Anda di halaman 1dari 3

Demister sizing using normal flow conversion:

Customer: Enquiry No: Item No: Date:

7-Feb-14

Flow Data Normal Flow @ STP (Q1) Actual Temp (T2) Actual Pressure (P2) Allow Press drop (DP) Density gas (p g) Density liq (p l) Normal Temp. (T1) Normal Pressure (P1) Actual Flow (Q2) = 273.15 101.325 #DIV/0! #DIV/0!

UNITS Nm3/hr C kPa (a) mm H2O kg/m3 kg/m3 Kelvin kPa Am3/hr Am3/s N.B. If given system P2 is gauge, add to Patm. (Patm = 101.325 kPa at sea-level)

Actual Flow (Q2) = (Q1 x P1 x (T1 +T2))/(T1 x P2)

DEMISTER SIZING Vmax = 0.105 x SQRT((p l - p g)/p g) Vmax = Vopt = Free Area (Aopt) = Required Open Dia. (D) = DEMISTER (50mm supp) = ACTUAL DEMISTER = Free Area (Aact) = Vact = % of Vmax = EFFICIENCY GUARANTEE: #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! m/s m/s m mm
2

Vopt = 0.75 x Vmax Aopt = Q2 (m3/s) / Vopt Demister = = Pi x D2 / 4

D + (2 x support ring width) Typically D + 100mm

mm mm m2 m/s

0.008 #DIV/0! #DIV/0!

Typically D - 100mm

REMOVAL OF DROPLETS > 5 Micron. (AT DESIGN FLOW CONDITIONS) SUBJECT TO UNIMPEDED FLOW ACROSS DEMISTER SURFACE AREA, & FREE OF SOLID PARTICULATE. WIRE = 0.265mm KNIT IN 1 x 150mm LAYERS. 3 mm H2O AT KNIT DENSITY OF 168 kg/m

MESH PAD MATERIAL: PRESSURE LOSS:

If gas density given is at Normal conditions: Normal Density (p 1) = Actual Density (p g) = 0.000

kg/Nm3 kg/m3 Actual Density (pg ) = (p 1 x T1 x P2)/(P1 x (T1+T2))

Unit conversion key: 1/ Atmospheric Pressure at Sealevel: 2/ Temperature: 3/ Volume Flow Rate:

1 atm. = 760mmHg = 1013.25 mbar = 101.325 kPa. = 10332 mmH20 = 14.7 PSI 0 C = 273.15 K = 32 F 1 m3/s = 3600 m3/hr. = 2118.88 cfm

Note: If operating pressure (P2) is given as gauge, add to site atmospheric pressure, which will be less than sealevel pressure if site is at altitude. A negative operating gauge pressure indicates a suction system, resulting in actual operating pressure < atmospheric.

Prepared by M. SHUTTLEWORTH 2/7/2014

Page 1 of 3

Demister sizing using mass flow conversion:

Customer: Enquiry No: Item No: Date:

7-Feb-14

Flow Data Mass Flow @ Op. (M1) Actual Temp (T2) Actual Pressure (P2) Allow Press drop (DP) Density gas (p g) Density liq (p l) Normal Temp. (T1) Normal Pressure (P1) Actual Flow (Q2) = 273.15 101.325 #DIV/0! #DIV/0!

UNITS kg/hr C kPa (a) mm H2O kg/m 3 kg/m 3 Kelvin kPa m3/hr m3/s N.B. If given system P2 is gauge, add to Patm. (Patm = 101.325 kPa at sea-level)

Actual Flow (Q2) = (M1/p g)

DEMISTER SIZING Vmax = 0.105 x SQRT((p l - p g)/p g) Vmax = Vopt = Free Area (Aopt) = Required Open Dia. (D) = DEMISTER (50mm supp) = ACTUAL DEMISTER = Free Area (Aact) = Vact = % of Vmax = EFFICIENCY GUARANTEE: #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! m/s m/s m mm
2

Vopt = 0.75 x Vmax Aopt = Q2 (m 3/s) / Vopt Demister = = Pi x D2 / 4

D + (2 x support ring width) Typically D + 100mm

mm mm m2 m/s

0.008 #DIV/0! #DIV/0!

Typically D - 100mm

REMOVAL OF DROPLETS > 5 Micron. (AT DESIGN FLOW CONDITIONS) SUBJECT TO UNIMPEDED FLOW ACROSS DEMISTER SURFACE AREA, & FREE OF SOLID PARTICULATE. WIRE = 0.265mm SINGLE PLY. 3 mm H2O FOR 150mm THICK PAD AT KNIT DENSITY OF 168 kg/m .

MESH PAD MATERIAL: PRESSURE LOSS:

If gas density given is at Normal conditions: Normal Density (p 1) = Actual Density (p g) = 0.000

kg/Nm 3 kg/m 3 Actual Density (pg ) = (p 1 x T1 x P2)/(P1 x (T1+T2))

Unit conversion key: 1/ Atmospheric Pressure at Sealevel: 2/ Temperature: 3/ Volume Flow Rate:

1 atm. = 760mmHg = 1013.25 mbar = 101.325 kPa. = 10332 mmH 20 = 14.7 PSI 0 C = 273.15 K = 32 F 1 m 3/s = 3600 m3/hr. = 2118.88 cfm

Note: If operating pressure (P2) is given as gauge, add to site atmospheric pressure, which will be less than sealevel pressure if site is at altitude. A negative operating gauge pressure indicates a suction system, resulting in actual operating pressure < atmospheric.

Prepared by M. SHUTTLEWORTH 2/7/2014

Page 2

Demister sizing using actual flow conversion:

Customer: Enquiry No: Item No: Date:

7-Feb-14

Flow Data Actual Flow @ Op. (Q2) Actual Temp (T2) Actual Pressure (P2) Allow Press drop (DP) Density gas (p g) Density liq (p l) Normal Temp. (T1) Normal Pressure (P1) Normal Flow (Q1) = 273.15 101.325 0.000 0.000

UNITS Am3/hr C kPa (a) mm H2O kg/m kg/m3 Kelvin kPa Nm3/hr Nm3/s
3

N.B. If given system P2 is gauge, add to Patm. (Patm = 101.325 kPa at sea-level)

Normal Flow (Q1) = (Q2 x P2 x T1)/((T1+T2) x P1)

DEMISTER SIZING Vmax = 0.105 x SQRT((p l - p g)/p g) Vmax = Vopt = Free Area (Aopt) = Required Open Dia. (D) = DEMISTER (50mm supp) = ACTUAL DEMISTER = Free Area (Aact) = Vact = % of Vmax = EFFICIENCY GUARANTEE: #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! m/s m/s m mm
2

Vopt = 0.75 x Vmax Aopt = Q2 (m3/s) / Vopt Demister = = Pi x D2 / 4

D + (2 x support ring width) Typically D + 100mm

mm mm m2 m/s

0.008 0.000 #DIV/0!

Typically D - 100mm

REMOVAL OF DROPLETS > 5 Micron. (AT DESIGN FLOW CONDITIONS) SUBJECT TO UNIMPEDED FLOW ACROSS DEMISTER SURFACE AREA, & FREE OF SOLID PARTICULATE. WIRE = 0.265mm SINGLE PLY. 3 mm H2O FOR 150mm THICK PAD AT KNIT DENSITY OF 168 kg/m .

MESH PAD MATERIAL: PRESSURE LOSS:

If gas density given is at Normal conditions: Normal Density (p 1) = Actual Density (p g) = 0.000

kg/Nm3 kg/m3 Actual Density (pg ) = (p 1 x T1 x P2)/(P1 x (T1+T2))

Unit conversion key: 1/ Atmospheric Pressure at Sealevel: 2/ Temperature: 3/ Volume Flow Rate:

1 atm. = 760mmHg = 1013.25 mbar = 101.325 kPa. = 10332 mmH20 = 1.033 kg/cm2 0 C = 273.15 K = 32 F 1 m3/s = 3600 m3/hr. = 2118.88 cfm

Note: If operating pressure (P2) is given as gauge, add to site atmospheric pressure, which will be less than sealevel pressure if site is at altitude. A negative operating gauge pressure indicates a suction system, resulting in actual operating pressure < atmospheric.

Prepared by M. SHUTTLEWORTH 2/7/2014