DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15010 Identification Number

25/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment 20FT CONTAINER

SWL

WHLU 720618/6

A steel construction 20ft Container

20950kg

LOCATION : UPPER DECK PORT SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

ISO Corner lifting points

Lifting points shall be replaced with padeyes Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Pacific Drilling
Pacific Scirocco
We hereby certify that on 25/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15011 Identification Number

24/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE SET FOR TOOL BASKET (PWS/TB/003)

SWL

SHACKLE ID: JR 9456 JR 9459 JR 9468

3pcs

Bow Safety pin shackle

4.75 Tons

LOCATION : SACK ROOM


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induced at the crown of shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Pro Fluid Well Services


Pacific Scirocco
We hereby certify that on 24/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15012 Identification Number

24/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SLING SET FOR TOOL BASKET (PWS/TB/003)

SWL

Sling ID: 6911/1

1set

13mm X 2.65m X 4 legged sling c/w Quad master link assembly with ferrule secured thimble eyes at all ends

4.4 Tonnes @ 0 0-90

LOCATION : SACK ROOM


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Internal dimension of master link less than 270mm X 140mm

Remove from service

(Not Fit for Use)


Name and address of equipment owner: Address of premises where Test / Examination was held:

Pro Fluid Well Services


Pacific Scirocco
We hereby certify that on 24/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15013 Identification Number

24/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment CHAIN BLOCK

SWL

BTC 03832-2

1pc

Chain Block fitted with 5mm X 6.3m Single Chain fall

0.5 Tonne

LOCATION : BOSUN STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Mal function

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Pacific Drilling
Pacific Scirocco
We hereby certify that on 24/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15014 Identification Number

24/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment CHAIN BLOCK

SWL

BTC 03832-3

1pc

Chain Block fitted with 5mm X 6.3m Single Chain fall

0.5 Tonne

LOCATION : BOSUN STORE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Severe pitting on Load Chain

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Pacific Drilling
Pacific Scirocco
We hereby certify that on 24/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15015 Identification Number

23/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty.

Description of Equipment WIRE ROPE SLING

SWL

964602-0-1-1

1pc

1 (26mm) X 299ft X Single leg sling c/w thimble eyes both ends

9.8 Tonnes

LOCATION : RISER DECK STBD SIDE


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Inner Core Exposure

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Pacific Drilling
Pacific Scirocco
We hereby certify that on 23/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15016 Identification Number

22/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

BTC 03827-1

1set

20mm X 1.55m X 4 legged sling c/w Quad master link assembly with ferrule secured thimble eyes at all ends

10.5 Tonnes @ 0 0-90

LOCATION : FUNNEL DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Internal dimension of master link less than 270mm X 140mm Inadequate dead end protrusion on one leg

Remove from service

(Not Fit for Use)


Name and address of equipment owner: Address of premises where Test / Examination was held:

Pacific Drilling
Pacific Scirocco
We hereby certify that on 22/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15017 Identification Number

22/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment WIRE ROPE SLING

SWL

PSO-009/1

1set

20mm X 2.52m X 4 legged sling c/w Quad master link assembly with ferrule secured thimble eyes at all ends

9.71 Tonnes @ 0 0-45

LOCATION : FUNNEL DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Concentrated broken wires on one leg

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Pacific Drilling
Pacific Scirocco
We hereby certify that on 22/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15018 Identification Number

22/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

SR 68

1pc

Bow safety pin shackle

6.5 t

LOCATION : FUNNEL DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induce at crown of shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Pacific Drilling
Pacific Scirocco
We hereby certify that on 22/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15019 Identification Number

22/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

SR 60

1pc

Bow safety pin shackle

6.5 t

LOCATION : FUNNEL DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induce at crown of shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Pacific Drilling
Pacific Scirocco
We hereby certify that on 22/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15020 Identification Number

22/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

SR 69

1pc

Bow safety pin shackle

6.5 t

LOCATION : FUNNEL DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induce at crown of shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Pacific Drilling
Pacific Scirocco
We hereby certify that on 22/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15021 Identification Number

22/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

SR 75

1pc

Bow safety pin shackle

6.5 t

LOCATION : FUNNEL DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Stress induce at crown of shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Pacific Drilling
Pacific Scirocco
We hereby certify that on 22/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

15022 Identification Number

22/02/2013

CHRISTOPHER DIESERU

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

0137/D

1pc

Bow safety pin shackle

4.75 t

LOCATION : FUNNEL DECK


Particulars of defects found which are, or could, become a danger to persons or none Particulars of any repair, alteration to remedy defect or none

Wrong pin and Stress at Crown of shackle

Remove from service Address of premises where Test / Examination was held:

(Not Fit for Use)


Name and address of equipment owner:

Pacific Drilling
Pacific Scirocco
We hereby certify that on 22/02/2013 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: CHRISTOPHER DIESERU Conducting: Examination only