BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

BTS3812E-BTS3812ATS3812E-BTS3812ABTS3812AE V100R008C01B072

Upgrade Guide

HUAWEI TECHNOLOGIES CO., LTD.


December, 2013

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Contents
1 Preparations for Upgrade.............................................................1
1.1 Elementary Preparation Before Upgrading.............................................................................................................1
1.1.1 Preparing Software Needed...............................................................................................................................1
1.1.2 Preparing Hardware...........................................................................................................................................1
1.1.3 Preparing Upgrade Tool.....................................................................................................................................1
1.1.4 Preparing Data...................................................................................................................................................2
1.1.5 Points for Attention............................................................................................................................................2
1.1.6 Upgrading License.............................................................................................................................................4
1.1.7 Checking BootRom...........................................................................................................................................5
1.1.8 Checking Current Login Account......................................................................................................................6
1.1.9 Obtaining Files for Upgrade..............................................................................................................................6
1.1.10 Preparing Patch Versions of the Target Version...............................................................................................7
1.1.11 Test Before Upgrade........................................................................................................................................7
1.2 Other Preparations...................................................................................................................................................7
1.2.1 Checking Preparations of Versions, Software, and Documents........................................................................7
1.2.2 Determining Network Topology........................................................................................................................8
1.2.3 Recording States of Special Services................................................................................................................9

2 Upgrade Operations...................................................................10
2.1 Upgrade Flow........................................................................................................................................................10
2.2 Upgrade Flow........................................................................................................................................................14

3 Upgrading the NodeB from the M2000.........................................18


3.1 Checking Equipment Running Before Upgrade....................................................................................................18
3.2 Installing the M2000 Mediation Version...............................................................................................................19
3.3 Backing Up Data...................................................................................................................................................19
3.4 Checking NodeB File Server Settings...................................................................................................................19
3.5 Upgrading the NodeB............................................................................................................................................21
3.5.1 Uploading the BootRom and Flash Software Package to M2000 Server........................................................21
3.5.2 Downloading the BootRom and Flash Software Packages to the NodeB.......................................................24
3.5.3 Activating the NodeB BootRom and Flash Software Versions.......................................................................26
3.5.4 Verifying the Upgrade......................................................................................................................................30
3.5.5 Upgrading the LMT.........................................................................................................................................30
3.5.6 Finishing the Upgrade ....................................................................................................................................30
Issue 1.00

Huawei Technologies Proprietary

Page i of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

4 Upgrading the NodeB from the LMT.............................................31


4.1 Checking Equipment Running Before Upgrade....................................................................................................31
4.2 Upgrading the LMT...............................................................................................................................................32
4.3 Backing Up the Data Configuration File...............................................................................................................32
4.4 Upgrading the NodeB BootRom...........................................................................................................................32
4.5 Upgrading the NodeB Software............................................................................................................................34
4.6 Verifying the Upgrade............................................................................................................................................37
4.7 Finishing the Upgrade...........................................................................................................................................37

5 Falling Back the NodeB Version...................................................38


5.1 Falling Back the NodeB Version through the LMT...............................................................................................38
5.1.1 Falling Back the BootROM Version................................................................................................................38
5.1.2 Falling Back the Data Configuration File........................................................................................................38
5.1.3 Falling Back the NodeB Software...................................................................................................................39
5.2 Falling Back the NodeB Version Through the M2000 Client...............................................................................39

6 Handling After the Upgrade........................................................40


6.1 Refreshing Equipment Archives............................................................................................................................40
6.2 Setting the License.................................................................................................................................................40

7 Upgrade Verification...................................................................41
7.1 Verification Checklist............................................................................................................................................41
7.2 Checking Equipment Panel States.........................................................................................................................41
7.3 Checking Software Version Information...............................................................................................................42
7.4 Checking Alarm Information.................................................................................................................................43
7.5 Dialing Test for Basic Services..............................................................................................................................43
7.6 Verifying Network Problems.................................................................................................................................43
7.7 Verifying New Features.........................................................................................................................................43
7.8 Checking Equipment Running Status....................................................................................................................44
7.9 Confirming the CB................................................................................................................................................44

8 FAQ........................................................................................... 45
8.1 FAQ Table..............................................................................................................................................................45
8.2 FAQ1......................................................................................................................................................................45
8.3 FAQ2......................................................................................................................................................................46
8.4 FAQ3......................................................................................................................................................................48
8.5 FAQ4......................................................................................................................................................................48
8.6 FAQ5......................................................................................................................................................................50
8.7 FAQ6......................................................................................................................................................................50

9 Appendix................................................................................... 53
9.1 Upgrade Preparation Record.................................................................................................................................53
Upgrade Data Sheet.....................................................................................................................................................55
9.2 Dialing Test after NodeB Upgrade........................................................................................................................56

Issue 1.00

Huawei Technologies Proprietary

Page ii of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figures
Flow chart for upgrading the NodeB through the M2000 ..................13
Flow chart for upgrading the NodeB through the LMT......................13
Flow chart for upgrading the NodeB through the M2000 ..................17
Flow chart for upgrading the NodeB through the LMT......................17
File Server Setting window.............................................................20
File Server Batch Set......................................................................21
Upload software package from GUI to server...................................22
Select the directory containing the software package......................23
Choose the directory......................................................................23
Select uploading file: path being selected.......................................24
NE Upgrade Wizard : select the upgrade type and the NodeBs to
download the package...................................................................25
NE Upgrade Wizard: select the versions to download.......................26
NE Upgrade Wizard : select the upgrade type and the NodeBs to
activate the package......................................................................28
NE Upgrade Wizard: select the versions to be activated...................29
Start to upgrade the BootRom........................................................33
Upgrade the BootRom....................................................................34
Start to upgrade the software........................................................35
Upgrade the software....................................................................36
Software update result...................................................................47

Issue 1.00

Huawei Technologies Proprietary

Page iii of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Tables
Multiple NodeBs simultaneously downloading software from the
M2000............................................................................................. 2
Duration for M2000 to download NodeB software or BootROM in
typical IPoA bandwidth....................................................................2
Maximum number of the NodeBs that can be simultaneously activated
from the M2000............................................................................... 3
Comparison between licenses for 3812E of different versions.............4
Corresponding versions and necessity for upgrading the BootRom.....5
Checklist of preparations before the upgrade....................................8
Record of special services running on the network............................9
Upgrading the NodeB on the M2000................................................10
Upgrading the NodeB on the LMT....................................................11
Upgrading the NodeB on the M2000................................................14
Upgrading the NodeB on the LMT....................................................15
Checklist for equipment operation..................................................18
Verifying the upgrade....................................................................30
Checklist for equipment operation..................................................31
Verifying the upgrade....................................................................37
Verification checklist......................................................................41
Checklist for equipment panel states..............................................41
Checklist for software version information......................................42
Verifying network problems............................................................43
Verification of new features............................................................43
FAQ table......................................................................................45
Troubleshooting steps and collected data........................................49
Issue 1.00

Huawei Technologies Proprietary

Page iv of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Comparison between regular download and download by configuration


..................................................................................................... 51
Methods of adding boards of new types to the NodeB......................52
Upgrade preparation record...........................................................53
Upgrade data sheet.......................................................................55
Dialing test after NodeB upgrade....................................................56

Issue 1.00

Huawei Technologies Proprietary

Page v of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Preparations for Upgrade

1.1 Elementary Preparation Before Upgrading


1.1.1 Preparing Software Needed
Software

Description

NodeB upgrade flash


software package
NodeB upgrade
BootRom software
package

A self-extracting file that containing the flash and BootRom


software packages required for upgrade.

LMT installation
program

It is a self-extracting file that consists of the LMT installation


program.

M2000 Mediation
installation program

It consists of the installation program and related documents.

Administrator password
of the LMT PC

It is used to log in to the PC that is loaded with the LMT.

Login password of the


M2000 server
FTP/Telnet

To upload the M2000 mediation installation package to the


M2000 server, the user name and password of FTP, or at least
the upload permission, to the M2000 server is required.
To install the M2000 mediation, the user name and password of
Telnet, or at least the adaptation layer installation permission, to
the M2000 server is required.

1.1.2 Preparing Hardware


Ensure that the hardware components that should be added after the upgrade are readily
prepared."

1.1.3 Preparing Upgrade Tool

Issue 1.00

Mobile phones for dial test

SIM cards

Test vehicles

Huawei Technologies Proprietary

Page 1 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

1.1.4 Preparing Data


If the data should be reconfigured, ensure that the data is reconfigured before the upgrade and
that the NodeB works properly. For details about the reconfiguration, refer to RAN
Reconfiguration Guide.

1.1.5 Points for Attention


Pay attention to the following precautions during upgrade:
1). Upgrade NodeB software through:

M2000

The M2000 allows you to upgrade multiple NodeBs simultaneously, and is widely used in the
upgrade.

LMT

The LMT enables you to upgrade only one NodeB for each time, and is supplementary for the
upgrade.

Note:
This guide describes how to upgrade NodeBs controlled by one RNC from the M2000. If there are
multiple RNCs, follow the procedure below to upgrade NodeBs controlled by different RNCs according
to field applications.

2). Multiple NodeBs can simultaneously download the software package or BootROM
software from the M2000 under the specified IPoA bandwidth as follows:

Figure 1.1 Multiple NodeBs simultaneously downloading software from the M2000
NodeB IPoA Bandwidth

Number of NodeBs

64 kbit/s

80

128 kbit/s

40

3). The duration for M2000 to download NodeB software or BootROM in typical IPoA
bandwidth is as follows:
Figure 1.2 Duration for M2000 to download NodeB software or BootROM in typical IPoA
bandwidth

Issue 1.00

NodeB
IPoA
Bandwidt
h

NodeB
Software

NodeB
BootRom

Remarks

64K, VBR

3843

1143

The test is performed in 3 x 1


configurations. The actual
duration depends on factors

Huawei Technologies Proprietary

Page 2 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

such as the network


transmission quality, bandwidth
usage, and FTP server.
The duration listed is only for
your reference.

4). The maximum number of the NodeB software or BootROM software that can be
simultaneously activated from the M2000 is as follows:

Figure 1.3 Maximum number of the NodeBs that can be simultaneously activated from the
M2000
No.

Product

Product Version

Number of NodeBs

M2000

iManagerM2000V200R0
02C02B022 or later
versions

60

Abide by the following principles during the upgrade:


5). The upgrade procedure must be in strict compliance with the upgrade guide. No reverted
procedure is allowed.
6). During the upgrade, wait for the command response and check if the command is
executed before executing the next one. If the command fails, follow the instructions in
this guide.
7). Do not perform the following operations on NMPT when upgrading the NodeB:

Power off the NMPT


Manually reset the NMPT
Pull out or insert the NMPT

8). Do not perform the following operations on the NodeB when activating the BootROM:

Power off the NMPT


Manually reset the NMPT
Pull out or insert the NMPT

9). If a standby NMPT is available, check it before the upgrade.

The standby NMPT status is Available.


The standby NMPT does not automatically reset repeatedly.
The standby NMPT cannot be inserted or pulled out during the upgrade.

10). If the upgrade fails or the network performance seriously deteriorates in the dial test after
upgrade, fallback of version is recommended.
The fallback depends on the practical situations of the network and customers'
requirement. For details about how to perform the fallback, see 5"Falling Back the
NodeB Version".

Issue 1.00

Huawei Technologies Proprietary

Page 3 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

1.1.6 Upgrading License


If the previous functions should be maintained, you do not have to apply for a new license for
the NodeB to be upgraded from V100R006 or V100R007 to the current version.
If the new functions of HSUPA, MBMS, and power sharing in the NodeB of V100R008 are
required, you need to apply for a new license file.
For details about how to apply for a license file, refer to license user guide.
Figure 1.4 Comparison between licenses for 3812E of different versions
Version
Before
Upgrade

Differences of
License Control Items
in Upgraded Version

Impact Without
New License

Related
Operation

V100R006
C02B080

New
features

Maximum number
of HSDPA users

Maximum number of
HSDPA users

iManagerM2000V20
0R003C01B063

HSDPA RRM
Package 1

Not restricted

iManagerM2000V20
0R003C01B063

Maximum number
of HS-PDSCH
codes

Not restricted

iManagerM2000V20
0R003C01B063

HSUPA

HSUPA not supported

iManagerM2000V20
0R005

MBMS

MBMS not supported

iManagerM2000V20
0R005

Power sharing

Power sharing not


supported

iManagerM2000V20
0R005

Removed
features

New
features

HSUPA

HSUPA not supported

iManagerM2000V20
0R005

V100R007
C03B061

MBMS

MBMS not supported

V100R007
C03B061

iManagerM2000V20
0R005

Power sharing

Power sharing not


supported

iManagerM2000V20
0R005

Removed
features

New
features

V100R006
C03B090
V100R007
C03B040
V100R007
C03B043

V100R007
C03B051

V100R007
C03B062
V100R008
C01B040

Issue 1.00

15 codes per cell

Huawei Technologies Proprietary

Page 4 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Version
Before
Upgrade

Differences of
License Control Items
in Upgraded Version

Impact Without
New License

Related
Operation

V100R008
C01B050

Removed
features

V100R008
C01B060
V100R008
C01B062
V100R008
C01B070
V100R008
C01B071
V100R008
C01B072

1.1.7 Checking BootRom


You need to determine whether or not to upgrade the BootRom based on the target version
and the information. Figure 1.5 describes the corresponding versions and necessity for
upgrading the BootRom.
Figure 1.5 Corresponding versions and necessity for upgrading the BootRom
Version Before
Upgrade

Issue 1.00

BootRO
M
Upgrade
Required

Recommended BootRom
Version

BTS3812E-BTS3812ABTS3812AE
V100R008C01B072

BTS3812EBTS3812AV100R008C01B072

BTS3812E-BTS3812ABTS3812AE
V100R008C01B071

BTS3812EBTS3812AV100R008C01B072

BTS3812E-BTS3812ABTS3812AE
V100R008C01B070

BTS3812EBTS3812AV100R008C01B072

BTS3812E-BTS3812ABTS3812AE
V100R008C01B062

BTS3812EBTS3812AV100R008C01B072

BTS3812E-BTS3812ABTS3812AE
V100R008C01B060

BTS3812EBTS3812AV100R008C01B072

BTS3812EBTS3812AV100R008C01B050

BTS3812EBTS3812AV100R008C01B072

Huawei Technologies Proprietary

Page 5 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Version Before
Upgrade

BootRO
M
Upgrade
Required

BTS3812EBTS3812AV100R008C01B040

BTS3812EBTS3812AV100R007C03B062

BTS3812EBTS3812AV100R007C03B061

BTS3812EBTS3812AV100R007C03B060

BTS3812EBTS3812AV100R007C03B041

BTS3812EBTS3812AV100R007C03B040

BTS3812EBTS3812AV100R006C02B090

BTS3812EBTS3812AV100R006C02B080

Recommended BootRom
Version

BTS3812EBTS3812AV100R008C01B072

1.1.8 Checking Current Login Account


Ensure that you log in to the Windows 2000 or Windows XP system as administrator. If not,
log out and then log in to the system as administrator.
Ensure that you have the permission to upload files to the M2000 server with the user name
and password of the M2000 server FTP. If you do not have the permission, obtain the proper
user name and password so that you can upload files to the M2000 server.
Ensure that you have the permission to install the adaptation layer on the M2000 server with
the user name and password of the M2000 server Telnet. If you do not have the permission,
obtain the proper user name and password so that you can install the adaptation layer on the
M2000 server.

1.1.9 Obtaining Files for Upgrade


To obtain the files for the upgrade, perform the following steps:

Obtain the flash software package

Get the files corresponding to BTS3812E-BTS3812A-BTS3812AE V100R008C01B072 from


the server. Those files consist of the installation file of the NodeB OM system, NodeB flash
software, and M2000 mediation version file.

Decompress the version file to the destination folder

Double-click the four files respectively to enable the self-extracting. The destination folder is
D:\NodeBVer or you may rename that folder. For easy description, it is assumed that those
Issue 1.00

Huawei Technologies Proprietary

Page 6 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

files are decompressed to D:\NodeBVer under which there are four folders named
BTS3812E-12AC-12AE-BTS3812AV100R008C01B072, LMT_NodeB_BTS3812EBTS3812A-BTS3812AE V100R008C01B072, CME_BPL_BTS3812E-BTS3812ABTS3812AEV100R008C01B072 BPL and M2000_Mediation.
(1) Folder D:\NodeBVer\BTS3812E-12AC-12AE-BTS3812AV100R008C01B072
contains the NodeB flash and BootRom software package.
(2) Folder D:\NodeBVer\LMT_NodeB_BTS3812E-BTS3812A-BTS3812AE
V100R008C01B072 contains the LMT installation files.
(3) Folder D:\NodeBVer\CME_BPL_BTS3812E-BTS3812A-BTS3812AEDBS3800V100R008C01B072 BPL contains the CME BPL installation files, the CME PBL
ought to install based on the version of the WRAN CM Express V100R003C01B092.
(4) Folder D:\NodeBVer\M2000_Mediation contains the M2000 mediation installation
files.

1.1.10 Preparing Patch Versions of the Target


Version
This process is optional, depending on the need of the office.
If the office needs to upgrade corresponding version patches, get them from the technical
support website.

1.1.11 Test Before Upgrade


Perform a test before the upgrade.
For the test items, refer to the Dialing Test after NodeB Upgrade. Note down related traced
messages.
Check the upgrade memorandum of the specified version and check whether special settings
are required.

1.2 Other Preparations


1.2.1 Checking Preparations of Versions, Software,
and Documents
You need also check the following items before the upgrade:

Issue 1.00

Office for the upgrade

Upgrade schedule

Upgrade requirements from the operator

Current version to be upgraded

Target version after the upgrade

Equipment data information

Other related information required in the upgrade

Huawei Technologies Proprietary

Page 7 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Before the upgrade, refer to Figure 1.6 for preparations.


Figure 1.6 Checklist of preparations before the upgrade
Preparation

Remark

Location of the equipment to be


upgraded
Upgrade time and duration allowed by
the operator
Upgrade requirements from the operator
Type and model of the NodeB to be
upgraded
Number of NodeBs to be upgraded
Target version after the upgrade
Current version of the M2000 server at
the operator side

Confirm how many patches have been installed


so far.

Current version of the RNC at the


operator side

Confirm how many patches have been installed


so far.

Current version of the CME at the


operator side
Current flash version of the NodeB at
the operator side
Current BootRom version of the NodeB
at the operator side
Data configuration file on the operator's
equipment

Back up the data configuration file.

Transmission network topology at the


operator side
Check whether the M2000 server should
be upgraded for synchronization

If it should be upgraded, contact engineers


responsible for the M2000 server to prepare the
upgrade.

Check whether the RNC should be


upgraded for synchronization

If it should be upgraded, contact engineers


responsible for the RNC to prepare the upgrade.

Check whether the CME should be


upgraded for synchronization

If it should be upgraded, contact engineers


responsible for the CME to prepare the upgrade.

Other data that should be recorded

1.2.2 Determining Network Topology


Get ready the transmission network topology and the equipment room layout in the site for
upgrade. This enables the support engineers to understand the networking states properly.
Issue 1.00

Huawei Technologies Proprietary

Page 8 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

1.2.3 Recording States of Special Services


Before the upgrade, record the states of special services that are currently running on the
network by referring to Figure 1.7.
Figure 1.7 Record of special services running on the network
Service
Name

Is Using

CMB

Not in use
Enabled

Notes
[]
[]

Applicable only to Hong Kong at


present

Supported after this upgrade [ ]


HSDPA

Not in use
Enabled

[]
[]

Supported after this upgrade [ ]


HSUPA

Not in use
Enabled

[]
[]

Supported after this upgrade [ ]


IP RAN

Not in use
Enabled

[]
[]

Supported after this upgrade [ ]


License

Not in use
Enabled

[]
[]

Supported after this upgrade [ ]


MBMS

Not in use
Enabled

[]
[]

Supported after this upgrade [ ]


Power
sharing

Not in use
Enabled

[]
[]

Supported after this upgrade [ ]

Issue 1.00

Huawei Technologies Proprietary

Page 9 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Upgrade Operations

2.1 Upgrade Flow


Pay attention to the following precautions during upgrade:
Upgrade NodeB software through:

M2000

The M2000 allows you to upgrade multiple NodeBs simultaneously, and is widely used in the
upgrade.

LMT

The LMT enables you to upgrade only one NodeB for each time, and is supplementary for the
upgrade.
Figure 1.8 lists steps for upgrading the NodeB on the M2000.
Figure 1.8 Upgrading the NodeB on the M2000

Issue 1.00

Ste
p

Description

Refer to

Time
(hour)

Check running status of the


equipment before the upgrade.

3.1Checking Equipment
Running Before Upgrade

5min

Install the M2000 Mediation


version.

3.2Installing the M2000


Mediation Version

5min

Back up the data configuration


file.

3.3Backing Up Data

Check the NodeB file server


settings.

3.4Checking NodeB File


Server Settings

5min

Upload the BootRom and flash


software package to M2000
server.

3.5.1Uploading the BootRom


and Flash Software Package to
M2000 Server

1min

Download the BootRom and flash


software packages to the NodeB.

3.5.2Downloading the
BootRom and Flash Software
Packages to the NodeB

62minIPo
A
Bandwidth
128K

Activate the BootRom and flash


software versions.

3.5.3Activating the NodeB


BootRom and Flash Software
Version

13min

Huawei Technologies Proprietary

Page 10 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Ste
p

Description

Refer to

Time
(hour)

Verify the upgrade.

3.5.4Verifying the Upgrade

10min

Upgrade the LMT.

3.5.5Upgrading the LMT

10min

10

Finish the upgrade.

3.5.6Finishing the Upgrade

--

Figure 1.9 lists steps for upgrading the NodeB on the LMT.
Figure 1.9 Upgrading the NodeB on the LMT
Step

Description

Refer to

Time
(hour)

Check running status of the


equipment before the upgrade.

4.1Checking Equipment
Running Before Upgrade

5min

Upgrade the LMT.

4.2Upgrading the LMT

3min

Back up the data.

4.3Backing Up the Data


Configuration File

Upgrade the NodeB BootROM.

4.4Upgrading the NodeB


BootRom

30minIPo
A
Bandwidth
128K

Upgrade the NodeB software.

4.5Upgrading the NodeB


Software

37minIPo
A
Bandwidth
128K

Verify the upgrade.

4.6Verifying the Upgrade

5min

Complete the upgrade.

4.7Finishing the Upgrade

--

Figure 1.1 show the upgrade flow through the M2000.

Issue 1.00

Huawei Technologies Proprietary

Page 11 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Confirm upgrade office

Prepare the hardware and


software
Checking Equipment Running
Status before Upgrade
Installing the M2000
Mediation Version
Backing Up the Data
Configuration File
Check NodeB File Server
Settings
Uploading Software Package
to M2000 Server

Download the BootROM and


Software package to NodeB

No

All NodeB
downloading
Complete?
Yes

Act the BootROM and


Software Version

Verifying the Upgrade


No
succeed?
No

Yes

Falling Back the NodeB


Version

All NodeB activating


Complete?
Yes
Upgrading the LMT

Finishing the Upgrade

Issue 1.00

Huawei Technologies Proprietary

Page 12 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.1 Flow chart for upgrading the NodeB through the M2000

Figure 1.9 shows the upgrade flow through the LMT.


Confirm
upgrade office
Prepare the
hardware and
software
Check equipment
running status before
upgrade
Upgrade
the LMT
Back up
the data
Upgrade the
BootRom on the
NodeB
Upgrade the flash
software on the
NodeB
Verify the
upgrade
Succeed
?
Yes
Finish the
upgrade

No
Fall back the
NodeB version

Figure 1.2 Flow chart for upgrading the NodeB through the LMT

Issue 1.00

Huawei Technologies Proprietary

Page 13 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

2.2 Upgrade Flow


Pay attention to the following precautions during upgrade:
Upgrade NodeB software through:

M2000

The M2000 allows you to upgrade multiple NodeBs simultaneously, and is widely used in the
upgrade.

LMT

The LMT enables you to upgrade only one NodeB for each time, and is supplementary for the
upgrade.
Figure 1.8 lists steps for upgrading the NodeB on the M2000.
Figure 1.10 Upgrading the NodeB on the M2000
Ste
p

Description

Refer to

Time
(hour)

Check running status of the


equipment before the upgrade.

3.1Checking Equipment
Running Before Upgrade

5min

Install the M2000 Mediation


version.

3.2Installing the M2000


Mediation Version

5min

Back up the data configuration


file.

3.3Backing Up Data

Check the NodeB file server


settings.

3.4Checking NodeB File


Server Settings

5min

Upload the BootRom and flash


software package to M2000
server.

3.5.1Uploading the BootRom


and Flash Software Package to
M2000 Server

1min

Download the BootRom and flash


software packages to the NodeB.

3.5.2Downloading the
BootRom and Flash Software
Packages to the NodeB

62minIPo
A
Bandwidth
128K

Activate the BootRom and flash


software versions.

3.5.3Activating the NodeB


BootRom and Flash Software
Version

13min

Verify the upgrade.

3.5.4Verifying the Upgrade

10min

Upgrade the LMT.

3.5.5Upgrading the LMT

10min

10

Finish the upgrade.

3.5.6Finishing the Upgrade

--

Figure 1.9 lists steps for upgrading the NodeB on the LMT.
Issue 1.00

Huawei Technologies Proprietary

Page 14 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.11 Upgrading the NodeB on the LMT


Step

Description

Refer to

Time
(hour)

Check running status of the


equipment before the upgrade.

4.1Checking Equipment
Running Before Upgrade

5min

Upgrade the LMT.

4.2Upgrading the LMT

3min

Back up the data.

4.3Backing Up the Data


Configuration File

Upgrade the NodeB BootROM.

4.4Upgrading the NodeB


BootRom

30minIPo
A
Bandwidth
128K

Upgrade the NodeB software.

4.5Upgrading the NodeB


Software

37minIPo
A
Bandwidth
128K

Verify the upgrade.

4.6Verifying the Upgrade

5min

Complete the upgrade.

4.7Finishing the Upgrade

--

2.1.1 I. IStep 1Figure 1.1 show the upgrade flow through the M2000.

Issue 1.00

Huawei Technologies Proprietary

Page 15 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Confirm upgrade office

Prepare the hardware and


software
Checking Equipment Running
Status before Upgrade
Installing the M2000
Mediation Version
Backing Up the Data
Configuration File
Check NodeB File Server
Settings
Uploading Software Package
to M2000 Server

Download the BootROM and


Software package to NodeB

No

All NodeB
downloading
Complete?
Yes

Act the BootROM and


Software Version

Verifying the Upgrade


No
succeed?
No

Yes

Falling Back the NodeB


Version

All NodeB activating


Complete?
Yes
Upgrading the LMT

Finishing the Upgrade

Issue 1.00

Huawei Technologies Proprietary

Page 16 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.1 Flow chart for upgrading the NodeB through the M2000

Figure 1.9 shows the upgrade flow through the LMT.


Confirm
upgrade office
Prepare the
hardware and
software
Check equipment
running status before
upgrade
Upgrade
the LMT
Back up
the data
Upgrade the
BootRom on the
NodeB
Upgrade the flash
software on the
NodeB
Verify the
upgrade
Succeed
?
Yes
Finish the
upgrade

No
Fall back the
NodeB version

Figure 1.2 Flow chart for upgrading the NodeB through the LMT

Issue 1.00

Huawei Technologies Proprietary

Page 17 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Upgrading the NodeB from


the M2000

3.1 Checking Equipment Running Before


Upgrade
The table below lists the check items for equipment operation before upgrading the
BTS3812E-BTS3812A-BTS3812AE version to V100R008C01B072.
Figure 1.12 Checklist for equipment operation
Item
NodeB

Result

Conclusion

Checking active alarm data: Check all


alarms on the NodeBs for upgrade on
the M2000 client. Clear the alarms
according to the alarm online help.
Querying cell status: Execute DSP
LOCELL:; on the M2000 client, and
then check the state of all the NodeB
cells for upgrade.
Check if all the local and logical cells
configured are available. If not, refer
to the troubleshooting guide.
Checking data consistency: Execute
CHK DATA:; on the M2000 client,
and then check the consistency
between the NodeB FLASH data and
the service data.
If the two are not consistent, reset the
NodeB.

PC

Issue 1.00

Checking multiple IP addresses: If the


operating system running on the
computer loaded with the LMT is the
Windows 98, this computer cannot be
Huawei Technologies Proprietary

Page 18 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Item

Result

Conclusion

configured with three or more IP


addresses. Otherwise, it causes low
file transmission rate or disconnection
between the LMT and the NodeB. If
three or more IP addresses are
configured, delete the redundant
addresses.

3.2 Installing the M2000 Mediation Version


The M2000 Mediation version is applicable to the adaptation layer. The version is used by
M2000 to identify different NodeB networking modes with different versions. The software
must be installed to the M2000 server with the correct M2000 Mediation version. The M2000
Mediation version related to the BTS3812E-BTS3812A-BTS3812AE V100R008C01B072
(3812E English version) is stored in the directory of D:\NodeBVer\M2000_Mediation\
iManagerM2000(NodeB3812E_MATCH_ENG)V200R005C01B024. Therefore, install the
M2000 Mediation version by following the instructions in Installation Guide to
iManagerM2000(NodeB3812E_MATCH_ENG)V200R005C01B024 at the adaptation layer.

3.3 Backing Up Data


You dont need to back up the data configuration file.

3.4 Checking NodeB File Server Settings


Before upgrading the NodeB version, check the file server settings of all NodeBs as follows:
1). Start and log in to the M2000 client.
2). Choose Software > File Server Setting in the M2000 client interface.
3). Select the Root > NodeB > RNC1 > NodeB3812E node on the left pane in the File
Server Setting window. (The RNC name is the RNC which includes the all NodeBs you
want to upgrade. For example, RNC1, as shown in Figure 1.1.)
4). Check if the settings of all the NodeBs displayed in the right pane of the File Server
Setting window are correct.

Note:
For more details about the introduction, functions and configuration of the NodeB file server, see
8.6"FAQ5".

Issue 1.00

Huawei Technologies Proprietary

Page 19 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.1 File Server Setting window


If the file server settings of a NodeB are incorrect, change the settings as follows:
1). Start and log in to the M2000 client.
2). Choose Software > File Server Setting in the M2000 client interface.
3). Select all NodeBs to be set to the same File Server Name, and then right-click to select
the Set from the shortcut menu.
4). Set values in the File Server Batch Set window.

Issue 1.00

Huawei Technologies Proprietary

Page 20 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.2 File Server Batch Set

3.5 Upgrading the NodeB


3.5.1 Uploading the BootRom and Flash Software
Package to M2000 Server
To upload the BootRom software package to the M2000 server, perform the following:
1). Start and log in to the M2000 client.
2). Choose Software > File Transfer Wizard in the M2000 client interface. As shown in
Figure 1.1:

Issue 1.00

Select From GUI To Server in the Direction


Select OMC Server/NodeB/NodeB3812E/Software in the Server Path as show in
Figure 1.1, Then click Next.

Huawei Technologies Proprietary

Page 21 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.1 Upload software package from GUI to server


3). In the Select Software File dialog box, click the Select to add the directory containing
the software package, as shown in Figure 1.2 and Figure 1.3

Issue 1.00

Huawei Technologies Proprietary

Page 22 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.2 Select the directory containing the software package

Figure 1.3 Choose the directory


4). Click Finish in the Figure 1.4, the file transmission status (Percent and Status) is
shown in the FTP task.

Issue 1.00

Huawei Technologies Proprietary

Page 23 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.4 Select uploading file: path being selected


5). If the file transmission status is Succeeded, the software package is transferred from
GUI to server successfully.
6). If the file transmission status is error, it indicates that the file transmission fails. Repeat
steps 1) to 4). If it still fails, contact Huawei technical support engineers for
troubleshooting.

3.5.2 Downloading the BootRom and Flash Software


Packages to the NodeB
To download the BootRom and software packages to the NodeB, perform the following:
1). Start and log in to the M2000 client.
2). Choose Software > NE Upgrade Wizard > Upgrade NodeB in the M2000 client
interface.
3). In the windows of NE Upgrade Wizard, select Upgrade BootRom And Software in
the Upgrade type, and select the NodeBs for upgrade by pressing your mouse or
pressing Ctrl while clicking your mouse. before the NodeB indicates that the NodeB
is selected. before the NodeB indicates that the NodeB is not selected. Click > or
>> to add the selected NodeBs to the right pane.

Issue 1.00

Huawei Technologies Proprietary

Page 24 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide


Note
If you click

, all the selected NEs in the left pane are added to the right pane. If you click

, all the NEs in the left pane are added to the right pane.
If you click

, all the selected NEs in the right pane are moved to the left pane. If you click

all the NEs in the right pane are moved to the left pane.

Figure 1.1 NE Upgrade Wizard : select the upgrade type and the NodeBs to download the
package
4). Click Next.
The next NE Upgrade Wizard window is displayed, as shown in Figure 1.2.
5). In the window of NE Upgrade Wizard (Figure 1.2), select the following items:

Download BootROM

Download Software

Download by configuration (For information about why Download by configuration


is selected, refer to 8.7FAQ6.)

6). In the drop-down lists of BootRomVersion and SoftwareVersion, select the BootROM
and software versions for download. For example, select BTS3812E-12AC-12AEBTS3812AV100R008C01B072 in BootRomVersion and BTS3812E-12AC-12AEIssue 1.00

Huawei Technologies Proprietary

Page 25 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

BTS3812AV100R008C01B072 in SoftwareVersion.

Figure 1.2 NE Upgrade Wizard: select the versions to download


7). Click Finish.
The BootRom and software downloading is started.
8). Choose Software > Browser. Click the Immediately Task tab in the lower left part of
the window.
You may check the progress and status of the software downloading.
9). If the status displays that the BootRom and software downloading is complete, the
BootRom and software version are downloaded to the NodeB. If the status displays that
an error occurs, repeat steps 1 through 7. If the status still displays that an error occurs,
contact local Huawei office for technical support.

3.5.3 Activating the NodeB BootRom and Flash


Software Versions
To activate the BootROM and software versions, perform the following:
1). Start and log in to the M2000 client.
2). Choose Software > NE Upgrade Wizard > Upgrade NodeB in the M2000 client
interface.

Issue 1.00

Huawei Technologies Proprietary

Page 26 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

3). In the windows of NE Upgrade Wizard, select Upgrade BootRom And Software in
the Upgrade type, and select the NodeBs for upgrade by pressing your mouse or
pressing Ctrl while clicking your mouse. before the NodeB indicates that the NodeB
is selected. before the NodeB indicates that the NodeB is not selected. Click > or
>> to add the selected NodeBs to the right pane.

Issue 1.00

Huawei Technologies Proprietary

Page 27 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide


Note
If you click

, all the selected NEs in the left pane are added to the right pane. If you click

, all the NEs in the left pane are added to the right pane.
If you click

, all the selected NEs in the right pane are moved to the left pane. If you click

all the NEs in the right pane are moved to the left pane.

Figure 1.1 NE Upgrade Wizard : select the upgrade type and the NodeBs to activate the package

Note:
As downloading software and activating software are performed separately, you need to repeat the
operations" when upgrading the NodeB. Thus, the NodeB software version can be downloaded to all
NodeBs that require upgrade. Then, perform the operations in this section to activate the software. Note
that all NEs selected, should be the NodeBs that has already finished downloading the software version.
Otherwise, the activation may fail.

4). Click Next.


The next NE Upgrade Wizard window is displayed, as shown in Figure 1.2
5). In the window of NE Upgrade Wizard (Figure 1.2), select the following items:

Issue 1.00

Huawei Technologies Proprietary

Page 28 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Active BootROM

Active Software

6). In the drop-down lists of BootRomVersion and SoftwareVersion, select the BootROM
and software versions to be activated. For example, select BTS3812E-12AC-12AEBTS3812AV100R008C01B072 in BootRomVersion and BTS3812E-12AC-12AEBTS3812AV100R008C01B072 in SoftwareVersion.

Figure 1.2 NE Upgrade Wizard: select the versions to be activated


7). Click Finish.
The BootRom and software activating is started.
8). Choose Software > Browser. Click the Immediately Task tab in the lower left part of
the window.
You may check the progress and status of the software activating.
9). If the status displays that the BootRom and software activating is complete, the
BootRom and software version are activated to the NodeB. If the status displays that an
error occurs, repeat steps 1 through 7. If the status still displays that an error occurs,
contact local Huawei office for technical support.

Issue 1.00

Huawei Technologies Proprietary

Page 29 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

3.5.4 Verifying the Upgrade


Figure 1.13 Verifying the upgrade
Item

Instruction

Conclusio
n

Checking current
alarms

Check all the current alarms on the upgraded


NodeBs through the M2000 client, and
handle the alarms according to the alarm
online help.

Checking the cell


status

Execute DSP LOCELL:; on the M2000


client to check the status of all the NodeB
cells to be upgraded.

Check if all the local and logical cells


configured are available.

If yes, the upgrade succeeds.

If no, refer to the alarm online help.

Querying the
current NodeB
version

Execute LST VER:; on the M2000 client.


Then check that the current flash and
BootRom Version are all
V100R008C01B072.

Performing a
dialing test

Conduct the test by following the instructions


in Dialing Test after NodeB Upgrade.
Ensure that system services are not affected
after upgrading the NodeB.

3.5.5 Upgrading the LMT


To upgrade the NodeB LMT, perform the following:
1). Log in to the operating system on the computer with the privilege of an administrator.
2). Double-click Setup.bat under the directory of D:\NodeBVer\ LMT_NodeB_BTS3812EBTS3812A-BTS3812AE V100R008C01B072 to start installing the O&M system.
3). Install the NodeB O&M system with the default options.
The default installation directory is D:\HW LMT.

3.5.6 Finishing the Upgrade


If the NodeB is verified to be normal after the upgrade, the upgrade succeeds. Then delete the
following files under the directory of D:\NodeBVer:

Installation file of the NodeB O&M system

NodeB software package

M2000 Meditation version file

If the NodeB is verified to be abnormal after the upgrade and no exception is cleared, you
must fall back the version to restore the system.
Issue 1.00

Huawei Technologies Proprietary

Page 30 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Upgrading the NodeB from


the LMT

Note:
The CPU overload alarm may occur during the following operations:

Downloading NodeB BootROM software package

Activating NodeB BootROM

Activating board BootROM

Downloading NodeB software package

Activating NodeB software

Activating board software

The alarm is automatically cleared after upgrade.

4.1 Checking Equipment Running Before


Upgrade
The table below lists the check items for equipment operation before upgrading the
BTS3812E-BTS3812A-BTS3812AE version to V100R008C01B072.
Figure 1.14 Checklist for equipment operation
Item
NodeB

Result

Conclusion

Checking active alarm data: Check


all alarms on the NodeBs for
upgrade on the M2000 client. Clear
the alarms according to the alarm
online help.
Querying cell status: Execute DSP
LOCELL:; on the LMT, and then
check the state of all the NodeB cells
for upgrade.
Check if all the local and logical
cells configured are available. If not,
refer to the troubleshooting guide.
Checking data consistency: Execute
CHK DATA:; on the LMT, and then
check the consistency between the

Issue 1.00

Huawei Technologies Proprietary

Page 31 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Item

Result

Conclusion

NodeB FLASH data and the service


data.
If the two are not consistent, reset
the NodeB.
PC

Checking multiple IP addresses: If


the operating system running on the
computer loaded with the LMT is the
Windows 98, this computer cannot
be configured with three or more IP
addresses. Otherwise, it causes low
file transmission rate or
disconnection between the LMT and
the NodeB. If three or more IP
addresses are configured, delete the
redundant addresses.

4.2 Upgrading the LMT


To upgrade the NodeB LMT, perform the following:
1). Log in to the operating system on the computer with the privilege of an administrator.
2). Double-click Setup.bat under the directory of D:\NodeBVer\ LMT_NodeB_BTS3812EBTS3812A-BTS3812AE V100R008C01B072 to start installing the O&M system.
3). Install the NodeB O&M system with the default options.
The default installation directory is D:\HW LMT.

4.3 Backing Up the Data Configuration File


You dont need to back up the data configuration file.

4.4 Upgrading the NodeB BootRom


Note:
The exceptional reset of a board during the BootRom upgrade process may lead to damage on the
BootRom software or failure in starting the board. In this case, send the faulty board to Huawei for
maintenance.
If BootRom upgrade is not required, skip the procedure in this section.

To upgrade the NodeB BootRom, perform the following:


1). Choose Maintenance > Software Management in the left pane on the NodeB LMT.
Then double-click Software Upgrade.
Issue 1.00

Huawei Technologies Proprietary

Page 32 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

The Software Update window is displayed.

Figure 1.1 Start to upgrade the BootRom

2). Select BootRom software upgrade, and then click Next.


The BootRom Software Package Upgrade Flow is displayed.
3). Select Download BootRom Software Package and Activate NodeB BootRom
Software.
4). Enter the BootRom package path in the Directory Name box, for example,
D:\NodeBVer\BTS3812E-12AC-12AE-BTS3812AV100R008C01B072.

Issue 1.00

Huawei Technologies Proprietary

Page 33 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.2 Upgrade the BootRom

5). Click Next.


A dialog box is displayed, indicating the status and progress of upgrading BootRom.
After the BootRom package is activated, the boards that are activated and those fail to be
activated are listed.
6). If there are boards whose BootRom fails to be activated, refer to 8.2"FAQ1" "How to
handle the failure in activating the NodeB BootRom when upgrading the NodeB through
the LMT?"
Follow the steps below to continue the upgrade.

4.5 Upgrading the NodeB Software


To upgrade the NodeB software, perform the following:
1). Choose Maintenance > Software Management in the left pane on the NodeB LMT.
Then double-click Software Upgrade.
The Software Update window is displayed.
Issue 1.00

Huawei Technologies Proprietary

Page 34 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.1 Start to upgrade the software

2). Select NodeB Software Upgrade, and then click Next.


3). Select Download NodeB Software Package, Activate NodeB, and Download by
Configuration (for information about Download by Configuration, refer to
8.7FAQ6).
4). Enter the NodeB software package path in Direction Name, for example,
D:\NodeBVer\BTS3812E-12AC-12AE-BTS3812AV100R008C01B072.

Issue 1.00

Huawei Technologies Proprietary

Page 35 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.2 Upgrade the software

5). Click Next.


A dialog box is displayed, indicating the status and progress of upgrading NodeB
software. After the NodeB software is activated, the boards that are activated and those
fail to be activated are listed.
6). If there are boards whose software fails to be activated, refer to 8.3"FAQ2" "How to
handle the failure in activating the NodeB software when upgrading the NodeB through
the LMT?".
Follow the steps below to continue upgrading.

Issue 1.00

Huawei Technologies Proprietary

Page 36 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

4.6 Verifying the Upgrade


Figure 1.15 Verifying the upgrade
Item

Instruction

Conclusio
n

Checking current
alarms

Check all the current alarms on the


upgraded NodeBs through the LMT, and
handle the alarms according to the alarm
online help.

Checking the cell


status

Execute DSP LOCELL:; on the LMT to


check the status of all the NodeB cells to
be upgraded.

Check if all the local and logical cells


configured are available.

If yes, the upgrade succeeds.

If no, refer to the alarm online help.

Querying the current


NodeB version

Execute LST VER:; on the LMT. Then


check whether the current flash and
BootRom Version are all
V100R008C01B072.

Performing a dialing
test

Conduct the test by following the


instructions in Appendix C Dialing Test
after NodeB Upgrade. Ensure that system
services are not affected after upgrading
the NodeB.

4.7 Finishing the Upgrade


If the NodeB is verified to be normal after the upgrade, the upgrade is completed. Then delete
the following files under the directory of D:\NodeBVer:

Installation file of the NodeB O&M system.

NodeB software.

M2000 Meditation version file.

If the NodeB is verified to be abnormal after the upgrade and no fault is cleared, you must fall
back the version to restore the system.

Issue 1.00

Huawei Technologies Proprietary

Page 37 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Falling Back the NodeB Version

Note:
If the upgrade fails or network performance seriously declines in the dial test after upgrade, the version
needs fallback. However, fallback depends on the practical situations of the network and the customer's
requirement.

5.1 Falling Back the NodeB Version through


the LMT
5.1.1 Falling Back the BootROM Version
To fall back the BootROM version, perform the following:
1). Choose Maintenance > Software Management in the left pane on the NodeB LMT.
Then double-click Software Upgrade.
The Software Update window is displayed.
2). Select Upgrade BootRom, and then click Next.
The Upgrade Bootrom is displayed.
3). Select Activate BootRom only, and then select the version to which the current version
falls back.
4). Click Next.
A dialog box is displayed, indicating the status and progress of activating the BootRom.
After the BootRom package is activated, the boards that are activated and those fail to be
activated are listed.
5). If there are boards whose BootRom fails to be activated, refer to section 8.2"FAQ1"
"How to handle the failure in activating the NodeB BootROM when upgrading the
NodeB through the LMT?".

5.1.2 Falling Back the Data Configuration File


Falling back the data configuration file is not required.

Issue 1.00

Huawei Technologies Proprietary

Page 38 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

5.1.3 Falling Back the NodeB Software


To fall back the NodeB software, perform the following:
1). Choose Maintenance > Software Management in the left pane on the NodeB LMT.
Then double-click Software Upgrade.
The Software Update window is displayed.
2). Select NodeB Software Upgrade.
The Figure of Software Upgrade is displayed.
3). Select Activate NodeB Software only, and then select the version to which the current
version falls back.
4). Click Next.
This NodeB starts to activate its software package. After the NodeB software is
activated, the boards that are activated and those fail to be activated are listed. Then the
NodeB is automatically reset.
5). If there are boards whose BootRom fails to be activated, refer to section 8.3"FAQ2"
"How to handle the failure in activating the NodeB software when upgrading the NodeB
through the LMT?"

5.2 Falling Back the NodeB Version Through


the M2000 Client
To fall back the NodeB version through the M2000 client, perform the following:
1). You must select the basic version from Bootrom Version and Software Version to fall
back the BootRom and NodeB software versions to the basic versions.
2). Check that the NodeB works well".

Issue 1.00

Huawei Technologies Proprietary

Page 39 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Handling After the


Upgrade

6.1 Refreshing Equipment Archives


After upgrade succeeds, please update equipment archives in the equipment archive
fileserver:

If the equipment archives are in the state of documentation, follow the steps: [online
export] the equipment archives update equipment NE version and equipment software
version [online import] the equipment archives;
If the equipment archives are in the state of offline export, you should inform the
equipment archive export personnel and document administrator in the representative
office of the version information after upgrade, and ask them to update the equipment
NE version and software version before uploading the archives.

6.2 Setting the License


For the newly-added license-control information in BTS3812E-BTS3812A-BTS3812AE
V100R008C01B072, refer to section 1.1.6"Upgrading License."
To add or modify license control items, apply for or set the related license information
according to License User Guide.

Issue 1.00

Huawei Technologies Proprietary

Page 40 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Upgrade Verification

7.1 Verification Checklist


Figure 1.16 Verification checklist
No.

Item

Check Points

Checking equipment panel states

Checking version information

Checking alarm information

Dialing test for basic services

Verifying network problems

Verification of new features

Checking equipment running


status

Result

7.2 Checking Equipment Panel States


Figure 1.17 Checklist for equipment panel states

Issue 1.00

No.

Item

Check Points

Whether the equipment panel can


be properly started

Whether there is any board in red


(faulty)

Whether there is any board in


yellow (alarm)

Huawei Technologies Proprietary

Result

Page 41 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

No.

Item

Check Points

Whether there is any board in blue


(blocked)

Whether there is any board in


deep gray (in position but not
configured)

Whether there is board in fleet


gray (configured but no in
position)

Is the board configured after


upgrading is consistent with that
before upgrading?

Whether the interconnected BBUs


are properly displayed

Whether the RRUs are properly


displayed

10

Whether the RHubs are properly


displayed

11

Whether the PicoRRUs are


properly displayed

Result

7.3 Checking Software Version Information


Figure 1.18 Checklist for software version information

Issue 1.00

No.

Item

Check points

NodeB software version

V100R008C01B072

NodeB BootRom version

V100R008C01B072

NMPT version

V100R008C01B072

HULP version

V100R008C01B072

HDLP version

V100R008C01B072

HBBI version

V100R008C01B072

NUTI version

V100R008C01B072

NDTI version

V100R008C01B072

MTRU version

V100R008C01B072

10

NMON version

V100R008C01B072

Huawei Technologies Proprietary

Result

Page 42 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide


Note:
The BootRom Version information should be checked depending on the upgrade of BootRom.

If BootRom upgrade is not required, it is unnecessary to check the BootRom Version information.

If BootRom upgrade is required and the BootRom version is not released along with NodeB
software, the BootRom Version information should be checked. The check point is the BootRom
Version that is to be upgraded.

If BootRom upgrade is required and the BootRom version is released along with NodeB software,
the BootRom Version information should be checked. The check point is the BootRom Version that
is delivered with the NodeB software.

7.4 Checking Alarm Information


Check whether there are related faults or event alarms on the LMT.

7.5 Dialing Test for Basic Services


For details, refer to the Dialing Test Record for BTS3812E-BTS3812A-BTS3812AE
V100R008.

7.6 Verifying Network Problems


Perform regression test for the recorded network problems and confirm that all the problems
are solved in the new version.
Note down the results in Figure 1.19.
Figure 1.19 Verifying network problems
No.

Ticket No.

Description

Regression Test
Passed or Not

1
2
3
4

7.7 Verifying New Features


Figure 1.20 Verification of new features
No.

Feature
Description

Description of
Test Cases

Result

1
2

Issue 1.00

Huawei Technologies Proprietary

Page 43 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

No.

Feature
Description

Description of
Test Cases

Result

3
4

7.8 Checking Equipment Running Status


Check the equipment running status and compare running specifications of the equipment
before upgrade and those after upgrade.

7.9 Confirming the CB


If the NodeB works properly based on the check after the upgrade, use the CFM CB
command to confirm the running version including the software version and the data
configuration file. Then, a new Configuration Baseline (CB) is generated.
You can use the CFM CB command when you need to back up the currently running CB.
To confirm the CB, perform the following steps:
1). Click the MML command->System Management->CB Management. Choose "CFM
CB"(Confirm Configuration Baseline).
2). Select Confirm Mode(FORCED or UNFORCED), and then enter the CB name and
comments (optional).
3). Click

Issue 1.00

or press F9 on the keyboard.

Huawei Technologies Proprietary

Page 44 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

FAQ

8.1 FAQ Table


Figure 1.21 FAQ table
No.

Question

FAQ1

How to handle the failure in activating the NodeB BootRom when upgrading
the NodeB through the LMT?

FAQ2

How to handle the failure in activating the NodeB software when upgrading
the NodeB through LMT?

FAQ3

How to clear the fault in abnormal IPoA channel at the far end, or in a broken
link between the M2000 and the NodeB after the NodeB is upgraded?

FAQ4

How to handle the failure in accessing the NodeB by some UEs after the
NodeB is upgraded?

FAQ5

What is the function of the NodeB file server?

FAQ6

Why the download rate can be faster during the upgrade process when
"download by configuration" is selected?

8.2 FAQ1
I. Question
How to handle the failure in activating the NodeB BootROM when upgrading the NodeB
through the LMT?

II. Answer
First, list the boards that fail to be activated according to the results of NodeB BootRom
activation. You may choose to activate one board only or all boards of the same type,
depending on the results of NodeB BootRom activation. The latter method is applicable to
situations when there are a number of boards of the same type fail to be activated.

Issue 1.00

Huawei Technologies Proprietary

Page 45 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

To activate board BootRom, perform the following:


1). Choose Maintenance > Software Management in the left pane on the NodeB LMT.
Then double-click Software Upgrade.
The Software Update window is displayed.
2). Select Activate Board, and then click Next to display the Software Upgrade Activate
Board dialog box.
3). Select Single board in the Activate BOOTROM field, and then enter the related
subrack number and the slot number.
If there are a number of boards whose BootROM fails to be activated and the boards belong to
the same type, select A type of boards in the Activate BOOTROM field. Select the type of
boards to be activated from the Board type drop-down box.
4). Click Next to activate the BootRom of a single board or a type of boards.
Follow the steps above to activate the BootRom of other types of boards.

8.3 FAQ2
I. Question
How to handle the failure in activating the NodeB software when upgrading the NodeB
through the LMT?

II. Answer
First, lick the View Details button to list the boards that fail to be activated according to the
results of NodeB software activation. You may choose to activate one board only or all boards
of the same type, depending on the results of NodeB software activation. The latter method is
applicable to situations when there are a number of boards of the same type fail to be
activated.

Issue 1.00

Huawei Technologies Proprietary

Page 46 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.1 Software update result


Activate board software as follows:
1). Choose Maintenance > Software Management in the left pane on the NodeB LMT.
Then double-click Software Upgrade.
The Software Update window is displayed.
2). Select Activate Board, and then click Next to display the Software Upgrade Activate
Board dialog box.
3). Select Single board in the Activate Software field, and then enter the related subrack
number and the slot number.
If there are a number of boards whose BootROM fails to be activated and the boards belong to
the same type, select A type of boards in the Activate Software field. Select the type of
boards to be activated from the Board type drop-down box.
4). Click Next to activate the software of a single board or a type of boards.
Follow the steps above to activate the software of other types of boards.

Issue 1.00

Huawei Technologies Proprietary

Page 47 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

8.4 FAQ3
I. Question
How to clear the fault in abnormal IPoA at the far end and in a broken link between the
M2000 and the NodeB after the NodeB is upgraded?

II. Answer
If the NodeB IPoA address fails to be pinged, refer to the reasons and related solutions below:
Reason 1: The related alarms show that the E1 link between the RNC and the NodeB is
abnormal or faults occur to IMA/UNI/CP ports.
Solution 1: Clear the fault in E1 transmission until all related alarms are cleared.
Reason 2: The MML command of DSP E1T1 executed at the RNC indicates the IMA groups
at the RNC and the NodeB fail to interwork due to the fact that there is an E1 working in
loopback mode in the IMA group of the NodeB configured at the RNC.
Solution 2: Reset the IMA group at the RNC. If the IPoA is still abnormal, reset the IMA
group after removing the E1 working in loopback mode at the RNC.
Reason 3: Field check shows that the RUN/ALM/ACT indicators on the HBBU are
abnormal.
Solution 3: Contact the person in charge of Huawei technical support or NodeB
troubleshooting specialist as soon as possible. Collect related data under the guidance of the
specialist. After getting the approval by the specialist, reset, pull out, install, or replace the
HBBU until all related faults are cleared.
Reason 4: Login to the NodeB through the near-end Ethernet port from the LMT fails. The IP
address cannot be pinged.
Solution 4: Contact the person in charge of Huawei technical support or NodeB
troubleshooting specialist as soon as possible. Collect related data under the guidance of the
specialist. After getting the approval by the specialist, reset, pull out, install, or replace the
HBBU until all related faults are cleared.

8.5 FAQ4
I. Question
How to handle the failure in accessing the NodeB by some UEs after the NodeBs are
upgraded?

II. Answer
Contact the person in charge of Huawei technical support or NodeB troubleshooting specialist
as soon as possible. Collect related data under the guidance of the specialist. Troubleshoot the
failure at the remote end until all related faults are cleared.
Refer to the table below for troubleshooting steps and collected data.

Issue 1.00

Huawei Technologies Proprietary

Page 48 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.22 Troubleshooting steps and collected data


Actions

Results

Data Collected

Check NodeB active alarms through the LMT,


and then clear the alarms if any.

NodeB alarm data

Check active alarms associated with the


NodeB through the LMT at the RNC, and then
clear the alarms if any.

NodeB alarm data

Upload the HBBU log file by executing ULD


FILE: DSTF="c:\", FLAG=HBBULOG,
IP="10.161.41.71", USR="admin",
PWD="admin", CF=UNCOMPRESSED;

Uploaded HBBU logs

Confirm that local cells are available at the


NodeB by executing DSP CELL. Confirm that
logical cells at the RNC are OK by executing
DSP CELL.

MML command messages


saved

Confirm that the NodeB output power is


normal.

MML command messages


saved

Check the locking of frequency and scramble


of the UE under test.
Check the accessibility of the new UE or the
new UE SIM card.

Issue 1.00

If possible, check whether the UE under test


originates the RRC CONNET REQ message.

Logs recorded

Check that the NodeB RTWP is normal with


the value at 106 dBm 3 dB

RTWP measurement files


recorded

Query Iub micro channel data carried over all


AAL2PATHs of the NodeB by executing DSP
AAL2CHN at the RNC.

MML command messages


saved

Trace and save all messages of the UE under


test through single UE tracing at the RNC.

Single UE tracing

Trace and save all messages of the UE under


test over the Uu, Iu, Iub interfaces.

Messages traced over Iu,


Iub and Uu interfaces

Trace messages over the Iub interface of the


NodeB.

Messages traced over


NodeB Iub interface

Export RNC CDR log files before and after


NodeB upgrade.

CDR log files before and


after NodeB upgrade

Huawei Technologies Proprietary

Page 49 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

8.6 FAQ5
I. Question
What is the function of the NodeB file server?

II. Answer
To upgrade NodeB software, you must configure the NodeB file server to the M2000. The
server is used to store NodeB software packages and to provide FTP server services for the
NodeB to be upgraded. When upgrading software, the NodeB needs to download the software
package from the file server.
The NodeB file server can be configured either to the M2000 or to the related RNC. The
server, if configured to the RNC, has the following advantages:
1). During the upgrade, the NodeB can download software in batches from the related RNC
at a faster speed than from the file server configured to the M2000.
2). If there is a firewall restricting the NodeB FTP Client from accessing the M2000 server
in the IP network configuration, software fails to be downloaded from the NodeB file
server configured to the M2000. Instead, software can be normally downloaded from the
NodeB file server configured to the RNC.
Therefore, it is suggested to set the default configuration of the NodeB file server to the RNC.

Note:
Before upgrade, you only need to check that the NodeB file server is correctly configured.

If the configuration of the NodeB file server is correct, the system automatically downloads the
NodeB software package from the M2000 server to the NodeB file server without any manual
operations.

8.7 FAQ6
I. Question
Why the download rate can be faster during the upgrade process when "download by
configuration" is selected?

II. Answer
The NodeB software package contains the software for all the boards supported by the
NodeB. Each board type corresponds to one board software package.
In regular mode, the entire NodeB software package is downloaded to the NodeB. However,
in actual application, only some types of boards are configured on the NodeB and not all the
software packages are required.
Therefore, "download by configuration" refers to downloading the required board software
packages from the file server during the upgrade process in compliance with the types of
boards currently configured on the NodeB. This can effectively reduce the total data volume
in the download, minimize the duration, and ensure that the software packages use least
storage space on the hard disk.

Issue 1.00

Huawei Technologies Proprietary

Page 50 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Generally, "download by configuration" has the following benefits:

Download only the required board software from the software package according to the current
NodeB configuration.
Use the valuable maintenance link bandwidth effectively, minimize the duration for
downloading the software, and improve the upgrade efficiency.
Use the storage space on the hard disk of the NodeB effectively and avoid waste of storage
space for software not to be used.
The download rate in this mode will be faster when the NodeB has boards of fewer types.
Figure 1.23 Comparison between regular download and download by configuration

Typic
al
Confi
gurati
on

Board
Typ
e

Quantit
y

Regula
r

By
Confi
gurati
on

Regula
r

By
Configu
ration

BTS381
2EBTS381
2A 3 x 1
configur
ation

NMP
T

80 min.

40 min.

30
Mbytes

15 Mbytes

64 kbit/s

NUTI

HBBI

MTR
U

MAF
U

HBB
U

60 min.

50 min.

21
Mbytes

18 Mbytes

64 kbit/s

MRR
U

DBS380
03x1
configur
ation

Duration

Storage Space
Bandwidth

Note:
The NodeB uses one active directory and one standby directory to store two pieces of software. The
space saved on the hard disk in this situation will be:

BTS3812E-BTS3812A: 15 Mbytes x 2 = 30 Mbytes

DBS3800: 3 Mbytes x 2 = 6 Mbytes

Since there are differences between the two download modes, the methods of adding boards
of new types to the NodeB vary as follows:

Issue 1.00

Huawei Technologies Proprietary

Page 51 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Figure 1.24 Methods of adding boards of new types to the NodeB


Mode

Description

How to Add
New Board

Exception

Remarks

Regular
download

Download the
entire NodeB
software package
to the NodeB.

Obtain the board


software directly
from the NodeB
and automatically
activate it.

None.

None.

Download by
configuration

Download only the


required board
software for the
boards currently
configured on the
NodeB.

Obtain the software


from the specified
file server and
automatically
activate it to
upgrade the boards.

Alarms will be
reported if the
file server
cannot be
connected or
no
corresponding
versions are
found on the
server.

Alarm ID:
ALM-3539.

Note:
The NodeB of V100R007 supports "download by configuration" for the flash on the boards but does
not support "download by configuration" for the BootROM. The NodeB BootROMs must be
downloaded in regular mode.

Issue 1.00

If the alarm with the ID 3539 is generated, run the MML command SPL SOFTWARE to
supplement the software.

Huawei Technologies Proprietary

Page 52 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Appendix

9.1 Upgrade Preparation Record


Figure 1.25 Upgrade preparation record
Items

Description

Remarks

Equipment name
Equipment location
Date and time approved by the
customer

Upgrade the NodeB version when the


traffic is light, for example, late at night.

Customer requirements
Version before upgrade
Version after upgrade
Version requirements of
associated products
Software for upgrade
Data for upgrade

It is not necessary to prepare data for


upgrade if there is no change in data
configuration.

Hardware for upgrade

It is not necessary to prepare hardware


for upgrade if hardware is not involved in
upgrade.

Tools for upgrade

The tools for upgrade include special


upgrade tools, UE, SIM card, and
Ethernet cables.

53

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Items

Issue 1.00

Description

Remarks

Upgrade engineers

The upgrade engineer team is usually


made up of those on the customer's side
as well as those from HUAWEI.

Associate engineers

The upgrade might involve other


engineers, for example, in O&M, in
network planning, and in drive test.

Transportation vehicles

The upgrade might involve the use of


vehicles for drive test.

Person in charge

Names and phone numbers are required.

Huawei Technologies Proprietary

Page 54 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Upgrade Data Sheet


Figure 1.26 Upgrade data sheet
Operator name

Upgrade
date
Version after
upgrade
Engineers assigned by operator:
Engineers from Huawei:

Version before
upgrade
Engineers
responsible for
the upgrade
Upgrade
succeeds?
Upgrade Actions
Check operating
state before
upgrade
Upgrade
procedure

Verifying
upgrade

Conclusi
on

Check multiple IP addresses.


Check active alarm data.
Query cell status.
Check data consistency.
Back up data.
Check the configuration of
the NodeB file server.
Upload the software package
to the M2000 server.
Download the NodeB
BootROM.
Download the NodeB
software package.
Activate the NodeB
BootROM.
Activate NodeB software
package.
Query active alarm data.
Check cell status.
Query version information.
Check dialing tests.

Upgrade the
LMT

55

Handling
Suggestions
upon Abnormity

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

9.2 Dialing Test after NodeB Upgrade


Figure 1.27 Dialing test after NodeB upgrade
Record of NodeB Dialing Test

NodeB Name
Test time
Test result

Pass Not Pass

Cell name
Cell ID
Cell scramble

Dialing Test

Result

Speech: fixed-line
phone to mobile (3G)

Pass NotPass N/A

Speech: mobile (3G)


to fixed-line phone

Pass NotPass N/A

Speech: mobile (3G)


to mobile (2G)

Pass NotPass N/A

Speech: mobile (2G)


to mobile (3G)

Pass NotPass N/A

Speech: mobile (3G)


to mobile (3G)

Pass NotPass N/A

VP: mobile (3G) to


mobile (3G)

Pass NotPass N/A

PS: PDP activation

Issue 1.00

Pass NotPass N/A

Speech conversation
quality

Good Bad N/A

VP conversation
quality

Good Bad N/A

PS communications
quality

Good Bad N/A

Call dropped

Remarks

Pass NotPass N/A

Huawei Technologies Proprietary

Page 56 of 57

BTS3812E-BTS3812A-BTS12AE V100R008C01B072 Version Upgrade Guide

Soft handover

Pass NotPass N/A

RSCP (should: > 70


dBm)
Ec/I0 (should: > 10
dB)

Remarks

Tested by
(signature)

Issue 1.00

Huawei Technologies Proprietary

Page 57 of 57