UNIT:
PU & DP
DOCUMENT NO.: MIS-M-DS-04044 Company Project Number: Purchase Order Number: Supplier Project Number:
REV. A
PAGE 1 OF 2
Purchaser Purchase
Vender As Built
DESIGN CRITERIA Service: Design Code: Vessel Size: Thickness: Vessel Type: Heads: Medium: ID. Shell: Vertical 2:1 Ellipse Hydrocarbon Severe Location: Indoor Under Shelter PROCESS DATA Open Drain Drum ASME Section VIII - Division 1 2400 mm mm S/S Head: Horizontal Other Type: Lethal Wet H 2S Outdoor Under Ground Cyclic 6600 mm mm Material Code: Shell: Head: Pipes: Flange: Blots: Nuts: Gaskets: Supports: Internals:
MATERIALS ASME Section II A516-60 A516-60 A106 Gr.B A105 A193 A194-2H Spirally Wound Non-asbestos Gaskets A36 A516-60
MANUFACTURE AND TEST REQUIREMENTS Manufacturing Code: MPag Welding Code: NDE Code: Ultrasonic: Magnetic Paricle: X-Ray Inspection Length: X-Ray NDE Grade: Hydraulic Test: Painting and Packing: ASME Section VIII-Division 1 ASME Section IX ASME Section V As Per Code As Per Code As Per Code As Per Code Yes Yes No No
kg/m3 No No MPag
o o o
Board Registration: Internal Design Pressure: Top, Mpa Bottom, Mpa Design Temp: Normal Liquid Level: Max Wind Speed: Seismic Zone: Corrosion Allowance: Shell: Insulation: Type: 3 mm
C C C
mm m/s
INTERNALS Yes No
A Rev.
Fan Xixuan By
Lu Huanxuan Reviewed