The natural phenomena of the density difference between a hot and cold air column that creates a natural flow through a chimney is called the Chimney effect. Learn more about this in this article.
TOPICS
CAD Software Construction Technology Energy/ Power Plants Engineering Materials Fluid Machines/ Hydraulics General HVACR Machine Design Manufacturing Technology Mechatronics Robotics Sound Engineering Thermodynamics
Ads by Google
StructureVibrationDamper multitech-fr.com
Chimney Stack Expert Designer damper specialist - free evaluation
You can see the tall flue gas stacks in all the power plants. The function of the stack is to disperse the hot gases, emissions and particulates that leave the boiler to a great height. At these heights the pollutants disperse in a very large area so that ground level concentrations are within permissible levels not harmful for humans or vegetation. Chimneys where in use from the times of the Roman Empire. Chimneys and fireplaces are a common household item in countries with a cold climate. It does the dual function of removing the hot gases out of the house at the same time bringing in fresh air to the fireplace for combustion. Flue gas stacks higher than 250 meters are common nowadays for larger power plants. The tallest stack currently is 420 meters in Kazakhstan. Many factors like terrain, dispersion pattern, plume heights, adjacent tall structures, and population density determine the height of the stack. There is a natural phenomena associated with the chimney or the flue gas stack. This is the natural flow of air up the chimney. This is called the chimney or the stack effect. This effect is found not only in chimneys but also in tall buildings.
FEATURED AUTHORS
http://www.brighthub.com/engineering/mechanical/articles/29769.aspx
14.01.2011
Page 2 of 4
Where Chimney effect is in mm of water column. Chimney height is in mteres. Temperatures are in Kelvin. For a thermal power plant with a stack height of 250 meters the effect could be around 77 mm of water column. In thermal power plants the stack effect aids the Induced draft fans in removing the hot flue gases from the furnace and dispersing them at the top of the stack. In tall buildings this effect could create problems for the airconditioning system. In deserts where the outside temperatures are higher than the cool interior of the buildings the effect will be in the reverse.
www calfa net/calfabas Annonser fra Google
Tell a friend
Share
WE ALSO RECOMMEND...
ISO Technical Writing Standards Room Air Conditioning Systems that are Easy to Construct Engine Compression Testing Equipment and Technigues Writing a Hazmat Procedure What does "Traceability" mean in ISO Documentation?
Sponsored Resources
Greenhouse Gas Gas Emissions Reduce Greenhouse Carbon Emissions Greenhouse Gases Reduce Emissions
COMMENTS
26 1 2 3 NEXT >
alok bhattacharya Nov 27, 2010 10:15 AM AFBC boiler I am not getting maximum output from the plant,i.e. 7MW instead of 10 MW. Can it be because of erratic draft pattern from boiler to I/D fan? I am planning to take shutdown of plant and check complete generating section of boiler. I guess there is external air ingress into the system as such draft is not stable. Even after altering fuel feed (Coal +rice husk), I am not getting max. pressure which may causing low generation. I hope, I could explain my problem and your guidance will help me to fix the problem. You can understand the financial loss because of 3MW loss continuously. Regards, Alok Bhattacharya 27th,Nov,2010. johnzactruba Nov 25, 2010 5:26 PM reply Aman Stack effect depends depends on the temperature of the gas. If load changes and if there is gas temperature change it affects the stack effect. AS the load on the boiler increases the volume of gas flow increases, the friction loss in the stack also increases. The nett efefct (Stack effect - loss ) will be less at higher loads.
http://www.brighthub.com/engineering/mechanical/articles/29769.aspx
14.01.2011
Page 3 of 4
Aman Nov 25, 2010 10:00 AM relation b/w draft & load on boiler Sir, If load on boiler is increased, will the chimney draft affected. Hemant Sharma Nov 23, 2010 1:44 AM stack height for automobile,stack thickness what is permissible limit of outlet of variou gas,what is the permissible limit of height of stack,what is the permissible limit of thickness ,enclosure of chimeny in auto industry johnzactruba Jun 21, 2010 6:00 PM
reply GL normally the the chimney is sized such that the stack effect and the chimney losses are equal., so that at exit of ID fan the pressure is almost zero. But if the stack is not sized properly the ID Fan will have to do more work to push the gases through the stack. In these marginal aces the effect of ambient temperature will be experienced. Leakage before of the ID fan is the single biggest cause for the ID fan to go to maximum lod condition.
G L Jun 21, 2010 4:03 PM Stack Effect Would the stack effect affect the ID fan performance?
During summer time (warmer temperatures) ID fans will tend to saturate (inlet dampers 100% open) while trying to maintain furnace draft (-0.5 in H2O). We've had to lower the load to maintain the furnace in a negative draft. We've looked for air in-leakge upstream of the ID fans and have fixed a couple of cracks. Would cracks/holes downstream of the ID fans affect the stack effect or ID fan performance? Thanks!
o.p.tandon Apr 18, 2010 5:19 AM permissible value i would like to know permissible limit value of spm sox , nox in thermal power plant. Thanks sir alok bhattacharya Apr 1, 2010 4:03 AM ESP As I understand, before putting flue gases into atmosphere, it is been passed through electrostatic precipitator to catch ash/ unburnt coal particle. In fact it has become mandatory to put ESP before I/D fan by pollution board. Your comment please. Moreover I would like to know the permissible limit of NOX, SOX, Co and SPM at present senerio. jimmy yeo Mar 31, 2010 3:06 PM renewable energy have it ever been considered that stack effect be used : 1.as a free and renewable energy? the draft can certainly turn a fanblade inside the chimney to generat3 electricity? 2. for pollution control. in large cities by attaching several chimneys to every buildings sucking the fumes generated by motor vehicles to above the top of the buildings? 3. evirnmental control, to counter greenhouse effect, by drawing minute water particles generated by hypersonic vibrations peizo, into the atmosphere to create a blanket to deflect sunlight? rajesh Mar 10, 2010 3:13 AM SIGNIFICANCE OF THE NUMBERS We happen to assign a value to the effect by calculating the chimney effect. Kindly brief with regard to the industrial chimney and high rise buildings the significance of these numbers. For instance the tallest building BURJ KHALIFA- height 828m, ambient o/s temp 50 deg C in summers and int temp say 23 deg C