Page:1 of 2 Doc no: Revision: Status: Made by: Approved by: Approve date: Name: ROM Oil Mills

Subject: Branch Thickness Calculation Definitions: Design data: 40-0006895 Draft SIVAKOMA

according to table 3.2-1, table 8.2-1 EN 13480-3 see also Figure 8.4.3-3 pc: 0.01 MPa pmin: 0 MPa Tmax: 580 C Tmin: -20 C EN 1.7380 RkmT: Rp02RT: Rp1.0T: Rp1.0RT: RmT: Rm: 37 280 480 MPa MPa MPa MPa MPa MPa according to pr-EN 10216-2:2002 200 000h

Material:

Dimension:

D0s: eords: D0b: eordb: z: x:


Tolerances and allowances:

1620 5 1420 5 0.7 200

mm mm mm mm

mm

distance to discontinuity

Shell

Branch

c0: c1: c2: c0: c1: c2:

1 1.00 0 1 1.00 0

mm mm mm mm mm mm

Corrosion allowance Mill tolerance Thinning allowance during manufact. Corrosion allowance Mill tolerance Thinning allowance during manufact.

Thickness used for analysis:

eas: eas: eab: eab:


Design stress: Non austenitic

eords-c0-c1-c2 3.00 eordb-c0-c1-c2 3.00

mm mm

A<30%

fcr=[ RkmT/1,25] f:

(5.3.2-1) 26.64 MPa (5.2.1-1) MPa Proof temp 266 MPa 90% on Design stress is used

ft=min[ Rp02RT/1,5; Rm/2,4] ft: 186.67 ftest=0,95*Rp02RT ftest:


Test pressure:

9.3.2.2 in prEN 13480-5 pt= max[1,43*pc ; 1,25*pc*ft/f ] pt: 0.09

MPa

Page:2 of 2 Doc no: Revision: Status: Made by: Approved by: Approve date: Name: ROM Oil Mills Subject: Branch Thickness Calculation Geometrical definitions: 40-0006895 Draft SIVAKOMA

Di: Deq: di:


deq: ls: lb:

D0s-2*eas D0s-eas D0b-2*eab D0b-eab (Deq*eas) (deq*eab) 30

1614 1617.00 1414 1417.00 69.65 65.20

mm mm mm mm mm mm

(8.4.1-4)

(8.4.1-4) (8.4.1-2) (8.4.1-3)

:
8.3.1 Thickness ratio: Figure 8.3.1-1:

angle branch, see figure 8.4.3-3

eab/eas:

1.00

di/Di:

0.88

Confirm!

di/Di < 0,8 Design according to 8.4.3 general route di/Di > 0,8 if not in creep range of material, design according to 8.4.3.(Also see ref. 8.4.4) 8.3.2 Openings in the vicinity of discontinuities

x: 200 x > max( 0,2*ls; 3*eas) =


OK Reinforcing plate:

mm 13.92982412 mm (8.3.2-1)

epl:* 0 * same material as branch

mm

epl <= eas

Confirm!

Design calculations: Operating condition:

Afs+Afb: Apl: Aps: Apb: Apbphi: Ap:

829.88 0 1438080.335 92192.36626 579012.7493 2109285.451

mm^2 mm^2 mm^2 mm^2 mm^2 mm^2

effictive area shell and branch

pressure loaded area

(f-pc/2)(Afs+Afb+Apl)>=pcAp (f-pc/2)Afs+Afb+Apl): pcAp: U:


Test condition:

condition to satisfy 22103.78702 21092.85451


OK mm^2 mm^2

0.95

(ftest-pt/2)(Afs+Afb+Apl)>=ptAp (ftest-pt/2)(Afs+Afb+Apl): ptAp: Utest: 0.84 220711.0696 184747.2242


OK

condition to satisfy

mm^2 mm^2