Anda di halaman 1dari 11

15

ax m s o Is CB MC
K1S4

Electrical accessories Shunt trip, undervoltage release S1


Shunt trip
Voltage Factory installation Catalog number sufx 1 List price adder Field installation 2 Catalog number S1 List price

For remote opening of circuit breaker and includes internal cut-off switch to protect solenoid. All shunt trips are left pole mounted and can not be used with undervoltage releases. All shunt trips are approved for use in ground fault systems. Shunt trips must be ordered with correct connector.

48VAC/60VDC 220/250VAC 24 30VAC 110 130VAC 250VDC 110VDC 48VDC 24VDC 220VDC

S1 S2 S3 S4 S5 S6 S7 S8 S9

$ 212

K1S1 K1S2 K1S3 K1S4 K1S5 K1S6 K1S7 K1S8 K1S9

$ 197

Shunt trip connectors


Type Voltage

Factory installation

Field installation 2 Catalog number S1 List price

Fixed mounted Electrical specications V

All

Included

K2C-SU

$ 15

For S1 P
S1 with K1S4

24, 120, 240, 480VAC ~ 50/60 Hz 24, 48, 125, 250VDC 100VA~/120W Instananeous duty

Undervoltage releases (IEC)


Voltage

Factory installation Catalog number sufx 1 List price adder

Field installation 2 Catalog number S1

15

Will trip circuit breaker when connected voltage drops to 35 70% of undervoltage release voltage rating. Will allow circuit breaker to close (ON) when voltage is approximately 85% of rated voltage. All undervoltage releases are left pole mounted and can not be used with shunt trips. Undervoltage releases must be ordered with correct connector.

380/400VAC 220/230VAC 24VAC 110VAC 110VDC 48VDC 24VDC 48VAC

U1 U2 U3 U4 U6 U7 U8 U9

$ 212

K2U1 K2U2 K2U3 K2U4 K2U6 K2U7 K2U8 K2U9

Price

List

$ 197

Undervoltage release connectors


K2U1 Type Voltage Factory installation

Field kit 2 Catalog number S1 List Price

Fixed mounted Electrical specications V For S1 P

All

Included

K2C-SU

$ 15

24, 120, 240, 480VAC ~ 50/60 Hz 24, 48, 125, 250VDC 6VA~/3W Continuous duty

1 For factory installation add sufx given to end of circuit breaker catalog number per accessory format. 2 Not UL approved for eld installation.

15.54
AC 1000 - 11/03

Discount schedule SA

Low Voltage Products & Systems


ABB Inc. 888-385-1221 www.abb-control.com

Spec Tech Industrial 203 Vest Ave. Valley Park, MO 63088 Phone: 888 SPECTECH Fax: 636 537-1405 www.spectechind.com

Electrical accessories Shunt trip, undervoltage release S3 S7


Shunt trips
Factory installation Voltage Catalog number sufx 1 List price adder Field installation Catalog numbers S3 S4 S5 S6 S7

15
Is MC oma CB x s
List price

480VAC/250VDC 240VAC 120VAC/125VDC 48VDC 24VAC/VDC 12VDC


K5S1

S1 S2 S4 S7 S8 S9

$ 430

K5S1 K5S2 K5S4 K5S7 K5S8 K5S9

K7S1 K7S2 K7S4 K7S7 K7S8 K7S9

$ 415

Low power shunt trips


Factory installation Voltage Catalog number sufx 1 List price adder Field installation Catalog numbers S3 S4 S5 S6 S7 List price

24VDC 120VAC

SA SB

$ 430

K5SA K5SB

K7SA K7SB

$ 415

For remote opening of circuit breaker and includes internal cut-off switch to protect solenoid. All shunt trips are left pole mounted and can not be used with UVRs. Except for 12VDC, all shunt trips are approved for use in GF systems. Shunt trips must be ordered with correct connector.

Shunt trip connectors (required)


Type circuit breaker S5 with K5S2 Voltage Factory installation 1 Field kit catalog number S3 S4 S5 S6 S7 List price

Fixed mounted Plug-in/Draw-out

All All

included included

K6C-SU K6C-SUP

K7C-SU K7C-SUP

$ 15

Electrical specications shunt trips (standard) V For S3-S5 P For S6-S7 24, 120, 240, 480VAC ~ 50/60 Hz 12, 24, 48, 125, 250 VDC 100 VA~/120W Instantaneous duty 150 VA~/150W

Undervoltage releases
Factory installation K5U1 Voltage Catalog number sufx 1 List price adder Field installation Catalog numbers S3 S4 S5 S6 S7 List price

15

480VAC 240VAC 120VAC 24VAC 250VDC 125VDC 48VDC 24VDC


K6C-SUP

U1 U2 U4 U3 U5 U6 U7 U8

$ 430

K5U1 K5U2 K5U4 K5U3 K5U5 K5U6 K5U7 K5U8

K7U1 K7U2 K7U4 K7U3 K7U5 K7U6 K7U7 K7U8

$ 415

Will trip CB when connected voltage drops to 35-70% of UVR voltage rating. Will allow CB to close (ON) when voltage is approximately 85% of rated voltage. All UVRs are left pole mounted and can not be used with shunt trips. UVRs must be ordered with correct connector.

Undervoltage release connectors (required)


Type circuit breaker Voltage Factory 1 installation Field kit catalog number S3 S4 S5 S6 S7 List price

Fixed mounted Plug-in/Draw-out

All All

included included

K6C-SU K6C-SUP

K7C-SU K7C-SUP

$ 15

Electrical specications UVR & low power shunt trips V For S3-S5 P For S6-S7 24, 120, 240, 480 VAC ~ 50/60 Hz 24, 48, 125, 250 VDC 6 VA~/3W Continuous duty 10 VA~/4W

1 For factory installation add sufx given to end of circuit breaker catalog number per accessory format.

Low Voltage Products & Systems


ABB Inc. 888-385-1221 www.abb-control.com

Discount schedule SA

15.55
AC 1000 - 11/03

15
ax m s o Is CB MC
S1 with auxiliaries

Electrical accessories Auxiliary contacts S1 S7


Auxiliary contacts S1
Factory install Contacts Catalog number sufx 1 List price adder Field installation 2 Catalog number S1 List price

2 Form Cs 1 BA & 1 C

A BA

$ 190

K1AS K1BA

$ 175

The auxiliary contacts are accessory contacts for the indication of circuit breaker open-closed or tripped. Bell alarm contacts (B.A.) can be used to indicate circuit breaker tripping. All contacts are right pole mounted

Auxiliary contact connectors S1


Field installation 2 Type Voltage Factory installation Catalog number S1 List price

Fixed mounted Electrical specications S1


Voltage

All

Included

K2C-AB

$ 15

Maximum contact amperage rating

30 VDC 127 VDC 220 VAC N.O. = contact is open as circuit breaker is open N.C. = contact is closed when circuit breaker is open B.A. = will open/close only when circuit breaker trips

4A 4A 4A

K5AS

Auxiliary contacts S3 S7
Factory installation Contacts Catalog number sufx 1 List price adder S3 S4 S5 Field installation Catalog numbers S6 S7 List price

2 Form Cs 1 BA & 1 C 1 B BA & 1A + 1B

A BA BA3

$ 275 365

K5AS K5BA

K7AS K7BA K7BA-3

$ 260 350

The auxiliary contacts are accessory contacts for the indication of circuit breaker open-closed or tripped. Bell alarm contacts (B.A.) can be used to indicate circuit breaker tripping. All contacts are right pole mounted.
K6C-ABP

Auxiliary contact connectors (required) S3 S7


Type circuit breaker Voltage Factory installation1 Field kit catalog number S3 S4 - S5 S6 S7 List price

15

Fixed mounted Plug-in/Draw-out Electrical specications


Voltage

All All

included included

K6C-AB K6C-ABP

K7C-AB K7C-ABP

$ 15

Maximum contact amperage rating

125 VDC 250 VDC 250 VAC N.O. = contact is open as circuit breaker is open N.C. = contact is closed when circuit breaker is open B.A. = will open/close only when circuit breaker trips

0.3 A 0.15 A 6A

S5 with K6C-AB

1 For factory installation add sufx given to end of circuit breaker catalog number per accessory format. 2 Not UL approved for eld installation.

15.56
AC 1000 - 11/03

Discount schedule SA

Low Voltage Products & Systems


ABB Inc. 888-385-1221 www.abb-control.com

Electrical accessories Motor operators, stored energy motor operators S3 S7


Motor operator
Voltage

15
Is MC oma CB x s
Catalog number S3 S4 S5 List price

240VAC/250VDC 120VAC/125VDC 48VDC 24VDC

K5M2 K5M4 K5M7 K5M8

$ 678

K5M2

For remote control of circuit breaker opening and closing. Complete with manual operating lever, padlock device and emergency opening push-button. When ordering the connector always specify type and version of the circuit-breaker. The following options are also available: key lock for open position key lock for open position of two or more circuit breakers (using the same key for groups of circuit breakers)

Motor operator connectors (required)


Type circuit breaker Voltage Field kit catalog number S3 S4 S5 List price

Fixed mounted Plug-in/Draw-out Electrical specications V


S4 with K5M2

All All

K6C-M K6C-MP

$ 15

120, 240VAC ~ 50/60 Hz 24, 48, 125, 250 VDC 500 VA~/500W 350 VA~/500W 0.1 s 0.1 s

P inrush P normal Close time Open time

Stored-energy motor operator


Catalog number K6C-M Voltage S6 S7 List price

240VAC/250VDC 120VAC/125VDC 48VDC 24VDC

K6M2 K6M4 K6M7 K6M8

K7M2 K7M4 K7M7 K7M8

$ 2407

Stored-energy motor operator with springs automatically pre-loaded by motor. Complete with shunt opening and closing release, and compartment door ange. When ordering the connector always specify type and version of the circuit-breaker. The following options are also available: key lock for open position key lock for open position of two or more circuit-breakers (using the same key for groups of circuit-breakers).

15

Stored-energy motor operator connectors (required)


Type circuit breaker Field kit catalog number Voltage S6 S7 List price

Fixed mounted Plug-in/Draw-out


K6M2

All All

K6C-M K6C-MP

K7C-M K7C-MP

$ 15

Electrical specications V P inrush P normal Close time Open time Reset time 120, 240 VAC ~ 50/60 Hz 24, 48, 125, 250 VDC 660 VA~/600W 180 VA~/180W 0.09 s 1.2 s 2.0 s

S7 with K7M4

Low Voltage Products & Systems


ABB Inc. 888-385-1221 www.abb-control.com

Discount schedule SA

15.57
AC 1000 - 11/03

15
ax m s o Is CB MC
K4TB

External accessories Lugs and termination kits S3 S7


Standard cable lug kits
For breakers Amps1 Wire range Set of 2 catalog number List price Set of 3 catalog number List price

S3 S3 S4 S3 S4 S3 S4 S5 S4 S5 S5 S6 S6 S7

60 100 150 225 250 300 400 600 800 1200

14AWG 14AWG 2AWG 4AWG 6AWG 250kcmil (2) 3/0 (2) 250kcmil (3) 2/0 (4) 4/0

2AWG 1/0 4/0 300kcmil 350kcmil 500kcmil 250kcmil 500kcmil 400kcmil 500kcmil

K3TA-2 K4TB-2 K4TC-2 K4TD-2 K4TE-2 K5TF-2 K5TG-22 K6TH-2 K6TJ-22 K7TK-2

$4 4 4 10 20 30 30 50 90 120

K3TA K4TB K4TC K4TD K4TE K5TF K5TG2 K6TH K6TJ2 K7TK

$6 6 6 15 30 45 45 75 135 180

Standard cable lugs, for use on line and load side of circuit breaker. Suitable for use with Cu or Al. Special versions available with taps and screws for control wire connection. Note: S6 and S7 lugs are Al9Cu (90C); all others Al7Cu (75C).

Standard cable lug kits with control power taps


For breakers Amps1 Wire range Set of 2 catalog number List price Set of 3 catalog number List price

K4ET-250

S3 S4 S3 S4 S3 S4 S5 S4 S5 S5 S6 S6 S7

100 150 225 250 300 400 600 800 1200

14AWG 2AWG 4AWG 6AWG 250kcmil (2) 3/0 (2) 250kcmil (3) 2/0 (4) 4/0

1/0 4/0 300kcmil 350kcmil 500kcmil 250kcmil 500kcmil 400kcmil 500kcmil

K4TB-2C K4TC-2C K4TD-2C K4TE-2C K5TF-2C K5TG-2C2 K6TH-2C K6TJ-2C2 K7TK-2C

$8 8 14 24 34 34 54 94 124

K4TBC K4TCC K4TDC K4TEC K5TFC K5TGC2 K6THC K6TJC2 K7TKC

$ 12 12 21 36 51 51 81 141 186

Extended front termination kits


K4TES Suitable for use with Maximum amps Set of 6 catalog number List price

S3 S4 S5 S6 S6 S7

250 400 630 800 1250

K4ET-250 K5ET-400 K6ET-600 K6ET-800 K7ET-1250

$ 46 114 150 170 240

For adding onto standard circuit breaker front terminals, extending available connection area for user termination. Suitable for spaded cable or bus connection. S3 S5 include terminal covers.

15
K4TER

Saddle cable lug kits (Cu cable only)


Suitable for use with Max amps Wire range Set of 6 catalog number List price

S3 S4 250 14AWG 250kcmil K4TES $ 30 S5 400 250kcmil 500kcmil K5TGS 90 These special non-aluminum cable lugs are for use with copper cable. Lugs are intended for use with copper cable or where non-aluminum connectors are required (marine, salt or corrosive environments).

Rear cable lug kits (Cu cable only)


Suitable for use with Max amps Wire range Set of 6 catalog number List price

S3 S4 S5 S6 S6

250 400 600 800

6AWG 250kcmil 250kcmil 500kcmil (2) 2/0 350kcmil (3) 250kcmil 350kcmil

K4TER K5TGR K6THR K6TJR

$ 30 90 150 170

For use where cable connection from the back-rear of the breaker is desired.

Distribution cable lug kit


K4TN Suitable for use with Max amps Wire range Set of 3 catalog number List price

S3 S4 S5

250 400

(6) #14 - 6 (6) #14 - 1/0

K4TN K5TGD

$ 125 240

1 Suggested lugs for circuit breaker up to amps shown. Cable size and type determine maximum amperes. 2 Includes required lug covers.

15.58
AC 1000 - 11/03

Discount schedule SA

Low Voltage Products & Systems


ABB Inc. 888-385-1221 www.abb-control.com

External accessories Rotary and variable depth handle operators S1 S7


Rotary handle operating mechanism
Frame Catalog number

15
Is MC oma CB x s
List price

S3 S4 S5 S6 S7

K5RH K6RH K7RH

$ 108 124 145

Mounts directly onto breaker. Includes door interlock to prevent CB door opening while CB is in ON position. Padlock provision included to padlock CB in open position. Can also be key locked with optional cylinder lock assembly. Door interlock bracket must be ordered separately, if required. See page 15.62.
K5RH

Variable depth rotary handles


New pistol type 1, 3R, 12
Frame Catalog number mechanism List price Shaft catalog number (length in inches) List price Handle catalog number (length in inches) List price

S1

K2VD-M

$ 59 OXP10X148 (5.8) OXP10X225 (8.9) OXP10X500 (19.7) $ 24 26 32

OHB45J10 OHG45J10 OHB65J10 OHG65J10 OHB95J10 OHG95J10 OHB125J10 OHG125J10 OHB175J10 OHG175J10

(1.8) (1.8) (2.6) (2.6) (3.7) (3.7) (4.9) (4.9) (6.9) (6.9)

$ 70

OHB65J10

S3S4S5 K5VD-M S6 S7 K6VD-M K7VD-M

49 80 80

80 90 100

Pistol type 4, 4X
OHB95J10 Frame Catalog number mechanism List price Shaft catalog number (length in inches) List price Handle catalog number (length in inches) List price

S1

K2VD-M

$ 59 OXP10X148 (5.8) OXP10X225 (8.9) OXP10X500 (19.7) $ 24 26 32

OHB45L10 OHG45L10 OHB65L10 OHG65L10 OHB95L10 OHG95L10 OHB125L10 OHG125L10 OHB175L10 OHG175L10

(1.8) (1.8) (2.6) (2.6) (3.7) (3.7) (4.9) (4.9) (6.9) (6.9)

$ 110

S3S4S5 K5VD-M
OHB125J10

49 80 80

120 130 140

S6 S7

K6VD-M K7VD-M

Square type 1 S1 K2VD-M S3S4S5 K5VD-M S6 K6VD-M S7 K7VD-M

$ 59 49 80 80

K5VD-S12 K7VD-S20

$ 24 27

K2VD-H K5VD-H K7VD-H K7VD-H

$ 25 25 28 28

15

NOTE: Complete assembly requires a mechanism, shaft and handle.

Variable depth shaft support


K5VD-M, K5VD-S12, K5VD-H For frames Catalog number List price

S3 S4 S5

K5VD-LSS

$ 25

New pistol handle catalog number explanation OHB 125 J 10


Shaft size (diameter in mm) J = Type 1, 3R, 12 L = Type 1, 3R, 4, 4X, 12 Physical size (length in mm) Color B = black G = gray Y = yellow / red

Low Voltage Products & Systems


ABB Inc. 888-385-1221 www.abb-control.com

Discount schedule SH

15.59
AC 1000 - 11/03

15
ax m s o Is CB MC

External accessories Flange handle operators S1 S6


Flange handle Solid shaft linkage
Breaker NEMA type Complete handle kit List price Mechanism only List price Shaft only Shaft length List price Handle only List price

S1

K2FHD-12S12 1,3R,12 K2FHD-17S12 K2FHD-22S12 4, 4X K2FHD-12S4 K2FHD-17S4 K2FHD-22S4

$ 240 248 255 280 288 295 240 248 255 280 288 295 240 248 255 280 288 295 240 248 255 280 288 295 523 531 538 563 571 578

K2FHD-M

$ 128

K7FHD-S12 K7FHD-S17 K7FHD-S22 K7FHD-S12 K7FHD-S17 K7FHD-S22 K7FHD-S12 K7FHD-S17 K7FHD-S22 K7FHD-S12 K7FHD-S17 K7FHD-S22 K7FHD-S12 K7FHD-S17 K7FHD-S22 K7FHD-S12 K7FHD-S17 K7FHD-S22 K7FHD-S12 K7FHD-S17 K7FHD-S22 K7FHD-S12 K7FHD-S17 K7FHD-S22 K7FHD-S12 K7FHD-S17 K7FHD-S22 K7FHD-S12 K7FHD-S17 K7FHD-S22

12 17 22.5 12 17 22.5 12 17 22.5 12 17 22.5 12 17 22.5 12 17 22.5 12 17 22.5 12 17 22.5 12 17 22.5 12 17 22.5

$ 19 27 34 19 27 34 19 27 34 19 27 34 19 27 34 19 27 34 19 27 34 19 27 34 19 27 34 19 27 34

K7FHD-HS12

$ 93

K7FHD-HS4

133

S3

K3FHD-12S12 1,3R,12 K3FHD-17S12 K3FHD-22S12 4, 4X K3FHD-12S4 K3FHD-17S4 K3FHD-22S4

K7FHD-HS12

93

K3FHD-M

128

K7FHD-HS4

133

S4

K4FHD-12S12 1,3R,12 K4FHD-17S12 K4FHD-22S12 4, 4X K4FHD-12S4 K4FHD-17S4 K4FHD-22S4

K7FHD-HS12

93

K4FHD-M

128

K7FHD-HS4

133

K7FHD-HS12

S5

K5FHD-12S12 1,3R,12 K5FHD-17S12 K5FHD-22S12 4, 4X K5FHD-12S4 K5FHD-17S4 K5FHD-22S4

K7FHD-HS12

93

K5FHD-M

128

K7FHD-HS4

133

S6

K6FHD-12S12 1,3R,12 K6FHD-17S12 K6FHD-22S12 4, 4X K6FHD-12S4 K6FHD-17S4 K6FHD-22S4

K7FHD-HS12

93

K6FHD-M

411

K7FHD-HS4

133

Available as complete kits including ange handle, shaft and breaker operating mechanism. Mechanism mounts directly onto breaker and shaft can be cut to the desired length for the breaker enclosure. Door is interlocked with the handle when the breaker is in the closed (ON) position; handles include interlock defeater for emergency override. Handle can be padlocked in the open (OFF) position. Can be eld converted for left hand mounting.

Door hardware kits Solid shaft linkage & S1 - S2 Cable operated

15

Item

Catalog number

List price

Door hardware kit, right hand, 2 point latch for enclosures less than 40 inches high Roller for 3 point latch, add to FH-DHK

FH-DHK FH-3RL

$ 150 30

Enclosure depths
Minimum
Breaker Depth (inches)

S1 S3 - S5 S6 Maximum
For maximum depth, add 4 inches to the shaft length

8 10 11

1 Cable not included.

15.60
AC 1000 - 11/03

Discount schedule SH

Low Voltage Products & Systems


ABB Inc. 888-385-1221 www.abb-control.com

External accessories Flange handle operators S1 S7


Flange handle Cable linkage
Breaker NEMA type Mechanism only List price Cable only Cable length List price Handle only

15
Is MC oma CB x s
List price

1,3R,12 S1 4, 4X 1,3R,12 S3-S4 4, 4X 1,3R,12 S5 4, 4X 1,3R,12 S6 4, 4X 1,3R,12 S7 4, 4X


K7FCH

K2FHDC-M K2FHDC-M K4FPM K4FPM K5FPM K5FPM K6FPM K6FPM K7FPM K7FPM

$ 198 198 110 110 128 128 220 220 220 220

K6FHDC-036 K6FHDC-060 K6FHDC-036 K6FHDC-060 K5C036 K5C048 K5C060 K5C072 K5C084 K5C096 K5C108 K5C120 K7C048 K7C060 K7C072 K7C084 K70096 K7C120

36(91cm) 60(152cm) 36(91cm) 60(152cm) 36 (91cm) 48 (122cm) 60 (152cm) 72 (183cm) 84 (213cm) 96 (244cm) 108" (274cm) 120" (305cm) 48 (122cm) 60 (152cm) 72 (183cm) 84 (213cm) 96 (244cm) 120 (305cm)

$ 114 146 114 146 114 146 160 175 204 221 238 256 190 220 256 270 320 350

K7FHD-HS12 K7FHD-HS4 K5FCH K5FCH4 K5FCH K5FCH4 K7FCH K7FCH4 K7FCH K7FCH4

$ 93 133 213 243 213 243 310 415 310 415

Notes: For complete assembly; mechanism, cable and handle are required. All cables mount onto the right side of the breaker. Handle can be mounted on the right or left side.

Door hardware kits S3 - S7 Cable operated


Item Catalog number List price

Door hardware kit, right hand, 2 point latch for enclosures less than 40 inches high Door hardware kit, right hand, 3 point latch for enclosures 40 inches high or greater

KDH2R KDH3R

$ 200 225

Enclosure depths
Minimum
Breaker Depth (inches)

S1 - S6 S7 Maximum
Maximum depth is determined by cable length.

8 10

15

Low Voltage Products & Systems


ABB Inc. 888-385-1221 www.abb-control.com

Discount schedule SH

15.61
AC 1000 - 11/03

15
ax m s o Is CB MC
K5LD

External accessories S1 S7
Front locking device
Item Catalog number List price

S1 S3 S4 S5 S6 S7 S3 S4 S5 S6 S7

K1LD K5LD K6LD K7LD K5LDW 1 K6LDW 1 K7LDW 1

$ 14 14 16 20 14 16 20

Mounts directly onto front of CB. Includes padlock device for locking CB in open position. Can be used as a manual handle block, with padlock or with optional key lock accessory. Optional door interlock kit that will prevent CB door from opening while CB is in the closed (ON) position.

Door interlock bracket


Item Catalog number S3 S7 List price

Bracket

K7DB

$5

Key locks
Catalog number Accessory Keys S3 S4 S5 S6 S7 List price

Electric operator
K7KL

different same different same

K5KL-EO K5KL-EO-2 K7KL K7KL-2

K7KL-EO K7KL-EO-2 K7KL K7KL-2

$ 25

Rotary HM & locking device

Keyed cylinder locks are available for mounting onto Isomax electric operators, rotary handle mechanisms and front locking devices. Key locks can be for one individual circuit breaker (different keys in each order) or for two circuit breakers using the same key.

Terminal covers for xed circuit breakers


K6LC Frame Low prole catalog number List price High prole catalog number List price

S1 S3 S4 S5 S6 S7

K1LC K4LC K5LC K6LC K7LC

$8 8 12 18 40

K1LCH K4LCH K5LCH K6LCH

$ 16 16 24 32

Both high and low types are available for xed circuit-breakers. Covers provide IP40 degree of protection for xed mounted circuit breakers. Lug covers are required and included as standard with S5 400A and S6 800A cable lug kits. Covers up to S6 can be sealed with lug cover seal shown in next section.

15
K6LCH

Terminal cover seals


Suitable for use with breakers Used with LC covers List price

S3 S4 S5 S6 These screws prevent the terminal covers from being removed.

K6LC-S

$5

DIN rail mounting kits


Suitable for use with breakers Catalog number List price

K6LC-S

S1 S3 S4 S5

K1DMB K3DMB K4DMB K5DMB

$ 11 24 26 38

Kit consists of mounting bracket to x S3-S5 breakers onto 75mm DIN rail (EN 50023 rail) and includes 45mm high front face plate to match up with miniature circuit breakers and manual motor starters. S1 breaker mounts on 35mm DIN rail.

Mechanical interlock plate


Frame Horizontal catalog number List price Vertical catalog number List price

S3 S4 S5 S6 S7

K3MI-H K4MI-H K5MI-H K6MI-H K7MI-H

$ 570 570 590 620 630

K3MI-V K4MI-V K5MI-V K6MI-V K7MI-V

$ 570 570 590 620 630

K3DMB

Provides for mounting of two similar breakers on a single mounting plate. CBs are interlocked via a walking beam type interlock, preventing breakers from being ON or closed at the same type. Both breakers can be OFF or tripped. MIP is available in two versions, one with breakers mounted horizontally and then also a version for vertical mounting of breakers.
1 Required for drawout breakers.

15.62
AC 1000 - 11/03

Discount schedule SA

Low Voltage Products & Systems


ABB Inc. 888-385-1221 www.abb-control.com

Accessories S1 S7 IEC
Rear connected stud kits1
For breakers Max. amps

15
Is MC oma CB x s
Set of 6 catalog number List price

S3 S4 S5 S6 S7 Provides means to connect breakers directly onto rear bus bars.


K4RC

250 400 800 1200

K4RC K5RC K6RC K7RC

$ 87 225 280 340

Rear plug-in and draw-out circuit breakers


Isomax breakers are available in both rear plug-in and complete draw-out congurations. Plug-in breakers can be rear bus, front bus or front cable connected and are available up to the S5 400A size. The draw-out conguration uses a unique racking system and is available for all breakers from S3 through S7.

Plug-in (3 pole)1
Movable kit Frame Movable List price Separate kits xed and movable Fixed base kit Front bus List price Rear conn. List price Complete plug-in kits Includes both xed and movable portion Front bus List price Rear conn. List price

S1 S3 S4 S5
Rear plug-in & drawout circuit breakers

K1PMK K4PMK K4PMK K5PMK

$ 171 203 203 238

K1PFC2 K3PFF K4PFF K5PFF

$ 171 190 203 278

K1PFR K3PFR K4PFR K5PFR

$ 207 230 243 278

K1PC2 K3PF K4PF K5PF

$ 342 393 406 516

K1PR K3PR K4PR K5PR

$ 378 433 446 516

Draw-out (3 pole) 13
Movable kit Frame Movable List price Separate kits xed and movable Fixed base kit Front bus List price Rear conn. List price Complete draw-out kits Includes both xed and movable portion Front bus List price Rear conn. List price

S3 S4 S5 S6 Horiz S6 Vert S7 Horiz S7 Vert

K4WMK K4WMK K5WMK K6WMK K6WMK K7WMK K7WMK

$ 203 203 278 523 523 821 821

K3WFF K4WFF K5WFF K6WFF K6WFF K7WFF K7WFF

$ 230 283 318 1346 1346 2111 2111

K3WFR K4WFR K5WFR K6WFR-H K6WFR-V K7WFR-H K7WFR-V

$ 270 323 318 1346 1346 2111 2111

K3WF K4WF K5WF K6WF K6WF K7WF K7WF

$ 433 486 596 1869 1869 2932 2932

K3WR K4WR K5WR K6WR-H K6WR-V K7WR-H K7WR-V

$ 473 526 596 1869 1869 2932 2932

K7TUT

Movable kit = parts needed to modify standard CB to movable type. Fixed base kit = x mount onto panel. Ext Fr bus = xed base with line and load side extended front bus connectors. (FF) Rear Conn. = xed base with line and load side rear bus connectors. (FR) Complete kit = includes all parts required for plug-in or draw-out connection; does not include CB. Plug-in = open breaker can be physically removed from xed base without disconnecting cable or bus from xed base. (P) Draw-out = also known as withdrawable, breaker can be removed from xed base via a through the door crank. Includes ON, TEST and OFF position. (W)

Four pole versions (plug-in and/or draw-out)


Take the above list prices times 1.35 for four (4) pole versions and add "-4" to the end of the catalog number.

15

Draw-out crank
Isomax frames Catalog number List price

S1 S7

K7WCR

$ 20

Cable termination kits (3 pole only)1


Compression type cable lug kit used to modify extended front bus connectors for direct cable connection.
Frame Set of 6 List price

S3 S4 S5

K4FCT K4FCT K5FCT

$ 72 72 86

Hand-held test kit (for all electronic trip types)


Isomax frames Catalog number List price

S4 S5 S6 S7

K7TUT

$ 210

Isomax hand-held test kit is used to both test and exercise microprocessor trip units in breakers S4 through S7. Unit includes test forks that insert into the test plugs on all Isomax microprocessor trip units. Tester generates 15VDC signal that performs diagnostic on electronic trip functions and will conrm test by tripping the CB. Will not test S3 nor any molded case switch versions.
1 IEC ratings only. 2 Front cable connection. 3 Requires front locking device to prevent drawout while breaker is closed.

Low Voltage Products & Systems


ABB Inc. 888-385-1221 www.abb-control.com

Discount schedule SA

15.63
AC 1000 - 11/03

15
ax m s o Is CB MC

Notes

15

15.64
AC 1000 - 11/03

Low Voltage Products & Systems


ABB Inc. 888-385-1221 www.abb-control.com

Anda mungkin juga menyukai