AIR CURTAINS Description

The new and attractive generation of Airtcnics air curtains is the ideal solution to maintain a comfortable interior climate in commercial outlets and public buildings that need to keep their doors open. Airtcnics air curtains create an air stream layer over the doorway and act as an invisible barrier which efficiently divides the inside environment from the outside one. Therefore, it substantially reduces heating and cooling costs up to 80%, while increasing employees and clients comfort. For shops, Airtcnics air curtains allow a clear view of the inside of the shop, welcoming the client to enter easily and freely. The end result is more customers and an increase in sales. Airtcnics air curtains are a protection from the cold and heat, repel gusts of wind and minimize dust, fumes, pollution and insects entering the building. In order to obtain these advantages its very important to choose the appropriate air curtain. Factors such as interior drop, strong winds, the doors location, stairs between floors, opposite doors, and the installation height have to be taken into consideration. Our expert consultants with their extensive experience are at your disposal to help you choose.

Advantages
MAINTAINS - Heating levels - Refrigeration - Air conditioning - Comfort - Clean atmosphere PROTECTS FROM - Cold winter temperatures - Hot summer temperatures - Car fumes - Dust in the air - Pollution - Bad smells and odours - Insects

Selection of an air curtain


To select an air curtain the following factors have to be kept in mind: - - - - - - - - - - The height of the installation measured from the discharge diffuser to the floor The width of the door The location of the building to determine the level of protection needed against weather conditions If the building has several doors in the same, different or opposite faade If the building has several storeys connected by escalators Pressure differences between the inside and outside of the building Door characteristics: if always open, if automatic door, manual door, revolving door, etc... Characteristics of the ventilation and air conditioning installation Voltage and electrical power availability Type of business, style and decoration of the premises

www.aircurtains.es

WIDE RANGE

applications
Model Kind Recommended Installation Height (*) Up to 1.8 m A Heating E P Common Applications Kiosks, Fast Food and small sized shops. Restaurants and places with usually closed door or automatic door when low pedestrian flow. Small and medium sized premises. Restaurants, shops and places with a medium and high pedestrian flow. Creation of different environment zones. Protection against dust, fumes, pollutants and insects. False ceiling installations. Isolation and sealing of smoking areas.

Minibel

Optima Recessed Optima

2.2 - 2.5 m

Windbox, Dam Recessed Windbox S WEC, REC (G only) Deco, Variwind Zen, Rund (M,G only) Windbox DX (M,G only) M Duojet (M,G only) Rotowind (M,G only) Kool (A only) G Invisair Compact (M/A only) Triojet Windbox Max L XL

2.5 - 3 m 2.8 - 3.5 m 3.2 - 4 m

Medium and large sized premises with a high pedestrian flow. Protection against dust, fumes, pollutants and insects. Cold rooms. False ceiling installations. Isolation and sealing of smoking areas.

2-3m 4-5m 6 - 11 m 5-6m

Industrial doors for large cold rooms and freezers. Medium and large sized premises with a high pedestrian flow. Industrial doors. Protection against dust, fumes, pollutants and insects. Cold rooms. False ceiling installations. Industrial doors. Loading dock. Vertical Installation to one side of the door or at each side of the door. Horizontal Installation.

(*) The maximum height of installation depends on the conditions of the premises. Contact us to clear up your queries or doubts. (A) Air Only, (E) Electrical Heating, (P) Water Coil Heating LPHW. 3

INDEX |

Air Curtains Wide Range For All Aplications

MINIBEL

Economical for openings up to 1,8 m

High pressure for commercial and large industrial doors 4 - 11 m

WINDBOX L, XL

28-29

For commercial doors 2,2 - 2,5 m

OPTIMA

Recessed installation in column or bulkhead for commercial doors 2,8 - 4 m

INVISAIR

30-31

For commercial doors 2,2 - 2,5 m recessed installation in false ceiling

RECESSED OPTIMA

Tailor made for revolving doors 2,8 - 4 m

ROTOWIND

32-33

High pressure for commercial and industrial doors 2,5 - 4 m

WINDBOX S,M,G

8-9

High velocity for cold store and freezer doors 2,5 - 4 m

KOOL

34

High pressure for commercial doors recessed installation in false ceiling 2,5 - 4 m

RECESSED WINDBOX

10-11

TRIOJET SYSTEM
Combination system with multijets large cold stores and freezers 2 - 3 m

35

ZEN

Customisable design with bespoke fasica panels for commercial doors 2,8 - 4 m

12-13

High pressure and small dimensions for commercial and industrial 2,8 - 3,5 m

COMPACT

36

RUND

14-15

VARIWIND

Decorative cylindrical for vertical or horizontal installation 2,8 - 4 m

Tailor made variable lenght VP or VW construction 2,5 - 4 m

37

DECO
Decorative with aluminium profiles for commercial doors 2,5 - 4 m

16-17

Large industrial doors, vertical or horitzontal installation 5 - 6 m

MAX

38

High pressure for commercial doors with front panel 2,5 - 4 m

DAM

18-19

POWER COEFFICIENTS
Water heated air curtains at different water temperatures

39

Low consumption technology for commercial doors 3,2 - 4 m

EC

AIR CURTAINS

20-22

Controllers and regulation Supports, valves, sensors, etc...

CONTROL, ACCESSORIES 40-41 SPECIAL OPTIONS

DUOJET

Double jet and high efficiency for commercial doors 2,8 - 4 m

23

REFERENCES, PARTNERS
Brand names and clients European distributors map

42

HEAT PUMP AIR CURTAINS

Heating and cooling low consumption technology for commercial doors 2,8 - 4 m

24-27

INSTALLATION PICTURES

Recessed, Vertical, Design, Indutrial, etc...

43

MINIBEL |
Characteristics

Air Curtains For Commercial Doors

Self-supporting casing construction made of galvanised plated steel, painted epoxy-polyester structural white colour RAL 9016. Low noise compact axial fans. E type with heating includes electrical shielded element. A type is without heating, air only. Linear blow-out jets with airfoil profiled anodized aluminium vanes. Integrated switch for ventilation and heating control. Cable connection 1,5m length, integrated. Wall support included.

Specifications
MIN 600 A 112 230~1 0,52 2800 400 9 47 1,8 MIN 600 E230 112 230~1 0,52 2800 400 2,5 230~1 10,8 19 10 47 1,8 MIN 900 A 168 230~1 0,78 2800 600 12,5 48 1,8 MIN 900 E230 168 230~1 0,78 2800 600 3,2 230~1 13,9 16 13,5 48 1,8

Power (Fans) Voltage Current Speed Airflow Mn./Mx. Power (Heating) Voltage Current Temperature Rise Weight Noise Level Maximum Height (*)
(*) Depending on installation conditions

W V A rpm m3/h kW V A C kg dB(A) m

Dimensions
18 L A 18

160

200

4xM6

45

4xM6

MIN 600 MIN 900

L 636 936

100

A 600 900

B 520 820

C 566 866

75

OPTIMA | Air Curtains For Commercial Doors


Characteristics
Self-supporting casing construction made of galvanised plated steel, painted epoxy-polyester structural white colour RAL 9016 as standard. Other colours are available on request. Low noise twisted cross-flow fans driven by a 2-speed external rotor motor. Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. P type includes water heated coil. E type includes electrical shielded element, 2 power stages with power switches included. A type is without heating, air only. Linear blow-out jet with airfoil profiled anodised aluminium vents. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Heating capacity 80/60C kW 8 12,6 16,7 Water Drop Pressure Pa 5050 5360 5230 Electrical Heating Capacity (*) kW 4/6 3,8/5,6 6/9 3,8/5,6 6/9 5,6/11,3 5,6/11,3 Electrical Heating Voltage V 400Vx3 230Vx1 400Vx3 230Vx1 230Vx1 400Vx3 230Vx1 Electrical Heating Current A 5,8/8,7 16,5/24,5 8,7/13 16,5/24,5 26/39,1 8,1/16,3 24,5/49,1 Power Fans 230V-50Hz W 40/87 40/87 40/87 40/87 64/117 64/117 64/117 64/117 64/117 80/174 80/174 80/174 80/174 Current Fans 230V-50Hz A 0,23/0,42 0,23/0,42 0,23/0,42 0,23/0,42 0,37/0,63 0,37/0,63 0,37/0,63 0,37/0,63 0,37/0,63 0,46/0,84 0,46/0,84 0,46/0,84 0,46/0,84 Noise Level (5 m) dB(A) 41/50 41/50 41/50 41/50 43/52 43/52 43/52 43/52 43/52 46/55 46/55 46/55 46/55

Model OPT 1000 A OPT 1000 P OPT 1000 E OPT 1000 E230 OPT 1500 A OPT 1500 P OPT 1500 E OPT 1500 E230-6 OPT 1500 E230-9 OPT 2000 A OPT 2000 P OPT 2000 E OPT 2000 E230

Airflow m3/h 850/1350 725/1150 850/1350 850/1350 1250/2050 1100/1750 1250/2050 1250/2050 1250/2050 1700/2700 1450/2300 1700/2700 1700/2700

Weight kg 17,5 20,5 20,5 20,5 25,5 27,5 27,5 27,5 27,5 33 37,5 42 42

Water heated pipes connection 1/2 (*) Under request other electrical heating capacities may be supplied

Dimensions
B
215

42,5 42,5 130 215

300

65

4/6 x M8

B
Control

200 60

40

35

58

78

35

4/6 x M8

36

300

L OPT 1000 OPT 1500 OPT 2000 6 1050 1550 2050

A 940 1440 1940

B 970

RECESSED OPTIMA |
Characteristics

Recessed Air Curtains For Commercial Doors

Self-supporting casing construction made of galvanised plated steel, ready to be installed recessed in a false ceiling. The inlet grille and the blow-out jet are integrated in a single aluminium frame, painted epoxy-polyester white colour RAL 9016. Low noise twisted cross-flow fans driven by a 2-speed external rotor motor. P type includes water heated coil. E type includes electrical shielded element, 2 power stages with power switches included. A type is without heating, air only. Control panel and infrared remote controller IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Heating capacity 80/60C kW 8 12,6 16,7 Water Drop Pressure Pa 5050 5360 5230 Heating Heating Capacity (*) kW 4/6 3,8/5,6 6/9 3,8/5,6 6/9 5,6/11,3 5,6/11,3 Electrical Heating Voltage V 400Vx3 230Vx1 400Vx3 230Vx1 230Vx1 400Vx3 230Vx1 Electrical Heating Current A 5,8/8,7 16,5/24,5 8,7/13 16,5/24,5 26/39,1 8,1/16,3 24,5/49,1 Power Fans 230V-50Hz W 40/87 40/87 40/87 40/87 64/117 64/117 64/117 64/117 64/117 80/174 80/174 80/174 80/174 Current Fans 230V-50Hz A 0,23/0,42 0,23/0,42 0,23/0,42 0,23/0,42 0,37/0,63 0,37/0,63 0,37/0,63 0,37/0,63 0,37/0,63 0,46/0,84 0,46/0,84 0,46/0,84 0,46/0,84 Noise Level (5 m) dB(A) 41/50 41/50 41/50 41/50 43/52 43/52 43/52 43/52 43/52 46/55 46/55 46/55 46/55

Model RO 1000 A RO 1000 P RO 1000 E RO 1000 E230 RO 1500 A RO 1500 P RO 1500 E RO 1500 E230-6 RO 1500 E230-9 RO 2000 A RO 2000 P RO 2000 E RO 2000 E230

Airflow m3/h 850/1350 725/1150 850/1350 850/1350 1250/2050 1100/1750 1250/2050 1250/2050 1250/2050 1700/2700 1450/2300 1700/2700 1700/2700

Weight kg 24 26,5 26 26 34 37,5 37,5 37,5 37,5 44,5 49 53,5 53,5

Water heated pipes connection 1/2 (*) Under request other electrical heating capacities may be supplied

Dimensions
L 31 40 396 B A B 31

259

90

Control

4/6 x M8

446 36

445

396

L RO 1000 RO 1500 RO 2000 1000 1500 2000

L1 1050 1550 2050

A 938 1438 1938

B 969 7

41

209

35

60

200

4/6 x M8

50

L1 (L+50)

209 259

130

WINDBOX S,M,G |
Characteristics

High Pressure Air Curtains For Commercial And Industrial Doors

Self-supporting casing construction made of galvanised plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Other colours or stainless steel construction are available on request. Centrifugal double-inlet fans driven by an external rotor motor with built-in thermal protection contact. Provided with 5-speed selection. Very low noise level. Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. P type includes water heated coil (2x3/4). E type includes electrical shielded element, 3 power stages with power switches included.A type is without heating, air only. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Heating capacity 80/60C kW 8,53 12,92 18,11 23,13 28,39 10,27 16,98 23,60 29,16 35,78 13,10 20,30 Water Drop Pressure 80/60C Pa 560 500 1270 2530 4440 850 750 1950 3860 6790 Heating Capacity 60/40C kW 6,85 10,80 14,46 18,10 21,47 8,72 13,86 18,58 23,18 28,65 11,31 16,72 Water Drop Pressure 60/40C Pa 2780 4250 3110 2600 3910 4250 6690 4870 4030 7150 Heating Capacity 50/40C kW 6,66 11,01 14,42 18,67 22,79 8,63 14,29 18,77 24,30 29,68 11,29 17,39 Water Drop Pressure 50/40C Pa 770 2970 1350 2690 3830 1260 4740 2160 4320 6180 2020 6770 Electrical Heating Capacity 3x400V-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 5/10/15 7,5/15/22,5 Power Fans 230V-50Hz kW 0,372 0,372 0,372 0,558 0,558 0,558 0,744 0,744 0,744 0,930 0,930 0,930 1,116 1,116 1,116 0,510 0,510 0,510 0,765 0,765 0,765 1,020 1,020 1,020 1,275 1,275 1,275 1,530 1,530 1,530 0,765 0,765 0,765 1,020 1,020 1,020 Current Fans 230V-50Hz A 1,68 1,68 1,68 2,52 2,52 2,52 3,36 3,36 3,36 4,20 4,20 4,20 5,04 5,04 5,04 2,22 2,22 2,22 3,33 3,33 3,33 4,44 4,44 4,44 5,55 5,55 5,55 6,66 6,66 6,66 3,33 3,33 3,33 4,44 4,44 4,44 Noise Level (5 m) dB(A) 53 53 53 54 54 54 55 55 55 56 56 56 57 57 57 54 54 54 55 55 55 56 56 56 57 57 57 58 58 58 55 55 55 56 56 56

Model S 1000 P S 1000 E S 1000 A S 1500 P S 1500 E S 1500 A S 2000 P S 2000 E S 2000 A S 2500 P S 2500 E S 2500 A S 3000 P S 3000 E S 3000 A M 1000 P M 1000 E M 1000 A M 1500 P M 1500 E M 1500 A M 2000 P M 2000 E M 2000 A M 2500 P M 2500 E M 2500 A M 3000 P M 3000 E M 3000 A G 1000 P G 1000 E G 1000 A G 1500 P G 1500 E G 1500 A

Airflow m3/h 1250 1300 1300 1875 1950 1950 2500 2600 2600 3125 3250 3250 3750 3900 3900 1800 1850 1850 2700 2775 2775 3600 3700 3700 4500 4625 4625 5400 5550 5550 2700 2775 2775 3600 3700 3700

Weight kg 39 41 34 58 62 50 73 80 62 79 86 66 91 99 76 39 41 34 58 62 50 73 80 62 79 86 66 91 99 76 44 46 38 64 68 55

1300 1050 -

6830 9410 -

WINDBOX S,M,G |
Heating capacity 80/60C kW 30,40 36,00 42,91 -

High Pressure Air Curtains For Commercial And Industrial Doors


Heating Capacity 60/40C kW 24,18 28,90 34,62 Water Drop Pressure 60/40C Pa 7860 6000 10070 Heating Capacity 50/40C kW 24,71 30,58 36,20 Water Drop Pressure 50/40C Pa 3540 6520 8850 Electrical Heating Capacity 3x400V-50Hz kW 10/20/30 10/20/30 10/20/30 Power Fans 230V-50Hz kW 1,530 1,530 1,530 1,785 1,785 1,785 2,040 2,040 2,040 Current Fans 230V-50Hz A 6,66 6,66 6,66 7,77 7,77 7,77 8,88 8,88 8,88 Noise Level (5 m) dB(A) 57 57 57 58 58 58 59 59 59

Model G 2000 P G 2000 E G 2000 A G 2500 P G 2500 E G 2500 A G 3000 P G 3000 E G 3000 A

Airflow m3/h 5400 5550 5550 6300 6475 6475 7200 7400 7400

Water Drop Pressure 80/60C Pa 3320 5680 9530 -

Weight kg 83 90 72 87 96 76 99 109 86

Layouts and dimensions

4/

3000

2920

1460

Free hanging mounting

3000

2920

1460

Inside ceiling surface mounting

3000

2920

1460

False ceiling invisible mounting


9

RECESSED WINDBOX S,M,G |


Characteristics

High Pressure Recessed Air Curtains For Commercial And Industrial Doors

Self-supporting casing construction made of galvanised plated steel, ready to be installed recessed in a false ceiling. The inlet grille (aluminium profile) and blow-out nozzle are integrated in a single white frame, colour RAL 9016. Other colours are available on request. Centrifugal double-inlet fans driven by an external rotor motor with built-in thermal protection contact provided with 5-speed selection. Very low noise level. P type includes water heated coil (2x3/4). E type includes electrical shielded element, 3 power stages with power switches included. A type is without heating, air only. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Water Drop Pressure 80/60C Pa 560 500 1270 2530 850 750 1950 3860 Water Drop Pressure 60/40C Pa 2780 4250 3110 2600 4250 6690 4870 4030 Water Drop Pressure 50/40C Pa 770 2970 1350 2690 1260 4740 2160 4320 Electrical Heating Capacity 3x400V-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 3/6/9 4/8/12 6/12/18 6/12/18 -

Model RS 1000 P RS 1000 E RS 1000 A RS 1500 P RS 1500 E RS 1500 A RS 2000 P RS 2000 E RS 2000 A RS 2500 P RS 2500 E RS 2500 A RM 1000 P RM 1000 E RM 1000 A RM 1500 P RM 1500 E RM 1500 A RM 2000 P RM 2000 E RM 2000 A RM 2500 P RM 2500 E RM 2500 A

Airflow m3/h 1250 1300 1300 1875 1950 1950 2500 2600 2600 3125 3250 3250 1800 1850 1850 2700 2775 2775 3600 3700 3700 4500 4625 4625

Heating Capacity 80/60C kW 8,53 12,92 18,11 23,13 10,27 16,98 23,60 29,16 -

Heating Capacity 60/40C kW 6,85 10,80 14,46 18,10 8,72 13,86 18,58 23,18 -

Heating Capacity 50/40C kW 6,66 11,01 14.42 18,67 8,63 14,29 18,77 24,30 -

Fans Power 230V-50Hz kW 0,372 0,372 0,372 0,558 0,558 0,558 0,744 0,744 0,744 0,930 0,930 0,930 0,510 0,510 0,510 0,765 0,765 0,765 1,020 1,020 1,020 1,275 1,275 1,275

Fans Current 230V-50Hz A 1,68 1,68 1,68 2,52 2,52 2,52 3,36 3,36 3,36 4,20 4,20 4,20 2,22 2,22 2,22 3,33 3,33 3,33 4,44 4,44 4,44 5,55 5,55 5,55

Noise Level (5 m) dB(A) 53 53 53 54 54 54 55 55 55 56 56 56 54 54 54 55 55 55 56 56 56 57 57 57

Weight kg 56 58 51 83 87 75 107 114 96 121 128 108 56 58 51 83 87 75 107 114 96 121 128 108

10

RECESSED WINDBOX S,M,G |


Heating Capacity 80/60C kW 13,10 20,30 30,40 36,00 Water Drop Pressure 80/60C Pa 1300 1050 3320 5680 Heating Capacity 60/40C kW 11,31 16,72 2x3/4 2x3/4 -

High Pressure Recessed Air Curtains For Commercial And Industrial Doors
Heating Capacity 50/40C kW 11,29 17,39 7860 6000 Water Drop Pressure 50/40C Pa 2020 6770 2x3/4 2x3/4 Electrical Heating Capacity 3x400V-50Hz kW 5/10/15 7,5/15/22,5 10/20/30 10/20/30 Fans Power 230V-50Hz kW 0,765 0,765 0,765 1,020 1,020 1,020 1,530 1,530 1,530 1,785 1,785 1,785 Fans Current 230V-50Hz A 3,33 3,33 3,33 4,44 4,44 4,44 6,66 6,66 6,66 7,77 7,77 7,77 Noise Level (5 m) dB(A) 55 55 55 56 56 56 57 57 57 58 58 58

Model RG 1000 P RG 1000 E RG 1000 A RG 1500 P RG 1500 E RG 1500 A RG 2000 P RG 2000 E RG 2000 A RG 2500 P RG 2500 E RG 2500 A

Airflow m3/h 2700 2775 2775 3600 3700 3700 5400 5550 5550 6300 6475 6475

Water Drop Pressure 60/40C Pa 6830 9410 24,18 28,90 -

Weight kg 61 63 55 89 93 80 117 124 106 129 138 118

Dimensions
L A

40

40 34 25

770

33

Control 6/9 x M8

312

76

38

720

310

70

770

50

260

L
Recessed Windbox 1000 Recessed Windbox 1500 Recessed Windbox 2000 Recessed Windbox 2500 1000 1500 2000 2500

L1
1050 1550 2050 2550

A
920 1420 1920 2420

1210

20

L1 (L+50)

369

297

B
710 960

11

ZEN M,G |
Characteristics

Decorative Air Curtains For Commercial Doors

Decorative air curtain in contemporary architectural style. Its minimalist and smart design integrates in any environment and we offer the option to customise, meeting our clients need. Can include personalised logos, signs, graphic designs, etc...even can incorporate clocks, lighting, etc. Front panels are anodised aluminium. Options for stainless steel and gloss, matt or brushed paint finishes. Other materials are possible as wood, metal stressed finish etc... Central structure made of zinc plated steel finished in black forge as standard. Other colours available on request. Centrifugal double-inlet fans with external rotor motors, with built-in thermal protection contact, provided with 5-speed selection. Very low noise level. P type includes water heated coil (2x3/4). E type includes electrical element with 3 power stages. A type is unheated, air only. Anodised aluminium outlet vanes, airfoil shaped, adjustable each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Heating Capacity 80/60C kW 10,52 16,14 24,22 28,66 13,10 20,30 30,40 36,03 Water Drop Pressure 80/60C Pa 890 700 2020 3750 1300 1050 3320 5700 Heating Capacity 60/40C kW 9,04 13,28 19,11 22,80 11,31 16,72 24,18 28,94 Water Drop Pressure 60/40C Pa 4450 6390 5140 3930 6850 9410 7860 6020 Heating Capacity 50/40C kW 8,87 13,54 19,38 23,85 11,29 17,39 24,71 30,58 Water Drop Pressure 50/40C Pa 1310 4300 2330 4210 2020 6770 3540 6520 Electrical Heating Capacity 3x400V-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 5/10/15 7,5/15/22,5 10/20/30 10/20/30 Fans Power 230V-50Hz kW 0,591 0,591 0,591 0,788 0,788 0,788 1,182 1,182 1,182 1,379 1,379 1,379 0,765 0,765 0,765 1,020 1,020 1,020 1,530 1,530 1,530 1,785 1,785 1,785 Fans Current 230V-50Hz A 2,58 2,58 2,58 3,44 3,44 3,44 5,16 5,16 5,16 6,02 6,02 6,02 3,33 3,33 3,33 4,44 4,44 4,44 6,66 6,66 6,66 7,77 7,77 7,77 Noise Level (5 m) dB(A) 54 54 54 55 55 55 56 56 56 57 57 57 55 55 55 56 56 56 57 57 57 58 58 58

Model ZEN M 1000 P ZEN M 1000 E ZEN M 1000 A ZEN M 1500 P ZEN M 1500 E ZEN M 1500 A ZEN M 2000 P ZEN M 2000 E ZEN M 2000 A ZEN M 2500 P ZEN M 2500 E ZEN M 2500 A ZEN G 1000 P ZEN G 1000 E ZEN G 1000 A ZEN G 1500 P ZEN G 1500 E ZEN G 1500 A ZEN G 2000 P ZEN G 2000 E ZEN G 2000 A ZEN G 2500 P ZEN G 2500 E ZEN G 2500 A

Airflow m3/h 1875 1950 1950 2500 2600 2600 3750 3900 3900 4375 4550 4550 2700 2775 2775 3600 3700 3700 5400 5550 5550 6300 6475 6475

Weight kg 37 40 32 53 58 46 71 77 62 86 94 75 40 43 36 57 62 50 78 85 69 95 103 83

12

ZEN M,G |
Dimensions

Decorative Air Curtains For Commercial Doors

291

40

70 I 55 54 44,5 L

16

473

I 1140 1544 2044 2544

A 1115 1515 2015 2515

202

291

4x M8

Zen 1000 Zen 1500 Zen 2000 Zen 2500

177 60

1220 1620 2120 2620

14,5

14,5

Finishes
Painted any RAL colour or metal Different materials: aluminium, stainless steel AISI 304 (brushed or polished), wood, glass, PVC/PES, etc. Logos, lights, clocks, signs, vinyls, patterns, etc.

44,5

floral

crocco/ leather

screen

vintage

wood

Examples of customised front panels, to meet customers needs

13

RUND |

Cylindrical Air Curtains

Characteristics
Decorative round air curtain for vertical or horizontal installation. Faceted self-supporting casing construction made of galvanised plated steel, finished in structural epoxy-polyester white RAL 9016 of silver grey RAL 9006 as stardard. Other colours or stainless steel construction are available on request. . Double-inlet centrifugal fans with external rotor motors, with built-in thermal protection contact, provided with 5-speed selection. Very low noise level. Perforated inlet grille with filter functions and easy service. It does not need prefilter. P type includes water heated coil (2x3/4). E type includes electrical shielded element, 3 power stages with power switches included. A type is without heating, air only. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Water Heating Capacity 80/60C kW 10,52 16,14 24,22 28,66 34,08 13,10 20,30 30,40 36,03 42,94 Water Drop Pressure 80/60C Pa 890 700 2020 3750 6220 1300 1050 3320 5700 9540 Water Heating Capacity 60/40C kW 9,04 13,28 19,11 22,80 27,23 11,31 16,72 24,18 28,94 34,63 Water Drop Pressure 60/40C Pa 4450 6390 5140 3930 6510 6850 9410 7860 6020 10100 Water Heating Capacity 50/40C kW 8,87 13,54 19,38 23,85 28,12 11,29 17,39 24,71 30,58 36,20 Water Drop Pressure 50/40C Pa 1310 4300 2330 4210 5620 2020 6770 3540 6520 8850 Electrical Heating Capacity 3x400V-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 5/10/15 7,5/15/22,5 10/20/30 10/20/30 10/20/30 Fans Power Input 230V-50Hz kW 0,558 0,558 0,558 0,744 0,744 0,744 1,116 1,116 1,116 1,302 1,.302 1,302 1,488 1,488 1,488 0,765 0,765 0,765 1,020 1,020 1,020 1,530 1,530 1,530 1,785 1,785 1,785 2,040 2,040 2,040 Fans Current 230V-50Hz A 2,52 2,52 2,52 3,36 3,36 3,36 5,04 5,04 5,04 5,88 5,88 5,88 6,72 6,72 6,72 3,33 3,33 3,33 4,44 4,44 4,44 6,66 6,66 6,66 7,77 7,77 7,77 8,88 8,88 8,88 Noise Level (5 m) dB(A) 54 54 54 55 55 55 56 56 56 57 57 57 58 58 58 55 55 55 56 56 56 57 57 57 58 58 58 59 59 59

Model RUND M 1000 P RUND M 1000 E RUND M 1000 A RUND M 1500 P RUND M 1500 E RUND M 1500 A RUND M 2000 P RUND M 2000 E RUND M 2000 A RUND M 2500 P RUND M 2500 E RUND M 2500 A RUND M 3000 P RUND M 3000 E RUND M 3000 A RUND G 1000 P RUND G 1000 E RUND G 1000 A RUND G 1500 P RUND G 1500 E RUND G 1500 A RUND G 2000 P RUND G 2000 E RUND G 2000 A RUND G 2500 P RUND G 2500 E RUND G 2500 A RUND G 3000 P RUND G 3000 E RUND G 3000 A

Airflow m3/h 1875 1950 1950 2500 2600 2600 3750 3900 3900 4375 4550 4550 5000 5200 5200 2700 2775 2775 3600 3700 3700 5400 5550 5550 6300 6475 6475 7200 7400 7400

Weight kg 47 49 42 71 75 63 90 97 79 101 108 88 112 119 99 52 54 46 77 81 68 100 107 89 109 118 98 119 128 108

14

RUND | Cylindrical Air Curtains


Layouts and dimensions
Vertical installation
1
453

(*)

Floor fixing points without foot


203,5

(* )
5x8,5

15

376 200 176

30

453

75

185

4
400

53

Floor fixing points with foot RUND 1000 RUND 1500 RUND 2000 RUND 2500 RUND 3000
60

60

220

430
5

430

6x

L 1025 1525 2030 2530 2980

(*) IN/OUT Water pipes connection (in water heated units) Horizontal installation

260

Ceiling fixation through threaded rods

Wall/ceiling fixation through arms

Wall/ceiling fixation through angle supports

Wall fixation through lateral arms

Floor fixation (goalpost)

15

DECO | Decorative Air Curtains For Commercial Doors


Characteristics
Structure made of aluminium profiles and galvanised plated steel panels, finished in structural epoxy-polyester white RAL 9016 or silver grey RAL 9006 as standard. Other colours are available on request. Centrifugal double-inlet fans driven by an external rotor motor with built-in thermal protection contact. Provided with 5-speed selection. Very low noise level. Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. P type includes water heated coil (2x3/4). E type includes electrical shielded element, 3 power stages with power switches included. A type is without heating, air only. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Heating Capacity 80/60C kW 8,53 12,92 18,11 23,13 10,27 16,98 23,60 29,16 13,10 20,30 30,40 36,00 Water Drop Pressure 80/60C Pa 560 500 1270 2530 850 750 1950 3860 1300 1050 3320 5680 Heating Capacity 60/40C kW 6,85 10,80 14,46 18,10 8,72 13,86 18,58 23,18 11,31 16,72 24,18 28,90 Water Drop Pressure 60/40C Pa 2780 4250 3110 2600 4250 6690 4870 4030 6830 9410 7860 6000 Heating Capacity 50/40C kW 6,66 11,01 14,42 18,67 8,63 14,29 18,77 24,30 11,29 17,39 24,71 30,58 Water Drop Pressure 50/40C Pa 770 2970 1350 2690 1260 4740 2160 4320 2020 6770 3540 6520 Electrical Heating Capacity 3x400V-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 3/6/9 4/8/12 6/12/18 6/12/18 5/10/15 7,5/15/22,5 10/20/30 10/20/30 Fans Power 230V-50Hz kW 0,372 0,372 0,372 0,558 0,558 0,558 0,744 0,744 0,744 0,930 0,930 0,930 0,510 0,510 0,510 0,765 0,765 0,765 1,020 1,020 1,020 1,275 1,275 1,275 0,765 0,765 0,765 1,020 1,020 1,020 1,530 1,530 1,530 1,785 1,785 1,785 Fans Current 230V-50Hz A 1,68 1,68 1,68 2,52 2,52 2,52 3,36 3,36 3,36 4,20 4,20 4,20 2,22 2,22 2,22 3,33 3,33 3,33 4,44 4,44 4,44 5,55 5,55 5,55 3,33 3,33 3,33 4,44 4,44 4,44 6,66 6,66 6,66 7,77 7,77 7,77 Noise Level (5 m) dB(A) 53 53 53 54 54 54 55 55 55 56 56 56 54 54 54 55 55 55 56 56 56 57 57 57 55 55 55 56 56 56 57 57 57 58 58 58

Model DS 1000 P DS 1000 E DS 1000 A DS 1500 P DS 1500 E DS 1500 A DS 2000 P DS 2000 E DS 2000 A DS 2500 P DS 2500 E DS 2500 A DM 1000 P DM 1000 E DM 1000 A DM 1500 P DM 1500 E DM 1500 A DM 2000 P DM 2000 E DM 2000 A DM 2500 P DM 2500 E DM 2500 A DG 1000 P DG 1000 E DG 1000 A DG 1500 P DG 1500 E DG 1500 A DG 2000 P DG 2000 E DG 2000 A DG 2500 P DG 2500 E DG 2500 A

Airflow m3/h 1250 1300 1300 1875 1950 1950 2500 2600 2600 3125 3250 3250 1800 1850 1850 2700 2775 2775 3600 3700 3700 4500 4625 4625 2700 2775 2775 3600 3700 3700 5400 5550 5550 6300 6475 6475

Weight kg 41 43 36 61 65 53 77 84 66 84 91 71 41 43 36 61 65 53 77 84 66 84 81 91 46 48 40 67 71 58 87 94 76 92 101 81

16

DECO | Decorative Air Curtains For Commercial Doors


Dimensions

4/

Deco 1000 Deco 1500 Deco 2000 Deco 2500

L 1000 1500 2000 2500

L1 1096 1596 2096 2596

Details

Joining two units

(*) Adjustable fixing points through guide rail

Different colour finishes


17

DAM |

High Pressure Air Curtains For Commercial And Industrial Doors

Characteristics
Self-supporting casing construction made of galvanised plated steel, finished in structural white RAL 9016 as standard. Other colours or stainless steel construction are available on request. The inlet is made behind the front panel. It does not need maintenance. Front panel with option to customise and the possibility of including personalised logos, signs, graphic designs, images, etc. Centrifugal double-inlet fans driven by an external rotor motor with built-in thermal protection contact provided with 5-speed selection. Very low noise level. P type includes water heated coil (2x3/4). E type includes electrical shielded element, 3 power stages with power switches included. A type is without heating, air only. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Heating capacity 80/60C kW 8,53 12,92 18,11 23,13 28,39 10,27 16,98 23,60 29,16 35,78 13,10 20,30 Water Drop Pressure 80/60C Pa 560 500 1270 2530 4440 850 750 1950 3860 6790 Heating Capacity 60/40C kW 6,85 10,80 14,46 18,10 21,47 8,72 13,86 18,58 23,18 28,65 11,31 16,72 Water Drop Pressure 60/40C Pa 2780 4250 3110 2600 3910 4250 6690 4870 4030 7150 6830 9410 Heating Capacity 50/40C kW 6,66 11,01 14,42 18,67 22,79 8,63 14,29 18,77 24,30 29,68 11,29 17,39 Water Drop Pressure 50/40C Pa 770 2970 1350 2690 3830 1260 4740 2160 4320 6180 2020 6770 Electrical Heating Capacity 3x400V-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 5/10/15 7,5/15/22,5 Power Fans 230V-50Hz kW 0,372 0,372 0,372 0,558 0,558 0,558 0,744 0,744 0,744 0,930 0,930 0,930 1,116 1,116 1,116 0,510 0,510 0,510 0,765 0,765 0,765 1,020 1,020 1,020 1,275 1,275 1,275 1,530 1,530 1,530 0,765 0,765 0,765 1,020 1,020 1,020 Current Fans 230V-50Hz A 1,68 1,68 1,68 2,52 2,52 2,52 3,36 3,36 3,36 4,20 4,20 4,20 5,04 5,04 5,04 2,22 2,22 2,22 3,33 3,33 3,33 4,44 4,44 4,44 5,55 5,55 5,55 6,66 6,66 6,66 3,33 3,33 3,33 4,44 4,44 4,44 Noise Level (5 m) dB(A) 53 53 53 54 54 54 55 55 55 56 56 56 57 57 57 54 54 54 55 55 55 56 56 56 57 57 57 58 58 58 55 55 55 56 56 56

Modelo DAM S 1000 P DAM S 1000 E DAM S 1000 A DAM S 1500 P DAM S 1500 E DAM S 1500 A DAM S 2000 P DAM S 2000 E DAM S 2000 A DAM S 2500 P DAM S 2500 E DAM S 2500 A DAM S 3000 P DAM S 3000 E DAM S 3000 A DAM M 1000 P DAM M 1000 E DAM M 1000 A DAM M 1500 P DAM M 1500 E DAM M 1500 A DAM M 2000 P DAM M 2000 E DAM M 2000 A DAM M 2500 P DAM M 2500 E DAM M 2500 A DAM M 3000 P DAM M 3000 E DAM M 3000 A DAM G 1000 P DAM G 1000 E DAM G 1000 A DAM G 1500 P DAM G 1500 E DAM G 1500 A

Airflow m3/h 1250 1300 1300 1875 1950 1950 2500 2600 2600 3125 3250 3250 3750 3900 3900 1800 1850 1850 2700 2775 2775 3600 3700 3700 4500 4625 4625 5400 5550 5550 2700 2775 2775 3600 3700 3700

Weight kg 43 45 38 64 68 56 81 88 70 89 96 76 103 111 88 43 45 38 64 68 56 81 88 70 89 96 76 103 111 88 48 50 42 70 74 61

1300 1050 -

18

DAM |

High Pressure Air Curtains For Commercial And Industrial Doors


Heating capacity 80/60C kW 30,40 36,00 42,91 Water Drop Pressure 80/60C Pa 3320 5680 9530 Heating Capacity 60/40C kW 24,18 28,90 34,62 Water Drop Pressure 60/40C Pa 7860 6000 10070 Heating Capacity 50/40C kW 24,71 30,58 36,20 Water Drop Pressure 50/40C Pa 3540 6520 8850 Electrical Heating Capacity 3x400V-50Hz kW 10/20/30 10/20/30 10/20/30 Power Fans 230V-50Hz kW 1,530 1,530 1,530 1,785 1,785 1,785 2,040 2,040 2,040 Current Fans 230V-50Hz A 6,66 6,66 6,66 7,77 7,77 7,77 8,88 8,88 8,88

Model DAM G 2000 P DAM G 2000 E DAM G 2000 A DAM G 2500 P DAM G 2500 E DAM G 2500 A DAM G 3000 P DAM G 3000 E DAM G 3000 A

Airflow m3/h 5400 5550 5550 6300 6475 6475 7200 7400 7400

Noise Level (5 m) dB(A) 57 57 57 58 58 58 59 59 59

Weight kg 91 98 80 97 106 86 111 121 98

Dimensions
L A

40

460

580

76

38 33

Control 4/6 x M8 129


L 1000 A 920 1420 1920 2420 2920 B 710 960 1210 1460

52

120

580

260

1500 2000 2500 3000

70

20

100

297

34

40

19

EC AIR CURTAINS | Low consumption technology air curtains EC Technology


EC technology (Electronically Commutated) combines AC and DC voltages, bringing the best of both technologies: the motor runs on a DC voltage, but with a normal AC supply. The EC motor incorporates voltage transformation within the motor. The non-rotating part of the motor (stator) is extended to make room for an electronic PCB board which includes power transformation AC to DC, as well as the controls. EC motor have no slippage losses, reducing losses and increasing efficiency versus AC motors.

EC Motor Principle
Permanent-magnet brushless DC motor within the rotor. The stator is driven by electronic switches (which replace the Carbon brushes), controlled by a microcontroller. Electronic system (hall effect sensor or software is used to recognize the rotor position). AC operated 230Vx1 or 400Vx3, valid for 50/60Hz.

Advantages and Benefits


The new Airtecnics EC Air curtains are fascinatingly efficient reducing the running cost of the ventilation up to 67% using EC instead of AC fans. Energy savings : Minimum power consumption & better efficiency than AC equivalent. Low motor temperature : for longer lifetime than AC equivalent Simplicity : Electronic & power transformation are completely integrated within the motor. High performance: Speed can be driven up to 3600rpm. Available EC Air Curtains: Windbox SMG, Wec, Rec, Deco, Kool, Recessed Windbox, Dam, Duojet, Variwind, Rund, Zen, Rotowind and Invisair.

EC vs AC Air Curtain - Energy Saving Example


How much money can I save using an EC Air curtain? Example: Door dimension: Running time: Energy cost: Selected unit: 2 m width by 3 m height 12 hours/day, 6 days/week, 50 weeks (~ 1 year) 0,17 /kW/h (EU-27 average cost) G 2000
Total Fans Power Air Curtain Price Energy Consumption Energy Cost CO2 Emissions

AC Air Curtain
1,530 2.600 5.508 936 2.203 kW /unit kW/h kg

EC Air Curtain
0,504 3.300 1.814 308 726 kW /unit kW/h kg

Difference
- 1,026 kW + 700 - 3.694 kW/h - 628 - 1.477 kg

Result: The payback periode is 1,4 years. We recover the price increase of EC air curtain in less than two years and then we start saving energy, money and reduce CO2 emissions to the enviroment.
1000 900 800 700 600 500 400 300 200 100 0
12000 10000 8000 6000 4000 2000 0 1 2 3 4 5 6 7 8 9 10 Years Savings

10000

AC

8000 7000 6000 5000 4000 3000 2000 1000 0

AC

Savings EC

EC

1 2 3 4 5 6 7 8 9 10

Years

1 Year Energy Cost


AC

10 Years Energy Cost


CO2 25000 20000
EC

AC

15000 10000 5000 0

Savings EC

1 2 3 4 5 6 7 8 9 10

Years

Payback Periode
20

10 Years CO2 Emissions

Windbox Energy Saving | Low consumption air curtains


Characteristics
Assembled with low consumption EC fans that save up to 67% of the energy without decreasing the airflow. Self-supporting casing construction made of galvanised plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Other colours or stainless steel construction are available on request. Centrifugal double-inlet fans driven by an external rotor motor with built-in thermal protection contact. Provided with 5-speed selection. Very low noise level. Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. P type includes water heated coil (2x3/4). E type includes electrical shielded element, 3 power stages with power switches included. A type is without heating, air only. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Heating Capacity 80/60C kW 12,85 18,71 28,52 35,32 42,06 Water Drop Pressure 80/60C Pa 1260 1010 2950 5500 9170 Heating Capacity 60/40C kW 11,05 16,35 23,64 28,35 33,95 Water Drop Pressure 60/40C Pa 6530 9010 7520 5810 9740 Heating Capacity 50/40C kW 11,13 17,07 24,18 29,92 35,45 Water Drop Pressure 50/40C Pa 2020 6690 3400 6300 8620 Electrical Heating Capacity 3x400V-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 Fans Power 230V-50Hz kW 0,252 0,252 0,252 0,336 0,336 0,336 0,504 0,504 0,504 0,588 0,588 0,588 0,672 0,672 0,672 Fans Current 230V-50Hz A 1,71 1,71 1,71 2,28 2,28 2,28 3,42 3,42 3,42 3,99 3,99 3,99 4,56 4,56 4,56 Noise Level (5 m) dB(A) 55 55 55 56 56 56 57 57 57 58 58 58 59 59 59

Model WEC 1000 A WEC 1000 P WEC 1000 E WEC 1500 A WEC 1500 P WEC 1500 E WEC 2000 A WEC 2000 P WEC 2000 E WEC 2500 A WEC 2500 P WEC 2500 E WEC 3000 A WEC 3000 P WEC 3000 E

Airflow m3/h 2700 2610 2700 3600 3480 3600 5400 5220 5400 6300 6090 6300 7200 6960 7200

Weight kg 38 44 46 55 64 68 72 83 90 76 87 96 86 97 106

Dimensions

4/

3000

2920

1460

21

Windbox Recessed Energy Saving | Low consumption air curtains


Characteristics
Assembled with low consumption EC fans that save up to 67% of the energy without decreasing the airflow. Self-supporting casing construction made of galvanised plated steel, ready to be installed recessed in a false ceiling. The inlet grille (aluminium profile) and blow-out nozzle are integrated in a single white frame, colour RAL 9016. Other colours are available on request. Centrifugal double-inlet fans driven by an external rotor motor with built-in thermal protection contact. Provided with 5-speed selection. Very low noise level. P type includes water heated coil (2x3/4). E type includes electrical shielded element, 3 power stages with power switches included. A type is without heating, air only. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Water Drop Pressure 80/60C Pa 1260 1010 2950 5500 Water Drop Pressure 60/40C Pa 6530 9010 7520 5810 Water Drop Pressure 50/40C Pa 2020 6690 3400 6300 Electrical Heating Capacity 3x400V-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18

Model REC 1000 A REC 1000 P REC 1000 E REC 1500 A REC 1500 P REC 1500 E REC 2000 A REC 2000 P REC 2000 E REC 2500 A REC 2500 P REC 2500 E

Airflow m3/h 2700 2610 2700 3600 3480 3600 5400 5220 5400 6300 6090 6300

Heating Capacity 80/60C kW 12,85 18,71 28,52 35,32 -

Heating Capacity 60/40C kW 11,06 16,35 23,64 28,35 -

Heating Capacity 50/40C kW 11,13 17,07 24,18 29,92 -

Fans Power 230V-50Hz kW 0,252 0,252 0,252 0,336 0,336 0,336 0,504 0,504 0,504 0,588 0,588 0,588

Fans Current 230V-50Hz A 1,71 1,71 1,71 2,28 2,28 2,28 3,42 3,42 3,42 3,99 3,99 3,99

Noise Level (5 m) dB(A) 55 55 55 56 56 56 57 57 57 58 58 58

Weight kg 55 61 63 80 89 93 106 117 124 118 129 138

Dimensions
40 B L A B 40 34 25

770

33

Control 6/9 x M8

312

76

38

720

70

L 1000 1500 2000 2500

L1 1050 1550 2050 2550

20

L1 (L+50)

369

297

A 920 1420 1920 2420

B 710 960 1210

310

770

22

50

260

DUOJET |
Characteristics

High Efficiency and Low Consumption Air Curtains For Commercial And Industrial Doors

2 outlet jets available. It reduces the energy loss as it only warms the air of the inner jet. Self-supporting casing construction made of galvanised plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Low noise centrifugal double-inlet fans driven by an external rotor motor provided with 5-speed selection. Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. P type includes water heated coils (2x3/4). E type includes electrical shielded elements, 3 power stages with power switches included. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play), included. Optional: Interface to connect to BMS.

Specifications
Water Heating Capacity 80/60C kW 6,70 11,20 16,40 21,60 8,50 14,20 20,75 27,30 Water Drop Pressure 80/60C Pa 380 420 1090 2230 620 620 1660 3410 Water Heating Capacity 60/40C kW 5,60 6,50 13,15 16,80 7,20 12,30 17,00 21,70 Water Drop Pressure 60/40C Pa 1820 3400 2640 2270 3040 5360 4140 3590 Water Heating Capacity 50/40C kW 5,35 9,62 13,07 17,26 7,03 12,59 17,13 22,56 Water Drop Pressure 50/40C Pa 520 2360 1130 2340 840 3820 1860 3780 Electrical Heating Capacity 3x400V-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 3/6/9 4/8/12 6/12/18 6/12/18 Fans Power Input 230V-50Hz kW 0,56 0,56 0,93 0,93 1,30 1,30 1,49 1,49 0,76 0,76 1,27 1,27 1,79 1,79 2,28 2,28 Fans Current 230V-50Hz A 2,50 2,50 4,20 4,20 5,85 5,85 6.82 6,82 3,33 3,33 5,55 5,55 7,77 7,77 9,99 9,99 Noise Level (5 m) dB(A) 54 54 56 56 57 57 58 58 55 55 57 57 58 58 59 59

Model DUO M 1000 P DUO M 1000 E DUO M 1500 P DUO M 1500 E DUO M 2000 P DUO M 2000 E DUO M 2500 P DUO M 2500 E DUO G 1000 P DUO G 1000 E DUO G 1500 P DUO G 1500 E DUO G 2000 P DUO G 2000 E DUO G 2500 P DUO G 2500 E

Airflow m3/h 1875 1950 3125 3250 4375 4550 5625 5850 2700 2725 4500 4625 6300 6475 8100 8325

Weight kg 64 65 87 92 111 117 138 146 69 70 94 99 121 127 151 159

Dimensions
L 480 40 B A B 40 34

450

A 920 1420 1920 2420

B 710 960 1210

318

480

76

38 33

1000 1500 2000 2500

Control

4/

51

128

90

15

23

and Cooling HEAT PUMP AIR CURTAINS | Heating Low Consumption Air Curtains

Heat Pump Technology


Heat pump is a device that uses a small amount of energy to move heat from one location to another. This system is extremely efficient because they simply transfer heat, rather than burn fuel to create it. It consists of a closed circuit through which a special fluid (refrigerant) flows. This fluid takes on a liquid or gaseous state according to temperature and pressure conditions. The circuit is composed by: compressor, condenser, expansion valve and evaporator.

Advantages and Benefits


The new Airtecnics Heat Pump Air curtains are absolutely efficient reducing the heating cost and CO2 emissions up to 70%. Very high energy efficiency ratings to save big amounts of money on your energy bill Short Payback Period thanks to very high level of energy saving Heating and cooling included in the same system (reverse cycle) Environmentally Friendly as uses such low amounts of energy Available Airtecnics Heat Pump Air Curtains: Heating/Cooling: Windbox SMGLXL, Dam, Recessed Windbox, Wec, Rec, Variwind VW and Duojet. Only Heating: Deco, Rund, Zen, Rotowind, Variwind VP and Invisair.

Heat Pump vs Electrical Air Curtain - Energy Saving Example


How much money can I save using a Heat Pump Air curtain? Example: Door dimension: Running time: Energy cost: Selected unit: COP: 2 m width by 3 m height 12 hours/day, 6 days/week, 26 weeks (~ 1/2 year) 0,17 /kW/h (EU-27 average cost) G 2000, 28kW 3,31 (Coefficient of Performance)
Total Heating Power Air Curtain Price Energy Consumption Energy Cost CO2 Emissions

Electrical Air Curtain


28 3.800 52.416 8.911 20.966 kW /unit kW/h kg

Heat Pump Air Curtain


28 11.400 15.836 2.692 6.334 kW /unit kW/h kg

Difference
0 kW + 7.600 - 36.580 kW/h - 6.219 - 14.632 kg

Result: The payback periode is 1,8 years. We recover the price increase of Heat Pump air curtain in less than two years and then we start saving energy, money and CO2 emissions to the enviroment.
10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0
100000 80000 60000 40000 20000 0 1 2 3 4 5 6 7 8 9 10 Years Savings Electrical Heated

Electrical Heated

100000 80000 70000 60000 50000 40000 30000 20000 10000 0 1 2 3 4 5

Electrical Heated

Savings Heat Pump

Heat Pump

6 7 8 9 10

Years

1 Year Energy Cost


CO2 25000 20000 15000

10 Years Energy Cost

Electrical Heated Savings Heat Pump 1 2 3 4 5 6 7 8 9 10 Years

Heat Pump

10000 5000 0

Payback Periode
24

10 Years CO2 Emisions

WINDBOX M,G DX |
Characteristics

Heat Pump Energy Saving Air Curtains Heating and Cooling For TOSHIBA Outdoor Units

Heating or Heating/Cooling energy saving heat pump air curtains: up to 70% reduction in costs and CO2 emissions (in heat/cool mode). Self-supporting casing construction made of galvanised plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Other colours or stainless steel construction are available on request. Low noise double-inlet centrifugal fans driven by an external rotor motor with builtin thermal protection contact. Provided with 5-speed selection. Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. Low turbulence discharge nozzle with double blow-out vane, airfoil shaped, adjustable from 0 to 15 each side. Includes direct expansion coil with sensors. Optional condensate water pump. Control panel and 7m of telephone cable with fast connectors type RJ45 (Plug & Play), included. DX Interface KIT with TOSHIBA programmable control. TOSHIBA Digital Inverter outdoor heat pump unit (R410A) with expansion valve.

Specifications
Heating Capacity kW 8 11,2 14 16 16 22,4 22,4 27 27 32 14 16 16 22,4 27 32 27 32 32 38,4 Heating Power kW 2,21 2,93 3,80 4,43 4,43 6,49 6,49 8,15 8,15 8,6 3,80 4,43 4,43 6,49 8,15 8,6 8,15 8,6 8,6 10,79 Heating COP 3,62 3,82 3,68 3,61 3,61 3,45 3,45 3,31 3,31 3,72 3,68 3,61 3,61 3,45 3,31 3,72 3,31 3,72 3,72 3,58 Cooling Capacity kW 6,7 10 12 14 14 20 20 23 23 28 12 14 14 20 23 28 23 28 28 34 Cooling Power kW 2,09 3,11 3,74 4,49 4,49 7,2 7,2 8,75 8,75 8,98 3,74 4,49 4,49 7,2 8,75 8,98 8,75 8,98 8,98 11,69 Cooling EER 3,21 3,22 3,21 3,12 3,12 2,78 2,78 2,63 2,63 3,12 3,21 3,12 3,12 2,78 2,63 3,12 2,63 3,12 3,12 2,95 Power Supply 1x230V 1x230V 1x230V 1x230V 1x230V 3x400V 3x400V 3x400V 3x400V 3x400V 1x230V 1x230V 1x230V 3x400V 3x400V 3x400V 3x400V 3x400V 3x400V 3x400V Power Current Fans Fans 230V-50Hz 230V-50Hz kW A 0,510 2,22 0,510 2,22 0,765 0,765 1,020 1,020 1,275 1,275 1,530 1,530 0,765 0,765 1,020 1,020 1,530 1,530 1,785 1,785 2,040 2,040 3,33 3,33 4,44 4,44 5,55 5,55 6,66 6,66 3,33 3,33 4,44 4,44 6,66 6,66 7,77 7,77 8,88 8,88 Noise Level (5 m) dB(A) 54 54 55 55 56 56 57 57 58 58 55 55 56 56 57 57 58 58 59 59

Model (*) M 1000 DX8 M 1000 DX11 M 1500 DX14 M 1500 DX16 M 2000 DX16 M 2000 DX22 M 2500 DX22 M 2500 DX27 M 3000 DX27 M 3000 DX32/2 G 1000 DX14 G 1000 DX16 G 1500 DX16 G 1500 DX22 G 2000 DX27 G 2000 DX32/2 G 2500 DX27 G 2500 DX32/2 G 3000 DX32/2 G 3000 DX38/2

Airflow m3/h 1800 1800 2700 2700 3600 3600 4500 4500 5400 5400 2700 2700 3600 3600 5400 5400 6300 6300 7200 7200

Weight kg 41 41 60 60 77 77 83 83 95 95 44 44 64 64 83 83 87 87 99 99

(*) DX is also applicable to the models: Recessed Windbox SMG, DAM, WEC and REC /2 Coil with double circuit and two outdoor units (eg. DX32/2 is composed by two units of 16kW)

TOSHIBA Digital Inverter Outdoor Units RAV-SM803AT-E RAV-SM1103AT-E RAV-SP1104AT8-E RAV-SM1403AT-E RAV-SP1404AT8-E RAV-SM1603AT-E RAV-SP1604AT8-E RAV-SM2244AT8-E RAV-SM2804AT8-E

Heating Capacity kW 8,0 11,2 11,2 14,0 14,0 16,0 16,0 22,4 27,0

Heating Power kW 2,21 2,93 2,42 3,80 3,42 4,43 4,30 6,49 8,15

SCOP COP (**) W/W 4,02 3,54 4,28 3,68 4,09 3,61 3,72 3,45 3,31

Cooling Capacity kW 6,7 10,0 10,0 12,0 12,5 14,0 14,0 20,0 23,0

Cooling Power kW 2,09 3,11 2,37 3,74 3,46 4,49 4,49 7,2 8,75

SEER EER (**) W/W 5,63 5,58 6,57 3,21 3,61 3,12 3,12 2,78 2,63

Power Supply 1x230V 1x230V 3x400V 1x230V 3x400V 1x230V 3x400V 3x400V 3x400V

Pipes Gas Liquid inch 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8 11/8 1/2 11/8 1/2

Pipes Minimum Lenght m 5 5 3 5 3 5 3 7,5 7,5

Pipes Maximum Lenght m 30 50 75 50 75 50 75 70 70

Pipes Maximum Height m 30 30 30 30 30 30 30 30 30

(**) Energy efficiency: SCOP and SEER seasonal ratio under 12kW and COP and EER over 12kW

25

WINDBOX M,G DX |
Characteristics

Heat Pump Energy Saving Air Curtains Heating and Cooling For HITACHI Outdoor Units

Heating or Heating/Cooling energy saving heat pump air curtains: up to 70% reduction in costs and CO2 emissions (in heat/cool mode). Self-supporting casing construction made of galvanised plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Other colours or stainless steel construction are available on request. Low noise double-inlet centrifugal fans driven by an external rotor motor with builtin thermal protection contact. Provided with 5-speed selection. Micro-perforated inlet grille with filter functions of easy service. It does not need prefilter. Low turbulence discharge nozzle with double anodized aluminum blow-out vane, airfoil shaped, adjustable from 0 to 15 each side. Includes direct expansion coil with sensors. Optional condensate water pump. Control panel and 7m of telephone cable with fast connectors type RJ45 (Plug & Play), included. HITACHI DX Interface KIT with expansion valve and programmable control. HITACHI Reversible DC Inverter outdoor heat pump unit (R410A).

Specifications
Heating Capacity kW 8 11,2 14 16 16 22,4 22,4 28 28 32 14 16 16 22,4 28 32 28 32 28 44,8 Heating Power kW 1,9 2,54 3,39 4,23 4,23 5,28 5,28 7,12 7,12 8,46 3,39 4,23 4,23 5,28 7,12 8,46 7,12 8,46 7,12 10,56 Heating COP 4,21 4,41 4,12 3,78 3,78 4,24 4,24 3,93 3,93 3,78 4,12 3,78 3,78 4,24 3,93 3,78 3,93 3,78 3,93 4,24 Cooling Capacity kW 7,1 10 12,5 14 14 20 20 25 25 28 12,5 14 14 20 25 28 25 28 25 40 Cooling Power kW 1,94 2,44 3,53 4,25 4,25 5,95 5,95 7,81 7,81 8,5 3,53 4,25 4,25 5,95 7,81 8,5 7,81 8,5 7,81 11,9 Cooling EER 3,66 4,10 3,54 3,29 3,29 3,36 3,36 3,2 3,2 3,29 3,54 3,29 3,29 3,36 3,2 3,29 3,2 3,29 3,2 3,36 Power Current Fans Fans 230V-50Hz 230V-50Hz kW A 230Vx1 0,510 2,22 230Vx1/400Vx3 0,510 2,22 Power Supply 230Vx1/400Vx3 230Vx1/400Vx3 230Vx1/400Vx3 400Vx3 400Vx3 400Vx3 400Vx3 400Vx3 230Vx1/400Vx3 230Vx1/400Vx3 230Vx1/400Vx3 400Vx3 400Vx3 400Vx3 400Vx3 400Vx3 400Vx3 400Vx3 0,765 0,765 1,020 1,020 1,275 1,275 1,530 1,530 0,765 0,765 1,020 1,020 1,530 1,530 1,785 1,785 2,040 2,040 3,33 3,33 4,44 4,44 5,55 5,55 6,66 6,66 3,33 3,33 4,44 4,44 5,55 5,55 6,66 6,66 8,88 8,88 Noise Level (5 m) dB(A) 54 54 55 55 56 56 57 57 58 58 55 55 56 56 57 57 58 58 59 59

Model (*) M 1000 DX8 M 1000 DX11 M 1500 DX14 M 1500 DX16 M 2000 DX16 M 2000 DX22 M 2500 DX22 M 2500 DX28 M 3000 DX28 M 3000 DX32/2 G 1000 DX14 G 1000 DX16 G 1500 DX16 G 1500 DX22 G 2000 DX28 G 2000 DX32/2 G 2500 DX28 G 2500 DX32/2 G 3000 DX28 G 3000 DX45/2

Airflow m3/h 1800 1800 2700 2700 3600 3600 4500 4500 5000 5000 2700 2700 3600 3600 5400 5400 6300 6300 7200 7200

Weight kg 41 41 60 60 77 77 83 83 95 95 44 44 64 64 83 83 87 87 99 99

(*) DX is also applicable to the models: Recessed Windbox SMG, DAM, WEC and REC /2 Coil with double circuit and two outdoor units (eg. DX32/2 is composed by two units of 16kW)

HITACHI Reversible DC Inverter Outdoor Units RAS-3HVRNME RAS-4H(V)RNME RAS-5H(V)RNME RAS-6H(V)RNME RAS-8HRNM RAS-10HRNM

Heating Capacity kW 8,0 11,2 14 16,0 22,4 28,0

Heating Power kW 1,90 2,54 3,39 4,23 5,28 7,12

COP W/W 4,21 4,41 4,12 3,78 4,24 3,93

Cooling Capacity kW 7,1 10,0 12,5 14,0 20,0 25,0

Cooling Power kW 1,94 2,44 3,53 4,25 5,95 7,81

EER W/W 3,66 4,10 3,54 3,29 3,36 3,20

Power Supply 230Vx1 230Vx1/400vX3 230Vx1/400vX3 230Vx1/400vX3 3x400V 3x400V

Pipes Gas Liquid inch 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8 1 3/8 1 1/2

Pipes Maximum Lenght m 50 70 75 75 100 100

Pipes Maximum Height m 30 30 30 30 30 30

26

WINDBOX M,G DX |
Characteristics

Heat Pump Energy Saving Air Curtains Heating and Cooling For KAYSUN Outdoor Units

Heating or Heating/Cooling energy saving heat pump air curtains: up to 70% reduction in costs and CO2 emissions (in heat/cool mode). Self-supporting casing construction made of galvanised plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Other colours or stainless steel construction are available on request. Low noise double-inlet centrifugal fans driven by an external rotor motor with builtin thermal protection contact. Provided with 5-speed selection. Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. Low turbulence discharge nozzle with double blow-out vane, airfoil shaped, adjustable from 0 to 15 each side. Includes direct expansion coil with sensors. Optional condensate water pump. Control panel and 7m of telephone cable with fast connectors type RJ45 (Plug & Play), included. DX Interface KIT with KAYSUN programmable control. KAYSUN DC Inverter outdoor heat pump unit (R410A) with expansion valve.

Specifications
Heating Capacity kW 7,62 10,55 14,65 17,00 17,00 21,10 21,10 29,30 29,30 34,00 14,65 17 17 21,10 29,30 34,00 29,30 34,00 34,00 Heating Power kW 2,09 3,31 3,90 4,50 4,50 6,62 6,62 7,8 7,8 9 3,90 4,50 4,50 6,62 7,8 9 7,8 9 9 Heating SCOP COP (**) 3,40 3,4 3,8 3,8 3,8 3,4 3,4 3,8 3,8 3,8 3,8 3,8 3,8 3,4 3,8 3,8 3,8 3,8 3,8 Cooling Capacity kW 7,03 10,55 13,48 16,12 16,12 21,10 21,10 26,96 26,96 32,23 13,48 16,12 16,12 21,10 26,96 32,23 26,96 32,23 32,23 Cooling Power kW 2,19 3,26 4,00 4,8 4,8 6,52 6,52 6,5 6,5 9,6 4,00 4,8 4,8 6,52 6,5 9,6 6,5 9,6 9,6 Cooling SEER EER (**) 5,6 5,1 3,4 3,3 3,3 5,1 5,1 3,4 3,4 3,3 3,4 3,3 3,3 5,1 3,4 3,3 3,4 3,3 3,3 Power Current Fans Fans 230V-50Hz 230V-50Hz kW A 1x230V 0,510 2,22 1x230V/3x400V 0,510 2,22 Power Supply 3x400V 3x400V 3x400V 1x230V/3x400V 1x230V/3x400V 3x400V 3x400V 3x400V 3x400V 3x400V 3x400V 1x230V/3x400V 3x400V 3x400V 3x400V 3x400V 3x400V 0,765 0,765 1,020 1,020 1,275 1,275 1,530 1,530 0,765 0,765 1,020 1,020 1,530 1,530 1,785 1,785 2,040 3,33 3,33 4,44 4,44 5,55 5,55 6,66 6,66 3,33 3,33 4,44 4,44 6,66 6,66 7,77 7,77 8,88 Noise Level (5 m) dB(A) 54 54 55 55 56 56 57 57 58 58 55 55 56 56 57 57 58 58 59

Model (*) M 1000 DX8 M 1000 DX11 M 1500 DX14 M 1500 DX17 M 2000 DX17 M 2000 DX21/2 M 2500 DX21/2 M 2500 DX29/2 M 3000 DX29/2 M 3000 DX34/2 G 1000 DX14 G 1000 DX17 G 1500 DX17 G 1500 DX21/2 G 2000 DX29/2 G 2000 DX34/2 G 2500 DX29/2 G 2500 DX34/2 G 3000 DX34/2

Airflow m3/h 1800 1800 2700 2700 3600 3600 4500 4500 5400 5400 2700 2700 3600 3600 5400 5400 6300 6300 7200

Weight kg 41 41 60 60 77 77 83 83 95 95 44 44 64 64 83 83 87 87 99

(*) DX is also applicable to the models: Recessed Windbox SMG, DAM, WEC and REC /2 Coil with double circuit and two outdoor units (eg. DX34/2 is composed by two units of 17kW)

KAYSUN DC Inverter Outdoor Units KPD-71 DVN6 KPD-105 DVN6 KPD-105 DTN6 KPD-140 DTN6 KPD-176 DTN6

Heating Capacity kW 7,62 10,55 10,55 14,65 17,00

Heating Power kW 2,09 3,31 3,31 3,9 4,5

SCOP COP (**) W/W 3,4 3,4 3,4 3,8 3,8

Cooling Capacity kW 7,03 10,55 10,55 13,48 16,12

Cooling Power kW 2,19 3,26 3,25 4 4,8

SEER EER (**) W/W 5,6 5,1 5,1 3,4 3,3

Power Supply 1x230V 1x230V 3x400V 3x400V 3x400V

Pipes Gas Liquid inch 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8

Pipes Maximum Lenght m 50 65 65 65 65

Pipes Maximum Height m 20 20 20 30 30

(**) Energy efficiency: SCOP and SEER seasonal ratio under 12kW and COP and EER over 12kW

27

WINDBOX L,XL |
Characteristics

High Pressure Air Curtains For Commercial And Industrial Doors

Self-supporting casing construction made of galvanised plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Other colours or stainless steel construction are available on request. Centrifugal double-inlet fans driven by an external rotor motor with built-in thermal protection contact. Provided with 5-speed selection. Very low noise level. Two frontal grille options. P type includes water heated coil. E type includes electrical shielded element, 3 power stages with power switches included. A type is without heating, air only. Anodised aluminium blow-out vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 10m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Heating Capacity 80/60C kW 24,40 41,00 55,70 70,20 83,50 28,02 42,69 60,87 78,75 96,89 Water Drop Pressure 80/60C Pa 1980 1050 2660 5440 9600 2540 1380 3570 7240 12880 Water Connection 80/60C 2x1 2x1 2x1 2x1 2x1 2x1 2x1 2x1 2x1 2x1 Heating Capacity 60/40C kW 18,17 28,75 39,54 50,53 63,01 22,77 36,43 50,02 63,77 79,24 Water Drop Pressure 60/40C Pa 2650 3330 3860 5050 9370 3960 5200 5960 7700 14020 Water Connection 60/40C 2x1 2x1 2x1 2x1 2x1 2x1 2x1 2x1 2x1 2x1 Electrical Heating Capacity 3x400V-50Hz kW 10/15/25 15/22,5/37,5 20/30/50 24/36/60 24/36/60 10/15//25 15/22,5/37,5 15/22,5/37,5 20/30/50 20/30/50 24/36/60 24/36/60 27,8/46,4/74,2 24/36/60 34,8/58,2/93 Fans Power 230V-50Hz kW 0,9 0,9 0,9 1,35 1,35 1,35 1,8 1,8 1,8 2,25 2,25 2,25 2,7 2,7 2,7 2,20 2,20 2,20 2,20 3,30 3,30 3,30 3,30 4,40 4,40 4,40 4,40 5,50 5,50 5,50 5,50 6,60 6,60 6,60 6,60 Fans Current 230V-50Hz A 4 4 4 6 6 6 8 8 8 10 10 10 12 12 12 9,56 9,56 9,56 9,56 14,64 14,34 14,34 14,34 19,12 19,12 19,12 19,12 23,90 23,90 23,90 23,90 28,68 28,68 28,68 28,68 Noise Level (5 m) dB(A) 56 56 56 57 57 57 59 59 59 61 61 61 62 62 62 59 59 59 59 60 60 60 60 63 63 63 63 64 64 64 64 66 66 66 66

Model L 1000 P L 1000 E L 1000 A L 1500 P L 1500 E L 1500 A L 2000 P L 2000 E L 2000 A L 2500 P L 2500 E L 2500 A L 3000 P L 3000 E L 3000 A XL 1000 P XL 1000 E XL 1000 E37 XL 1000 A XL 1500 P XL 1500 E XL 1500 E50 XL 1500 A XL 2000 P XL 2000 E XL 2000 E60 XL 2000 A XL 2500 P XL 2500 E XL 2500 E74 XL 2500 A XL 3000 P XL 3000 E XL 3000 E93 XL 3000 A

Airflow m3/h 4400 4800 4800 6600 7200 7200 8800 9600 9600 11000 12000 12000 13200 14400 14400 6400 7000 7000 7000 9600 10500 10500 10500 12800 14000 14000 14000 16000 17500 17500 17500 19200 21000 21000 21000

Weight kg 69 70 56 94 99 79 121 127 102 151 159 125 181 188 148 94 95 95 81 125 130 130 110 156 162 162 137 191 199 199 166 227 234 234 194

28

WINDBOX L,XL |
Layouts and dimensions

High Pressure Air Curtains For Commercial And Industrial Doors

4/

Free hanging mounting

Inside ceiling surface mounting

False ceiling invisible mounting

Grille Finishes

Industrial

Decorative
29

INVISAIR | Recessed Air Curtains For Commercial and Industrial Doors


Characteristics
Specially designed for applications where the body of the air curtain is to be installed inside a column or bulkhead for architectural reasons. It can be vertically or horizontally mounted. Invisair air intake and discharge grille are in the same plane so that the air flow through the unit is in a straight line. Intake into the bulkhead or column should be by a suitable grille provided by others. Two anodised aluminium adjustable lamellas, airfoil shaped, so that air discharge direction can be adjusted to 0 15 degrees either side. Structure made of galvanised plated steel finished in structural epoxy-polyester white RAL 9016 as standard. Other colours are available on request. Low noise centrifugal double-inlet fans with external rotor motors, with built-in thermal protection contact, provided with 5-speed selection. P type includes water heated coil (2x3/4). E type includes electrical element shielded element, 3 power stages with power switches included. A type is unheated, air only. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Heating Capacity 80/60C kW 16,14 24,22 28,66 34,08 20,30 30,40 36,03 42,94 Water Drop Pressure 80/60C Pa 700 2020 3750 6220 1050 3320 5700 9540 Heating Capacity 60/40C kW 13,28 19,11 22,80 27,23 16,72 24,18 28,94 34,63 Water Drop Pressure 60/40C Pa 6390 5140 3930 6510 9410 7860 6020 10100 Heating Capacity 50/40C kW 13,54 19,38 23,85 28,12 17,39 24,71 30,58 36,20 Water Drop Pressure 50/40C Pa 4300 2330 4210 5620 6770 3540 6520 8850 Electrical Heating Capacity 3x400V-50Hz kW 4/8/12 6/12/18 6/12/18 8/16/24 7,5/15/22,5 10/20/30 10/20/30 10/20/30 Fans Power 230V-50Hz kW 0,744 0,744 0,744 1,116 1,116 1,116 1,302 1,302 1,302 1,488 1,488 1,488 1,020 1,020 1,020 1,530 1,530 1,530 1,785 1,785 1,785 2,040 2,040 2,040 Fans Current 230V-50Hz A 3,36 3,36 3,36 5,04 5,04 5,04 5,88 5,88 5,88 6,72 6,72 6,72 4,44 4,44 4,44 6,66 6,66 6,66 7,77 7,77 7,77 8,88 8,88 8,88 Noise Level (5 m) dB(A) 55 55 55 56 56 56 57 57 57 58 58 58 56 56 56 57 57 57 58 58 58 59 59 59

Model IM 1500 P IM 1500 E IM 1500 A IM 2000 P IM 2000 E IM 2000 A IM 2500 P IM 2500 E IM 2500 A IM 3000 P IM 3000 E IM 3000 A IG 1500 P IG 1500 E IG 1500 A IG 2000 P IG 2000 E IG 2000 A IG 2500 P IG 2500 E IG 2500 A IG 3000 P IG 3000 E IG 3000 A

Airflow m3/h 2500 2600 2600 3750 3900 3900 4375 4550 4550 5000 5200 5200 3600 3700 3700 5400 5550 5550 6300 6475 6475 7200 7400 7400

Weight kg 63 67 55 78 86 68 86 93 73 99 107 84 69 73 60 89 96 78 94 103 83 107 117 94

30

INVISAIR | Recessed Air Curtains For Commercial and Industrial Doors


Layouts and dimensions
Min 210 Max 260

106

(*)

12,5

360

285
14
257

14

6x

Floor fixing points with foot 6x12 (bottom view)


1 2

403 318 249

334 312

360

Min 210 Max 260

L - 52

L-90

6 x M8

159 381

68

Control

(*)
50 185 50

OPTIONAL Lateral water pipes entrance (top view)

46 38 33

Foot

(*) IN/OUT Water pipes connection (in water heated units)

Installation examples

19

12,5

52,5

30

Invisair 1500 2000 2500 3000

L 1550 2055 2555 2995

A 1525 2030 2530 2970

B 726,5 1015 1265 1485

106

40

85

On top horizontal mounting

Vertical left side Installation

Vertical right side Installation

49

119 117

285

81 79

= =

= =

31

ROTOWIND | Air Curtains For Revolving Doors


Characteristics
Specially designed to be installed in all type of revolving doors. Two possible layouts, tailored dimensions. Structure made of galvanised plated steel, finished in structural epoxy-polyester white RAL 9016 as standard. Other colours are available on request. Double-inlet centrifugal fans driven by external rotor motors, with built-in thermal protection contact, provided with 5-speed selection. Very low noise level. Perforated inlet grille with filter functions and easy service. It does not need prefilter. P type includes water heated coil (2x3/4). E type includes electrical shielded element, 3 power stages with power switches included. A type is without heating, air only. Circular anodised aluminium outlet vanes, airfoil shaped. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Heating Capacity 80/60C kW 10,52 16,14 24,22 28,66 13,10 20,30 30,40 36,03 Water Drop Pressure 80/60C Pa 890 700 2020 3750 1300 1050 3320 5700 Heating Capacity 60/40C kW 9,04 13,28 19,11 22,80 11,31 16,72 24,18 28,94 Water Drop Pressure 60/40C Pa 4450 6390 5140 3930 6850 9410 7860 6020 Heating Capacity 50/40C kW 8,87 13,54 19,38 23,85 11,29 17,39 24,71 30,58 Water Drop Pressure 50/40C Pa 1310 4300 2330 4210 2020 6770 3540 6520 Electrical Heating Capacity 3x400V-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 5/10/15 7,5/15/22,5 10/20/30 10/20/30 Fans Power 230V-50Hz kW 0,558 0,558 0,558 0,744 0,744 0,744 1,116 1,116 1,116 1,302 1,302 1,302 0,765 0,765 0,765 1,020 1,020 1,020 1,530 1,530 1,530 1,785 1,785 1,785 Fans Current 230V-50Hz A 2,52 2,52 2,52 3,36 3,36 3,36 5,04 5,04 5,04 5,88 5,88 5,88 3,33 3,33 3,33 4,44 4,44 4,44 6,66 6,66 6,66 7,77 7,77 7,77 Noise Level (5 m) dB(A) 54 54 54 55 55 55 56 56 56 57 57 57 55 55 55 56 56 56 57 57 57 58 58 58

Model ROTO M 1000 P ROTO M 1000 E ROTO M 1000 A ROTO M 1500 P ROTO M 1500 E ROTO M 1500 A ROTO M 2000 P ROTO M 2000 E ROTO M 2000 A ROTO M 2500 P ROTO M 2500 E ROTO M 2500 A ROTO G 1000 P ROTO G 1000 E ROTO G 1000 A ROTO G 1500 P ROTO G 1500 E ROTO G 1500 A ROTO G 2000 P ROTO G 2000 E ROTO G 2000 A ROTO G 2500 P ROTO G 2500 E ROTO G 2500 A

Airflow m3/h 1875 1950 1950 2500 2600 2600 3750 3900 3900 4375 4550 4550 2700 2775 2775 3600 3700 3700 5400 5550 5550 6300 6475 6475

Weight kg -

32

ROTOWIND | Air Curtains For Revolving Doors


Layouts and dimensions
RotoWind air curtains are tailor-made for any kind of revolving door according to the following layouts: On top mounting False ceiling mounting

360
285
285 360

L
4/6xM8 6x12

DI
4/6xM8

DI

6x12

Fixation system

Optional decorative front cover

Fixed onto the door

Hanging from the ceiling

1. 2. 3.

RAL 9016 standard Colour from RAL palette Stainless Steel AISI 304

33

KOOL |

High Velocity Air Curtains For Cold Stores And Freezers

Characteristics
Specially designed to be installed on doors of cold stores and freezers. Self-supporting casing construction made of galvanised plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Other colours or stainless steel construction are available on request. Double-inlet centrifugal fans driven by external rotor motors, with built-in thermal protection contact, provided with 5-speed selection. Very low noise level. Also available with flat micro-perforated inlet grille, more elegant, for commercial doors where heating is not needed. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Model KS 1000 A KS 1500 A KS 2000 A KS 2500 A KS 3000 A KM 1000 A KM 1500 A KM 2000 A KM 2500 A KM 3000 A KG 1000 A KG 1500 A KG 2000 A KG 2500 A KG 3000 A Airflow m3/h 1300 1950 2600 3250 3900 1850 2775 3700 4625 5550 2775 3700 5550 6475 7400 Without heating Air only Fans power Input 230V-50Hz kW 0,372 0,558 0,744 0,930 1,116 0,510 0,765 1,020 1,275 1,530 0,765 1,020 1,530 1,785 2,040 Fans Current 230V-50Hz A 1,68 2,52 3,36 4,20 5,04 2,22 3,33 4,44 5,55 6,66 3,33 4,44 6,66 7,77 8,88 Noise level (5 m) dB(A) 53 54 55 56 57 54 55 56 57 58 55 56 57 58 59 Weight kg 29 44 53 58 63 29 44 53 58 63 33 49 63 68 73

Dimensions
340 49 40 A L

1000 1500 2000 2500 3000

920 1420 1920 2420 2920

710 960 1210 1460

40

A L

40

34

17

257

Control

340

4/6 x M8

66

18 40

60

30

193 260

260

4/6 x M8

TRIOJET |
Characteristics

Air Curtains Combination System with Multijets For Large Cold Stores And Freezers

Specially designed to be installed on big doors of industrial cold stores and freezers. System composed by two air curtains: special Duojet with plenum and Kool. The result is a combination system of 3 jets at different temperatures and different speeds. Structure support with lateral walls to cover 100% of the opening with 3 jets should be provided by others. High efficiency barrier against big amount of thermal losses due to a big temperature difference (shorter payback). Avoid mist and ice, decreasing risk of accidents. Casing construction made of galvanised plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Other colours or stainless steel construction are available on request. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Double-inlet IP 55 centrifugal fans driven by external rotor motors, with built-in thermal protection contact, provided with 5-speed selection. Very low noise level. Includes electrical shielded element, 3 power stages with power switches included. Electronics and controllers IP65. Duojet with Automatic Total Control and Kool with Air Only control, both with telephone cable Plug & Play. Optional: Interface to connect to BMS.

Specifications
Fans Power 230V-50Hz kW 2,29 3,31 4,08 Fans Current 230V-50Hz A 9,99 14,43 17,76 Electrical Heating Capacity 3x400V-50Hz kW 4/8/12 6/12/18 6/12/18 Noise level (5 m) dB(A) 60 61 62

Model TRIO 1500 TRIO 2000 TRIO 2500

Airflow m3/h 8325 12025 14800

Weight kg 182 234 275

Dimensions
450 480 340 190 450 90 60 30 260 30

35

COMPACT | High Velocity And Compact Air Curtains


Characteristics
High pressure and small dimensions air curtains. Self-supporting casing construction made of zinc plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Other colours or stainless steel construction are available on request. Double-inlet centrifugal fans with external rotor motors, with built-in thermal protection contact, provided by 5-speed selection. Very low noise level. Perforated inlet grille of big surface to reduce the energy loss at minimum. It does not need maintenance. All models are without heating, air only. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play), included. Optional: Interface to connect to BMS.

Specifications
Model COM 1000 COM 1500 COM 2000 COM 2500 Airflow m3/h 1860 2480 3720 4340 Without heating Air only Fans power 230V-50Hz kW 0,62 0,83 1,24 1,45 Fans current 230V-50Hz A 3,30 4,40 6,60 7,70 Noise level (5 m) dB(A) 52 53 54 55 Weight kg 21 32 43 55

Dimensions

4/

4/

COM 1000 COM 1500 COM 2000 COM 2500

L 1000 1500 2000 2500

36

VARIWIND | Modular, Variable Length Air Curtains


Characteristics
VP (with profiles) Designed to be tailor-made, adaptable to any customers needs. Option VP: Structure made of aluminium profiles and galvanised plated steel panels, finished white RAL 9016 as standard. Other colours are available on request. VP construction allow the service from the top and the bottom. Option VW: Self-supporting casing construction as Windbox SMG, made of galvanised plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Other colours or stainless steel construction are available on request. Double-inlet centrifugal fans driven by external rotor motors, with built-in thermal protection contact, provided with 5-speed selection. Very low noise level. P type includes water heated coil. E type includes electrical shielded element, 3 power stages with power switches included. A type is without heating, air only. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared remote control IR included. 7m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

VW (windbox construction)

Specifications
The perfomance of Variwind air curtains is the same as Windbox S,M,G. It has S, M and G types from 1000 to 3000 mm lenght. Its available unheated, water heated, electrical heated or with heat pump.

Layouts and dimensions


VariWind air curtains can be tailor-made at the request of the customers in any length from 1045 mm to 3000 mm. Variwind 1000 Variwind 1500 Variwind 2000 Variwind 2500 Standard L (mm) 1045 1545 2050 2550 Customised L (mm) 1045-1544 1545-2049 2050-2549 2550-3000

Free hanging mounting

Inside ceiling surface mounting

4/

4/

37

MAX |

Air Curtains For Industrial Doors

Characteristics
Usually installed in vertical position but can be mounted horizontally on industrial doors. Heavy casing made of double chamber, aluminium profiles and galvanised plated steel panels, finished white RAL 9016 as standard. Other colours are available on request. Axial fans driven by an external rotor motor with built-in thermal contact protection. Provided with 5-speed selection. Extremely low noise. Maintenance free. P type includes water heated coil. E type includes electrical shielded element, 3 power stages. A type is without heating, air only. Anodised aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15 each side. Control panel and infrared control IR included. 10m of telephone cable with fast connectors type RJ45 (Plug & Play). Optional: Interface to connect to BMS.

Specifications
Water heating capacity 80/60C kW 40,70 61,00 85,90 108,00 127,00 Water drop pressure 80/60C Pa 330 1280 3300 6640 11270 Water connections 80/60C 2x1 2x1 2x1 2x1 2x1 Water heating capacity 60/40C kW 34,20 53,10 74,20 93,00 104 Water drop pressure 60/40C Pa 7810 11400 9230 18430 3610 Water connections 60/40C 2x1 2x1 2x1 2x1 2x1 Electrical heating capacity 3x400V-50Hz kW 13,7/22,9/36,6 20,7/34,7/55,4 27,8/46,4/74,2 34,8/58,2/93 consult Fans power 230V-50Hz kW 0,68 0,68 0,68 1,02 1,02 1,02 1,36 1,36 1,36 1,70 1,70 1,70 2,04 2,04 2,04 Fans current 230V-50Hz A 2,96 2,96 2,96 4,44 4,44 4,44 5,92 5,92 5,92 7,40 7,40 7,40 8,88 8,88 8,88 Noise level (5 m) dB(A) 59 59 59 61 61 61 62 62 62 64 64 64 65 65 65

Model MAX 2 P MAX 2 E MAX 2 A MAX 3 P MAX 3 E MAX 3 A MAX 4 P MAX 4 E MAX 4 A MAX 5 P MAX 5 E MAX 5 A MAX 6 P MAX 6 E MAX 6 A

Airflow m3/h 7000 8000 8000 10500 12000 12000 14000 16000 16000 17500 20000 20000 21000 24000 24000

Weight kg 75 74 59 102 100 79 135 133 103 162 159 124 189 186 151

Dimensions
120

MAX 2 MAX 3 MAX 4 MAX 5 MAX 6


120

L 1234 1811 2388 2965 3542

38

140

POWER COEFFICIENTS |

Water Heated Air Curtains

Correction factors for water temperatures (S, M, G, L, XL)


The technical data tables give the nominal heat capacity for warm water coils supplied with water at 80/60C, 60/40C and 50/40C with the air inlet temperature at 15C, 18C and 20C. These tables supply the corresponding tactors for calculating the heat capacity with different air and water inlet temperatures. Water Coil 80/60 2 rows Difference 20C Temperatures 100/80 90/70 80/60 70/50 60/40 55/35 15C 100/85 90/75 80/65 70/55 60/45 50/35 10C 80/70 70/60 60/50 50/40 40/30 60/40 3 rows 20C 100/80 90/70 80/60 70/50 60/40 50/30 15C 10C 60/45 50/35 40/30 40/30 Example of heat capacity calculation: Model M 2000 P 80/60C Air inlet temperature 15C Water temperature 90/70C
HEAT CAPACITY = Nominal Power (23,6 kW) x Coefficient (1,35) = 31,86 kW

Air Inlet Temperature 15C 1,58 1,35 1,11 0,89 0,66 0,54 1,72 1,47 1,22 0,97 0,73 0,48 1,09 0,84 0,59 0,35 2,86 2,45 2,03 1,61 1,21 0,80 0,94 0,69 0,77 18C 1,53 1,27 1,04 0,82 0,59 0,47 1,64 1,40 1,14 0,90 0,66 0,40 1,28 1,02 0,77 0,52 0,27 2,71 2,30 1,89 1,48 1,08 0,67 1,22 0,82 0,57 0,62 20C 1,46 1,22 1,00 0,78 0,54 0,42 1,59 1,35 1,09 0,86 0,61 0,35 1,20 0,97 0,72 0,48 0,22 2,62 2,21 1,81 1,40 1,00 0,59 1,14 0,75 0,49 0,53 10C 15C Coil 50/40 4 rows 20C

Water Difference Temperatures 100/80 90/70 80/60 70/50 60/40 50/30 80/65 70/55 60/45 50/35 60/45 60/50 50/40 40/30

Air Inlet Temperature 15C 3,26 2,79 2,32 1,83 1,35 0,85 2,47 2,01 1,53 1,05 0,73 1,71 1,24 0,77 18C 3,11 2,64 2,17 1,69 1,21 0,68 2,34 1,86 1,39 0,91 0,66 1,57 1,10 0,62 20C 3,01 2,54 2,07 1,59 1,11 0,58 2,24 1,77 1,30 0,83 0,61 1,47 1,01 0,53

Accessories

39

CONTROL AND REGULATION


Two ranges of control panels, both designed for easy and quick Plug & Play connection, free of mistakes, by using a telephone cable with RJ45 connectors. The digital communication between the control panel and air curtain is a very reliable connection without information losses even at long distances. All control panels can be turned ON/OFF externally and have internal memory (if the power supply is cut off, the unit goes back to the selected state).

2 Speed Range
Suitable for Optima and Recessed Optima air curtains. CW-2AO-NE Only air and water control panel 2 fan speed CE-2AO-NE Electrical control panel 2 fan speed and 2 heating stages

5 Speed Range
Suitable for Windbox, Recessed Windbox, Deco, Rund, Rotowind, Variwind, Compact and Max air curtains. CA-5AW-NE Only air control panel 5 fan speed CW-5AW-NE Water control panel 5 fan speed and electro-valve switch

CE-5AW-NE Electrical control panel 5 fan speed and 3 heating stages

D-805 Hand/Auto Water control panel (Optional) Manual and automatic operating. Auxiliary functions with anti-freeze sensor, door contact and ambience thermostat.

Common Control panels


TD Digital Thermostat Modifies heat stages and fan speed depending on temperature and selected program. Only for electrical units. Interface Allows the connection to a centralized management system like BMS...

CT Total Control Suitable for all models from Optima to Max (except Minibel). Auxiliary devices: anti-freeze sensor, door contact, thermostat, etc Time programmer: 3 ON/OFF for each different day of the week. Digital display with hour, fan speed, heating stage, temperature Multilanguage display 9 languages. Manual or automatic functioning with programmable behaviours.
40

IR Control Infrared remote control. Available for all models except Minibel.

MULTIPLE CONNECTION - ACCESSORIES - SPECIAL OPTIONS


Multiple air curtain connection

Easy to manage several units using only one control panel.

Accessories
Feet, wall supports, vibration dampers

Thermostatic valve, solenoid valve, anti-freeze sensor, door contact, ambient thermostat

Telephone cable, extension adapter

Other Options
Airtecnics as an air curtains specialist can produce units with special requirements under request. Here there are some of the possibilities: External alarm signals as: unit working, heating ON, airflow switch, dirty grille, electronic overheating signal, fans overheating TK, electrical heating blocked, etc... Special water or steam coils for higher temperatures or different power than standard Tailor made electrical heating elements at desired power and power supply Electrical heated air curtains from 400Vx3 to 230Vx3 or 230Vx1 Dummies (empty air curtains) to combine with working units Industrial air curtains at 400Vx3 with the same advantages of electronic regulation 5 speed range Industrial MAX with higher volume (MAX L) Industrial MAX with explosion proof EX fans Stainless steel AISI-316 or other materials under request Special RAL colour wiht gloss or other finishes. Special BS (British Standard), Tiger Drylac, etc... Complete tailor made air curtain or our standard range customized according to client needs Please consult us for further information or other options.
41

REFERENCES - EUROPEAN DISTRIBUTORS References

European Distributors
Airtecnics has a large experience (more than 17 years producing air curtains) and exports to more than 35 countries world-wide. Be sure that Airtcnics or our worldwide distributors network will give you the right solution for any air curtains application. Find more information and our distributors list in our specialized websites
Bulgar Catalan Czech Danish Dutch English Finnish French German Greek Hungary Italian Latvian Lithuanian Norwegian Polish Portuguese Romanian Russian Serbian Slovenian Spanish Swedish Turkish www.vazdushnizavesi.com www.cortinesaire.com www.vzduchoveclony.com www.lufttaepper.com www.luchtgordijnen.com www.aircurtains.es www.ilmaverho.com www.rideauxdair.com www.luftschleieranlagen.net www.aerokourtines.com www.legfuggonyok.com www.barrieradaria.com www.gaisaaizkari.com www.orouzuolaidos.com www.luftporter.com www.kurtynapowietrzna.com www.cortinadear.com www.perdeledeaer.com www.vozdushnyezavesy.com www.vazdusnezavese.com www.zracnezavese.com www.cortinasdeaire.es www.luftridaer.com www.havaperdeleri.eu

42

www.aircurtains.es

GALLERY
Optima
Installation in a shopping center

Recessed Windbox
Designed to be installed in a false ceiling

ZEN

Exclusive design and custom finishes

Windbox
Free hanging in a big mall

Rotowind

Tailor-made for any revolving door

Invisible inbuild Column or bulkhead air curtain

Invisair

Rund

Vertical Stainless Steel design air curtain

Multiple towers on large industrial doors

Max

43

Anda mungkin juga menyukai