Anda di halaman 1dari 18

Caledonian Coaxial Cables for Railway Application

www.caledonian-cables.co.uk www.addison-cables.com

Caledonian Railway Cables


www.caledonian-cables.co.uk

TABLE OF CONTENT

TABLE OF CONTENT

FR A 3 1 6 SW4 FR A 4 0 0 SW4 FR A 2 1 3 D SW4 FR A 2 1 3 URM SW4 FR A 3 0 0 2 SW4 FR A 5 9 SW4 FR A 1 7 9 SW4

2 4 6 8 10 12 14

www.caledonian-cables.co.uk COAXIAL CABLES

FRA 316 SW4


Applications
These cables are designed for flexible installations, inside and outside railway rolling stock.

Standards
DIN 5510-2

Construction
Inner conductor: Stranded silver plated copper. Insulation: Crosslink Foam PE (SPEX). Outer conductor (shield 1): Silver plated copper. Outer conductor (shield 2): Silver plated copper. Sheath: LSZH Elastomer.
LSZH Elastomer Sheath Crosslink Foam PE Insulation Stranded Silver Plated Copper Inner Conductor Silvered Copper Shield 1 Silvered Copper Shield 2

Electrical Characteristics at 20
Impedance Nominal Capacitance Minimum Insulation Resistance Inner Conductor Resistance Outer Conductor Resistance Attenuation @10MHz @50MHz @100MHz @150MHz @200MHz @300MHz @400MHz @450MHz @500MHz @600MHz @800MHz @850MHz @900MHz @950MHz @1000MHz @1800MHz @1900MHz dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m 7 17 24 30 35 44 52 56 59 66 78 81 83 86 89 127 131 pF/m M.km M/km M/km 50+/-2 94.5 100000 29.9 7.5

www.addison-cables.com

Caledonian Railway Cables


www.caledonian-cables.co.uk

COAXIAL CABLES
135 152 175 211 245 277 70.7

@2000MHz @2400MHz @3000MHz @4000MHz @5000MHz @6000MHz Velocity of propagation

dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m %

Mechanical and Thermal Properties


Minimum Bending Radius: 5mm (static) Temperature Range: -40 +105

Dimensions and Weight


Conductor Construction No/mm
7/0.18

Nominal Inner Nominal Outer Conductor Diameter Conductor Diameter mm mm


0.54 2.5

Nominal Overall Diameter mm


3.16

Nominal Weight kg/km


21

Impact Resistant

Oil Resistant

Acid&Alkaline Resistant

Highly Flexible

Zero

NF C32-070-2.1(C2) IEC 60332-1/EN 50265-2-1

Flame Retardant

NF C32-070-2.2(C1) IEC 60332-3/EN50266

Fire Retardant

IEC 60754-1/NF C20-454 EN 50267-2-1

Zero Halogen

Low Smoke Emission Low Corrosivity


IEC 61034/NFC20-902 EN 50268/NF C32-073

EN 50267-2-2/NF C32-074 IEC 60754-2/NF C20-453

Low Toxicity

COAXIAL CABLES

FRA 400 SW4


Applications
These cables are designed for flexible installations, inside and outside railway rolling stock.

Standards
DIN 5510-2

Construction
Inner conductor: Stranded silver plated copper. Insulation: Crosslink Foam PE (SPEX). Outer conductor (shield 1): Silver plated copper. Outer conductor (shield 2): Silver plated copper. Sheath: LSZH Elastomer.
LSZH Elastomer Sheath Crosslink Foam PE Insulation Stranded Silver Plated Copper Inner Conductor Silvered Copper Shield 1 Silvered Copper Shield 2

Electrical Characteristics at 20
Impedance Nominal Capacitance Minimum Insulation Resistance Inner Conductor Resistance Outer Conductor Resistance Attenuation @10MHz @50MHz @100MHz @150MHz @200MHz @300MHz @400MHz @450MHz @500MHz @600MHz @800MHz @850MHz @900MHz @950MHz dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m 5 11 16 20 23 29 34 36 38 42 50 51 53 55 pF/m M.km M/km M/km 50+/-2 94.5 100000 29.45 7.6

www.addison-cables.com

Caledonian Railway Cables


www.caledonian-cables.co.uk

COAXIAL CABLES
56 79 82 84 94 107 128 147 165 70.7

@1000MHz @1800MHz @1900MHz @2000MHz @2400MHz @3000MHz @4000MHz @5000MHz @6000MHz Velocity of propagation

dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m %

Mechanical and Thermal Properties


Minimum Bending Radius: 25mm (static) Temperature Range: -40 +105

Dimensions and Weight


Conductor Construction No/mm
19/0.2

Nominal Inner Nominal Outer Conductor Diameter Conductor Diameter mm mm


1.0 4.24

Nominal Overall Diameter mm


5.0

Nominal Weight kg/km


60

Impact Resistant

Oil Resistant

Acid&Alkaline Resistant

Highly Flexible

Zero

NF C32-070-2.1(C2) IEC 60332-1/EN 50265-2-1

Flame Retardant

NF C32-070-2.2(C1) IEC 60332-3/EN50266

Fire Retardant

IEC 60754-1/NF C20-454 EN 50267-2-1

Zero Halogen

Low Smoke Emission Low Corrosivity


IEC 61034/NFC20-902 EN 50268/NF C32-073

EN 50267-2-2/NF C32-074 IEC 60754-2/NF C20-453

Low Toxicity

COAXIAL CABLES

FRA 213D SW4


Applications
These cables are designed for flexible installations, inside and outside railway rolling stock.

Standards
DIN 5510-2

Construction
Inner conductor: Stranded silver plated copper. Insulation: Crosslink PE (PEX). Outer conductor (shield 1): Silver plated copper. Outer conductor (shield 2): Silver plated copper. Sheath: LSZH Elastomer.
LSZH Elastomer Sheath Crosslink PE Insulation Stranded Silver Plated Copper Inner Conductor Silvered Copper Shield 1 Silvered Copper Shield 2

Electrical Characteristics at 20
Impedance Nominal Capacitance Minimum Insulation Resistance Inner Conductor Resistance Outer Conductor Resistance Attenuation @10MHz @50MHz @100MHz @150MHz @200MHz @300MHz @400MHz @450MHz @500MHz @600MHz @800MHz @850MHz @900MHz @950MHz @1000MHz @1800MHz @1900MHz dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m 2 5 8 10 12 15 17 19 20 22 27 28 29 30 31 45 47 pF/m M.km M/km M/km 50+/-2 101 100000 5.8 4.43

www.addison-cables.com

Caledonian Railway Cables


www.caledonian-cables.co.uk

COAXIAL CABLES
49 55 64 79 93 106 66

@2000MHz @2400MHz @3000MHz @4000MHz @5000MHz @6000MHz Velocity of propagation

dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m %

Mechanical and Thermal Properties


Minimum Bending Radius: 50mm (static) Temperature Range: -40 +105

Dimensions and Weight


Conductor Construction No/mm
7/0.75

Nominal Inner Nominal Outer Conductor Diameter Conductor Diameter mm mm


2.25 8.7

Nominal Overall Diameter mm


10.8

Nominal Weight kg/km


202

Impact Resistant

Oil Resistant

Acid&Alkaline Resistant

Highly Flexible

Zero

NF C32-070-2.1(C2) IEC 60332-1/EN 50265-2-1

Flame Retardant

NF C32-070-2.2(C1) IEC 60332-3/EN50266

Fire Retardant

IEC 60754-1/NF C20-454 EN 50267-2-1

Zero Halogen

Low Smoke Emission Low Corrosivity


IEC 61034/NFC20-902 EN 50268/NF C32-073

EN 50267-2-2/NF C32-074 IEC 60754-2/NF C20-453

Low Toxicity

COAXIAL CABLES

FRA 213 URM SW4


Applications
These cables are designed for flexible installations, inside and outside railway rolling stock.

Standards
DIN 5510-2

Construction
Inner conductor: Plain copper. Insulation: Crosslink PE (PEX). Outer conductor: Silver plated copper braid. Sheath: LSZH Elastomer.
LSZH Elastomer Sheath Crosslink PE Insulation Plain Copper Inner Conductor Silvered Copper Outer Conductor

Electrical Characteristics at 20
Impedance Nominal Capacitance Minimum Insulation Resistance Inner Conductor Resistance Outer Conductor Resistance Attenuation @10MHz @50MHz @100MHz @150MHz @200MHz @300MHz @400MHz @450MHz @500MHz @600MHz @800MHz @850MHz @900MHz @950MHz @1000MHz @1800MHz @1900MHz @2000MHz Velocity of propagation dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m % pF/m M.km M/km M/km

50+/-2 101 100000 5.74 3.7 2 4 6 8 9 12 14 15 16 18 22 23 24 25 26 40 41 43 66

www.addison-cables.com

Caledonian Railway Cables


www.caledonian-cables.co.uk

COAXIAL CABLES

Mechanical and Thermal Properties


Minimum Bending Radius: 50mm (static) Temperature Range: -40 +105

Dimensions and Weight


Conductor Construction No/mm
7/0.75

Nominal Inner Nominal Outer Conductor Diameter Conductor Diameter mm mm


2.25 8.15

Nominal Overall Diameter mm


10.3

Nominal Weight kg/km


161

Impact Resistant

Oil Resistant

Acid&Alkaline Resistant

Highly Flexible

Zero

NF C32-070-2.1(C2) IEC 60332-1/EN 50265-2-1

Flame Retardant

NF C32-070-2.2(C1) IEC 60332-3/EN50266

Fire Retardant

IEC 60754-1/NF C20-454 EN 50267-2-1

Zero Halogen

Low Smoke Emission Low Corrosivity


IEC 61034/NFC20-902 EN 50268/NF C32-073

EN 50267-2-2/NF C32-074 IEC 60754-2/NF C20-453

Low Toxicity

COAXIAL CABLES

FRA 3002 SW4


Applications
These cables are designed for flexible installations, inside and outside railway rolling stock.

Standards
DIN 5510-2

Construction
Inner conductor: Stranded copper plated steel. Insulation: Crosslink PE (PEX). Outer conductor: Tinned copper braid. Sheath: LSZH Elastomer.
LSZH Elastomer Sheath Crosslink PE Insulation Stranded Copper Plated Steel Inner Conductor Tinned Copper Braid Outer Conductor

Electrical Characteristics at 20
Impedance Nominal Capacitance Minimum Insulation Resistance Inner Conductor Resistance Attenuation @10MHz @50MHz @100MHz @150MHz @200MHz @300MHz @400MHz @450MHz @500MHz @600MHz @800MHz @850MHz @900MHz @950MHz @1000MHz Velocity of propagation dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m % 6 14 20 25 29 36 42 45 47 52 62 64 66 68 70 66 pF/m M.km M/km 75+/-3 67 100000 236

10

www.addison-cables.com

Caledonian Railway Cables


www.caledonian-cables.co.uk

COAXIAL CABLES

Mechanical and Thermal Properties


Minimum Bending Radius: 25mm (static) Temperature Range: -40 +105

Dimensions and Weight


Conductor Construction No/mm
7/0.14

Nominal Inner Nominal Outer Conductor Diameter Conductor Diameter mm mm


0.42 2.9

Nominal Overall Diameter mm


3.7

Nominal Weight kg/km


21

Impact Resistant

Oil Resistant

Acid&Alkaline Resistant

Highly Flexible

Zero

NF C32-070-2.1(C2) IEC 60332-1/EN 50265-2-1

Flame Retardant

NF C32-070-2.2(C1) IEC 60332-3/EN50266

Fire Retardant

IEC 60754-1/NF C20-454 EN 50267-2-1

Zero Halogen

Low Smoke Emission Low Corrosivity


IEC 61034/NFC20-902 EN 50268/NF C32-073

EN 50267-2-2/NF C32-074 IEC 60754-2/NF C20-453

Low Toxicity

COAXIAL CABLES

11

FRA 59 SW4
Applications
These cables are designed for flexible installations, inside and outside railway rolling stock.

Standards
DIN 5510-2

Construction
Inner conductor: Tinned copper. Insulation: Crosslink PE (PEX). Outer conductor: Tinned copper braid. Sheath: LSZH Elastomer.
LSZH Elastomer Sheath Crosslink PE Insulation Tinned Copper Inner Conductor Tinned Copper Braid
pF/m M.km M/km M/km dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m % 75+/-3 67 100000 58 16.1 3 8 12 15 18 23 27 29 31 35 42 44 46 47 49 66

Electrical Characteristics at 20
Impedance Nominal Capacitance Minimum Insulation Resistance Inner Conductor Resistance Outer Conductor Resistance Attenuation @10MHz @50MHz @100MHz @150MHz @200MHz @300MHz @400MHz @450MHz @500MHz @600MHz @800MHz @850MHz @900MHz @950MHz @1000MHz Velocity of propagation

12

www.addison-cables.com

Caledonian Railway Cables


www.caledonian-cables.co.uk

COAXIAL CABLES

Mechanical and Thermal Properties


Minimum Bending Radius: 30mm (static) Temperature Range: -40 +105

Dimensions and Weight


Conductor Construction No/mm
7/0.22

Nominal Inner Nominal Outer Conductor Diameter Conductor Diameter mm mm


0.66 4.45

Nominal Overall Diameter mm


6.1

Nominal Weight kg/km


57

Impact Resistant

Oil Resistant

Acid&Alkaline Resistant

Highly Flexible

Zero

NF C32-070-2.1(C2) IEC 60332-1/EN 50265-2-1

Flame Retardant

NF C32-070-2.2(C1) IEC 60332-3/EN50266

Fire Retardant

IEC 60754-1/NF C20-454 EN 50267-2-1

Zero Halogen

Low Smoke Emission Low Corrosivity


IEC 61034/NFC20-902 EN 50268/NF C32-073

EN 50267-2-2/NF C32-074 IEC 60754-2/NF C20-453

Low Toxicity

COAXIAL CABLES

13

FRA 179 SW4


Applications
These cables are designed for flexible installations, inside and outside railway rolling stock.

Standards
DIN 5510-2

Construction
Inner conductor: Stranded silver plated copper clad steel. Insulation: Crosslink Foam PE (SPEX). Outer conductor: Silver plated copper. Sheath: LSZH Elastomer.
LSZH Elastomer Sheath Crosslink Foam PE Insulation SCCS Inner Conductor Silvered Copper Outer Conductor

Electrical Characteristics at 20
Impedance Nominal Capacitance Minimum Insulation Resistance Inner Conductor Resistance Outer Conductor Resistance Attenuation @50MHz @100MHz @150MHz @200MHz @250MHz @300MHz @350MHz @400MHz @450MHz @500MHz @550MHz @600MHz @650MHz @700MHz @750MHz @800MHz @850MHz dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m 16 24 30 34 39 43 47 51 54 57 61 64 67 70 72 75 78 pF/m M.km M/km M/km 75+/-3 60 100000 800.5 27.9

14

www.addison-cables.com

Caledonian Railway Cables


www.caledonian-cables.co.uk

COAXIAL CABLES
81 83 86 69.8

@900MHz @950MHz @1000MHz Velocity of propagation

dB/100m dB/100m dB/100m %

Mechanical and Thermal Properties


Minimum Bending Radius: 5mm (static) Temperature Range: -40 +105

Dimensions and Weight


Conductor Construction No/mm
7/0.1

Nominal Inner Nominal Outer Conductor Diameter Conductor Diameter mm mm


0.305 2.13

Nominal Overall Diameter mm


2.54

Nominal Weight kg/km


11.1

Impact Resistant

Oil Resistant

Acid&Alkaline Resistant

Highly Flexible

Zero

NF C32-070-2.1(C2) IEC 60332-1/EN 50265-2-1

Flame Retardant

NF C32-070-2.2(C1) IEC 60332-3/EN50266

Fire Retardant

IEC 60754-1/NF C20-454 EN 50267-2-1

Zero Halogen

Low Smoke Emission Low Corrosivity


IEC 61034/NFC20-902 EN 50268/NF C32-073

EN 50267-2-2/NF C32-074 IEC 60754-2/NF C20-453

Low Toxicity

COAXIAL CABLES

15

UNITED KINGDOM Marchants Industrial Centre, Mill Lane, Laughton, Lewes, East Sussex, BN8 6AJ, UK T e l: 44-207-4195087 Fax: 44-207-8319489 Email: sales@caledonian-cables.co.uk Website: www.caledonian-cables.co.uk HONG KONG Unit B 22/F CMA Building 64-66 Connaught Road Central Hong Kong T e l: 852-36527508 Fax: 852-35834834 Email: hk@caledonian-cables.co.uk hk@caledonian-cables.com SHANGHAI Room 3501, CITIC Square, 1168 Nanjing Xi Lu, Shanghai 200041, P.R. China T e l: 86-21-51119178 Fax: 86-21-52524616 Email: cn@caledonian-cables.co.uk shanghai@caledonian-cables.com