200 t NEW:
% % Improved Combined Error: 0.07 % Improved TKC Error: 0.03 % / 10K

Further Features:
% % % % Six-wire circuit Service temperature up to 150C Integrated sensor for temperature monitoring Separate mounting of connecting cable through connector

Application % % % % Ladle turret scales Ladle ferries Scrap bucket, roller table weighing and tundish scales Silo and hopper scales

Function % Simple and economical installation through direct screwing to the connecting structure without movable parts No need for additional tierods and hold-downs Virtually impervious to shock loads and unavoidable side forces Suitable to the construction of service free scales in severe environments Minimal measurement value reaction on high interferential forces and moments % % % High long-term stability High degree of repeatability Separate mounting of weighbeam and connecting cable possible Easy cable exchange

% %

Construction % % Rugged design, low headroom From 50t: Locating head for formlocking absorption of side forces Connection of cable and weighbeam through a connector (also right-angle type)

BV-D2059GB

Operating principle DWB 40 t Load L Load L Side load Lq

Weighbeam Support

DWB 50 ... 200 t

Load L

Load L Side load Lq

Weighbeam

Support

Technical Data
DWB 40 t Rated capacity Limit load (with L q=0.15xL n) Limit load = Maximum admissible load Rupture load (with L q=0.15xL n) Max. admissible side load Sensitivity Combined error Creeping under load (30 min) Input resistance Output resistance Reference supply voltage Max. supply voltage Nominal temperature range Service temperature range Reference temperature Storage temperature range Temperature effect on zero signal Temperature effect on sensitivity Dead weight Corrosion protection Protection class Cable specification Emax LI Ld Lqmax Cn Fcomb Fcr Re Ra Usref Usmax Btn Btu Tr Bts TKo TKc me 39 kg 40 kg 40 t 100 t 160 t 40 t 0.95 mV/V + 0.1% DWB 50 t 50 t 120 t 200 t 50 t 1.08 mV/V DWB 100 t 100 t 210 t 350 t 85 t 1.38 mV/V DWB 150 t 150 t 290 t 480 t 120 t 1.57 mV/V DWB 200 t 200 t 360 t 600 t 150 t 1.63 mV/V Emax Cn Cn Tr Tr
Reference

+ 0.07% + 0.05% 756 + 6 700 + 4 10V 36V - 10C to + 100C - 15C to + 150C + 22C - 50C to + 180C + 0.05% / 10K + 0.03% / 10K 55 kg hot dip galvanized IP 65 85 kg 120 kg

Cn in Btu

Teflon (PTFE) 6 mm x 15 m, screened, including plug socket; Bending radius: > 40 mm, Temperature range: -50...+200C; Wire assignment: 6 wires for measurement value; 2 wires for temperature monitoring

Mounting Dimensions DWB 40 t


(Load application width)

DWB 50 ... 200 t

Variant DWB 50t DWB 100t DWB 150t DWB 200t

A B C D F G H I K L M mm mm mm mm mm mm mm mm mm mm mm 450 500 560 620 120 130 140 143 160 158 180 175 105 118 133 150 398 444 500 560 68 80 94 114 75 90 102 110 40 44 44 44 80 90 90 90 110 130 150 160 26 30 33 33

N M20x30 M24x36 M24x36 M24x40

O P R mm mm mm 32 38 38 40 45 54 66 75 340 370 410 450

S mm 25.5 28.5 32 32

T mm 57 62 69 76

Connecting surface quality requirements DWB 40 t upper connecting surface weighbeam lower connecting surface DWB 50...200 t upper connecting surface weighbeam lower connecting surface

% %

Variant DWB 40 t DWB 50 t DWB 100 t DWB 150 t DWB 200 t Spare Part: High temperature connecting cable 15 m with plug socket

Order No. D 726 615.01 D 726 615.02 D 726 615.03 D 726 615.04 D 726 615.05 D 726 614.01

Variant DWB 40 t PUR DWB 50 t PUR DWB 100 t PUR DWB 150 t PUR DWB 200 t PUR

(*)

Order No. D 726 615.06 D 726 615.07 D 726 615.08 D 726 615.09 D 726 615.10 D 736 003.01

Spare Part PUR: (*) connecting cable for outdoor use 15 m with plug socket

(*) Deviant technical data of the PUR variant: suitable for outdoor use (better protection class IP 66), max. service temperature 80 C, a temperature sensor is not included

81 Two Bridges Road Bldg. 2 Fairfield, NJ 07004 Phone: (800) 401-9702 Fax: (973) 882-3796 E-Mail: mktg@schenckamericas.com Web site: www.schenckamericas.com

BV-D2059GB 0325. We reserve the right to discontinue or change specifications or designs at any time without notice or obligation.

Material quality A: Usually construction steel of a minimum quality S355 is used Plate thickness B: Depends on stiffness of total construction. Plate thickness of connecting surface must be at least 40% of the weighbeam height Surface quality C: Requisite mean roughness of the connecting surfaces is 6.3 m

Planeness D: Maximum admissible planeness tolerance within every connecting surface is 0.05 mm Angular deviation error to vertical axis E: Angle deviation of connecting surface to vertical axis in both planes of view must not exceed 2

Plane parallelism F: Upper and lower connecting surfaces to the weighbeam have to be plane parallel to minimum 0.1 mm