LMAN0008-01-EN ETG-LRP DATA SHEET

ETG-LRP Series
4 LED Remote Phosphor Linear Low Bay and High Bay Lighting

1. INTRODUCTION

Figure 1 - 2 tube LRP with reflector shown

Advanced LED Remote Phosphor (LRP) lighting provides superior efficacy, reduced glare, and even lighting output. These lighting products are designed for indoor facility lighting, ranging from 15 -60 ceilings, such as industrial or retail applications. The LRP series glass-free, long lifetime, dimmable design make it a great lighting solution in many different settings.

2. SPECIFICATIONS
Table 1 General Product and Operating Characteristics
CRI *Red Enhancement 80 90* 80 90* 80 90* 80 90* 80 90* Lumens
*estimate

Model ETG-LRP1060 ETG-LRP2160 ETG-LRP3240 ETG-LRP4320 ETG-LRP6480

CCT 5000K 5000K 5000K 5000K 5000K 5000K 5000K 5000K 5000K 5000K

Total Watts 60 60 150 150 240 240 300 300 480 480

Lumens/Watt 100 95 100 95 100 95 100 95 100 95

Replacements 4 Tube T12 150W (HID) 6 Tube T8 400W (HID) 6 Tube T5 400W (HID) 700W (HID) 700W (HID) 1000W (HID) 1000W (HID)

*6000K *5700K *15000K *14250K *24000K *22800K *30000K *28500K *48000K *45600K

10/24/2013

No part of this publication may be reproduced without the prior agreement and written permission of Horner Lighting Group, LLC. Information in this document is subject to change without notice.

Page 1 of 4

LMAN0008-01-EN ETG-LRP DATA SHEET

Table 2 Characteristics Light and Electrical Characteristics 60-480W 0-10V > 5% -40C 45C 100 277 VAC or 277-480 VAC 48V DC IP65 1 Tube 3.53 lbs., 2 Tube 7.30 lbs., 3 Tube 10.9 lbs., 4 Tube 14.6 lbs., 6 tube 21.8 lbs. Hook, Cable, or Chain. Recommend ETG-YSM-05 Y cables. 5 Years

Fixture Watts Dimming Ambient Temperature AC Power DC Power IP Rating Fixture Weight Mounting Warranty

3. PHOTOMETRICS

Figure 4 - Aisle Candela Polar Plot

Figure 3 - High Bay Candela Polar Plot

Figure 2 - Low Bay Candela Polar Plot

10/24/2013

No part of this publication may be reproduced without the prior agreement and written permission of Horner Lighting Group, LLC. Information in this document is subject to change without notice.

Page 2 of 4

LMAN0008-01-EN ETG-LRP DATA SHEET

Figure 5 - CRI Red Enhancement

4. DIMENSIONS

5. PART NUMBER OPTIONS


Choose one option from each of the following columns to specify light: Model ETG-LRP1060 1 Tube ETG-LRP2160 2 Tube ETG-LRP3240 3 Tube ETG-LRP4320 4 Tube ETG-LRP6480 6 Tube Power Supply -P1 110-227V AC -P2 277-480V AC -P3 48V DC Automation -A1 Motion Detection -A2 Ambient -A3 Ambient & Motion Color -1 5000K / 80 CRI -2 4000k / 80CRI -3 5000K / 90 CRI Red -4 4000K / 90 CRI Red

10/24/2013

No part of this publication may be reproduced without the prior agreement and written permission of Horner Lighting Group, LLC. Information in this document is subject to change without notice.

Page 3 of 4

LMAN0008-01-EN ETG-LRP DATA SHEET Choose one of the following reflector sets to come with the light fixture: Reflectors 15-30 Feet Low Bay Reflector 30-60 Feet High Bay Reflector 20-40 feet Aisle Reflector Model Number ETG-LBR1 ETG-HBR1 ETG-ABR1

6. PRECAUTIONS

WARNING
Risk of electrical shock. Disconnect power before servicing or installing product.

WARNING
Risk of injury or damage. Unit will fall if not installed properly. Follow installation instructions.

CAUTION
Risk of injury. Wear safety glasses and gloves during installation and servicing. This luminaire is designed to be used in ambient temperatures of -40C to +45C (-40F to +113F) and be mounted horizontally with the light source down as shown above. This luminaire should be installed indoors and not in areas with limited ventilation or high ambient temperatures.

Mounting Specifications
Weight: 1 Tube 3.53 lbs., 2 Tube 7.30 lbs., 3 Tube 10.9 lbs., 4 Tube 14.6 lbs., 6 tube 21.8 lbs.

Unboxing
Our packaging is designed to protect the luminaire during shipping. Please inspect to confirm it was not damaged.

Handling
Once unpacked, the luminaire can become damaged if mishandled. Do not stack luminaires after unpacking. Protect the remote phosphor plate from scratching.

7. TECHNICAL SUPPORT
Tel: (317) 916-4274 | Fax: (317) 639-4279 | Web: http://www.heapg.com | Email: techsppt@HornerETG.com

10/24/2013

No part of this publication may be reproduced without the prior agreement and written permission of Horner Lighting Group, LLC. Information in this document is subject to change without notice.

Page 4 of 4