Interface Your Voice Paging System with Virtually Any Telecom or IP Phone System
Vikings FXI-1 universal paging interface allows you to provide paging from virtually any type of phone system instead of from a microphone. You can also provide background music and electronic night bell over the audio system. The FXI-1 provides 26V talk battery for interfacing with an FXO or unused analog line input/trunk port. With the flip of a switch, the unit can connect to a FXS or PABX station ring trip port. No power supply is required in this mode. In the event that it must be connected to a dry 600 ohm paging port, the built-in voice activation (VOX) is in control. This configuration is useful when interfacing with systems that do not provide a paging contact closure, such as Panasonic, South Western Bell, Intertel, etc. In all modes the FXI-1 provides normally open or normally closed relay contacts to activate the central paging amplifier equipment or connect to an external background music source. After paging, the FXI-1 auto disconnects on CPC, busy signal, silence or default disconnect timer. An electronic night bell over paging feature can be activated from a momentary phone system contact closure (FXO and page port mode only).

Features
Select: FXO (loop start), FXS (ring trip) or paging port (VOX relay) interface mode No power supply required in FXS interface mode Up to 6 units can be powered from one adapter in the FXO or VOX mode 26V DC talk battery for interfacing with FXO or unused phone system line input/trunk port Floating 600 ohm paging output with volume control Normally open or closed relay for external paging amp activation or interfacing the paging amp with an external background music source 800 Hz pre-page page tone (on/off) Compatible with 24 to 48 volt FXS operation Calling party control (CPC) detection for immediate disconnect Busy signal detect disconnect 2.5 second VOX silence disconnect timer Programmable VOX trigger sensitivity Disconnect timer: 16, 36, 60 seconds or disabled Screw terminal block connections Wall mount housing: (2) #6x3/4 panhead screws included

Applications
Integrate your paging system with virtually any POTS, Centrex, Digital or IP phone system Suppress background music during paging Provides contact closure to activate paging system if not provided by the phone system Add pre-page tone to your paging system

h t t p : / / w w w. v i k i n g e l e c t r o n i c s . c o m

Specifications
Power: 12-24V DC @ 100mA, 120V AC/12V DC @ 500mA, UL listed adapter included (not required in FXS mode) Dimensions: 111mm x 76mm x 36mm (4.38 x 2.97 x 1.38) Shipping Weight: .48 kg (1.06 lbs) Environmental: 0C to 32C (32F to 90F) with 5% to 95% noncondensing humidity Relay Contacts: 30V DC@1A, 110V DC@0.3A, 125V AC@0.5A VOX Minimum Audio Signal to Activate Relay: -28dbm minimum / -25dbm minimum @ 1KHz with VOX sensitivity switch at normal / lower positions VOX Time Out Disconnect: 2.5 seconds Default Time Out Disconnect: 16, 36, 60 seconds or disabled Talk Battery: 26V DC

Wa r r a n t y
IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT PLEASE CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666
Our Technical Support Department is available for assistance Monday 8am - 4pm and Tuesday to Friday 8am - 5pm central standard time. So that we can give you better service, before you call please: 1. Know the model number, the serial number and what software version you have (see serial label). 2. Have your Technical Practice in front of you. 3. It is best if you are on site.

RETURNING PRODUCT FOR REPAIR


The following procedure is for equipment that needs repair: 1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc. 2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to: Viking Electronics, 1531 Industrial Street, Hudson, WI 54016 3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a P.O. Box. 4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned.

RETURNING PRODUCT FOR EXCHANGE


The following procedure is for equipment that has failed out-of-box (within 10 days of purchase): 1. Customer must contact Vikings Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis. 2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return Authorization (R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue. 3. After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the product over the counter at no charge. The distributor will then return the product to Viking using the same R.A. number. 4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge.

LIMITED WARRANTY
Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of one year from the date of purchase from any authorized Viking distributor or 18 months from the date manufactured, which ever is greater. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number. This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the purchaser or others. This warranty does not cover non-EWP products that have been exposed to wet or corrosive environments. NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER, OR ANY OTHER PARTY, FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER. EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT VIKING'S OPTION, REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED. IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH.

FCC REQUIREMENTS
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the side of this equipment is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company. The REN is used to determine the number of devices that may be connected to a telephone line. Excessive REN's on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of the REN's should not exceed five (5.0) To be certain of the number of devices that may be connected to a line, as determined by the total REN's, contact the local telephone company. For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US:AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label. The plug used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of this FXI-1 does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer. If the FXI-1 causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications to maintain uninterrupted service. If trouble is experienced with the FXI-1, for repair or warranty information, please contact: Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016 (715) 386-8666 If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. Connection to Party Line Service is subject to State Tariffs. Contact the state public utility commission, public service commission or corporation commission for information. WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO EMERGENCY NUMBERS: Remain on the line and briefly explain to the dispatcher the reason for the call. Perform such activities in the off-peak hours, such as early morning or late evenings. It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected. This is to avoid damaging the equipment caused by local lightning strikes and other electrical surges.

PART 15 LIMITATIONS
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Installation
!
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.

A. Adding Background Music


If background music is not available on the central paging amplifier, the FXI-1 can be wired as shown below. This application works in all modes and the music is suppressed during paging.
Background Music Source (not included)
10 9 8 7 6

Terminal Detail
10 9 8 7 6 5 N.C. COM Relay Contacts N.O. 600 Audio Output FXS (ring trip), FXO (loop start) or VOX (page port) input Night Bell Ground Power

Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

Internal View of the FXI-1

B. Recommended Wiring to Eliminate Idle Noise and Clicks


If the contacts are not used to activate the external paging amplifier, wire as shown to eliminate idle noise and clicks.

RoHS

Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

Internal View of the FXI-1

C. Up to 6 FXI-1 Units Share 1 Power Supply - FXO or VOX (Powered) Mode


Up to 6 FXI-1 units can be wired as shown below and share a single 12V 500mA adapter. This is useful in the FXO or VOX (powered) mode.

RoHS

Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx

2 1

Red power LED must be ON Power Input adapter included

Internal View of the FXI-1

VIKING

Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx

VIKING

VIKING

Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx

To Paging Amplifier: Floating 600 ohm output. Connect to input of paging amplifier.

RoHS

Blue LED indicates that the FXI-1 is active (paging) in all modes.

4 3 2 1

(2) #6x3/4 panhead screws (included)

9 8 7 6

To Paging Amplifier: Floating 600 ohm output. Connect to input of paging amplifier.

Blue LED indicates that the FXI-1 is active (paging) in all modes.

(2) #6x3/4 panhead screws (included)

Internal View of the FXI-1


To Additional FXI-1 Units

D. FXS (Ring Trip) Mode (Do Not Use the Included Power Supply)

Internal View of the FXI-1


10 9 8 7 6 5 4 N.C. COM N.O.

RoHS

Relay Contacts 600 Ohm Audio Output to Paging Amplifier FXS (Ringing Station) Input FXS

Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

Red power LED must be OFF

E. FXO (Loop Start) Mode - Power Required

Internal View of the FXI-1


10 9 8 7 6 5 4 N.C. COM N.O.

RoHS

Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx

Red power LED must be ON

VIKING

VIKING

Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx

Talk Battery Switch Note: DIP Switch 5 must be OFF.

Relay Contacts 600 Ohm Audio Output to Paging Amplifier FXO (Unused Trunk) Input

FXO Talk Battery Switch Note: DIP Switch 5 must be OFF.

F. VOX (Page Port) Mode - Power Required

Internal View of the FXI-1


10 9 8 7 6 5 4 N.C. COM N.O.

RoHS

Relay Contacts 600 Ohm Audio Output to Paging Amplifier 600 Ohm Page Port In FXS

Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

Red power LED must be ON

G. Night Bell Over Page - FXO or VOX Modes Only, Power Required

Internal View of the FXI-1


RoHS

Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx

Red power LED must be ON

VIKING

VIKING

Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx

Talk Battery Switch Notes: DIP Switch 5 must be ON. There is no pre-page beep in this mode.

3 2

Phone System N.O. Ring Contact Closure

Note: DIP Switch 4 must be ON.

VIKING

VIKING

VIKING

H. Telephone Line Powered Ring Trip Paging and Loud Ringing

VIKING

6
RoHS

Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx


RoHS
Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx

Incoming Ringing Line

2. Paging as Priority

1. Loud Ringing as Priority

Internal View of the K-600F

Internal View of the K-600F

Incoming Ringing Line


Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

OR

OR
To Paging Amplifier Input (600 Ohm)
4 3
Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx
RoHS
Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx

To Paging Amplifier Input (600 Ohm)

Internal View of the FXI-1


10 9 8 7 6 5 4

Internal View of the FXI-1

Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

10 9 8
RoHS

Talk Battery Switch

Talk Battery Switch

FXS

FXS
7 6 5 4

To FXS Paging Line Input

To FXS Paging Line Input

Programming
A. DIP Switch Programming
Switch 1 OFF ON OFF ON Switch 3 3 4 4 5 5 Switch 2 OFF OFF ON ON Position ON OFF ON OFF ON OFF Description 16 second default timer, busy detect off 36 second default timer, busy detect on 60 second default timer, busy detect on Default timer disabled, busy detect on Description Lower VOX sensitivity Normal VOX sensitivity Pre-page and night bell tone on Pre-page and night bell tone off VOX (600 ohm page port) mode FXS (ring trip) or FXO (loop start) mode
Internal View of the FXI-1 Master Volume Control

ON

OFF
5

ON

Note: DIP Switches shown in factory default settings.

B. Talk Battery Switch (FXO vs. FXS)


1. FXO
An FXO port is an analog input RJ11 port just like a POTS trunk input on a PABX or key system. An FXO port receives talk battery and ring voltage. In the FXO mode, the FXI-1 provides 26V talk battery to connect to an FXO port or plain analog phone.

2. FXS
An FXS port is an analog output RJ11 port just like a station port on a phone system or PABX extension. It provides talk battery, dial tone and ring voltage. In the FXS mode, the FXI-1 is triggered by ring voltage to seize the line, it is then powered by the talk battery being provided.

Operation
A. FXS (Ring Trip) Mode
In this mode, the unit is powered by the ringing line and answers after 1 second, activates the relay contacts and provides a prepage beep if enabled (S1-4 on). If more than 2.5 seconds of silence, a busy tone (default timer >16 seconds), or a CPC are detected, or the default timer expires, the unit releases the relay and drops the line.

B. FXO (Loop Start) Mode


In this mode, the unit waits until loop is detected, then activates the relay contacts and provides a pre-page beep if enabled (S1-4 on). If more than 2.5 seconds of silence or a busy tone (default timer > 16 seconds) is detected, or the default timer expires, the unit releases the relay and provides a 2 second CPC.

C. VOX (Page Port) Mode


In this mode, the unit waits until audio is detected, then activates the relay contacts. If more than 2.5 seconds of silence or a busy tone (default timer > 16 seconds) is detected, or the default timer expires, the unit releases the relay. There is no pre-page beep in this mode.

D. Night Bell Over Page


If the unit is installed in FXO or VOX mode and not currently paging or providing a CPC, a momentary closure on the Night Bell input for 50mS or more will trigger a 1 second pause followed by relay activation, a 1.5 second warble tone, and relay release. A continuous closure on the night bell input causes the 1 second pause, 1.5 second warble tone cycle to repeat until the closure is removed.

Tr o u b l e s h o o t i n g
Some VoIP products provide a low power ring signal designed for electronic phones that adaptor-powered equipment can detect easily, but line-powered equipment has trouble using to activate a relay. In this case it is recommended to use FXO (Loop Start) mode if possible by changing to an unused trunk input, otherwise connect the equipment as shown in the special FXS Power Assist (Ring Trip) Mode. In this installation, a short page may be heard when the unit is powered on, but will then function as normal.

FXS Power Assist (Ring Trip) Mode - Power Required


Internal View of the FXI-1
10 9 8 7 6 5 4 N.C. COM N.O.

RoHS

Relay Contacts 600 Ohm Audio Output to Paging Amplifier FXS (Ringing Station) Input FXS

Viking Electronics, Inc. (715) 386-8861 1531 Industrial St., Hudson, WI 54016 www.vikingelectronics.com DOD#

Red power LED must be ON

Product Support Line...715.386.8666


DOD# 494 Printed in the U.S.A.

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

VIKING

Model: xxxxxxxxx S/N: XXXXXXXX DEV: P/N: xxxxxxxx

Talk Battery Switch Note: DIP Switch 5 must be OFF.

Fax Back Line...715.386.4345


ZF303020 Rev A

Anda mungkin juga menyukai