOR AND COMPRESSION FITTING

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G Q

A B C

0 0

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of connector use: 220 C

Type and class of tolerances Hot junction type Sheath quality Length L (mm)

Connection
Type and class of tolerances J E K N S R J E K N S R A J E K N S R 2 3 4 5 6 7

Double miniature type thermocouple connector

Thermocouple,tolerances according to Ansi GrI

Thermocouple,tolerances according to Ansi GrII

Hot junction type Ungrounded Grounded Exposed


Sheath quality and diameter

B I M E
C

Sheath diameter(mm) SS quality 3 3.17 4 E F G A i si 3 0 4 L M N A i si 3 1 6 S T U Inconel 600

Adapter fittings with ogive pag. 79


Custom execution on request

26

THERMOCOUPLES MINERAL INSULATED (MgO) SERIES WITH INTEGRATED EXTENSION CABLE

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model H A
Type and class of tolerances Extension cable Hot junction type Sheath quality and diameter Length L (mm) (MgO) Lenght L1 (dm) (extension cable)

A B C D

Type and class of tolerances T J E K N S R T J E K N S R

Thermocouple,tolerances according to Ansi GrII

Thermocouple,tolerances according to Ansi GrI

A T J E K N S R 1 2 3 4 5 6 7

Hot junction type Ungrounded Grounded Exposed


Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600 1 A K Q

C I M E
D

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.22 mm2 ,insulation teflon/braided tinned copper/teflon 2x0.25 mm2 ,insulation braided glass/braided glass/braided tinned copper

B A B C

Sheath diameter(mm) 1.5 2 3 3.17 4 4.5 6 8 B D E F G H 4 J L M N O P 5 R T U W Z X 6 8

2x0.22 mm2 ,insulation extruded teflon/braided tinned copper/extruded D teflon 2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.19 mm2 ,insulation teflon/teflon 2x0.19 mm ,insulation siliconed glass braid/siliconed glass braid
2

E F G

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of cable use: in refernce of insulation material (check the cable technical notes) -Maximum temperature of transition use: 250 C

2x0.24 mm2 ,insulation extruded teflon/extruded teflon/braided tinned H copper 2x0.50 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.50 mm2 ,insulation pvc/pvc 2x0.24 mm ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm2 ,insulation teflon/teflon 2x0.19 mm2 ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm ,insulation teflon/braided tinnet copper/teflon 2x0.24 mm2 ,insulation siliconed rubber/siliconed rubber 2x0.19 mm2 ,insulation teflon/teflon
2 2

I L M N O P Q R

Connection
Stripped wire, respect polarity. (check color coding plan)

Custom executions on request

27

THERMOCOUPLES MINERAL INSULATED (MgO ) SERIES WITH INTEGRATED EXTENSION CABLE AND FIXED FITTING

LA

TERMOTECNICA
and Rtd's
Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of cable use: in refernce of insulation material (check the cable technical notes) -Maximum temperature of transition use: 250 C

Thermoucoples

Model H B
Type and class of tolerances Extension cable Hot junction type Sheath quality and diameter Length L (mm) (MgO) Lenght L1 (dm) (extension cable)

A B C D

Type and class of tolerances T J E K N S R T J E K N S R

Thermocouple,tolerances according to Ansi GrII

Thermocouple,tolerances according to Ansi GrI

A T J E K N S R 1 2 3 4 5 6 7

Hot junction type Ungrounded Grounded Exposed


Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600 1 A K Q

C I M E
D

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.22 mm2 ,insulation teflon/braided tinned copper/teflon 2x0.25 mm2 ,insulation braided glass/braided glass/braided tinned copper

B A B C

Sheath diameter(mm) 1.5 2 3 3.17 4 4.5 6 8 B D E F G H 4 J L M N O P 5 R T U W Z X 6 8

2x0.22 mm2 ,insulation extruded teflon/braided tinned copper/extruded D teflon 2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.19 mm2 ,insulation teflon/teflon 2x0.19 mm ,insulation siliconed glass braid/siliconed glass braid
2

E F G

Connection
Stripped wire, respect polarity. (check color coding plan)

2x0.24 mm2 ,insulation extruded teflon/extruded teflon/braided tinned H copper 2x0.50 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.50 mm2 ,insulation pvc/pvc

I L M N O P Q R

Model M F

0 0 0 0 0

2x0.24 mm ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm2 ,insulation teflon/teflon

Thread F Length L (mm)

2x0.19 mm2 ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm ,insulation teflon/braided tinnet copper/teflon
2

T hread F
8 MA 10MA 1/8 Gas 1/4 Gas 3/8 Gas 1/2 Gas
Custom executions on request

A A B C D E F

2x0.24 mm2 ,insulation siliconed rubber/siliconed rubber 2x0.19 mm2 ,insulation teflon/teflon

28

THERMOCOUPLES MINERAL INSULATED (MgO ) SERIES WITH INTEGRATED EXTENSION CABLE AND COMPRESSION FITTING

LA

TERMOTECNICA
and Rtd's
Adapter fittings with ogive pag. 79

Thermoucoples

Model H C
Type and class of tolerances Extension cable Hot junction type Sheath quality and diameter Length L (mm) (MgO) Lenght L1 (dm) (extension cable)

A B C D

Type and class of tolerances T J E K N S R T J E K N S R

Thermocouple,tolerances according to Ansi GrII

Thermocouple,tolerances according to Ansi GrI

A T J E K N S R 1 2 3 4 5 6 7

Hot junction type Ungrounded Grounded Exposed


Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600 1 A K Q

C I M E
D

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.22 mm2 ,insulation teflon/braided tinned copper/teflon 2x0.25 mm2 ,insulation braided glass/braided glass/braided tinned copper

B A B C

Sheath diameter(mm) 1.5 2 3 3.17 4 4.5 6 8 B D E F G H 4 J L M N O P 5 R T U W Z X 6 8

2x0.22 mm2 ,insulation extruded teflon/braided tinned copper/extruded D teflon 2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.19 mm2 ,insulation teflon/teflon 2x0.19 mm ,insulation siliconed glass braid/siliconed glass braid
2

E F G

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of cable use: in refernce of insulation material (check the cable technical notes) -Maximum temperature of transition use: 250 C

2x0.24 mm2 ,insulation extruded teflon/extruded teflon/braided tinned H copper 2x0.50 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.50 mm2 ,insulation pvc/pvc 2x0.24 mm ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm2 ,insulation teflon/teflon 2x0.19 mm2 ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm ,insulation teflon/braided tinnet copper/teflon 2x0.24 mm2 ,insulation siliconed rubber/siliconed rubber 2x0.19 mm2 ,insulation teflon/teflon
2 2

I L M N O P Q R

Connection
Stripped wire, respect polarity. (check color coding plan)

Custom executions on request

29

THERMOCOUPLES MINERAL INSULATED (MgO ) SERIES, WITH INTEGRATED EXTENSION CABLE AND CONNECTOR
Model
STANDARD CONNECTOR THREE PRONG

LA LA
Model

H D

TERMOTECNICA
CERAMIC STANDARD CONNECTOR

The rmoucoples H E
MINIATURE CONNECTOR

and

Rtd's

H F

TERMOTECNICA
and Rtd's
A B C D

STANSDARD CONNECTOR Therm oucoples H G

Type and class of tolerances Extension cable Hot junction type Sheath quality and diameter Length L (mm) (MgO) Lenght L1 (dm) (extension cable)

Type and class of tolerances T J E K N S R T J E K N S R

Thermocouple,tolerances according to Ansi GrII

Thermocouple,tolerances according to Ansi GrI

A T J E K N S R 1 2 3 4 5 6 7

Hot junction type Ungrounded Grounded Exposed


Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600 1 A K Q

C I M E
D

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.22 mm2 ,insulation teflon/braided tinned copper/teflon 2x0.25 mm2 ,insulation braided glass/braided glass/braided tinned copper

B A B C

Sheath diameter(mm) 1.5 2 3 3.17 4 4.5 6 8 B D E F G H 4 J L M N O P 5 R T U W Z X 6 8

2x0.22 mm2 ,insulation extruded teflon/braided tinned copper/extruded D teflon 2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.19 mm2 ,insulation teflon/teflon 2x0.19 mm ,insulation siliconed glass braid/siliconed glass braid
2

E F G

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of cable use: in refernce of insulation material (check the cable technical notes) -Maximum temperature of transition use: 250 C

2x0.24 mm2 ,insulation extruded teflon/extruded teflon/braided tinned H copper 2x0.50 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.50 mm2 ,insulation pvc/pvc 2x0.24 mm ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm2 ,insulation teflon/teflon 2x0.19 mm2 ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm ,insulation teflon/braided tinnet copper/teflon 2x0.24 mm2 ,insulation siliconed rubber/siliconed rubber 2x0.19 mm2 ,insulation teflon/teflon
2 2

I L M N O P Q R

Connection
Thermoouple connectors (see drow up)

Custom executions on request

30

THERMOCOUPLES MINERAL INSULATED (MgO ) SERIES, WITH INTEGRATED EXTENSION CABLE , CONNECTOR AND FIXED FITTING
Model
STANDARD CONNECTOR THREE PRONG

LA LA
Model

H H

TERMOTECNICA
CERAMIC STANDARD CONNECTOR

The H r I moucoples
MINIATURE CONNECTOR

and

Rtd's

H L

TERMOTECNICA
and Rtd's
Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of cable use: in refernce of insulation material (check the cable technical notes) -Maximum temperature of transition use: 250 C
Hot junction type Ungrounded Grounded Exposed
Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600 1 A K Q

STANSDARD CONNECTOR Therm oucoples

H M

A B C D

Type and class of tolerances Extension cable Hot junction type Sheath quality and diameter Length L (mm) (MgO) Lenght L1 (dm) (extension cable)

Type and class of tolerances T J E K N S R T J E K N S R

Thermocouple,tolerances according to Ansi GrII

Thermocouple,tolerances according to Ansi GrI

A T J E K N S R 1 2 3 4 5 6 7

C I M E
D

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.22 mm2 ,insulation teflon/braided tinned copper/teflon 2x0.25 mm2 ,insulation braided glass/braided glass/braided tinned copper

B A B C

Sheath diameter(mm) 1.5 2 3 3.17 4 4.5 6 8 B D E F G H 4 J L M N O P 5 R T U W Z X 6 8

2x0.22 mm2 ,insulation extruded teflon/braided tinned copper/extruded D teflon 2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.19 mm2 ,insulation teflon/teflon 2x0.19 mm ,insulation siliconed glass braid/siliconed glass braid
2

E F G

Connection
Thermoouple connectors (see drow up)

2x0.24 mm2 ,insulation extruded teflon/extruded teflon/braided tinned H copper 2x0.50 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.50 mm2 ,insulation pvc/pvc

I L M N O P Q R

Model M F

0 0 0 0 0

2x0.24 mm ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm2 ,insulation teflon/teflon

Thread F Length L (mm)

2x0.19 mm2 ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm ,insulation teflon/braided tinnet copper/teflon
2

T hread F
8 MA 10MA 1/8 Gas 1/4 Gas 3/8 Gas 1/2 Gas
Custom executions on request

A A B C D E F

2x0.24 mm2 ,insulation siliconed rubber/siliconed rubber 2x0.19 mm2 ,insulation teflon/teflon

31

THERMOCOUPLES MINERAL INSULATED (MgO ) SERIES, WITH INTEGRATED EXTENSION CABLE , CONNECTOR AND COMPRESSION FITTING
Model
STANDARD CONNECTOR THREE PRONG

LA LA
Model

H D N

TERMOTECNICA
CERAMIC STANDARD CONNECTOR

The rmoucoples H O E
MINIATURE CONNECTOR

and

Rtd's

H P F

TERMOTECNICA
and Rtd's
A B C D

STANSDARD CONNECTOR Therm oucoples H G

H Q

Type and class of tolerances Extension cable Hot junction type Sheath quality and diameter Length L (mm) (MgO) Lenght L1 (dm) (extension cable)

Adapter fittings with ogive pag. 79

Type and class of tolerances T J E K N S R T J E K N S R

Thermocouple,tolerances according to Ansi GrII

Thermocouple,tolerances according to Ansi GrI

A T J E K N S R 1 2 3 4 5 6 7

Hot junction type Ungrounded Grounded Exposed


Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600 1 A K Q

C I M E
D

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.22 mm2 ,insulation teflon/braided tinned copper/teflon 2x0.25 mm2 ,insulation braided glass/braided glass/braided tinned copper

B A B C

Sheath diameter(mm) 1.5 2 3 3.17 4 4.5 6 8 B D E F G H 4 J L M N O P 5 R T U W Z X 6 8

2x0.22 mm2 ,insulation extruded teflon/braided tinned copper/extruded D teflon 2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.19 mm2 ,insulation teflon/teflon 2x0.19 mm ,insulation siliconed glass braid/siliconed glass braid
2

E F G

Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Maximum temperature of cable use: in refernce of insulation material (check the cable technical notes) -Maximum temperature of transition use: 250 C

2x0.24 mm2 ,insulation extruded teflon/extruded teflon/braided tinned H copper 2x0.50 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.50 mm2 ,insulation pvc/pvc 2x0.24 mm ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm2 ,insulation teflon/teflon 2x0.19 mm2 ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm ,insulation teflon/braided tinnet copper/teflon 2x0.24 mm2 ,insulation siliconed rubber/siliconed rubber 2x0.19 mm2 ,insulation teflon/teflon
2 2

I L M N O P Q R

Connection
Thermoouple connectors (see drow up)

Custom executions on request

32

RTD' s PT100 MINERAL INSULATED (MgO ) SERIES, WITH INTEGRATED EXTENSION CABLE

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model H R

A B C D

Technical data
-Temperature working range: -80 .. +500 C -Accuracy: DIN 43710/IEC 548/UNI 7937 -Bending diameter: 4 x outside diameter, do not bend near sensing zone (50 mm from tip) -Maximum temperature of cable use: in refernce of insulation material (check the cable technical notes) -Maximum temperature of transition use: 250 C

Type and class of tolerances Extension cable Connection RTD Sheath diameter Length L (mm) (MgO) Length L1 (dm) (extension cable)

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

A A B C D E
B A B C

Connection RTD One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire

C 1 2 3 4 5
Pt100 Pt100

Wiring
stripped wires
red red red

Pt100

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.24 mm ,insulation siliconed rubber/siliconed rubber 2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.22 mm2 ,insulation extruded teflon/braided tinned copper/ extruded teflon 2x0.24 mm2,insulation teflon/teflon/braided tinned copper 2x0.22 mm ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.35 mm2 ,insulation braided glass/braided glass
2 2

Sheath diameter (mm) 3 3,17 4 4,5 6

D 1 2 5 3 4

white

withe

withe

2 wire
red red

3 wire
red

4 wire
red

D E F G H

Pt100

Pt100

Pt100

Pt100

white

white

white

white

2+2 wire

3+3 wire

Custom execution on request

33

RTD' s PT100 MINERAL INSULATED (MgO ) SERIES, WITH INTEGRATED EXTENSION CABLE AND FIXED FITTING

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model

H S

A B C D

Technical data
-Temperature working range: -80 .. +500 C -Accuracy: DIN 43710/IEC 548/UNI 7937 -Bending diameter: 4 x outside diameter, do not bend near sensing zone (50 mm from tip) -Maximum temperature of cable use: in refernce of insulation material (check the cable technical notes) -Maximum temperature of transition use: 250 C

Type and class of tolerances Extension cable Connection RTD Diameter sheath Length L (mm) (MgO2) Length L1(dm) (extension cable)

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

A A B C D E
B A B C

Connection RTD One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire

C 1 2 3 4 5
Pt100 Pt100

Wiring
stripped wires
red red red

Pt100

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.24 mm ,insulation siliconed rubber/siliconed rubber 2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.22 mm2 ,insulation extruded teflon/braided tinned copper/ extruded teflon 2x0.24 mm2,insulation teflon/teflon/braided tinned copper 2x0.22 mm2 ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.35 mm2 ,insulation braided glass/braided glass
2

Sheath diameter (mm) 3 3,17 4 4,5 6

D 1 2 5 3 4

white

withe

withe

2 wire
red red

3 wire
red

4 wire
red

D E F G H
Thread F Length L (mm)

Pt100

Pt100

Pt100

Pt100

white

white

white

white

2+2 wire

3+3 wire

Model M F

0 0 0 0 0

T hread F
8 MA 10MA 1/8 Gas 1/4 Gas 3/8 Gas 1/2 Gas
Custom execution in request

A A B C D E F

34

RTD' s PT100 MINERAL INSULATED (MgO ) SERIES, WITH INTEGRATED EXTENSION CABLE AND COMPRESSION FITTING

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model H T

A B C D

Technical data
-Temperature working range: -80 .. +500 C -Accuracy: DIN 43710/IEC 548/UNI 7937 -Bending diameter: 4 x outside diameter, do not bend near sensing zone (50 mm from tip) -Maximum temperature of cable use: in refernce of insulation material (check the cable technical notes) -Maximum temperature of transition use: 250 C

Type and class of tolerances Extension cable Connection RTD Sheath diameter Length L (mm) (MgO2) Length L1 (dm) (extension cable)

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

A A B C D E
B A B C

Connection RTD One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire

C 1 2 3 4 5
Pt100 Pt100

Wiring
stripped wires
red red red

Pt100

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.24 mm ,insulation siliconed rubber/siliconed rubber 2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.22 mm2 ,insulation extruded teflon/braided tinned copper/ extruded teflon 2x0.24 mm2,insulation teflon/teflon/braided tinned copper 2x0.22 mm ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.35 mm2 ,insulation braided glass/braided glass
2 2

Sheath diameter (mm) 3 3,17 4 4,5 6

D 1 2 5 3 4

white

withe

withe

2 wire
red red

3 wire
red

4 wire
red

D E F G H

Pt100

Pt100

Pt100

Pt100

white

white

white

white

2+2 wire

3+3 wire

Adapter fittings with ogive pag. 79

Custom execution on request

35

RTD' s PT100 MINERAL INSULATED (MgO ) SERIES, WITH CONNECTOR TYPE LEMO "B" PHG

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G R

A B C D

0 0

Technical data
-Temperature working range: -80 .. +500 C -Accuracy: DIN 43710/IEC 548/UNI 7937 -Bending diameter: 4 x outside diameter, do not bend near sensing zone (50 mm from tip) -Maximum temperature of connector use: 250 C

Connector dimension Type and class of tolerances Connection RTD Sheath diameter Length L (mm) (MgO)

Connector dimension

Connection RTD One element, 2 wire One element, 3 wire

C 1 2 3 4 5

Wiring
PHG model, "LEMO" connector.

One element, 4 wire Two elements, 2 wire Two elements, 3 wire

Sheath diameter (mm) 3 3,17 4 4,5 6

D 1 2 5 3 4

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

B A B C D E

Custom execution in request

36

RTD' s PT100 MINERAL INSULATED (MgO ) SERIES, WITH CONNECTOR TYPE LEMO "B" PHG AND FIXED FITTING

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G S

A B C D

0 0

Technical data
-Temperature working range: -80 .. +500 C -Accuracy: DIN 43710/IEC 548/UNI 7937 -Bending diameter: 4 x outside diameter, do not bend near sensing zone (50 mm from tip) -Maximum temperature of connector use: 250 C

Connector dimension Type and class of tolerances Connection RTD Sheath diameter Length L (mm) (MgO )

Connector dimension

Connection RTD One element, 2 wire One element, 3 wire

C 1 2 3 4 5

Wiring
PHG model, "LEMO" connector.

One element, 4 wire Two elements, 2 wire Two elements, 3 wire

Sheath diameter (mm) 3 3,17 4 4,5 6

D 1 2 5 3 4

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

B A B C D E

Model M F

0 0 0 0 0

Thread F Length L (mm)

T hread F
8 MA 10MA 1/8 Gas 1/4 Gas 3/8 Gas 1/2 Gas
Custom execution on request

A A B C D E F

37

RTD' s PT100 MINERAL INSULATED (MgO ) SERIES, WITH CONNECTOR TYPE LEMO "B" PHG AND COMPRESSION FITTING

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model G T

A B C D

0 0

Technical data
-Temperature working range: -80 .. +500 C -Accuracy: DIN 43710/IEC 548/UNI 7937 -Bending diameter: 4 x outside diameter, do not bend near sensing zone (50 mm from tip) -Maximum temperature of connector use: 250 C

Connector dimension Type and class of tolerances Connection RTD Sheath diameter Length L (mm) (MgO)

Connector dimension

Connection RTD One element, 2 wire One element, 3 wire

C 1 2 3 4 5

Wiring
PHG model, "LEMO" connector.

One element, 4 wire Two elements, 2 wire Two elements, 3 wire

Sheath diameter (mm) 3 3,17 4 4,5 6

D 1 2 5 3 4

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

B A B C D E

Adapter fittings with ogive pag. 79

Custom execution in request

38

RTD' s PT100 MINERAL INSULATED (MgO) SERIES, WITH CONNECTOR TYPE AMPHENOL JMR13

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model H U

A B C D

0 0

Technical data
-Temperature working range: -80 .. +500 C -Accuracy: DIN 43710/IEC 548/UNI 7937 -Bending diameter: 4 x outside diameter, do not bend near sensing zone (50 mm from tip) -Maximum temperature of connector use: 200 C

Connector dimension Type and class of tolerances Connection RTD Sheath diameter Length L (mm) (MgO)

Dimension connector
A=13mm B=21mm Connection for 2 or 3 wire

Connection RTD One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire

C 1 2 3 4 5

Wiring
JMR13 model, "Amphenol" connector.

A=13mm B=21mm Connection fot 4 wire or two RTD 2 wire

Sheath diameter (mm) 3 3,17 4 4,5 6

D 1 2 5 3 4

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

B A B C D E

Custom execution on request

39

CONNECTING CABLES WITH CONNECTORS TYPE LEMO "B" FGG for use with RTD's models GR-GS-GT

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model H V

B 0 0 0 0 0 0

Technical data
-Temperature working range: PVC insulated cable 105 C/ Silicon rubber insulated cable 180 C/ glass braid insulation cable 400 C. -Maximum temperature of connector use: 250 C

Extension cable Length L (dm) Connector dimension

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.24 mm2 ,insulation siliconed rubber/siliconed rubber

A A B

Connector dimension

2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned C co p p e r

Custom execution on request

40

CONNECTING CABLES WITH CONNECTORS TYPE AMPHENOL JMSP13/JMLP13 for use with RTD's model HU

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model

H Z

B 0 0 0 0 0 0

Technical data
-Temperature working range: PVC insulated cable 105 C/ Silicon rubber insulated cable 180 C/ glass braid insulation cable 400 C. -Maximum temperature of connector use: 200 C

Extension cable Length L (dm) Connector dimension

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.24 mm2 ,insulation siliconed rubber/siliconed rubber

A A B

2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned C co p p e r

Connector dimension

A=12.7

A=12.7

A=12.7

A=12.7

Custom execution on request

41

MINERAL INSULATED THERMOCOUPLES (MgO) SERIES, WITH CONNECTING HEAD


Model G U

LA

TERMOTECNICA
and Rtd's

TG hV ermoucoples

LA
Model

G Z

TERMOTECNICA
and Rtd's
Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Protection: IP55 -Electrical connection 1/2" gas
T J E K N T J E K N A T J E K N 1 2 3 4 5

Thermoucoples
G K A B C 0 0

Type and class of tolerances Hot junction type Sheath quality and diameter Length L (mm)
Type and class of tolerances

Hot junction type Single Ungraunded Graunded Exposed 1 2 3

B Double 6 7 8
C 6 G O Z 4 8 1 2 3 5

Wiring

Thermocouple,tolerances according to Ansi GrI

Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600 Aisi 310 3 3.17 4 4.5 B C D E J I L M R S T U P Q V W

Thermocouple,tolerances according to Ansi GrII

1xTC

2xTC

Sheath diameter (mm)

Custom execution on request

42

MINERAL INSULATED THERMOCOUPLES (MgO) SERIES, WITH CONNECTING HEAD AND FIXED FITTING
Model G X

LA

TERMOTECNICA
and Rtd's

TG hY ermoucoples

LA
Model

G J

TERMOTECNICA
and Rtd's
Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Protection: IP55 -Electrical connection 1/2" gas
T J E K N T J E K N A T J E K N 1 2 3 4 5

Thermoucoples
G W A B C 0 0

Type and class of tolerance Hot junction type Sheath quality and diameter Length L in mm
Type and class of tolerances

Hot junction type Single Ungraunded Graunded Exposed 1 2 3

B Double 6 7 8
C 6 G O Z 4 8 1 2 3 5

Wiring

Thermocouple,tolerances according to Ansi GrI

Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600 Aisi 310 3 3.17 4 4.5 B C D E J I L M R S T U P Q V W

Thermocouple,tolerances according to Ansi GrII

Sheath diameter (mm)

1xTC

2xTC

Model M F

0 0 0 0 0

Thread F Length L (mm)

T hread F
8 MA 10MA 1/8 Gas 1/4 Gas 3/8 Gas 1/2 Gas

A A B C D E F

Custom execution on request

43

MINERAL INSULATED THERMOCOUPLES (MgO) SERIES, WITH CONNECTING HEAD AND COMPRESSION FITTING
Model G 1

LA

TERMOTECNICA
and Rtd's

TG h2 ermoucoples

LA
Model

G 3

TERMOTECNICA
and Rtd's
Technical data
-Temperature working range: In reference of thermocouple type and diameter. (check technical notes) -Accuracy: ANSI MC96.1/IEC 584 -Bending diameter: 4 x outside diameter -Protection: IP55 -Electrical connection 1/2" gas
T J E K N T J E K N A T J E K N 1 2 3 4 5

Thermoucoples
G 4 A B C 0 0

Type and class of tolerance Hot junction type Sheath quality and diameter Length L in mm
Type and class of tolerances

Hot junction type Single Ungraunded Graunded Exposed 1 2 3

B Double 6 7 8
C 6 G O Z 4 8 1 2 3 5

Wiring

Thermocouple,tolerances according to Ansi GrI

Sheath quality and diameter SS quality Aisi 304 Aisi 316 Inconel 600 Aisi 310 3 3.17 4 4.5 B C D E J I L M R S T U P Q V W

Thermocouple,tolerances according to Ansi GrII

1xTC

2xTC

Sheath diameter (mm)

Adapter fittings with ogive pag. 79

Custom execution on request

44

RTD' s (PT100) MINERAL INSULATED (MgO ) SERIES, WITH CONNECTING HEAD

LA

Model G 5

TERMOTECNICA
and Rtd's

TG h6 ermoucoples

LA
Model

G 7

TERMOTECNICA
and Rtd's
Technical data
-Temperature working range: -80 .. +500 C -Accuracy: DIN 43710/IEC 548/UNI 7937 -Bending diameter: 4 x outside diameter, do not bend near sensing zone (50 mm from tip) -Protection: IP55 -Electrical connection 1/2" gas
A A B C D E
B 1 2 3 4 5
C

Thermoucoples
G 8 A B C 0 0

Type and class of tolerance Connection RTD Sheath quality and diameter Length L in mm

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

Wiring

Connection RT D One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire
Sheath quality and diameter

1xPT100 3 wire

1xPT100 4 wire

2xPT100 3+3 wire

Sheath diameter(mm) SS quality 3 3.17 4 6 1 2 3 4 A i si 3 0 4

Custom execution on request

45

RTD' s (PT100) MINERAL INSULATED (MgO ) SERIES, WITH CONNECTING HEAD AND FIXED FITTING
Model H Z

LA

TERMOTECNICA
and Rtd's

Th ermoucoples H K

LA
Model

H X

TERMOTECNICA
and Rtd's
Technical data
-Temperature working range: -80 .. +500 C -Accuracy: DIN 43710/IEC 548/UNI 7937 -Bending diameter: 4 x outside diameter, do not bend near sensing zone (50 mm from tip) -Protection: IP55 -Electrical connection 1/2" gas
A A B C D E
B 1 2 3 4 5
Sheath quality and diameter C

Thermoucoples
H J A B C 0 0

Type and class of tolerance Connection RTD Sheath quality and diameter Length L in mm

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

Wiring

Sheath diameter(mm) SS quality 3 3.17 4 6 1 2 3 4 A i si 3 0 4

Connection RT D One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire

1xPT100 3 wire

1xPT100 4 wire

Model M F

0 0 0 0 0

2xPT100 3+3 wire

Thread F Length L (mm)

T hread F
8 MA 10MA 1/8 Gas 1/4 Gas 3/8 Gas 1/2 Gas

A A B C D E F

Custom execution on request

46

RTD' s (PT100) MINERAL INSULATED (MgO ) SERIES, WITH CONNECTING HEAD AND COMPRESSION FITTING
Model H W

LA

TERMOTECNICA
and Rtd's

TH hY ermoucoples

LA
Model

H 1

TERMOTECNICA
and Rtd's
Technical data
-Temperature working range: -80 .. +500 C -Accuracy: DIN 43710/IEC 548/UNI 7937 -Bending diameter: 4 x outside diameter, do not bend near sensing zone (50 mm from tip) -Protection: IP55 -Electrical connection 1/2" gas
A A B C D E
B 1 2 3 4 5
C

Thermoucoples
H 2 A B C 0 0

Type and class of tollerance Connection RTD Sheath quality and diameter Length L in mm

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

Wiring

Connection RT D One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire
Sheath quality and diameter

1xPT100 3 wire

1xPT100 4 wire

2xPT100 3+3 wire

Sheath diameter(mm) SS quality 3 3.17 4 6 1 2 3 4 A i si 3 0 4

Adapter fittings with ogive pag. 79


Custom execution on request

47

FULL CABLE SERIES


In more than 20 years business in the sector, during which it has designed and produced hundreds of thousands of probes for the plastics industry and other 0 to 400C medium-low temperature applications, LA TERMOTECNICA has acquired unmatched experience and stepped up its quality and controls and is now able to propose an unmatched range of thermocouples and RTD probes. Customized sheath lenght Customized cable lenght Type of insulation: Glass braid, teflon, PVC silicon rubber Grounded or ungrounded hot junction Srew , clamp , spade, bayonet etc. fastening Type J,K,T,E or PT100, single or double element FULL CABLE (thermocouples or RTD' s) Thermocouples or RTD's for aerothermy Thermocouples or RTD's with bayonet fittings Micro-thermocouples

THERMOCOUPLE

LA TERMOTECNICA

RTD' S PROBE

The considerable variety of this series covers applications in many different sectors of industry:

Plastic industry Food processing equipment Residential and industrial heating plants Packaging equipment Refrigeration and conditioning Process industy Medical instrument and many other areas of applications

FULL CABLE STYLE THERMOCOUPLES, FOR TEMPERATURE UP TO 400 C (braided glass/braided glass/braided tinned copper).

FOR COMPRESSION FITTING SEE PAGE 78

LA
U B

Model U A

TERMOTECNICA
and Rtd's

Thermoucoples

LA
U C

TERMOTECNICA
and Rtd's
BRAZED SCREW (watertight)

ROTATING SCREW (GAS thread)

Thermoucoples

Model

A B C

Technical data
-Temperature working range: -50 .. 400 C -Accuracy: ANSI MC96.1/IEC 584

Type and class of tolerances Hot junction type Sheath quality Length L1 (dm) Fitting Length L (mm) Termination style

Connection
Stripped wire, respect polarity. (check color coding plan)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN T J K T J K

A T J K A C F

Hot junction type Ungrounded Grounded Exposed

B I M E

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 316 8 Aisi316

C 4 5 6 8

Fitting For model UA Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model UB-UC Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1
Termination style Stripping Standard male connector Standard female connector Miniature male connector Miniature female connector

D 0 1 2 3 1 2 3 4 5 6
E 0 A B C D

Execution custom on request

49

FULL CABLE STYLE THERMOCOUPLES, FOR TEMPERATURE UP TO 250 C (Teflon/braided tinned copper/Teflon).

FOR COMPRESSION FITTING SEE PAGE 78

LA
U E

Model U D

TERMOTECNICA
and Rtd's

Thermoucoples

LA
U F

TERMOTECNICA
and Rtd's
BRAZED SCREW (watertight)

ROTATING SCREW (GAS thread)

Thermoucoples

Model

A B C

Technical data
-Temperature working range: -50 .. 250 C -Accuracy: ANSI MC96.1/IEC 584

Type and class of tolerances Hot junction type Sheath quality Length L1 i (dm) Fitting Length L (mm) Termination style

Connection
Stripped wire, respect polarity. (check color coding plan)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN T J K T J K

A T J K A C F

Hot junction type Ungrounded Grounded Exposed

B I M E

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 316 8 Aisi316

C 4 5 6 8

Fitting For model UD Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model UE-UF Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1
Termination style Stripping Standard male connector Standard female connector Miniature male connector Miniature female connector

D 0 1 2 3 1 2 3 4 5 6
E 0 A B C D

Execution custom on request

50

FULL CABLE STYLE THERMOCOUPLES, FOR TEMPERATURE UP TO 180 C (siliconed rubber/siliconed rubber).

FOR COMPRESSION FITTING SEE PAGE 78

LA
U H

Model U G

TERMOTECNICA
and Rtd's

Thermoucoples

LA
U I

TERMOTECNICA
and Rtd's
BRAZED SCREW (watertight)

ROTATING SCREW (GAS thread)

Thermoucoples

Model

A B C

Technical data
-Temperature working range: -50 .. 180 C -Accuracy: ANSI MC96.1/IEC 584

Type and class of tolerances Hot junction type Sheath quality Length L1 (dm) Fitting Length L (mm) Termination style

Connection
Stripped wire, respect polarity. (check color coding plan)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN T J K T J K

A T J K A C F

Hot junction type Ungrounded Grounded Exposed

B I M E

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 316 8 Aisi316

C 4 5 6 8

Fitting For model UG Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model UH-UI Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1
Termination style Stripping Standard male connector Standard female connector Miniature male connector Miniature female connector

D 0 1 2 3 1 2 3 4 5 6
E 0 A B C D

Execution custom on request

51

FULL CABLE STYLE THERMOCOUPLES, FOR TEMPERATURE UP TO 100 C (PVC/braided tinned copper/PVC).

FOR COMPRESSION FITTING SEE PAGE 78

LA
V K

Model V Y

TERMOTECNICA
and Rtd's

Thermoucoples

LA
V 8

TERMOTECNICA
and Rtd's
BRAZED SCREW (watertight)

ROTATING SCREW (GAS thread)

Thermoucoples

Model

A B C

Technical data
-Temperature working range: -50 .. 100 C -Accuracy: ANSI MC96.1/IEC 584

Type and class of tolerances Hot junction type Sheath quality Length L1 (dm) Fitting Length L (mm) Termination style

Connection
Stripped wire, respect polarity. (check color coding plan)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN T J K T J K

A T J K A C F

Hot junction type Ungrounded Grounded Exposed

B I M E

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 316 8 Aisi316

C 4 5 6 8

Fitting For model VY Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model VK-V8 Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1
Termination style Stripping Standard male connector Standard female connector Miniature male connector Miniature female connector E 0 A B C D

D 0 1 2 3 1 2 3 4 5 6

Execution custom on request

52

FULL CABLE STYLE RTD' s, FOR TEMPERATURE UP TO 250 C (braided glass/braided glass/braided tinned copper).

FOR COMPRESSION FITTING SEE PAGE 78

LA
U M

Model U L

TERMOTECNICA
and Rtd's

Thermoucoples

LA
U N

TERMOTECNICA
and Rtd's
BRAZED SCREW (watertight)

ROTATING SCREW (GAS thread)

Thermoucoples

Model

A B C

Technical data
-Temperature working range: -50 .. 400 C -Accuracy: DIN 43710/IEC 751/UNI 7937

Type and class of tolerances Connection RTD Sheath quality Length L1 (dm) Fitting Length L (mm)

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

A A B C D E
B 1 2 3 4 5

Connection RT D One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 304 8 Aisi316

C 4 5 6 8

Fitting For model UL Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model UM-UN Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1

D 0 1 2 3 1 2 3 4 5
Pt100 Pt100 white withe

Wiring
stripped wires
red red red

Pt100

Pt100

Pt100

withe

2 wire
red red

3 wire
red

4 wire
red

6
white white

Pt100

Pt100

white

white

2+2 wire

3+3 wire

Execution custom on request

53

FULL CABLE STYLE RTD' s, FOR TEMPERATURE UP TO 250 C (Teflon/braided tinned copper/Teflon).

FOR COMPRESSION FITTING SEE PAGE 78

LA
U P

Model U O

TERMOTECNICA
and Rtd's

Thermoucoples

LA
U Q

TERMOTECNICA
and Rtd's
BRAZED SCREW (watertight)

ROTATING SCREW (GAS thread)

Thermoucoples

Model

A B C

Technical data
-Temperature working range: -50 .. 250 C -Accuracy: DIN 43710/IEC 751/UNI 7937

Type and class of tolerances Connection RTD Sheath quality Length L1 (dm) Fitting Length L (mm)

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

A A B C D E
B 1 2 3 4 5

Connection RT D One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 304 8 Aisi316

C 4 5 6 8

Fitting For model UO Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model UP-UQ Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1

D 0 1 2 3 1 2 3 4 5
Pt100 Pt100 white withe

Wiring
stripped wires
red red red

Pt100

Pt100

Pt100

withe

2 wire
red red

3 wire
red

4 wire
red

6
white white

Pt100

Pt100

white

white

2+2 wire

3+3 wire

Execution custom on request

54

FULL CABLE STYLE RTD' s, FOR TEMPERATURE UP TO 180 C (siliconed rubber/siliconed rubber).

FOR COMPRESSION FITTING SEE PAGE 79

LA
U J

Modell U X

TERMOTECNICA
and Rtd's

Thermoucoples

LA
U Y

TERMOTECNICA
and Rtd's
BRAZED SCREW (watertight)

ROTATING SCREW (GAS thread)

Thermoucoples

Modell

A B C

Technical data
-Temperature working range: -50 .. 180 C -Accuracy: DIN 43710/IEC 751/UNI 7937

Type and class of tolerances Connection RTD Sheath quality Length L1 (dm) Fitting Length L (mm)

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

A A B C D E
B 1 2 3 4 5

Connection RT D One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 304 8 Aisi316

C 4 5 6 8

Fitting For model UX Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model UJ-UY Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1

D 0 1 2 3 1 2 3 4 5
Pt100 Pt100 white withe

Wiring
stripped wires
red red red

Pt100

Pt100

Pt100

withe

2 wire
red red

3 wire
red

4 wire
red

6
white white

Pt100

Pt100

white

white

2+2 wire

3+3 wire

Execution custom on request

56

FULL CABLE STYLE RTD' s, FOR TEMPERATURE UP TO 100 C (PVC/braided tinned copper/PVC).

FOR COMPRESSION FITTING SEE PAGE 79

LA
U Z

Model U V

TERMOTECNICA
and Rtd's

Thermoucoples

LA
U K

TERMOTECNICA
and Rtd's
BRAZED SCREW (watertight)

ROTATING SCREW (GAS thread)

Thermoucoples

Model

A B C

Technical data
-Temperature working range: -50 .. 100 C -Accuracy: DIN 43710/IEC 751/UNI 7937

Type and class of tolerances Connection RTD Sheath quality Length L1 (dm) Fitting Length L (mm)

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

A A B C D E
B 1 2 3 4 5

Connection RT D One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 304 8 Aisi316

C 4 5 6 8

Fitting For model UV Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model UZ-UK Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1

D 0 1 2 3 1 2 3 4 5
Pt100 Pt100 white withe

Wiring
stripped wires
red red red

Pt100

Pt100

Pt100

withe

2 wire
red red

3 wire
red

4 wire
red

6
white white

Pt100

Pt100

white

white

2+2 wire

3+3 wire

Eexcution custom on request

55

FULL CABLE STYLE RTD' s WITH TRANSITION, FOR TEMERATURE UP TO 500 C (PVC/braided tinned copper/PVC).

FOR COMPRESSION FITTING SEE PAGE 79

LA
U 2

Model U 1

TERMOTECNICA
and Rtd's

Thermoucoples

LA
U 3 Model

TERMOTECNICA
and Rtd's
BRAZED SCREW (watertight)

ROTATING SCREW (GAS thread)

Thermoucoples

A B C

Technical data
-Temperature working range: -50 .. 180 C -Accuracy: DIN 43710/IEC 751/UNI 7937 -Maximum temperature of cable use: 100 C -Maximum temperature of transition use: 200 C

Type and class of tolerances Connection RTD Sheath quality Length L1 (dm) Fitting Length L (mm)

Type and class of tolerances


RTD pt100 OHM a 0 C 1 DIN RTD pt100 OHM a 0 C 1/2 DIN RTD pt100 OHM a 0 C 1/3 DIN RTD pt100 OHM a 0 C 1/5 DIN RTD pt100 OHM a 0 C 1/10 DIN

A A B C D E
B 1 2 3 4 5
C 3 B 4 5 6 8

Connection RT D One element a 2 wire One element a 3 wire One element a 4 wire Two element a 2 wire Two element a 3 wire
Sheath diameter (mm) 3 Aisi 304 3,17 Aisi 304 4 Aisi 304 4,5 Aisi 304 6 Aisi 304 8 Aisi316

Fitting For model U1 Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model U2-U3 Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1

D 0 1 2 3 1 2 3 4 5
Pt100 Pt100 white withe

Wiring
stripped wires
red red red

Pt100

Pt100

Pt100

withe

2 wire
red red

3 wire
red

4 wire
red

6
white white

Pt100

Pt100

white

white

2+2 wire

3+3 wire

Execution custom on request

57

FULL CABLE STYLE RTD' s WITH TRANSITION, FOR TEMERATURE UP TO 500 C (siliconed rubber/siliconed rubber).

FOR COMPRESSION FITTING SEE PAGE 79

LA
U 5

Model U 4

TERMOTECNICA
and Rtd's

Thermoucoples

LA
U 6

TERMOTECNICA
and Rtd's
BRAZED SCREW (watertight)

ROTATING SCREW (GAS thread)

Thermoucoples

Model

A B C

Technical data
-Temperature working range: -50 .. 180 C -Accuracy: DIN 43710/IEC 751/UNI 7937 -Maximum temperature of cable use: 180 C -Maximum temperature of transition use: 200 C

Type and class of tolerances Connection RTD Sheath quality Length L1 (dm) Fitting Length L (mm)

Type and class of tolerances


RTD pt100 OHM a 0 C 1 DIN RTD pt100 OHM a 0 C 1/2 DIN RTD pt100 OHM a 0 C 1/3 DIN RTD pt100 OHM a 0 C 1/5 DIN RTD pt100 OHM a 0 C 1/10 DIN

A A B C D E
B 1 2 3 4 5
C 3 B 4 5 6 8

Connection RT D One element a 2 wire One element a 3 wire One element a 4 wire Two element a 2 wire Two element a 3 wire
Sheath diameter (mm) 3 Aisi 304 3,17 Aisi 304 4 Aisi 304 4,5 Aisi 304 6 Aisi 304 8 Aisi316

Fitting For model U4 Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model U5-U6 Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1

D 0 1 2 3 1 2 3 4 5
Pt100 Pt100 white withe

Wiring
stripped wires
red red red

Pt100

Pt100

Pt100

withe

2 wire
red red

3 wire
red

4 wire
red

6
white white

Pt100

Pt100

white

white

2+2 wire

3+3 wire

Execution custom on request

58

FULL CABLE STYLE RTD' s WITH TRANSITION, FOR TEMERATURE UP TO 500 C (braided glass/braided glass/braided tinned copper).

FOR COMPRESSION FITTING SEE PAGE 79

LA LA
U 9 U 8

Model U 7

TERMOTECNICA
and Rtd's

Thermoucoples

TERMOTECNICA
ROTATING SCREW (GAS thread)

Thermoucoples

and

Rtd's

BRAZED SCREW (watertight)

Model

A B C

Technical data
-Temperature working range: -50 .. 180 C -Accuracy: DIN 43710/IEC 751/UNI 7937 -Maximum temperature of cable use: 400 C -Maximum temperature of transition use: 200 C

Type and class of tollerances Connection RTD Sheath quality Length L1 in dm Fitting Length L in mm

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

A A B C D E
B 1 2 3 4 5
C 3 B 4 5 6 8

Connection RT D One element, 2 wire One element, 3 wire One element, 4 wire Two elements, 2 wire Two elements, 3 wire
Diameter sheath (mm) 3 Aisi 304 3,17 Aisi 304 4 Aisi 304 4,5 Aisi 304 6 Aisi 304 8 Aisi316

Fitting For model U7 Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model U8-U9 Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1

D 0 1 2 3 1 2 3 4 5
Pt100 Pt100 white withe

Wiring
stripped wires
red red red

Pt100

Pt100

Pt100

withe

2 wire
red red

3 wire
red

4 wire
red

6
white white

Pt100

Pt100

white

white

2+2 wire

3+3 wire

Execution custom on request

59

FULL CABLE STYLE PROBES, FOR AEROTHERMAL RELIEF UP TO 100 C (PVC/braided tinned copper/PVC).

FOR COMPRESSION FITTING SEE PAGE 79

LA LA
V C V B

Model V A

TERMOTECNICA
and Rtd's

Thermoucoples

TERMOTECNICA
ROTATING SCREW (GAS thread)

Thermoucoples

and

Rtd's

BRAZED SCREW (watertight)

Model

A B C

Technical data
-Temperature working range: -50 .. 100 C -Accuracy: ANSI MC96.1/IEC 584 (thermocouple probes) DIN 43760/IEC 752/UNI 7937 (RTD probes)

Type and class of tolerances Connection RTD Sheath quality Length L1 (dm) Fitting Length L (mm)

Type and class of tolerances Thermocouples,tolerances according to Ansi GrI Thermocouples,tolerances according to Ansi GrII
RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN

T J K T J K

A T J K 1 2 4 A B C D

Connection RT D One element , 2 wire One element , 3 wire One element , 4 wire Exposed junction (thermocouple)

B 1 2 3 4

Fitting For model VA Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model VB-VC Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1

D 0 1 2 3 1 2 3 4 5
Pt100 Pt100 white withe

Wiring
stripped wires
red red red

Pt100

Pt100

Pt100

withe

2 wire
red red

3 wire
red

4 wire
red

6
white white

Pt100

Pt100

white

white

2+2 wire
Sheath diameter (mm) 5 Aisi 304 6 Aisi 304 8 Aisi316 C 5 6 8

3+3 wire

Stripped wire, respect polarity. (check color coding plan)

Execution custom on request

60

FULL CABLE STYLE PROBES, FOR AEROTHERMAL RELIEF UP TO 200 C (siliconed rubber/siliconed rubber).

FOR COMPRESSION FITTING SEE PAGE 79

LA LA
T C T B

Model T A

TERMOTECNICA
and Rtd's

Thermoucoples

TERMOTECNICA
ROTATING SCREW (GAS thread)

Thermoucoples

and

Rtd's

BRAZED SCREW (watertight)

Model

A B C

Technical data
-Temperature working range: -50 .. 200 C -Accuracy: ANSI MC96.1/IEC 584 (thermocouple probes) DIN 43760/IEC 752/UNI 7937 (RTD probes)

Type and class of tolerances Connection RTD Sheath quality Length L1 (dm) Fitting Length L (mm)

Type and class of tolerances Thermocouples,tolerances according to Ansi GrI Thermocouples,tolerances according to Ansi GrII
RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN

T J K T J K

A T J K 1 2 4 A B C D

Connection RT D One element , 2 wire One element , 3 wire One element , 4 wire Exposed junction (thermocouple)

B 1 2 3 4

Fitting For model TA Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model TB-TC Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1

D 0 1 2 3 1 2 3 4 5
Pt100 Pt100 white withe

Wiring
stripped wires
red red red

Pt100

Pt100

Pt100

withe

2 wire
red red

3 wire
red

4 wire
red

6
white white

Pt100

Pt100

white

white

2+2 wire
Sheath diameter (mm) 5 Aisi 304 6 Aisi 304 8 Aisi316 C 5 6 8

3+3 wire

Stripped wire, respect polarity. (check color coding plan)

Execution custom on request

61

FULL CABLE STYLE PROBES, FOR AEROTHERMAL RELIEF UP TO 400 C (braided glass/braided glass/braided tinned copper).

FOR COMPRESSION FITTING SEE PAGE 79

LA LA
T N T M

Model T L

TERMOTECNICA
and Rtd's

Thermoucoples

TERMOTECNICA
ROTATING SCREW (GAS thread)

Thermoucoples

and

Rtd's

BRAZED SCREW (watertight)

Model

A B C

Technical data
-Temperature working range: -50 .. 400 C -Accuracy: ANSI MC96.1/IEC 584 (thermocouple probes) DIN 43760/IEC 752/UNI 7937 (RTD probes)

Type and class of tolerances Connection RTD Sheath quality Length L1 (dm) Fitting Length L (mm)

Type and class of tolerances Thermocouples,tolerances according to Ansi GrI Thermocouples,tolerances according to Ansi GrII
RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN

T J K T J K

A T J K 1 2 4 A B C D

Connection RT D One element , 2 wire One element , 3 wire One element , 4 wire Exposed junction (thermocouple)

B 1 2 3 4

Fitting For model TL Whitout fitting Brass compression fitting 1/8(gas thread) Brass compression fitting 1/4(gas thread) Brass compression fitting 3/8(gas thread) For model TM-TN Sainless steel compression fitting 1/8(gas thread) Sainless steel compression fitting 1/4(gas thread) Sainless steel compression fitting 3/8(gas thread) Sainless steel compression fitting 1/2(gas thread) Sainless steel compression fitting 3/4(gas thread) Sainless steel compression fitting M8x1

D 0 1 2 3 1 2 3 4 5
Pt100 Pt100 white withe

Wiring
stripped wires
red red red

Pt100

Pt100

Pt100

withe

2 wire
red red

3 wire
red

4 wire
red

6
white white

Pt100

Pt100

white

white

2+2 wire
Sheath diameter (mm) 5 Aisi 304 6 Aisi 304 8 Aisi316 C 5 6 8

3+3 wire

Stripped wire, respect polarity. (check color coding plan)

Execution custom on request

62

WALL MOUNTING PROBES, WITH 4/20 mA TRANSMITTER

LA

TERMOTECNICA
and Rtd's
Watertight aluminium protection Holes for mounting

Thermoucoples

Plastic protection with exposed element

Model H 5 Model A B C 0 0 0 0 0 0 0

Model H 6
Dati Tecnici
-Temperature range: -50 .. 120 C -Accuracy: DIN 43760/IEC 751/UNI 7937 -Wall mounting box IP54 -Dimensions: 60x80x38 mm -In case of transmission equiped vesion, indicate desired transmitter range. Power: 18 .. 32 V Output: 4 .. 20 mA

Type and class of tolerances Connection RTD Transmitter type

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

A A B C D E
B 1
white white red white

Wiring

Connection RT D One element , 2 wire One element , 3 wire One element , 4 wire Two elements , 2 wire
Transmitter type

2 3 4
C

2 wire

3 wire

red

4 wire

Without transmitter (screew connection) 0 Insert with DAT 100 transmitter Insert with DAT 110 transmitter Intrinsec safety Without intrinsec safety Without intrinsec safety S T
white

1xPT100
red

white

red

Pt100

Transmitter equiped Pt100 2 + 2 wire

Execution custom on request

63

red

Pt100

Pt100

Pt100

DUCT & PIPE MOUNTING AEROTHERMIC PROBES, WITH 4/20 mA TRANSMITTER

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model Model A B C D

H 7 E 0

H 8
Dati Tecnici
-Temperature range: -50 .. 120 C -Accuracy: DIN 43760/IEC 751/UNI 7937 -Wall mounting box IP54 -Dimensions: 60x80x38 mm -In case of transmission equiped vesion, indicate desired transmitter range. Power: 18 .. 32 V Output: 4 .. 20 mA

Type and class of tolerances Connection RTD Fitting Connecting head Lenght L (mm) Transmitter type

Type and class of tolerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN RTD pt100 1/10 DIN

A A B C D E
B 1 2 3 4

Transmitter type

Wiring

Without transmitter (screew connection) 0 Insert with DAT 100 transmitter Insert with DAT 110 transmitter Intrinsec safety Without intrinsec safety Without intrinsec safety S T V

Connection RT D One element , 2 wire One element , 3 wire One element , 4 wire Two elements , 2 wire

3 wire

4 wire

Fitting
Brass compression fitting 1/4 (gas thread) Brass compression fitting 3/8 (gas thread) Brass compression fitting 1/2 (gas thread)

C A B C 0
3+3 wire
transmitter equiped

Whitout fitting
Connecting head

DIN B Head

Mignon Head

Miniature Head

BUS Head

Execution custom on request

64

FULL CABLE STYLE THERMOCOUPLES, WITH MALE BAYONET FITTING FOR TEMPERATURE UP TO 400 C (braided glass/braided glass/braided tinned copper).

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model

U R

A B C

Technical data
-Temperature working range: -50 .. 400 C -Accuracy: ANSI MC96.1/IEC 584

Type and class of tolerance Hot junction type Sheath diameter Length L1 (dm) Thread F Lenght L (mm)

Connection
Stripped wire, respect polarity. (check color coding plan)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN T J K T J K

A T J K A C F
B I M E

Hot junction type Ungrounded Grounded Exposed

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 304 8 Aisi316
T hread F 1/4 Gas 12 MA 14 MB 12 MB

C 4 5 6 8
D A B C D

Esecuzioni speciali a richiesta

65

FULL CABLE STYLE THERMOCOUPLES, WITH FEMALE BAYONET FITTING FOR TEMPERATURE UP TO 400 C (braided glass/braided glass/braided tinned copper).

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model

U S

A B C

Technical data
-Temperature working range: -50 .. 400 C -Accuracy: ANSI MC96.1/IEC 584

Type and class of tolerance Hot junction type Sheath diameter Length L1 (dm) Thread F Lenght L (mm)

Connection
Stripped wire, respect polarity. (check color coding plan)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN T J K T J K

A T J K A C F
B I M E

Hot junction type Ungrounded Grounded Exposed

Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 304 8 Aisi316
T hread F 1/8 Gas 1/4 Gas 3/8 Gas M10x1 12 MA 14 MA 12 MB

C 4 5 6 8
D A B C D F G H

Execution custom on request

66

FULL CABLE STYLE RTD' s, WITH MALE BAYONET FITTING FOR TEMPERATURE UP TO 400 C (braided glass/braided glass/braided tinned copper).

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model

U W

A B C

Technical data
-Temperature working range: -50 .. 400 C -Accuracy: DIN 43710/IEC 751/UNI 7937

Type and class of tolerance Connection RTD Sheath diameter Length L1 (dm) Thread F Lenght L (mm)

Type and class of tollerances


RTD pt100 OHM a 0 C 1 DIN RTD pt100 OHM a 0 C 1/2 DIN RTD pt100 OHM a 0 C 1/3 DIN RTD pt100 OHM a 0 C 1/5 DIN

A A B C D

Wiring
stripped wires
red red

Connection RT D One element a 2 wire One element a 3 wire


Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 304 8 Aisi316
T hread F 1/4 Gas 12 MA 14 MB 12 MB

B 1 2
C 4 5 6 8
D A B C D

Pt100

Pt100

white

withe

2 wire

3 wire

Execution custom on request

67

FULL CABLE STYLE RTD' s, WITH FEMALE BAYONET FITTING FOR TEMPERATURE UP TO 400 C (braided glass/braided glass/braided tinned copper).

LA

TERMOTECNICA
and Rtd's

Thermoucoples

Model

U T

A B C

Technical data
-Temperature working range: -50 .. 400 C -Accuracy: DIN 43710/IEC 751/UNI 7937

Type and class of tolerance Connection RTD Sheath diameter Length L1 (dm) Thread F Lenght L (mm)

Type and class of tollerances


RTD pt100 1 DIN RTD pt100 1/2 DIN RTD pt100 1/3 DIN RTD pt100 1/5 DIN

A A B C D

Wiring
stripped wires
red red

Connection RT D One element , 2 wire One element , 3 wire


Sheath diameter (mm) 4 Aisi 304 5 Aisi 304 6 Aisi 304 8 Aisi316
T hread F 1/8 Gas 1/4 Gas 3/8 Gas M10x1 12 MA 14 MA 12 MB

B 1 2
C 4 5 6 8
D A B C D F G H

Pt100

Pt100

white

withe

2 wire

3 wire

Execution custom on request

68

FULL CABLE STYLE THERMOCOUPLES, WHIT BRASS SESING HEAD

LA TERMOTECNICA
Thermoucoples and Rtd's

Model

U U

C 0 0

Technical data
-Temperature working range: -50 .. 400 C -Accuracy: ANSI MC96.1/IEC 584

Type and class of tolerances Length L (dm) Thread F Length L1 (mm) Point type

Connection
Stripped wire, respect polarity. (check color coding plan)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN
T hread F 6 MA M 8x1 8 MA M 10x1 10 MA 1/8 GAS 1/4 GAS
Point type

T J K T J K

A T J K A C F
B A B C D E F G
C

Custom execution on request

69

STAINLESS STEEL THERMOWELLS FOR MgO SERIE PROBES

LA TERMOTECNICA
Thermoucoples and Rtd's

Model Model A

P H

P E

P R B 0

P G

P F
Technical data

Sheath quality Length L (mm) Length L1 (mm) Fittings or flanges


Sheath quality Diameter sheath (mm) S.S. Quality Aisi 446 Aisi 310 Aisi 310* Inconel 600 Inconel 600* A
3/8 20 1/2

-Temperature working range: 0 .. 1200 C max (warning !! in reference of thermocouple type and protecting tube material, check technical notes) -For select compatile sensors suitable for use with P series thermowells, consult catalogue in refernce of following models: GA-GB-GG-GV-GZ-GK

A B E H M

C F I N

D G L O

Flanges (UNI 2278 PN16) for model PF B A B C D Q 90 60 12 14 R 95 65 12 14

Fitting female for model PR-PG 1/2" 3/4" 1" 1" 1/4"

B 1 2 3 4

Fitting male for model PE 1/2" 3/4" 1"

B 1 2 3

Custom execution on request

70

CERAMIC THERMOWELLS FOR MgO SERIE PROBES

LA TERMOTECNICA
Thermoucoples and Rtd's

Model Model A

T H

T E

T R B 0

T G

T F
Technical data

Sheath quality Length L (mm) Length L1 (mm) Fittings or flanges


Sheath quality Rod Ceramic Ceramic diameter diameter 610 1 3/8 10 mm 2 20 mm 16 mm 3 1/2 17 mm A Ceramic 710 A B C

-Temperature working range: 0 .. 1600 C max (warning !! in reference of thermocouple type and protecting tube material, check technical notes) -For select compatile sensors suitable for use with P series thermowells, consult catalogue in refernce of following models: GA-GB-GG-GV-GZ-GK

Flanges (UNI 2278 PN16) for model T F B A B C D Q 90 60 12 14 R 95 65 12 14

Fitting female for model T R-T G 1/2" 3/4" 1" 1" 1/4"

B 1 2 3 4

Fitting male for model TE 1/2" 3/4" 1"

B 1 2 3

Custom execution on request

71

MICRO THERMOCOUPLES FOR TEMPERATURE UP TO 200 C

Model

LA TERMOTECNICA
W P

TW hQ ermoucoples and Rtd's

LA TERMOTECNICA
W R

Thermoucoples and Rtd's


W S
1 2 3 4

Model

A B

MODEL WP

0 0 0 0

Type and class of tolerances Hot juntion type Length L (cm) Dimension cable Termination style

MODEL WQ
Sheath diameter Lenght L1 (mm)

Sheath diameter (mm)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN T J K T J K

A T J K A C F
B I M E
C A B C
D 0 S M

1.5 (cable 30 AWG) 2 (cable 28 AWG) 2.5 (cable 24 AWG) 3 (cable 30 AWG)

A A B C D

MODEL WR
Washer type Washer diameter

A B 0 0

Hot junction type Ungrounded Grounded Exposed


Dimension cable 30 AWG 28 AWG 24 AWG
Termination style Outles wire Standard male connector Miniature male connector

Washer type Copper Stanless steel

A R I

Washer diameter For screw 3 ma For screw 4 ma For screw 5 ma For screw 6 ma For screw 8 ma For screw 10 ma

B A B C D E F

Technical data
-Temperature working range: -50 .. 200 C -Accuracy: ANSI MC96.1/IEC 584

MODEL WS
Length L (mm) Thread F
T hread F 3 ma 4 ma 5 ma 6 ma 8 ma

B 0

Connection
Stripped wire, respect polarity. (check color coding plan)

B A B C D E

Esecuzioni speciali a richiesta

72

MICRO THERMOCOUPLES FOR TEMPERATURE UP TO 100 C

Model

LA TERMOTECNICA
W L

TW hM ermoucoples and Rtd's

LA TERMOTECNICA
W N

Thermoucoples and Rtd's


W K Model A B C D
1 2 3 4

MODEL WL

0 0 0 0

Type and class of tolerances Hot juntion type Length L (cm) Dimension cable Termination style

MODEL WM
Sheath diameter Lenght L1 (mm)

Sheath diameter (mm)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN T J K T J K

A T J K A C F
B I M E
C A B C
D 0 S M

1.5 (cable 30 AWG) 2 (cable 28 AWG) 2.5 (cable 24 AWG) 3 (cable 30 AWG)

A A B C D

MODEL WN
Washer type Washer diameter

A B 0 0

Hot junction type Ungrounded Grounded Exposed


Dimension cable 30 AWG 28 AWG 24 AWG
Termination style Outles wire Standard male connector Miniature male connector

Washer type Copper Stanless steel

A R I

Washer diameter For screw 3 ma For screw 4 ma For screw 5 ma For screw 6 ma For screw 8 ma For screw 10 ma

B A B C D E F

Technical data
-Temperature working range: -50 .. 100 C -Accuracy: ANSI MC96.1/IEC 584

MODEL WK
Lenght L1 (mm) Thread F
T hread F 3 ma 4 ma 5 ma 6 ma 8 ma

B 0

Connection
Stripped wire, respect polarity. (check color coding plan)

B A B C D E

Custom execution on request

73

MICRO THERMOCOUPLES FOR TEMPERATURE UP TO 400 C

Model

LA TERMOTECNICA
W O

TW hT ermoucoples and Rtd's

LA TERMOTECNICA
W R

Thermoucoples and Rtd's


W V Model A B C D
1 2 3 4

MODEL WO

0 0 0 0

Type and class of tolerances Hot juntion type Length L (cm) Dimension cable Termination style

MODEL WT
Sheath diameter Lenght L1 (mm)

Sheath diameter (mm)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN T J K T J K

A T J K A C F
B I M E
C A B C
D 0 S M

1.5 (cable 30 AWG) 2 (cable 28 AWG) 2.5 (cable 24 AWG) 3 (cable 30 AWG)

A A B C D

MODEL WR
Washer type Washer diameter

A B 0 0

Hot junction type Ungrounded Grounded Exposed


Dimension cable 30 AWG 28 AWG 24 AWG
Termination style Outles wire Standard male connector Miniature male connector

Washer type Copper Stanless steel

A R I

Washer diameter For screw 3 ma For screw 4 ma For screw 5 ma For screw 6 ma For screw 8 ma For screw 10 ma

B A B C D E F

Technical data
-Temperature working range: -50 .. 400 C -Accuracy: ANSI MC96.1/IEC 584

MODEL WV
Lenght L1 (mm) Thread F
T hread F 3 ma 4 ma 5 ma 6 ma 8 ma

B 0

Connection
Stripped wire, respect polarity. (check color coding plan)

B A B C D E

Custom execution on request

74

MICRO THERMOCOUPLES FOR TEMPERATURE UP TO 250 C

Model

LA TERMOTECNICA
Z O Z T Th ermoucoples and Rtd's

LA TERMOTECNICA
Z R

Thermoucoples and Rtd's


Z V Model A B C D
1 2 3 4

MODEL ZO

0 0 0 0

Type and class of tolerances Hot juntion type Length L (cm) Dimension cable Termination style

MODEL ZT
Sheath diameter Lenght L1 (mm)

Sheath diameter (mm)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN T J K T J K

A T J K A C F
B I M E
C A B C
D 0 S M

1.5 (cable 30 AWG) 2 (cable 28 AWG) 2.5 (cable 24 AWG) 3 (cable 30 AWG)

A A B C D

MODEL ZR
Washer type Washer diameter

A B 0 0

Hot junction type Ungrounded Grounded Exposed


Dimension cable 30 AWG 28 AWG 24 AWG
Termination style Outles wire Standard male connector Miniature male connector

Washer type Copper Stanless steel

A R I

Washer diameter For screw 3 ma For screw 4 ma For screw 5 ma For screw 6 ma For screw 8 ma For screw 10 ma

B A B C D E F

Technical data
-Temperature working range: -50 .. 250 C -Accuracy: ANSI MC96.1/IEC 584

MODEL ZV
Lenght L1 (mm) Thread F
T hread F 3 ma 4 ma 5 ma 6 ma 8 ma

B 0

Connection
Stripped wire, respect polarity. (check color coding plan)

B A B C D E

Custom execution on request

75

FULL CABLE STYLE THERMOCOUPLES, FOR PIPES OR PLATES. TEMPERATURE UP TO 400 C

Model S T

Model P S

Model

A B

Type and class of tolerances Extension cable Lenght cable L1 (dm)

Type and class of tolerances Thermocouple,tolerances according to Ansi Thermocouple,tolerances according to DIN T J K T J K

A T J K A C F

Tipi di cavo
Sezione 2x0.22 isolamento pvc/schermo/pvc norme Sezione 2x0.22 isolamento teflon nastrato schermo/teflon nastrato Sezione 2x0.25 isolamento elettrovetro elettrovetro/schermo

B A B C

MODEL ST
Pipe diameter (mm)

0 0

Technical data
-Temperature working range: PVC insulated cable 105 C/ Silicon rubber insulated cable 180 C/ glass braid insulation cable 400 C. -Accuracy: ANSI MC96.1/IEC 584

MODEL PS
Lenght L (mm) Lenght L1 (mm) Lenght S (mm)

Connection
Stripped wire, respect polarity. (check color coding plan)

Esecuzioni speciali a richiesta

76

Accessories
THERMOCOUPLE RTD' S PROBE

LA TERMOTECNICA

In many cases, top performance depends on combining the temperature probe with the right accessories. LA TERMOTECNICA has therefore developed an ever more extensive and complete range of accessories, connectors, extensions, fasteners, converters, cables, etc. so as to always offer the right solution in terms of reliability, ease of use and sturdiness of the measurement system. In this section: Fittings Thermowells Extensions Connectors Cables

THERMOWELLS IN STAINLESS STEEL OR BRASS

LA LA

TERMOTECNICA
TUBE MADE

Thermoucoples
1

and

Rtd's
MACHINED MADE

TERMOTECNICA
and Rtd's
MACHINED MADE WITH REDUCED TIP
1

T3h e r m o u c o p l e s

P M

A B

C 0 0

Thread Diameter (mm) Length L (mm) Sheath quality

T hread Thread F 1/4 3/8 3/8 1/2 3/4 1/2 3/4 3/4 1/2 Thread F1 1/8 1/8 1/4 1/4 1/4 3/8 3/8 1/2 1/2

A A B C D E F G H I

Thermow ell diameters Outsi de di ameter Insi de di ameter (mm) (mm) 6 5 8 6 10 8 12 10 14 12 16 13 20 17

Sheath quality Brass Aisi 304 Aisi 316 Aisi 310 Inconel 600

A B C D E F G

C A B C D E

CUSTOM EXECUTION ON REQUEST

78

COMPRESSION FITTING

LA
F T

TERMOTECNICA
and Rtd's
A A B C C C 0

Thermoucoples

Fitting material Ogive material Probe diameter in 1/100 d imm Thread F

Fitting material Brass Nickel brass Inox stainless

A O O I

A T N N

Ogive material Brass Teflon Inox stainless

B I O T

T hread F 8 MA 1/8 GAS 1/4 GAS 3/8 GAS 1/2 GAS

C C C 8 M A 1 / 1 / 3 / 1 / 8 4 8 2

CUSTOM EXECUTION ON REQUEST

79

EXTENSION FOR THRMOCOUPLES, WITH INTEGRATED CONNECTORS

LA LA
Modello

TERMOTECNICA
Rtd's

Modello F 0 F 3

Thermoucop s4 a n d F l 1eF
F 2 F 5

TERMOTECNICA
Rtd's
A B 0 0 0 0

Thermoucop s7 a n d 6eF F l

Type and tolerance Extension cable Cable lenght in dm

Type and class of tolerance T J E K N S R

Thermocouple tolerance according to Ansi

A T J E K N S R

Extension cable
2x0.24 mm2 ,insulation pvc/braided tinned copper/pvc 2x0.22 mm2 ,insulation teflon/braided tinned copper/teflon 2x0.25 mm2 ,insulation braided glass/braided glass/braided tinned copper

B A B C

2x0.22 mm2 ,insulation extruded teflon/braided tinned copper/extruded D teflon 2x0.25 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.19 mm2 ,insulation teflon/teflon 2x0.19 mm ,insulation siliconed glass braid/siliconed glass braid
2

E F G

2x0.24 mm2 ,insulation extruded teflon/extruded teflon/braided tinned H copper 2x0.50 mm2 ,insulation braided glass/braided glass/ braided tinned copper 2x0.50 mm2 ,insulation pvc/pvc 2x0.24 mm ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm2 ,insulation teflon/teflon 2x0.19 mm2 ,insulation teflon/braided tinnet copper/teflon 2x0.35 mm ,insulation teflon/braided tinnet copper/teflon 2x0.24 mm2 ,insulation siliconed rubber/siliconed rubber 2x0.19 mm2 ,insulation teflon/teflon
2 2

I L M N O P Q R

CUSTOM EXECUTION ON REQUEST

80

CONNECTORS FOR THERMOCOUPLES

MALE THERMOCOUPLE CONNECTOR STANDARD VERSION: TYPE CODE K 28SK1LB J 24SJ1LB S 33SS1LB T 36ST1LB FEMALE THERMOCOUPLE CONNECTOR STANDARD VERSION: TYPE CODE K 30SK2LB J 25SJ2LB S 34SS2LB T 37ST2LB PANEL JACKS STANDARD VERSION TYPE K J S T

CODE 32SK4LB 27SJ4LB 35SS4LB 39ST4LB

MALE THERMOCOUPLE CONNECTOR MINIATURE VERSION: TYPE CODE K 12MK1LB J 07MJ1LB S 17MS1LB T 21MT1LB FEMALE THERMOCOUPLE CONNECTOR MINIATURE VERSION: TYPE CODE K 13MK2LB J 09MJ2LB S 18MS2LB T 22MT2LB PANEL JACKS MINIATURE VERSION TYPE K J S T

CODE 16MK4LB 11MJ4LB 20MS4LB 23MT4LB

CUSTOM EXECUTION ON REQUEST

81

CONNECTORS FOR THERMOCOUPLES

MALE THERMOCOUPLE CONNECTOR STANDARD VERSION

TYPE K J S T

CODICE 51SK1OM 71SJ1OM 73SS1OM 50ST1OM

FEMALE THERMOCOUPLE CONNECTOR STANDARD VERSION

TYPE K J S T

CODICE 40SK2OM 72SJ2OM 74SS2OM 70ST2OM

MALE THERMOCOUPLE CONNECTOR 3 PRONG

TYPE K J S T

CODICE 063K1OM 473J1OM 773S1OM 753T1OM

FEMALE THERMOCOUPLE CONNECTOR 3 PRONG

TYPE K J S T

CODICE 033K2OM 533J2OM 783S2OM 763T2OM

MALE THERMOCOUPLE CONNECTOR MINIATURE VERSION

TYPE K J S T TYPE K J S T TYPE K J S T TYPE K J S T


CUSTOM EXECUTION ON REQUEST

CODE 52MK1OM 64MJ1OM 68MS1OM 66MT1OM CODE 57MK2OM 65MJ2OM 69MS2OM 67MT2OM CODE 79CK1OM 81CJ1OM 85CS1OM 83CT1OM CODE 80CK1OM 82CJ1OM 86CS1OM 84CT1OM

FEMALE THERMOCOUPLE CONNECTOR MINIATURE VERSION

MALE THERMOCOUPLE CONNECTOR 3 PRONG MINIATURE

FEMALE THERMOCOUPLE CONNECTOR 3 PRONG MINIATURE

82

THERMOCOULE AND RTD' s CABLES

Insulation
Teflon/Teflon or Teflon/Teflon/Overbraid

Working temperature

Abrasion resistance

Flexibility

Water submission

Moisture resistance

Available for thermocouples

Available for RTD' s

--200 .. +250 C

Excellent

G ood

Excellent

Excellent

Yes

Yes

Siliconed rubber/Siliconed rubber.


--60 .. +200 C Fair G ood G ood G ood Yes Yes

PVC/PVC o PVC/PVC/Overbraid

--40 .. +105 C

G ood

Excellent

G ood

G ood

Yes

Yes

Glass/Glass/Overbraid

--60 .. +400 C

Poor

G ood

Poor

Poor

Yes

Yes

Glass/Glass

--60 .. +400 C

Poor

G ood

Poor

Poor

Yes

No

CUSTOM EXECUTION ON REQUEST

83

Thermocouple cables with teflon insulation


THERMOCOUPLES RTD' s PROBES
Excellent resistance to chemical and atmospheric agents High level resistance to high temperature High level resistance to abrasion even at high temperatures Non-flammable Operating range -70 .. +250 C General remarks

LA TERMOTECNICA

The use of fluoropolymers (Teflon) in cable insulation makes it possible to obtain an end product with excellent properties that remain constant in a broad range of temperatures with more or less unchanged physical characteristics. Mechanical and electrical resistance and resistance to chemical agents means that these cables can be used in conditions not compatible with most conventional cables.

Primary insulation teflon Conductor insulation teflon Color coding according to ANSI MC96.1
Type
J J J K K K

Dim.
3, 2x1, 8 2, 7x1, 6 1, 4x0, 8 3, 2x1, 8 2, 7x1, 6 3, 2x1, 8

Cond.
2x0, 35 24 AWG 30 AWG 2x0, 34 24 AWG 30 AWG

Product code
05 09EBRO 0PS 05 AIF2FO 0PW 05 91F2AO 0PW 05 74NBRO 0PS 05 B7O 2FO 0PW 05 65O 2AO 0PW

Description
J ANSI 2x0, 35 Tfe-Tfe J ANSI special 24 AWG Tfe-Tfe J ANSI special 30AWG Tfe-Tfe K ANSI special 2x0, 35 Tfe-Tfe K ANSI special 24 AWG Tfe-Tfe K ANSI special 30AWG Tfe-Tfe

Spool (mt. )
300 100/300 100/300 300 100/300 100/300

In stock availabe cables, custom execution on request

Type
J K

Dim.
3x2 3x2

Cond.
2x0, 24 2x2, 24

Product code
05 79EBIQ 1PS 05 80NBIQ 1PS

Primary insulation teflon Conductor insulation teflon Tinned copper overbraid Color coding in according to ANSI MC96.1 Descrption Spool (mt. )
J ANSI 2x0, 24 Tfe-Tfe-Sch K ANSI 2x0, 24 Tfe-Tfe-Sch 300 300

In stock available cables, custom execution on request

CUSTOM EXECUTION ON REQUEST

84

Thermocouple cables with teflon insulation


THERMOCOUPLES RTD' s PROBES
Primary insulation teflon Tinned copper overbraid Secondary insulation teflon Color coding acording to ANSI MC96.1 Description Spool (mt. )
J ANSI 2x0, 24 Tfe-Sch-Tfe K ANSI 2x0, 24 Tfe-Sch-Tfe 300 300

Tyte
J K

Dim.
d. 3, 2 d. 3, 2

Cond.
2x0, 24 2x2, 24

Product code
05 AFEBIP1TS 05 95NBIP1TS

LA TERMOTECNICA

In stock available cables, custom execution on request

Type
K

Dim.
d. 3, 5

Cond.
2x0, 24

Product code
05 ATO BIP7TS

Primary insulation teflon, alluminium steep, Nylon streep, tinned copper braid, secondary insulation teflon Color coding according to ANSI MC96.1 Description Spool (mt. )
J ANSI 2x0, 24 Tfe-Sch-Tfe 300

In stock available cables, custom execution on request

CUSTOM EXECUTION ON REQUEST

85

Thermocouple cables with fiberglass insulation


THERMOCOUPLES RTD' s PROBES
Excellent resistance to high temperatures Reduced weight and dimensions Also available with shielding Non-flammable Operating range - 30 .. + 400C General remarks

LA TERMOTECNICA

I Cables with fiberglass sheath insulation assure excellent resistance at high temperatures as they are able to operate in normal conditions at 400C for short periods or in static conditions up to 500C. As excellent resistance to abrasion cannot be guaranteed, models with metal protective sheath should be selected for particular applications.

Primary insulation, braided glass Secondary insulation, braided glass Tinned copper overbraid Color coding ANSI MC96.1/DIN 43710
Type
J J K K

Dim.
d. 3, 2 d. 4 d. 3, 2 d. 4

Cond.
2x0, 25 2x0, 50 2x0, 25 2x0, 50

CProduct code
05 14D BJM1TS 05 72D BLM1TS 05 59NBJM1TS 05 61NBLM1TS

Description
J D IN 2x0, 25 V. sil-V. sil-Sch J D IN 2x0, 50 V. sil-V. sil-Sch K ANSI 2x0, 25 V. sil-V. sil-Sch K ANSI 2x0, 50 V. sil-V. sil-Sch

Spool (mt. )
300 300 300 300

In stock available cables, custom execution on request

Primary insulation braided glass Secondary insulation braided glass Color coding according to ANSI MC96.1
Type
J J J K K K

Dim.
3x2 1, 8x1, 2 1, 2x0, 9 3x2 1, 8x1, 2 1, 2x0, 9

Cond.
2x0, 35 24 AWG 30 AWG 2x0, 34 24 AWG 30 AWG

Product code
05 11EBFI0PS 05 24E2FI0PW 05 66F2AI0PW 05 50N2FI0PS 05 49N2FI0PW 05 64O 2AI0PW

Description
J ANSI 2x0, 19 V. sil-V. sil J ANSI 24 AWG V. sil-V. sil J ANSI 30 AWG V. sil-V. sil K ANSI 2x0, 34 V. sil-V. sil K ANSI 24 AWG V. sil-V. sil K ANSI 30 AWG V. sil-V. sil

Spool (mt. )
300 100/300 100/300 300 100/300 100/300

In stock availabe cables, custom execution on request


CUSTOM EXECUTION ON REQUEST

86

Thermocouple cables with silicone rubber insulation


THERMOCOUPLES RTD' s PROBES
Excellent flexibility Good resistance to abrasion Compatibility with HVAC applications Self-extinguishing Operating range - 50 .. + 200C General remarks

LA TERMOTECNICA

Cables with silicone rubber insulation can be used in high temperature applications with continuous use up to 180-200C. These cables feature good resistance and high level flexibility even at temperatures of around 50C whereas brittleness and stiffening may occur at lower temperatures. These cables also feature fairly good resistance to chemical agents except for acids, alkalis and hydrocarbons.

Primary insulation silicone rubber Secondary insulation silicone rubber Color coding according to ANSI MC96.1/DIN 43710
Type
J K

Dim.
d. 4, 2 d. 4, 2

Cond.
2x0, 24 2x0, 24

product code
05 12D BIE0TS 05 70NBIE0TS

Description
J D IN 2x0, 24 G. sil-G. sil K ANSI 2x0, 24 G. sil-G. sil

Spool (mt. )
300 300

In stock available calbles, custom execution on request

CUSTOM EXECUTION ON REQUEST

87

Thermocouple cables with PVC insulation


THERMOCOUPLES RTD' s PROBES
Good flexibility Good resistance to abrasion Self-extinguishing Operating range - 50 .. + 105C

LA TERMOTECNICA

General remarks

Cables with PVC (polyvinylchloride) insulation are the ideal solution in almost all applications characterized by wiring in normal conditions. Despite everything, the PVC guarantees medium level performance as regards resistance to chemical and environmental agents combined with good mechanical strength and abrasion resistance.

Primary insulation, PVC Braided tinned copper Secondary insulation, PVC Color coding according to ANSI MC96.1
Type
J K

Dim.
d. 4, 2 d. 4, 2

Cond.
2x0, 24 2x0, 24

Product code
05 132EBIC1TS 05 57NBIC1TS

Description
J ANSI 2x0, 24 PVC-Sch-PVC K ANSI 2x0, 24 PVC-Sch-PVC

Spool (mt. )
300 300

In stock available cables, custom execution on request

CUSTOM EXECUTION ON REQUEST

88

Extention and/or compensating cables for thermocouples


THERMOCOUPLES RTD' s PROBES
For the installation of long wiring lines Available for J, K, R, S, B type thermocouples General remarks

LA TERMOTECNICA

Compensating cables are used to connect thermocouple sensors and although the alloys forming the thermo-electric pairs of each type of thermocouple are not used, they assure good transmission of the signal.

Primary insulation, PVC Secondary insulation, PVC Color coding according to DIN 43710
Type
JX WX

Dim.
7x4 7x4

Cond.
2x1, 3 2x1, 3

Product code
06 ARD BO B0PS 06 04ZBO B0PS

Descrizption
JX D IN 2x1, 3 PVC-PVC WX D IN 2x1, 3 PVC-PVC

Spool (mt. )
300 300

In stock available cables, custom execution on request

Primary insulation, braided galss Secondary insulation, braided glass Braided tinned copper Color coding according to DIN 43710
Type
WX S/R/B X

Dim.
d. 4, 1 4, 2x2, 9

Cond.
2x0, 50 2x1

Product code
06 06ZBLM1TS 06 02Q BNM1PS

Description
WX D IN 2x0, 5 V. sil-V. sil-Sch SX ANSI 2x1 V. sil-V. sil. Sch

Spool (mt. )
300 300

In stock available cables, custom execution on request

CUSTOM EXECUTION ON REQUEST

89

Temperature transmitters for thermocouples and RTD' s


THERMOCOUPLES RTD' s PROBES
Available inputs for RTD, TC, mV, V, mA ... Current or voltage output Galvanic insulation Easy setting by using PC High precision and stability Compatibilita elettromagnetica (marcatura CE) Available in version for in head or DIN rail mounting Is possible to supply custom configuration without add cost

LA TERMOTECNICA

Transitter/converter for thermocouples E J N K S T end RTD' s. Avaliable in two models, for DIN rail mounting or for connecting head. It is possible to connect probes directly to a PLC system whit current or voltage imputs (0-20 mA 4-20 mA 0.10 V). All signals availables with 2 or 3 wire tecnique, input output insulation up to 1500 V or intrinsec safety execution.

CUSTOM EXECUTION ON REQUEST

90

Programmable and linearized transmitter for PT100 DAT 1110


FEATURES PT100 input Two wire 420 mA linearized output Zero and span programmable by DIP SWITCH Good accuracy and performance stability Also available in F scale Conform to EMC standards - CE mark Suitable for mounting on DIN B connection heads Low cost APPLICATIONS Temperature monitoring and controlling in: - Process controls - Automation systems - Energy sources management

GENERAL INFORMATION
The two wire DAT1110 transmitter has been designed to give an output current signal of 420 mA; this signal is perfectly linear and proportional to the temperature detected by the PT100 sensor (IEC 751) connected to its input. The connection can be performed with two or three wires. The output current signal is supplied on the same two wires used to power the device. The user can program the full scale easily and quickly by means of four way DIP switch. The "zero" value can be varied between -50C to +50C and the span value can be programmed from 50C to 650C.The maximum accuracy and reliability are ensured for all the functions (conditioning, linearization, line resistance compensation and current transmission) thanks to the employement of highprecision and high-quality components and to the use of the SMD technology. The device, conform to the 89/336/EEC directives on electromagnetic compatibility, is housed in a rugged self-extinguishing plastic case suitable for direct mounting on the probe head. The device is available also in a different case version suitable for mounting on DIN rails.

TECHNICAL SPECIFICATIONS (Typical @ 25C and in the nominal conditions)


Input Type of sensor Zero Span Sensor current Input configuration Influence of line resistance Output Sensor interruption signaling Measuring current Current limitation Protection against polarity reversal Response time ( 10 to 90% of full scale) Warm-up time Performances Calibration inaccuracy Linearity error (inclusive of hysteresis, linearization error and variation of supply voltage) Electomagnetic Compatibility (EMC) Thermal drift Power supply voltage Operating temperature Storage temperature Relative humidity (non-condensing) Weight *: For lower f.s. this value must be proportionally increased. PT100 according to IEC 751 Programmable in the -50C to +50C range Programmable from 50C to 650C 1 mA two or three wires 0.05% of f.s./ for the maximum f.s.*(100

max. balanced on each wire)

Positive out-of-scale 420 mA, two wires about 35 mA 60 V reverse max 0.3 seconds 3 minutes

0.1% of full scale or 0.1C 0.15% of full scale According to EN50081-2 and EN50082-2 0.03% of full scale/C 10 32 V - 20 70 C - 40 100 C 0 90 % 35 grams

Custom execution on request

91

WORKING DIAGRAM

LOAD CHARACTERISTICS

OPERATING INSTRUCTIONS
The transmitter must be powered with a voltage ranging from 10 to 32 V, applied between the -V and +V terminals.The permissible Rload resistance, equivalent o that of the instruments applied in series to the voltage generator, must be determined as a function of the power supply voltage value and according to the load characteristic so that its value is covered by the working area. The connection of the sensor can be performed with two or three wires. The two-wire connection is performed by connecting the sensor to terminals no. 2 and no. 3 and connecting terminal no.1 to the terminal no. 2. The wiring diagram here below shows a three -wire connection. The scale range can be programmed in a quick and easy way: the span value must be set giving to the DIP switch a configuration according to the "Calibration Table" here below, then, after placing at the input a sample resistor of a value corresponding to zero scale, adjust the "zero" potentiometer so as to obtain a 4 mA indication, then, with a resistor of a value corresponding to the full scale, adjust the "span" potentiometer to a 20 mA indication. Repeat these adjustments until the requested accuracy is achieved.

WIRING DIAGRAM

CALIBRATION TABLE
Span values
SW3 SW4

RTD

2 3 1

<80C or <140F ON 80...200C or 140...360F ON 200... 250C or 360...450F OFF 250...650C or 450..1200F OFF

OFF ON OFF ON

Zero values (Per Span <200C or <360F) SW1 SW2


+V -V

+V RLoad

-50...-15C or -100...-33F -15...15C or -33...33F 15...50C or 33...100F Zero values

OFF OFF ON OFF ON ON

(Per Span >200C o >360F) SW1 SW2

-50...50C or -100...100F OFF OFF


PHYSICAL SIZE (measures in mm.)
ZERO

HOW TO ORDER:
1

SW

1
-V

DAT 1110 - PT100 - C


+V
0

4 SW

C or F

SPAN

7 33 43

24
EDIT.10.00-REV.00

La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

92

Programmable transmitter for thermocouple DAT 1120


FEATURES TC input from E, J, K, N, S, R, B e T type Two wire 420 mA voltage linear output Zero and span programmable by DIP SWITCH Good accuracy and performance stability Programmable for bothC & F scales One model cover both K & J TC type. Conform to EMC standards - CE mark Suitable for mounting on DIN B connection heads Low cost

APPLICATIONS Temperature monitoring and controlling in: - Process controls - Automation systems - Energy sources management

GENERAL INFORMATION
The two wire DAT1120 transmitter has been designed to give an output current signal of 420 mA; this signal is perfectly linear and proportional to the voltage generated by the thermocouple sensor connected to its input. The output current signal is supplied on the same two wires used to power the device. The user can program the full scale easily and quickly by means of four way DIP switch. The "zero" value can be varied between -50C to +50C or -100 to +100 F and the span value can be programmed following TC limits only.The maximum accuracy and reliability are ensured for all the functions (conditioning, cold junction compensation and current transmission) thanks to the employement of high precision and high-quality components and to the use of the SMD technology. The device, conform to the 89/336/EEC directives on electromagnetic compatibility, is housed in a rugged self-extinguishing plastic case suitable for direct mounting on the connection head.

TECHNICAL SPECIFICATIONS (Typical @ 25C and in the nominal conditions)


Input Type of sensor Zero Span Influence of line resistance Output Sensor interruption signaling Measuring current Current limitation Protection against polarity reversal Response time ( 10 to 90% of full scale) Warm-up time Performances Calibration inaccuracy Linearity error (inclusive of hysteresis and supply voltage variations) Electromagnetic Compatibility (EMC) Thermal drift Power supply voltage Operating temperature Storage temperature Relative humidity (non-condensing) Weight TC type K, J, S, N, E, T, B and R according to SIPT68 Programmable in the -50C to +50C range or -100F to 100F Programmable according to version table. 0,2 V /

Positive out of scale (< 3.5 mA on request) 420 mA, two wires about 35 mA 60 V reverse max 0.3 s. 3 minutes

0.1% of f.s. or 0.2C 0.1% of full scale According to EN50081-2 and EN50082-2 0.03% of full scale/C 12 32 V - 20 70 C - 40 100 C 0 90 % 35 grams

Custom execution on request

93

WORKING DIAGRAM

LOAD CHARACTERISTICS

- TC + TC

1 3 MAIN AMP . LINEARIZER +V -V

TWO WIRE TRANSMITTER COLD JUNCT. COMP .

OPERATING INSTRUCTIONS The transmitter must be powered with a voltage ranging from 12 to 32 V, applied between the -V and +V terminals.The permissible Rload resistance, equivalent to that of the instruments applied in series to the voltage generator, must be determined as a function of the power supply voltage value and according to the load characteristic so that its value is covered by the working area. DAT 1120 is available in 6 different versions, covering all common sensors types. For most common sensors a single unit cover 2 sensors, allowing substantial reduction of stocks. The scale range can be programmed in a quick and easy way: the span value must be setted giving the DIP switch a configuration according to the dedicated "Programming sheet" , then, after simulating at the input the zero scale, adjust the "zero" potentiometer so as to obtain a 4 mA indication, finally, simulating the full scale, adjust the "span" potentiometer to get a 20 mA indication. Repeat these adjustments until the requested accuracy is achieved. WIRING DIAGRAM

VERSION TABLE
+TC
3

Version
2 1

Sensor

Programmable Span
100 - 1400 C / 200 - 2500 F (K) 100 - 950 C / 200 - 1800 F (J) 650 - 1760 C / 1200 - 3200 F (R) 700 - 1760 C / 1290 - 3200 F (S) 100 - 350 C / 200 - 600 F 900 - 1820 C / 1600 - 3250 F 150 - 1350 C / 250 - 2400 F 50 - 1050 C / 100 - 1900 F

-TC

1 2 3

K&J R&S T B N E

+V

-V

+V RLoad

4 5 6

PHYSICAL SIZE (measures in mm.)


ZERO

3
4

2
1

HOW TO ORDER:

SW

1
-V

DAT 1120 - 1
+V
0

SW

SPAN

Version

7 33 43

24
EDIT.10.00-REV.00

La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

94

Two wire transmitter for thermocouple DAT 1030


FEATURES Thermocouple input, type E, J, K, N, S and T "Voltage linear" output (420 mA) High accuracy and linearity Available in both C & F scales Conform to EMC standards - CE mark Suitable for mounting on DIN B connection heads Low cost APPLICATIONS Temperature monitoring and controlling in: - Process controls - Automations systems - Energy source management

GENERAL INFORMATION
DAT 1030 is a two wire transmitter designed to give an output current signal of 420 mA which is proportional and perfectly linear with the voltage supplied by the thermocouple connected to its input. The cold junction compensation is performed inside it by a highly accurate and stable semiconductor temperature sensor. The output current signal is supplied on the same two wires used to power the device. The lack of linearization feature, available in the DAT 1015 model, makes this device compatible with data acquisition system which have an internal linearization software, allowing a further costs reduction. All features are realized with extreme accuracy and reliability thanks to the employment of high precision and quality components and the employment of the SMD manufacturing technology. The device, conform to the 89/336/EEC directives on electromagnetic compatibility, ishoused in a strong self extinguishing plastic case suitable for direct mounting in the probe connection head,. It is available also in a different case version suitable for mounting on DIN rails.

TECHNICAL SPECIFICATIONS ( Typical @ 25C and in the nominal conditions)


Input Sensor type Minimum input range Influence of line resistance Output Sensor interruption signaling Measuring current Current limitation Protection against polarity reversal Response time (dal 10 al 90% del f.s.) Warm up time Termocouple type K, J, S, N, T, and E according to SIPT68 15 mV 0.2 V/

Positive out-of-scale 420 mA, two wires Approx. 25 mA 60 V reverse max 0.3 s. 3 minutes.

Performances Calibration error 0.1% of f.s. or 0.2C. Non linearity error 0.1% of f.s. (inclusive of hysteresis, linearization error and supply voltage variations) Electomagnetic Compatibility (EMC) According to EN50081-2 and EN50082-2 Thermal drift 0.03% of f.s. /C Power supply voltage 12 32 V Operating temperature -20 70 C Storage temperature -40 100 C Relative humidity (non condensing) 0 90% Weight 35 grams

Custom execution on request

95

WORKING DIAGRAM

LOAD CHARATERISTIC

OPERATING INSTRUCTIONS The transmitter must be powered with a voltage ranging from 12 to 32 V, applied between the -V and +V terminals. The permissible Rload resistance to be applied in series to the voltage generator must be dimensioned as a function of the power supply voltage value and according to the load characteristic so that the value obtained is covered by the working area. The thermocouple must be connected between terminals no. 1 and no. 3. When a shielded cable is used, the shield must be connected to terminal no. 1.It is possible and easy to perform the calibration, if needed, just by operating on the zero and span adjustments: after imposing at the input a voltage of a value corresponding to zero scale, adjust the "zero" potentiometer so as to obtain a 4 mA indication, and then, after imposing a thermocouple voltage corresponding to the full scale, adjust the "span" potentiometer to a 20 mA indication. Repeat these adjustments until the requested accuracy is achieved. Note: When the calibration is accomplished without precision calibrators performing internal cold junction compensation, the value of the thermocouple voltage corresponding to the room temperature must be subtracted from the input voltage in order to compensate the cold junction. PHYSICAL DIMENSIONS (All measures in mm.)
ZERO

CONNECTION DIAGRAM

3
4

2
1
-V

+TC
3

2 1

-TC

HOW TO ORDER:

NOTE: Upon request and for apprecciable quantities is possible to custom engineer particular calibrations for non standard sensors or scale range

La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

+V

+V

-V

SPAN

+V RLoad

7 33 43

24

DAT 1030 - J - 0 300


Sensor type Scale range (To choose it, refer to the apposite list here at side) EDIZ.10.00-REV.00

96

Linearized two wire transmitter for PT100 DAT 1040


FEATURES PT100 input Linearized output (420 mA) Good accuracy and linearity Available in both C & F scales Conform to EMC standards - CE mark Suitable for mounting on DIN B connection heads Class V0 Polycarbonate case Low cost APPLICATIONS Temperature monitoring and control in: - Process controls - Automation systems - Energy source management

GENERAL INFORMATION
The two wire transmitter DAT 1040 has been designed to give an output current signal of 420 mA; this signal is perfectly linear and proportional to the temperature detected by the PT100 sensor (IEC 751) connected to its input. The connection can be performed with two or three wires. The output current signal is supplied on the same two wires used to power the device. This transmitter has been conceived to provide a reliable device with good precision at low cost. The maximum accuracy and reliability are ensured for all the functions (conditioning, linearization, line resistance compensation and current transmission) thanks to the employment of high-precision and high-quality components and the use of the SMD manufacturing technology. The device, conform to the 89/336/EEC directives on electromagnetic compatibility, is placed in a rugged self-extinguishing plastic case suitable for direct assembling on the probe connection head.

TECHNICAL SPECIFICATIONS ( Typical @ 25C and in the nominal conditions )


Input Sensor type Minimum input span Sensor current Input configuration Line resistance influence Output Sensor interrupting signaling Measuring current Current limitation Protection against polarity reversal Response time (10 to 90% of f.s.) Warm up time

PT100 according to IEC 751 50 C or 100F 1 mA 2 o 3 wires 0.05 % of f.s./ for the maximum f.s.* (100

max. balanced on each wire)

Positive out-of-scale 420 mA, two wires Approx. 25 mA 60 V reverse max 0.3 seconds 3 minutes

Performances Calibration error 0.1% of f.s. or 0.1C Linearity error 0.25% of f.s. (inclusive of hysteresis, linearization error and supply voltage variations) Electomagnetic Compatibility (EMC) According to EN50081-2 and EN50082-2 Thermal drift 0.03 % of f.s./C Power supply voltage 10 32 V Operating temperature - 20 70 C Storage temperature - 40 100 C Relative humidity (non condensing) 0 90 % Weight 35 g. *: For lower f.s. this value must be proportionally increased.

Custom execution on request

97

WORKING DIAGRAM

LOAD CHARATERISTIC

OPERATING INSTRUCTIONS The transmitter must be powered with a voltage ranging from 10 to 32 V, applied between the -V and +V terminals. The permissible Rload resistance, equivalent o that of the instruments applied in series to the voltage generator, must be determined as a function of the power supply voltage value and according to the load characteristic so that its value is covered by the working area. The connection of the sensor can be performed with two or three wires. The two-wire connection is performed by connecting the sensor to terminals no. 2 and no. 3 and connecting terminal no.1 to the no. 2. The wiring diagram here below shows a three-wire connection. It is possible and easy to perform the calibration, if needed, just by operating on the zero and span adjustments: after placing at the input a sample resistor of a value corresponding to zero scale, adjust the "zero" potentiometer so as to obtain a 4 mA indication, then, with a resistor of a value corresponding to the full scale, adjust the "span" potentiometer to a 20 mA indication. Repeat these adjustments until the requested accuracy is achieved.

PHYSICAL DIMENSIONS (measures in mm.)


ZERO

CONNECTION DIAGRAM

RTD

3
4

2
2 3 1

1
-V

La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

+V

+V

-V

SPAN

+V RLoad

7 33 43

24 AVAILABLE RANGES
HOW TO ORDER:

DAT 1040 PT100 - 0 100


Scale range (To choose it, refer to the apposite list here at side)

-50 -50 -50 0 0 0 0

50 150 250 100 200 300 500

-50 -50 0 0 0 0 0

100 200 50 150 250 400 600

EDIT.10.00-REV.00

98

Two-wire smart transmitter DAT 1015


FEATURES RTD, TC, mV, Resistor and Potentiometer input Configurable by Personal Computer High accuracy and performance's stability On-field reconfigurable In compliance with EMC standards - CE Mark DIN B head type mounting Available as configured device on user specifications

APPLICATIONS Temperature Monitoring and Control for: - Process Controls - Automation Systems - Energy sources management

GENERAL INFORMATION
Introduction The DAT 1015 is a "smart" in -head transmitter capable to perform many functions such as: Linearized temperature measurement with thermocouple or RTD sensors. Conversion of a linear resistance variation to a standard analog current of 4-20 mA. Conversion of a voltage signal, even coming from a potentiometer connected to its input, to a 4-20 mA linearised signal. Its small mechanical dimension allows the mounting of a "smart" transmitter even in a little space. General The device is built around a microprocessor core which controls any device function in a continuos and reliable mode by an efficient program developped . The unit can be configured to accept input from a wide range of sensors and electrical parameters. Thanks to its versatility of use, it greatly reduces the warehouse stock satisfying a wide variety of needs; thus it offers immediate and evident economical advantages. By means of its continuos self calibrating operation, controlled by the microprocessor, the device guarantees an excellent accuracy and very stable measurement, both in time and in the operating temperature. Further, with this operating mode, the device is not longer subject to the usual variations of the circuit parameters. The units are manufactured by using high quality and high precision electronic components which are assembled by the SMD technology; Both of these elements are the indispensable tools to realize a very reliable device. The DAT 1015, developped, manufactured and tested in strict accordance with the quality assurance standard ISO 9001 / EN 29001, is in compliance with the directive 89/336/CEE on the electromagnetic compatibility and the CE mark confirms the compliance of the product. The device is housed in a rough self estinguish plastic case suitable for mounting on DIN B head. A version of this device for mounting on DIN rails is also available. Input types The DAT 1015 is configurable for any of the following input types: - RTD input for linearised PT100, PT1000, Ni100 and Ni1000. The cable compensation is possible by 3 or 4 wire connection. - Thermocouple input for 8 different types. The Cold Junction Compensation is selectable as internal or external. - Voltage input up to -100/+700 mV. - Resistance input for linear resistance measurement from 20 Ohm to 2 KOhm with 3 or 4 wire compensation. - Potentiometer input from 20 Ohm to 2 KOhm. Output Programmable or standard 4 - 20 mA current output. Programmable Sensor Burnout as "Upscale" or "Downscale". Protection against polarity reversal is provided. Set-Up All the configurable functions and parameters are easily programmed by means of a PC with a software package, named PROSOFT. This "guide lines menu" type program operates under "Windows95" on a PC which communicates, via an interface adapter, with the DAT 1015. The adapter is connected through a cable to an apposite connector situated on the transmitter ( for more detailed information, see the figure in the next page). IMPORTANT: On request the transmitter can be supplied configured for the desired sensor type and calibrated for the specific range as defined in the order ( see "HOW TO ORDER ").

Custom execution on request

99

Configuration options for DAT1015 Transmitter (use this checklist when ordering configurated units):
ORD. CODE
RTD type: O O O O Pt100 Ni100 Pt1000 Ni1000 TC type: O O O O O O O O type J type K type S type R type B type E type T type N

INPUT
Resistance range: 20 Ohm to 2000 Ohm Potentiometer range: O 20 Ohm to 200 Ohm O 200 Ohm to 500 Ohm O 0.5 Kohm to 2 Kohm
ZERO: SPAN:

Voltage input range: -100 mV to 700 mV

Range:

Range:

Range:

Range:

O Standard linearization RTD, TC

Linearization:

O No linearization O Customer linearization (specify):

Linearization:

RTD options: TC options: Res. Options:

O 2-wire O 3-wire O 4-wire

O Intern. CJC O 2-wire O Extern. CJC O 3-wire O 4-wire

OUTPUT
Output current range:

O 4 - 20 mA O 20 - 4 mA O Special (specify):

Sensor Burnout:

O Upscale O Downscale

HOW TO ORDER: A-Not configured device: DAT1015 Code: A B C D E B-Configured device: DAT1015 / Ni1000-0..250C / S.L. / 3-wire / 20..4 / Downscale* (*)The above is an example of how to order a transmitter for Ni1000 sensor, operating in the 0 to 250C range, with standard
linearization, connected to input in the 3-wire connection, with an output of 20 to 4 mA and with downscale sensor burnout.

MECHANICAL DIMENSIONS ( mm. )

LOAD CHARACTERISTIC

3
4

2
1
-V

Custom executiom on request

+V

7 33 43

24 DAT1015
100

DAT 1015 BLOCK AND WIRING DIAGRAM

1 2 3 4 A /D MUX CPU D /A
-V
0 Vcc

P o w er S u pply

+V

_ +

_ +

1 2 3 4

mV

TC

CONFIGURATION
This operation is carried out, using a Personal Computer with "Windows95" operating system, by the software PROSOFT, specifically developped, and by the interfacing adatpter PRODAT-03. The software includes a window-type program by which the operator is guided through the operations to be executed. Once the data are inputed, a few seconds is the time necessary to complete a configuration cycle. The parameters which is possible to configure are illustrated in the "Configuration options" in the page here at side. Furthermore it is possible, in the same phase, to program the "zero" and the "full scale" values. The calibration of the device is made automatically, with the maximum accuracy, without the need of any mechanical regulation. The configuration is normally made at the factory in conformity of the customer' s order or, alternatively, in one of the most used configuration: DAT1015 / Pt100-0..200C / S.L. / 3-wire / 4..20mA / Upscale. The device can be reconfigured for any number of times. This operation is possible also when the device is operating in the plant or in the field because it is possible, by software, to interrupt momentarily the normal operation which restarts automatically after the configuration. In the case that the power supply unit is not avaible, the transmitter can be configured using a 9 V battery. The complete configuration system (which includes: interface module PRODAT-03 and software) is supplied at economical price.

DAT 1015

PRODAT-03

DAT1015

Custom execution on request

101

DAT 1015 Technical Specifications


( typical @ 25C and in the nominal conditions )

Input
RTD Input PT100 PT1000 NI100 NI1000 TC Input J K S R B E T N Voltage Input mV Min -200C -200C -60C -60C Max 850C 200C 180C 150C Span Min 50C 50C 50C 50C

Output
Current Output Signal range Load Resistance (4 - 20 mA) or (20 - 4 mA) (see Load Characteristic)

Accuracy
Linearity TC RTD The larger of The larger of The larger of The larger of

0.2 % (1) 0.1 % (1)

Min -200C -200C -50C -50C 400C -200C -200C -200C

Max 1200C 1370C 1760C 1760C 1820C 1000C 400C 1300C

Span Min 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV

Calibration RTD Res. Low Res. High mV, TC

0.1%(1) and 0,2 C 0.1%(1) and 0,15 Ohm 0.2%(1) and 1 Ohm 0.1%(1) and 18 uV 0.5 C 7 uA

Cold junction comp. Output current Thermal Drift Full Scale 0.01%/C Cold junction Compensation

Min -100mV

Max +700mV

Span Min 2 mV

0.01%/C

Potentiometer Input Min Ohm 20 Ohm 200 KOhm 0.50 Resistance Input Min Low 20 Ohm High 300 Ohm Input impedence TC, mV

Max 200 500 2.00

Span Min 10% 10% 10%

Common data
Supply Supply Voltage Polarity protected 10 - 32 Vdc 60 Vdc

Max 300 Ohm 2000 Ohm

Span Min 10 Ohm 200 Ohm

Temperarture & Humidity Ambient Temperarure Humidity (not condensig)

-20 C to +70 C 0 to 90%

>/=10 MOhm

Lead wire resistance influence TC, mV </=0.8 uV/Ohm RTD 3-wire 0.05%/Ohm (50 Ohm max.)(2) RTD 4-wire 0.005%/Ohm (100 Ohm max.) RTD excitation current Typical 0.350 mA

EMC Emission EN50081-2 Immunity EN50082-2 RF Immunity tested for 10V/m up to 1000MHz Response time Rise time(10 - 90 %) Housing Material Mounting Weight

0,4 sec. approx.

Selfestinguish plastic DIN B head or bigger Approx. 50 g

Note:(1) of input span


(2) Balancing required

EDIT.10.00-REV.00
La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

102

Isolated two-wire smart transmitter DAT 1065


FEATURES RTD, TC, mV, Resistor and Potentiometer input Galvanically isolated Configurable by Personal Computer High accuracy and performance's stability On-field reconfigurable In compliance with EMC standards - CE Mark DIN B head type mounting Available as configured device on user specifications

APPLICATIONS Temperature Monitoring and Control for: - Process Controls - Automation Systems - Energy sources management

GENERAL INFORMATION
Introduction The DAT 1065 is a "smart" in -head transmitter capable to perform many functions such as: Linearized temperature measurement with thermocouple or RTD sensors. Conversion of a linear resistance variation to a standard analog current of 4-20 mA. Conversion of a voltage signal, even coming from a potentiometer connected to its input, to a 4-20 mA linearised signal. Its small mechanical dimension allows the mounting of a "smart" transmitter with galvanic isolation even in a little space. General The device is built around a microprocessor core which controls any device function in a continuos and reliable mode by an efficient program developped. The unit can be configured to accept input from a wide range of sensors and electrical parameters. Thanks to its versatility of use, it greatly reduces the warehouse stock satisfying a wide variety of needs; thus it offers immediate and evident economical advantages. By means of its continuos self calibrating operation, controlled by the microprocessor, the device guarantees an excellent accuracy and very stable measurement, both in time and in the operating temperature. Further, with this operating mode, the device is not longer subject to the usual variations of the circuit parameters. The 2000 Vac galvanic isolation, removing all ground loop effects as the input is electrically and physically isolated from the loop power supply, allows the use of the transmitter even in the heavy environmental conditions found in the industrial applications. The units are manufactured by using high quality and high precision electronic components which are assembled by the SMD technology; Both of these elements are the indispensable tools to realize a very reliable device. The DAT 1065, developped, manufactured and tested in strict accordance with the quality assurance standard ISO 9001 / EN 29001, is in compliance with the directive 89/336/CEE on the electromagnetic compatibility and the CE mark confirms the compliance of the product. The device is housed in a rough self estinguish plastic case suitable for mounting on DIN B head. A version of this device for mounting on DIN rails is also available. Input types The DAT 1065 is configurable for any of the following input types: - RTD input for linearised PT100, PT1000, Ni100 and Ni1000. The cable compensation is possible by 3 or 4 wire connection. - Thermocouple input for 8 different types. The Cold Junction Compensation is selectable as internal or external. - Voltage input up to -100/+700 mV. - Resistance input for linear resistance measurement from 20 Ohm to 2 KOhm with 3 or 4 wire compensation. - Potentiometer input from 20 Ohm to 2 KOhm. Output Programmable or standard 4 - 20 mA current output. Programmable Sensor Burnout as "Upscale" or "Downscale". Protection against polarity reversal is provided. Set-Up All the configurable functions and parameters are easily programmed by means of a PC with a software package, named PROSOFT. This "guide lines menu" type program operates under "Windows95" on a PC which communicates, via an interface adapter, with the DAT 1065. The adapter is connected through a cable to an apposite connector situated on the transmitter ( for more detailed information, see the figure in the next page). IMPORTANT: On request the transmitter can be supplied configured for the desired sensor type and calibrated for the specific range as defined in the order ( see "HOW TO ORDER ").

Custom execution on request

103

Configuration options for DAT1065 Transmitter (use this checklist when ordering configurated units):
ORD. CODE
RTD type: O O O O Pt100 Ni100 Pt1000 Ni1000 TC type: O O O O O O O O type J type K type S type R type B type E type T type N

INPUT
Resistance range: 20 Ohm to 2000 Ohm Potentiometer range: O 20 Ohm to 200 Ohm O 200 Ohm to 500 Ohm O 0.5 Kohm to 2 Kohm
ZERO: SPAN:

Voltage input range: -100 mV to 700 mV

Range:

Range:

Range:

Range:

O Standard linearization RTD, TC

Linearization:

O No linearization O Customer linearization (specify):

Linearization:

RTD options: TC options: Res. Options:

O 2-wire O 3-wire O 4-wire

O Intern. CJC O 2-wire O Extern. CJC O 3-wire O 4-wire

OUTPUT
Output current range:

O 4 - 20 mA O 20 - 4 mA O Special (specify):

Sensor Burnout:

O Upscale O Downscale

HOW TO ORDER: A-Not configured device: DAT1065 Code: A B C D E B-Configured device: DAT1065 / Ni1000-0..250C / S.L. / 3-wire / 20..4 / Downscale* (*)The above is an example of how to order a transmitter for Ni1000 sensor, operating in the 0 to 250C range, with standard
linearization, connected to input in the 3-wire connection, with an output of 20 to 4 mA and with downscale sensor burnout.

MECHANICAL DIMENSIONS ( mm. )

LOAD CHARACTERISTIC

3
4

2
1
-V

Custom executiom on request

+V

7 33 43

24 DAT1065
104

DAT 1065 BLOCK AND WIRING DIAGRAM


1 2 3 4 A/D MUX C PU
-V 0 Vcc

Po wer Su pply

R load
+V 24Vcc &O ut

+ 24 Vcc

_ +

_ +

1 2 3 4

mV

TC

CONFIGURATION
This operation is carried out, using a Personal Computer with "Windows95" operating system, by the software PROSOFT, specifically developped , and by the interfacing adatpter PRODAT-03. The software includes a window-type program by which the operator is guided through the operations to be executed. Once the data are inputed, a few seconds is the time necessary to complete a configuration cycle. The parameters which is possible to configure are illustrated in the "Configuration options" in the page here at side. Furthermore it is possible, in the same phase, to program the "zero" and the "full scale" values. The calibration of the device is made automatically, with the maximum accuracy, without the need of any mechanical regulation. The configuration is normally made at the factory in conformity of the customer' s order or, alternatively, in one of the most used configuration: DAT1065 / Pt100-0..200C / S.L. / 3-wire / 4..20mA / Upscale. The device can be reconfigured for any number of times. This operation is possible also when the device is operating in the plant or in the field because it is possible, by software, to interrupt momentarily the normal operation which restarts automatically after the configuration. In the case that the power supply unit is not avaible, the transmitter can be configured using a 9 V battery. The complete configuration system (which includes: interface module PRODAT-03 and software) is supplied at economical price.

PRODAT-03 DAT 1065

DAT1065

Custom execution on request

105

DAT 1065 Technical Specifications


( typical @ 25C and in the nominal conditions )

Input
RTD Input PT100 PT1000 NI100 NI1000 TC Input J K S R B E T N Voltage Input mV Min -200C -200C -60C -60C Max 850C 200C 180C 150C Span Min 50C 50C 50C 50C

Output
Current Output Signal range Load Resistance (4 - 20 mA) or (20 - 4 mA) (see Load Characteristic)

Accuracy
Linearity TC RTD

0.2 % (1) 0.1 % (1)

Min -200C -200C -50C -50C 400C -200C -200C -200C

Max 1200C 1370C 1760C 1760C 1820C 1000C 400C 1300C

Span Min 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV

Calibration RTD The larger of Res. Low The larger of Res. High The larger of mV, TC The larger of Cold junction comp. Output current Thermal Drift Full Scale 0.01%/C Cold junction Compensation

0.1%(1) and 0,2 C 0.1%(1) and 0,15 Ohm 0.2%(1) and 1 Ohm 0.1%(1) and 18 uV 0.5 C 7 uA

Min -100mV

Max +700mV

Span Min 2 mV

0.01%/C

Potentiometer Input Min Ohm 20 Ohm 200 KOhm 0.50 Resistance Input Min Low 20 Ohm High 300 Ohm Input impedence TC, mV

Common data
Max 200 500 2.00 Span Min 10% 10% 10% Supply Supply Voltage Isolation Voltage Polarity protected 10 - 32 Vdc 2000 Vac for 60 Sec 60 Vdc

Max 300 Ohm 2000 Ohm

Span Min 10 Ohm 200 Ohm

Temperarture & Humidity Ambient Temperarure Humidity (not condensig)

-20 C to +70 C 0 to 90%

>/=10 MOhm

Lead wire resistance influence TC, mV </=0.8 uV/Ohm RTD 3-wire 0.05%/Ohm (50 Ohm max.)(2) RTD 4-wire 0.005%/Ohm (100 Ohm max.) RTD excitation current Typical 0.350 mA

EMC Emission EN50081-2 Immunity EN50082-2 RF Immunity tested for 10V/m up to 1000MHz Response time Rise time(10 - 90 %) Housing Material Mounting Weight

0,4 sec. approx.

Selfestinguish plastic DIN B head or bigger Approx. 50 g

Note:(1) of input span


(2) Balancing required

EDIT.01.01-REV.01
La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

106

3 way galvanically isolated configurable conditioner for Pt100 DAT 2060


FEATURES Pt100 input isolated from output and power supply Input range and output signal configurable Linearized output, voltage or current Configurable by means of DIP switches 2000Vac galvanic isolation on the 3 ways Independent zero and full scale regulations Good accuracy and performance stability EMC compliant - CE mark 12,5mm only enclosure thickness DIN rail mounting

APPLICATIONS Control and monitoring of the temperature for: - Process controls - Automation systems - Energy sources management

GENERAL INFORMATION
The DAT 2060 signal conditioner accepts at its input Pt100 sensor connected in two or three wire configuration. It provides to convert the Pt100 signal into a correspondent output analog normalized signal. Moreover it operates at 2000Vac full isolation among input, output and power supply. This allows to eliminate the problems coming from the reciprocal influence of the various circuits, and coming from the induced noise through the ground loops. The input signal range and the type and the value of the output signal are configurable in a wide range of combinations (see table "Configurability"). They are selected by means of suitable DIP switches. The DAT 2060 unit, developped, manufactured and tested in strict accordance with the quality assurance standard ISO 9001 / EN 29001, is in compliance with the directive 89/336/CEE on the electromagnetic compatibility. It is packaged into a strong plastic enclosure of only 12,5mm thickness, allowing an high density mounting capability on DIN rail.

TECHNICAL SPECIFICATIONS ( Typical @25C and in the normal conditions)


INPUT Sensor type Zero Span Sensor current Influence of line resistance OUTPUT Output signal Max output signal Load resistance Reverse polarity protection Response time (from 10 % to 90% e.s.) Warm up time Pt100 according to IEC 751, other Rtd type available on request. Programmable in the -50C to +50C range Programmable from 50C to 650C 1 mA 0.05% of f.s./Ohm for f.s. max.(100 Ohm max. balanced on each wire).

configurable: V, +/- V, mA (see table "Configurability") 15Vdc or 30mAdc >/=5 KOhm or </=500 Ohm 60 V reverse max. 0.5 s. 3 min.

CHARACTERISTIC PERFORMANCES Calibration error 0.1% of f. s. or 0,1C Transmission error 0.15% of f.s. (inclusive of hysteresys, linearization error and power supply voltage variations) Electro Magnetic Compatibility (EMC) In compliance with EN50081-2 and EN50082-2 Thermal drift 0.02% of f.s./C Power Supply Voltage 18 32 Vdc Current consumption </= 70 mA Isolation among the 3 ways 2000 Vac, 50 Hz, 1 min. Operating temperature - 20 70 C Storage temperature - 40 100 C Relative humidity (non condensing) 0 90 % Weight approx. 90 g.

Custom execution on request

107

OPERATING INSTRUCTIONS
The converter must be powered with a Power Supply Voltage comprised in the 18V to 32V range which must be connected to the terminals R(+24Vdc) and Q(GND3). The green LED switched on indicates the situation of a correct power supply. The Pt100 sensor must be connected between terminal G and terminal L while the third wire has to be connected to terminal I. The output signal, voltage or current, is available between the terminals N(OUT V/I) and M(GND2). The input and output configuration is possible by means of the two DIP switches DSI and DSO. They are accessible only after the opening of the apposite door on the housing side. The table "Configurability" shows the lists of the possible input ranges and output signals and the positioning of the switches to obtain their combinations. After the programming of the conditioner, it is necessary to proceed to its calibration by means of the two regulations of ZERO and SPAN available on the top of the enclosure. The DAT 2060 unit is supplied with the requested configuration at the moment of the order. In case of order without this specification, the unit is supplied with a standard setting: IN=0200C and OUT= 0-10V. In the case it is necessary a calibration of the device , it can be done in a very simple manner thanks to the complete independence of the zero and span regulations.

DIMENSIONS ( mm.)
I L

BLOCK DIAGRAM
N.C. N.C. N.C.

F E H G L I

R +24Vdc Q GND3 O
N.C. N.C.

G H

Pt1
98
E F

Pt100

Pt2 Pt3

P N OUT V/I M GND2

TERMINAL ASSIGNEMENT
12.5 90

E N.C. F N.C:

M GND2 N O P Q R OUT V/I N.C. N.C. GND3 +24Vdc

HOW TO ORDER:

G Pt1 H I L N.C. Pt3 Pt2

DAT 2060 0-200 C - 4/20mA


Input Output

EDIT.10.00-REV.00
La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

108

Programmable transmitter for thermoresistance Pt100 DAT 2065


FEATURES Pt100 input Input range programmable Linearized 4 - 20 mA output Configurable by means of DIP switches Independent zero and full scale regulations Good accuracy and performance stability EMC compliant - CE mark 12,5mm only enclosure thickness DIN rail mounting

APPLICATIONS Control and monitoring of the temperature for: - Process controls - Automation systems - Energy sources management

GENERAL INFORMATION
The DAT 2065 transmitter accepts at its input Pt100 sensor connected in two or three wire configuration. It provides to convert the Pt100 signal into a correspondent 4 - 20 mA output signal. The input signal range is programmable in a wide range of values (see table "Programmability"). They are selected by means of suitable DIP switches which are accessible after opening the door on the housing side. The fine adjustment of the programmed value is made by means of the proper trimmers for zero and span regulation. These adjustments are one independent from the other. The DAT 2065 unit, developped, manufactured and tested in strict accordance with the quality assurance standard ISO 9001 / EN 29001, is in compliance with the directive 89/336/CEE on the electromagnetic compatibility. It is packaged into a strong plastic enclosure of only 12,5mm thickness, allowing an high density mounting capability on DIN rail.

TECHNICAL SPECIFICATIONS ( Typical @25C and in the normal conditions)


INPUT Sensor type Zero Span Sensor current Influence of line resistance OUTPUT Output signal Max output signal Load resistance Reverse polarity protection Response time (from 10 % to 90% e.s.) Warm up time Pt100 according to IEC 75 ( other Rtd type available on request ) Programmable in the -50C to +50C range Programmable from 50C to 650C 0.6 mA typ. 0.05% of f.s./Ohm for f.s. max.(100 Ohm max. balanced on each wire).

4 - 20 mA 30mAdc see the "Load characteristic" 60 V reverse max. 0.5 s. 3 min.

CHARACTERISTIC PERFORMANCES Calibration error 0.1% of f. s. or 0,1C Transmission error 0.15% of f.s. (inclusive of hysteresys, linearization error and power supply voltage variations) Electro Magnetic Compatibility (EMC) In compliance with EN50081-2 and EN50082-2 Thermal drift 0.02% of f.s./C Power Supply Voltage 18 30 Vdc Current consumption 33 mA Max. on open input condition Operating temperature - 20 70 C Storage temperature - 40 100 C Relative humidity (non condensing) 0 90 % Weight approx. 80 g.

Custom execution on request

109

WORKING AREA

Power Supply Voltage

OPERATING INSTRUCTIONS
The DAT 2065 Transmitter must be powered with a suitable voltage between 10 and 30Vdc, which must be supplied to the terminal Q or R (+24Vdc & Vout), and the terminal O or P (GND). A too high value of the load (RLoad), which is constituted by the instrumentation serie connected to the loop, determines a non-correct running of the Transmitter. Therefore it is necessary that the value of RLoad, which is determined in function of the power supply, must be contained in the Working Area which is indicated in the Load Characteristics above shown. The Pt100 sensor must be connected between the terminals I or L and the terminals H or G, while the 3rd wire must be connected to the terminals E or F. The output signal , is available between the terminals Q or R (Out & +24Vdc), and the terminals O or P (GND). The DIPswitches DSI carry the programming of the input. They are accessible only after the opening the suitable access on the side of the enclosure. The Programming guide shows the list of the possible input measuring range, and the indication of the positioning of the DIP switches to obtain the selected configuration. Once such operation is finished, it is necessary to proceed to the calibration of the Transmitter by means of the two settings ZERO and SPAN on the top of the enclosure. The DAT 2065 is supplied with the calibration requested by the Customer in his order. In case such calibration is not indicated, the device is supplied with the following standard configuration: IN=0-200C: When it is necessary to calibrate the Transmitter, this can be done in a very simple and fast way, thanks to the complete independence of the zero and span settings.

DIMENSIONS ( mm.)
I L

BLOCK DIAGRAM

LINEARIZER
G H

M-N

N.C.

Pt1
98
E F

Pt100

Pt2 Pt3

I-L H-G R E-F V

Out &

Q-R +24Vdc
CURRENT TRANSMITTER

O-P GND

TERMINAL ASSIGNEMENT
E
12.5 90

Pt3 Pt3 Pt2 Pt2 Pt1 Pt1

M N O P Q R

N.C. N.C. GND GND Out & +24Vdc Out & +24Vdc

F G

HOW TO ORDER:

H I L

DAT 2065 0-200 C - 4/20mA


Input

EDIT.10.00-REV.00
La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

110

Two-wire smart transmitter DAT 2015


FEATURES RTD, TC, mV, V, mA, Resistor and Potentiometer input Configurable by Personal Computer High accuracy and performance's stability On-field reconfigurable In compliance with EMC standards - CE Mark DIN rail mounting Available as configured device on user specifications

APPLICATIONS Temperature Monitoring and Control for: - Process Controls - Automation Systems - Energy sources management

GENERAL INFORMATION
Introduction The DAT 2015 is a "smart" transmitter capable to perform many functions such as: Linearized temperature measurement with thermocouple or RTD sensors. Conversion of a linear resistance variation to a standard analog current of 4-20 mA. Conversion of a voltage signal, even coming from a potentiometer connected to its input, to a 4-20 mA linearized signal. Its very thin profile allows to mount a "smart" transmitter even at a pitch of only 12.5 mm on the DIN rail. General The device is built around a microprocessor core which controls any device function in a continuos and reliable mode by an efficient program developped. The unit can be configured to accept input from a wide range of sensors and electrical parameters. Thanks to its versatility of use, it greatly reduces the warehouse stock satisfying a wide variety of needs; thus it offers immediate and evident economical advantages. By means of its continuos self calibrating operation, controlled by the microprocessor, the device guarantees an excellent accuracy and very stable measurement, both in time and in the operating temperature. Further, with this operating mode, the device is not longer subject to the usual variations of the circuit parameters. The units are manufactured by using high quality and high precision electronic components which are assembled by the SMD technology; Both of these elements are the indispensable tools to realize a very reliable device. The DAT 2015, developped, manufactured and tested in strict accordance with the quality assurance standard ISO 9001 / EN 29001, is in compliance with the directive 89/336/CEE on the electromagnetic compatibility and the CE mark confirms the compliance of the product. The device is housed in a rough self estinguish plastic container suitable for mounting on DIN rails. A version of this device for mounting on DIN B head is also available. Input types The DAT 2015 is configurable for any of the following input types: - RTD input for linearised PT100, PT1000, Ni100 and Ni1000. The cable compensation is possible by 3 or 4 wire connection. - Thermocouple input for 8 different types. The Cold Junction Compensation is selectable as internal or external. - Current input from -10 to +24 mA. - Voltage input up to -400/+700 mV or up to +/-10 V - Resistance input for linear resistance measurement from 20 Ohm to 2 KOhm with 3 or 4 wire compensation. - Potentiometer input from 20 Ohm to 50 KOhm. Output Programmable or standard 4 - 20 mA current output. Programmable Sensor Burnout as "Upscale" or "Downscale". Protection against polarity reversal is provided. Set-Up All the configurable functions and parameters are easily programmed by means of a PC with a software package, named PROSOFTT . This "guide lines menu" type program operates under "Windows95TM" on a PC which communicates, via an interface adapter, with the DAT 2015. The adapter is connected through a cable to an apposite connector situated on the transmitter ( for more detailed information, see the figure in the next page). IMPORTANT: On request the transmitter can be supplied configured for the desired sensor type and calibrated for the specific range as defined in the order ( see "HOW TO ORDER ").
Custom execution on request

111

Configuration options for DAT2015 Transmitter (use this checklist when ordering configurated units):
ORD. CODE
RTD type: O O O O Pt100 Ni100 Pt1000 Ni1000 TC type: O O O O O O O O type J type K type S type R type B type E type T type N

INPUT
Resistance range: 20 Ohm to 2000 Ohm Potentiometer range: O 20 Ohm to 200 Ohm O 200 Ohm to 500 Ohm O 0.5 Kohm to 50 Kohm
ZERO: SPAN:

Range:

Range:

Range:

Voltage input range: O +/- 400 mV with input applied on L terminal O +/- 10 V with input applied on E terminal
Range:

Current input range: -10 to 24 mA

Range:

O Standard linearization RTD, TC

Linearization:

O No linearization O Customer linearization (specify):

Linearization:

RTD options: TC options: Res. Options:

O 2-wire O 3-wire O 4-wire

O Intern. CJC O 2-wire O Extern. CJC O 3-wire O 4-wire

OUTPUT
Output current range:

O 4 - 20 mA O 20 - 4 mA O Special

Sensor Burnout:

O Upscale O Downscale

HOW TO ORDER: A-Not configured device: DAT2015 Code: A B C D E B-Configured device: DAT2015 / TC K-0..1200C / S.L. / Int. C.J.C. / 4..20mA / Upscale* (*)The above is an example of how to order a transmitter for TC type K sensor, operating in the 0 to 1200C range, with standard
linearization, with internal C.J.C., with an output of 4 to 20 mA and with upscale sensor burnout.

MECHANICAL DIMENSIONS (mm.)

LOAD CHARACTERISTIC

G H

98

12.5

90

DAT 2015
Custom executiom on request

112

DAT 2015 BLOCK AND WIRING DIAGRAM


I L G H E F A /D MUX CPU D /A P o w er S u pply P N M O
0 Vc c

CONFIGURATION
This operation is carried out, using a Personal Computer with "Windows95" operating system, by the software PROSOFT, specifically developped , and by the interfacing adatpter PRODAT-03. The software includes a window-type program by which the operator is guided through the operations to be executed. Once the data are inputed, a few seconds is the time necessary to complete a configuration cycle. The parameters which is possible to configure are illustrated in the "Configuration options" in the page here at side. Furthermore it is possible, in the same phase, to program the "zero" and the "full scale" values. The calibrationof the device is made automatically, with the maximum accuracy, without the need of any mechanical regulation. The configuration is normally made at the factory in conformity to the customer' s order or, alternatively, in one of the most used configuration: DAT2015 / Pt100-0..200C / S.L. / 3-wire / 4..20mA / Upscale. The device can be reconfigured for any number of times. This operation is possible also when the device is operating in the plant or in the field because it is possible, by software, to interrupt momentarily the normal operation which restarts automatically after the configuration. In the case that the power supply unit is not avaible, the transmitter can be configured using a 9 V battery. The complete configuration system (which includes: interface module PRODAT-03 and software) is supplied at economical price.

DAT 2015
Custom execution on request

PRODAT-03 113

DAT 2015

DAT 2015 Technical Specifications


( typical @ 25C and in the nominal conditions )

Input
RTD Input PT100 PT1000 NI100 NI1000 TC Input J K S R B E T N Voltage Input mV mV V Min -200C -200C -60C -60C Max 850C 200C 180C 150C Span Min 50C 50C 50C 50C

Output
Current Output Signal range Load Resistance (4 - 20 mA) or (20 - 4 mA) (see Load Characteristic)

Accuracy
Linearity TC RTD

Min -200C -200C -50C -50C 400C -200C -200C -200C

Max 1200C 1370C 1760C 1760C 1820C 1000C 400C 1300C

Span Min 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV

0.2 % (1) 0.1 % (1)

Calibration RTD The larger of Res. Low The larger of Res. High The larger of mV, TC The larger of V The larger of Input current The larger of Cold junction comp. Output current Thermal Drift Full Scale 0.01%/C Cold junction Compensation

0.1%(1) and 0.2 C 0.1%(1) and 0.15 Ohm 0.2%(1) and 1 Ohm 0.1%(1) and 18 uV 0.1%(1) and 2 mV 0.1%(1) and 6 uV 0.5 C 7 uA

Min -100 -400 -10V

Max +700 +400 +10V

Span Min 2 mV 2 mV 500 mV

0.01%/C

Potentiometer Range Min Ohm 20 Ohm 200 KOhm 0.50 Resistance Input Min Low 20 Ohm High 300 Ohm Current Input mA

Max 200 500 50

Span Min 10% 10% 10%

Common data
Supply Supply Voltage Polarity protected 10 - 32 Vdc 60 Vdc

Max 300 Ohm 2000 Ohm

Span Min 10 Ohm 200 Ohm

Temperarture & Humidity Ambient Temperarure Humidity (not condensig)

-20 C to +70 C 0 to 90%

Min -10mA

Max +24 mA

Span Min 2 mA

EMC Emission EN50081-2 Immunity EN50082-2 RF Immunity tested for 10V/m up to 1000MHz Response time Rise time(10 - 90 %) Housing Material Mounting Weight

Input impedence TC, mV V Current

>/=10 MOhm >/= 1 MOhm 50 Ohm

0.4 sec. approx.

Lead wire resistance influence TC, mV ,V >/=0.8uV/Ohm RTD 3-wire 0.05%/Ohm (50 Ohm max) (2) RTD 4-wire 0.005%/Ohm (100 Ohm max) RTD Sensor Current Typical

Selfestinguish plastic DIN B head or bigger Approx. 50 g

Note:(1) of input span


(2) Balancing required

0.350 mA EDIT.10.00-REV.00

La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

114

Smart signal conditioner DAT 2115


FEATURES RTD, TC, mV, V, mA, Resistor and Potentiometer input Voltage and current output Configurable by Personal Computer High accuracy and performance's stability On-field reconfigurable In compliance with EMC standards - CE Mark DIN rail mounting Available as configured device on user specifications APPLICATIONS Temperature Monitoring and Control for: - Process Controls - Automation Systems - Energy sources management

GENERAL INFORMATION
Introduction The DAT 2115 is a "smart" conditioner capable to perform many functions such as: Linearized temperature measurement with thermocouple or RTD sensors. Conversion of a linear resistance variation to a standard analog current or voltage signal. Conversion of a voltage signal, even coming from a potentiometer connected to its input, to a current or voltage linearized signal. Its very thin profile allows to mount a "smart" conditioner even at a pitch of only 12.5 mm on the DIN rail. General The device is built around a microprocessor core which controls any device function in a continuos and reliable mode by an efficient program developped . The unit can be configured to accept input from a wide range of sensors and electrical parameters and to supply in the output a current or voltage signal. Thanks to its versatility of use, it greatly reduces the warehouse stock satisfying a wide variety of needs; thus it offers immediate and evident economical advantages. By means of its continuos self calibrating operation, controlled by the microprocessor, the device guarantees an excellent accuracy and very stable measurement, both in time and in the operating temperature. Further, with this operating mode, the device is not longer subject to the usual variations of the circuit parameters. The units are manufactured by using high quality and high precision electronic components which are assembled by the SMD technology; Both of these elements are the indispensable tools to realize a very reliable device. The DAT 2115, developped, manufactured and tested in strict accordance with the quality assurance standard ISO 9001 / EN 29001, is in compliance with the directive 89/336/CEE on the electromagnetic compatibility and the CE mark confirms the compliance of the product. The device is housed in a rough self estinguish plastic container suitable for mounting on DIN rails. Input types The DAT2115 is configurable for any of the following input types: - RTD input for linearised PT100, PT1000, Ni100 and Ni1000. The cable compensation is possible by 3 or 4 wire connection. - Thermocouple input for 8 different types. The Cold Junction Compensation is selectable as internal or external. - Current input from -10 to +24 mA. - Voltage input up to -400/+700 mV or up to +/-10 V - Resistance input for linear resistance measurement from 20 Ohm to 2 KOhm with 3 or 4 wire compensation. - Potentiometer input from 20 Ohm to 50 KOhm. Output Programmable current or voltage ouput in the 0 to 20 mA or 0 to 10 v range. Programmable Sensor Burnout as "Upscale" or "Downscale". Short circuit protection is provided on the output. Set-Up All the configurable functions and parameters are easily programmed by means of a PC with a software package, named PROSOFT. This "guide lines menu" type program operates under "Windows95TM" on a PC which communicate, via an interface adapter, with the DAT2115. The adapter is connected through a cable to an apposite connector situated on the conditioner ( for more detailed information, see the figure in the next page). IMPORTANT: On request the transmitter can be supplied configured for the desired sensor type and calibrated for the specific range as defined in the order ( see "HOW TO ORDER ").

Custom execution on request

115

Configuration options for DAT2115 Conditioner (use this checklist when ordering configurated units):
ORD. CODE
RTD type: O O O O Pt100 Ni100 Pt1000 Ni1000 TC type: O O O O O O O O type J type K type S type R type B type E type T type N

INPUT
Resistance range: 20 Ohm to 2000 Ohm Potentiometer range: O 20 Ohm to 200 Ohm O 200 Ohm to 500 Ohm O 0.5 Kohm to 50 Kohm
ZERO: SPAN:

Range:

Range:

Range:

Voltage input range: O +/- 400 mV with input applied on L terminal O +/- 10 V with input applied on E terminal
Range:

Current input range: -10 to 24 mA

Range:

O Standard linearization RTD, TC

Linearization:

O No linearization O Customer linearization (specify):

Linearization:

RTD options: TC options: Res. Options:

O 2-wire O 3-wire O 4-wire

O Intern. CJC O 2-wire O Extern. CJC O 3-wire O 4-wire

OUTPUT
Output range:

O 0 - 20 mA O 20 - 0 mA O Special

O 4 - 20 mA O 20 - 4 mA

O 0-5V O 5-0V

O O

0 - 10 V 10 - 0 V

Sensor Burnout:

O Upscale O Downscale

HOW TO ORDER: A-Not configured device: DAT2115 Code: A B C D E B-Configured device: DAT2115 / TC J-50..600C / S.L. / Int. C.J.C. / 0..10V / Upscale* (*)The above is an example of how to order a conditioner for TC type J sensor, operating in the 0 to 600C range, with standard
linearization, with internal C.J.C., with an output of 0 to 10 V and with upscale sensor burnout.

MECHANICAL DIMENSIONS (mm.)


I L

98

12.5

90

DAT2115
Custom executiom on request

116

DAT 2115 BLOCK AND WIRING DIAGRAM


I L G H E F A /D MUX CPU D /A P ow e r S up ply R N M Q

CONFIGURATION
This operation is carried out, using a Personal Computer with "Windows95" operating system, by the software PROSOFT, specifically developped, and by the interfacing adatpter PRODAT-03. The software includes a window-type program by which the operator is guided through the operations to be executed. Once the data are inputed, a few seconds is the time necessary to complete a configuration cycle, while the time necessary for the introduction of data is some ten of seconds. The parameters which is possible to configure are illustrated in the "Configuration Scheme" in the page here at side. Furthermore it is possible, in the same phase, to program the "zero" and the "full scale" values. The calibrationof the device is made automatically, with the maximum accuracy, without the need of any mechanical regulation. The configuration is normally made at the factory in conformity to the customer' s order or, alternatively, in one of the most used configuration: DAT2115 / Pt100-0..200C / S.L. / 3-wire / 4..20mA / Upscale. The device can be reconfigured and reprogrammed for any number of time. This operation is possible also when the device is operating in the plant or in the field because it is possible, by software, to interrupt momentarily the normal operation which restarts automatically after the configuration. In the case that the power supply unit is not avaible, the conditioner can be configured using a 9 V battery. The complete configuration system (which includes: interface module PRODAT-03 and software) is supplied at economical price.

DAT2115
Custom execution on request

PRODAT-03 117

DAT2115

DAT2115 Technical Specifications


( typical @ 25C and in the nominal conditions )

Output
Current Output Signal range Load Resistance Voltage Output Signal range Load Resistance Short circuit current (0/4 - 20 mA) or (20 - 4/0 mA) 650 Ohm max. (0 - 5/10 V) or (10/5 - 0 V) 3.5 K Ohm min. 20 mA approx. TC RTD

Input
RTD Input PT100 PT1000 NI100 NI1000 TC Input J K S R B E T N Voltage Input mV mV V Min -200C -200C -60C -60C Max 850C 200C 180C 150C Span Min 50C 50C 50C 50C

Accuracy
Linearity

Min -200C -200C -50C -50C 400C -200C -200C -200C

Max 1200C 1370C 1760C 1760C 1820C 1000C 400C 1300C

Span Min 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV

0.2 % (1) 0.1 % (1)

Min -100 -400 -10V

Max +700 +400 +10V

Span Min 2 mV 2 mV 500 mV

Calibration RTD The larger of Res. Low The larger of Res. High The larger of mV, TC The larger of V The larger of Input current The larger of Cold junction comp. Output current Output voltage Thermal Drift Full Scale 0.01%/C Cold junction Compensation

0.1%(1) and 0.2 C 0.1%(1) and 0.15 Ohm 0.2%(1) and 1 Ohm 0.1%(1) and 18 uV 0.1%(1) and 2 mV 0.1%(1) and 6 uV 0.5 C 7 uA 5 mV

Potentiometer Range Min Ohm 20 Ohm 200 KOhm 0.50 Resistance Input Min Low 20 Ohm High 300 Ohm Current Input mA

0.01%/C

Max 200 500 50

Span Min 10% 10% 10%

Common data
Supply Supply Voltage 18 - 30 Vdc Supply current 40 mA at 24 Vdc Polarity protected 60 Vdc Temperarture & Humidity Ambient Temperarure -20 C to +70 C Humidity (not condensig) 0 to 90% EMC Emission EN50081-2 Immunity EN50082-2 RF Immunity tested for 10V/m up to 1000MHz Response time Rise time(10 - 90 %) 0,4 sec. approx. Housing Material Mounting Weight

Max 300 Ohm 2000 Ohm

Span Min 10 Ohm 200 Ohm

Min -10mA

Max +24 mA

Span Min 2 mA

Input impedence TC, mV V Current

>/=10 MOhm >/= 1 MOhm 50 Ohm

Lead wire resistance influence TC, mV ,V </=0.8uV/Ohm RTD 3-wire 0.05%/Ohm (50 Ohm max) (2) RTD 4-wire 0.005%/Ohm (100 Ohm max) RTD Sensor Current Typical

Selfestinguish plastic DIN B head or bigger Approx. 50 g

Note:(1) of input span


(2) Balancing required

0.350 mA EDIZ.10.00-REV.00

La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

118

Configurable conditioner for thermoresistance Pt100 DAT 2165


FEATURES Pt100 input Input range and output signal configurable Linearized output, voltage or current Configurable by means of DIP switches Independent zero and full scale regulations Good accuracy and performance stability EMC compliant - CE mark 12,5mm only enclosure thickness DIN rail mounting

APPLICATIONS Control and monitoring of the temperature for: - Process controls - Automation systems - Energy sources management

GENERAL INFORMATION
The DAT 2165 signal conditioner accepts at its input Pt100 sensor connected in two or three wire configuration. It provides to convert the Pt100 signal into a correspondent output analog normalized signal. The input signal range and the type and the value of the output signal are configurable in a wide range of combinations (see table "Configurability"). They are selected by means of suitable DIP switches which are accessible after opening the apposite door on the housing side. The fine adjustments of the programmed value is realized by means of the proper trimmers for zero and span regulations. These adjustments are one independent from the other. The DAT 2165 unit, developped, manufactured and tested in strict accordance with the quality assurance standard ISO 9001 / EN 29001, is in compliance with the directive 89/336/CEE on the electromagnetic compatibility. It is packaged into a strong plastic enclosure of only 12,5mm thickness, allowing an high density mounting capability on DIN rail.

TECHNICAL SPECIFICATIONS ( Typical @25C and in the normal conditions)


INPUT Sensor type Zero Span Sensor current Influence of line resistance OUTPUT Output signal Max output signal Load resistance Reverse polarity protection Response time (from 10 % to 90% e.s.) Warm up time Pt100 according to IEC 751( other Rtd type available on request ) Programmable in the -50C to +50C range Programmable from 50C to 650C 1 mA 0.05% of f.s./Ohm for f.s. max.(100 Ohm max. balanced on each wire).

configurable: V and mA (see table "Configurability") 18Vdc or 35mAdc >/=2 KOhm or </=500 Ohm 60 Vdc reverse max. 0.5 s. 3 min.

CHARACTERISTIC PERFORMANCES Calibration error 0.1% of f. s. or 0,1C Transmission error 0.15% of f.s. (inclusive of hysteresys, linearization error and power supply voltage variations) Electro Magnetic Compatibility (EMC) In compliance with EN50081-2 and EN50082-2 Thermal drift 0.02% of f.s./C Power Supply Voltage 18 30 Vdc Current consumption </= 40 mA Operating temperature - 20 70 C Storage temperature - 40 100 C Relative humidity (non condensing) 0 90 % Weight approx. 80 g.

Custom execution on request

119

OPERATING INSTRUCTIONS
The converter must be powered with a power supply voltage between 18V and 30V which must be connected to the terminals Q or R(+24Vdc) and O or P (GND). The Pt100 sensor must be connected between terminal I or L and terminal H or G while the third wire has to be connected to terminal E or F. The output signal, voltage or current, is available between the terminals M or N(OUT V/I) and O or P(GND). The input and output configuration is possible by means of the two DIP switches DSI and DSO. They are accessible only after the opening of the apposite door on the housing side. The table "Configurability" shows the lists of the possible input ranges and output signals and the positioning of the switches to obtain their combinations. After the programming of the conditioner, it is necessary to proceed to its calibration by means of the two regulations of ZERO and SPAN available on the top of the enclosure. The DAT 2165 unit is supplied with the requested configuration at the moment of the order. In case of order without this specification, the unit is supplied with a standard setting: IN=0200C and OUT= 0-10V. In case it is necessary a calibration of the device , it can be done in a very simple and fast way thanks to the complete independence of the zero and span regulations.

DIMENSIONS ( mm.)
I L

BLOCK DIAGRAM

LINEARIZER
G H

Q-R +24Vdc

98

Pt1
Pt100

Pt2 Pt3

I-L H-G R E-F V

M-N OUT V/I


OUTPUT AMPL. /CONDITIONER

O-P GND

TERMINAL ASSIGNEMENT
E
12.5 90

Pt3 Pt3 Pt2 Pt2 Pt1 Pt1

M N O P Q R

OUT OUT GND GND +24Vdc +24Vdc

F G H I L

HOW TO ORDER:

DAT 2165 0-200 C - 4/20mA


Input Output

EDIT.10.00-REV.00
La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

120

Isolated two-wire smart transmitter DAT 4035


FEATURES RTD, TC, mV, V, mA, Resistor and Potentiometer input Galvanically isolated Configurable by Personal Computer High accuracy and performance's stability On-field reconfigurable In compliance with EMC standards - CE Mark DIN rail mounting Available as configured device on user specifications

APPLICATIONS Temperature Monitoring and Control for: - Process Controls - Automation Systems - Energy sources management

GENERAL INFORMATION
Introduction The DAT 4035 is a "smart" transmitter capable to perform many functions such as: Linearized temperature measurement with thermocouple or RTD sensors. Conversion of a linear resistance variation to a standard analog current of 4-20 mA. Conversion of a voltage signal, even coming from a potentiometer connected to its input, to a 4-20 mA linearized signal. Its very thin profile allows to mount a "smart" transmitter with galvanic isolation even at a pitch of only 12.5 mm on the DIN rail. General The device is built around a microprocessor core which controls any device function in a continuos and reliable mode by an efficient program developped. The unit can be configured to accept input from a wide range of sensors and electrical parameters. Thanks to its versatility of use, it greatly reduces the warehouse stock satisfying a wide variety of needs; thus it offers immediate and evident economical advantages. By means of its continuos self calibrating operation, controlled by the microprocessor, the device guarantees an excellent accuracy and very stable measurement, both in time and in the operating temperature. Further, with this operating mode, the device is not longer subject to the usual variations of the circuit parameters. The 2000 Vac galvanic isolation, removing all ground loop effects as the input is electrically and physically isolated from the loop power supply, allows the use of the transmitter even in the heavy environmental conditions found in the industrial applications. The units are manufactured by using high quality and high precision electronic components which are assembled by the SMD technology; Both of these elements are the indispensable tools to realize a very reliable device. The DAT 4035, developped, manufactured and tested in strict accordance with the quality assurance standard ISO 9001 / EN 29001, is in compliance with the directive 89/336/CEE on the electromagnetic compatibility and the CE mark confirms the compliance of the product. The device is housed in a rough self estinguish plastic container suitable for mounting on DIN rails. A version of this device for mounting on DIN B head is also available. Input types The DAT 4035 is configurable for any of the following input types: - RTD input for linearised PT100, PT1000, Ni100 and Ni1000. The cable compensation is possible by 3 or 4 wire connection. - Thermocouple input for 8 different types. The Cold Junction Compensation is selectable as internal or external. - Current input from -10 to +24 mA. - Voltage input up to -400/+700 mV or up to +/-10 V - Resistance input for linear resistance measurement from 20 Ohm to 2 KOhm with 3 or 4 wire compensation. - Potentiometer input from 20 Ohm to 50 KOhm. Output Programmable or standard 4 - 20 mA current output. Programmable Sensor Burnout as "Upscale" or "Downscale". Protection against polarity reversal is provided. Set-Up All the configurable functions and parameters are easily programmed by means of a PC with a software package, named PROSOFT, developed. This "guide lines menu" type program operates under "Windows95TM" on a PC which communicates, via an interface adapter, with the DAT 4035. The adapter is connected through a cable to an apposite connector situated on the transmitter ( for more detailed information, see the figure in the next page). IMPORTANT: On request the transmitter can be supplied configured for the desired sensor type and calibrated for the specific range as defined in the order ( see "HOW TO ORDER ").

Custom execution on request

121

Configuration options for DAT4035 Transmitter (use this checklist when ordering configurated units):
ORD. CODE
RTD type: O O O O Pt100 Ni100 Pt1000 Ni1000 TC type: O O O O O O O O type J type K type S type R type B type E type T type N

INPUT
Resistance range: 20 Ohm to 2000 Ohm Potentiometer range: O 20 Ohm to 200 Ohm O 200 Ohm to 500 Ohm O 0.5 Kohm to 50 Kohm
ZERO: SPAN:

Range:

Range:

Range:

Voltage input range: O +/- 400 mV with input applied on L terminal O +/- 10 V with input applied on E terminal
Range:

Current input range: -10 to 24 mA

Range:

O Standard linearization RTD, TC

Linearization:

O No linearization O Customer linearization (specify):

Linearization:

RTD options: TC options: Res. Options:

O 2-wire O 3-wire O 4-wire

O Intern. CJC O 2-wire O Extern. CJC O 3-wire O 4-wire

OUTPUT
Output current range:

O 4 - 20 mA O 20 - 4 mA O Special

Sensor Burnout:

O Upscale O Downscale

HOW TO ORDER: A-Not configured device: DAT4035 Code: A B C D E B-Configured device: DAT4035 / TC K-0..1200C / S.L. / Int. C.J.C. / 4..20mA / Upscale* (*)The above is an example of how to order a transmitter for TC type K sensor, operating in the 0 to 1200C range, with standard
linearization, with internal C.J.C., with an output of 4 to 20 mA and with upscale sensor burnout.

MECHANICAL DIMENSIONS (mm.)

LOAD CHARACTERISTIC

98

12.5

90

DAT 4035
Custom executiom on request

122

DAT 4035 BLOCK AND WIRING DIAGRAM


I L G H E F A /D MUX CPU M O
0 Vcc

P o w er S u pply

P N

CONFIGURATION
This operation is carried out, using a Personal Computer with "Windows95" operating system, by the software PROSOFT, specifically developped, and by the interfacing adatpter PRODAT-03. The software includes a window-type program by which the operator is guided through the operations to be executed. Once the data are inputed, a few seconds is the time necessary to complete a configuration cycle. The parameters which is possible to configure are illustrated in the "Configuration options" in the page here at side. Furthermore it is possible, in the same phase, to program the "zero" and the "full scale" values. The calibrationof the device is made automatically, with the maximum accuracy, without the need of any mechanical regulation. The configuration is normally made at the factory in conformity to the customer' s order or, alternatively, in one of the most used configuration: DAT4035 / Pt100-0..200C / S.L. / 3-wire / 4..20mA / Upscale. The device can be reconfigured for any number of times. This operation is possible also when the device is operating in the plant or in the field because it is possible, by software, to interrupt momentarily the normal operation which restarts automatically after the configuration. In the case that the power supply unit is not avaible, the transmitter can be configured using a 9 V battery. The complete configuration system (which includes: interface module PRODAT-03 and software) is supplied at economical price.

DAT 4035
Custom execution on request

PRODAT-03 123

DAT 4035

DAT 4035 Technical Specifications


( typical @ 25C and in the nominal conditions )

Input
RTD Input PT100 PT1000 NI100 NI1000 TC Input J K S R B E T N Voltage Input mV mV V Min -200C -200C -60C -60C Max 850C 200C 180C 150C Span Min 50C 50C 50C 50C

Output
Current Output Signal range Load Resistance (4 - 20 mA) or (20 - 4 mA) (see Load Characteristic)

Accuracy
Linearity TC RTD

Min -200C -200C -50C -50C 400C -200C -200C -200C

Max 1200C 1370C 1760C 1760C 1820C 1000C 400C 1300C

Span Min 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV

0.2 % (1) 0.1 % (1)

Calibration RTD The larger of Res. Low The larger of Res. High The larger of mV, TC The larger of V The larger of Input current The larger of Cold junction comp. Output current Thermal Drift Full Scale 0.01%/C Cold junction Compensation

0.1%(1) and 0.2 C 0.1%(1) and 0.15 Ohm 0.2%(1) and 1 Ohm 0.1%(1) and 18 uV 0.1%(1) and 2 mV 0.1%(1) and 6 uV 0.5 C 7 uA

Min -100 -400 -10V

Max +700 +400 +10V

Span Min 2 mV 2 mV 500 mV

0.01%/C

Potentiometer Range Min Ohm 20 Ohm 200 KOhm 0.50 Resistance Input Min Low 20 Ohm High 300 Ohm Current Input mA

Max 200 500 50

Span Min 10% 10% 10%

Common data
Supply Supply Voltage Isolation Voltage Polarity protected 10 - 32 Vdc 2000 Vac for 60 Sec 60 Vdc

Max 300 Ohm 2000 Ohm

Span Min 10 Ohm 200 Ohm

Temperarture & Humidity Ambient Temperarure Humidity (not condensig)

-20 C to +70 C 0 to 90%

Min -10mA

Max +24 mA

Span Min 2 mA

Input impedence TC, mV V Current

EMC Emission EN50081-2 Immunity EN50082-2 RF Immunity tested for 10V/m up to 1000MHz Response time Rise time(10 - 90 %) Housing Material Mounting Weight

>/=10 MOhm >/= 1 MOhm 50 Ohm

0.4 sec. approx.

Lead wire resistance influence TC, mV ,V >/=0.8uV/Ohm RTD 3-wire 0.05%/Ohm (50 Ohm max) (2) RTD 4-wire 0.005%/Ohm (100 Ohm max) RTD Sensor Current Typical

Selfestinguish plastic DIN B head or bigger Approx. 50 g

Note:(1) of input span 0.350 mA


(2) Balancing required

EDIZ.10.00-REV.00
La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

124

Isolated smart signal conditioner DAT 4135


FEATURES RTD, TC, mV, V, mA, Resistor and Potentiometer input Voltage and current output Galvanically isolated Configurable by Personal Computer High accuracy and performance's stability On-field reconfigurable In compliance with EMC standards - CE Mark DIN rail mounting Available as configured device on user specifications APPLICATIONS Temperature Monitoring and Control for: - Process Controls - Automation Systems - Energy sources management

GENERAL INFORMATION
Introduction The DAT 4135 is a "smart" conditioner capable to perform many functions such as: Linearized temperature measurement with thermocouple or RTD sensors. Conversion of a linear resistance variation to a standard analog current or voltage signal. Conversion of a voltage signal, even coming from a potentiometer connected to its input, to a current or voltage linearized signal. Its very thin profile allows to mount a "smart" conditioner with galvanic isolation even at a pitch of only 12.5 mm on the DIN rail. General The device is built around a microprocessor core which controls any device function in a continuos and reliable mode by an efficient program developped. The unit can be configured to accept input from a wide range of sensors and electrical parameters and to supply in the output a current or voltage signal. Thanks to its versatility of use, it greatly reduces the warehouse stock satisfying a wide variety of needs; thus it offers immediate and evident economical advantages. By means of its continuos self calibrating operation, controlled by the microprocessor, the device guarantees an excellent accuracy and very stable measurement, both in time and in the operating temperature. Further, with this operating mode, the device is not longer subject to the usual variations of the circuit parameters. The 2000 Vac galvanic isolation, removing all ground loop effects as the input is electrically and physically isolated from the loop power supply, allows the use of the conditioner even in the heavy environmental conditions found in the industrial applications. The units are manufactured by using high quality and high precision electronic components which are assembled by the SMD technology; Both of these elements are the indispensable tools to realize a very reliable device. The DAT 4135, developped, manufactured and tested in strict accordance with the quality assurance standard ISO 9001 / EN 29001, is in compliance with the directive 89/336/CEE on the electromagnetic compatibility and the CE mark confirms the compliance of the product. The device is housed in a rough self estinguish plastic container suitable for mounting on DIN rails. Input types The DAT 4135 is configurable for any of the following input types: - RTD input for linearised PT100, PT1000, Ni100 and Ni1000. The cable compensation is possible by 3 or 4 wire connection. - Thermocouple input for 8 different types. The Cold Junction Compensation is selectable as internal or external. - Current input from -10 to +24 mA. - Voltage input up to -400/+700 mV or up to +/-10 V - Resistance input for linear resistance measurement from 20 Ohm to 2 KOhm with 3 or 4 wire compensation. - Potentiometer input from 20 Ohm to 50 KOhm. Output Programmable current or voltage ouput in the 0 to 20 mA or 0 to 10 v range. Programmable Sensor Burnout as "Upscale" or "Downscale". Short circuit protection is provided on the output. Set-Up All the configurable functions and parameters are easily programmed by means of a PC with a software package, named PROSOFT, developed . This "guide lines menu" type program operates under "Windows95TM" on a PC which communicate, via an interface adapter, with the DAT 4135. The adapter is connected through a cable to an apposite connector situated on the conditioner ( for more detailed information, see the figure in the next page). IMPORTANT: On request the transmitter can be supplied configured for the desired sensor type and calibrated for the specific range as defined in the order ( see "HOW TO ORDER ").

Custom execution on request

125

Configuration options for DAT4135 Conditioner (use this checklist when ordering configurated units):
ORD. CODE
RTD type: O O O O Pt100 Ni100 Pt1000 Ni1000 TC type: O O O O O O O O type J type K type S type R type B type E type T type N

INPUT
Resistance range: 20 Ohm to 2000 Ohm Potentiometer range: O 20 Ohm to 200 Ohm O 200 Ohm to 500 Ohm O 0.5 Kohm to 50 Kohm
ZERO: SPAN:

Range:

Range:

Range:

Voltage input range: O +/- 400 mV with input applied on L terminal O +/- 10 V with input applied on E terminal
Range:

Current input range: -10 to 24 mA

Range:

O Standard linearization RTD, TC

Linearization:

O No linearization O Customer linearization (specify):

Linearization:

RTD options: TC options: Res. Options:

O 2-wire O 3-wire O 4-wire

O Intern. CJC O 2-wire O Extern. CJC O 3-wire O 4-wire

OUTPUT
Output range:

O 0 - 20 mA O 20 - 0 mA O Special

O 4 - 20 mA O 20 - 4 mA

O 0-5V O 5-0V

O O

0 - 10 V 10 - 0 V

Sensor Burnout:

O Upscale O Downscale

HOW TO ORDER: A-Not configured device: DAT4135 Code: A B C D E B-Configured device: DAT4135 / TC J-50..600C / S.L. / Int. C.J.C. / 0..10V / Upscale* (*)The above is an example of how to order a conditioner for TC type J sensor, operating in the 0 to 600C range, with standard
linearization, with internal C.J.C., with an output of 0 to 10 V and with upscale sensor burnout.

MECHANICAL DIMENSIONS (mm.)


I L

G H

98

12.5

90

DAT4135
Custom executiom on request

126

DAT 4135 BLOCK AND WIRING DIAGRAM


I L G H E F A /D MUX CPU M Q Pow er S u p p ly R N

CONFIGURATION
This operation is carried out, using a Personal Computer with "Windows95" operating system, by the software PROSOFT, specifically developped, and by the interfacing adatpter PRODAT-03. The software includes a window-type program by which the operator is guided through the operations to be executed. Once the data are inputed, a few seconds is the time necessary to complete a configuration cycle, while the time necessary for the introduction of data is some ten of seconds. The parameters which is possible to configure are illustrated in the "Configuration Scheme" in the page here at side. Furthermore it is possible, in the same phase, to program the "zero" and the "full scale" values. The calibrationof the device is made automatically, with the maximum accuracy, without the need of any mechanical regulation. The configuration is normally made at the factory in conformity to the customer' s order or, alternatively, in one of the most used configuration: DAT4135 / Pt100-0..200C / S.L. / 3-wire / 4..20mA / Upscale. The device can be reconfigured and reprogrammed for any number of time. This operation is possible also when the device is operating in the plant or in the field because it is possible, by software, to interrupt momentarily the normal operation which restarts automatically after the configuration. The complete configuration system (which includes: interface module PRODAT-03 and software) is supplied at economical price.

DAT 4135

PRODAT-03

DAT4135
Custom execution on request

127

DAT 4135 Technical Specifications


( typical @ 25C and in the nominal conditions )

Output
Current Output Signal range Load Resistance Voltage Output Signal range Load Resistance Short circuit current (0/4 - 20 mA) or (20 - 4/0 mA) 650 Ohm max. (0 - 5/10 V) or (10/5 - 0 V) 3.5 K Ohm min. 20 mA approx. TC RTD

Input
RTD Input PT100 PT1000 NI100 NI1000 TC Input J K S R B E T N Voltage Input mV mV V Min -200C -200C -60C -60C Max 850C 200C 180C 150C Span Min 50C 50C 50C 50C

Accuracy
Linearity

Min -200C -200C -50C -50C 400C -200C -200C -200C

Max 1200C 1370C 1760C 1760C 1820C 1000C 400C 1300C

Span Min 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV 2 mV

0.2 % (1) 0.1 % (1)

Min -100 -400 -10V

Max +700 +400 +10V

Span Min 2 mV 2 mV 500 mV

Calibration RTD The larger of Res. Low The larger of Res. High The larger of mV, TC The larger of V The larger of Input current The larger of Cold junction comp. Output current Output voltage Thermal Drift Full Scale 0.01%/C Cold junction Compensation

0.1%(1) and 0.2 C 0.1%(1) and 0.15 Ohm 0.2%(1) and 1 Ohm 0.1%(1) and 18 uV 0.1%(1) and 2 mV 0.1%(1) and 6 uV 0.5 C 7 uA 5 mV

Potentiometer Range Min Ohm 20 Ohm 200 KOhm 0.50 Resistance Input Min Low 20 Ohm High 300 Ohm Current Input mA

0.01%/C

Max 200 500 50

Span Min 10% 10% 10%

Common data
Supply Supply Voltage 18 - 30 Vdc Supply current 40 mA at 24 Vdc Isolation Voltage 2000 Vac for 60 Sec Polarity protected 60 Vdc Temperarture & Humidity Ambient Temperarure -20 C to +70 C Humidity (not condensig) 0 to 90% EMC Emission EN50081-2 Immunity EN50082-2 RF Immunity tested for 10V/m up to 1000MHz Response time Rise time(10 - 90 %) 0,4 sec. approx. Housing Material Mounting Weight

Max 300 Ohm 2000 Ohm

Span Min 10 Ohm 200 Ohm

Min -10mA

Max +24 mA

Span Min 2 mA

Input impedence TC, mV V Current

>/=10 MOhm >/= 1 MOhm 50 Ohm

Lead wire resistance influence TC, mV ,V </=0.8uV/Ohm RTD 3-wire 0.05%/Ohm (50 Ohm max) (2) RTD 4-wire 0.005%/Ohm (100 Ohm max) RTD Sensor Current Typical

Selfestinguish plastic DIN B head or bigger Approx. 50 g

Note:(1) of input span


(2) Balancing required

0.350 mA EDIT.10.00-REV.00

La societ si riserva il diritto di modificare in tutto o in parte le caratteristiche dei propri prodotti senza alcun preavviso Factory reserves its right to modify the characteristics of its products totally or in part without warning at any time.
Custom executiom on request

128

THERMOCOUPLES

The certifications and calibrations program for: Thermocouples and RTDs


RTD S

LA TERMOTECNICA

Thermometric measurement chains, sensor plus indicator Temperature calibrators Indicators Plants, thermal mapping, thermal profiles
Company quality assurance systems were set up in accordance with ISO 9001, 9002, 9003 specifications starting from 1987. Other guidance regulations are applied to specific industrial sectors such as GMP (pharmaceutical and medical technologies) or QS9000 (automotive), etc. However, any company, also engaged in supplying services (banks, insurance companies, hospitals, etc.) can apply ISO quality assurance systems. All ISO guidelines and specifications specifically require the introduction and maintenance of calibration or testing systems at the companies.

The calibration certificates are fully compliant with the criteria established by QS regulations ISO 9001 ISO 10012-1 GMP FDA QS 9000 is the best compromise between quality and cost that the LA TERMOTECNICA calibration laboratories are able to offer. are available in Italian and English as they are valid and recognized in all countries where ISO standards are in force and applied.

129

BOLL.N01-0798_ltcal

THERMOCOUPLES

LA TERMOTECNICA

RTD S

Are low cost calibration certificates, an alternative to S.I.T. (Servizio Italiano di Taratura Italian Calibration Service) certificates. However, the calibration procedures have been carried out in accordance with EAL-R2 (European cooperation for Accreditation of Laboratories) guidelines and with UNI CEI EN 45000 specifications (general criteria for the operation of testing laboratories).

Calibrations based on comparison with master samples in the temperature range from 40 to +1064C.
Single element thermopouples
Range
0 . . 1064 C 0 . . 600 C 0 . . 250 C 0 . . 100 C -40 . . 40 C

n points Tabulation
5 4 3 3 3

O rder code
XS TC51SSR XS TC42SSR XS TC33SSR XS TC34SSR XS TC35SSR

yes yes yes yes yes

-Additional points on request. -Tem perature points m ust be indicated w hen ortering.

Single element RTD s

Range
0 . . 400C 0 . . 250 C 0 . . 100 C -40 . . 40 C

n points Tabulation
4 3 3 3

Order code
XS P46SSR XS P43SSR XS P34SSR XS P35SSR

yes yes yes yes

-Additional points on request. -Tem perature points m ust be indicated w hen ortering.

The calibrations are carried out by specialized personnel in our thermometric laboratory according to the following procedures -40 .. +40C
In liquid thermostat for comparison with platinum resistance master temperature sensor

+40 .. +250C

in silicone fluid thermostat for comparison with platinum resistance master temperature sensor

+250 .. +600C

In melted salt thermostat for comparison with platinum resistance master temperature sensor

+600 .. +1064C

In oven with comparison block for comparison with platinum resistance master thermocouple

130

BOLL.N01-0798_ltcal

THERMOCOUPLES

LA TERMOTECNICA

RTD S

Are low cost calibration certificates, an alternative to S.I.T. (Servizio Italiano di Taratura Italian Calibration Service) certificates. However, the calibration procedures have been carried out in accordance with EAL-R2 (European cooperation for Accreditation of Laboratories) guidelines and with UNI CEI EN 45000 specifications (general criteria for the operation of testing laboratories).

Calibrations based on comparison with master samples in the temperature range from 40 to +1064C.

The measurement chain is the thermometric system consisting of a temperature detector system plus sensor (recorder indicator temperature detector, etc.) Temperature detectors and sensors of any brand or model can be certified provided they are sent to our laboratories accompanied by any instructions for use manuals. The certificate indicates the values measured, the actual values and the deviation in C recorded at each measurement point in a table.

Range
0 . . 1064 C 0 . . 600 C 0 . . 250 C 0 . . 100 C -40 . . 40 C

n points Tabulation
5 4 3 3 3

O rder code
XC 5TCRS XC 4TCRS XC 3TCRS XC 3TCRS XC 3TCRS

no no no no no

-Additional points on request. -Tem perature points m ust be indicated w hen ordering.

The calibrations are carried out by specialized personnel in our thermometric laboratory according to the following procedures -40 .. +40C
In liquid thermostat for comparison with platinum resistance master temperature sensor

+40 .. +250C

in silicone fluid thermostat for comparison with platinum resistance master temperature sensor

+250 .. +600C

In melted salt thermostat for comparison with platinum resistance master temperature sensor

+600 .. +1064C

In oven with comparison block for comparison with platinum resistance master thermocouple

131

BOLL.N01-0798_ltcal

THERMOCOUPLES

LA TERMOTECNICA

Are low cost calibration certificates, an alternative to S.I.T. (Servizio Italiano di Taratura Italian Calibration Service) certificates. However, the calibration procedures have been carried out in accordance with EAL-R2 (European cooperation for Accreditation of Laboratories) guidelines and with UNI CEI EN 45000 specifications (general criteria for the operation of testing laboratories).

RTD S

Certification of calibration systems for thermocouple sensors consists in running of tests which assess the performance of the calibration instrument both as regards measurement of thermoelectromotive forces (EMF) and as measurement of these. To do this, voltage calibrators set by the national center ISTITUTO NAZIONALE G. FERRARIS are used which assures traceability of the master samples used. Usually, it is sufficient to calibrate an instrument on one or two scales (where scale means a type of linearization, for example TC K and/or TC J). However, the calibrators can be certified on any scale and for any type of thermocouple (J K T R S B C G D U L N E F) on request

Measurement/Simulation. n points Tabulation 1 scale (any type of


thermocouple) 10 10 6

Order code
XC 10TCRN XC 12TCRN

no. no no

2 scale (any type of thermocouple)


additional scale ( any type of thermocpuple)

-Additional scale on request. -Temperature points must be indicate when ordering.

132

BOLL.N01-0798_ltcal

THERMOCOUPLES

LA TERMOTECNICA

Are low cost calibration certificates, an alternative to S.I.T. (Servizio Italiano di Taratura Italian Calibration Service) certificates. However, the calibration procedures have been carried out in accordance with EAL-R2 (European cooperation for Accreditation of Laboratories) guidelines and with UNI CEI EN 45000 specifications (general criteria for the operation of testing laboratories).

RTD S

Any type of temperature indicator, thermo-regulators, recorders, dataloggers, both portable and fixed can be calibrated provided they are preset for thermocouple input (J K T R S B C G D U L N E F) or RTDs (PT100-PT1000PT25-Ni1000-Ni10). To do this, voltage calibrators set by the national center ISTITUTO NAZIONALE G. FERRARIS are used which assures traceability of the master samples used.

Measurement 1 scale ( any type of


therm ocouple) therm ocouple)

n points Tabulation
10 10 6

Order code
XC 10TIRN XC 12TIRN

no no no

1 scale ( any type of


addictional scale ( any type of therm ocouple)

-Addictional points on request. -Tem perature points m ust be indicated w hen ortering.

133

BOLL.N01-0798_ltcal

THERMOCOUPLES

Are low cost calibration certificates, an alternative to S.I.T. (Servizio Italiano di Taratura Italian Calibration Service) certificates. However, the calibration procedures have been carried out in accordance with EAL-R2 (European cooperation for Accreditation of Laboratories) guidelines and with UNI CEI EN 45000 specifications (general criteria for the operation of testing laboratories).

LA TERMOTECNICA

RTD S

In view of the particular characteristics of each installation, on-site checking of systems requires a specific approach to each individual case. Certain types of tests that can be considered common and applicable in most cases can however be identified. Thermal mapping In closed process plants (chamber furnaces, muffle furnaces, crucible furnaces, incinerators, etc.), uniformity of the temperature inside the hot or treatment chamber must be checked. In these cases, up to 20 sensors can be positioned inside to perform a typical cycle. The related data are stored in the form of graphs and/or digital data using an acquisition system connected to a PC that permits customized post-processing. Thermal profiles In pass-through systems (tunnel, carpet, bogie type furnaces, etc.), a check must be made on conformity of the temperature reached by the material to be treated both as regards absolute value (value reached) and in terms of dwell time. Where possible, probes (fastened to the drive system or to the material) that pass through the entire plant are used connected to an acquisition system with a PC that permits graphic or digital processing. Alternatively, where this is not possible due to the winding path followed, wireless systems also resistant to high temperatures are used which, when connected subsequently to a PC; provide the data saved in an internal memory.

134

BOLL.N01-0798_ltcal

Technical notes
Thermocouples

THERMOCOUPLES

Principle of operation
A thermocouple is a passive electric transducer (as it does not require powering). The physical principle on which it is based is known as the Seebeck effect (from the name of the scientist who discovered it). Thermocouples are made of two dissimilar metal wires joined at their measuring end. If the two junctions are at a different temperature, a current proportional to the difference in temperature between the two junctions will start to flow in the circuit.

RTD s

i T1 i=F(t1;t2) T2

LA TERMOTECNICA

Obviously, when the circuit is interrupted, a thermoelectromotive force is generated, the polarity and intensity of this force depends (t1-t2 being equal) only on the nature of the two metals used. The junction that senses the temperature is known as the hot junction and the measurement junction is known as the cold or reference junction.

f.e.m. T1 f.e.m.=F(t1;t2) T2

From a practical point of view, to measure the absolute value of a temperature, the temperature of the cold junction must be known so as to calculate the value of the temperature of the hot junction according to difference between these. In an industrial environment, this task is usually performed automatically by the measurement system, whether this is a thermo-regulator, a digital thermometer, a recorder or other. It is important to note that the connection cables must be made of the same material as the sensor and also that connections must be made complying with polarity.

termocoppia

cavi indicatore
1 5 0

Main type of thermocouples


Type material
S R B J K T N E Pt vs. Pt10%Rh Pt vs. Pt13%Rh Pt6%Rh vs. Pt30%Rh Fe vs. C o C r. vs. Al C u vs . C o Nicrosil vs. Nisil C r. vs. C o

Range [C ]
-50 . . +1760 -50 . . +1760 0 . . +1820 -200 . . +760 -270 . . +1370 -270 . . +400 -270 . . +1300 -270 . . +1000

Description
Noble me tal the rmocouple . Re siste nce to high te mpe rature , ine rt or oxidizing atmosphe re . Noble me tal the rmocouple . Re siste nce to high te mpe rature , ine rt or oxidizing atmosphe re . Noble me tal the rmocouple . Re siste nce to high te mpe rature , ine rt or oxidizing atmosphe re . Base me tal the rmocouple . For ave rage range te mpe rature in re ducing , vacuum and ine rt atmosphe re . Base me tal the rmocouple , thank to wide range and low cost, re sult the most use d in industry. Do not use in re duce nt atmosphe re . Base me tal the rmocouple . f or pre cise me asure me nt at ave rage low te mpe rature , in oxidizing or re duce nt atmosphe re . Base me tal the rmocouple . I n option to K type , we re more pre cision is ne e de d. Base me tal the rmocouple . Highe st EMF change pe r de gre e , to be use d in oxidizing or ine rt atmosphe re , limite d use in vacuum or ine rt.

135

Technical notes
Thermocouples

THERMOCOUPLES

Construction

RTD s

Two ways may be used to construct a thermocouple

LA TERMOTECNICA

With mineral insulation Magnesium oxide insulated cables are used which consist of an exter nal metal sheath housing the wires which are insulated from each other and in relation to the outer sheath with compressed MgO powder. With this system, sturdy sensors are obtained featuring high level tolerance to shock and vibrations and much higher performance than those constructed according to the classical method. They can also be bent thus adapting readily to housings with winding paths. Speed of response, possibility of miniaturization and service life are other particular characteristics of mineral insulated sensors.

MgO powder

Protection sheath

Thermocouple

With calibrated wires and insulators The wires are insulated by an external rigid sheath using ceramic in sulators. The external sheath protect the wires against gases or corrosive agents that may be present in the measurement environment. Selection of wires of suitable diameter and type according to harsh ness of the environment is also important while ceramic or fiberglass insulators can be used according to the maximum service tempera ture to be reached.
Ceramic insulator

Protection sheath

Thermocouple

A performance comparison
spe e d of re sponse
100% 100%

re siste nce to vibration


100%

re siste nce to pre ssure


100%

se rvice life

75

75

75

75

50

50

50

50

25

25

25

25

Mgo

w ire s and insulat.

Mgo

w ire and insulat.

Mgo

w ire s and insulat. i

Mgo

w ire s and insulat.

136

Technical notes
Thermocouples

THERMOCOUPLES

Types of junction

RTD s

There are three possible versions of the hot or sensing junction: Hot junction Ungrounded hot junction The junction is not in contact with the external sheath. This means that it is generally immune to disturbances cause by stray currents generated by magnetic fields or equipment working under voltage. It is a good compromise between protection against disturbances and speed of response.

LA TERMOTECNICA

Insulated

Grounded hot junction The junction is an integral part of the weld that seals the sensing tip of the thermocouple. These thermocouples have the fastest response times but, because of the ground connection of the junction, they may be affected by distur bances on the output signal. In some cases, this type of junction cannot be used if the measure ment system is not insulated.

Gorunded

Exposed hot junction The junction is exposed to the atmosphere of the measurement area. Response time is by far the highest of the three solutions with the same diameter of the outer sheath. It is not suitable for measurements at high temperatures and in aggres sive environments.

Exposed

Response time
The results of a study carried out in laboratory conditions intended to establish the response times of thermocouple sensors are provided below. The time constant refers to the study in ambient pressure and temperature conditions in a flow of air moving at 20 m/s for the thermocouple shown in figure TR1. The time constant or response time is defined as the time taken by the sensor to reach 63% of an instantaneous temperature variation. The time constant is not tied to the difference in temperature of a specific thermal gradient.

Bare wire

MgO grounded

Bare wire twisted

MgO insulated

FIG. tr1

137

Technical notes
Thermocouples

THERMOCOUPLES

The data are presented in the form of graphs in the table below. Knowing the diameter of a sensor, it is easy to estimate the corresponding time constant and, assuming the response time expected from a thermocouple, it is equally simple to calculate the diameter able to comply with this condition.

LA TERMOTECNICA

RTD s

Note: the data indicated refer to thermocouples with type A or type B junctions (ref. fig. TR1); to estimate the response time of type C or D junction sensors (ref. Fig. TR1), the time constant is higher and must be corrected multiplying by a factor of 1.5.

1.2

2.2

1.0

2.0

Costante di tempo [sec.]

0.8

1.8

0.6

1.6

0.4

1.4

0.2

1.2

0.1

0.2

0.3

0.4

0.5

0.6

0.6

0.65

0.7

0.75

0.80

0.85

Wires or sheath diameter [mm]


12.0 90.0

Wires or sheath diameter [mm]

10.0

75.0

Costante di tempo [sec.]

8.0

60.0

6.0

45.0

4.0

30.0

2.0

15.0

1.0

1.5

2.0

2.5

3.0

3.5

3.0

4.0

5.0

6.0

7.0

8.0

Wires or sheath diameter [mm]

Wires or sheath diameter [mm]

138

Technical notes
Thermocouples

THERMOCOUPLES

Precision and class of tolerance


LA TERMOTECNICA produces in accordance with various reference standards, that is to say:

RTD s

UNI 7938 ANSI MC96 IEC 584

LA TERMOTECNICA

There are two precision classes: Class 1 (special) Class 2 (standard) The permissible tolerance values for the various types of thermocouple at the various temperatures are indicated in the table below:

class 1
spe cial

class 2

standard 1 C o 0. 0075x| t| -40 . . +350 C

the rmocouple T the rmocouple E J K the rmocouple R/S B


-40 . . +800 C -40 . . +750 C -40 . . +350 C

0, 5 C o 0. 004x| t|

te mpe rature range in w itch the tolle rance is valid 1, 5 C o 0. 004x| t| -40 . . +900 C -40 . . +750 C -40 . . +1200 C 1, 5 C o 0. 0025x| t| 0 . . +1600 C +600 . . 1700 C te mpe rature rnge in w itch the tolle rance is valid 0 . . +1600 C 2, 5 C o 0. 0075x| t|

te mpe rature range in w itch the tolle rance is valid

-40 . . +1000 C 1 C o [ 1+ 0. 003( t-1100) ] C

As can be noted, the maximum and minimum error that a sensor must not exceed to be considered in tolerance is expressed as absolute value in C or as percentage value of the temperature to be measured; obviously, the larger of the two is applied (according to the temperature). Example1: if we measure 184C with a class 2 type K sensor, the maximum measurement error may be: +/- 2.5C (as 2.5 is larger than 0.0075 [184] = 1.38C). EExample: if we measure 981C with a class 1 type K sensor, the maximum measurement error may be: +/- (0.004[981]) = +/- 3.92C (as 3.92 is higher than 1.5C).

600 C

1700 C
+/- 4,25 C

0 C

600 C

1600 C
+/- 4 C

-40 C

333 C

900 C
+/- 6,75 C

+/- 1,5

+/- 1,5

type B -40 C 333 C 750 C


+/- 5,62 C

type R/S -40 C 333 C 1200 C


+/- 9 C

type E -40 C 133 C 350 C


+/- 2.6 C

+/- 2,5

+/- 2,5

type J

type K

Ttype T

139

+/- 1

+/- 2,5

Technical notes
Thermocouples

THERMOCOUPLES

Linearity and conversion tables


According to the reference standard, there are polynomial linear functions that provide the mathematical relationship that links temperature and thermoelectromotive force (EMF). Each TC, as defined by the tables, complies with a mathematical relationship which is generally of the following type:

LA TERMOTECNICA

RTD s

E=

i=1

ai(t90)i

Where ai are calculated coefficients and t90 is the temperature measured (t90 indicates that the STI 90 temperature scale is used). Usually the scale range of a thermocouple cannot be reproduced using a single polynomial curve; this means that there are several polynomial curves for the same thermocouple.

80 E

0.08 E

Seebeck coefficent [mV/C]

60

T 0.06

f.e.m. [mV]

K J

40

0.04

20

S R

0.02

S R

500

1000

1500

200

-500

500

1000

1500

Temperature [C]

Temperature [C]

For further information check conversion tables f.e.m. [mV] vs. Temperature [C].

140

Technical notes
R T D s

THERMOCOUPLES

Principio di funzionamento
The physical principle on which RTDs are based is the variation in resistance as temperature varies, a common characteristics of all metals. In industry, the two most frequently used metals are Nickel and Platinum due to their high level sensitivity (variation in resistance for each C) and stability in time. Compared with almost all other electric transducers (thermocouples, thermistors) RTDs offer considerable advantages as regards measurement precision and repeatability. There are three categories of platinum thermometers according to the type of construction techniques used. Ceramic (max T 750C) termoresistenza ceramica

LA TERMOTECNICA

RTD s

A platinum wire is wound and encapsulated in a ceramic coating. Used to construct high precision thermometers or where RTDs must be used to measure high temperatures. Glass (max T 600C) termoresistenza in vetro

A platinum wire is wound on a glass support and then encapsulated in an external protective sheath also made of glass. Use in applications where precision and repeatability are indispensable (master thermometers). Thin film (Max T 450C) A microfilm of platinum is deposited by diffusion on a ceramic support; an electric circuit with suitable electrical resistance characteristics is created subsequently using laser technology.

termoresistenza a film sottile

Connections and measurement method


An RTD is a traducer that must be powered as, in order to read the value of the resistance, the measurement system requires a fixed value current that is made to flow inside the measurement circuit while the voltage drop must be read at the same time. At this point, the resistance value is calculated according to Ohms law. There are three ways of wiring the measurement circuit and therefore three possible configurations of RTD sensors:

white

white

white

red

red

white

red

Pt100

red

Pt100

Pt100

Two wire connection

Three wire connection

Four wire connection

141

red

Technical notes
R T D s

THERMOCOUPLES

- 2-wire technique This is the least precise solution as the measurement system is unable to compensate the error introduced by the length of the connection cable (line resistance). In an industrial environment, it is usually restricted to applications requiring very low preci sion and it is good practice not to consider this technique even for general applications. - Three-wire technique
5

evaluating the eror due to the resistence of wire using the two wire connection tecnique.
Cross section 0.35 mm2 Cross section 0.5 mm2 0.35 0.5 0.8 4 1 Cross section 0.8 mm2 Cross section 1 mm2

LA TERMOTECNICA

RTD s

Error [C]

Most industrial applications use the three-wire technique as it represents the best compromise between cost and perfor mance. From a more practical point of view, the three-wire connection makes it possible to eliminate the line resistance error as the voltage drop from which the resistance value is obtained is measured independently. - Four-wire technique This is the connection method that affords the best reading precision and is used mainly for laboratory measurements or where high level reliability is required (primary or secondary master thermometers).

10

20

30

40

50

Connection lenght [m]

Construction
As for thermocouple sensors, there are two possible methods of construction: - With mineral insulation Magnesium oxide insulated cables are used consisting of an external metal sheath housing the wires which are insulated from each other and in relation to the outer sheath with compressed MgO powder. This system makes it possible to obtain rugged sensors with high level tolerance to shock and vibrations and with much higher performance than those constructed using the classical method. They can also be bent thus adapting readily to housings with windng paths. Speed of response, possibility of miniaturization and service life are other particular characteristics of mineral insulated sensors. - With calibrated wires and insulators The wires are insulated by an external rigid sheath using ceramic insulators. The outside sheath must afford suitable protection of the wires against gases or corrosive agents that may be present in the mea surement environment. Selection of wires of suitable diameter and type according to harshness of the environment is also important while ceramic or fiberglass insulators can be used according to the maximum service temperature to be reached.
Ceramic insulator MgO powder

Protection sheath

Termoresistence

Protection sheath

142

Termoresistence

Technical notes
R T D s

THERMOCOUPLES

A performance comparison

RTD s

spe e d of re sponse
100% 100%

re siste nce to vibration


100%

re siste nce to pre ssure


100%

se rvice life

LA TERMOTECNICA

75

75

75

75

50

50

50

50

25

25

25

25

Mgo

w ire s and insulat.

Mgo

w ire and insulat.

Mgo

w ire s and insulat. i

Mgo

w ire s and insulat.

Perecision and class of tolerance


LA TERMOTECNICA produces in accordance with various reference standards, namely: UNI 7937 DIN 43760 IEC 751 There are five precision classes: Class B Class A Class 1/3B Class 1/5B Class 1/10B The standards establish that it must be possible to calculate the maximum and minimum error that a sensor must not exceed to be considered in tolerance at each temperature measured. The absolute value of the error at each measurement temperature is obtained using the following formulas error class B error class A =+/- (0.30+0.005|T|) =+/- (0.15+0.002|T|) =+/- (0.10+0.0016|T|) =+/- (0.06+0.0010|T|) =+/- (0.03+0.0005|T|)

error class 1/3B error class 1/5B errore classe 1/10B

|T| is the absolute value of the temperature in Centigrade. Example: if we measure 125C with a class A sensor, the maximum measurement error is: +/- (0.15+0.002|125|) = +/- 0.4 C

143

Technical notes
R T D s
The error values in C and in Ohm are indicated in the table below for a number of temperatures for all the tolerance classes established.

THERMOCOUPLES

temp. [C ]

class B
C 1, 3 0, 8 0, 3 0, 8 1, 3 1, 8 2, 3 2, 8 3, 3 3, 6 Ohm 0, 56 0, 32 0, 12 0, 3 0, 48 0, 64 0, 79 0, 93 1, 06 1, 13 C

class A
Ohm 0, 24 0, 14 0, 06 0, 13 0, 20 0, 27 0, 33 0, 38 0, 43 0, 46

class 1/3B
C 0, 42 0, 26 0, 10 0, 26 0, 42 0, 58 0, 74 0, 90 1, 06 1, 14 Ohm 0, 16 0, 10 0, 04 0, 10 0, 16 0, 22 0, 29 0, 35 0, 41 0, 44

class 1/5B
C 0, 26 0, 16 0, 06 0, 16 0, 26 0, 36 0, 46 0, 56 0, 66 0, 71 Ohm 0, 10 0, 06 0, 02 0, 06 0, 10 0, 14 0, 18 0, 21 0, 25 0, 27

class 1/10B
C 0, 13 0, 08 0, 03 0, 08 0, 13 0, 18 0, 23 0, 28 0, 33 0, 36 Ohm 0, 05 0, 03 0, 01 0, 03 0, 05 0, 07 0, 09 0, 11 0, 13 0, 14

RTD s

-200 -100 0 100 200 300 400 500 600 650

0, 55 0, 35 0, 15 0, 35 0, 55 0, 75 0, 95 1, 15 1, 35 1, 45

LA TERMOTECNICA

Class B

Class A

Class 1/3B

Class 1/5B

Class 1/10B

5.0 4.5 4.0 3.5 3.0

5.0

4.0

3.0

Error (+/-) [C]

2.5 2.0 1.5 1.0 0.5

2.0
Class A Class 1/3B Class 1/5B

1.0

Class 1/10B

-200

-100

100

200

300

400

500

600

700

800

Measured temperature [C]

Linearity and conversion tables


According to the reference standard, sensors with a nominal resistance at 0C that varies between 5 and 1000 Ohm have been catalogued; however, the most widely used in an industrial environment are those with a resistance of 100 Ohm (Pt100) and those with resistance of between 500 and 1000 Ohm. The mathematical relationship that links nominal resistance Ro and resistance at a temperature t, Rt is as follows: -For temperatures in the range 200 .. 0C -For temperatures in the range 0 .. 850C Where the constants A, B and C have the following values: Rt/R0 = 1 + At + Bt2 + C(t-100)t3 Rt/R0 = 1 + At + Bt2 A = 3,90802 x 10-3 [ C-1 ] B = -5,80200 x 10-7 [ C-2 ] C = -4,27350 x 10-12 [ C-4 ]

144

Error (+/-) [C]

ss B Cla

Technical notes
General

THERMOCOUPLES

Criteria for selecting the protection sheath


As already mentioned, selection of the right type of protective sheath is extremely important in assuring correct functioning and long service life of the sensor regardless of whether this is a thermocouple or RTD. In some cases, if the material of the sheath is not selected correctly, this may result in downgrading of the initial calibration of the sensor during functioning at high temperature with therefore a significant measurement error. The most frequently used material for high and medium temperatures is stainless steel and this usually represents an excellent choice for most applications. However, specific materials may have to be used for certain particular applications in specific sectors of industry (oil industry, atomic industry, aircraft-marine, energy). In these cases, the standards to be referred to in order to make a suitable assessment of costs and quantity limits to be produced must be provided. The characteristics of the most widely used materials are described below: AISI 304 300 series stainless steel: is the ideal solution for medium temperatures for both thermocouples and RTDs. Good resistance to nitric acids, poor resistance to halogenated acids, moderate resistance to sulfuric acids. Temperature: Applications: max 650C - Food and drink processes - Chemical processes - Pharmaceuticals - Medical appliances - Containers of corrosive mixes

LA TERMOTECNICA

RTD s

- AISI 316 300 series stainless steel: widely used as an alternative to AISI 304 as it performs well at higher temperatures (1000C) and in particular due to its greater resistance to corrosive attack. Sensitive to the presence of sulfides, good resistance to phosphoric and acetic acids Temperature: Applications: max 850C - Parts of furnaces - Oil refining - Heat exchangers - Heaters

- AISI 310 300 series stainless steel of the refractory steels category: is suitable for applications in which the main problems are dwell time at high temperature and oxidation. Sensitive to the presence of sulfides. Temperature: Applications: max 1100C - Parts of furnaces - Incinerators - Supports for heaters - Sintered products

- AISI 446 400 series stainless steel with excellent corrosion resistance at very high temperatures. Its main characteristic is its resistance to sulfurous environments. Temperature: Applications: max 1100C - Parts of furnaces - Chemical industry - Pipes - Incinerators

- Inconel 600 Nickel and chromium based stainless steel, ideal for wide-scale use at high temperatures, resistant to corrosion by acids even at high temperatures. Excellent mechanical strength at high temperatures, not to be used in sulfurous atmospheres Temperature: Applications: max 1150C - Parts of furnaces - Nuclear power plants - Chemical and petrochemical - Machines for food products

145

Technical notes
General
Recommended protective sheaths according to application The following information is based on the long-term hands-on experience of our technicians. The table should be considered a general guide. In specific situations (on any type of system), unforeseen situations may occur such as the effective presence of aggressive and corrosive agents, vibrations, thermal cycles, etc. Heat treatements Annealing up to 700 C above 700 C Case-hardening up to 820 C above 820 C Nitriding Salt bath Cyanohydrides Neutral hight speed Non ferrous material Alluminium Melting furnaces Heat treatements Brass/Bronze Magnesium Zinc Cements Furnaces Klinker Ceramic Furnaces Dryers Glass Melting furnaces Heat treatements and firing Paper Printing machines Oil Refining towers Ducts Fractionating columns Energy Hot air Liquid gases Heaters Steam Boilers Incineritors up to 1100 C above 1100 C Food Cooking ovens Vegetable treatement Pasturization Chimical Acetic acid 50% (100C) Alcohol Ethylic (100 C) Methylic (100 C) Ammonium Nitrates Sulfides Hydrochlorides Barium Hydrochloride Iodide Solfite Butyl Calcium Chlorate Iodide Cromic acid Copper nitrate Formaldehyde Formic acid Gasoline Glucose Glycerin Glycol Hydrogen oeroxide (100 C) Lactic acid <5% (100 C) >10% (100 C) Natural gases Nitric acid <50% (20 C) <50% (100 C) >50% (100 C) Mineral oils Oxigen Phenoles Xylene Toluene Sodium Bicarbonate Carbonate Hydrochloryde Potassium Sulfate Permanganate Nitrate Chlorate Carbonate

THERMOCOUPLES

RTD s

AISI 316/AISI 310 AISI 446/Inc. 600 AISI 446/AISI 310 Inc. 600 Inc. 600/AISI 446 Nichel AISI 446 Ceramic

AISI 316 AISI 304 AISI 316 AISI 310/AISI 304 AISI 310/AISI 304 AISI 310/AISI 304 MONEL Acciaio Inc. 600 Copper AISI AISI AISI AISI AISI AISI AISI AISI AISI AISI AISI 316 316 316 304 316 316 304/AISI 316 304 304 304 316

LA TERMOTECNICA

Steel/Cast iron AISI 316/AISI 304 AISI 316 AISI 316/AISI 304 Acciaio Inc. 600/AISI 446 Inc. 600 Ceramic SiC/Ceramic Platino Ceramica/AISI 446 Inc. 600 AISI 316/AISI 446 AISI 304/AISI 316 AISI 304/AISI 316 AISI 304/AISI 316 AISI 304 AISI 446/Inc. 600 Inc 600/AISI 310 AISI 316 AISI 310 AISI 446 Ceramic/SiC AISI 304/AISI 316 AISI 304 AISI 316

AISI 316 Tantalio AISI 304 AISI 304 AISI 316 Tantalio AISI 316 AISI 304 AISI 304 Rame AISI 316 AISI 316 AISI 316 AISI 316 AISI AISI AISI AISI AISI 304/AISI 304/AISI 304/AISI 304/AISI 304/AISI 316 316 316 316 316

146

Technical notes
General

THERMOCOUPLES

Ceramic protection sheaths


Ceramic protection sheaths are used mainly to protect noble metal thermocouple sensors in very high temperature applications (>1200C) or as an alternative to the metal sheaths also for base metal thermocouples where the atmosphere is incompatible with use use of these. In addition to their resistance to very high temperatures, they are chemically inert and also feature good anti-abrasion characteristics and excellent di-electric rigidity. They are however not recommended for the following applications: - dipping in molten metal or salts - For overhanging assembly exceeding 1000 mm (vertical) or 6000 mm (horizontal) -In pressurized or vacuum systems -In systems liable to frequent thermal shocks The materials used to construct standard sensors are listed below: -Sillimantin (DIN VDE 0335 / 530) Refractory containing 75% alumina, is porous to gases and can operate up to temperatures of 1600C. Good resistance to thermal shocks, to be used as main sheath or as internal protection. -Pitagoras (DIN VDE 0335/610) One of the most economical gas-proof refractory materials with an alumina content of 60%; can be used up to temperatures of 1500C in corrosive environments; it however sensitive to the presence of hydrogen fluoride. To be used as external and internal protection. -Alumina (DIN VDE / 799) High quality refractory with very high content of Alumina (99.7%); excellent di-electric characteristics, resistance to aggressive reducing gases such as nitrogen, acids and alkalis, to nuclear radiation, to X-rays and UV rays. Chemically inert and non degassing in vacuum. Maximum recommended temperature 1800C.

LA TERMOTECNICA

RTD s

C eramic sheath selection table


Ope rating condition and maximum te mpe ratre Gase ous atmosphe re without hydrof luoric acid or alkalis, up to1400 Up to 1800 C in the abse nce of corrosive attack, in the pre se nce of alkaline vapors ( glass baths and ove ns f or ce ramic) up to 1600 C I n the pre se nce of ve ry high the rmal stre ss and up to 1600 C Raccome nde mate rial Pitagoras ( inte rnal) Pitagoras ( e ste rnal) Allumina ( inte rnal) Allumina ( e ste rnal) Allumina ( inte rnal) Sillimantin ( e xte rnal)

147

Technical notes
General
Fill in the form to requeste a quote for a non-standard or customized product. Company style (Name, address, Tel) Drowing

THERMOCOUPLES

RTD s

Application

LA TERMOTECNICA

date

quantity

parts/year

Thermocouple (cross with an X)


B E J K N R S T exposed special

Junction:

grounded

insulated standard double

class of tolerance: element:


single

RTD s (cros with an X)


Pt100 - Pt1000 - Pt500 - Ni100 - Ni1000 other, specify :

connection cable (if present) lenght (mt): color code: ANSI Cross section and munber of wires:

IEC

DIN

collegamento: 2 fili elemento:


singolo

3fili

4fili

Primary insulation: glass teflon silicone rubber. Pvc other: Secondary insulation: glass teflon silicone rubber. Pvc other: Shielding: tinned copper
stainlessSteel other:

classe di tolleranza: B A 1/2B 1/3B


doppio

Sheath quality and insulation insulation: MgO wires+insulators other:


faston etc.)

Sheath quality: 304SS 316SS 310SS Inc. 600 other: Indicate the connectiong system (fittings, flanges etc.)

Indicate the type of electrical connection (connectors,

Working enviroment (cross with an X) temperature: minimum[ C] atmosphere: Plant features: notes:
inert vibration oxidizing thermal shocks

maximum[ riducing other: vacuum

C]

continuos[

C]

148

LA TERMOTECNICA

THERMOCOUPLE

F.E.M. output of a K type thermocouple(Nikel/Cromium Vs.Copper/Nichel). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. cold junction 0 C C -200 -190 -180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 C C 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 C 0 -5,891 -5,730 -5,550 -5,354 -5,141 -4,913 -4,669 -4,411 -4,138 -3,852 -3,554 -3,243 -2,920 -2,587 -2,243 -1,889 -1,527 -1,156 -0,778 -0,392 0,000 0 0 0,000 0,397 0,798 1,203 1,612 2,023 2,436 2,851 3,267 3,682 4,096 4,509 4,920 5,328 5,735 6,138 6,540 6,941 7,340 7,739 8,138 8,539 8,940 9,343 9,747 10,153 10,561 10,971 11,382 11,795 12,209 0 -1 -5,907 -5,747 -5,569 -5,374 -5,163 -4,936 -4,694 -4,437 -4,166 -3,882 -3,584 -3,274 -2,953 -2,620 -2,278 -1,925 -1,564 -1,194 -0,816 -0,431 -0,039 -1 1 0,039 0,437 0,838 1,244 1,653 2,064 2,478 2,893 3,308 3,723 4,138 4,550 4,961 5,369 5,775 6,179 6,580 6,981 7,380 7,779 8,178 8,579 8,980 9,383 9,788 10,194 10,602 11,012 11,423 11,836 12,250 1 -2 -5,922 -5,763 -5,588 -5,395 -5,185 -4,960 -4,719 -4,463 -4,194 -3,911 -3,614 -3,306 -2,986 -2,654 -2,312 -1,961 -1,600 -1,231 -0,854 -0,470 -0,079 -2 2 0,079 0,477 0,879 1,285 1,694 2,106 2,519 2,934 3,350 3,765 4,179 4,591 5,002 5,410 5,815 6,219 6,620 7,021 7,420 7,819 8,218 8,619 9,020 9,423 9,828 10,235 10,643 11,053 11,465 11,877 12,291 2 -3 -5,936 -5,780 -5,606 -5,415 -5,207 -4,983 -4,744 -4,490 -4,221 -3,939 -3,645 -3,337 -3,018 -2,688 -2,347 -1,996 -1,637 -1,268 -0,892 -0,508 -0,118 -3 3 0,119 0,517 0,919 1,326 1,735 2,147 2,561 2,976 3,391 3,806 4,220 4,633 5,043 5,450 5,856 6,259 6,660 7,060 7,460 7,859 8,258 8,659 9,061 9,464 9,869 10,276 10,684 11,094 11,506 11,919 12,333 3 -4 -5,951 -5,797 -5,624 -5,435 -5,228 -5,006 -4,768 -4,516 -4,249 -3,968 -3,675 -3,368 -3,050 -2,721 -2,382 -2,032 -1,673 -1,305 -0,930 -0,547 -0,157 -4 4 0,158 0,557 0,960 1,366 1,776 2,188 2,602 3,017 3,433 3,848 4,262 4,674 5,084 5,491 5,896 6,299 6,701 7,100 7,500 7,899 8,298 8,699 9,101 9,504 9,909 10,316 10,725 11,135 11,547 11,960 12,374 4 -5 -5,965 -5,813 -5,642 -5,454 -5,250 -5,029 -4,793 -4,542 -4,276 -3,997 -3,705 -3,400 -3,083 -2,755 -2,416 -2,067 -1,709 -1,343 -0,968 -0,586 -0,197 -5 5 0,198 0,597 1,000 1,407 1,817 2,230 2,644 3,059 3,474 3,889 4,303 4,715 5,124 5,532 5,937 6,339 6,741 7,140 7,540 7,939 8,338 8,739 9,141 9,545 9,950 10,357 10,766 11,176 11,588 12,001 12,416 5 -6 -5,980 -5,829 -5,660 -5,474 -5,271 -5,052 -4,817 -4,567 -4,303 -4,025 -3,734 -3,431 -3,115 -2,788 -2,450 -2,103 -1,745 -1,380 -1,006 -0,624 -0,236 -6 6 0,238 0,637 1,041 1,448 1,858 2,271 2,685 3,100 3,516 3,931 4,344 4,756 5,165 5,572 5,977 6,380 6,781 7,180 7,579 7,979 8,378 8,779 9,181 9,585 9,991 10,398 10,807 11,217 11,630 12,043 12,457 6 -7 -5,994 -5,845 -5,678 -5,493 -5,292 -5,074 -4,841 -4,593 -4,330 -4,054 -3,764 -3,462 -3,147 -2,821 -2,485 -2,138 -1,782 -1,417 -1,043 -0,663 -0,275 -7 7 0,277 0,677 1,081 1,489 1,899 2,312 2,727 3,142 3,557 3,972 4,385 4,797 5,206 5,613 6,017 6,420 6,821 7,220 7,619 8,019 8,418 8,819 9,222 9,626 10,031 10,439 10,848 11,259 11,671 12,084 12,499 7 -8 -6,007 -5,861 -5,695 -5,512 -5,313 -5,097 -4,865 -4,618 -4,357 -4,082 -3,794 -3,492 -3,179 -2,854 -2,519 -2,173 -1,818 -1,453 -1,081 -0,701 -0,314 -8 8 0,317 0,718 1,122 1,530 1,941 2,354 2,768 3,184 3,599 4,013 4,427 4,838 5,247 5,653 6,058 6,460 6,861 7,260 7,659 8,059 8,458 8,860 9,262 9,666 10,072 10,480 10,889 11,300 11,712 12,126 12,540 8 -9 -6,021 -5,876 -5,713 -5,531 -5,333 -5,119 -4,889 -4,644 -4,384 -4,110 -3,823 -3,523 -3,211 -2,887 -2,553 -2,208 -1,854 -1,490 -1,119 -0,739 -0,353 -9 9 0,357 0,758 1,163 1,571 1,982 2,395 2,810 3,225 3,640 4,055 4,468 4,879 5,288 5,694 6,098 6,500 6,901 7,300 7,699 8,099 8,499 8,900 9,302 9,707 10,113 10,520 10,930 11,341 11,753 12,167 12,582 9 -10 -6,035 -5,891 -5,730 -5,550 -5,354 -5,141 -4,913 -4,669 -4,411 -4,138 -3,852 -3,554 -3,243 -2,920 -2,587 -2,243 -1,889 -1,527 -1,156 -0,778 -0,392 -10 10 0,397 0,798 1,203 1,612 2,023 2,436 2,851 3,267 3,682 4,096 4,509 4,920 5,328 5,735 6,138 6,540 6,941 7,340 7,739 8,138 8,539 8,940 9,343 9,747 10,153 10,561 10,971 11,382 11,795 12,209 12,624 10 CABLE COLOR CODING IEC 584-3 CABLE COLOR CODING ANSI TEMPERATURE RANGE (-270 +1370 C)

LA TERMOTECNICA
C 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600 610 620 630 640 650 660 670 680 690 700 710 720 730 740 750 760 770 780 790 800 810 820 830 840 850 C 0 12,209 12,624 13,040 13,457 13,874 14,293 14,713 15,133 15,554 15,975 16,397 16,820 17,243 17,667 18,091 18,516 18,941 19,366 19,792 20,218 20,644 21,071 21,497 21,924 22,350 22,776 23,203 23,629 24,055 24,480 24,905 25,330 25,755 26,179 26,602 27,025 27,447 27,869 28,289 28,710 29,129 29,548 29,965 30,382 30,798 31,213 31,628 32,041 32,453 32,865 33,275 33,685 34,093 34,501 34,908 35,313 0 1 12,250 12,665 13,081 13,498 13,916 14,335 14,755 15,175 15,596 16,017 16,439 16,862 17,285 17,709 18,134 18,558 18,983 19,409 19,835 20,261 20,687 21,113 21,540 21,966 22,393 22,819 23,245 23,671 24,097 24,523 24,948 25,373 25,797 26,221 26,644 27,067 27,489 27,911 28,332 28,752 29,171 29,589 30,007 30,424 30,840 31,255 31,669 32,082 32,495 32,906 33,316 33,726 34,134 34,542 34,948 35,354 1 2 12,291 12,707 13,123 13,540 13,958 14,377 14,797 15,217 15,638 16,059 16,482 16,904 17,328 17,752 18,176 18,601 19,026 19,451 19,877 20,303 20,730 21,156 21,582 22,009 22,435 22,862 23,288 23,714 24,140 24,565 24,990 25,415 25,840 26,263 26,687 27,109 27,531 27,953 28,374 28,794 29,213 29,631 30,049 30,466 30,881 31,296 31,710 32,124 32,536 32,947 33,357 33,767 34,175 34,582 34,989 35,394 2 3 12,333 12,748 13,165 13,582 14,000 14,419 14,839 15,259 15,680 16,102 16,524 16,947 17,370 17,794 18,218 18,643 19,068 19,494 19,920 20,346 20,772 21,199 21,625 22,052 22,478 22,904 23,331 23,757 24,182 24,608 25,033 25,458 25,882 26,306 26,729 27,152 27,574 27,995 28,416 28,835 29,255 29,673 30,090 30,507 30,923 31,338 31,752 32,165 32,577 32,988 33,398 33,808 34,216 34,623 35,029 35,435 3 4 12,374 12,790 13,206 13,624 14,042 14,461 14,881 15,301 15,722 16,144 16,566 16,989 17,413 17,837 18,261 18,686 19,111 19,537 19,962 20,389 20,815 21,241 21,668 22,094 22,521 22,947 23,373 23,799 24,225 24,650 25,075 25,500 25,924 26,348 26,771 27,194 27,616 28,037 28,458 28,877 29,297 29,715 30,132 30,549 30,964 31,379 31,793 32,206 32,618 33,029 33,439 33,848 34,257 34,664 35,070 35,475 4 5 12,416 12,831 13,248 13,665 14,084 14,503 14,923 15,343 15,764 16,186 16,608 17,031 17,455 17,879 18,303 18,728 19,154 19,579 20,005 20,431 20,857 21,284 21,710 22,137 22,563 22,990 23,416 23,842 24,267 24,693 25,118 25,543 25,967 26,390 26,814 27,236 27,658 28,079 28,500 28,919 29,338 29,757 30,174 30,590 31,006 31,421 31,834 32,247 32,659 33,070 33,480 33,889 34,297 34,704 35,110 35,516 5 6 12,457 12,873 13,290 13,707 14,126 14,545 14,965 15,385 15,806 16,228 16,651 17,074 17,497 17,921 18,346 18,771 19,196 19,622 20,048 20,474 20,900 21,326 21,753 22,179 22,606 23,032 23,458 23,884 24,310 24,735 25,160 25,585 26,009 26,433 26,856 27,278 27,700 28,121 28,542 28,961 29,380 29,798 30,216 30,632 31,047 31,462 31,876 32,289 32,700 33,111 33,521 33,930 34,338 34,745 35,151 35,556 6

THERMOCOUPLE

F.E.M. output of a K type thermocouple(Nikel/Cromium Vs.Copper/Nichel). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. cold junction 0 C 7 12,499 12,915 13,331 13,749 14,167 14,587 15,007 15,427 15,849 16,270 16,693 17,116 17,540 17,964 18,388 18,813 19,239 19,664 20,090 20,516 20,943 21,369 21,796 22,222 22,649 23,075 23,501 23,927 24,353 24,778 25,203 25,627 26,052 26,475 26,898 27,320 27,742 28,163 28,584 29,003 29,422 29,840 30,257 30,674 31,089 31,504 31,917 32,330 32,742 33,152 33,562 33,971 34,379 34,786 35,192 35,596 7 8 12,540 12,956 13,373 13,791 14,209 14,629 15,049 15,469 15,891 16,313 16,735 17,158 17,582 18,006 18,431 18,856 19,281 19,707 20,133 20,559 20,985 21,412 21,838 22,265 22,691 23,117 23,544 23,970 24,395 24,820 25,245 25,670 26,094 26,517 26,940 27,363 27,784 28,205 28,626 29,045 29,464 29,882 30,299 30,715 31,130 31,545 31,958 32,371 32,783 33,193 33,603 34,012 34,420 34,826 35,232 35,637 8 9 12,582 12,998 13,415 13,833 14,251 14,671 15,091 15,511 15,933 16,355 16,778 17,201 17,624 18,049 18,473 18,898 19,324 19,750 20,175 20,602 21,028 21,454 21,881 22,307 22,734 23,160 23,586 24,012 24,438 24,863 25,288 25,712 26,136 26,560 26,983 27,405 27,826 28,247 28,668 29,087 29,506 29,924 30,341 30,757 31,172 31,586 32,000 32,412 32,824 33,234 33,644 34,053 34,460 34,867 35,273 35,677 9 10 12,624 13,040 13,457 13,874 14,293 14,713 15,133 15,554 15,975 16,397 16,820 17,243 17,667 18,091 18,516 18,941 19,366 19,792 20,218 20,644 21,071 21,497 21,924 22,350 22,776 23,203 23,629 24,055 24,480 24,905 25,330 25,755 26,179 26,602 27,025 27,447 27,869 28,289 28,710 29,129 29,548 29,965 30,382 30,798 31,213 31,628 32,041 32,453 32,865 33,275 33,685 34,093 34,501 34,908 35,313 35,718 10 CABLE COLOR CODING IEC 584-3 CABLE COLOR CODING ANSI TEMPERATURE RANGE (-270 +1370 C)

LA TERMOTECNICA
C 850 860 870 880 890 900 910 920 930 940 950 960 970 980 990 1000 1010 1020 1030 1040 1050 1060 1070 1080 1090 1100 1110 1120 1130 1140 1150 1160 1170 1180 1190 1200 1210 1220 1230 1240 1250 1260 1270 C 0 35,313 35,718 36,121 36,524 36,925 37,326 37,725 38,124 38,522 38,918 39,314 39,708 40,101 40,494 40,885 41,276 41,665 42,053 42,440 42,826 43,211 43,595 43,978 44,359 44,740 45,119 45,497 45,873 46,249 46,623 46,995 47,367 47,737 48,105 48,473 48,838 49,202 49,565 49,926 50,286 50,644 51,000 51,355 0 1 35,354 35,758 36,162 36,564 36,965 37,366 37,765 38,164 38,561 38,958 39,353 39,747 40,141 40,533 40,924 41,315 41,704 42,092 42,479 42,865 43,250 43,633 44,016 44,397 44,778 45,157 45,534 45,911 46,286 46,660 47,033 47,404 47,774 48,142 48,509 48,875 49,239 49,601 49,962 50,322 50,680 51,036 51,391 1 2 35,394 35,798 36,202 36,604 37,006 37,406 37,805 38,204 38,601 38,997 39,393 39,787 40,180 40,572 40,963 41,354 41,743 42,131 42,518 42,903 43,288 43,672 44,054 44,435 44,816 45,194 45,572 45,948 46,324 46,697 47,070 47,441 47,811 48,179 48,546 48,911 49,275 49,637 49,998 50,358 50,715 51,071 51,426 2 3 35,435 35,839 36,242 36,644 37,046 37,446 37,845 38,243 38,641 39,037 39,432 39,826 40,219 40,611 41,002 41,393 41,781 42,169 42,556 42,942 43,327 43,710 44,092 44,473 44,853 45,232 45,610 45,986 46,361 46,735 47,107 47,478 47,848 48,216 48,582 48,948 49,311 49,674 50,034 50,393 50,751 51,107 51,461 3 4 35,475 35,879 36,282 36,685 37,086 37,486 37,885 38,283 38,680 39,076 39,471 39,866 40,259 40,651 41,042 41,431 41,820 42,208 42,595 42,980 43,365 43,748 44,130 44,512 44,891 45,270 45,647 46,024 46,398 46,772 47,144 47,515 47,884 48,252 48,619 48,984 49,348 49,710 50,070 50,429 50,787 51,142 51,497 4 5 35,516 35,920 36,323 36,725 37,126 37,526 37,925 38,323 38,720 39,116 39,511 39,905 40,298 40,690 41,081 41,470 41,859 42,247 42,633 43,019 43,403 43,787 44,169 44,550 44,929 45,308 45,685 46,061 46,436 46,809 47,181 47,552 47,921 48,289 48,656 49,021 49,384 49,746 50,106 50,465 50,822 51,178 51,532 5 6 35,556 35,960 36,363 36,765 37,166 37,566 37,965 38,363 38,760 39,155 39,550 39,944 40,337 40,729 41,120 41,509 41,898 42,286 42,672 43,057 43,442 43,825 44,207 44,588 44,967 45,346 45,723 46,099 46,473 46,847 47,218 47,589 47,958 48,326 48,692 49,057 49,420 49,782 50,142 50,501 50,858 51,213 51,567 6

THERMOCOUPLE

F.E.M. output of a K type thermocouple(Nikel/Cromium Vs.Copper/Nichel). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. cold junction 0 C 7 35,596 36,000 36,403 36,805 37,206 37,606 38,005 38,402 38,799 39,195 39,590 39,984 40,376 40,768 41,159 41,548 41,937 42,324 42,711 43,096 43,480 43,863 44,245 44,626 45,005 45,383 45,760 46,136 46,511 46,884 47,256 47,626 47,995 48,363 48,729 49,093 49,456 49,818 50,178 50,537 50,894 51,249 51,603 7 8 35,637 36,041 36,443 36,845 37,246 37,646 38,044 38,442 38,839 39,235 39,629 40,023 40,415 40,807 41,198 41,587 41,976 42,363 42,749 43,134 43,518 43,901 44,283 44,664 45,043 45,421 45,798 46,174 46,548 46,921 47,293 47,663 48,032 48,399 48,765 49,130 49,493 49,854 50,214 50,572 50,929 51,284 51,638 8 9 35,677 36,081 36,484 36,885 37,286 37,686 38,084 38,482 38,878 39,274 39,669 40,062 40,455 40,846 41,237 41,626 42,014 42,402 42,788 43,173 43,557 43,940 44,321 44,702 45,081 45,459 45,836 46,211 46,585 46,958 47,330 47,700 48,069 48,436 48,802 49,166 49,529 49,890 50,250 50,608 50,965 51,320 51,673 9 10 35,718 36,121 36,524 36,925 37,326 37,725 38,124 38,522 38,918 39,314 39,708 40,101 40,494 40,885 41,276 41,665 42,053 42,440 42,826 43,211 43,595 43,978 44,359 44,740 45,119 45,497 45,873 46,249 46,623 46,995 47,367 47,737 48,105 48,473 48,838 49,202 49,565 49,926 50,286 50,644 51,000 51,355 51,708 10 CABLE COLOR CODING IEC 584-3 CABLE COLOR CODING ANSI TEMPERATURE RANGE (-270 +1370 C)

LA TERMOTECNICA
C 1270 1280 1290 1300 1310 1320 1330 1340 1350 1360 1370 C 0 51,355 51,708 52,060 52,410 52,759 53,106 53,451 53,795 54,138 54,479 54,819 0 1 51,391 51,744 52,095 52,445 52,794 53,140 53,486 53,830 54,172 54,513 54,852 1 2 51,426 51,779 52,130 52,480 52,828 53,175 53,520 53,864 54,206 54,547 54,886 2 3 51,461 51,814 52,165 52,515 52,863 53,210 53,555 53,898 54,240 54,581 54,920 3 4 51,497 51,849 52,200 52,550 52,898 53,244 53,589 53,932 54,274 54,615 54,954 4 5 51,532 51,885 52,235 52,585 52,932 53,279 53,623 53,967 54,308 54,649 54,988 5 6 51,567 51,920 52,270 52,620 52,967 53,313 53,658 54,001 54,343 54,683 55,022 6

THERMOCOUPLE

F.E.M. output of a K type thermocouple(Nikel/Cromium Vs.Copper/Nichel). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. cold junction 0 C 7 51,603 51,955 52,305 52,654 53,002 53,348 53,692 54,035 54,377 54,717 55,056 7 8 51,638 51,990 52,340 52,689 53,037 53,382 53,727 54,069 54,411 54,751 55,089 8 9 51,673 52,025 52,375 52,724 53,071 53,417 53,761 54,104 54,445 54,785 55,123 9 10 51,708 52,060 52,410 52,759 53,106 53,451 53,795 54,138 54,479 54,819 55,157 10 CABLE COLOR CODING ANSI TEMPERATURE RANGE (-270 +1370 C)

LA TERMOTECNICA
F.E.M. output of a J type thermocouple(Iron/Copper Vs. lron). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. C -200 -190 -180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 C C 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 C 0 -7,890 -7,659 -7,403 -7,123 -6,821 -6,500 -6,159 -5,801 -5,426 -5,037 -4,633 -4,215 -3,786 -3,344 -2,893 -2,431 -1,961 -1,482 -0,995 -0,501 0,000 0 0 0,000 0,507 1,019 1,537 2,059 2,585 3,116 3,650 4,187 4,726 5,269 5,814 6,360 6,909 7,459 8,010 8,562 9,115 9,669 10,224 10,779 11,334 11,889 12,445 13,000 13,555 14,110 14,665 15,219 15,773 16,327 16,881 17,434 0 -7,683 -7,429 -7,152 -6,853 -6,533 -6,194 -5,838 -5,465 -5,076 -4,674 -4,257 -3,829 -3,389 -2,938 -2,478 -2,008 -1,530 -1,044 -0,550 -0,050 -1 1 0,050 0,558 1,071 1,589 2,111 2,638 3,169 3,703 4,240 4,781 5,323 5,868 6,415 6,964 7,514 8,065 8,618 9,171 9,725 10,279 10,834 11,389 11,945 12,500 13,056 13,611 14,166 14,720 15,275 15,829 16,383 16,936 17,489 1 -7,707 -7,456 -7,181 -6,883 -6,566 -6,229 -5,874 -5,503 -5,116 -4,714 -4,300 -3,872 -3,434 -2,984 -2,524 -2,055 -1,578 -1,093 -0,600 -0,101 -2 2 0,101 0,609 1,122 1,641 2,164 2,691 3,222 3,757 4,294 4,835 5,378 5,923 6,470 7,019 7,569 8,120 8,673 9,226 9,780 10,335 10,890 11,445 12,000 12,556 13,111 13,666 14,221 14,776 15,330 15,884 16,438 16,991 17,544 2 -7,731 -7,482 -7,209 -6,914 -6,598 -6,263 -5,910 -5,541 -5,155 -4,755 -4,342 -3,916 -3,478 -3,029 -2,571 -2,103 -1,626 -1,142 -0,650 -0,151 -3 3 0,151 0,660 1,174 1,693 2,216 2,744 3,275 3,810 4,348 4,889 5,432 5,977 6,525 7,074 7,624 8,175 8,728 9,282 9,836 10,390 10,945 11,501 12,056 12,611 13,167 13,722 14,277 14,831 15,386 15,940 16,493 17,046 17,599 3 -7,755 -7,508 -7,237 -6,944 -6,631 -6,298 -5,946 -5,578 -5,194 -4,796 -4,384 -3,959 -3,522 -3,075 -2,617 -2,150 -1,674 -1,190 -0,699 -0,201 -4 4 0,202 0,711 1,226 1,745 2,269 2,797 3,329 3,864 4,402 4,943 5,487 6,032 6,579 7,129 7,679 8,231 8,783 9,337 9,891 10,446 11,001 11,556 12,111 12,667 13,222 13,777 14,332 14,887 15,441 15,995 16,549 17,102 17,655 4 -7,778 -7,534 -7,265 -6,975 -6,663 -6,332 -5,982 -5,616 -5,233 -4,836 -4,425 -4,002 -3,566 -3,120 -2,663 -2,197 -1,722 -1,239 -0,749 -0,251 -5 5 0,253 0,762 1,277 1,797 2,322 2,850 3,382 3,918 4,456 4,997 5,541 6,087 6,634 7,184 7,734 8,286 8,839 9,392 9,947 10,501 11,056 11,612 12,167 12,722 13,278 13,833 14,388 14,942 15,496 16,050 16,604 17,157 17,710 5 -7,801 -7,559 -7,293 -7,005 -6,695 -6,366 -6,018 -5,653 -5,272 -4,877 -4,467 -4,045 -3,610 -3,165 -2,709 -2,244 -1,770 -1,288 -0,798 -0,301 -6 6 0,303 0,814 1,329 1,849 2,374 2,903 3,436 3,971 4,510 5,052 5,595 6,141 6,689 7,239 7,789 8,341 8,894 9,448 10,002 10,557 11,112 11,667 12,222 12,778 13,333 13,888 14,443 14,998 15,552 16,106 16,659 17,212 17,765 6 -1 -2 -3 -4 -5 -6

THERMOCOUPLE
cold junction 0 C -7 -7,824 -7,585 -7,321 -7,035 -6,727 -6,400 -6,054 -5,690 -5,311 -4,917 -4,509 -4,088 -3,654 -3,210 -2,755 -2,291 -1,818 -1,336 -0,847 -0,351 -7 7 0,354 0,865 1,381 1,902 2,427 2,956 3,489 4,025 4,564 5,106 5,650 6,196 6,744 7,294 7,844 8,396 8,949 9,503 10,057 10,612 11,167 11,723 12,278 12,833 13,389 13,944 14,499 15,053 15,607 16,161 16,715 17,268 17,820 7 -8 -7,846 -7,610 -7,348 -7,064 -6,759 -6,433 -6,089 -5,727 -5,350 -4,957 -4,550 -4,130 -3,698 -3,255 -2,801 -2,338 -1,865 -1,385 -0,896 -0,401 -8 8 0,405 0,916 1,433 1,954 2,480 3,009 3,543 4,079 4,618 5,160 5,705 6,251 6,799 7,349 7,900 8,452 9,005 9,559 10,113 10,668 11,223 11,778 12,334 12,889 13,444 13,999 14,554 15,109 15,663 16,216 16,770 17,323 17,876 8 -9 -7,868 -7,634 -7,376 -7,094 -6,790 -6,467 -6,124 -5,764 -5,388 -4,997 -4,591 -4,173 -3,742 -3,300 -2,847 -2,385 -1,913 -1,433 -0,946 -0,451 -9 9 0,456 0,968 1,485 2,006 2,532 3,062 3,596 4,133 4,672 5,215 5,759 6,306 6,854 7,404 7,955 8,507 9,060 9,614 10,168 10,723 11,278 11,834 12,389 12,944 13,500 14,055 14,609 15,164 15,718 16,272 16,825 17,378 17,931 9 -10 -7,890 -7,659 -7,403 -7,123 -6,821 -6,500 -6,159 -5,801 -5,426 -5,037 -4,633 -4,215 -3,786 -3,344 -2,893 -2,431 -1,961 -1,482 -0,995 -0,501 -10 10 0,507 1,019 1,537 2,059 2,585 3,116 3,650 4,187 4,726 5,269 5,814 6,360 6,909 7,459 8,010 8,562 9,115 9,669 10,224 10,779 11,334 11,889 12,445 13,000 13,555 14,110 14,665 15,219 15,773 16,327 16,881 17,434 17,986 10

TEMPERATURE RANGE (-200 +760 C) CABLE COLOR CODING ANSI

CABLE COLOR CODING IEC 584-3

LA TERMOTECNICA
F.E.M. output of a J type thermocouple(Iron/Copper Vs. lron). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. C 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600 610 620 630 640 650 660 670 680 690 700 710 720 730 740 750 760 C 0 17,986 18,538 19,090 19,642 20,194 20,745 21,297 21,848 22,400 22,952 23,504 24,057 24,610 25,164 25,720 26,276 26,834 27,393 27,953 28,516 29,080 29,647 30,216 30,788 31,362 31,939 32,519 33,102 33,689 34,279 34,873 35,470 36,071 36,675 37,284 37,896 38,512 39,132 39,755 40,382 41,012 41,645 42,281 42,919 0 1 2 3 4 5 6 1 18,041 18,594 19,146 19,697 20,249 20,800 21,352 21,903 22,455 23,007 23,559 24,112 24,665 25,220 25,775 26,332 26,889 27,449 28,010 28,572 29,137 29,704 30,273 30,845 31,419 31,997 32,577 33,161 33,748 34,338 34,932 35,530 36,131 36,736 37,345 37,958 38,574 39,194 39,818 40,445 41,075 41,708 42,344 2 18,097 18,649 19,201 19,753 20,304 20,855 21,407 21,958 22,510 23,062 23,614 24,167 24,721 25,275 25,831 26,387 26,945 27,505 28,066 28,629 29,194 29,761 30,330 30,902 31,477 32,055 32,636 33,219 33,807 34,397 34,992 35,590 36,191 36,797 37,406 38,019 38,636 39,256 39,880 40,508 41,138 41,772 42,408 3 18,152 18,704 19,256 19,808 20,359 20,911 21,462 22,014 22,565 23,117 23,670 24,223 24,776 25,331 25,886 26,443 27,001 27,561 28,122 28,685 29,250 29,818 30,387 30,960 31,535 32,113 32,694 33,278 33,866 34,457 35,051 35,650 36,252 36,858 37,467 38,081 38,698 39,318 39,943 40,570 41,201 41,835 42,472 4 18,207 18,759 19,311 19,863 20,414 20,966 21,517 22,069 22,620 23,172 23,725 24,278 24,832 25,386 25,942 26,499 27,057 27,617 28,178 28,741 29,307 29,874 30,444 31,017 31,592 32,171 32,752 33,337 33,925 34,516 35,111 35,710 36,312 36,918 37,528 38,142 38,760 39,381 40,005 40,633 41,265 41,899 42,536 5 18,262 18,814 19,366 19,918 20,469 21,021 21,572 22,124 22,676 23,228 23,780 24,333 24,887 25,442 25,998 26,555 27,113 27,673 28,234 28,798 29,363 29,931 30,502 31,074 31,650 32,229 32,810 33,395 33,984 34,575 35,171 35,770 36,373 36,979 37,590 38,204 38,822 39,443 40,068 40,696 41,328 41,962 42,599 6 18,318 18,870 19,422 19,973 20,525 21,076 21,627 22,179 22,731 23,283 23,835 24,389 24,943 25,497 26,053 26,610 27,169 27,729 28,291 28,854 29,420 29,988 30,559 31,132 31,708 32,287 32,869 33,454 34,043 34,635 35,230 35,830 36,433 37,040 37,651 38,265 38,884 39,505 40,131 40,759 41,391 42,026 42,663

THERMOCOUPLE
cold junction 0 C 7 18,373 18,925 19,477 20,028 20,580 21,131 21,683 22,234 22,786 23,338 23,891 24,444 24,998 25,553 26,109 26,666 27,225 27,785 28,347 28,911 29,477 30,045 30,616 31,189 31,766 32,345 32,927 33,513 34,102 34,694 35,290 35,890 36,494 37,101 37,712 38,327 38,946 39,568 40,193 40,822 41,455 42,090 42,727 7 8 18,428 18,980 19,532 20,083 20,635 21,186 21,738 22,289 22,841 23,393 23,946 24,499 25,053 25,608 26,165 26,722 27,281 27,841 28,403 28,967 29,534 30,102 30,673 31,247 31,823 32,403 32,985 33,571 34,161 34,754 35,350 35,950 36,554 37,162 37,773 38,389 39,008 39,630 40,256 40,886 41,518 42,153 42,791 8 9 18,483 19,035 19,587 20,139 20,690 21,241 21,793 22,345 22,896 23,449 24,001 24,555 25,109 25,664 26,220 26,778 27,337 27,897 28,460 29,024 29,590 30,159 30,730 31,304 31,881 32,461 33,044 33,630 34,220 34,813 35,410 36,010 36,615 37,223 37,835 38,450 39,070 39,693 40,319 40,949 41,581 42,217 42,855 9 10 18,538 19,090 19,642 20,194 20,745 21,297 21,848 22,400 22,952 23,504 24,057 24,610 25,164 25,720 26,276 26,834 27,393 27,953 28,516 29,080 29,647 30,216 30,788 31,362 31,939 32,519 33,102 33,689 34,279 34,873 35,470 36,071 36,675 37,284 37,896 38,512 39,132 39,755 40,382 41,012 41,645 42,281 42,919 10

TEMPERATURE RANGE (-200 +760 C) CABLE COLOR CODING ANSI

CABLE COLOR CODING IEC 584-3

LA TERMOTECNICA
F.E.M. output of a T type thermocouple(Copper Vs. Copper/Nichel). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. C -270 -260 -250 -240 -230 -220 -210 -200 -190 -180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 C C 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 C 0 -6,258 -6,232 -6,180 -6,105 -6,007 -5,888 -5,753 -5,603 -5,439 -5,261 -5,070 -4,865 -4,648 -4,419 -4,177 -3,923 -3,657 -3,379 -3,089 -2,788 -2,476 -2,153 -1,819 -1,475 -1,121 -0,757 -0,383 0,000 0 0 0,000 0,391 0,790 1,196 1,612 2,036 2,468 2,909 3,358 3,814 4,279 4,750 5,228 5,714 6,206 6,704 7,209 7,720 8,237 8,759 9,288 9,822 10,362 10,907 11,458 12,013 0 -6,236 -6,187 -6,114 -6,017 -5,901 -5,767 -5,619 -5,456 -5,279 -5,089 -4,886 -4,671 -4,443 -4,202 -3,949 -3,684 -3,407 -3,118 -2,818 -2,507 -2,186 -1,853 -1,510 -1,157 -0,794 -0,421 -0,039 -1 1 0,039 0,431 0,830 1,238 1,654 2,079 2,512 2,953 3,403 3,860 4,325 4,798 5,277 5,763 6,255 6,754 7,260 7,771 8,289 8,812 9,341 9,876 10,417 10,962 11,513 12,069 1 -6,239 -6,193 -6,122 -6,028 -5,914 -5,782 -5,634 -5,473 -5,297 -5,109 -4,907 -4,693 -4,466 -4,226 -3,975 -3,711 -3,435 -3,148 -2,849 -2,539 -2,218 -1,887 -1,545 -1,192 -0,830 -0,459 -0,077 -2 2 0,078 0,470 0,870 1,279 1,696 2,122 2,556 2,998 3,448 3,907 4,372 4,845 5,325 5,812 6,305 6,805 7,310 7,823 8,341 8,865 9,395 9,930 10,471 11,017 11,569 12,125 2 -6,242 -6,198 -6,130 -6,038 -5,926 -5,795 -5,650 -5,489 -5,316 -5,128 -4,928 -4,715 -4,489 -4,251 -4,000 -3,738 -3,463 -3,177 -2,879 -2,571 -2,251 -1,920 -1,579 -1,228 -0,867 -0,496 -0,116 -3 3 0,117 0,510 0,911 1,320 1,738 2,165 2,600 3,043 3,494 3,953 4,419 4,893 5,373 5,861 6,355 6,855 7,361 7,874 8,393 8,917 9,448 9,984 10,525 11,072 11,624 12,181 3 -6,245 -6,204 -6,138 -6,049 -5,938 -5,809 -5,665 -5,506 -5,334 -5,148 -4,949 -4,737 -4,512 -4,275 -4,026 -3,765 -3,491 -3,206 -2,910 -2,602 -2,283 -1,954 -1,614 -1,264 -0,904 -0,534 -0,154 -4 4 0,156 0,549 0,951 1,362 1,780 2,208 2,643 3,087 3,539 3,999 4,466 4,941 5,422 5,910 6,404 6,905 7,412 7,926 8,445 8,970 9,501 10,038 10,580 11,127 11,680 12,237 4 -6,248 -6,209 -6,146 -6,059 -5,950 -5,823 -5,680 -5,523 -5,351 -5,167 -4,969 -4,759 -4,535 -4,300 -4,052 -3,791 -3,519 -3,235 -2,940 -2,633 -2,316 -1,987 -1,648 -1,299 -0,940 -0,571 -0,193 -5 5 0,195 0,589 0,992 1,403 1,823 2,251 2,687 3,132 3,585 4,046 4,513 4,988 5,470 5,959 6,454 6,956 7,463 7,977 8,497 9,023 9,555 10,092 10,634 11,182 11,735 12,293 5 -6,251 -6,214 -6,153 -6,068 -5,962 -5,836 -5,695 -5,539 -5,369 -5,186 -4,989 -4,780 -4,558 -4,324 -4,077 -3,818 -3,547 -3,264 -2,970 -2,664 -2,348 -2,021 -1,683 -1,335 -0,976 -0,608 -0,231 -6 6 0,234 0,629 1,033 1,445 1,865 2,294 2,732 3,177 3,631 4,092 4,561 5,036 5,519 6,008 6,504 7,006 7,515 8,029 8,550 9,076 9,608 10,146 10,689 11,237 11,791 12,349 6 -1 -2 -3 -4 -5 -6

THERMOCOUPLE
cold junction 0 C -7 -6,253 -6,219 -6,160 -6,078 -5,973 -5,850 -5,710 -5,555 -5,387 -5,205 -5,010 -4,802 -4,581 -4,348 -4,102 -3,844 -3,574 -3,293 -3,000 -2,695 -2,380 -2,054 -1,717 -1,370 -1,013 -0,646 -0,269 -7 7 0,273 0,669 1,074 1,486 1,908 2,338 2,776 3,222 3,677 4,138 4,608 5,084 5,567 6,057 6,554 7,057 7,566 8,081 8,602 9,129 9,662 10,200 10,743 11,292 11,846 12,405 7 -8 -6,255 -6,223 -6,167 -6,087 -5,985 -5,863 -5,724 -5,571 -5,404 -5,224 -5,030 -4,823 -4,604 -4,372 -4,127 -3,871 -3,602 -3,322 -3,030 -2,726 -2,412 -2,087 -1,751 -1,405 -1,049 -0,683 -0,307 -8 8 0,312 0,709 1,114 1,528 1,950 2,381 2,820 3,267 3,722 4,185 4,655 5,132 5,616 6,107 6,604 7,107 7,617 8,133 8,654 9,182 9,715 10,254 10,798 11,347 11,902 12,461 8 -9 -6,256 -6,228 -6,174 -6,096 -5,996 -5,876 -5,739 -5,587 -5,421 -5,242 -5,050 -4,844 -4,626 -4,395 -4,152 -3,897 -3,629 -3,350 -3,059 -2,757 -2,444 -2,120 -1,785 -1,440 -1,085 -0,720 -0,345 -9 9 0,352 0,749 1,155 1,570 1,993 2,425 2,864 3,312 3,768 4,232 4,702 5,180 5,665 6,156 6,654 7,158 7,668 8,185 8,707 9,235 9,769 10,308 10,853 11,403 11,958 12,518 9 -10 -6,258 -6,232 -6,180 -6,105 -6,007 -5,888 -5,753 -5,603 -5,439 -5,261 -5,070 -4,865 -4,648 -4,419 -4,177 -3,923 -3,657 -3,379 -3,089 -2,788 -2,476 -2,153 -1,819 -1,475 -1,121 -0,757 -0,383 -10 10 0,391 0,790 1,196 1,612 2,036 2,468 2,909 3,358 3,814 4,279 4,750 5,228 5,714 6,206 6,704 7,209 7,720 8,237 8,759 9,288 9,822 10,362 10,907 11,458 12,013 12,574 10

TEMPERATURE RANGE (-270 +400 C) CABLE COLOR CODING ANSI

CABLE COLOR CODING IEC 584-3

LA TERMOTECNICA
F.E.M. output of a T type thermocouple(Copper Vs. Copper/Nichel). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. C 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 C 0 12,013 12,574 13,139 13,709 14,283 14,862 15,445 16,032 16,624 17,219 17,819 18,422 19,030 19,641 20,255 20,872 0 1 2 3 4 5 6 1 12,069 12,630 13,196 13,766 14,341 14,920 15,503 16,091 16,683 17,279 17,879 18,483 19,091 19,702 20,317 2 12,125 12,687 13,253 13,823 14,399 14,978 15,562 16,150 16,742 17,339 17,939 18,543 19,152 19,763 20,378 3 12,181 12,743 13,310 13,881 14,456 15,036 15,621 16,209 16,802 17,399 17,999 18,604 19,213 19,825 20,440 4 12,237 12,799 13,366 13,938 14,514 15,095 15,679 16,268 16,861 17,458 18,060 18,665 19,274 19,886 20,502 5 12,293 12,856 13,423 13,995 14,572 15,153 15,738 16,327 16,921 17,518 18,120 18,725 19,335 19,947 20,563 6 12,349 12,912 13,480 14,053 14,630 15,211 15,797 16,387 16,980 17,578 18,180 18,786 19,396 20,009 20,625

THERMOCOUPLE
cold junction 0 C 7 12,405 12,969 13,537 14,110 14,688 15,270 15,856 16,446 17,040 17,638 18,241 18,847 19,457 20,070 20,687 7 8 12,461 13,026 13,595 14,168 14,746 15,328 15,914 16,505 17,100 17,698 18,301 18,908 19,518 20,132 20,748 8 9 12,518 13,082 13,652 14,226 14,804 15,386 15,973 16,564 17,159 17,759 18,362 18,969 19,579 20,193 20,810 9 10 12,574 13,139 13,709 14,283 14,862 15,445 16,032 16,624 17,219 17,819 18,422 19,030 19,641 20,255 20,872 10

TEMPERATURE RANGE (-270 +400 C) CABLE COLOR CODING ANSI

LA TERMOTECNICA
F.E.M. output of a N type thermocouple(Nicrosil Vs. Nisill). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. C -270 -260 -250 -240 -230 -220 -210 -200 -190 -180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 C C 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 C 0 -4,345 -4,336 -4,313 -4,277 -4,226 -4,162 -4,083 -3,990 -3,884 -3,766 -3,634 -3,491 -3,336 -3,171 -2,994 -2,808 -2,612 -2,407 -2,193 -1,972 -1,744 -1,509 -1,269 -1,023 -0,772 -0,518 -0,260 0,000 0 0 0,000 0,261 0,525 0,793 1,065 1,340 1,619 1,902 2,189 2,480 2,774 3,072 3,374 3,680 3,989 4,302 4,618 4,937 5,259 5,585 5,913 6,245 6,579 6,916 7,255 7,597 0 -4,337 -4,316 -4,281 -4,232 -4,169 -4,091 -4,000 -3,896 -3,778 -3,648 -3,506 -3,352 -3,188 -3,012 -2,827 -2,632 -2,428 -2,215 -1,995 -1,767 -1,533 -1,293 -1,048 -0,798 -0,544 -0,286 -0,026 -1 1 0,026 0,287 0,552 0,820 1,092 1,368 1,647 1,930 2,218 2,509 2,804 3,102 3,405 3,711 4,020 4,333 4,650 4,969 5,292 5,618 5,946 6,278 6,612 6,949 7,289 7,631 1 -4,339 -4,319 -4,285 -4,238 -4,176 -4,100 -4,010 -3,907 -3,790 -3,662 -3,521 -3,368 -3,205 -3,030 -2,846 -2,652 -2,448 -2,237 -2,017 -1,790 -1,557 -1,317 -1,072 -0,823 -0,569 -0,312 -0,052 -2 2 0,052 0,313 0,578 0,847 1,119 1,395 1,675 1,959 2,247 2,538 2,833 3,133 3,435 3,742 4,051 4,365 4,681 5,001 5,324 5,650 5,979 6,311 6,646 6,983 7,323 7,666 2 -4,340 -4,321 -4,289 -4,243 -4,183 -4,108 -4,020 -3,918 -3,803 -3,675 -3,535 -3,384 -3,221 -3,048 -2,865 -2,672 -2,469 -2,258 -2,039 -1,813 -1,580 -1,341 -1,097 -0,848 -0,595 -0,338 -0,078 -3 3 0,078 0,340 0,605 0,874 1,147 1,423 1,703 1,988 2,276 2,568 2,863 3,163 3,466 3,772 4,083 4,396 4,713 5,033 5,357 5,683 6,013 6,345 6,680 7,017 7,357 7,700 3 -4,341 -4,324 -4,293 -4,248 -4,189 -4,116 -4,029 -3,928 -3,815 -3,688 -3,550 -3,400 -3,238 -3,066 -2,883 -2,691 -2,490 -2,280 -2,062 -1,836 -1,604 -1,366 -1,122 -0,873 -0,620 -0,364 -0,104 -4 4 0,104 0,366 0,632 0,901 1,174 1,451 1,732 2,016 2,305 2,597 2,893 3,193 3,496 3,803 4,114 4,428 4,745 5,066 5,389 5,716 6,046 6,378 6,713 7,051 7,392 7,734 4 -4,342 -4,326 -4,297 -4,254 -4,196 -4,124 -4,038 -3,939 -3,827 -3,702 -3,564 -3,415 -3,255 -3,084 -2,902 -2,711 -2,510 -2,301 -2,084 -1,859 -1,627 -1,390 -1,146 -0,898 -0,646 -0,390 -0,131 -5 5 0,130 0,393 0,659 0,928 1,202 1,479 1,760 2,045 2,334 2,626 2,923 3,223 3,527 3,834 4,145 4,459 4,777 5,098 5,422 5,749 6,079 6,411 6,747 7,085 7,426 7,769 5 -4,343 -4,328 -4,300 -4,258 -4,202 -4,132 -4,048 -3,950 -3,838 -3,715 -3,578 -3,431 -3,271 -3,101 -2,921 -2,730 -2,531 -2,322 -2,106 -1,882 -1,651 -1,414 -1,171 -0,923 -0,671 -0,415 -0,157 -6 6 0,156 0,419 0,685 0,955 1,229 1,507 1,788 2,074 2,363 2,656 2,953 3,253 3,557 3,865 4,176 4,491 4,809 5,130 5,454 5,782 6,112 6,445 6,781 7,119 7,460 7,803 6 -1 -2 -3 -4 -5 -6

THERMOCOUPLE
cold junction 0 C -7 -4,344 -4,330 -4,304 -4,263 -4,209 -4,140 -4,057 -3,960 -3,850 -3,728 -3,593 -3,446 -3,288 -3,119 -2,939 -2,750 -2,551 -2,344 -2,128 -1,905 -1,674 -1,438 -1,195 -0,948 -0,696 -0,441 -0,183 -7 7 0,182 0,446 0,712 0,983 1,257 1,535 1,817 2,102 2,392 2,685 2,983 3,283 3,588 3,896 4,208 4,523 4,841 5,162 5,487 5,815 6,145 6,478 6,814 7,153 7,494 7,838 7 -8 -4,344 -4,332 -4,307 -4,268 -4,215 -4,147 -4,066 -3,970 -3,862 -3,740 -3,607 -3,461 -3,304 -3,136 -2,958 -2,769 -2,571 -2,365 -2,150 -1,927 -1,698 -1,462 -1,220 -0,973 -0,722 -0,467 -0,209 -8 8 0,208 0,472 0,739 1,010 1,284 1,563 1,845 2,131 2,421 2,715 3,012 3,314 3,619 3,927 4,239 4,554 4,873 5,195 5,520 5,847 6,178 6,512 6,848 7,187 7,528 7,872 8 -9 -4,345 -4,334 -4,310 -4,273 -4,221 -4,154 -4,074 -3,980 -3,873 -3,753 -3,621 -3,476 -3,320 -3,153 -2,976 -2,789 -2,592 -2,386 -2,172 -1,950 -1,721 -1,485 -1,244 -0,998 -0,747 -0,492 -0,234 -9 9 0,235 0,499 0,766 1,037 1,312 1,591 1,873 2,160 2,450 2,744 3,042 3,344 3,649 3,958 4,270 4,586 4,905 5,227 5,552 5,880 6,211 6,545 6,882 7,221 7,563 7,907 9 -10 -4,345 -4,336 -4,313 -4,277 -4,226 -4,162 -4,083 -3,990 -3,884 -3,766 -3,634 -3,491 -3,336 -3,171 -2,994 -2,808 -2,612 -2,407 -2,193 -1,972 -1,744 -1,509 -1,269 -1,023 -0,772 -0,518 -0,260 -10 10 0,261 0,525 0,793 1,065 1,340 1,619 1,902 2,189 2,480 2,774 3,072 3,374 3,680 3,989 4,302 4,618 4,937 5,259 5,585 5,913 6,245 6,579 6,916 7,255 7,597 7,941 10

TEMPERATURE RANGE (-270 +1300 C) CABLE COLOR CODING ANSI

CABLE COLOR CODING IEC 584-3

LA TERMOTECNICA
F.E.M. output of a N type thermocouple(Nicrosil Vs. Nisill). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. C 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600 610 620 630 640 650 660 670 680 690 700 710 720 730 740 750 760 770 780 790 800 C 0 7,597 7,941 8,288 8,637 8,988 9,341 9,696 10,054 10,413 10,774 11,136 11,501 11,867 12,234 12,603 12,974 13,346 13,719 14,094 14,469 14,846 15,225 15,604 15,984 16,366 16,748 17,131 17,515 17,900 18,286 18,672 19,059 19,447 19,835 20,224 20,613 21,003 21,393 21,784 22,175 22,566 22,958 23,350 23,742 24,134 24,527 24,919 25,312 25,705 26,098 26,491 26,883 27,276 27,669 28,062 28,455 0 1 7,631 7,976 8,323 8,672 9,023 9,377 9,732 10,089 10,449 10,810 11,173 11,537 11,903 12,271 12,640 13,011 13,383 13,756 14,131 14,507 14,884 15,262 15,642 16,022 16,404 16,786 17,169 17,554 17,938 18,324 18,711 19,098 19,485 19,874 20,263 20,652 21,042 21,432 21,823 22,214 22,605 22,997 23,389 23,781 24,173 24,566 24,959 25,351 25,744 26,137 26,530 26,923 27,316 27,708 28,101 28,494 1 2 7,666 8,010 8,358 8,707 9,058 9,412 9,768 10,125 10,485 10,846 11,209 11,574 11,940 12,308 12,677 13,048 13,420 13,794 14,169 14,545 14,922 15,300 15,680 16,060 16,442 16,824 17,208 17,592 17,977 18,363 18,749 19,136 19,524 19,913 20,302 20,691 21,081 21,471 21,862 22,253 22,644 23,036 23,428 23,820 24,213 24,605 24,998 25,391 25,783 26,176 26,569 26,962 27,355 27,748 28,140 28,533 2 3 7,700 8,045 8,392 8,742 9,094 9,448 9,803 10,161 10,521 10,882 11,245 11,610 11,977 12,345 12,714 13,085 13,457 13,831 14,206 14,582 14,960 15,338 15,718 16,099 16,480 16,863 17,246 17,630 18,016 18,401 18,788 19,175 19,563 19,952 20,341 20,730 21,120 21,510 21,901 22,292 22,684 23,075 23,467 23,860 24,252 24,644 25,037 25,430 25,823 26,216 26,608 27,001 27,394 27,787 28,180 28,572 3 4 7,734 8,080 8,427 8,777 9,129 9,483 9,839 10,197 10,557 10,918 11,282 11,647 12,013 12,382 12,751 13,122 13,495 13,869 14,244 14,620 14,998 15,376 15,756 16,137 16,518 16,901 17,285 17,669 18,054 18,440 18,827 19,214 19,602 19,990 20,379 20,769 21,159 21,549 21,940 22,331 22,723 23,115 23,507 23,899 24,291 24,684 25,076 25,469 25,862 26,255 26,648 27,041 27,433 27,826 28,219 28,612 4 5 7,769 8,114 8,462 8,812 9,164 9,519 9,875 10,233 10,593 10,955 11,318 11,683 12,050 12,418 12,788 13,159 13,532 13,906 14,281 14,658 15,035 15,414 15,794 16,175 16,557 16,939 17,323 17,707 18,093 18,479 18,865 19,253 19,641 20,029 20,418 20,808 21,198 21,588 21,979 22,370 22,762 23,154 23,546 23,938 24,330 24,723 25,116 25,508 25,901 26,294 26,687 27,080 27,473 27,866 28,258 28,651 5 6 7,803 8,149 8,497 8,847 9,200 9,554 9,910 10,269 10,629 10,991 11,355 11,720 12,087 12,455 12,825 13,197 13,569 13,944 14,319 14,695 15,073 15,452 15,832 16,213 16,595 16,978 17,361 17,746 18,131 18,517 18,904 19,292 19,680 20,068 20,457 20,847 21,237 21,628 22,018 22,410 22,801 23,193 23,585 23,977 24,370 24,762 25,155 25,548 25,941 26,333 26,726 27,119 27,512 27,905 28,297 28,690 6

THERMOCOUPLE
cold junction 0 C 7 7,838 8,184 8,532 8,882 9,235 9,590 9,946 10,305 10,665 11,027 11,391 11,757 12,124 12,492 12,862 13,234 13,607 13,981 14,356 14,733 15,111 15,490 15,870 16,251 16,633 17,016 17,400 17,784 18,170 18,556 18,943 19,330 19,718 20,107 20,496 20,886 21,276 21,667 22,058 22,449 22,840 23,232 23,624 24,016 24,409 24,801 25,194 25,587 25,980 26,373 26,766 27,158 27,551 27,944 28,337 28,729 7 8 7,872 8,218 8,567 8,918 9,270 9,625 9,982 10,341 10,701 11,064 11,428 11,793 12,160 12,529 12,899 13,271 13,644 14,019 14,394 14,771 15,149 15,528 15,908 16,289 16,671 17,054 17,438 17,823 18,208 18,595 18,982 19,369 19,757 20,146 20,535 20,925 21,315 21,706 22,097 22,488 22,879 23,271 23,663 24,056 24,448 24,841 25,233 25,626 26,019 26,412 26,805 27,198 27,591 27,983 28,376 28,769 8 9 7,907 8,253 8,602 8,953 9,306 9,661 10,018 10,377 10,737 11,100 11,464 11,830 12,197 12,566 12,937 13,308 13,682 14,056 14,432 14,809 15,187 15,566 15,946 16,327 16,710 17,093 17,477 17,861 18,247 18,633 19,020 19,408 19,796 20,185 20,574 20,964 21,354 21,745 22,136 22,527 22,919 23,311 23,703 24,095 24,487 24,880 25,273 25,666 26,058 26,451 26,844 27,237 27,630 28,023 28,415 28,808 9 10 7,941 8,288 8,637 8,988 9,341 9,696 10,054 10,413 10,774 11,136 11,501 11,867 12,234 12,603 12,974 13,346 13,719 14,094 14,469 14,846 15,225 15,604 15,984 16,366 16,748 17,131 17,515 17,900 18,286 18,672 19,059 19,447 19,835 20,224 20,613 21,003 21,393 21,784 22,175 22,566 22,958 23,350 23,742 24,134 24,527 24,919 25,312 25,705 26,098 26,491 26,883 27,276 27,669 28,062 28,455 28,847 10

TEMPERATURE RANGE (-270 +1300 C) CABLE COLOR CODING ANSI

CABLE COLOR CODING IEC 584-3

LA TERMOTECNICA
F.E.M. output of a N type thermocouple(Nicrosil Vs. Nisill). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. C 800 810 820 830 840 850 860 870 880 890 900 910 920 930 940 950 960 970 980 990 1000 1010 1020 1030 1040 1050 1060 1070 1080 1090 1100 1110 1120 1130 1140 1150 1160 1170 1180 1190 1200 1210 1220 1230 1240 1250 1260 1270 1280 1290 1300 C 0 28,455 28,847 29,239 29,632 30,024 30,416 30,807 31,199 31,590 31,981 32,371 32,761 33,151 33,541 33,930 34,319 34,707 35,095 35,482 35,869 36,256 36,641 37,027 37,411 37,795 38,179 38,562 38,944 39,326 39,706 40,087 40,466 40,845 41,223 41,600 41,976 42,352 42,727 43,101 43,474 43,846 44,218 44,588 44,958 45,326 45,694 46,060 46,425 46,789 47,152 47,513 0 1 2 3 4 5 6 1 28,494 28,886 29,279 29,671 30,063 30,455 30,846 31,238 31,629 32,020 32,410 32,800 33,190 33,580 33,969 34,358 34,746 35,134 35,521 35,908 36,294 36,680 37,065 37,450 37,834 38,217 38,600 38,982 39,364 39,744 40,125 40,504 40,883 41,260 41,638 42,014 42,390 42,764 43,138 43,511 43,884 44,255 44,625 44,995 45,363 45,731 46,097 46,462 46,826 47,188 2 28,533 28,926 29,318 29,710 30,102 30,494 30,886 31,277 31,668 32,059 32,449 32,839 33,229 33,619 34,008 34,396 34,785 35,172 35,560 35,946 36,333 36,718 37,104 37,488 37,872 38,256 38,638 39,020 39,402 39,783 40,163 40,542 40,920 41,298 41,675 42,052 42,427 42,802 43,176 43,549 43,921 44,292 44,662 45,032 45,400 45,767 46,133 46,498 46,862 47,224 3 28,572 28,965 29,357 29,749 30,141 30,533 30,925 31,316 31,707 32,098 32,488 32,878 33,268 33,658 34,047 34,435 34,823 35,211 35,598 35,985 36,371 36,757 37,142 37,527 37,911 38,294 38,677 39,059 39,440 39,821 40,201 40,580 40,958 41,336 41,713 42,089 42,465 42,839 43,213 43,586 43,958 44,329 44,699 45,069 45,437 45,804 46,170 46,535 46,898 47,260 4 28,612 29,004 29,396 29,789 30,181 30,572 30,964 31,355 31,746 32,137 32,527 32,917 33,307 33,697 34,086 34,474 34,862 35,250 35,637 36,024 36,410 36,796 37,181 37,565 37,949 38,332 38,715 39,097 39,478 39,859 40,238 40,618 40,996 41,374 41,751 42,127 42,502 42,877 43,250 43,623 43,995 44,366 44,736 45,105 45,474 45,841 46,207 46,571 46,935 47,296 5 28,651 29,043 29,436 29,828 30,220 30,611 31,003 31,394 31,785 32,176 32,566 32,956 33,346 33,736 34,124 34,513 34,901 35,289 35,676 36,062 36,449 36,834 37,219 37,603 37,987 38,370 38,753 39,135 39,516 39,897 40,276 40,655 41,034 41,411 41,788 42,164 42,540 42,914 43,288 43,660 44,032 44,403 44,773 45,142 45,510 45,877 46,243 46,608 46,971 47,333 6 28,690 29,083 29,475 29,867 30,259 30,651 31,042 31,433 31,824 32,215 32,605 32,995 33,385 33,774 34,163 34,552 34,940 35,327 35,714 36,101 36,487 36,873 37,258 37,642 38,026 38,409 38,791 39,173 39,554 39,935 40,314 40,693 41,072 41,449 41,826 42,202 42,577 42,951 43,325 43,698 44,069 44,440 44,810 45,179 45,547 45,914 46,280 46,644 47,007 47,369

THERMOCOUPLE
cold junction 0 C 7 28,729 29,122 29,514 29,906 30,298 30,690 31,081 31,473 31,863 32,254 32,644 33,034 33,424 33,813 34,202 34,591 34,979 35,366 35,753 36,140 36,526 36,911 37,296 37,680 38,064 38,447 38,829 39,211 39,592 39,973 40,352 40,731 41,109 41,487 41,864 42,239 42,614 42,989 43,362 43,735 44,106 44,477 44,847 45,216 45,584 45,951 46,316 46,680 47,043 47,405 7 8 28,769 29,161 29,553 29,945 30,337 30,729 31,120 31,512 31,903 32,293 32,683 33,073 33,463 33,852 34,241 34,629 35,017 35,405 35,792 36,178 36,564 36,950 37,334 37,719 38,102 38,485 38,868 39,249 39,630 40,011 40,390 40,769 41,147 41,525 41,901 42,277 42,652 43,026 43,399 43,772 44,144 44,514 44,884 45,253 45,621 45,987 46,353 46,717 47,079 47,441 8 9 28,808 29,200 29,592 29,985 30,376 30,768 31,160 31,551 31,942 32,332 32,722 33,112 33,502 33,891 34,280 34,668 35,056 35,444 35,831 36,217 36,603 36,988 37,373 37,757 38,141 38,524 38,906 39,287 39,668 40,049 40,428 40,807 41,185 41,562 41,939 42,314 42,689 43,064 43,437 43,809 44,181 44,551 44,921 45,290 45,657 46,024 46,389 46,753 47,116 47,477 9 10 28,847 29,239 29,632 30,024 30,416 30,807 31,199 31,590 31,981 32,371 32,761 33,151 33,541 33,930 34,319 34,707 35,095 35,482 35,869 36,256 36,641 37,027 37,411 37,795 38,179 38,562 38,944 39,326 39,706 40,087 40,466 40,845 41,223 41,600 41,976 42,352 42,727 43,101 43,474 43,846 44,218 44,588 44,958 45,326 45,694 46,060 46,425 46,789 47,152 47,513 10

TEMPERATURE RANGE (-270 +1300 C) CABLE COLOR CODING ANSI

CABLE COLOR CODING IEC 584-3

LA TERMOTECNICA
C -50 -40 -30 -20 -10 0 C C 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 C 0 -0,236 -0,194 -0,150 -0,103 -0,053 0,000 0 0 0,000 0,055 0,113 0,173 0,235 0,299 0,365 0,433 0,502 0,573 0,646 0,720 0,795 0,872 0,950 1,029 1,110 1,191 1,273 1,357 1,441 1,526 1,612 1,698 1,786 1,874 1,962 2,052 2,141 2,232 2,323 2,415 2,507 2,599 2,692 2,786 2,880 2,974 3,069 3,164 3,259 3,355 3,451 3,548 3,645 3,742 3,840 3,938 0 -0,199 -0,155 -0,108 -0,058 -0,005 -1 1 0,005 0,061 0,119 0,179 0,241 0,305 0,372 0,440 0,509 0,580 0,653 0,727 0,803 0,880 0,958 1,037 1,118 1,199 1,282 1,365 1,449 1,534 1,620 1,707 1,794 1,882 1,971 2,061 2,151 2,241 2,332 2,424 2,516 2,609 2,702 2,795 2,889 2,983 3,078 3,173 3,269 3,365 3,461 3,558 3,655 3,752 3,850 3,947 1 -0,203 -0,159 -0,113 -0,063 -0,011 -2 2 0,011 0,067 0,125 0,185 0,248 0,312 0,378 0,446 0,516 0,588 0,661 0,735 0,811 0,888 0,966 1,045 1,126 1,207 1,290 1,373 1,458 1,543 1,629 1,716 1,803 1,891 1,980 2,070 2,160 2,250 2,341 2,433 2,525 2,618 2,711 2,805 2,899 2,993 3,088 3,183 3,279 3,374 3,471 3,567 3,664 3,762 3,859 3,957 2 -0,207 -0,164 -0,117 -0,068 -0,016 -3 3 0,016 0,072 0,131 0,191 0,254 0,319 0,385 0,453 0,523 0,595 0,668 0,743 0,818 0,896 0,974 1,053 1,134 1,216 1,298 1,382 1,466 1,551 1,638 1,724 1,812 1,900 1,989 2,078 2,169 2,259 2,350 2,442 2,534 2,627 2,720 2,814 2,908 3,002 3,097 3,192 3,288 3,384 3,480 3,577 3,674 3,771 3,869 3,967 3 -0,211 -0,168 -0,122 -0,073 -0,021 -4 4 0,022 0,078 0,137 0,197 0,260 0,325 0,392 0,460 0,530 0,602 0,675 0,750 0,826 0,903 0,982 1,061 1,142 1,224 1,307 1,390 1,475 1,560 1,646 1,733 1,821 1,909 1,998 2,087 2,178 2,268 2,360 2,451 2,544 2,636 2,730 2,823 2,917 3,012 3,107 3,202 3,298 3,394 3,490 3,587 3,684 3,781 3,879 3,977 4 -0,215 -0,173 -0,127 -0,078 -0,027 -5 5 0,027 0,084 0,143 0,204 0,267 0,332 0,399 0,467 0,538 0,609 0,683 0,758 0,834 0,911 0,990 1,069 1,150 1,232 1,315 1,399 1,483 1,569 1,655 1,742 1,829 1,918 2,007 2,096 2,187 2,277 2,369 2,461 2,553 2,646 2,739 2,833 2,927 3,021 3,116 3,212 3,307 3,403 3,500 3,596 3,694 3,791 3,889 3,987 5 -0,219 -0,177 -0,132 -0,083 -0,032 -6 6 0,033 0,090 0,149 0,210 0,273 0,338 0,405 0,474 0,545 0,617 0,690 0,765 0,841 0,919 0,998 1,077 1,158 1,240 1,323 1,407 1,492 1,577 1,663 1,751 1,838 1,927 2,016 2,105 2,196 2,287 2,378 2,470 2,562 2,655 2,748 2,842 2,936 3,031 3,126 3,221 3,317 3,413 3,509 3,606 3,703 3,801 3,898 3,997 6 -1 -2 -3 -4 -5 -6

THERMOCOUPLE

F.E.M. output of a S type thermocouple(Platinum Vs. Platinum/10%Rhodium). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. cold junction 0 C -7 -0,224 -0,181 -0,136 -0,088 -0,037 -7 7 0,038 0,095 0,155 0,216 0,280 0,345 0,412 0,481 0,552 0,624 0,698 0,773 0,849 0,927 1,006 1,085 1,167 1,249 1,332 1,415 1,500 1,586 1,672 1,759 1,847 1,936 2,025 2,114 2,205 2,296 2,387 2,479 2,571 2,664 2,758 2,851 2,946 3,040 3,135 3,231 3,326 3,423 3,519 3,616 3,713 3,810 3,908 4,006 7 -8 -0,228 -0,186 -0,141 -0,093 -0,042 -8 8 0,044 0,101 0,161 0,222 0,286 0,352 0,419 0,488 0,559 0,631 0,705 0,780 0,857 0,935 1,013 1,094 1,175 1,257 1,340 1,424 1,509 1,594 1,681 1,768 1,856 1,944 2,034 2,123 2,214 2,305 2,396 2,488 2,581 2,674 2,767 2,861 2,955 3,050 3,145 3,240 3,336 3,432 3,529 3,626 3,723 3,820 3,918 4,016 8 -9 -0,232 -0,190 -0,146 -0,098 -0,048 -9 9 0,050 0,107 0,167 0,229 0,292 0,358 0,426 0,495 0,566 0,639 0,713 0,788 0,865 0,942 1,021 1,102 1,183 1,265 1,348 1,432 1,517 1,603 1,690 1,777 1,865 1,953 2,043 2,132 2,223 2,314 2,405 2,497 2,590 2,683 2,776 2,870 2,965 3,059 3,154 3,250 3,346 3,442 3,538 3,635 3,732 3,830 3,928 4,026 9 -10 -0,236 -0,194 -0,150 -0,103 -0,053 -10 10 0,055 0,113 0,173 0,235 0,299 0,365 0,433 0,502 0,573 0,646 0,720 0,795 0,872 0,950 1,029 1,110 1,191 1,273 1,357 1,441 1,526 1,612 1,698 1,786 1,874 1,962 2,052 2,141 2,232 2,323 2,415 2,507 2,599 2,692 2,786 2,880 2,974 3,069 3,164 3,259 3,355 3,451 3,548 3,645 3,742 3,840 3,938 4,036 10 CABLE COLOR CODING IEC 584-3 CABLE COLOR CODING ANSI TEMPERATURE RANGE (-50 +1768C)

LA TERMOTECNICA
C 470 480 490 500 510 520 530 540 550 560 570 580 590 600 610 620 630 640 650 660 670 680 690 700 710 720 730 740 750 760 770 780 790 800 810 820 830 840 850 860 870 880 890 900 910 920 930 940 950 960 970 980 990 1000 C 0 3,938 4,036 4,134 4,233 4,332 4,432 4,532 4,632 4,732 4,833 4,934 5,035 5,137 5,239 5,341 5,443 5,546 5,649 5,753 5,857 5,961 6,065 6,170 6,275 6,381 6,486 6,593 6,699 6,806 6,913 7,020 7,128 7,236 7,345 7,454 7,563 7,673 7,783 7,893 8,003 8,114 8,226 8,337 8,449 8,562 8,674 8,787 8,900 9,014 9,128 9,242 9,357 9,472 9,587 0 1 3,947 4,046 4,144 4,243 4,342 4,442 4,542 4,642 4,742 4,843 4,944 5,045 5,147 5,249 5,351 5,454 5,557 5,660 5,763 5,867 5,971 6,076 6,181 6,286 6,391 6,497 6,603 6,710 6,817 6,924 7,031 7,139 7,247 7,356 7,465 7,574 7,684 7,794 7,904 8,014 8,125 8,237 8,348 8,460 8,573 8,685 8,798 8,912 9,025 9,139 9,254 9,368 9,483 9,599 1 2 3,957 4,056 4,154 4,253 4,352 4,452 4,552 4,652 4,752 4,853 4,954 5,055 5,157 5,259 5,361 5,464 5,567 5,670 5,774 5,878 5,982 6,086 6,191 6,296 6,402 6,508 6,614 6,720 6,827 6,934 7,042 7,150 7,258 7,367 7,476 7,585 7,695 7,805 7,915 8,026 8,137 8,248 8,360 8,472 8,584 8,697 8,810 8,923 9,037 9,151 9,265 9,380 9,495 9,610 2 3 3,967 4,065 4,164 4,263 4,362 4,462 4,562 4,662 4,762 4,863 4,964 5,066 5,167 5,269 5,372 5,474 5,577 5,680 5,784 5,888 5,992 6,097 6,202 6,307 6,412 6,518 6,624 6,731 6,838 6,945 7,053 7,161 7,269 7,378 7,487 7,596 7,706 7,816 7,926 8,037 8,148 8,259 8,371 8,483 8,595 8,708 8,821 8,935 9,048 9,162 9,277 9,391 9,506 9,622 3 4 3,977 4,075 4,174 4,273 4,372 4,472 4,572 4,672 4,772 4,873 4,974 5,076 5,178 5,280 5,382 5,485 5,588 5,691 5,794 5,898 6,003 6,107 6,212 6,317 6,423 6,529 6,635 6,742 6,849 6,956 7,064 7,172 7,280 7,388 7,497 7,607 7,717 7,827 7,937 8,048 8,159 8,270 8,382 8,494 8,607 8,719 8,832 8,946 9,060 9,174 9,288 9,403 9,518 9,633 4 5 3,987 4,085 4,184 4,283 4,382 4,482 4,582 4,682 4,782 4,883 4,984 5,086 5,188 5,290 5,392 5,495 5,598 5,701 5,805 5,909 6,013 6,118 6,223 6,328 6,434 6,539 6,646 6,752 6,859 6,967 7,074 7,182 7,291 7,399 7,508 7,618 7,728 7,838 7,948 8,059 8,170 8,281 8,393 8,505 8,618 8,731 8,844 8,957 9,071 9,185 9,300 9,414 9,529 9,645 5 6 3,997 4,095 4,194 4,293 4,392 4,492 4,592 4,692 4,793 4,893 4,995 5,096 5,198 5,300 5,402 5,505 5,608 5,712 5,815 5,919 6,024 6,128 6,233 6,338 6,444 6,550 6,656 6,763 6,870 6,977 7,085 7,193 7,302 7,410 7,519 7,629 7,739 7,849 7,959 8,070 8,181 8,293 8,404 8,517 8,629 8,742 8,855 8,969 9,082 9,197 9,311 9,426 9,541 9,656 6

THERMOCOUPLE

F.E.M. output of a S type thermocouple(Platinum Vs. Platinum/10%Rhodium). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. cold junction 0 C 7 4,006 4,105 4,204 4,303 4,402 4,502 4,602 4,702 4,803 4,904 5,005 5,106 5,208 5,310 5,413 5,515 5,618 5,722 5,826 5,930 6,034 6,139 6,244 6,349 6,455 6,561 6,667 6,774 6,881 6,988 7,096 7,204 7,312 7,421 7,530 7,640 7,750 7,860 7,970 8,081 8,192 8,304 8,416 8,528 8,640 8,753 8,866 8,980 9,094 9,208 9,323 9,437 9,552 9,668 7 8 4,016 4,115 4,213 4,313 4,412 4,512 4,612 4,712 4,813 4,914 5,015 5,116 5,218 5,320 5,423 5,526 5,629 5,732 5,836 5,940 6,044 6,149 6,254 6,360 6,465 6,571 6,678 6,784 6,892 6,999 7,107 7,215 7,323 7,432 7,541 7,651 7,761 7,871 7,981 8,092 8,203 8,315 8,427 8,539 8,652 8,765 8,878 8,991 9,105 9,219 9,334 9,449 9,564 9,680 8 9 4,026 4,125 4,223 4,323 4,422 4,522 4,622 4,722 4,823 4,924 5,025 5,127 5,228 5,331 5,433 5,536 5,639 5,743 5,846 5,950 6,055 6,160 6,265 6,370 6,476 6,582 6,688 6,795 6,902 7,010 7,117 7,226 7,334 7,443 7,552 7,662 7,772 7,882 7,992 8,103 8,214 8,326 8,438 8,550 8,663 8,776 8,889 9,003 9,117 9,231 9,345 9,460 9,576 9,691 9 10 4,036 4,134 4,233 4,332 4,432 4,532 4,632 4,732 4,833 4,934 5,035 5,137 5,239 5,341 5,443 5,546 5,649 5,753 5,857 5,961 6,065 6,170 6,275 6,381 6,486 6,593 6,699 6,806 6,913 7,020 7,128 7,236 7,345 7,454 7,563 7,673 7,783 7,893 8,003 8,114 8,226 8,337 8,449 8,562 8,674 8,787 8,900 9,014 9,128 9,242 9,357 9,472 9,587 9,703 10 CABLE COLOR CODING IEC 584-3 CABLE COLOR CODING ANSI TEMPERATURE RANGE (-50 +1768C)

LA TERMOTECNICA
C 1000 1010 1020 1030 1040 1050 1060 1070 1080 1090 1100 1110 1120 1130 1140 1150 1160 1170 1180 1190 1200 1210 1220 1230 1240 1250 1260 1270 1280 1290 1300 1310 1320 1330 1340 1350 1360 1370 1380 1390 1400 1410 1420 1430 1440 1450 1460 1470 1480 1490 1500 1510 1520 1530 1540 1550 C 0 9,587 9,703 9,819 9,935 10,051 10,168 10,285 10,403 10,520 10,638 10,757 10,875 10,994 11,113 11,232 11,351 11,471 11,590 11,710 11,830 11,951 12,071 12,191 12,312 12,433 12,554 12,675 12,796 12,917 13,038 13,159 13,280 13,402 13,523 13,644 13,766 13,887 14,009 14,130 14,251 14,373 14,494 14,615 14,736 14,857 14,978 15,099 15,220 15,341 15,461 15,582 15,702 15,822 15,942 16,062 16,182 0 1 9,599 9,714 9,830 9,946 10,063 10,180 10,297 10,414 10,532 10,650 10,768 10,887 11,006 11,125 11,244 11,363 11,483 11,602 11,722 11,842 11,963 12,083 12,203 12,324 12,445 12,566 12,687 12,808 12,929 13,050 13,171 13,292 13,414 13,535 13,657 13,778 13,899 14,021 14,142 14,263 14,385 14,506 14,627 14,748 14,869 14,990 15,111 15,232 15,353 15,473 15,594 15,714 15,834 15,954 16,074 16,194 1 2 9,610 9,726 9,842 9,958 10,075 10,191 10,309 10,426 10,544 10,662 10,780 10,899 11,017 11,136 11,256 11,375 11,495 11,614 11,734 11,854 11,975 12,095 12,216 12,336 12,457 12,578 12,699 12,820 12,941 13,062 13,183 13,305 13,426 13,547 13,669 13,790 13,911 14,033 14,154 14,276 14,397 14,518 14,639 14,760 14,881 15,002 15,123 15,244 15,365 15,485 15,606 15,726 15,846 15,966 16,086 16,205 2 3 9,622 9,737 9,853 9,970 10,086 10,203 10,320 10,438 10,556 10,674 10,792 10,911 11,029 11,148 11,268 11,387 11,507 11,626 11,746 11,866 11,987 12,107 12,228 12,348 12,469 12,590 12,711 12,832 12,953 13,074 13,195 13,317 13,438 13,559 13,681 13,802 13,924 14,045 14,166 14,288 14,409 14,530 14,651 14,773 14,894 15,015 15,135 15,256 15,377 15,497 15,618 15,738 15,858 15,978 16,098 16,217 3 4 9,633 9,749 9,865 9,981 10,098 10,215 10,332 10,450 10,567 10,686 10,804 10,922 11,041 11,160 11,280 11,399 11,519 11,638 11,758 11,878 11,999 12,119 12,240 12,360 12,481 12,602 12,723 12,844 12,965 13,086 13,208 13,329 13,450 13,572 13,693 13,814 13,936 14,057 14,178 14,300 14,421 14,542 14,664 14,785 14,906 15,027 15,148 15,268 15,389 15,509 15,630 15,750 15,870 15,990 16,110 16,229 4 5 9,645 9,761 9,877 9,993 10,109 10,227 10,344 10,461 10,579 10,697 10,816 10,934 11,053 11,172 11,291 11,411 11,531 11,650 11,770 11,890 12,011 12,131 12,252 12,372 12,493 12,614 12,735 12,856 12,977 13,098 13,220 13,341 13,462 13,584 13,705 13,826 13,948 14,069 14,191 14,312 14,433 14,554 14,676 14,797 14,918 15,039 15,160 15,280 15,401 15,521 15,642 15,762 15,882 16,002 16,122 16,241 5 6 9,656 9,772 9,888 10,005 10,121 10,238 10,356 10,473 10,591 10,709 10,828 10,946 11,065 11,184 11,303 11,423 11,542 11,662 11,782 11,902 12,023 12,143 12,264 12,384 12,505 12,626 12,747 12,868 12,989 13,111 13,232 13,353 13,474 13,596 13,717 13,839 13,960 14,081 14,203 14,324 14,445 14,567 14,688 14,809 14,930 15,051 15,172 15,292 15,413 15,534 15,654 15,774 15,894 16,014 16,134 16,253 6

THERMOCOUPLE

F.E.M. output of a S type thermocouple(Platinum Vs. Platinum/10%Rhodium). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. cold junction 0 C 7 9,668 9,784 9,900 10,016 10,133 10,250 10,367 10,485 10,603 10,721 10,839 10,958 11,077 11,196 11,315 11,435 11,554 11,674 11,794 11,914 12,035 12,155 12,276 12,397 12,517 12,638 12,759 12,880 13,001 13,123 13,244 13,365 13,487 13,608 13,729 13,851 13,972 14,094 14,215 14,336 14,457 14,579 14,700 14,821 14,942 15,063 15,184 15,304 15,425 15,546 15,666 15,786 15,906 16,026 16,146 16,265 7 8 9,680 9,795 9,911 10,028 10,145 10,262 10,379 10,497 10,615 10,733 10,851 10,970 11,089 11,208 11,327 11,447 11,566 11,686 11,806 11,926 12,047 12,167 12,288 12,409 12,529 12,650 12,771 12,892 13,014 13,135 13,256 13,377 13,499 13,620 13,742 13,863 13,984 14,106 14,227 14,348 14,470 14,591 14,712 14,833 14,954 15,075 15,196 15,317 15,437 15,558 15,678 15,798 15,918 16,038 16,158 16,277 8 9 9,691 9,807 9,923 10,040 10,156 10,273 10,391 10,509 10,626 10,745 10,863 10,982 11,101 11,220 11,339 11,459 11,578 11,698 11,818 11,939 12,059 12,179 12,300 12,421 12,542 12,662 12,783 12,905 13,026 13,147 13,268 13,390 13,511 13,632 13,754 13,875 13,996 14,118 14,239 14,360 14,482 14,603 14,724 14,845 14,966 15,087 15,208 15,329 15,449 15,570 15,690 15,810 15,930 16,050 16,170 16,289 9 10 9,703 9,819 9,935 10,051 10,168 10,285 10,403 10,520 10,638 10,757 10,875 10,994 11,113 11,232 11,351 11,471 11,590 11,710 11,830 11,951 12,071 12,191 12,312 12,433 12,554 12,675 12,796 12,917 13,038 13,159 13,280 13,402 13,523 13,644 13,766 13,887 14,009 14,130 14,251 14,373 14,494 14,615 14,736 14,857 14,978 15,099 15,220 15,341 15,461 15,582 15,702 15,822 15,942 16,062 16,182 16,301 10 CABLE COLOR CODING IEC 584-3 CABLE COLOR CODING ANSI TEMPERATURE RANGE (-50 +1768C)

LA TERMOTECNICA

THERMOCOUPLE

F.E.M. output of a S type thermocouple(Platinum Vs. Platinum/10%Rhodium). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. cold junction 0 C

C 1550 1560 1570 1580 1590 1600 1610 1620 1630 1640 1650 1660 1670 1680 1690 1700 1710 1720 1730 1740 1750 1760 C

0 16,182 16,301 16,420 16,539 16,658 16,777 16,895 17,013 17,131 17,249 17,366 17,483 17,600 17,717 17,832 17,947 18,061 18,174 18,285 18,395 18,503 18,609 0

1 16,194 16,313 16,432 16,551 16,670 16,789 16,907 17,025 17,143 17,261 17,378 17,495 17,612 17,728 17,844 17,959 18,073 18,185 18,297 18,406 18,514 18,620 1

2 16,205 16,325 16,444 16,563 16,682 16,801 16,919 17,037 17,155 17,272 17,390 17,507 17,623 17,740 17,855 17,970 18,084 18,196 18,308 18,417 18,525 18,630 2

3 16,217 16,337 16,456 16,575 16,694 16,812 16,931 17,049 17,167 17,284 17,401 17,518 17,635 17,751 17,867 17,982 18,095 18,208 18,319 18,428 18,535 18,641 3

4 16,229 16,349 16,468 16,587 16,706 16,824 16,943 17,061 17,178 17,296 17,413 17,530 17,647 17,763 17,878 17,993 18,107 18,219 18,330 18,439 18,546 18,651 4

5 16,241 16,361 16,480 16,599 16,718 16,836 16,954 17,072 17,190 17,308 17,425 17,542 17,658 17,775 17,890 18,004 18,118 18,230 18,341 18,449 18,557 18,661 5

6 16,253 16,373 16,492 16,611 16,729 16,848 16,966 17,084 17,202 17,319 17,437 17,553 17,670 17,786 17,901 18,016 18,129 18,241 18,352 18,460 18,567 18,672 6

7 16,265 16,385 16,504 16,623 16,741 16,860 16,978 17,096 17,214 17,331 17,448 17,565 17,682 17,798 17,913 18,027 18,140 18,252 18,362 18,471 18,578 18,682 7

8 16,277 16,396 16,516 16,634 16,753 16,872 16,990 17,108 17,225 17,343 17,460 17,577 17,693 17,809 17,924 18,039 18,152 18,263 18,373 18,482 18,588 18,693 8

9 16,289 16,408 16,527 16,646 16,765 16,883 17,002 17,120 17,237 17,355 17,472 17,588 17,705 17,821 17,936 18,050 18,163 18,274 18,384 18,493 18,599 9

10 16,301 16,420 16,539 16,658 16,777 16,895 17,013 17,131 17,249 17,366 17,483 17,600 17,717 17,832 17,947 18,061 18,174 18,285 18,395 18,503 18,609 10 CABLE COLOR CODING ANSI TEMPERATURE RANGE (-50 +1768C)

LA TERMOTECNICA
F.E.M. output of a E type thermocouple(Costantan Vs.Copper/Nichel). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. C -270 -260 -250 -240 -230 -220 -210 -200 -190 -180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 C C 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 C 0 -9,835 -9,797 -9,718 -9,604 -9,455 -9,274 -9,063 -8,825 -8,561 -8,273 -7,963 -7,632 -7,279 -6,907 -6,516 -6,107 -5,681 -5,237 -4,777 -4,302 -3,811 -3,306 -2,787 -2,255 -1,709 -1,152 -0,582 0,000 0 0 0,000 0,591 1,192 1,801 2,420 3,048 3,685 4,330 4,985 5,648 6,319 6,998 7,685 8,379 9,081 9,789 10,503 11,224 11,951 12,684 13,421 14,164 14,912 15,664 16,420 17,181 0 -9,802 -9,728 -9,617 -9,471 -9,293 -9,085 -8,850 -8,588 -8,303 -7,995 -7,666 -7,315 -6,945 -6,556 -6,149 -5,724 -5,282 -4,824 -4,350 -3,861 -3,357 -2,840 -2,309 -1,765 -1,208 -0,639 -0,059 -1 1 0,059 0,651 1,252 1,862 2,482 3,111 3,749 4,395 5,051 5,714 6,386 7,066 7,754 8,449 9,151 9,860 10,575 11,297 12,024 12,757 13,495 14,239 14,987 15,739 16,496 17,257 1 -9,808 -9,737 -9,630 -9,487 -9,313 -9,107 -8,874 -8,616 -8,333 -8,027 -7,700 -7,351 -6,983 -6,596 -6,191 -5,767 -5,327 -4,871 -4,398 -3,911 -3,408 -2,892 -2,362 -1,820 -1,264 -0,697 -0,117 -2 2 0,118 0,711 1,313 1,924 2,545 3,174 3,813 4,460 5,117 5,781 6,454 7,135 7,823 8,519 9,222 9,931 10,647 11,369 12,097 12,831 13,569 14,313 15,062 15,815 16,572 17,333 2 -9,813 -9,746 -9,642 -9,503 -9,331 -9,129 -8,899 -8,643 -8,362 -8,059 -7,733 -7,387 -7,021 -6,636 -6,232 -5,810 -5,372 -4,917 -4,446 -3,960 -3,459 -2,944 -2,416 -1,874 -1,320 -0,754 -0,176 -3 3 0,176 0,770 1,373 1,986 2,607 3,238 3,877 4,526 5,183 5,848 6,522 7,203 7,892 8,589 9,292 10,003 10,719 11,442 12,170 12,904 13,644 14,388 15,137 15,890 16,648 17,409 3 -9,817 -9,754 -9,654 -9,519 -9,350 -9,151 -8,923 -8,669 -8,391 -8,090 -7,767 -7,423 -7,058 -6,675 -6,273 -5,853 -5,417 -4,963 -4,494 -4,009 -3,510 -2,996 -2,469 -1,929 -1,376 -0,811 -0,234 -4 4 0,235 0,830 1,434 2,047 2,670 3,301 3,942 4,591 5,249 5,915 6,590 7,272 7,962 8,659 9,363 10,074 10,791 11,514 12,243 12,978 13,718 14,463 15,212 15,966 16,724 17,486 4 -9,821 -9,762 -9,666 -9,534 -9,368 -9,172 -8,947 -8,696 -8,420 -8,121 -7,800 -7,458 -7,096 -6,714 -6,314 -5,896 -5,461 -5,009 -4,542 -4,058 -3,561 -3,048 -2,523 -1,984 -1,432 -0,868 -0,292 -5 5 0,294 0,890 1,495 2,109 2,733 3,365 4,006 4,656 5,315 5,982 6,658 7,341 8,031 8,729 9,434 10,145 10,863 11,587 12,317 13,052 13,792 14,537 15,287 16,041 16,800 17,562 5 -9,825 -9,770 -9,677 -9,548 -9,386 -9,193 -8,971 -8,722 -8,449 -8,152 -7,833 -7,493 -7,133 -6,753 -6,355 -5,939 -5,505 -5,055 -4,589 -4,107 -3,611 -3,100 -2,576 -2,038 -1,488 -0,925 -0,350 -6 6 0,354 0,950 1,556 2,171 2,795 3,429 4,071 4,722 5,382 6,049 6,725 7,409 8,101 8,799 9,505 10,217 10,935 11,660 12,390 13,126 13,866 14,612 15,362 16,117 16,876 17,639 6 -1 -2 -3 -4 -5 -6

THERMOCOUPLE
cold junction 0 C -7 -9,828 -9,777 -9,688 -9,563 -9,404 -9,214 -8,994 -8,748 -8,477 -8,183 -7,866 -7,528 -7,170 -6,792 -6,396 -5,981 -5,549 -5,101 -4,636 -4,156 -3,661 -3,152 -2,629 -2,093 -1,543 -0,982 -0,408 -7 7 0,413 1,010 1,617 2,233 2,858 3,492 4,136 4,788 5,448 6,117 6,794 7,478 8,170 8,869 9,576 10,288 11,007 11,733 12,463 13,199 13,941 14,687 15,438 16,193 16,952 17,715 7 -8 -9,831 -9,784 -9,698 -9,577 -9,421 -9,234 -9,017 -8,774 -8,505 -8,213 -7,899 -7,563 -7,206 -6,831 -6,436 -6,023 -5,593 -5,147 -4,684 -4,205 -3,711 -3,204 -2,682 -2,147 -1,599 -1,039 -0,466 -8 8 0,472 1,071 1,678 2,295 2,921 3,556 4,200 4,853 5,514 6,184 6,862 7,547 8,240 8,940 9,647 10,360 11,080 11,805 12,537 13,273 14,015 14,762 15,513 16,269 17,028 17,792 8 -9 -9,833 -9,790 -9,709 -9,591 -9,438 -9,254 -9,040 -8,799 -8,533 -8,243 -7,931 -7,597 -7,243 -6,869 -6,476 -6,065 -5,637 -5,192 -4,731 -4,254 -3,761 -3,255 -2,735 -2,201 -1,654 -1,095 -0,524 -9 9 0,532 1,131 1,740 2,357 2,984 3,620 4,265 4,919 5,581 6,251 6,930 7,616 8,309 9,010 9,718 10,432 11,152 11,878 12,610 13,347 14,090 14,837 15,588 16,344 17,104 17,868 9 -10 -9,835 -9,797 -9,718 -9,604 -9,455 -9,274 -9,063 -8,825 -8,561 -8,273 -7,963 -7,632 -7,279 -6,907 -6,516 -6,107 -5,681 -5,237 -4,777 -4,302 -3,811 -3,306 -2,787 -2,255 -1,709 -1,152 -0,582 -10 10 0,591 1,192 1,801 2,420 3,048 3,685 4,330 4,985 5,648 6,319 6,998 7,685 8,379 9,081 9,789 10,503 11,224 11,951 12,684 13,421 14,164 14,912 15,664 16,420 17,181 17,945 10

TEMPERATURE RANGE (-270 +1000 C) CABLE COLOR CODING ANSI

CABLE COLOR CODING IEC 584-3

LA TERMOTECNICA
F.E.M. output of a E type thermocouple(Costantan Vs.Copper/Nichel). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90. C 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600 610 620 630 640 650 660 670 680 690 700 710 720 730 740 750 760 770 780 790 800 C 0 17,181 17,945 18,713 19,484 20,259 21,036 21,817 22,600 23,386 24,174 24,964 25,757 26,552 27,348 28,146 28,946 29,747 30,550 31,354 32,159 32,965 33,772 34,579 35,387 36,196 37,005 37,815 38,624 39,434 40,243 41,053 41,862 42,671 43,479 44,286 45,093 45,900 46,705 47,509 48,313 49,116 49,917 50,718 51,517 52,315 53,112 53,908 54,703 55,497 56,289 57,080 57,870 58,659 59,446 60,232 61,017 0 1 17,257 18,021 18,790 19,561 20,336 21,114 21,895 22,678 23,464 24,253 25,044 25,836 26,631 27,428 28,226 29,026 29,827 30,630 31,434 32,239 33,045 33,852 34,660 35,468 36,277 37,086 37,896 38,705 39,515 40,324 41,134 41,943 42,751 43,560 44,367 45,174 45,980 46,785 47,590 48,393 49,196 49,997 50,798 51,597 52,395 53,192 53,988 54,782 55,576 56,368 57,159 57,949 58,738 59,525 60,311 61,096 1 2 17,333 18,098 18,867 19,639 20,414 21,192 21,973 22,757 23,543 24,332 25,123 25,916 26,711 27,507 28,306 29,106 29,908 30,711 31,515 32,320 33,126 33,933 34,741 35,549 36,358 37,167 37,977 38,786 39,596 40,405 41,215 42,024 42,832 43,640 44,448 45,255 46,061 46,866 47,670 48,474 49,276 50,077 50,878 51,677 52,475 53,272 54,067 54,862 55,655 56,447 57,238 58,028 58,816 59,604 60,390 61,174 2 3 17,409 18,175 18,944 19,716 20,492 21,270 22,051 22,835 23,622 24,411 25,202 25,995 26,790 27,587 28,386 29,186 29,988 30,791 31,595 32,400 33,207 34,014 34,822 35,630 36,439 37,248 38,058 38,867 39,677 40,486 41,296 42,105 42,913 43,721 44,529 45,335 46,141 46,946 47,751 48,554 49,356 50,157 50,958 51,757 52,555 53,351 54,147 54,941 55,734 56,526 57,317 58,107 58,895 59,682 60,468 61,253 3 4 17,486 18,252 19,021 19,794 20,569 21,348 22,130 22,914 23,701 24,490 25,281 26,075 26,870 27,667 28,466 29,266 30,068 30,871 31,676 32,481 33,287 34,095 34,902 35,711 36,520 37,329 38,139 38,948 39,758 40,567 41,377 42,185 42,994 43,802 44,609 45,416 46,222 47,027 47,831 48,634 49,436 50,238 51,038 51,837 52,634 53,431 54,226 55,021 55,814 56,606 57,396 58,186 58,974 59,761 60,547 61,331 4 5 17,562 18,328 19,098 19,871 20,647 21,426 22,208 22,993 23,780 24,569 25,360 26,154 26,950 27,747 28,546 29,346 30,148 30,952 31,756 32,562 33,368 34,175 34,983 35,792 36,601 37,410 38,220 39,029 39,839 40,648 41,457 42,266 43,075 43,883 44,690 45,497 46,302 47,107 47,911 48,715 49,517 50,318 51,118 51,916 52,714 53,510 54,306 55,100 55,893 56,685 57,475 58,265 59,053 59,839 60,625 61,409 5 6 17,639 18,405 19,175 19,948 20,725 21,504 22,286 23,071 23,858 24,648 25,440 26,233 27,029 27,827 28,626 29,427 30,229 31,032 31,837 32,642 33,449 34,256 35,064 35,873 36,682 37,491 38,300 39,110 39,920 40,729 41,538 42,347 43,156 43,963 44,771 45,577 46,383 47,188 47,992 48,795 49,597 50,398 51,197 51,996 52,794 53,590 54,385 55,179 55,972 56,764 57,554 58,343 59,131 59,918 60,704 61,488 6

THERMOCOUPLE
cold junction 0 C 7 17,715 18,482 19,252 20,026 20,803 21,582 22,365 23,150 23,937 24,727 25,519 26,313 27,109 27,907 28,706 29,507 30,309 31,112 31,917 32,723 33,529 34,337 35,145 35,954 36,763 37,572 38,381 39,191 40,001 40,810 41,619 42,428 43,236 44,044 44,851 45,658 46,463 47,268 48,072 48,875 49,677 50,478 51,277 52,076 52,873 53,670 54,465 55,259 56,051 56,843 57,633 58,422 59,210 59,997 60,782 61,566 7 8 17,792 18,559 19,330 20,103 20,880 21,660 22,443 23,228 24,016 24,806 25,598 26,392 27,189 27,986 28,786 29,587 30,389 31,193 31,998 32,803 33,610 34,418 35,226 36,034 36,843 37,653 38,462 39,272 40,082 40,891 41,700 42,509 43,317 44,125 44,932 45,738 46,544 47,349 48,152 48,955 49,757 50,558 51,357 52,156 52,953 53,749 54,544 55,338 56,131 56,922 57,712 58,501 59,289 60,075 60,860 61,644 8 9 17,868 18,636 19,407 20,181 20,958 21,739 22,522 23,307 24,095 24,885 25,678 26,472 27,268 28,066 28,866 29,667 30,470 31,273 32,078 32,884 33,691 34,498 35,307 36,115 36,924 37,734 38,543 39,353 40,163 40,972 41,781 42,590 43,398 44,206 45,013 45,819 46,624 47,429 48,233 49,035 49,837 50,638 51,437 52,236 53,033 53,829 54,624 55,417 56,210 57,001 57,791 58,580 59,367 60,154 60,939 61,723 9 10 17,945 18,713 19,484 20,259 21,036 21,817 22,600 23,386 24,174 24,964 25,757 26,552 27,348 28,146 28,946 29,747 30,550 31,354 32,159 32,965 33,772 34,579 35,387 36,196 37,005 37,815 38,624 39,434 40,243 41,053 41,862 42,671 43,479 44,286 45,093 45,900 46,705 47,509 48,313 49,116 49,917 50,718 51,517 52,315 53,112 53,908 54,703 55,497 56,289 57,080 57,870 58,659 59,446 60,232 61,017 61,801 10

TEMPERATURE RANGE (-270 +1000 C) CABLE COLOR CODING ANSI

CABLE COLOR CODING IEC 584-3

LA TERMOTECNICA
F.E.M. output of a E type thermocouple(Costantan Vs.Copper/Nichel). Temperature[C] vs. F.e.m. [mV] IEC 584-1. - ITS-90.

THERMOCOUPLE
cold junction 0 C

C 800 810 820 830 840 850 860 870 880 890 900 910 920 930 940 950 960 970 980 990 1000 C

0 61,017 61,801 62,583 63,364 64,144 64,922 65,698 66,473 67,246 68,017 68,787 69,554 70,319 71,082 71,844 72,603 73,360 74,115 74,869 75,621 76,373 0

1 61,096 61,879 62,662 63,442 64,222 65,000 65,776 66,550 67,323 68,094 68,863 69,631 70,396 71,159 71,920 72,678 73,435 74,190 74,944 75,696 1

2 61,174 61,958 62,740 63,520 64,300 65,077 65,853 66,628 67,400 68,171 68,940 69,707 70,472 71,235 71,996 72,754 73,511 74,266 75,019 75,771 2

3 61,253 62,036 62,818 63,598 64,377 65,155 65,931 66,705 67,478 68,248 69,017 69,784 70,548 71,311 72,072 72,830 73,586 74,341 75,095 75,847 3

4 61,331 62,114 62,896 63,676 64,455 65,233 66,008 66,782 67,555 68,325 69,094 69,860 70,625 71,387 72,147 72,906 73,662 74,417 75,170 75,922 4

5 61,409 62,192 62,974 63,754 64,533 65,310 66,086 66,860 67,632 68,402 69,171 69,937 70,701 71,463 72,223 72,981 73,738 74,492 75,245 75,997 5

6 61,488 62,271 63,052 63,832 64,611 65,388 66,163 66,937 67,709 68,479 69,247 70,013 70,777 71,539 72,299 73,057 73,813 74,567 75,320 76,072 6

7 61,566 62,349 63,130 63,910 64,689 65,465 66,241 67,014 67,786 68,556 69,324 70,090 70,854 71,615 72,375 73,133 73,889 74,643 75,395 76,147 7

8 61,644 62,427 63,208 63,988 64,766 65,543 66,318 67,092 67,863 68,633 69,401 70,166 70,930 71,692 72,451 73,208 73,964 74,718 75,471 76,223 8

9 61,723 62,505 63,286 64,066 64,844 65,621 66,396 67,169 67,940 68,710 69,477 70,243 71,006 71,768 72,527 73,284 74,040 74,793 75,546 76,298 9

10 61,801 62,583 63,364 64,144 64,922 65,698 66,473 67,246 68,017 68,787 69,554 70,319 71,082 71,844 72,603 73,360 74,115 74,869 75,621 76,373 10 CABLE COLOR CODING ANSI TEMPERATURE RANGE (-270 +1000 C)

LA TERMOTECNICA
Ohm output of a PT100 probe. Temperature[C] vs. resistance [Ohm] IEC 751. - ITS-90. C -200 -190 -180 -170 -160 -150 -140 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 C C 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 C 0 18,493 22,803 27,078 31,320 35,531 39,714 43,869 47,999 52,106 56,190 60,254 64,299 68,325 72,335 76,328 80,307 84,271 88,222 92,160 96,086 22,374 26,652 30,897 35,111 39,297 43,455 47,587 51,696 55,783 59,849 63,895 67,923 71,934 75,930 79,910 83,875 87,828 91,767 95,694 21,944 26,226 30,474 34,691 38,879 43,040 47,175 51,286 55,375 59,443 63,491 67,521 71,534 75,531 79,512 83,479 87,433 91,374 95,302 99,218 -2 2 21,514 25,799 30,051 34,271 38,462 42,625 46,763 50,876 54,967 59,037 63,087 67,119 71,134 75,132 79,115 83,083 87,038 90,980 94,910 98,827 -3 3 21,083 25,372 29,627 33,850 38,044 42,210 46,350 50,466 54,559 58,631 62,683 66,717 70,733 74,733 78,717 82,687 86,643 90,587 94,517 98,436 -4 4 20,653 24,945 29,203 33,429 37,626 41,795 45,937 50,055 54,151 58,225 62,279 66,314 70,332 74,333 78,319 82,291 86,248 90,193 94,125 98,045 -5 5 20,221 24,517 28,779 33,008 37,208 41,379 45,524 49,645 53,742 57,818 61,874 65,911 69,931 73,934 77,921 81,894 85,853 89,799 93,732 97,653 -6 6 -1 -2 -3 -4 -5 -6

TERMORESISTANCE

PT100

-7 19,790 24,089 28,354 32,587 36,789 40,963 45,111 49,234 53,333 57,412 61,469 65,508 69,530 73,534 77,523 81,498 85,458 89,405 93,339 97,262 -7 7

-8 19,358 23,661 27,929 32,165 36,370 40,547 44,697 48,822 52,924 57,005 61,065 65,105 69,128 73,135 77,125 81,101 85,063 89,011 92,946 96,870 -8 8

-9 18,926 23,232 27,504 31,742 35,951 40,130 44,283 48,411 52,515 56,598 60,659 64,702 68,727 72,735 76,727 80,704 84,667 88,617 92,553 96,478 -9 9

-10 18,493 22,803 27,078 31,320 35,531 39,714 43,869 47,999 52,106 56,190 60,254 64,299 68,325 72,335 76,328 80,307 84,271 88,222 92,160 96,086 -10 10

100,000 99,609 0 -1 0 1

100,000 100,391 100,781 101,172 101,562 101,953 102,343 102,733 103,123 103,513 103,902 103,902 104,292 104,681 105,071 105,460 105,849 106,238 106,627 107,016 107,404 107,793 107,793 108,181 108,570 108,958 109,346 109,734 110,122 110,509 110,897 111,284 111,672 111,672 112,059 112,446 112,833 113,220 113,607 113,994 114,380 114,767 115,153 115,539 115,539 115,925 116,311 116,697 117,083 117,469 117,854 118,240 118,625 119,010 119,395 119,395 119,780 120,165 120,550 120,934 121,319 121,703 122,087 122,471 122,855 123,239 123,239 123,623 124,007 124,390 124,774 125,157 125,540 125,923 126,306 126,689 127,072 127,072 127,454 127,837 128,219 128,602 128,984 129,366 129,748 130,130 130,511 130,893 130,893 131,274 131,656 132,037 132,418 132,799 133,180 133,561 133,941 134,322 134,702 134,702 135,083 135,463 135,843 136,223 136,603 136,982 137,362 137,741 138,121 138,500 138,500 138,879 139,258 139,637 140,016 140,395 140,773 141,152 141,530 141,908 142,286 142,286 142,664 143,042 143,420 143,797 144,175 144,552 144,930 145,307 145,684 146,061 146,061 146,438 146,814 147,191 147,567 147,944 148,320 148,696 149,072 149,448 149,824 149,824 150,199 150,575 150,950 151,326 151,701 152,076 152,451 152,826 153,200 153,575 153,575 153,950 154,324 154,698 155,072 155,446 155,820 156,194 156,568 156,941 157,315 157,315 157,688 158,061 158,435 158,808 159,180 159,553 159,926 160,298 160,671 161,043 161,043 161,415 161,787 162,159 162,531 162,903 163,274 163,646 164,017 164,388 164,760 164,760 165,131 165,501 165,872 166,243 166,613 166,984 167,354 167,724 168,095 168,465 168,465 168,834 169,204 169,574 169,943 170,313 170,682 171,051 171,420 171,789 172,158 172,158 172,527 172,895 173,264 173,632 174,000 174,368 174,736 175,104 175,472 175,840 175,840 176,207 176,575 176,942 177,309 177,676 178,043 178,410 178,777 179,143 179,510 179,510 179,876 180,242 180,609 180,975 181,340 181,706 182,072 182,437 182,803 183,168 183,168 183,533 183,899 184,264 184,628 184,993 185,358 185,722 186,087 186,451 186,815 186,815 187,179 187,543 187,907 188,271 188,634 188,998 189,361 189,724 190,088 190,451 190,451 190,813 191,176 191,539 191,901 192,264 192,626 192,988 193,350 193,712 194,074 194,074 194,436 194,798 195,159 195,520 195,882 196,243 196,604 196,965 197,326 197,686 197,686 198,047 198,407 198,768 199,128 199,488 199,848 200,208 200,568 200,927 201,287 201,287 204,876 208,453 212,019 215,573 219,115 0 201,646 205,234 208,810 212,375 215,928 219,469 1 202,006 205,592 209,167 212,731 216,282 219,822 2 202,365 205,950 209,524 213,086 216,637 220,176 3 202,724 206,308 209,881 213,442 216,991 220,529 4 203,083 206,666 210,237 213,797 217,346 220,882 5 203,442 207,024 210,594 214,153 217,700 221,235 6 203,800 207,381 210,950 214,508 218,054 221,588 7 204,159 207,739 211,307 214,863 218,408 221,941 8 204,517 208,096 211,663 215,218 218,762 222,294 9 204,876 208,453 212,019 215,573 219,115 222,646 10

LA TERMOTECNICA
Ohm output of a PT100 probe. Temperature[C] vs. resistance [Ohm] IEC 751. - ITS-90. C 330 340 350 360 370 380 390 400 410 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600 610 620 630 640 650 660 670 680 690 700 710 720 730 740 750 760 770 780 790 800 0 1 2 3 4 5 6

TERMORESISTANCE

PT100

10

222,646 222,999 223,351 223,703 224,055 224,407 224,759 225,111 225,463 225,814 226,166 226,166 226,517 226,868 227,219 227,570 227,921 228,272 228,622 228,973 229,323 229,673 229,673 230,023 230,373 230,723 231,073 231,423 231,772 232,122 232,471 232,820 233,169 233,169 233,518 233,867 234,216 234,565 234,913 235,261 235,610 235,958 236,306 236,654 236,654 237,002 237,349 237,697 238,044 238,392 238,739 239,086 239,433 239,780 240,127 240,127 240,473 240,820 241,166 241,513 241,859 242,205 242,551 242,897 243,242 243,588 243,588 243,933 244,279 244,624 244,969 245,314 245,659 246,004 246,349 246,693 247,038 247,038 247,382 247,726 248,070 248,414 248,758 249,102 249,445 249,789 250,132 250,476 250,476 250,819 251,162 251,505 251,848 252,190 252,533 252,875 253,218 253,560 253,902 250,476 250,819 251,162 251,505 251,848 252,190 252,533 252,875 253,218 253,560 253,902 253,902 254,244 254,586 254,928 255,269 255,611 255,952 256,294 256,635 256,976 257,317 257,317 257,658 257,999 258,339 258,680 259,020 259,360 259,700 260,040 260,380 260,720 260,720 261,060 261,399 261,739 262,078 262,417 262,757 263,096 263,434 263,773 264,112 264,112 264,450 264,789 265,127 265,465 265,803 266,141 266,479 266,817 267,154 267,492 267,492 267,829 268,167 268,504 268,841 269,178 269,514 269,851 270,188 270,524 270,860 270,860 271,197 271,533 271,869 272,204 272,540 272,876 273,211 273,547 273,882 274,217 274,217 274,552 274,887 275,222 275,557 275,891 276,226 276,560 276,894 277,228 277,562 277,562 277,896 278,230 278,564 278,897 279,231 279,564 279,897 280,230 280,563 280,896 280,896 281,229 281,561 281,894 282,226 282,558 282,891 283,223 283,555 283,886 284,218 284,218 284,550 284,881 285,212 285,544 285,875 286,206 286,537 286,867 287,198 287,528 287,528 287,859 288,189 288,519 288,849 289,179 289,509 289,839 290,168 290,498 290,827 290,827 291,156 291,486 291,815 292,144 292,472 292,801 293,130 293,458 293,786 294,114 294,114 294,443 294,770 295,098 295,426 295,754 296,081 296,409 296,736 297,063 297,390 297,390 297,717 298,044 298,370 298,697 299,023 299,350 299,676 300,002 300,328 300,654 300,654 300,980 301,305 301,631 301,956 302,282 302,607 302,932 303,257 303,582 303,906 303,906 304,231 304,556 304,880 305,204 305,528 305,852 306,176 306,500 306,824 307,147 307,147 307,471 307,794 308,117 308,440 308,763 309,086 309,409 309,732 310,054 310,376 310,376 310,699 311,021 311,343 311,665 311,987 312,308 312,630 312,951 313,273 313,594 313,594 313,915 314,236 314,557 314,878 315,198 315,519 315,839 316,160 316,480 316,800 316,800 317,120 317,440 317,760 318,079 318,399 318,718 319,037 319,356 319,675 319,994 319,994 320,313 320,632 320,950 321,269 321,587 321,905 322,224 322,541 322,859 323,177 323,177 323,495 323,812 324,130 324,447 324,764 325,081 325,398 325,715 326,032 326,348 326,348 326,665 326,981 327,297 327,614 327,930 328,245 328,561 328,877 329,192 329,508 329,508 329,823 330,138 330,453 330,768 331,083 331,398 331,713 332,027 332,342 332,656 332,656 332,970 333,284 333,598 333,912 334,225 334,539 334,852 335,166 335,479 335,792 335,792 336,105 336,418 336,731 337,043 337,356 337,668 337,981 338,293 338,605 338,917 338,917 339,229 339,540 339,852 340,164 340,475 340,786 341,097 341,408 341,719 342,030 342,030 342,341 342,651 342,962 343,272 343,582 343,892 344,202 344,512 344,822 345,132 345,132 345,441 345,751 346,060 346,369 346,678 346,987 347,296 347,604 347,913 348,222 348,222 348,530 348,838 349,146 349,454 349,762 350,070 350,378 350,685 350,993 351,300 351,300 351,607 351,914 352,221 352,528 352,835 353,141 353,448 353,754 354,060 354,367 354,367 354,673 354,979 355,284 355,590 355,896 356,201 356,506 356,812 357,117 357,422 357,422 357,727 358,031 358,336 358,641 358,945 359,249 359,553 359,857 360,161 360,465 360,465 360,769 361,073 361,376 361,679 361,983 362,286 362,589 362,892 363,194 363,497 363,497 363,800 364,102 364,404 364,707 365,009 365,311 365,613 365,914 366,216 366,517 366,517 366,819 367,120 367,421 367,722 368,023 368,324 368,625 368,925 369,226 369,526 369,526 369,826 370,127 370,427 370,726 371,026 371,326 371,625 371,925 372,224 372,523 372,523 372,822 373,121 373,420 373,719 374,017 374,316 374,614 374,913 375,211 375,509 375,509 375,807 376,105 376,402 376,700 376,997 377,295 377,592 377,889 378,186 378,483

ITERNATIONAL THERMOCOUPLE CABLES COLOR CODING


TEMPERATURE RANGE (C)

IEC 584-3
(Europe)

ANSI
(USA,Canada)

DIN43710
(German Holland)

BS1843
(U.K- Cecoslovacchia)

NFE 18001
(France)

JIS 1610-1981
(Japan)

T
Copper + Copper-Nikel -

-270/+400

J
Iron + Copper-Nikel -

-200/+760

E
Nikel-Cromium + Coppe-Nikel -

-270/+1000

K
Nikel-Cromium + Nikel-Alluminium -

-270 /+1372

N
-270 /+1300
Nikel-Cromium-Silica +
Nijel-Silica-Manganesia -

S&R
Platinum-Rho. + Platinum -

-50/+1768

B
Platinum 30%-Rho. +

0/+1820

Platinum -

LA TERMOTECNICA
Thermocouples - RTD s Laboratory instrumentation

Electric heaters Calibration center

Anda mungkin juga menyukai