Anda di halaman 1dari 6

Tailor Made Concrete Structures Walraven & Stoelhorst (eds) 2008 Taylor & Francis Group, London, ISBN

BN 978-0-415-47535-8

Properties and applications of DUCON A micro-reinforced ultra-high-performance concrete


Jens Schneider & Jrg Reymendt
Frankfurt University of Applied Sciences, Department of Architecture and Civil Engineering, Frankfurt, Germany

ABSTRACT: The main advantage of DUCON (DUctile CONcrete), a patented 3-D micro-reinforced, selfcompacting Ultra High Performance Concrete, is its ductility in combination with high compressive and flexural strength. This paper describes the properties and recent applications of DUCON. The material proved to have exceptional advantages as explosion resistant and bullet/fragment proof material. Explosion tests performed showed high energy absorption and ductility, i.e. no failure and no fragment projectiles. Special sniper projectiles which easily penetrate standard reinforced concrete can be stopped by DUCON panels. The main field of applications and projects realized so far are therefore the protection of critical infrastructure, such as military and public buildings, embassies, power plants, banks and data centers and ammunition storage tanks. Here, DUCON is used in new structures or for retro-fitting of existing structures in slabs and walls (fragmentation protection), for column protection, protective elements, etc. Moreover, other engineering and architectural projects realized such as industrial overlay, retro-fitting of columns for earthquake protection, slim faade panels and interior design elements show the great variety in applications of the material.

1 1.1

MATERIAL Composition and material characteristics

6 mm and 35 mm) which are 3-dimensionally connected. Table 1 shows the most important material characteristics. 1.2 Production Production is based on the placement of the prefabricated micro-reinforcement and the infiltration of the concrete slurry (Fig. 2). Between 1 Vol.-% and 10 Vol.-% of microreinforcement are embedded, typically, 6 Vol.-%. Due to the fine mesh size of the microreinforcement, the crack width can be reduced to values of w < 0,1 mm which qualifies DUCON as
Table 1. Type Compressive strength Flexural strength Tensile strength Shear strength Modulus of elasticity Thickness Ductility factor Material characteristics. Value 90180 N/mm2 (cube) 1675 N/mm2 920 N/mm2 316 N/mm2 >35,000 N/mm2 10 mm500 mm >10

DUCON stands for DUctile CONcrete and represents the combination of a high-performance or ultra-highperformance concrete and a micro-reinforcement from steel wire meshes (Fig. 1), developed by Hauser. The micro-reinforcement is uniformly distributed all over the cross section which results in a homogenous composition of the composite material (Hauser 1999, Hauser & Wrner 1999). It consists of multiple layers of meshes with variable mesh width (between

Figure 1. Self-compacting micro-reinforcement.

high-strength

concrete +

399

Figure 2. Slurry infiltration process.

Figure 4. Four-Point-Bending-Test of a DUCON member, thickness 25 mm.

Flexural strength DUCON ductile Stress-Strain-Curve


80 70 60 50 40 30 20 10

K6

Flexural Stress [N/mm]

DUCON

ECC Standard Concrete

5% Deflection [Strain]

Figure 3. Stress-deflection diagram for three different adjustments A, B, C of DUCON in comparison with standard concrete and a typical fiber-reinforced concrete.

Figure 5. Comparison of DUCON (blue) with an Engineered Cementitious Material (ECC, green) and standard concrete (black).

impervious material. Thus, DUCON can be executed with a small concrete cover of a few millimeters compared to 20 to 50 mm of standard reinforced concrete. 1.3 Flexural strength and ductility

One major benefit of DUCON is that the material performance is programmable. Various set-ups and qualities of the micro-reinforcement (e.g. steel characteristics) allow the adaption of the material performance to the specific application. Figure 3 shows a stress-deflection diagram from flexural bending strength tests (Fig. 4) with three different possible adjustments A, B, C in comparison with standard concrete and typical fiber-reinforced concrete. Note that the curves for standard concrete (grey) and fiberreinforced concrete (blue) are shifted horizontally for a better legibility. Besides having high compressive and flexural strength, the properties can thus be adjusted to achieve an extremely ductile material.The ductility and its high strength are the key characteristics for high energy absorption of high speed dynamics and dynamics in combination with large deformations.

Compared to other ductile materials DUCON provides a high load bearing capacity at the same time (Fig. 4). The specimen as shown in Fig. 4 had a maximum deflection at a failure of 75 mm at 540 mm span. These characteristics are required for building protection for example against explosion and earthquake. Figure 5 shows a comparison of the flexural behavior of DUCON in comparison with a typical Engineered Cementitious Composite (ECC, Wang & Li 2006) and a standard concrete. Whereas ECC has approximately half the flexural strength of Ductal (another ultra-high-performance concrete) but 20 times its tensile ductility (Smock, 2007), DUCON exhibits even more than twice the tensile ductility of ECC and more than 4 times its flexural strength. 2 DYNAMIC PROPERTIES

2.1 Blast resistance Figures 6 and 7 demonstrate the resistance of DUCON against close range and contact charges compared to reinforced concrete (RFC) at the same thickness of

400

RFC

Figure 6. Reinforced concrete fails under contact charge. Full penetration + fragment projectiles.

Figure 9. DUCON panel, thickness 100 mm, resists a armor piercing Wolfram-Carbit Penetrator at a speed of 840 m/s.

2.2 Ballistic resistance According to the blast resistance DUCON proved a comparable performance in ballistic resistance. It reaches the resistance of reinforced concrete with less than 50% of the thickness. Moreover, the special 3-dimensional micro-reinforcement allows a structural integrity of the concrete and avoids spalling. Figure 9 shows that a 100 mm thick DUCON panel absorbed armor piercing bullet (Wolfram-Carbit penetrator at a speed of 840 m/s) while RFC needed to be 24 cm. Bullet tests resulted in a PM7 (highest requirement level of European code) for a thickness of only 80 mm. Further Military test series (Marchand 2007) proved that a 10 cm DUCON-panel also resists high velocity fragments of propeller drilled weapons, like Mortars in combination with explosion. 3 150 mm (RTL TV broadcasting, 2004). The reinforced concrete failed, the blast wave penetrated the panel and in addition created fragment projectiles. DUCON resisted the blast test and no penetration or fragments could be observed. Several blast tests of the Fraunhofer Institute and for the US Military (Schuler & Mayrhofer 2004, Schuler & Mayrhofer 2007, Marchand 2007) proved that the blast resistance of DUCON is at least twice as good as of ordinary reinforced concrete, which means it can be executed at half the thickness and in addition it does not spall. The 3-dimensional micro-reinforcement keeps the structural integrity of the concrete and avoids spalling and fragment projectiles. The material properties of DUCON have been recently implemented into a finite element code for high-speed dynamics (Fig. 8, Gebbeken & Greulich, 2006). RECENT APPLICATIONS

DUCON

Figure 7. DUCON remains stable, no penetration nor fragment projectiles, 85% of the cross section stays intact.

Figure 8. Finite-element simulation of DUCON under contact charge load.

3.1 Fragmentation protection for blast loading Figure 10 shows an application of a DUCON layer (thickness 15 mm) acting as an integrated safety-net on the bottom of a reinforced concrete slab (thickness 300 mm). The tests performed proved the effectiveness of DUCON to remain the structural integrity of the slab under blast loading. This application has been used several times to protect the server room of high security data centers in Europe. It was also used for the concrete walls. 3.2 Blast protection wall and blast protection facade In these applications, DUCON has been used as protective walls and secondary facades in front of endangered buildings. Walls have a typical thickness of 100 mm to 250 mm, faade elements a typical

401

RFC

DU CON

Figure 10. DUCON panel, thickness 15 mm, acts as an integrated safety-net on the bottom of a reinforced concrete slab. Figure 12. Retro-fitting of existing columns for earthquake protection.

Figure 11. DUCON wall, thickness 250 mm, acts as protective element in front of an embassy.

Figure 13. DUCON tubes used as integrated formwork for reinforced concrete columns.

thickness of 40 mm to 150 mm. The DUCON panels are prefabricated elements and can be easily transported and installed. Figure 11 shows an embassy in Europe protected by a DUCON wall. 3.3 Blast protection columns

Here, two types of production have been applied; a retro-fitting of existing columns (Fig. 12) or tube columns made of DUCON used as integrated formwork (Fig. 13). They have been applied for earthquake protection (Zekaria 2001) and for blast protection (Schuler & Mayrhofer 2007). 3.4 Impervious and abrasive resistant overlays
Figure 14. DUCON overlay, 25 mm, applied on an existing cracked concrete slab of a chemical plant.

Based on the high performance material characteristics of DUCON, impermeability, durability, freeze-thaw resistance and corrosion resistance in combination with crack control have been tested for the International Code Council (ICC) approval which was obtained for the applications on the US market.

These characteristics are well suited for applications of thin impervious overlay on top of existing or damaged flooring or concrete structures. Figure 14 shows an application at a chemical plant where 7.500 m2 of damaged and cracked concrete

402

REFERENCES
Blastow M. 2006. High performance product testing goes ballistic, Concrete Products, 10/2007: 3639. Gebbeken, N. & Greulich, S. 2005. Expert opinion and structural design of blast wall, Universitt der Bundeswehr, report. Gebbeken, N. & Greulich, S. 2006. Expert opinion on structural design of a blast wall, Universitt der Bundeswehr, report. Hauser S. 1999. DUCON und SIMCON NEU ein innovativer Hochleistungsbeton, PhD-thesis, Darmstadt University of Technology. Hauser, S. & Wrner J.-D. 1999. DUCON ein innovativer Hochleistungsbeton Teil 1: Grundlagen. Beton- und Stahlbetonbau, 2/1999: 6675. Hauser, S. & Wrner J.-D. 1999. DUCON ein innovativer Hochleistungsbeton Teil 2: Bemessung. Beton- und Stahlbetonbau, 3/1999: 141145. Hauser, S. & Wrner J.-D. 1999. Hochleistungsfaserbeton, Materialeigenschaften und Anwendungen, In Festschrift zum 60. Geburtstag von Herrn Prof. Falkner, TU Braunschweig, 1999. Hauser, S. & Wrner J.-D. 1999 DUCON, a durable overlay, Rilem HPFRCC International Symposium Mainz, May 1999. Hofmann, P. et al. 2007. Toughened throughout. Microreinforced concrete gets blast resistance as its first assignment, Concrete International 29(12). Marchand, K. 2007. Ballistic and Blast Tests of DUCON Panles for Department of Defense at deployed operation bases (DOBs) Overhead Cover Applications. Protection Engineering Consultants, report, July 12th, 2007. Miller, S. 2007. Explosion in blast resistant construction, Masonry Construction Journal, 10/2007: 15. Reymendt, J. 2006. Instandsetzung von Betonbauteilen beim Umgang mit wassergefhrdeten Stoffen. In: Dehn F., Klaus Holschemacher, K., Tue, N.V . (eds). Sanierung und Verstrkung von Massivbauten. Bauwerk Verlag GmbH, Berlin. RTL TV broadcasting 2004. Blast tests DUCON vs. RFC Seminar of THW and Firemen. Schuler H. & Mayrhofer C. 2004. Storohrprfung von Platten aus DUCON, Fraunhofer Ernst Mach Institute, August 2004. Schuler H. & Mayrhofer C. 2007. Untersuchung von mikrobewehrten Betonsttzen bei Explosionseinwirkungen, Fraunhofer Ernst Mach Institute, Report, June 2007. Smock, D. 2007. Bendable Concrete Protects Against Hurricanes. Reed Business Information, Reed Elsevier, November 11th, 2007. Wang, S & Li, V .C. 2006. High-Early-Strength Engineered Cementitious Composites. ACI Material Journal, MarchApril 2006: 97105. Zekaria, A. 2001. Seismic retrofitting of reinforced concrete columns using SIMCON jackets, PhD-thesis, Darmstadt University of Technology.

Figure 15. Entrance portal of DUCON, height 4,50 m, span 4,50 m, thickness 80 mm to 100 mm.

slab could be quickly repaired by a 25 mm DUCON overlay and a time- and cost consuming demolition and reconstruction of the concrete could be avoided. 3.5 Architectural applications Beside thin plates for tables, faade panels or counter tops, recently also structural elements have been produced. Figure 15 shows an application as an entrance portal, height 4,50 m, span 4,50 m with a thickness of only 80 mm to 100 mm. The portal was pre-fabricated and installed on site. Thin members of concrete for free-form applications are another future possibility as the microreinforcement can be adapted to any shape by hand.

CONCLUSIONS

DUCON, a very ductile composite material of concrete and steel, shows excellent material properties and a large spectrum of applications. Its high energy absorption allows applications for blast and ballistic protection without fragmentation at approximately half the thickness of ordinary reinforced concrete. Future applications and research should also consider the stability behavior of the material, e.g. for shells and thin membranes and should develop new connections. DUCON = registered Trademark of DUCON GmbH.

403

Anda mungkin juga menyukai