Anda di halaman 1dari 2

Product data sheet

Characteristics

RXM4LB2BD

miniature plug-in relay - Zelio RXM4L - 4 C/O 24 V DC - 3 A - with LED

Main
Commercial Status Range of product Series name Product or component type Device short name Coil interference suppression Utilisation coefficient Sale per indivisible quantity Commercialised Zelio Relay Miniature Plug-in relay RXM Without 20 % 10
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Complementary
Contacts operation Control circuit voltage [Ithe] conventional enclosed thermal current Status LED Control type [Ui] rated insulation voltage [Uimp] rated impulse withstand voltage Contacts material [Ie] rated operational current Minimum switching current Maximum switching voltage Minimum switching voltage Load current Maximum switching capacity Minimum switching capacity Operating rate Mechanical durability Electrical durability Average consumption in W Drop-out voltage threshold Operating time Average resistance Rated operational voltage limits Protection category Operating position CAD overall width CAD overall height CAD overall depth Product weight
Nov 4, 2013

Standard 24 V DC 3 A at -40...55 C With Without pushbutton 250 V conforming to IEC 3.6 kV (1.2/50 s) conforming to IEC 61810-7 Silver alloy (Ag/Ni) 1.5 A (AC-1/DC-1) NC conforming to IEC 3 A (AC-1/DC-1) NO conforming to IEC 10 mA 250 V DC 250 V AC 17 V 3 A at 28 V DC 3 A at 250 V AC 84 W network: DC 750 VA network: AC 170 mW <= 18000 cycles/hour no-load <= 1200 cycles/hour under load 10000000 cycles 100000 cycles for resistive load 0.9 W DC DC: >= 0.1 Uc 20 ms between coil energisation and making of the On-delay contact 20 ms between coil de-energisation and making of the Off-delay contact 630 Ohm network: DC at 20 C +/- 10 % 19.2...26.4 V DC RT I Any position 21 mm 27 mm 46 mm 0.034 kg 1

Environment
Dielectric strength 1000 V AC between contacts 2000 V AC between poles 2000 V AC between coil and contact CE EN/IEC 61810-1 (iss. 2) RoHS compliant -40...85 C -40...55 C 6 gn, amplitude = +/- 1 mm (f= 10...50 Hz)not operating conforming to EN/IEC 60068-2-6 3 gn, amplitude = +/- 1 mm (f= 10...50 Hz)operating conforming to EN/IEC 60068-2-6 IP40 conforming to EN/IEC 60529 5 gn for closing conforming to EN/IEC 60068-2-27 10 gn for opening conforming to EN/IEC 60068-2-27

Standards

Ambient air temperature for storage Ambient air temperature for operation Vibration resistance

IP degree of protection Shock resistance

Offer Sustainability
Sustainable offer status RoHS REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 0848 Available Schneider Electric declaration of conformity

Reference not containing SVHC above the threshold Download Product Environmental Need no specific recycling operations