Anda di halaman 1dari 7

Cardkey S300 Series Modules

Product Bulletin
Code No. LIT-12011182
Issued April 18, 2006

Introduction
The S300 Series add-on reader and input/output (I/O) modules are designed to expand the quantity of portal and I/O devices controlled by CK721, CK720, or CK705 controllers. Portal devices typically consist of readers, Request to Exit (REX) devices, door contacts, and door strikes or magnetic locks. I/O devices typically consist of alarm input devices, such as sensors, and annunciation devices, such as a sounder or strobe light. Johnson Controls, Inc. offers the following reader and I/O modules: S300-RDR2 Reader module that controls two fully configured doors. See Figure 1. S300-SI8 Input module with eight supervised (4-state) inputs. S300-SIO8 Input/Output module with eight supervised (4-state) inputs and eight outputs. S300-IO8 Input/Output module with eight unsupervised (2-state) inputs and eight outputs. S300-I16 Input module with 16 unsupervised (2-state) inputs.

Features and Benefits


Support of two fully configured portals using a single reader module Supervised inputs provide 4-state monitoring Single Pole Double Throw (SPDT) relay outputs Supports RS-485 communications with controllers Easy installation in S300-XL/XS/XXS secure enclosures. Also supports stack-mounting to conserve the number of required enclosures.
REX Device (Motion Sensor)

Reader Door Contact

RDR2 Module

Door Strike DOOR 1 REX Device (Motion Sensor)

Unsupervised vs. Supervised Inputs


An unsupervised alarm input monitors two circuit conditions: alarm and secure. A supervised alarm input provides two additional states that indicate tampering to an external alarm device.
Reader Door Contact

Door Strike DOOR 2

Figure 1: S300-RDR2 Reader Module (Two Doors)

S300 Series Module Comparison Chart


Table 1: S300 Series Module Comparison Chart Specification
Number of Available Inputs Number of Available Outputs 4-State Inputs (Supervised) 2-State Inputs (Unsupervised) Number of Supported Doors (Fully Configured)

S300-SI8
8 Yes Yes -

S300-SIO8
8 8 Yes Yes -

S300-IO8
8 8 No Yes -

S300-I16
16 No Yes -

S300-RDR2
No Yes 2

Cardkey S300 Series Modules Product Bulletin

S300-RDR2 Reader Module


Each reader module has an interface for two readers. Each interface provides: Cardkey/Wiegand, one wire data interface Sensor Wiegand, two wire data interface Four rows by four columns, 16 button keypad interface Red LED or incandescent bulb reader lamp drivers Green LED or incandescent bulb reader lamp drivers +5 VDC reader power output at 20 milliamperes +12 VDC reader power output at 150 milliamperes

The S300-RDR2 also provides two door input/output interfaces each consisting of: A two-state door monitor switch input (secure = normally closed) A two-state auxiliary access or exit request switch input (normally open) A door-strike relay (SPDT) An alarm shunt relay driver (open collector)

Table 2: S300-RDR2 Components Component


J1 J2 J3 J4 J5 J6 J7 J8 SW1 System LEDs

Description
Reader 1 Connector Reader 1 Keypad Connector Reader 1 Two-Wire Wiegand Reader Interface Connector Reader 2 Connector Reader 2 Keypad Connector Reader 2 Two-Wire Wiegand Reader Interface Connector RS-485 Input RS-485 Output Determines Reader Address Indicates when data is transmitted or received and the presence of 5 and 12 VDC S300-RDR2 Firmware

U4

Figure 2: S300-RDR2 Reader Module

S300-RDR2 Power Consumption


Table 3: S300-RDR2 Power Consumption S300-RDR2
Basic Board Door Input (Secure) Aux Input (Door Unlock) Lamp Warmer Worst Case Typical 1 Door (Led Indicators)1 Typical 2 Door (Led Indicators)1 1.

5 VDC Typical (mA)


150 20 20 0 190 170 190

5 VDC Surge (mA)


300 200 20 0 520 410 520

12 VDC Typical (mA)


20 0 120 160 300 140 240

12 VDC Surge (mA)


45 0 120 160 325 165 265

Wattage (W)

4.55

2.63

Each Reader Interface provides +5VDC, +12VDC, SHUNT Output, RED Output, and GREEN Output. The current loading on these outputs must be derived from the reader manufacturers data sheet and added to the total load. Note +5VDC is current limited to operate Cardkey Readers (20 mA).

Cardkey S300 Series Modules Product Bulletin

S300-SI8 Supervised Input Module


The S300-SI8 add-on module provides: Eight four-state (open or short circuit, alarm, and secure) alarm inputs. A three-color LED input indicator for each alarm showing: Off Open Green Secure Yellow Short Red Alarm

Table 4: S300-SI8 Components Connectors


J3 J4 J6A J6B J6C J6D SW1 System LEDs

Description
RS-485 Input RS-485 Output Alarm Inputs 1 and 2 Alarm Inputs 3 and 4 Alarm Inputs 5 and 6 Alarm Inputs 7 and 8 Address Settings Indicates when data is transmitted or received and the presence of 5 and 12 VDC S300-SI8 Firmware

U1

Figure 3: S300-SI8 Input Module

S300-SI8 Power Consumption


Table 5: S300-SI8 Power Consumption S300-SI8
Basic Board Inputs (8 Secure State) Inputs (8 Short State) Worst Case Typical (8 Alarms Secure)

5VDC Typical (mA)


150 200 400 550 350

5VDC Surge (mA)


200 200 400 600 170

12VDC Typical (mA)


3 3 3 6 3

12VDC Surge (mA)


3 3 3 6 3

Wattage (W)

2.82

Cardkey S300 Series Modules Product Bulletin

S300-SIO8 Supervised Input/Output Module


The S300-SIO8 add-on module is similar to the S300IO8 module. The differences in functionality between the two modules are: The S300-SIO8 module provides eight four-state alarm inputs, which monitor open or short circuit, alarm, and secure states. The eight alarm input LEDs are three-color indicators showing: Off - Open Green - Secure Yellow - Short Red - Alarm

All other functions, including the eight output relays, are identical to the S300-IO8 module. Table 6: S300-SIO8 Components Component
J1A J1B J1C J1D J2A J2B J2C J2D J3 J4 J6A J6B J6C J6D SW1 System LEDs

Description
Output Relay 1 Connector Output Relay 2 Connector Output Relay 3 Connector Output Relay 4 Connector Output Relay 5 Connector Output Relay 6 Connector Output Relay 7 Connector Output Relay 8 Connector RS-485 Input RS-485 Output Alarm Inputs 1 and 2 Alarm Inputs 3 and 4 Alarm Inputs 5 and 6 Alarm Inputs 7 and 8 Address Settings Indicates when data is transmitted or received, and the presence of 5 and 12 VDC S300-SIO8 Firmware

U1

Figure 4: S300-SIO8 Input/Output Module

S300-SIO8 Power Consumption


Table 7: S300-SIO8 Power Consumption S300-SIO8
Basic Board Inputs (8 Secure State) Inputs (8 Short State) Outputs (8 Set State) Worst Case Typical (8 Alarms Secure) Add for Each Active Output

5VDC Typical (mA)


150 200 400 24 574 350 3

5VDC Surge (mA)


200 200 400 24 624 170 3

12VDC Typical (mA)


3 3 3 200 206 3 25

12VDC Surge (mA)


3 3 3 200 206 3 25

Wattage (W)

5.34

Cardkey S300 Series Modules Product Bulletin

S300-IO8 Unsupervised Input/Output Module


The S300-IO8 add-on module provides: Eight two-state input points Eight general purpose SPDT output relays Eight input LEDs that illuminate when each input is in alarm Eight output LEDs showing when each relay is energized

Table 8: S300-IO8 Components Component


J1A J1B J1C J1D J2A J2B J2C J2D J3 J4 J5A J5B J5C J5D SW1 System LEDs

Description
Output Relay 1 Connector Output Relay 2 Connector Output Relay 3 Connector Output Relay 4 Connector Output Relay 5 Connector Output Relay 6 Connector Output Relay 7 Connector Output Relay 8 Connector RS485 Input RS485 Output Alarm Inputs 1 and 2 Alarm Inputs 3 and 4 Alarm Inputs 5 and 6 Alarm Inputs 7 and 8 Address Settings Indicate when data is transmitted or received and the presence of 5 and 12 VDC S300-IO8 Firmware

U1

Figure 5: S300-IO8 Input/Output Module

S300-IO8 Power Consumption


Table 9: S300-IO8 Power Consumption S300-IO8
Basic Board Inputs (8 Secure State) Outputs (8 Set State) Worst Case Typical (8 Alarms Secure) Add for Each Active Output

5VDC Typical (mA)


150 40 24 214 170 3

5VDC Surge (mA)


200 40 24 264 170 3

12VDC Typical (mA)


3 3 200 206 3 25

12VDC Surge (mA)


3 3 200 206 3 25

Wattage (W)

3.54

Cardkey S300 Series Modules Product Bulletin

S300-I16 Unsupervised Input Module


The S300-I16 add-on module provides: Sixteen two-state input points Sixteen red LED indicators that illuminate when each input is in alarm

Table 10: S300-I16 Components Component


J1A J1B J1C J1D J2 J3 J4A J4B J4C J4D SW1 System LEDs

Description
Alarm Inputs 9 and 10 Alarm Inputs 11 and 12 Alarm Inputs 13 and 14 Alarm Inputs 15 and 16 RS-485 Input RS-485 Output Alarm Inputs 1 and 2 Alarm Inputs 3 and 4 Alarm Inputs 5 and 6 Alarm Inputs 7 and 8 Address Settings Indicate when data is transmitted or received and the presence of 5 and 12 VDC S300-I16 Firmware

U3

Figure 6: S300-I16 Input Module

S300-I16 Power Consumption


Table 11: S300-I16 Power Consumption S300-I16
Basic Board Inputs (16 Secure State) Worst Case Typical (4 Alarms) Typical (8 Alarms) Typical (12 Alarms) Typical (16 Alarms)

5VDC Typical (mA)


150 80 230 170 190 210 230

5VDC Surge (mA)


200 80 280 170 190 210 230

12VDC Typical (mA)


3 0 3 N/A 3 3 3

12VDC Surge (mA)


3 0 3 N/A 3 3 3

Wattage (W)

1.19

Cardkey S300 Series Modules Product Bulletin

Technical Specifications
Table 12: Technical Specifications Description
Weight Dimensions Ambient Storage Temperature Ambient Operating Temperature Relative Humidity (Operating) Relative Humidity (Non-operating) SPDT Relay Contact Rating

Ordering Information
Table 13: Ordering Information Part Number
S300-RDR2 S300-SI8 S300-SIO8 S300-IO8 S300-I16

Specification
6.6 ounces (187 grams) 5W x 5L inches (12.7W x 12.7L cm) -40 to 158F (-40 to 70C) 0 to 50F (-18 to 10C) 20 to 80%, non-condensing 5 to 95%, non-condensing 2 A @ 24 VDC

Description
Reader module that supports two fully configured doors Module with eight 4-state (supervised) inputs Module with eight 4-state (supervised) inputs and eight outputs Module with eight 2-state (unsupervised) inputs and eight outputs Module with sixteen 2-state (unsupervised) inputs

Controls Group 507 E. Michigan Street Milwaukee, WI 53202

Cardkey is a registered trademark of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2006 Johnson Controls, Inc.

Cardkey S300 Series Modules Product Bulletin


Published in U.S.A.

7
www.johnsoncontrols.com