Anda di halaman 1dari 8

PCM controller unit PCMC2bis

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43018 AFXX

Function
This unit forms the interface between the 2 Mbit/s line signal and the tributaries connected to the internal bus. The PCM controller fulfils the common functions of the multiplexer : configuration control and main processing of voice/data and interface with common alarm system for man-machine communication. The AFXX version of this unit has a special feature : the operational firmware can be downloaded into the controller`s memory using a PC. For this purpose the 9-pin F interface connector should be connected to the PC`s serial port.

Operational data
2 Mbit/s input and output signal : D D D D D D D conform to ITU-T recommendations G.703 to G.706, G.732, G.735, G.736, G.772 bit rate : 2048 kbit/s + 50 ppm number of channels : 30 frame structure : ITU-T G.704 signalling mode : CAS interface signal : HDB3 pulse mask, levels, impedances : ITU-T G.703

DOCC: MMCC:

*NA *NA 990118

3AL 43018 AFAA TNAAA Ed. 01

1/8

Front view

Red LED

Green LED

9-pin connector (J) (firmware download)

RJ45 connector (I) for EOC1 RJ45 connector (H) for EOC2 RJ45 connector (G) input & output signal test points Coax connector (F) G.703 output 75 RJ45 connector (E) G.703 input & output 120 Coax connector (D) G.703 input 75

2/8

3AL 43018 AFAA TNAAA Ed. 01

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43018 AFXX

PCM controller unit PCMC2bis

PCM controller unit PCMC2bis


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43018 AFXX

Front side indications


AL : red LED, normally off. When on or flashing, it indicates an alarm situation on the unit. AC : green LED, normally flashing. When on or off, it indicates an alarm situation on the unit. RED LED Off On Flashing Off On Off GREEN LED Flashing Flashing Flashing On On Off MEANING Normal operation 2 Mbit/s link or tributary alarm Configuration mismatch Unit in monitor mode Failing system clock Power failure Failing self test Hardware failure Self test (< 30 s)

Repetitive sequence (> 5 s) Other sequence Undefined

For detailed information, refer to section 6 of the technical manual : fault location.

Front connectors
Front connector D and F : G.703 input and output signals at 75 (for 120 use connector E) Front connector E : G.703 input and output signals at 120 (for 75 use connectors D and F) :

1 2 3 4 5 6 7 8

: LIN120Y : LIN120Z : LIN120G : LOUT120Y : LOUT120Z : Safety ground : Safety ground : Safety ground

Meaning :

Front view of board connector LOUT : Transmit output test point : LIN : Receive input test point : -

Front view of cable plug

120Y : to be connected to 120 symmetrical cable 120Z : to be connected to 120 symmetrical cable 120G : screen can be connected to safety ground

3AL 43018 AFAA TNAAA Ed. 01

3/8

Front connector G : test points for G.703 input and output signals :

1 2 3 4 5 6 7 8

: LINM120Y : LINM120Z : LOUTM75Y : LOUTM120Y : LOUTM120Z : LOUTM75Z : LINM75Y : LINM75Z

Front view of board connector Meaning : LOUTM : Transmit output test point : LINM : Receive input test point : -

Front view of cable plug

120Y : to be connected to 120 symmetrical cable 120Z : to be connected to 120 symmetrical cable 75Y : to be connected to core of 75 coax cable 75Z : to be connected to screen of 75 coax cable

Front connector I and H : EOC 1 and 2 (only from Release 5.x on) :

1 2 3 4 5 6 7 8

: EOCi TX P : EOCi TX N : EOCi CLK P : EOCi RX P : EOCi RX N : EOCi CLK N : Safety ground : Safety ground

Front view of board connector Meaning : EOCi TX : Transmit input : EOCi RX : Receive output : EOCi CLK : Clock access : P : signal wire N : ground wire

Front view of cable plug

4/8

3AL 43018 AFAA TNAAA Ed. 01

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43018 AFXX

PCM controller unit PCMC2bis

PCM controller unit PCMC2bis


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43018 AFXX

Front connector J : used to connect the PCMC2bis to a PC`s serial com port for test purposes or firmware download into the controller`s memory via a cable 772 55123 XXXA. Refer to the separate manual of the download software.

Strap options
For the location of the switches refer to figure 1. The coax shield or symmetrical cable screen of the 2 Mbit/s PCM input signal can be grounded or floating by means of the switches S1958 and S1929 : Configuration Coax cable 75 shield grounded Coax cable 75 shield grounded via 22 nF Coax cable 75 shield floating Symmetrical cable 120 screen grounded Symmetrical cable 120 screen floating S1958 A B B A A or B S1929 A or B B A A A

The system clock output to the backpanel (C2OF-C2OT) can be grounded or floating by means of the switches S2041 and S2040 : Configuration 75 with ground on C2OT 75 with ground on C2OF 75 floating 120 (floating) S2041 A A B B S2040 A B A or B A or B

The external clock synchronization input from the backpanel (ECLKIF-ECLKIT) can be grounded or floating by means of the switches S2028 and S2027 : Configuration 75 with ground on ECLKIT 75 with ground on ECLKIF 75 floating 120 (floating) S2028 A A B B S2027 A B A or B A or B

3AL 43018 AFAA TNAAA Ed. 01

5/8

A S2028 S2027 S2013 S2001 A B

1 2 3 X860

A B

H S2041 S2040 G F E D S1958 S1929 B A

Processor 1
B

Figure 1

Position of the straps on the PCMC board

6/8

3AL 43018 AFAA TNAAA Ed. 01

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43018 AFXX

PCM controller unit PCMC2bis

PCM controller unit PCMC2bis


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43018 AFXX

The external clock synchronization input from the backpanel (ECLKIF-ECLKIT) can be terminated or not by means of the switches S2001 and S2013 : Configuration 75 termination 120 termination High impedance S2001 A A B S2013 A B B

The straps on X860 are only used during board test, as ther are normally not accessible : D connection A1-B1 : Reset D connection A2-B2 : Test (monitor) mode or software download mode. D connection A3-B3 : not connected To proceed with the software download, pins A2 and B2 have to be connected as indicated on Figure 1. During normal operation, no straps may be present on X860. After board test and firmware download, the strap must be removed.

ATTENTION

3AL 43018 AFAA TNAAA Ed. 01

7/8

8/8

3AL 43018 AFXX PCM controller unit PCMC2bis

3AL 43018 AFAA TNAAA Ed. 01


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.