Anda di halaman 1dari 33

Eqp. ID Eqp. Name Eqp.

Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1974 800.1 6.3 N Y 8.700

17C1 BOTTOM Column Sour Water Stripper COLUMNBTM RU IV

Asset ID

Carbon Steel \ SA-516 \ Grade: 55 None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 3473.7(Calc) 0.9 0.030(Mea) 123.7

Hydrogen Sulfide (0%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 0.3

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 0 0 0 0

Category
1 1 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.3 1 1 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

3,262,458

0.5

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

2. MEDIUM 499

1.530E-04

0.5

1 1.530E-04

0.5

1 1.530E-04

2. MEDIUM 499

2. MEDIUM 499

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC

Nom. Rem. Life [yrs]

209

Prob. Rem. Life [yrs]

211

Current Inspection(s)

None

11-Usually 1-Fairly

Inspection Plans
Thinning External Damage HTHA

txtSCCCurrentInspections

External Damage HTHA

None None

Target Driver None None None None None

Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 1 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1974 800.1 6.3 N Y 8.700

17C1 TOP Column Sour Water Stripper COLUMNTOP RU IV

Asset ID

Carbon Steel \ SA-516 \ Grade: 55 None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Gas) 0.9

Hydrogen Sulfide (1%) 3473.7(Calc) 0.050(Mea) 124.8

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.1

Future Status Before Inspection Factor 18-Oct-16


0.0 2.2

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 0 0 0 0

Category
1 2 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 2.3 1 2 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

3,262,458

0.5

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

2. MEDIUM 499

1.530E-04

2.2

2 6.732E-04

2.3

2 7.038E-04

2. MEDIUM 2,196

2. MEDIUM 2,296

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC

Nom. Rem. Life [yrs]

124

Prob. Rem. Life [yrs]

127

Current Inspection(s)

None

11-Usually 1-Fairly

Inspection Plans
Thinning External Damage HTHA

txtSCCCurrentInspections

External Damage HTHA

None None

Target Driver None None None None None

Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 2 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 489.0 5.9 Y Y 9.500

17E1A SHELL Feed/Effluent Exchanger EXCHANGER RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: E/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 95244.4(Calc) 4.5 0.048(Mea) 123.7

Hydrogen Sulfide (0%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 0 0 0 0

Category
1 1 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.0 1 1 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

1,029,643

0.5

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

2. MEDIUM

7.800E-05

0.5

1 7.800E-05

0.5

1 7.800E-05

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S

80
64

2. MEDIUM

80

2. MEDIUM

80

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

66

Current Inspection(s)

None

12-Usually 2-Fairly

Inspection Plans
Thinning External Damage HTHA

txtSCCCurrentInspections

External Damage HTHA

None None

Target Driver None None None None None

Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 3 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 21.2 Y 566.6 2.100 N

17E1A TUBE Feed/Effluent Exchanger EXCHANGER-TS RU IV

Asset ID

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Nickel \ 42Ni - 21.5Cr - 3Mo - 2.3Cu (UNS: N08825) \ SB-163 Class: Annealed None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 3473.7(Calc) 6.8 0.000(Exp) 93.3

Hydrogen Sulfide (0%)

Current Status 25-Dec-11


0.0

Future Status Before Inspection Factor 18-Oct-16


0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 0 0 0 0 0

Category
1 0 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 1 0 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

2,131,993

0.5

Risk (Total Cost) [USD/Yr] Thinning

2. MEDIUM 166

7.800E-05

0.5

1 7.800E-05

0.5

1 7.800E-05

2. MEDIUM 166

2. MEDIUM 166

Potential Damage Mechanism(s)


SCC External Damage HTHA Liner Thinning SCC Liner SCC
Generalized None

Nom. Rem. Life [yrs]

46724 Prob. Rem. Life [yrs] 7

4669 43

Current Inspection(s)

None None

12-Fairly

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 4 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 489.0 5.9 Y Y 9.500

17E1B SHELL Feed/Effluent Exchanger EXCHANGER RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: E/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 95244.4(Calc) 4.5 0.031(Mea) 101.3

Hydrogen Sulfide (0%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 0.0 0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 1 0 0 0

Category
1 1 1 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.0 0.0 1 1 1 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

1,029,653

0.5

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

2. MEDIUM

7.800E-05

0.5

1 7.800E-05

0.5

1 7.800E-05

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S Extl. Corrosion

80
99

2. MEDIUM

80

2. MEDIUM

80

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

102

Current Inspection(s)

None None

8-Usually 1-Fairly

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

7-Highly 2-Poorly None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 5 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 21.2 Y 566.6 2.100 N

17E1B TUBE Feed/Effluent Exchanger EXCHANGER-TS RU IV

Asset ID

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Nickel \ 42Ni - 21.5Cr - 3Mo - 2.3Cu (UNS: N08825) \ SB-163 Class: Annealed None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 3473.7(Calc) 6.8 0.000(Exp) 59.4

Hydrogen Sulfide (0%)

Current Status 25-Dec-11


0.0

Future Status Before Inspection Factor 18-Oct-16


0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 0 0 0 0 0

Category
1 0 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 1 0 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

2,131,993

0.5

Risk (Total Cost) [USD/Yr] Thinning

2. MEDIUM 166

7.800E-05

0.5

1 7.800E-05

0.5

1 7.800E-05

2. MEDIUM 166

2. MEDIUM 166

Potential Damage Mechanism(s)


SCC External Damage HTHA Liner Thinning SCC Liner SCC
Generalized None

Nom. Rem. Life [yrs]

46724 Prob. Rem. Life [yrs] 7

4631 67

Current Inspection(s)

None None

7-Fairly

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 6 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 294.0 Y 1797.1 38.100 N

17E2 INLET Asset ID Stripper Water Effluent Cooler FINFAN RU IV


Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 95244.4(Calc) 6.8

Hydrogen Sulfide (0%) 72.0

Carbon Steel \ SA-283 \ Grade: C None

0.230(Mea)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 26-Dec-11


176.4 0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


641.0 0.0 0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
4 1 1 0 0 0

Category
4 1 1 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.2 0.0 0.0 1 1 1 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

787,067

176.4

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

2. MEDIUM 319,338

4.057E-01

641.0

0.5

1 1.150E-03

1.474E+00 1,160,408

2. MEDIUM

1. LOW 905

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S Extl. Corrosion

Exceeded corrosion allowance

Prob. Rem. Life [yrs]

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/26/2011 Highly [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Max. Insp. Interval None None None

Target Driver None

User Pref. None [Y] None [N] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [N] None [Y] None [Y] None [Y] Highly [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 7 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 294.0 Y 1797.1 38.100 N

17E2 OUTLET Asset ID Stripper Water Effluent Cooler FINFAN RU IV


Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 95244.4(Calc) 6.8

Hydrogen Sulfide (0%) 53.9

Carbon Steel \ SA-283 \ Grade: C None

0.270(Mea)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 26-Dec-11


641.0 0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


641.1 0.0 0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
4 1 1 0 0 0

Category
4 1 1 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.2 0.0 0.0 1 1 1 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

787,067

641.0

1.474E+00 1,160,408

641.1

0.5

1 1.150E-03

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

2. MEDIUM

1.475E+00 1,160,589

2. MEDIUM

1. LOW 905

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S Extl. Corrosion

Exceeded corrosion allowance

Prob. Rem. Life [yrs]

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/26/2011 Highly [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Max. Insp. Interval None None None

Target Driver None

User Pref. None [Y] None [N] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [N] None [Y] None [Y] None [Y] Highly [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 8 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 25.4 Y 1210.3 2.800 N

17E2 TUBE Asset ID Stripper Water Effluent Cooler FINFAN RU IV


Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 95244.4(Calc) 6.8

Hydrogen Sulfide (0%) 53.9

Carbon Steel \ SA-214 None

0.270(Mea)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 26-Dec-11

Future Status Before Inspection Factor 18-Oct-16 Category


5 1 1 0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

3,205.1

Category
5 1 1 0 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


3,205.1 5 1 1 0

0.0 0.0

3,205.1

Category

0.0 0.0

0.0 0.0

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

787,067

3,205.1

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

3. MEDIUM HIGH 5,802,220

7.372E+00

3,205.1

3,205.1

3. MEDIUM HIGH 5,802,220

7.372E+00

3. MEDIUM HIGH 5,802,220


0

7.372E+00

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S Extl. Corrosion

Exceeded corrosion allowance

Prob. Rem. Life [yrs]

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/26/2011 Highly [N] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Risk (Total Cost) None None None

Target Driver None

User Pref. None [Y] None [N] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [N] None [Y] None [Y] None [Y] Highly [N] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 9 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 294.0 Y 1797.1 38.100 N

17E2K INLET Asset ID Stripper Water Effluent Cooler FINFAN RU IV


Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 95244.4(Calc) 6.8

Hydrogen Sulfide (0%) 72.0

Carbon Steel \ SA-283 \ Grade: C None

0.230(Mea)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 26-Dec-11


176.4 0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


641.0 0.0 0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
4 1 1 0 0 0

Category
4 1 1 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.2 0.0 0.0 1 1 1 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

787,067

176.4

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

2. MEDIUM 319,338

4.057E-01

641.0

0.5

1 1.150E-03

1.474E+00 1,160,408

2. MEDIUM

1. LOW 905

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S Extl. Corrosion

Exceeded corrosion allowance

Prob. Rem. Life [yrs]

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/26/2011 Highly [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Max. Insp. Interval None None None

Target Driver None

User Pref. None [Y] None [N] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [N] None [Y] None [Y] None [Y] Highly [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 10 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 294.0 Y 1797.1 38.100 N

17E2K OUTLET Asset ID Stripper Water Effluent Cooler FINFAN RU IV


Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 95244.4(Calc) 6.8

Hydrogen Sulfide (0%) 53.9

Carbon Steel \ SA-283 \ Grade: C None

0.270(Mea)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 26-Dec-11


641.0 0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


641.1 0.0 0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
4 1 1 0 0 0

Category
4 1 1 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.2 0.0 0.0 1 1 1 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

787,067

641.0

1.474E+00 1,160,408

641.1

0.5

1 1.150E-03

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

2. MEDIUM

1.475E+00 1,160,589

2. MEDIUM

1. LOW 905

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S Extl. Corrosion

Exceeded corrosion allowance

Prob. Rem. Life [yrs]

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/26/2011 Highly [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Max. Insp. Interval None None None

Target Driver None

User Pref. None [Y] None [N] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [N] None [Y] None [Y] None [Y] Highly [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 11 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 25.4 Y 1210.3 2.800 N

17E2K TUBE Asset ID Stripper Water Effluent Cooler FINFAN RU IV


Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 95244.4(Calc) 6.8

Hydrogen Sulfide (0%) 53.9

Carbon Steel \ SA-214 None

0.270(Mea)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 26-Dec-11

Future Status Before Inspection Factor 18-Oct-16 Category


5 1 1 0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

3,205.1

Category
5 1 1 0 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


3,205.1 5 1 1 0

0.0 0.0

3,205.1

Category

0.0 0.0

0.0 0.0

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

787,067

3,205.1

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

3. MEDIUM HIGH 5,802,220

7.372E+00

3,205.1

3,205.1

3. MEDIUM HIGH 5,802,220

7.372E+00

3. MEDIUM HIGH 5,802,220


0

7.372E+00

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S Extl. Corrosion

Exceeded corrosion allowance

Prob. Rem. Life [yrs]

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/26/2011 Highly [N] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Risk (Total Cost) None None None

Target Driver None

User Pref. None [Y] None [N] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [N] None [Y] None [Y] None [Y] Highly [N] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 12 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 914.4 5.3 N N 9.500

17V1 BOTTOM Sour Water Collecting Vessel DRUM RU IV

Asset ID

Carbon Steel \ SA-516 \ Grade: 55 Weld Overlay []

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

n-Eicosane_Crude Typical_Lubricating Oil (Liquid) None (0%) 0.9 59.4 2669.7(Calc) 0.127(Mea)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 0.2

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 4 0 0 0

Category
1 1 4 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.2 0.2 1 1 1 0

Category

641.1

642.0

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

3,169,339

641.1

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

3. MEDIUM HIGH 316,971

1.000E-01

642.2

4 1.002E-01

0.5

1 7.800E-05

3. MEDIUM HIGH 317,515

2. MEDIUM 247

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC Extl. Corrosion

Nom. Rem. Life [yrs]

34

Prob. Rem. Life [yrs]

26

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. 12/25/2011 Highly [N] No inspection No inspection No inspection 12/25/2011 None [Y] None [Y] None [Y] Highly [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver Damage Factor None None None Max. Insp. Interval

User Pref. None [N] None [Y] None [Y] None [Y] None [N]

Trad. (Non-RBI) Final Appr. None [N] Highly [N] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [N] Highly [Y]

Recommendations

Print date: 26-Dec-11 Page 13 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/1/1975 914.4 5.3 N N 9.500

17V1 TOP Sour Water Collecting Vessel DRUM RU IV

Asset ID

Carbon Steel \ SA-516 \ Grade: 55 Weld Overlay []

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 2669.7(Calc) 0.9 0.083(Mea) 59.4

Hydrogen Sulfide (1%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0

Future Status Before Inspection Factor 18-Oct-16


0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 0 4 0 0 0

Category
1 0 4 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.2 1 0 1 0

Category

641.1

642.0

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

2,386,566

641.1

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

3. MEDIUM HIGH 238,684

1.000E-01

642.0

4 1.002E-01

0.5

1 7.800E-05

3. MEDIUM HIGH 239,019

2. MEDIUM 186

Potential Damage Mechanism(s)


Generalized None Extl. Corrosion

Nom. Rem. Life [yrs]

93

Prob. Rem. Life [yrs]

40

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/25/2011 None [Y] None [Y] None [Y] Highly [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None Max. Insp. Interval

User Pref. None [Y] None [Y] None [Y] None [Y] None [N]

Trad. (Non-RBI) Final Appr. None [N] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [N] Highly [Y]

Recommendations

Print date: 26-Dec-11 Page 14 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

10/26/1974 33.4 7.0 N N 6.400

LN 17-10 AW 1 Piping PIPE-1 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

n-Eicosane_Crude Typical_Lubricating Oil (Liquid) None (0%) 0.8 59.4 2669.7(Calc) 0.014(Mea)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.6

Future Status Before Inspection Factor 18-Oct-16


0.0 2.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 0 1 0 0 3

Category
1 0 2 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 2.0 1 0 2 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

223,562

10.6

10.0

1.458E-03

12.0

3 1.650E-03

12.0

3 1.650E-03

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW 326

1. LOW 369

1. LOW 369

Potential Damage Mechanism(s)


Generalized None Extl. Corrosion

446 416 Nom. Rem. Life [yrs] Prob. Rem. Life [yrs] The fatigue factor exceeds the set damage factor limit. Fatigue

Current Inspection(s)

None None

3-Fairly

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

3-Highly None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 15 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

12/18/1974 33.4 29.0 N N 6.400

LN 17-11 AW 1 Piping PIPE-1 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

n-Eicosane_Crude Typical_Lubricating Oil (Liquid) None (0%) 19.4(Calc) 3.0 59.4

0.006(Mea)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.6

Future Status Before Inspection Factor 18-Oct-16


0.0 2.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 0 1 0 0 2

Category
1 0 2 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 2.0 1 0 2 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

393,996

2.6

2.0

1.361E-03

4.0

2 2.093E-03

4.0

2 2.093E-03

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW 536

1. LOW 825

1. LOW 825

Potential Damage Mechanism(s)


Generalized None Extl. Corrosion

Nom. Rem. Life [yrs]

1002

Prob. Rem. Life [yrs]

932

Current Inspection(s)

None None

3-Fairly

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

3-Highly None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 16 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

4/12/1974 60.3 20.0 N Y 8.700

LN 17-12 AW 2 Piping PIPE-2 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Gas) 0.8

Hydrogen Sulfide (1%) 3473.7(Calc) 0.039(Mea) 115.0

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 0.6 0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 1 0 0 0

Category
1 1 1 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.6 0.0 1 1 1 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

156,816

0.5

1.181E-04

0.6

1 1.417E-04

0.6

1 1.417E-04

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC Extl. Corrosion

19
219

1. LOW

22

1. LOW

22

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

205

Current Inspection(s)

None None

3-Fairly

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

3-Poorly None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 17 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

12/18/1974 60.3 18.3 N N 5.540

LN 17-15 A 2 Piping PIPE-2 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 240.6(Calc) 1.0 0.040(Mea) 30.0

Hydrogen Sulfide (1%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.2

Future Status Before Inspection Factor 18-Oct-16


0.0 4.2

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 4 0 0 0

Category
1 2 5 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 4.2 2.0 1 2 2 0

Category

862.5

1,602.6

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

156,816

862.7

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

2. MEDIUM 29,222

1.863E-01

1,606.8

5 3.471E-01

6.2

2 1.339E-03

3. MEDIUM HIGH

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC Extl. Corrosion

54,426

1. LOW 210

Nom. Rem. Life [yrs]

132

Prob. Rem. Life [yrs]

94

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/25/2011 None [Y] None [Y] None [Y] Highly [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None Max. Insp. Interval

User Pref. None [Y] None [Y] None [Y] None [Y] None [N]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [N] Highly [Y]

Recommendations

Print date: 26-Dec-11 Page 18 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

12/18/1974 114.3 18.3 N N 6.020

LN 17-15 A 4 Piping PIPE-4 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 240.6(Calc) 1.0 0.040(Mea) 30.0

Hydrogen Sulfide (1%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.2

Future Status Before Inspection Factor 18-Oct-16


0.0 4.2

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 4 0 0 0

Category
1 2 5 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 4.2 1.1 1 2 2 0

Category

682.6

1,162.8

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

464,717

682.8

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

2. MEDIUM 49,818

1.072E-01

1,167.0

5 1.832E-01

5.3

2 8.321E-04

3. MEDIUM HIGH

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC Extl. Corrosion

85,145

1. LOW 387

Nom. Rem. Life [yrs]

142

Prob. Rem. Life [yrs]

101

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/25/2011 None [Y] None [Y] None [Y] Highly [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None Max. Insp. Interval

User Pref. None [Y] None [Y] None [Y] None [Y] None [N]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [N] Highly [Y]

Recommendations

Print date: 26-Dec-11 Page 19 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

12/18/1974 168.3 27.0 N N 7.100

LN 17-15 A 6 Piping PIPE-6 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 240.6(Calc) 1.0 0.040(Mea) 30.0

Hydrogen Sulfide (1%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.2 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 4.2 0.1

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 1 0 0 0

Category
1 2 1 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 4.2 0.1 1 2 1 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

574,047

0.5

6.600E-05

4.3

2 5.676E-04

4.3

2 5.676E-04

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC Extl. Corrosion

38
168

1. LOW 326

1. LOW 326

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

158

Current Inspection(s)

None None

3-Fairly

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

3-Highly None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 20 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

1/20/1975 168.3 178.0 7.100 N Y

LN 17-16 A 6 Piping PIPE-6 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Gas) 240.6(Calc) 1.0 0.068(Mea) 124.8

Hydrogen Sulfide (1%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 0.7

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 0 0 0 0

Category
1 1 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.7 1 1 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

574,047

0.5

2.570E-04

0.7

1 3.597E-04

0.7

1 3.597E-04

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW 148

1. LOW 207

1. LOW 207

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC

Nom. Rem. Life [yrs]

97

Prob. Rem. Life [yrs]

93

Current Inspection(s)

None None

3-Fairly

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 21 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

10/16/1974 25.4 2.0 N N 4.550

LN 17-17 AW 1 Piping PIPE-1 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 2669.7(Calc) 0.8 0.125(Exp) 59.4

Hydrogen Sulfide (0%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


17.3 0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 5 0 0 0

Category
3 1 5 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


9.1 0.0 2 1 4 0

Category

1,602.8

1,607.6

203.4

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

223,562

1,602.8

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

3. MEDIUM HIGH

2.204E-01

1,624.9

5 2.234E-01

212.5

4 2.922E-02

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC Extl. Corrosion

49,270

3. MEDIUM HIGH

49,949

2. MEDIUM 6,532

Nom. Rem. Life [yrs]

33

Prob. Rem. Life [yrs]

25

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection 12/25/2011 12/25/2011 Fairly [Y] None [Y] None [Y] Highly [N]

None None

Inspection Plans
Thinning External Damage HTHA

Max. Insp. Interval Damage Factor None None

Target Driver None

User Pref. None [Y] None [N] None [N] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [N] None [N] None [Y] None [Y] Fairly [Y] None [Y] None [Y] Highly [N]

Recommendations

Print date: 26-Dec-11 Page 22 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

10/16/1974 48.3 2.0 N N 5.080

LN 17-17 AW 1.5 Piping PIPE-2 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 2669.7(Calc) 0.8 0.125(Exp) 59.4

Hydrogen Sulfide (0%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


1.9 0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 5 0 0 0

Category
2 1 5 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


1.9 0.0 2.9 2 1 2 0

Category

1,602.6

1,603.0

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

156,816

1,602.6

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

3. MEDIUM HIGH

2.885E-01

1,604.9

5 2.889E-01

4.8

2 8.640E-04

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC Extl. Corrosion

45,236

3. MEDIUM HIGH

45,301

1. LOW 135

Nom. Rem. Life [yrs]

37

Prob. Rem. Life [yrs]

28

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/25/2011 None [Y] None [Y] None [Y] Highly [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None Max. Insp. Interval

User Pref. None [Y] None [Y] None [Y] None [Y] None [N]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [N] Highly [Y]

Recommendations

Print date: 26-Dec-11 Page 23 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

10/16/1974 60.3 2.0 N N 8.700

LN 17-17 AW 2 Piping PIPE-2 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 2669.7(Calc) 0.8 0.125(Exp) 59.4

Hydrogen Sulfide (0%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 4 0 0 0

Category
1 1 4 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.0 0.3 1 1 1 0

Category

641.4

649.7

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

156,816

641.4

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

2. MEDIUM 18,105

1.155E-01

649.7

4 1.169E-01

0.5

1 9.000E-05

2. MEDIUM 18,339

1. LOW

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC Extl. Corrosion

14

Nom. Rem. Life [yrs]

66

Prob. Rem. Life [yrs]

48

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/25/2011 None [Y] None [Y] None [Y] Highly [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None Max. Insp. Interval

User Pref. None [Y] None [Y] None [Y] None [Y] None [N]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [N] Highly [Y]

Recommendations

Print date: 26-Dec-11 Page 24 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

12/18/1974 48.3 2.0 N Y 5.080

LN 17-18 AW 1.5 Piping PIPE-2 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 3473.7(Calc) 0.8 0.125(Exp) 124.8

Hydrogen Sulfide (1%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


1.9 0.7

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 0 0 0 0

Category
2 1 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


1.9 0.7 2 1 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

156,816

0.5

9.000E-05

2.6

2 4.680E-04

2.6

2 4.680E-04

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC

14
37

1. LOW

73

1. LOW

73

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

28

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 25 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

12/18/1974 60.3 5.0 N Y 8.700

LN 17-18 AW 2 Piping PIPE-2 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Liquid) 3473.7(Calc) 0.8 0.125(Exp) 124.8

Hydrogen Sulfide (1%)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 0.7

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 0 0 0 0

Category
1 1 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.7 1 1 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

156,816

0.5

9.000E-05

0.7

1 1.260E-04

0.7

1 1.260E-04

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC

14
66

1. LOW

20

1. LOW

20

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

48

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 26 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

6/12/1974 88.9 18.3 N Y 5.490

LN 17-5 AW 3 Piping PIPE-4 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Gas) 0.8

Hydrogen Sulfide (1%) 3473.7(Calc) 0.030(Mea) 124.8

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 0.6

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 0 0 0 0

Category
1 1 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.6 1 1 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

464,717

0.5

7.850E-05

0.6

1 9.420E-05

0.6

1 9.420E-05

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC

36
175

1. LOW

44

1. LOW

44

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

124

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 27 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

6/12/1974 114.3 59.0 N Y 6.000

LN 17-5 AW 4 Piping PIPE-4 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Gas) 0.8

Hydrogen Sulfide (1%) 3473.7(Calc) 0.030(Mea) 124.8

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 0.6

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 0 0 0 0

Category
1 1 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.7 1 1 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

464,717

0.5

1.520E-04

0.6

1 1.823E-04

0.7

1 2.127E-04

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC

71
193

1. LOW

85

1. LOW

99

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

190

Current Inspection(s)

None None

5-Fairly

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 28 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

6/12/1974 168.3 67.0 N Y 7.100

LN 17-5 AW 6 Piping PIPE-6 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Gas) 0.8

Hydrogen Sulfide (1%) 3473.7(Calc) 0.030(Mea) 124.8

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0 0.0

Future Status Before Inspection Factor 18-Oct-16


0.0 0.6

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 1 0 0 0 0

Category
1 1 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 0.7 1 1 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

574,047

0.5

9.672E-05

0.6

1 1.161E-04

0.7

1 1.354E-04

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW

Potential Damage Mechanism(s)


Generalized HIC/ SOHIC - H2S and/or SSC

56
225

1. LOW

67

1. LOW

78

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

200

Current Inspection(s)

None None

2-Fairly

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 29 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

12/18/1974 60.3 18.3 N Y 5.540

LN 17-823 N 2 Piping PIPE-2 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Gas) None (0%) 3.3(Calc) 3.0 210.0

0.001(Exp)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0

Future Status Before Inspection Factor 18-Oct-16


0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 0 0 0 0 0

Category
1 0 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 1 0 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

156,816

0.5

1.080E-04

0.5

1 1.080E-04

0.5

1 1.080E-04

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW

Potential Damage Mechanism(s)


Generalized None

17
4317

1. LOW

17

1. LOW

17

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

3024

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 30 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

12/18/1974 88.9 18.3 N Y 5.490

LN 17-823 N 3 Piping PIPE-4 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: E/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Gas) None (0%) 3.3(Calc) 3.0 210.0

0.001(Exp)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0

Future Status Before Inspection Factor 18-Oct-16


0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 0 0 0 0 0

Category
1 0 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 1 0 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

464,717

0.5

7.850E-05

0.5

1 7.850E-05

0.5

1 7.850E-05

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW

Potential Damage Mechanism(s)


Generalized None

36
4237

1. LOW

36

1. LOW

36

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

2968

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 31 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

12/18/1974 168.3 40.0 N Y 7.100

LN 17-823 N 6 Piping PIPE-6 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Water (Gas) None (0%) 3.3(Calc) 3.0 210.0

0.001(Exp)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0

Future Status Before Inspection Factor 18-Oct-16


0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 0 0 0 0 0

Category
1 0 0 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 1 0 0 0

Category

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

574,047

0.5

6.600E-05

0.5

1 6.600E-05

0.5

1 6.600E-05

Risk (Total Cost) [USD/Yr] Thinning SCC External Damage HTHA Liner Thinning SCC Liner SCC

1. LOW

Potential Damage Mechanism(s)


Generalized None

38
5346

1. LOW

38

1. LOW

38

Nom. Rem. Life [yrs]

Prob. Rem. Life [yrs]

3744

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection No inspection None [Y] None [Y] None [Y] None [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None None

User Pref. None [Y] None [Y] None [Y] None [Y] None [Y]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y]

Recommendations

Print date: 26-Dec-11 Page 32 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD

Eqp. ID Eqp. Name Eqp. Type Production Unit

Equipment Summary Sheet

Service Start Date Diameter [mm] Length/Height [m] Thickness [mm] PWHT [y/n] Insulated [y/n] Material Lining Type

11/28/1974 33.4 63.0 N N 4.600

LN 17-824 A 1 Piping PIPE-1 RU IV

Asset ID

Carbon Steel \ SA-53 \ Grade: S/B None

Chemical Toxic Chemical Inventory Group[Kg] Op. Pres. [kgf/sqcm (a)] Op. Temp. [C] Corr. Rate-Expert [mm/Yr]

Hydrogen (Gas) 1.1(Calc) 1.4 38.0

Hydrogen Sulfide (0%)

0.000(Exp)

Analysis Level Consequence-Lookup Likelihood-Detailed Dmg. Mech.

Current Status 25-Dec-11


0.0

Future Status Before Inspection Factor 18-Oct-16


0.0

Thinning SCC External Damage HTHA Brittle Fracture Fatigue Likelihood

Factor

Category
1 0 4 0 0 0

Category
1 0 4 0

Future Status After Inspection (Final Appr.) 18-Oct-16 Factor


0.0 5.3 1 0 2 0

Category

655.1

901.3

CoF (Total Cost) [USD] LoF[Events/Yr] Risk Rank (Overall)

707,519

655.1

Risk (Total Cost) [USD/Yr] Thinning

2. MEDIUM 526,907

7.447E-01

901.3

5.3

2 6.025E-03

1.025E+00 724,929

2. MEDIUM

1. LOW 4,263

Potential Damage Mechanism(s)


SCC External Damage HTHA Liner Thinning SCC Liner SCC
Generalized None Extl. Corrosion

Nom. Rem. Life [yrs]

44509 Prob. Rem. Life [yrs] 7

3115 70

Current Inspection(s)

None None None

External Damage HTHA Inspection Date ORBIT Sugg. No inspection None [Y] No inspection No inspection No inspection 12/25/2011 None [Y] None [Y] None [Y] Highly [Y]

None None

Inspection Plans
Thinning External Damage HTHA

Target Driver None None None None Max. Insp. Interval

User Pref. None [Y] None [Y] None [Y] None [Y] None [N]

Trad. (Non-RBI) Final Appr. None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [Y] None [N] Highly [Y]

Recommendations

Print date: 26-Dec-11 Page 33 of 33

RBI Pertamina RU IV Cilacap UNIT17~1.ORD