NHDS UNIT PUMP ADEQUACY

Centrifugal Pumps Existing Mass flow as per Mass balance (kg/hr) Proposed Mass flow as per Mass balance (kg/hr) 3) Density (kg/m Poposed flowrate as per mass balance (m /hr) Pump capacity selected (m3/hr) Is pump capacity > required Flow Rate? Adequacy Reciprocating Pumps Mass flow as per Mass balance (kg/hr) 3) Density (kg/m 3 Required flowrate as per mass balance (m /hr) Pump capacity selected (m3/hr) Pump capacity selected (ml/hr) Is pump capacity > required Flow Rate? Adequacy
3

PU-201 A/B 25000 25000 756 33.069 37.5 Yes Adequate PU-205 3.364E-09 850 5.80E-05 0.000058 58.0 Yes Adequate

PU-202 A/B 39733 39537 552 71.625 82.9 Yes Adequate PU-206 7.42 1060 7.00E-03 0.007 7000 Yes Adequate

PU-203 A/B 4437 4660 553 8.427 9.6 Yes Adequate

NHDS UNIT PUMP ADEQUACY


PU-204 0 -0 3.300 4.6 Yes Adequate

REFORMING UNIT PUMP ADEQUACY Centrifugal Pumps Mass flow as per Mass balance (kg/hr) 3) Density (kg/m Required flowrate as per mass balance (m /hr) Pump capacity selected (m3/hr) Is pump capacity > required Flow Rate? Adequacy Reciprocating Pumps Mass flow as per Mass balance (kg/hr) 3) Density (kg/m 3 Required flowrate as per mass balance (m /hr) Pump capacity selected (m3/hr) Pump capacity selected (ml/hr) Is pump capacity > required Flow Rate? Adequacy
3

PU-301 A/B 13985 678 20.627 37.5 Yes Adequate PU-305 0.114144 1160 9.84E-05 9.84E-05 98.4 Yes Adequate

PU-302 A/B 12558 783 16.038 82.9 Yes Adequate PU-306 0.0201 1000 2.01E-05 1.51E-04 151 Yes Adequate

PU-303 A/B 2935 503 5.835 9.6 Yes Adequate PU-307 15.892 1160 1.37E-02 2.50E-02 25000 Yes Adequate

PU-304 A/B 18408 568 32.408 39.7 Yes Adequate

REFORMING UNIT COMPRESSOR ADEQUACY

Centrifugal Compressor Mass flow as per Mass balance (kg/hr) Density (kg/m at compressed T,P condition Operating Temperature (c) Operating Presssure (kg/cm2G) Required flowrate as per mass balance (m /hr) Required flowrate as per mass balance (Nm /hr) Compressor capacity selected (Nm3/hr) Is compressor capacity > required Flow Rate? Adequacy
3 3 3)

CO-301 7520 5.2 75 22.5 1446.154 25528.883 27760 Yes Adequate

CO-302 A/B 1427 6.7 94 31.2 212.985 4943.806 5268 Yes Adequate

SPI UNIT PUMP ADEQUACY Centrifugal Pumps Mass flow as per Mass balance (kg/hr) Density (kg/m3) Required flowrate as per mass balance (m /hr) Pump capacity selected (m3/hr) Is pump capacity > required Flow Rate? Adequacy Reciprocating Pumps Mass flow as per Mass balance (kg/hr) Density (kg/m3) Required flowrate as per mass balance (m3/hr) Pump capacity selected (m3/hr) Pump capacity selected (ml/hr) Is pump capacity > required Flow Rate? Adequacy
3

PU-401 A/B 16488 830 19.865 22.3 Yes Adequate PU-404 598.8 998 0.6 0.91 910000 Yes Adequate

PU-402 A/B 52672 824 63.922 140 Yes Adequate PU-405 0.40174 1060 3.79E-04 3.78E-03 3785 Yes Adequate

PU-403 A/B 2794 673 4.152 5.5 Yes Adequate PU-406 A/B 22.68 1200 1.89E-02 0.189 189000 Yes Adequate

PU-408 A/B 18285 1150 15.900 15.9 Yes Adequate PU-407 0.01275 850 1.50E-05 1.50E-04 150 Yes Adequate

PU-410 5750 1150 5.000 5 Yes Adequate PU-409 229.54 998 0.23 0.23 2.30E+05 Yes Adequate

PU-411 18000 900 20.000 20 Yes Adequate

SPI UNIT COMPRESSOR ADEQUACY CO-401 A 255 6.02 105 42 42.359 1285.080 1417 Yes Adequate CO-402 B 255 11.7 106 84.4 21.795 1325.217 1417 Yes Adequate CO-401 RECYCLE 2609 10.9 78 84 239.358 15639.951 16461 Yes Adequate

Mass flow as per Mass balance (kg/hr) Density (kg/m3) at compressed T,P condition Operating Temperature (c) Operating Presssure (kg/cm2G) Required flowrate as per mass balance (m3/hr) Required flowrate as per mass balance (Nm3/hr) Compressor capacity selected (Nm3/hr) Is compressor capacity > required Flow Rate? Adequacy

CO-301 Mass flow as per Mass balance (kg/hr) Density (kg/m3) at compressed T,P condition Operating Temperature (c) Operating Presssure (kg/cm2G) Required flowrate as per mass balance (m3/hr) Required flowrate as per mass balance (Nm3/hr) Compressor capacity selected (Nm3/hr) Is compressor capacity > required Flow Rate? Adequacy 7520 5.2 75 22.5 1446.154 25528.883 27760 Yes Adequate

CO-302 1427 6.7 94 31.2 212.985 4943.806 5268 Yes Adequate

CO-401 A Mass flow as per Mass balance (kg/hr) Density (kg/m3) at compressed T,P condition Operating Temperature (c) Operating Presssure (kg/cm2G) Required flowrate as per mass balance (m3/hr) Required flowrate as per mass balance (Nm3/hr) Compressor capacity selected (Nm3/hr) Is compressor capacity > required Flow Rate? Adequacy 255 6.02 105 42 42.359 1285.080 1417 Yes Adequate

CO-402 B 255 11.7 106 84.4 21.795 1325.217 1417 Yes Adequate

CO-401 RECYCLE 2609 10.9 78 84 239.358 15639.951 16461 Yes Adequate

PROJECT : RENOVATION OF PETRROCHEMICAL COMPLEX

ADEQUACY STUDY REPORT

Customer: MYANMA PETROCHEMICAL ENTERPRISE

Location: MYANMAR

0 Rev.

17-Sep-13 Date Description Prep. By Chk. By App. By

Process System Engineers (I) Pvt. Ltd.


Doc no:- 5002-PR-SR-00-201 Rev. No. : 0

Page 7 of 8

Location: MYANMAR

App. By

ocess System Engineers (I) Pvt. Ltd.


Page 8 of 8

Anda mungkin juga menyukai