Anda di halaman 1dari 2

PROVIDING SAFETY SOLUTIONS

MILLENNIUM SERIES LOW POWER GAS DETECTORS


Combustible and Toxic Gas Detection

SensorGuard Sensor Management 0 to 100% LEL, Full Combustible Range Operating Temperature Range -50C to +85C (-58F to +185F) Analog, Relay or Digital Ouput Configurations Intuitive Menu System, Calibrations 90 Seconds From Start to Finish Explosion-proof, Class 1, Division/Zone 1 Approved CSA, NRTL/C and IEC Certifications 10.5 to 32 Vdc Operating Voltage

Net Safetys Millennium Low Power Combustible and Toxic Gas detectors are the only industrial gas detectors designed to draw as little as 32 mA. Developed in response to customer demand and intended for sites with limited primary or secondary power, the Millennium can be paired with a Catalytic Bead Combustible sensor, a variety of Toxic gas sensors and with our stand-alone SolarShield monitoring systems.

The Millennium Low Power is an excellent choice for locations where even the smallest continuous load can be expensiveinstallations where power is supplied by a DC or solar powered uninterruptible power source. To obtain the lowest load possible, the Millennium is manufactured with solid state relays and the ability to dim the display and switch off the 4-20 mA output circuitry. Although requiring considerably less power than other industrial detectors, the Millennium does not sacrifice features or functionality. The compact and explosion-proof Millennium has a power disconnect switch to simplify maintenance, a scrolling LED display to facilitate calibration and configuration, and an internal push button and external magnetic switch for intrusive or non-intrusive calibration.

Net Safetys Millennium Low Power Combustible and Toxic gas detectors are fast and accurateand an ideal solution for locations where continuous and reliable gas detection is essential and power supply is limited.

2721 Hopewell Place NE Calgary, Alberta, Canada T1Y 7J7 Houston | Abu Dhabi | Beijing | Singapore

1-866-FIREGAS (347-3427) ph. (403) 219-0688 | fx. (403) 219-0694 www.net-safety.com | nsmsales@net-safety.com

MILLENNIUM LOW POWER


Ultra-Efcient Combustible and Toxic Gas Detectors
MILLENNIUM SENSOR
RANGE OF DETECTION LINEARITY/REPEATABILITY RESPONSE TIME TEMPERATURE RANGE ENCLOSURE MATERIAL WARRANTY CERTIFICATIONS CSA and ANSI UL/ISA certified for hazardous locations. Class I, Division 1, Groups B, C and D. IEC Rating Ex d IIB+H2 T5. Performance certified to CSA C22.2 No. 152 ** High performance sensor is available, please consult facotyr.

BCR-0026-00-007 H2S TOXIC - ST1200 ELECTROCHEMICAL


0 to 10/20/50/100 ppm H2S 3% full scale / <5% full scale** <30 seconds to T90 -40C to +50C (-40F to +122F) [temperatures below -40C will slow response and increase readings] 2 Years CSA and ANSI UL/ISA certified for hazardous locations. Class I, Division 1, Groups C and D. IEC Rating Ex d IIB+H2 T6.

COMBUSTIBLE - SC1100 CATALYTIC BEAD


0 to100% LEL of most hydrocarbons and hydrogen* 3% LEL / 2% LEL <10 seconds to T50 | <30 seconds to T90 -40C to +85C (-40F to +185F)

Anodized / Powder coated aluminum (optional stainless steel)

* For other gases please consult the factory

MILLENNIUM LOW POWER TRANSMITTER/CONTROLLER


SPECIFICATION OPERATING VOLTAGE RANGE POWER CONSUMPTION MAX ST1200 SENSOR @ 50% SPAN POWER CONSUMPTION MAX SC1100 SENSOR @ 50% SPAN POWER CONSUMPTION MAX SC1100 SENSOR OPERATING TEMPERATURE AND HUMIDITY RANGE OUTPUT(S) ENCLOSURE MATERIAL WEIGHT ELECTRONICS WARRANTY ALPHA-NUMERIC DISPLAY UNIQUE FEATURES CERTIFICATIONS 12V 74 mA / 0.9 W 24V 50 mA / 1.25 W 12V 150 mA / 1.83 W 24V 80 mA / 2.02 W 12V 230 mA / 1.66 W 24V 120 mA / 1.87 W MLP-LP A VERSION
(4-20 mA ON / Display Dimmed)

MLP-LP ARS VERSION


(4-20 mA ON / Display Dimmed / Solid State Relays)

MLP-LP ARS VERSION


(4-20 mA OFF / Display Dimmed / Solid State Relays)

10.5 to 32.0 V dc 12V 80 mA / 1.04 W 24V 56 mA / 1.42 W 12V 150 mA / 1.72 W 24V 87 mA / 1.90 W 12V 240 mA / 1.68 W 24V 126 mA / 1.85 W 12V 48 mA / 0.78 W 24V 32 mA / 1.05 W 12V 125 mA / 1.41 W 24V 90 mA / 1.59 W 12V 215 mA / 1.38 W 24V 108 mA / 1.56 W

Operational -50C to +85C (-58F to +185F) / Certified -40C to +85C (-40F to +185F) 0 to 100% Relative humidity, non-condensing Analog 4-20 mA: Max. loop impedance of 800 Ohms at 32 V dc or 150 Ohms at 10.5 V dc. Isolated or non-isolated loop supply Solid State Relays: Low, High and Fault Form A contacts rated 2.5A at 60 V AC/DC Powder coated Copper Free Cast Aluminium (316 Stainless Steel Optional) 3.2 Kg (7.0 lbs) 3 Years Bright 8-digit LED scrolling type display - English, French and Spanish languages available Local Power Switch and Meter Test Jacks on faceplate for easy maintenance, Easy to read instructions for one-person, NON-INTRUSIVE calibration CSA and ANSI UL/ISA certified for hazardous locations. Class I, Division 1, Groups B, C and D. Temperature code T5. IEC Rating Ex d IIB+H2 T5 (Class I, Zone 1 Group IIB+H2 T5). Maximum Operating Ambient of 85C. Enclosure Type 4X. NOTE: Electronics only - CSA and ANSI UL/ISA certified for hazardous locations Class I, Division 2 Groups B, C and D.

ORDERING INFORMATION
MILLENNIUM PREMIUM MLP-A- | Analog output only COMBUSTIBLE SENSOR ELEMENT SC1100 | Poison Resistant Combustible Sensor 0-100% LEL ST1200-10/20/50/100 | Electrochemical Sensors for H2S ST1300-20/50/100 | Electrochemical Sensors for SO2 ST1500-10 | Electrochemical Sensor for CL2 ST1600-500 | Electrochemical Sensor for CO ST1700-100 | Electrochemical Sensor for NH3 OPTIONS / ACCESSORIES -SEP | Analog Sensor Separation Kit CCS-1 | Splash guard / Calibration cup MLP-FRO-0001 | Rotating Faceplate option

MLP-LP-AR- | Analog and Relay outputs

ORDER EXAMPLE: MLP-LP-A-SC1100-SEP


Millennium Low Power Premium Combustible Gas Detector with SC1100 Catalytic Bead Sensor, 4-20 mA Analog output only with an optional Sensor Separation Kit.

MLP-LP-ARS- | Analog and Solid State outputs

Changes are periodically made to the information within this document and incorporated without notice into subsequent revisions. Net Safety Monitoring Inc. assumes no responsibility for any errors that may be contained within this document. Please refer to manuals for complete specifications.

Distributed by:

2721 Hopewell Place NE, Calgary, Alberta, Canada T1Y 7J7 | 1-866-FIREGAS (347-3427) | ph. (403) 219-0688 | fx. (403) 219-0694 | www.net-safety.com

Anda mungkin juga menyukai