Anda di halaman 1dari 11

C

ONTENTS

02 Overview 03 Product Category


05 JDCF7-110W High Voltage Potential Transformer 07 LB6-110W HV Current Transformer 09 LB7-220W HV Current Transformer 11 LB7- 220W Transient Protection Current Transformer 13 LVB-110W and LVB-220W HV Current Transformer 15 LGB-110W Dry-type HV Current Transformer
( Production Temporanly Halted )

Overview

Product Category

Overview
Initially founded in 1936, Nanjing Electric (Group) Co., Ltd. (formerly Nanjing Electric Porcelain Factory) was reconstructed to a wholly-funded subsidiary of Baiyun Power Group in 2004, and was the manufacture base of HV instrument transformer. Now it is an ISO 9001-2000 certified high-tech enterprise in Nanjing, and ever been awarded Pacemaker in the Chinese Electrical Porcelain Industry, National Quality and Efficiencyoriented Enterprise., etc. Its Thunder and Lightning trademark registered in 1973 is well known at home and abroad.
Nanjing Electric:

Sales achievements
In 2005: 588 sets of 110kV instrument transformers and 243 sets of 220kV bushing transformers; In 2006: 1069 sets of 110kV instrument transformers, among which 303 sets are exported; 165 sets of 220kV bushing transformers, among which 57 sets are exported; In 2007: 306 sets of 110kV bushing transformers and 69 sets of 220kV bushing transformers; In 2008: 171 sets of 110kV bushing transformers and 12 sets of 220kV bushing transformers; In 2009: 285 sets of 110kV bushing transformers and 6 sets of 220kV bushing transformers; In 2010: 800 sets of 110kV bushing transformers and 9 sets of 220kV bushing transformers.

The electromagnetic instrument transformers include HV oilimmersed current transformer and HV oil-immersed cascade type voltage transformer. There are two kinds of current transformers, namely upright type and upside-down type, of which the voltage class includes 110kV and 220kV respectively. Since its first oil-impregnated paper condenser type transformer & wall bushing in 1958 in our country, with more than 50 years of experience in the production and manufacturing of oilimpregnated paper insulation condensers, the company has had firm foundation in the manufacturing of paper condenser type transformer & wall bushing and HV instrument transformer. Since the end of 1980s, in order to meet the new requirements made continuously by users, the company has successively developed LB series, LVB series and JDCF series instrument transformers which represent an advanced level in our country. Since the 1970s when the company developed 110kV and above HV instrument transformers, the company has produced and delivered more than 30000 current transformers and voltage transformers by now, becoming one of the important domestic manufacturers of HV instrument transformers. For a long time, the company has been attaching great importance to technology introduction, and has known and mastered domestic and overseas manufacturing technology

of oil-impregnated paper insulators, which helped it form its own unique manufacturing technology. With all these efforts, its technical criteria for current transformer have been leading among similar products at home and abroad; the product electric property and insulation margin is advanced among domestic products and even superior to foreign products. Nanjing Electric has set up the production technology which meets the international standard as well as the high voltage laboratory approved by the State Certification and Accreditation Administration. The perfect manufacturing and test equipment and abilities guarantee the product quality. The company has passed ISO 9001 quality management system certification, ISO 14001 environmental management system certification, OHSAS 18001 occupational health and safety management system certification and PCCC product certification, and has the certification of metro-logical guarantee confirmation for instrument transformers as well as CMC license for manufacturing measuring instruments. Voltage class for the instrument transformers of Nanjing Electric is 110kV and 220kV; current range is 100A~3000A; Other technical parameters can all meet the latest standards of IEC and GB. Application Electromagnetic instrument transformer includes current transformer and inductive voltage transformer by application. The former one is a kind of special transformer exclusively used for transforming current, and the latter one is a kind of special transformer exclusively used for transforming voltage and is applicable to electrical measurement and relay protection in AC power system. Applied standard GB and IEC standard Structure The current transformers are mainly HV oil-immersed current transformers. There are two types of it, namely, vertical type and inverted type. The product is composed of expander, oil conservator, primary outgoing feeder, bushing, oil tank (or pedestal), secondary outlet box, transformer body (including winding and product main insulation), transformer oil etc. For the erected type, the secondary winding is fixed beneath the product, and the primary winding which has HV potential is led under the primary winding and is sufficiently insulating to the secondary winding and parts and components of other earth potential; For the inverted type, the secondary winding which has the earth potential is placed on the product, and the secondary winding is sufficiently insulating externally, which can separate it from the primary winding which has HV potential. Inductive voltage transformer adopts oil-immersed cascade structure and is composed of expander, oil conservator, primary outlet, bushing, oil tank (or pedestal), secondary outlet box, transformer body (including winding and product main insulation), transformer oil etc.

Product Category

02

Instrument Transformers

03

Product Category
Principles Electromagnetic instrument transformer uses the principle of electromagnetic transformation, and transforms the hardly measured voltage and current of the power grid into low voltage and low current with specified transformation ratio and accuracy requirement, and then transmits it to the metering instrument, measuring instrument and relay protection at secondary side. Model Explanation: LB6-110W: 110kV Oil-immersed vertical type current transformer LB7-220W: 220kV Oil-immersed vertical type current transformer LVB-110W: 110kV Oil-immersed inverted type current Structure Diagram
Primary Expander Expander outgoing feeder Expander Primary outgoing feeder Oil conservator Bushing Primary outgoing feeder Oil conservator Bushing Oil conservator Bushing

Product Category

JDCF7-110W High Voltage Potential Transformer


transformer LVB-110W: 220kV Oil-immersed inverted type current transformer JDCF-110W:110kV Single-phase oil-immersed inductive voltage transformer L- current transformer, V-inverted type, B- with protection level J- voltage transformer, D- single phase, C- cascade type with residual (zero sequence) winding, F- secondary winding with separated measurement and protection W-pollution proof type, 6 (7)-design No., 110 (220)- voltage class (kV) Model description Features Metal expander with pressure-relief device Three secondary windings with separated measuring level and
Pollution proof level Rated voltage (kV) Design No. Separated secondary winding Cascade type Single-phase Voltage transformer

JDCF7-

protection level Single silk covered enamel wire with 0.25 primary conductor Measuring level includes level 0.5 and level 0.2 Working magnetic flux density is low, which can meet the requirements of 1.6 times of rated voltage Use high quality bracket

Major technical parameters

Product model
Rated primary voltage KV Measuring level Rated secondary voltage V Protection level Residual voltage Measuring level Rated output and accuracy class Protection level Residual voltage Thermal limit load VA Rated voltage factor Primary winding to earth Power frequency withstand voltage kV Primary winding to earth In between the secondary windings

JDCF7-110W
100/ 3 100/ 3 100/ 3 100 75~100VA level 0.2 / 150VA level 0.5 300VA level 3p 200VA level 3p 2000 1.6times30s 200 5 2 <2 <10 550 633 0.2MPa no leakage (tested before expander installation) 3150 3960 140/550

Secondary outlet box Secondary outlet box Oil tank Pedestal Secondary outlet box Pedestal

Medium loss factor % Partial discharge level pC Standard lightning full wave impulse voltage kv Lightning carrier wave impulse voltage kv Leak tightness

Figure 1: Oil-immersed Vertical Type Current Transformer

Figure 2: Oil-immersed Inverted Type Current Transformer

Figure 3: Oil-immersed (Cascade Type) Inductive Voltage Transformer

Creepage distance mm Weight of oil / gross weight kg


Note: It can be designed with two secondary windings. The load and accuracy can be adjusted according to users needs.

Applicable environment and places: outdoor, ambient temperature +40C~40C, working altitude: less than 3000m applied to various pollution class, AC power system with the neutral point effectively grounded.

Characteristics: superior and stable electrical property, high insulation margin.

04

Instrument Transformers

05

Product Category
Ordering instructions 1. Model and rated voltage 2. Voltage ratio (arranged in secondary winding), corresponding accuracy class and load of each secondary winding 3. Creepage distance 4. Other special requirements shall be noted specially Example: JDCF7-110W/110KV/100/ 3 V/100 3 V/100 3 V (0.2 or 0.5/P/ P); level 0.2, 5VA; level 3p 200VA; Creepage distance 3150; with metal expander. JDCF7 series voltage transformer has two master secondary windings with separated measurement and protection level, which can better meet the national code for electrical measurement, and provide conditions for the accurate metering of electrical measurement. This series of products adopt larger insulation design degree and high quality bracket with explosive-proof pressure-relief device and annealing techniques for cold rolled silicon steel to improve the core curve of magnetization and decrease the probability of ferromagnetic resonance and improve the ability to resist short term syntony. Applied standard GB1207 and IEC60044-2 Product model

Product Category

LB6-110W HV Current Transformer


Applied Standard This product refers to GB1208 Current Transformer and at the same time meets the regulations of IEC60044-1 Current Transformer. Product structure This product is of oiled paper capacitance omniseal structure, and is composed of primary winding, secondary winding, oil tank, oil conservator, porcelain, expander and high quality transformer oil.
Major technical parameters

Technical data Item

LB6-110W (LCWB6-110W) series


110 126/230/550 1 2*150 2*400 2*100 2*150 2*400 2*300 2*750 2*200 2*300 2*750 2*600 2*800 2*500 2*600 2*800 P/P/P0.5 ( or 3-1 )( or 0.2, 0.5 ) P/P/0.5/0.2 P/P/P/P ( or 0.5 ) /0.2 ( or 0.5) S1-S3: 40VA 50VA 30VA 5P20 S1-S2: 20VA 25VA 15VA 5P20 5 ( 10 ) P20 S1-S3: 0.2S ( 0.5 ) level 0.2 ( 0.5 ) level 30VA 50VA FS5 0.2S ( 0.5 ) level S1-S2: 0.2S ( 0.5 ) level 15VA 25-30VA FS5 2*100 2*200 2*500 13.5-50/4 34.5-125 0.5 10 3000N 3150/3906 420kV withstand voltage for1min, partial discharge under 210kv is 6pC 150/550 5

Outline drawing and dimensions


I-V characteristic curve of HV PT Percentage of rated Direction A secondary voltage

Rated voltage KV Insulation level KV Rated secondary current A Rated primary current A Accuracy class combination Protection level Rated secondary load and aaccuracy limit factor

Measuring level Rated secondary load and instrument security factor


Secondary exciting current Io Direction A

Short-time thermal current kA/s Peak withstand current ks Dielectric loss % Partial discharge pC Primary terminal load (3D) Creepage distance mm Insulation margin test Weight of oil / gross weight kg

Note: the secondary windings of the product can be combined freely as required by users. Direction B

Performance characteristics 1. The starting voltage of partial discharge is high and dielectric loss is low; it has relatively high insulation margin (see the table) and operational safety; ex-works controlling values of product dielectric loss and partial discharge are all higher than the industry standard and national standard. 3. All secondary windings have taps; there are 3-5 windings; measurement accuracy class can be 0.2s, FS5. 4. The product has strong ability in resisting pollution and environmental corrosion; its flashover distance of protective insulation is large; creepage distance rate can be 31mm/kV; it can be used in the places with the altitude up to 3000m. 5. Horizontal transport structure for convenient transport.

Direction B JDCF7-110W high voltage potential transformer (omniseal of metal expander, large and small umbrella structure)

2. It has realizable leak tightness, and has been subject to the strict positive pressure (water bath, nitrogen pressure 0.2Mpa) and negative pressure leakage check.

06

Instrument Transformers

07

Product Category

Product Category

Outline drawing and dimensions


Direction B
Primary terminal

LB7-220W HV Current Transformer


This product is of oiled paper capacitance omniseal structure, and is composed of primary winding, secondary winding, tank, conservator, bushing, expander and high quality transformer oil.
Major technical parameters

Product model
Rated voltage KV Rated insulation level KV Rated secondary current A Rated primary current A Accuracy calss combination Rated load of protection level and accurate limitation factor Rated load of measuring level and instrument security factor Dynamic current kA Dielectric loss ( tan ) Partial discharge pC Creepage distance mm Weight of oil / gross weight kg Elevation m Primary terminal withstand load N L1 Overall dimension mm L2 L3 H Installation dimension mm
Note:

LB7-220W
220 256/460/1050 5/1 2x800 and below B/B/B/0.5/0.2(or 0.2S) S1-S3 S1-S2 S1-S3 S1-S2 50VA 5P30 50VA 5P or 25VA 5P30 40-60VA 0.2(0.5)FS5 20-30VA 0.2(0.5)FS5 31.5-50 80-125 0.5%, Bushing tap to ground 1.5% 252kv below 8 6300,7812 320/1250 2000 3000,4000 3830 3290 2010 780 610*400 4160 3540 2170 1070 610*500 6300,7812 500/2000 60VA 5P30 60VA 5P15 or 30VA 5p30 40VA 0.2(0.5)FS5 20VA 0.2(0.5)FS5 40-63 100-160 2x1000-2x1250

Short-time thermal current kA/3S

Direction A

Axb

1. Accuracy class of current transformer can be the combination of level P, level 0.5, level 0.2 or level 0.2S as required by users. 2. When the rated secondary current is 1A, it's suggested that the measuring level secondary load is 20/10, or be designed according to user requirements. 3. Performance parameter of measuring level and protection level can be designed according to user requirements.

Performance characteristics 1. The partial discharge is small and dielectric loss is low and its insulation is highly reliable; ex-works controlling values of product dielectric loss and partial discharge are all beyond industry standard and national standard. 2. It is installed with fine primary overvoltage protection device, which can effectively prevent the switching overvoltage from damaging the major insulation suddenly and improve the product reliability. 3. It has reliable leak tightness, and the product has been subject to several leakage checks with water bath method and negative pressure method. 4. There are at most 7 secondary windings, all of which have center taps; measuring level is 0.2FS5 and protection level is 5P30. 5. Horizontal transport structure for convenient transport. 6. The creepage distance ratio can be 20-31mm/kV. 7. Advanced design, sophisticated technology; complete detection to ensure the superior electrical insulation performance.

LB6-110W (the original LCWB6-110W) HV current transformer (Omniseal metal expander, large and small umbrella structure)

08

Instrument Transformers

09

Product Category

Product Category

Outline drawing and dimensions

LB7- 220W Transient Protection Current Transformer


This product is of oiled paper capacitance omniseal structure, and is composed of primary winding, secondary winding, tank, conservator, bushing, expander and high quality transformer oil.
Major technical parameters

Product model
Rated voltage KV Rated insulation level KV Rated secondary current A Rated primary current A Accuracy class combination

LB7-220W
220 252/460/1050 5 (or 1) 2x1000 B/B/B/0.2 (0.2S) /TPY/TPY 2x1250 B/0.2 (0.2S) /TPY/TPY/TPY/TPY

Primary terminal
( plate cut, cooper product )

S1-S3 S1-S2 S1-S3 Rated load of measuring level and instrument security factor S1-S2 Short-time thermal current kA/3S Peak withstand current kA Rated load of protection level and accurate limitation factor Product dielectric loss ( tan ) Partial discharge pC Creepage distance mmd Weight of oil / gross weight kg Elevation m Primary terminal withstand load N

50VA 5P30 25VA 5P30 50VA FS5 (or according to user requirements) 30VA FS5 (or according to user requirements) 31.5 80-160 0.5%, Bushing tap to ground 1.5% 8 6300,7812 600/2500 Below 3000 4000

below2x800A

Product model

LB7-220W
Kssc 10~20 10~15 C-0.1s-O-0.5s-C-0.1s-0 0.06(0.1) 700x600 or 600x600 Rated load VA Working cycle Tp.s Axb

Aluminium plate
TPY level parameter

Installation dimension mm
Note:

1.Accuracy class of current transformer can be the combination of level 5P, level 0.2, or level 0.5 as required by users. 2.Performance parameters like the accuracy class and load of measuring level and protection level can be designed according to user requirements.

Performance characteristics
Mounting hole

LB7-220W HV current transformer

1. The product partial discharge is less and dielectric loss is low and its insulation is highly reliable; ex-works controlling values of product dielectric loss and partial discharge are all beyond the national standard. 2. It is installed with fine primary overvoltage protection device, which can effectively prevent the switching overvoltage from damaging the major insulation suddenly and improve the product reliability. 3. It has reliable leak tightness, and has been subject to several leakage checks with water bath and negative pressure method.

4. Secondary windings can be equipped with center taps and the measuring level can be 0.2FS5; TPY level can be 4 at most. 5. Horizontal transport structure for convenient transport 6. The creepage distance ratio is 20-31mm/kV. 7. Advanced design, sophisticated technology, complete detection, to ensure the superior electrical insulation performance.

10

Instrument Transformers

11

Product Category

Product Category

Outline drawing and dimensions

LVB-110W and LVB-220W HV Current Transformer


This product is of oiled paper capacitance slight positive pressure omniseal structure; it's composed of secondary winding (major insulation), primary winding, oil tank, outer insulation covering, metal expander, pedestal, high quality transformer oil etc. Refer to the figure for its overall shape. Through primary series connection, parallel switch and secondary tap, this product can have more than three rated current. For example, 2x1250/5A,its rated current can be:primary series connection;2500/5A;primary parallel connection:1250/5A, tap 750/5A
Major technical parameters

Primary connecting terminal


( plate cut, aluminium alloy )

Product model
Rated voltage KV Rated insulation level KV Rated secondary current A Rated primary current A Accuracy class combination Secondary performance ( protection level ) Level B Level B Level 0.2 Level 0.2s Full turn/tap VA Accurate limitation factor ( ALF ) Full turn/tap VA Accurate limitation factor (ALF) Full turn/tap VA Instrument security factor (FS) Short-time thermal current kA/3S Peak withstand current (partial) kA Product dielectric loss (tan q) Partial discharge pC Creepage distance mm Flashover distance mm Elevation m Primary terminal withstand load Other directions
Note:

LVB-110W
126 126/230/550 5(1) 2*300~2*1250 B/B/B/0.5/0.2s --50/25 5P25,5P30 ----30~50/20~25 20~63 50-160 0.4% 10below 185kv ) 3150,3910 1180 Below 3000 2500~4000 2500~4000 80/350 2*1250/5 40/25 ( 50/25 ) 5P20 ( 5P15 ) 60/30 ( 50/25 ) 5P25 ( 5P30 ) 60/30 5 2*1250/1 30/20 5P20 40/25 5P25 40/20 5

LVB-220W
220 252/460/1050 5 ( or 1) 2*1250,2*750,2*1500 B/B/B2/B2/0.2 2*750/5,2*1500/5 50/30 5P20 60/30 5P30 60/30 5 2*750/1,2*1500/1 30/20 5P20 40/25 5P30 40/20 5

2x750A;31.5-50; others 40-63 2x750A;00-125; others 100-160 0.4%,Zero tap to ground 0.7% 10 ( 300kv ) 6300,7812 2260 Below 3000 4000N 4000N 200/800

Installation dimensional drawing

Horizontal direction Other directions

Weight of oil/ gross weight KG

1.Accuracy calss of current transformer can be the combination of level 5P, level 0.2, or level 0.5 as required by users. 2.Performance parameters like the accuracy class and load of measuring level and protection level can be designed according to user requirements. 3.When the rated secondary current is 1A, it's suggested that the measuring level secondary load is 20/10, or be designed according to user requirements.

Mounting hole

Performance characteristics 1. It has reliable leak tightness, and is subject to strict positive pressure and negative pressure leakage check. 2. The partial discharge is small and dielectric loss is low; exworks controlling values of product dielectric loss and partial discharge are all beyond the industrial and national standard. 3. The major insulation is reliable and insulation margin is high; the product is of anti-explosion structure design. 4. All secondary windings can be equipped with center taps; measuring can be analyzed according to class 0.2S and FS5. 5. The product has strong ability to resist pollution and environmental corrosion and is free of special maintenance within 10 years. 6. The product has high flashover voltage; the minimum creepage distance is 5040mm and the maximum creepage distance can be changed according to users requirements; it can be used in the places with altitude up to 3000m.

LB7-220W Transient protection current transformer

12

Instrument Transformers

13

3710 (Height of expander 370)

Product Category

Product Category

Outline drawing and dimensions

LGB-110W Dry-type HV Current Transformer


Technical parameters Rated voltage: 110KV Rated current: 100-2500A Rated frequency: 50Hz Current ratio: 100-2500/5A or 100-2500/1A Ambient conditions Applicable indoor and outdoor Ambient temperature: maximum temperature +40C, minimum temperature - 40C Sea level elevation: 1000Csupply and requisitioning parties make an agreement when the elevation is above 1000m) Environmental pollution level: level III and IV (user's special requirements can be indicated on the contract)

Direction A

Rated output capacity: 20-50VA Accuracy class: 0.2S, 0.2, 0.5s, 0.5 or 5P, 10P Accurate limitation factor: 5, 10, 15, 20, 25, 30 Instrument security factor: 5, 10 Number of windings: 1-6

Direction A schematic drawing

Earthing bolt

Direction A

Direction B

Direction A

Direction A

Direction B

Dimension of primary terminal


(aluminum alloy)

Direction A
Nameplate

Secondary terminal block

Gravitv position

Oil nozzle

Condenser panel 5

LVB-110W HV current transformer

LVB-220W HV current transformer

14

Instrument Transformers

15

Product Category
Type test, routine test and special test All type tests and special tests are finished per regulations of GB1208 Current Transformer and IEC60044-1 Current Transformer; major items are as follows:
Rated insulation level and partial discharge test of primary winding

Rated insulation level Equip-ment maximum voltage (kv)

Partial discharge level

Power frequency Lightning impulse Lighting impulse withstand voltage withstand voltage test voltage (kv) (kv) (kv)
230 550 633

Partial discharge measure-ment voltage (kv)


87

Partial discharge (pC)

126

Determination of capacitance and dielectric loss factor Under 10kv and Um/ 3 V voltage, tan 0.004

During operation, secondary windings shall not be in breaking circuit; Otherwise, t high voltage would be generated and endanger the safety. Bushing tap of primary winding and a terminal of secondary winding shall be grounded. Peak Transport and installation It shall be packed with damping material during transportation to prevent strenuous vibration. During loading and unloading, protect the umbrella skirt from being damaged. Ex-works documents of current transformer include: quality certificate, test report and installation and instruction manual, which are all put into the package and will be transported together with the product. Ordering instructions In order to submit an order, the following data should be stated: rated voltage, rated current, current ratio, number of secondary windings of each current transformer, winding measuring accuracy (0.2s, 0.2, 0.5s, 0.5), accuracy class of protection winding (5P, 10P), and accuracy limitation factor (5, 10, 15, 20, 25, 30), output capacity of secondary windings (20-50VA), environmental pollution level and installation mode when an order is placed. The product can also be designed according to the special requirements of user.

Rated short-time thermal current and peak withstand current Rated short-time thermal current: 31.5ka, 4n withstand current: 80KA Winding temperature rise limitation: 8.5K Secondary winding mark test, frequency withstand test, inter-turn overvoltage test and error determination can meet the regulations of GB1208 and IEC60044-1. Mechanical strength test: 2000N, 60a Acceptance check and maintenance Primary winding of each current transformer has been subject to AC withstand voltage, partial discharge, dielectric loss factor measurement and bushing tap withstand test before leaving factory. Secondary windings have been subject to mark test, insulation test and error detection. At the site, test can be conducted in accordance with DL/T-596 Preventive Test Code for Electric Power Equipment. Generally, current transformer is free of maintenance; only the capacitance and dielectric loss factor of primary winding should be measured every two or three years (due to the impact of site temperature on the outer insulation surface, dielectric loss factor tam q may increase, so it can be dried with hot wind or in the sun before the test).

16

Instrument Transformers

Anda mungkin juga menyukai