Anda di halaman 1dari 8

FEATURilN@

SYLVANIA'S NEW HIGH INTENSITY TYPTS AN D EXCLUSIVE VERY NARROW BEAM SPOTLIGI.ITS T__l

SYLl/ANIA'S
CONTROLLED.BEAM

PAR
REFLECTOR LAMPS
PUT LIGHT PRECISELY WHERE Y{IU WANT IT

New Higher Wattage Spots and Floods Plus Exclusive Very Narrow Spots. . ro the popurar rine or pAR 38 spots and floods in the lower wattages, Sylvania has added new high intensity types in sizes up to 500 watts . . . plus the new and ex-

clusive Very Narrow Beam PAR lamps, never before available for difficult vertical spotlighting. All these types are described in detail on the next two pages. You can use them for . . .
OUTDOOR SPOT AND FLOODLIGHTING

. Churches . Steeples and Towers . lndustrial Plants . Park and Landscape Lighting. Shipyards . Lumber Yards. Railroad Classification Yards . Protective Lighting . Safety Lighting
Public Buildings
COMMERCIAL AND DISPLAY LIGHTING

tions

Signs

Display Windows . Parking Lots . Filling Sta-^ Amusement Parks . Sports Areas . SOeciaJ Event and Christmas Lighting

Billboards

Road Stands

HOME OUTDOOR LIGHTING Patios . Yards . Gardens . Garages . Driveways . Private Roads . Swimming Pools . Tennis Courts . Party and Christmas Lighting

Controlled Light

Direction

'

Sylvania PAR Reflector Lamps have a hermetically sealed-in aluminum reflecting surface with the filament scientifically positioned - in spot or floodlighting patterns. Result, to direct light accurately no light is wasted because all light is channelled - exactly where you want it,

More Light for Your Money


Sylvania PAR lamps use no more electricity than ordinary incandescent lamps of the same wattage. But they give you more light for your money by increasing the useful light in the areas where you need it.

Lower Maintenance Costs


Rated life of most Sylvania PAR lamps is 2000 hours-more than double that of ordinary incandescent bulbs of the same wattage. This means much longer service-with your high labor costs for lamp replacement cut in half. What's more, the PAR lamp's sealed-in reflector can't be dimmedr by dust, dirt or grime. So light output stays high for the life of tht lamp and it never needs cleaning. Another maintenance-savingfeature that cuts your labor costs especially where larnps are mounted high or hard to reach.

lt

SPOTS AND
FLOODS
AND HOW TO USE 'EM
PAR SPOTLIGHTS are designed to throw an intense narrow beam to concenareas

\,,,,1

Rugged PAR Construction To withstand thermal shock and provide greater strength, all Sylvania PAR lamps are made of heat resistant "hard" glass. A few types, such as the medium skirted PAR 38
types, have screw bases. Most higher wattage types have side prongs or end prongs for electrical contact. These bases allow for precise control of elliptical light distribution pattern of the PAR 46, PAR 56 and PAR 64 types. Screw terminal bases are also used in low voltage high current types. TIPAR" stands for the "Parabolic Aluminized Rediameter measured in eighths of an inch. For exam. ple, the PAR 38 bulb is 47+ inches in diameter.

- small trate light on

To dramatize larger areas they are used in closely


spaced lines or groups. They are not recommended for general lighting.
PAR FLO0DLIGHTS are designed to distribute a broader,

usually some distance away.

flector" built into every Sylvania PAR lamp. The number following the lamp type gives the bulb

more uniform beam. They're used for short-distance broad area floodlighting and general outdoor lighting.
SPOTS AND FLOODS

IN

COMBINATION

Versatile PAR Fixtures Mounting equipment for PAR lamps are

available

from many manufacturers. Most are designed with provision for directional control. Various types of PAR 38 holders have self-contained mountings . . . can be clamped on stands or poles. . set on the ground or spiked into it. . . or connected to conduit or to junction boxes. Other types can be mounted on,
or recessed in walls and ceilings.

Spotlights and floodlights can be effectively used in combination where both general lighting and accent lighting are desired. When this is done, spotlights should be focused on the more distant sections and floodlights on the nearer sections of the area to be lighted.
UNIOUE ORIENTATION FEATURE
On the face of all large Sylvania

Outdoor fixtures for higher wattage PAR lamps usually have glass covers to prevent contact with moisture. Correct fixture design allows adequate cooling so safe operating temperatures for lamp parts, sockets and wiring, will not be exceeded. A variety of types is illustrated.

PAR lamps in 200 to 500 watt sizes, you'll find a small oval "directional guide". This indicates the wide axis of the beam on both spots and floods helps in placing the lamp and aiming its light accurately prior to "light-up".

ffi

ffi o$o

SYLVANIA PAR REFLEGTORT


PCIPULAR PAR

38

SPOTS ANII Fl{ltltls


PAR 38

The PAR 38 is designed primarily for outdoor use but can also be used indoors. Special feature is its extra rugged filament hook support to protect the filament against vibration and shock and provide longer service life. Of hard glass construction, exposed PAR 38's can be used outdoors but porcelain sockets must be used.

MEDIUM SKIRTED

PAR 38 . . . 75 AND 150 WATT. . . MEDIUM SKIRTEI! BASE Spotlights ln 75 watt size for low level requirements. ln 150 watt size for short-to-medium distance spotlighting - or for higher intensities at close range. Floodlights ln 75 watt size for low-intensity small area floodlighting. ln 150 watts for larger areas or for higher intensities on small areas.

PAR 38

SIDE PRONG

lr

38 I

PAR 38 . . .150 WATTS . . . SIDT PR(ING BASE Spot and Flood ln 150 watts only-for use where fixture compactness is important. PAR 38 FL(I(}DS IN 7 COL(IRS. . .1OO WATT Floodlight type only, in yellow, green, red, blue, blue-white, pink and amber. For dramatic effects with color. Same general uses as regular PAR 38's. Medium skirted base. PAR 56 SWIMMING P(l(lL LIGHT A special 12-volt lamp for underwater lighting- it's far safer to use in such applications than 120 volt types. Must be used with matching 12 volt transformer. Meets codes for low voltage underwater lighting. Wide flood beam spread only, 300 watts, 1000 hour rated life, screw terminal base.

PAR 56 FLOOD SWIMMING POOL

SYLt|A].lIA'S

EXCLUSIIJE
IIERY ].|ARROW
SP0TS
FoR H,GH
INTENSITY VERTICAL LIGHTING OF STEEPLES, TOWERS, BUILDINGS

PAR 64 . . .120 WATT , . . SCREW TERMIT{AL BASE Extremely narrow beam (4V2" x 7") provides sharp cutoff by masking critical reflector areas and using a shield to prevent light scatter. Special coiled coil filament gives maximum candlepower of 2IO,O00. Rated life of 2000 hours is double that of conventional 72O watt, 6 volt lamps with rating of only 1000 hours.
PAR 64...500 WATT...EXTEI{DEII M()GUL ENII PR0NG BASE Similar construction but eliminates light shield for wider beam distribution of B" x 20". Maximum beam candlepower of 200,000 is approximately 4O/s above that of standard 500 watt PAR 64 Narrow Spots. Operates on any standard 120 volt circuit with no auxiliary equipment.

I
I

i
I :

TYPHS AIVD SnZHS rN 24 $0ME


SYLVANIA'S I{EW HIGFIER WATTAGE PAR SPI}TS
ANN
FLOCINS wattages will meet most needs for controlled beam lighting of higher intensities than the PAR 3B can supply. Though ruggedly constructed of hard glass these lamps are larger, heavier, and develop higher temperatures in burning than PAR 3B's.

These three new groups of Sylvania lamps of progressively higher

40 sPoT

They require glass covered, gasketed fixtures to shield them from - 130 volts. contact with moisture. Available in 120, I25 and
1i

PAR 46... 2OO WATT".. SIDE PR(}NG BASE Narrow Spot-17'x23" beam spread for medium range spotlighting. Medium Flood-20o x 40o beam spread for higher level indoor or outdoor f lood lighti ng. PAR 56 ...300 WATT... MOGUL ENI) PR(ING BASE Narrow Spot 15'x 20' beam spread for medium-to-long range spot- intensity lighting or high spotlighting at closer range. Medium Flood -20' x 35" beam spread for medium high intensity f loodlighting. AA/ide Flood- lncreases beam spread to 30" x 60", for lower light ltensity over a broader area. PAR $4 . . . 5OO WATT. . . EXTENI]EII M(}GUL END PROI{G BASE Narrow Spot 13" x 20" beam spread for long range spotlighting, or high intensity -spotlighting at closer range. Medium Flood 35" beam spread for medium high intensity -20'x floodlighting of large areas. Wide Flood- lncreases beam spread to 35" x 65'for lower light intensity over larger areas.
FOR SPECIFICATIONS

P.AR'5F{O.OD,.

PAR',8d

FtooD'

& ORDERING INFORIV]ATION ON ALLSYLVANIA PAR

LAI\1PS SEE BAOK OOVER

il
ilr

I)RAMATIC NEW BUI'IKER FlILL MONUMEI{T LIGI{TING Photos show dramatic improvement gained by using

FACADE LIGFITING FOR

NEW

GEORGIA

PCIWER BUILIIING
This superb effect in vertical lighting (also shown on cover of this booklet) is a dramatic

watt PAR 64 Yery Narrow Spots. Twelve lamps are mounted in a vertical row on two 25-foot poles 250 feet
away from monument base.

Sylvania's exclusive new 500

contrast of light with shadow . achieved by using Sylvania's Very Narrow Spots. The 300 foot high facade has

lights two sides of the monument. By superimposing the very narrow 8" x 20' elliptical beam spread of each lamp, one above the other, the full
221 f oot height of the monument is now visible for miles.
Previous Lighting New Sylvania Lighting

at opposite corners, each pole of la m ps


Positioned

nine columns

aimed at the top to wash down to the 150 foot level while three 500 watt PAR 64's with 8o x 2Oo beam
concrete 14 feet from base.

Nine 120 watt PAR 64's with beam spread of 4\ x 7o were

6 feet

wide.

spread took care of the lower level. Lamps are recessed in

SYLVANIA PAR LAMP LIGHT o DISTRIBI..JTION CURVES


u000

10000

9000

80m

/000

15000

6000

10,000

5000

4000

3000

2OO
2000

WATT PAR 46 NARROW FLOOD


3OO

1000

WATT PAR 56 NARROW SPOT

2A.

30'

40'

PAR 38 SPOTS

2OO
6000

WATT PAR 46 MEDIUM FLOOD

5000

= 3 a

3000

2000

1000

3OO

WATT PAR 56 MEDIUM FLOOD

15,000

12500

n'

30'

40'

PAR 38 FTOODS

E
5

ro ooo

7,500

5,000

2,500

OEGf,tES

3OO

WATT PAR WIDE FLOOD

56

CURVES F0R PAR 38 LAMPS show circular area lighted by the beam.

the tight distribution for hatf the

FO$TG&ruru17

P&TTgRN$

CIJH'.['.1"'*iJ:'f"T:i,:1illiffi
long axis of the "directional

guide" on the lamp lens, Dotted line shows vertical distribution in plane perpendicular to the long axis of the "directional guide. "

,ru:,iri,l];.?ooyi:?,"i.;iH

The controlled directional beam of the PAR lamp is cone-like in shape. Each type of PAR lamp has a distinct illumination pattern which var. ies in size and light intensity-depending on the angle at which the lamp is aimed and on its distance from the area illuminated.

4
I

MOUNTING HEIGHT

5'
3',

30
20

FC FC
5',

5 Ft.

Dr0Rtts

I2O WATT PAR

64

VERY NARRO\^i SPOT


10505101524

0Etrts

5OO

WATT PAR

64

NARROW SPOT

(D

When centered directly on the surface to be lighted (at right angles or zero degrees) the small PAR 38 sizes give a round lighting pattern. The concentric rings show the amount of light measured in footcandles at various distances from the beam center. The round lighting pattern changes to oval or elliptical when the lamp is aimed at an angle. +s" ,,."1 o',1"\ to"

----7i'-

ID",

,/

3OO WATT PAR

@@
SPOT

56 NARROW

424?46
OEGNE6

5OO

WATT PAR

64

VERY NARROW SPOT

@@
!4EDIUM FLOOD

5OO

WATT PAR 64 MEDIUM FLOOD

The lighting pattern of the larger mately oval or elliptical, whether centered directly on the surface or aimed at an angle. As shown in the
PAR 46, 56, and

64lamps is approxi-

OEORIES

5OO

WATT PAR 64 WIDE FTOOD

two diagrams, aiming PAR lamps at progressively greater angles - proportionately increases both the length and width of the area illuminated. ln general, for spotlights the length of the lighting pattern becomes proportionately greater-a nd in the case of floodlights, the width.
For planning PAR lamp installations, additional data for alN Sylvania PAR lamps. .. are available on rcquest at your nearest Sylvania Sales 0ffice.

SYTWANIA PAR
RHFI-HGTOR LAfuI PS
SPECIFICATIONS AND ORDERING INFORMATION
FOR FURTF|IR DITAILS OALL YOUR NTARTST SYLVANIA DISTRICT SALIS OFFICE

APPROX.

BEAM WATTS
BU

STD.

LB

BASE l\4ed. Skirt

VO

LTS

ORDERING ABBRTVIATION 75 PAR/SP 75 PAR/'FL

0ESCRlPTl0l,l
Spot (KM) Flood (KM)

SPREAO (Degrees) (R)

PKG,
QTY.

RATED HOURS

LIFE
2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
1000

M.0.1.
5/ra

l5

PAR 38

120, 125, 130

I2
12

5lr
5r;
srit
5"/tt
5y'ra
5y'tc,

100

PAR 38

I\4ed. Skirt

15-125

100 PART'Y 100 PAR/G 100 PAR/R 100 PAR/B 100 PAR/BW 100 PAR/PK 100 PAR,iA

Yellow (M)
Green (M)
Red

I2
T2

(M)

I2
12 12
12

Blue (M) Blue-White (M) Pink (M) Amber (lVl)


Spot (KM) Flood (KM) Compact Spot (PM) Compact Flood (PM) Narrow Spot Med. Flood Wide Flood* (Swimming Pool) Narrow Spot Med. Flood Wide Flood

5,/tt,
5,/r,;,

12 12

150

PAR 38

Med. Skirt

std,130

150 PAR/SP
150 PAR//FL

5'/n

I2 t2

Med. Side Prong

r20, r25

150 PAR//3SP 150 PAR/'3FL

'^n)
4,/tr,
4 4

l2 17' x 23"
I2

200 200 300 300 300


300

PAR 46 PAR 46 PAR 56 PAR 56 PAR 56 PAR 56 PAR 64 PAR 64 PAR 64 PAR 64 PAR 64

IMed. Side Prong I\4ed. Side Prong

120,125,130 120,125,130
12

200 PAR46/3NSP 200 PAR46i3ivtFL

20' x 40'

I2
12

Screw Terminal
lVlog. End Prong

25Ai PAR56/WFL
300 PAR56/NSP 300 PAR56,,'MFL 300 PAR56/'WFL 120 PAR64/VNSP s00 PAR64/VNSP 500 PAR64/NSP 500 PAR64/rvrFL
5OO

4%
5

120,125,130 120,125,130
120, 125, 130
6

15" x 20"

12 12
12 6

2000 2000 2000 2000 2000 2000 2000 2000

Mog. End Prong


lVlog. End Prong

20' x 35' 30' x 60'

5 5

r2a
500

Screw Terminal Ext. Mog. End Prong Ext. Mog. End Prong Ext. Mog. End Prong Ext. I\409. End Prong

Very Narrow Spot Very Narrow Spot


Narrow Spot Med. Flood Wide Flood

4l'x7'
8" x 20"
13" x 20"

120

6 6 6
6

5.31
6 6 6

500
500 500

120,125
120, 125, 130 120, 125,130

20' x 35' 35' x 65'

PAR64,'WFL

(K)

Sh0uld be buroed only in Borcelain socketsuse.

(M) Suitable for both 0utdoor and ind0or

*
(P) (R)

45o base down to horizontal For use only with heat-rsisting connector and with lamp supported by balb

rin or

metal sbell of base.

To l09i 0f maximum candlepower.

SYL\?\hfA
OEI{EBA

/ TET EPHO4YE

{GCirrar)

&

EI ECTB O /Y/ C8

\t':rg./

-.ri

60
Printed ln U. S.A.

BOSTON STREET SALEM, MASSACHUSETTS


1.203.6/62.AN.DR