in Lighting Ranko Skansi, M.Sc.E.E.Ld. BALKANLIGHT 2008. BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. Structure BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. Societies Croatia HDR HZN HDR BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. Introduction HDR (Croatian Lighting Society Hrvatsko Drutvo za Rasvjetu) Public Act about Artificial Lighting HZN (Croatian Standard Institute Hrvatski zavod za norme) Norms and standards - HZN/TO 0-549 CEN/TC-50 (lighting columns and spigots) CEN/TC-169 (light and lighting) BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. Light in the context of productivity BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. Public Act about Artificial Lighting Preamble Main definitons Zones of Respect (Z0 to Z4) Section 2 Luminaire shielding Technical limits Source efficiency Mercury content Section 3 Lighting limits CIE norm Exceptions Billboards City lights Horticulture Glare Lighting beams Illumination of secured areas Interior lighting (suggestions) Section 4 Gear recommendations Section 5 Planning Project procedures Permissions needed for the correct lighting installations Section 6 Supervision Inspection Section 7 Penalties Final propositions Adaptation and reconstruction periods BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. LEX - Light pollution law Efficiency indeX 1 -2 1 Restriction of use 1 -2 1 Prohibition of emitting light above the horizontal 2 -4 2 Lighting for schools, hospitals, kindergartens 2 -4 3 Restriction of use 3 -5 5 Prohibition of emitting light above the horizontal 5 -5 8 Lighting for trading centres, gas stations, sport grounds, etc. 3 -5 3 Restriction of use 5 -5 5 Prohibition of emitting light above the horizontal 8 -5 8 Lighting for industrial premises (including ports and airports) 1 -5 1 Prohibition of sky-beamers and advertising with light beams 2 -10 3 Restricting the lighting with UV and blue colour 2 -10 12 Restriction of use 2 -1 2 Prohibition of accumulating lamps 16 -30 16 Prohibition of emitting light above the horizontal 20 -41 30 Street lighting (including railways) CRO MIN min MAX BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. LEX - Light pollution law Efficiency indeX 56 -140 100 Points total (maximum is 100 points or 100 %) (minimum is -140 points or 100%) 4 -2 4 Fines and efficiency of inspection -5 -5 2 Government support to NGO (evironment) for promotion, education, etc. 10 -5 10 What is the share of old lighting that needs to be replaced because of the Law 3 -4 3 Lighting can be mounted only based on the project which also includes pollution 2 -2 2 Can the lighting be mounted only by a registered person/company 1 -2 3 Prohibition of selling lamps which emit light above the horiz. for domestic use 2 -10 4 Security of accommodation spaces 0 -10 8 Lighting for cultural heritage (churches, castles, monuments) 1 -5 1 Restriction of use -5 -10 3 Lighting with 0 % ULOR -4 -15 4 Lighting for facades of business premises, schools, etc. 2 -5 3 Restrictions of power or luminosity 3 -10 5 Lighting with 0 % ULOR 5 -15 8 Lighting for billboards CRO MIN min MAX BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. LEX - Light pollution law Efficiency indeX C r o a t i a
5 6 S l o v e n i a
6 4 L o m b a r d i a
5 4 C a t a l o n i a
- 8 9 F l a n d r i a
- 1 2 1 U K
n u i s a n c e
- 1 2 7 -130 -120 -110 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. I nauguration procedure BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. I nauguration procedure BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. I nauguration procedure BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. I nauguration procedure BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. I nauguration procedure BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. I nauguration procedure BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. I nauguration procedure BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. I nauguration procedure BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. I nauguration procedure BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. Standards and Norms CEN/TC-50 (lighting columns and spigots) EN 40-1:1991, EN 40-2:2004, EN 40-3-1:2000, EN 40-3-2:2000, EN 40-3-3:2003, EN 40-4:2005, EN 40-4:2005/AC:2006, EN 40-5:2002, EN 40-6:2002, EN 40-7:2002 1 CEN/TC-169 (light and lighting) CEN/TR 13201-1:2004 CR 14380:2003 EN 12193:2007 EN 12464-1:2002 EN 12464-2:2007 EN 12665:2002 EN 13032-1:2004 EN 13032-1:2004/AC:2005 EN 13032-2:2004 EN 13032-2:2004/AC:2007 EN 13032-3:2007 EN 13201-2:2003 EN 13201-3:2003 EN 13201-3:2003/AC:2007 EN 13201-4:2003 EN 14255-1:2005 EN 14255-2:2005 EN 14255-4:2006 EN 15193:2007 EN 1837:1999 EN 1838:1999 EN 14255-3:2008 Croatian Standard Institute HZN/TO 0-549 BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. Standards and Norms Croatian Standard Institute HZN/TO 0-549 (CEN/TC-50) Lighting columns - Part 7: Requirements for fibre reinforced polymer composite lighting columns EN 40-7:2002 Lighting columns - Part 6: Requirements for aluminium lighting columns EN 40-6:2002 Lighting columns - Part 5: Requirements for steel lighting columns EN 40-5:2002 Lighting columns - Part 4: Requirements for reinforced and prestressed concrete lighting columns EN 40-4:2005/AC:2006 Lighting columns - Part 4: Requirements for reinforced and prestressed concrete lighting columns EN 40-4:2005 Lighting columns - Part 3-3: Design and verification - Verification by calculation EN 40-3-3:2003 Lighting columns - Part 3-2: Design and verification - Verification by testing EN 40-3-2:2000 Lighting columns - Part 3-1: Design and verification - Specification for characteristic loads EN 40-3-1:2000 Lighting columns - Part 2: General requirements and dimensions EN 40-2:2004 Lighting columns - Part 1: Definitions and terms EN 40-1:1991 BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. Standards and Norms Croatian Standard Institute HZN/TO 0-549 (CEN/TC 169) Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 3: Presentation of data for emergency lighting of work places EN 13032-3:2007 Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 2: Presentation of data for indoor and outdoor work places EN 13032-2:2004/AC:2007 Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 2: Presentation of data for indoor and outdoor work places EN 13032-2:2004 Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 1: Measurement and file format EN 13032-1:2004/AC:2005 Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 1: Measurement and file format EN 13032-1:2004 Light and lighting - Basic terms and criteria for specifying lighting requirements EN 12665:2002 Light and lighting - Lighting of work places - Part 2: Outdoor work places EN 12464-2:2007 Light and lighting - Lighting of work places - Part 1: Indoor work places EN 12464-1:2002 Light and lighting - Sports lighting EN 12193:2007 Lighting applications - Tunnel lighting CR 14380:2003 Road lighting - Part 1: Selection of lighting classes CEN/TR 13201-1:2004 BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. Standards and Norms Measurement and assessment of personal exposures to incoherent optical radiation - Part 3: UV- Radiation emitted by the sun EN 14255-3:2008 Lighting applications - Emergency EN 1838:1999 Safety of machinery - Integral lighting of machines EN 1837:1999 Energy performance of buildings - Energy requirements for lighting EN 15193:2007 Measurement and assessment of personal exposures to incoherent optical radiation - Part 4: Terminology and quantities used in UV-, visible and IR-exposure measurements EN 14255-4:2006 Measurement and assessment of personal exposures to incoherent optical radiation - Part 2: Visible and infrared radiation emitted by artificial sources in the workplace EN 14255-2:2005 Measurement and assessment of personal exposures to incoherent optical radiation - Part 1: Ultraviolet radiation emitted by artificial sources in the workplace EN 14255-1:2005 Road lighting - Part 4: Methods of measuring lighting performance EN 13201-4:2003 Road lighting - Part 3: Calculation of performance EN 13201-3:2003/AC:2007 Road lighting - Part 3: Calculation of performance EN 13201-3:2003 Road lighting - Part 2: Performance requirements EN 13201-2:2003 Croatian Standard Institute HZN/TO 0-549 (CEN/TC 169) BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. Conclusion Croatian efforts to adjust legislation according to EU HDR Public Act about Artificial Lighting Part of Public Act about Ecology Corelated to the EU legislation and CIE norms Compatible to the Kyoto protocol and Declaration form the Venice Complicated Inauguration process Legislation vs. Standardization and Normization Croatian Standard Institute HZN/TO 0-549 CEN/TC-50 CENT/TC-169 Associations HDR (Croatian Lighting Society Hrvatsko Drutvo za Rasvjetu) CIE National representative BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. HDR Croatian Lighting Society Hrvatsko drutvo za rasvjetu (HDR) Headquarters: Preradovieva 40, 10000 HR-Zagreb Mobile (president: Mrs. Diana Gali): +385 (0)98 409 989 Mobile (secretary: Ranko Skansi, M.Sc.E.E.Ld.: +385 (0)99 217 3522 Fax: +385 (0)1 6389 139 Web: www.hdr-cie.hr E-mail: hdr@hdr-cie.hr BALKANLIGHT 2008 - Ranko Skansi, M.Sc.E.E.Ld. Thank You Ranko Skansi, M.Sc.E.E.Ld. Executive manager Intra lighting d.o.o. Moslavaka 28, AZMA, CROATIA Intra studio Ul. Grada Vukovara 269 D, VMD Building, ZAGREB, CROATIA ranko.skansi@intra-lighting.com http://www.intra-lighting.com Mobile: +385 99 2173 522