AC Technology ........................................................................TH2
Epic
AC Technology ...................................................................TH3
Biocor
AC Technology .............................................................................TH5
Biocor
AC Technology .............................................................................TH7
Biocor
Technology .............................................................MH15
Masters Valved Graft with Hemashield
Technology.............................................................................MH16
Accessories
Regent
AC Technology ..............................................................................VR7
Accessories
Tailor
and Attune
AC Technology ........................................................................TH2
Epic
AC Technology ...................................................................TH3
Biocor
AC Technology .............................................................................TH5
Biocor
AC Technology .............................................................................TH7
Biocor
AC Technology
Aortic Supra-Annular Stented Valves
Product Highlights
Exceptional hemodynamic performance
1
Exterior-mounted pericardial leaflets with unique suture attachment allows for
maximum leaflet excursion and large EOAs
2
Designed to provide excellent durability with the pericardial-covered stent for
tissue-to-tissue contact to reduce the risk of abrasion
Includes Linx
AC Technology
Aortic Supra-Annular Stented Valves
Product Highlights
Provides a larger stent-to-annulus ratio than Epic aortic valve
Identical in design to the Biocor
AC Technology
Aortic Stented Valves
Product Highlights
Identical in design to the Biocor
AC Technology
Mitral Stented Valves
Product Highlights
Identical in design to the Biocor
mitral valve holder provides stent deflection (ratcheting), which reduces the potential
for suture looping and maximizes visibility and access to the valve cuff
Low combined valve and holder height facilitates minimally invasive
surgical procedures
Low profile design reduces the risk of LV outflow tract obstruction
FlexFit stent reduces leaflet stress, adapts easily to annulus to enhance knot positioning,
and returns stent posts to original shape after deflection
Short 2 x 10 second rinse time
Model/Reorder
Number
Valve
Size (mm)
Tissue Annulus
Diameter (mm)
Internal
Diameter (mm)
Ventricle
Protrusion (mm)
Total
Height (mm)
E100-25M-00 25 25 23 9 16
E100-27M-00 27 27 25 9 17
E100-29M-00 29 29 27 10 19
E100-31M-00 31 31 29 10 20
E100-33M-00 33 33 31 11 20
* There is no clinical data currently available that evaluates the long-term impact of anticalcication tissue treatment in humans.
1. Mykn PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac and Cardiovasc Surg. 2009;137(1):76-81.
2. Eichinger WB, Hettich IM, Ruzicka DJ, et al. Twenty-year experience with St. Jude medical Biocor bioprosthesis in the aortic position. Ann Thorac Surg.
2008;86(4):1204-1210.
Rx Only
St. Jude Medical Stented Tissue Valves are indicated for use as a replacement for malfunctioning native or prosthetic aortic and/or mitral valves. Adverse
events potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, heart failure, hemolysis, hemolytic
anemia, hemorrhage (anticoagulant/antiplatelet-related), leak (transvalvular or paravalvular), myocardial infarction, nonstructural dysfunction (e.g., pannus,
suture, inappropriate sizing, or other), prosthesis regurgitation, stroke, structural deterioration (e.g., calcication, leaet tear, or other), thromboembolism and
valve thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term anticoagulation and/
or anti-platelet therapy should be considered in patients with dilated left atrium, a history of thrombotic events or a cardiac rhythm of atrial brillation or utter.
Please see the Instructions for Use (IFU) for a full description of indications, contraindications, side effects, precautions, warnings and Instructions for Use.
Epic, Linx, Biocor, FlexFit, ST. JUDE MEDICAL, the nine-squares symbol and MORE CONTROL. LESS RISK.
are registered and unregistered trademarks and service marks of St. Jude Medical, Inc. and its related companies.
2011 St. Jude Medical, Inc. All rights reserved.
Customer Service Number: 1.800.544.1664
Cardiac Surgery U.S. Catalog 100033292 May 2011
Internal
Diameter
Ventricular
Protrusion
Total
Height
Tissue
Annulus
Diameter
Page TH8
Tissue Heart Valves
Ordering Information
Contents: Mitral Stented Tissue Valve (1 unit per box)
Biocor
, Biocor
Technology .............................................................MH15
Masters Valved Graft with Hemashield
Technology.............................................................................MH16
Accessories
Regent
Valved Graft
with Gelweave Valsalva
Technology
Aortic Valved Grafts
Product Highlights
Patented Valsalva design mimics natural anatomy and eases
anastomotic suturing
1-3
Gelweave technology gelatin coating aids in tissue ingrowth
4
Low porosity graft enables zero pre-clotting
4
Expanded cuff designed to minimize potential for paravalvular leak
Graft length is 10 cm minimum
St. Jude Medical heart valves are MR conditional
5
1. De Paulis R, De Matteis GM, Nardi P, et al. A New Aortic Dacron Conduit for Surgical Treatment of Aortic Root Pathology. Ital Heart J. 2000 Jul;1(7):457-63.
2. De Paulis R, Bassano C, Scaffa R, et al. Bentall Producures with a Novel Valved Conduit Incorporating Sinuses of Valsalva. Surg Technol Int.
2004;12:195-200.
3. De Paulis R, De Matteis GM, Nardi P, et al. One-year Appraisal of a New Aortic Root Conduit with Sinuses of Valsalva. J Thorac Cardiovasc Surg.
2002 Jan;123(1):33-9.
4. From Manufacturers Literature: Vascutek, Ltd.
5. St. Jude Medical MRI Safety Document.
Gelweave Valsalva is a trademark of Vascutek, Ltd.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to ow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
HP, ST. JUDE MEDICAL, the nine-squares symbol and MORE CONTROL. LESS RISK. are registered
and unregistered trademarks and service marks of St. Jude Medical, Inc. and its related companies.
2011 St. Jude Medical, Inc. All rights reserved.
Customer Service Number: 1.800.544.1664
Cardiac Surgery U.S. Catalog 100033292 May 2011
Page MH16
Mechanical Heart Valves
Model/Reorder
Number
Tissue Annulus
Diameter
(mm)
Graft Inner
Diameter
(mm)
Valve Orifice
Inner Diameter
(mm)
Geometric
Orifice Area
(cm
2
)
19CAVGJ-514-00 19 20 14.7 1.63
21CAVGJ-514-00 21 22 16.7 2.06
23CAVGJ-514-00 23 24 18.5 2.55
25CAVGJ-514-00 25 28 20.4 3.09
27CAVGJ-514-00 27 30 22.3 3.67
29CAVGJ-514-00 29 32 24.1 4.41
31CAVGJ-514-00 31 34 26.0 5.18
33CAVGJ-514-00 33 34 26.0 5.18
Ordering Information
Contents: Aortic Valved Graft (1 unit per box)
Masters Valved Graft
with Hemashield
Technology
Aortic Valved Grafts
Product Highlights
Hemashield technology graft with collagen impregnation provides
uniform tissue ingrowth and biocompatibility
1
Low porosity graft requires no pre-clotting
1
No pleats at valve cuff allow for easy positioning and attachment
of coronary anastomosis
1
Graft length is 12 cm
St. Jude Medical heart valves are MR conditional
2
1. From Manufacturers Literature: MAQUET Cardiovascular.
2. St. Jude Medical MRI Safety Document.
Hemashield is a registered trademark of Maquet Cardiovascular LLC.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to ow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
HP, ST. JUDE MEDICAL, the nine-squares symbol and MORE CONTROL. LESS RISK. are registered
and unregistered trademarks and service marks of St. Jude Medical, Inc. and its related companies.
2011 St. Jude Medical, Inc. All rights reserved.
Customer Service Number: 1.800.544.1664
Cardiac Surgery U.S. Catalog 100033292 May 2011
Page MH17
Mechanical Heart Valves
Ordering Information
Contents: 7 Double-ended Aortic Sizers, 1 Valve Holder Handle and 1 Autoclave-able Tray with Cover (1 unit per box)
Regent
Mechanical Heart Valves
Aortic valve sizes 17 mm 31 mm
Mitral valve sizes 17 mm 33 mm
The cylindrical end determines the appropriate size of the annulus
Malleable nitinol sizer and holder handle can be bent in any direction
up to 90 degrees without degradation
Sizer and holder handle return to original straight shape during sterilization
Model/Reorder
Number Description
905 Sizer Set, Complete
905-HH Valve Holder Handle
905-MHH Mitral Valve Holder Handle
905-RHH Rigid Valve Holder Handle
A-RHR
Replacement Aortic Masters Series Valve Holder/Rotators
Sizes 19 mm 31 mm
M-RHR
Replacement Mitral Masters Series Valve Holder/Rotators
Sizes 19 mm 37 mm
AHP-RHR
Replacement Aortic Masters HP Valve Holder/Rotators
Sizes 17 mm 27 mm
LT100 Mechanical Valve Leaet Tester
Ordering Information
Contents: 6 Double-ended Sizers, 3 Single-ended Sizers, 1 Valve Holder Handle and 1 Autoclavable Tray with Cover
(1 unit per box)
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to ow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
HP, ST. JUDE MEDICAL, the nine-squares symbol and MORE CONTROL. LESS RISK. are registered
and unregistered trademarks and service marks of St. Jude Medical, Inc. and its related companies.
2011 St. Jude Medical, Inc. All rights reserved.
Customer Service Number: 1.800.544.1664
Cardiac Surgery U.S. Catalog 100033292 May 2011
Valve Repair
Page VR1
Valve Repair Table of Contents
Valve Repair
Flexible Rings and Band
Attune
AC Technology ..............................................................................VR7
Accessories
Tailor
and Attune
Pericardial Patch
with EnCap
AC Technology
Pericardial Patch
Product Highlights
Flexible and durable to provide enhanced biocompatibility and lasting performance
1-3
Bovine pericardium provides improved handling and suturability compared
with synthetic patches
4
Anti-calcification treatment enhances tissue healing, biocompatibility and long-term
tissue stability
1*
Thinner patch available to accommodate pediatric applications
5
Soft, pliable tissue conforms to the anatomy and easily sutures into place
Ready-to use, rinseless preparation saves time during procedures
*There is no clinical data currently available which evaluates the long-term impact of anticalcication treatment in humans.
1. Frater RWM, Seifter E, Liao K, et al. Anticalcication, proendothelial, and anti-inammatory effect of post-aldehyde polyol treatment of bioprosthetic material.
In: Gabbay S, Wheatley DJ (eds.). Advances in Anticalcic and Antidegenerative Treatment of Heart Valve Bioprostheses. Austin, TX: Silent Partners Inc;
1997:105-14.
2. Frater RWM, Liao K, Seifter E. Stentless chordally supported mitral bioprosthetic valve. In: Gabbay S, Frater RWM (eds.) New Horizons and the Future of Heart
Valve Bioprostheses. Austin, TX: Silent Partners Inc; 1994:103-19.
3. Hoffman D, Gong G, Liao K, et al. Spontaneous host endothelial growth on bioprostheses. Circulation. 1992;86[suppl II]:II-75-II-79.
4. Crawford FA Jr, Sade RM, Spinale F. Bovine pericardium for correction of congenital heart defects. Ann Thorac Surg. 1986;41(6):602-5.
5. Hopkins, et. al. Surgical Patch Closure of Atrial Septal Defects. Ann Thorac Surg. 2001;77-2144-50.
EnCap is a trademark of Glycar, Inc.
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential
adverse events, and directions for use.
ST. JUDE MEDICAL, the nine-squares symbol and MORE CONTROL. LESS RISK. are registered
and unregistered trademarks and service marks of St. Jude Medical, Inc. and its related companies.
2011 St. Jude Medical, Inc. All rights reserved.
Customer Service Number: 1.800.544.1664
Cardiac Surgery U.S. Catalog 100033292 June 2011
Model/Reorder
Number
Patch Size
(cm)
Nominal Thickness
(mm)
C0205 2 x 5 0.20 0.40
C0405 4 x 5 0.150.25
C0510 5 x 10 0.20 0.40
C0914 9 x 14 0.20 0.40
Page VR8
Valve Repair
Tailor
ring
Sizes 25 mm 35 mm
Malleable nitinol sizer and holder handle can be bent in any direction up to
90 degrees without degradation
Ordering Information
Contents: 6 Sizers, 1 Malleable Holder Handle, 1 Extension Handle and 1 Autoclavable Tray and Cover
Model/Reorder
Number Description
TAR-505 Tailor Flexible Ring Set, Complete
HH-05 Replacement Holder Handle
EX-05 Replacement Extension Handle
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential
adverse events, and directions for use.
Tailor, Attune, ST. JUDE MEDICAL, the nine-squares symbol and MORE CONTROL. LESS RISK. are registered
and unregistered trademarks and service marks of St. Jude Medical, Inc. and its related companies.
2011 St. Jude Medical, Inc. All rights reserved.
Customer Service Number: 1.800.544.1664
Cardiac Surgery U.S. Catalog 100033292 May 2011
Page VR9
Valve Repair
Ordering Information
Contents: 6 Sizers, 1 Malleable Holder Handle, 1 Extension Handle and 1 Autoclavable Tray and Cover
SJM
and Attune
LP Ablation Device
Epicor
LP
and UltraWand
LP ablation
device selection
Locking mechanism attaches the introducer / sizer to the UltraCinch LP device,
facilitating smooth introduction and proper placement of the ablation array around
the heart
Soft atraumatic tip of the introducer / sizer promotes smooth device placement
Suture snares and tourniquets help hold the UltraCinch LP device securely in place
during ablation to ensure creation of a contiguous, circular lesion
Model/Reorder
Number
LP-PAS-1
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications,
contraindications, warnings, precautions, potential adverse events, and directions for use.
Epicor, UltraCinch, UltraWand, ST. JUDE MEDICAL, the nine-squares symbol and MORE CONTROL. LESS RISK.
are registered and unregistered trademarks and service marks of St. Jude Medical, Inc. and its related companies.
2011 St. Jude Medical, Inc. All rights reserved.
Customer Service Number: 1.800.544.1664
Cardiac Surgery U.S. Catalog 100033292 May 2011
Page CA7
Cardiac Ablation
Ordering Information
Contents: LP Oblique Introducer (1 unit per box)
LP Oblique Introducer
Epicor
LP ablation device
Lack of injection ports reduces the potential for air entrapment
Supplied by Alaris
Products*
Model/Reorder
Number
Length
(cm)
IVS-UC 264
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications,
contraindications, warnings, precautions, potential adverse events, and directions for use.
*Alaris is a registered or unregistered trademark of Cardinal Health
Epicor, UltraCinch, ST. JUDE MEDICAL, the nine-squares symbol and MORE CONTROL. LESS RISK. are
registered and unregistered trademarks and service marks of St. Jude Medical, Inc. and its related companies.
2011 St. Jude Medical, Inc. All rights reserved.
Customer Service Number: 1.800.544.1664
Cardiac Surgery U.S. Catalog 100033292 May 2011
Page NI1
Cardiac Surgery Catalog Reorder Number Index
Tissue Heart Valves
Reorder Number Page Number
B1000 TH8
B1000-H TH8
B100-21A-00 TH5
B100-23A-00 TH5
B100-25A-00 TH5
B100-25M-00 TH7
B100-27A-00 TH5
B100-27M-00 TH7
B100-29A-00 TH5
B100-29M-00 TH7
B100-31M-00 TH7
B100-33M-00 TH7
BSP100-19 TH3
BSP100-21 TH3
BSP100-23 TH3
BSP100-25 TH3
BSP100-27 TH3
Reorder Number Page Number
E100-21A-00 TH4
E100-23A-00 TH4
E100-25A-00 TH4
E100-25M-00 TH6
E100-27A-00 TH4
E100-27M-00 TH6
E100-29A-00 TH4
E100-29M-00 TH6
E100-31M-00 TH6
E100-33M-00 TH6
ESP100-19-00 TH2
ESP100-21-00 TH2
ESP100-23-00 TH2
ESP100-25-00 TH2
ESP100-27-00 TH2
EX-05 TH8
Mechanical Heart Valves
Reorder Number Page Number
905 MH18
907 MH17
17AEHPJ-505 MH6
17AFHPJ-505 MH5
17AHPJ-505 MH4
17MHPJ-505 MH10
19AECJ-502 MH8
19AEHPJ-505 MH6
19AFHPJ-505 MH5
19AGFN-756 MH3
19AGN-751 MH2
19AHPJ-505 MH4
19AJ-501 MH7
19ATJ-503 MH9
19CAVGJ-514-00 MH16
19MECJ-502 MH12
19METJ-504 MH14
19MHPJ-505 MH10
19MJ-501 MH11
19MTJ-503 MH13
19VAVGJ-515 MH15
21AECJ-502 MH8
21AEHPJ-505 MH6
21AFHPJ-505 MH5
21AGFN-756 MH3
21AGN-751 MH2
21AHPJ-505 MH4
21AJ-501 MH7
21ATJ-503 MH9
21CAVGJ-514-00 MH16
Reorder Number Page Number
21MECJ-502 MH12
21METJ-504 MH14
21MHPJ-505 MH10
21MJ-501 MH11
21MTJ-503 MH13
21VAVGJ-515 MH15
23AECJ-502 MH8
23AEHPJ-505 MH6
23AFHPJ-505 MH5
23AGFN-756 MH3
23AGN-751 MH2
23AHJP-505 MH4
23AJ-501 MH7
23ATJ-503 MH9
23CAVGJ-514-00 MH16
23MECJ-502 MH12
23METJ-504 MH14
23MHPJ-505 MH10
23MJ-501 MH11
23MTJ-503 MH13
23VAVGJ-515 MH15
25AECJ-502 MH8
25AEHPJ-505 MH6
25AFHPJ-505 MH5
25AGFN-756 MH3
25AGN-751 MH2
25AHJP-505 MH4
25AJ-501 MH7
25ATJ-503 MH9
25CAVGJ-514-00 MH16
Page NI2
Cardiac Surgery Catalog Reorder Number Index
Mechanical Heart Valves
Reorder Number Page Number
25MECJ-502 MH12
25METJ-504 MH14
25MHPJ-505 MH10
25MJ-501 MH11
25MTJ-503 MH13
25VAVGJ-515 MH15
27AECJ-502 MH8
27AEHPJ-505 MH6
27AFHPJ-505 MH5
27AGFN-756 MH3
27AGN-751 MH2
27AHJP-505 MH4
27AJ-501 MH7
27ATJ-503 MH9
27CAVGJ-514-00 MH16
27MECJ-502 MH12
27METJ-504 MH14
27MJ-501 MH11
27MHPJ-505 MH10
27MTJ-503 MH13
27VAVGJ-515 MH15
29AECJ-502 MH8
29AJ-501 MH7
29ATJ-503 MH9
29CAVGJ-514-00 MH16
29MECJ-502 MH12
29METJ-504 MH14
Reorder Number Page Number
29MJ-501 MH11
29MTJ-503 MH13
29VAVGJ-515 MH15
31AECJ-502 MH8
31AJ-501 MH7
31ATJ-503 MH9
31CAVGJ-514-00 MH16
31MECJ-502 MH12
31METJ-504 MH14
31MJ-501 MH11
31MTJ-503 MH13
33CAVGJ-514-00 MH16
33MECJ-502 MH12
33METJ-504 MH14
33MJ-501 MH11
33MTJ-503 MH13
35MJ-501 MH11
37MJ-501 MH11
905-HH MH17
905-HH MH18
905-MHH MH18
905-RHH MH18
AG-RHR MH17
AHP-RHR MH18
A-RHR MH18
LT100 MH17, 18
M-RHR MH18
Valve Repair
Reorder Number Page Number
AFR-25 VR2
AFR-27 VR2
AFR-29 VR2
AFR-31 VR2
AFR-33 VR2
AFR-35 VR2
AFR-37 VR2
AFR-39 VR2
AFR-41 VR2
AFR-43 VR2
C0205 VR7
C0405 VR7
C0510 VR7
C0914 VR7
EX-05 VR8, 9, 10
HH-05 VR8, 9, 10
RSAR-057A VR9
RSAR-24 VR5
Reorder Number Page Number
RSAR-26 VR5
RSAR-28 VR5
RSAR-30 VR5
RSAR-32 VR5
RSAR-34 VR5
SAR-501 VR10
SARP-24 VR6
SARP-26 VR6
SARP-28 VR6
SARP-30 VR6
SARP-32 VR6
SARP-34 VR6
SARP-36 VR6
SARP-38 VR6
SARP-40 VR6
TAB-25 VR4
TAB-27 VR4
Page NI3
Cardiac Surgery Catalog Reorder Number Index
Valve Repair
Reorder Number Page Number
TAB-29 VR4
TAB-31 VR4
TAB-33 VR4
TAB-35 VR4
TAR-505 VR8
TAR-510R VR11
Reorder Number Page Number
TARP-25 VR3
TARP-27 VR3
TARP-29 VR3
TARP-31 VR3
TARP-33 VR3
TARP-35 VR3
Cardiac Ablation
Reorder Number Page Number
ACS-US-2 CA2
CC-6-LP-CE CA5
IVS-UC CA8
LP-OBL-1 CA7
LP-PAS-1 CA6
UC-LP-7 CA3
UC-LP-8 CA3
UC-LP-9 CA3
UC-LP-10 CA3
UC-LP-11 CA3
UC-LP-12 CA3
UC-LP-13 CA3
UW-LP-2 CA4
Page TS1
Placing Orders
Orders received by St. Jude Medical (SJM) are
subject to acceptance at its St. Paul, Minnesota
facility and are deemed accepted only when
conrmed in writing or upon SJMs commencement
of performance.
Orders may be placed:
In Writing
St. Jude Medical
177 East Country Road B
St. Paul MN 55117
When placing an order in writing, the following
information should be provided:
Pricing, if known
Serial number
By Direct Dial Telephone
(800) 544-1664
When placing an order by telephone, you will
be asked to provide the following information:
Pricing, if known
A conrmation number will be faxed back to
the contact with any corrections noted.
Payment Terms = Net 30 Days
Shipping
FOB: Shipping Point
Transit Damage
Although SJM takes special care in packaging
its products, damage may occur in transit. All
products should, therefore, be inspected upon
receipt. Any damage should be noted on the freight
bill and reported to the carrier within ve (5) days
of shipment arrival. SJM cannot accept responsibility
for damage after shipments have been accepted by
the carriers agent.
Terms of Sale
Page TS2
Product Returns
Advance authorization and an assigned return goods
authorization number (RGA #) are required from
SJM prior to return of any product. An RGA # may
be obtained by contacting your sales representative.
If your sales rep is not known, you may call
Customer Service, who will be able to put you in
contact with the appropriate sales personnel.
The following information will be required to obtain
a return goods authorization number (RGA #):
Quantity to be returned
Serial number
Limited Warranty
St. Jude Medical, Inc. (SJM) warrants that reasonable
care has been used in the manufacturing of this
device. THIS WARRANTY IS IN LIEU OF AND
EXCLUDES ALL OTHER WARRANTIES NOT
EXPRESSLY SET FORTH HEREIN, WHETHER
EXPRESS OR IMPLIED BY OPERATION OF LAW OR
OTHERWISE INCLUDING, BUT NOT LIMITED TO,
ANY IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE, since
handling, storage, cleaning, and sterilization of this
device as well as factors relating to the patient,
diagnosis, treatment, surgical procedures, and other
matters beyond SJMs control directly affect this
device and the results obtained from its use. SJM
SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR
CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE
directly or indirectly arising from the use of this device
other than the replacement of all or part of it. SJM
neither assumes, nor authorizes any other person
to assume for it, any other or additional liability or
responsibility in connection with this device.
Some states in the United States do not allow
limitations on how long an implied warranty lasts,
so the above limitations may not apply to you. This
limited warranty gives you specic legal rights, and
you may have other rights which vary from jurisdiction
to jurisdiction.
Descriptions of the specications appearing in SJM
literature are meant solely to generally describe
the device at the time of manufacture and do not
constitute any express warranties.
Terms of Sale
Rx only
Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions,
potential adverse events and directions for use.
Unless otherwise noted
indicates a registered or unregistered trademark or service mark owned by, or licensed to, St. Jude Medical, Inc. or one
of its subsidiaries. Attune, Biocor, Epic, FlexFit, Regent, HP, SJM Rigid Saddle Ring, SJM Sguin Semi-Rigid Ring, Tailor, Linx, FlexCuff, Trifecta,
Epicor, UltraWand, UltraCinchSJM Pericardial Patch, ST. JUDE MEDICAL, the nine-squares symbol and MORE CONTROL. LESS RISK. are trademarks
and service marks of St. Jude Medical, Inc. and its related companies. Hemashield