Anda di halaman 1dari 2

SQUARE WALL MOUNT

12" (305 mm) PERIMETER CUTOFF


Ballast Sealing Gasket 0.25" (6 mm) Housing Die-Cast Aluminum DeltaGuard finish Lens Spring-Clip Assembly Hidden from view Lamp (Included) 5" (127 mm) Polycarbonate Lens Lampholder Capacitor

SE3-12 SERIES

3.1" (79 mm) Silicone Gasket

1/2"-14 NPT Threaded Hub

UP

UP

Notes

12" (305 mm) Reflector Prefinished semi-specular aluminum Bronze Polycarbonate Shroud
1/2"-14 NPT Threaded Hub

BOTTOM VIEW
WATTAGE CATALOG #

SPEC

SPEC #

MOUNTING POSITION #

(a) VOLTAGE SUFFIX KEY


D 120/277V M  120/208/240/277V
(Standard: PSMH; HPS)

(b) OPTIONS (factory-installed)


-(a)F Fusing J Tamperproof Lens Fasteners -(a)P Photocell Q  Quartz Standby
(includes 100W quartz lamp) (N/A on 277V Reactor)
Specify (a) Single Voltage See Voltage Suffix Key

SPEC #

SPEC #

SPEC #

SPEC #

SPEC #

PULSE START METAL HALIDE Wall Downlight 100W PSMH SE3410-(a)(b) Wall Downlight 150W PSMH SE3615-(a)(b) HIGH PRESSURE SODIUM Wall Downlight 100W HPS SE3510-(a)(b) Wall Downlight 150W HPS SE3515-(a)(b) FLUORESCENT Any 26/32/42W FL SE3242-(a)(b) Any 57W FL SE3257-(a)(b)

T  120/277/347V (Canada Only)


(PSMH; HPS)

1 120V Reactor (100-150W HPS) 2 277V 27 277V Reactor (150W PSMH Only) 3 208V 4 240V 6L 347V (26 57W FL) (Canada Only) UL  120 277V Universal Voltage
(Standard: 26/32/42/57W FL)
For voltage availability outside the US and Canada, see Bulletin TD-9 or contact your Ruud Lighting authorized International Distributor.

Specify (a) Voltage & (b) Options. 

GENERAL DESCRIPTION Aluminum die-cast housing supplied. Knockouts are provided on the back of the housing for 1/2" conduit entry or for mounting over a single gang box, 4" square or 4" octagon boxes. Two #8 x 1" threaded studs and nuts are provided for mounting over a junction box. Housing also includes 1/2"-14 NPT threaded hubs on four sides for conduit entry. 0.25 thick silicone sponge gasketing on the back of the housing provides a watertight mounting seal. Silicone sponge cord gasket between housing and lens ensures a water- and insect-tight seal. Injection molded clear poly carbonate lens and shroud assembly is held in place using a hidden spring clip assembly. Semi-specular reflector directs light downward to wash the wall below and to the sides of fixture. Extra wide cutoff distribution provides glare control and permits maximum spacing between fixtures.

ELECTRICAL  Fluorescent fixture includes a 26, 32, 42 or 57W triple tube, compact fluorescent lamp. HID fixtures include a clear, medium-base lamp and porcelain enclosed, 4kv-rated screw-shell-type lampholder with spring-loaded center contact. Lamp ignitor included where required. HID and FL electronic ballast assemblies are high-power factor. Use the following circuit types: 120V Reactor 100 150W HPS 277V Reactor 150W PSMH HX High Reactance 100 150W PSMH; 100 150W HPS Electronic (120 277V Universal Voltage [50/60Hz] & 347V [60Hz]) (minimum starting temperature 0F [-18C]) 26/32/42/57W FL

LABELS ANSI lamp wattage label supplied, visible during relamping. ULListed in the US and Canada for wet locations and enclosure classified IP54 per IEC 529 and IES 598. FINISH Housing is standard with our exclusive Colorfast DeltaGuard finish, featuring an E-coat epoxy primer with bronze ultra-durable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. The finish is covered by our seven-year limited warranty. ACCESSORIES
TPS-1 Tamperproof Screwdriver

2011 Ruud Lighting, Inc. A Cree Company. All rights reserved. The information in this document is subject to change without notice. 9201 Washington Avenue Racine, Wisconsin 53406-3772 PHONE: (800) 236-7000 FAX: (800) 236-7500 WEB: www.ruudlightingdirect.com
Rev. 05/02/12

SE3-12 SERIES

SQUARE WALL MOUNT

12" (305 mm) PERIMETER CUTOFF


Isofootcandle plots show initial footcandles at grade. (Footcandles 0.0929 = Lux) ANGLE 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 52.5 55.0 57.5 60.0 62.5 65.0 67.5 70.0 MEAN CP 1519 1642 1859 2112 2064 2225 2233 2380 2960 1731 3328 3341 3382 3506 3441 3274 3597 4205 4797 ANGLE 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 95.0 105.0 115.0 125.0 135.0 145.0 155.0 165.0 175.0 180.0 MEAN CP 5024 4498 3362 2335 1621 550 110 50 42 58 74 100 110 124 124 20 17 6

90

2000
30

60

6000

ISO SE3 12" 175W MH 15'


Front View Lighting Sciences Inc. Certified Test Report No. LSI 11797 Candlepower distribution curve of 175W MH 0 Square Perimeter Cutoff Fixture.

Maximum Candlepower: 5024 Plane of Maximum CP: 82.5 Vertical Angle of Maximum Candlepower: 72.5 Lumen Rating: 14000

efficiencY = 71.1%

Distance In Units of Mounting Height

MOUNTING HEIGHT 90 CONVERSION TABLE


1
1

Footcandle readings for mounting heights other than 15' (4.6 m) may be obtained by multiplying fc values by the following:

.5 .3

2000 4000
.1 .05

6000

30

8.0' (2.4 m) 10.0' (3.0 m) 12.0' (3.7 m) 20.0' (6.1 m) 25.0' (7.6 m)

60

HEIGHT

FACTOR 3.52 2.25 1.56 0.56 0.36

4 0

LAMP WATTAGE CONVERSION TABLE


5
Footcandle readings for wattages and lamp types other than 150W PSMH may be obtained by multiplying fc values by the following: LAMP/WATTAGE 26W FL 32W FL 42W FL 57W FL 100W PSMH 100W HPS 150W HPS MULTIPLIER 0.12 0.16 0.23 0.31 0.64 0.68 1.14

1 4 2 3 Distance In Units of Mounting Height

Isofootcandle plot of 150W PSMH Square Perimeter Cutoff fixture at 15' (4.6 m) mounting height. (Plan view)

100M100Y

2011 Ruud Lighting, Inc. A Cree Company. All rights reserved. The information in this document is subject to change without notice. 9201 Washington Avenue Racine, Wisconsin 53406-3772 PHONE: (800) 236-7000 FAX: (800) 236-7500 WEB: www.ruudlightingdirect.com

ontaje

Rev. 05/02/12

Anda mungkin juga menyukai