Eaton's Markets
Literature Library
Our Company
Contact Us Contact
E-mail Us Call Us
Products by Name
Market Solutions
Videos
Video Library Features
Applications
Documentation
Purchase
Resources
Literature Library Calculators
Features No Priming Required Stainless Steel Internal Parts Internal Parts Removed w ith Cover No Loss of Line Pressure Choice of Inlet/Outlet Configurations Options Heater for Low Temperature Applications Eaton drain traps have been an industry standard since 1894. They efficiently handle, w ithout loss of line pressure, the draining of condensate removed from air or gas lines by separators of the condensate w hich accumulates in storage tanks or at drip points. These traps are capable of removing up to 2800 pounds of condensate per hour and w ork w ith pressure differentials from 5 psi up to 250 psi. Model 90-AC and 95-AC Float Drain Trap Available in cast iron or cast stainless steel for 0 to 500 psi service. Loss of air or gas is prevented by a positive w ater seal. They have a straight-through design. Internal parts, including valve and seat, are corrosion-resistant, non-magnetic stainless steel. All w orking parts are attached to the base for easy removal and inspection. A side inlet/outlet configuration is available for iron, carbon steel and stainless steel traps. Model 230-AC Available in cast iron for 0 to 125 psi service. Ideal for use w here gummy emulsions or cylinder lubricants make other traps inoperative. They feature a vertical inlet, dow nflow discharge design. Ample float pow er and large outw ard-opening discharge valve prevent loss of pressure. Internal parts are stainless steel, including non-magnetic valve and seat. Working parts are attached to the cover for easy removal w ithout disconnecting the trap from the line. No priming is required. For low temperature applications a heater is available as an option. Model 350-AC THREE TRAPS IN ONE is the basic principle of these ball float traps. Three valves open and close progressively as condensate volume varies. As float chamber w ater level rises, the float lies deep in the w ater until its buoyancy overcomes the opposing line pressure and snaps the valve w ide open. When closing, as each valve approaches its seat, the line pressure snaps it tightly closed. These traps have cast iron bodies, and stainless or copper internal parts. A by-pass thermostat is standard.
http://www.eaton.com/Eaton/ProductsServices/Filtration/GasLiquidSeparators/SeparatorDrainTraps/index.htm
1/2
1/31/2014
Steam Turbines Intercooler Equipment Aftercooler Equipment Gas Well Heads Deep Well Heads Oil Extraction Chemical Processing Scrubbing Systems Evaporator Glycol Dehydration Sulfer Condenser Mist Elimination Heat Exchangers Reactors Landfill/Waste Gas
Brochures
Technical Information
Drawings
North America - HQ
44 Apple Street Tinton Falls, NJ 07724 Toll Free: (800) 656-3344 (NORTH AMERICA ONLY) Voice: (732) 212-4700
Europe/Africa/Middle East
Auf der Heide 2 53947 Nettersheim, Germany Voice: +49 2486 809-0
China
No. 7, Lane 280, Linhong Road Changning District, 200335 Shanghai, P.R. China Voice: +86-21-5200-0099
Begerow Product Line An den Nahew iesen 24 55450 Langenlonsheim, Germany Voice: +49 6704 204-0 Internorm en Product Line Friedenstrae 41 D-68804 Altussheim, Germany Voice: +49 6205 2094-0
Singapore
Brazil
Av. Julia Gaioli, 474Bonsucesso 07251-500 - Guarulhos, Brazil Voice: +55 (11) 2465-8822
Products on this site may not be available in all regions. Please contact your local Eaton office to determine availability.
http://www.eaton.com/Eaton/ProductsServices/Filtration/GasLiquidSeparators/SeparatorDrainTraps/index.htm
2/2