Use of IS 456-2000, IS-800 code books to be permitted in the examination hall.

***** Design an isolated square footing (uniform depth) for a square column with the following data. on column = 2200 kN, size of column = 450 X 450 mm. Number of bars in column = 8-20 mm diameter SBC of soil = 250 kN/ . Use M20 concrete & Fe 415 steel. Draw plan and elevation. Design the floor slab for a room of size 5 m X 3.5 m (clear dimensions) with corners held down. Live load is 3 kN/ . Floor finish = 1 kN/ . Adopt M20 grade concrete & Fe 415 steel. Draw plan and elevation of the slab.

2.

PART B (Answer any three questions, 3 X 16 marks)


3. (a) (b) What is meant by limit state of durability? Name the features that affect the durability of R.C structures. A R.C beam of size 250 X 550 mm overall depth is reinforced with 3-20 mm & at an effective cover of 40 mm. Determine the moment of resistance & uniformly superimposed load the beam can support over an effective span of 6 m. The materials used are M20 grade concrete & Fe 415 steel. What are the assumptions in the theory of design of densely reinforced beam regarding the role of compression steel? Design a rectangular R.C beam to resist the service moments of 120 kN-m from dead loads and 110 kN-m from live loads. The beam dimensions should be 250 X 625 mm and cover 25 mm with & ck = 20 N/ . 10 mm stirrups fy = 415 N/ Explain local bond stress & flexural bond stress. Design the main longitudinal steel for the following data. b = 3 00 mm, d = 500 mm, D = 550 mm, M = 60 kN-m, T = 10 kN-m, V = 40 kN use M20 concrete & Fe 415 steel. What is meant by equivalent length of a column? Explain how column behavior is affected by the effective length. A circular column is at unsupported height of 4 m and is effectively held in position at both ends and restrained against rotation at one end. If the diameter of the column is restricted to 400 mm, determine the effective length of column as well as the main steel and lateral ties required for it to carry a factored axial load of 1500 kN. Take = 20 N/ , = 415 N/ . A rectangular beam has the following data: b = 250 mm, D = 450 mm, d = 400 mm. effective span = 5 m, number of bars in tension = 3-20 mm diameter, load at service = 10 kN/m M20 concrete & Fe 415 steel. What is the short term deflection due to load? *****

4.

(a) (b)

5.

(a) (b)

6.

(a) (b)

7.

Anda mungkin juga menyukai