C

1. DO NOT SCALE FROM DRAWNGS. USE WRTTEN DMENSONS ONLY.


2. BULDER TO CHECK & VERFY ALL DMENSONS & LEVELS PROR TO
COMMENCEMENT OF WORK.
3. T S THE OWNERS RESPONSBLTY TO ENSURE THAT THE ENGNEER
HAS NVESTGATED SUBSOL CONDTONS & DESGNED ALL
STRUCTURAL ELEMENTS TO SUT.
4. THE DESGN & DETALS CONTANED ON THS DRAWNG S SUPPLED N
CONFDENCE & S NOT TO BE USED FOR ANY OTHER PURPOSE,
EXCEPT THATAUTHORSED BY DEANGELS TAYLORAND ASSOCATES
Drawing No.
WD08
Amend't
E
No. of sheets
Job No.
10099
Drawn:
B.T
ScaIe:
As shown @A1
Project:
Dwg Name:
Address:
Nominated Architect:
CAD File: Z:\2010\10099.Liverpool Council.Rose St\3.Design\3.3 WD\10099.WD.(D).Rose St.Liv Council.pln
I: 1 2 01 1011 f: 1 2 821 2213 w: www.cI c.neI .cu
8 8 L c I h u r : I : I r e e I | i v e r p c c | n : w 2 1 7 0 c u : I r c | i c
pc Lcx 8 | i ver pcc| Lc n: w 1871 e: ccmi n@ cI c.neI .cu
Issue Amendment
P1
Drwn Date Chk'd
07.06.2011 AB BA PRELMNARY SSUE
CIient: Project North:
LIVERPOOL
CITY
COUNCIL
STEPHEN TAYLOR.....................................................................................
NSWArchitects Registration Board No. 7414 8 of 13
or ch| t ect ur e | nt er | or des| gn ur bon des | gn
COPYRGHT 2010 - DE ANGELS TAYLOR + ASSOCATES PTY LTD
ROSE STREET DEPOT - FITOUT CONTRACT
ROSE STREET LIVERPOOL NSW 2170
SECTIONS
14.02.12
Date:
P2 30.06.2011 AB BA PRELMNARY SSUE
A 11.08.2011 AB BA CONSTRUCTON SSUE
C 14.02.12 BT ST SSUED FOR TENDER
D 24.02.12 BT ST SSUED FOR TENDER
E 27.02.12 BT ST AMENDED FOR TENDER
d e o n g e I | s t o y I o r + o s s o c | o t e s
1 0 0
9 0 0
CELNG LEVEL - 22.72 CELNG LEVEL - 22.72
SERVER CELNG LEVEL - 22.62
CELNG LEVEL - 22.72 CELNG LEVEL - 22.72 CELNG LEVEL - 22.72
TOP OF WALL - 23.62
CELNG LEVEL - 22.42 CELNG LEVEL - 22.42
3 0 0
Shadow Angle Trim
Shadow Angle Trim
AFFL + 2600mm. Proposed suspended ceiling hung from
existing concrete slab with 1 layer of 13 mm plasterboard.
P50 shadow mould to all Wall / Ceiling junctions.
Shadow Angle Trim
13mm Plasterboard
100mm Metal Stud
Al. angle trim
FL + 2700mm. Proposed suspended ceiling hung from
existing roof structure with acoustic lay in ceiling tiles (1200
x 600) and R1.8 insulation layed directly on top of ceiling
lining. P50 shadow mould to all hebel block & brick wall /
ceiling junctions (angle trim to 92mm steel stud parti. walls).
FL + 2700mm. Proposed suspended ceiling hung from
existing roof structure with acoustic lay in ceiling tiles (1200
x 600) and R1.8 insulation layed directly on top of ceiling
lining. Angle trim 92mm steel stud parti. walls (P50 shadow
mould to all hebel block & brick wall / ceiling junctions).
Water resistant 10mm FC Panel
92mm Metal Stud
FL + 2400mm. Proposed suspended ceiling hung from
existing roof structure with 2 layers of water resistant
plasterboard. Angle trim 92mm steel stud parti. walls (P50
shadow mould to all hebel block & brick wall / ceiling
junctions).
Ceramic tile as specified
16mm furring channel.
Position indicative only
Ceramic tile as specified
Exist. concrete block wall
Existing re-inforced concrete slab.
13mm Plasterboard
FL + 2700mm. Proposed suspended ceiling hung from
existing roof structure with acoustic lay in ceiling tiles (1200
x 600) and R2 insulation layed directly on top of ceiling
lining. P50 shadow mould to all hebel block & brick wall /
ceiling junctions (angle trim to 92mm steel stud parti. walls).
Shadow Angle Trim
100mm Metal Stud
2 X 13mm Plasterboard
16mm furring channel.
Position indicative only
2 X 13mm Plasterboard
2 X 13mm Wet area Plasterboard
2 X 13mm Wet area Plasterboard
100mm Metal Stud
2 X 13mm Plasterboard
16mm furring channel.
Position indicative only
GeneraI 92 mm metaI stud
frame waIIs within office area
GeneraI 92 mm metaI
stud frame waIIs within
amenities area
Nom. 90mm steel stud framed wall, 3.6m high,c/w insulation & 2 layers
of 13mm plasterboard lining both sides of framing, equal to Boral Wall Systems S2626.
(Wet area plasterboard to internal of wet areas) set ready for selected paint finish.
OFFCE
AMENTES
13 92 13
WaII between Office & Amenities
Amenities
FL + 2400mm. Proposed suspended ceiling hung from
existing roof structure with 2 layers of water resistant
plasterboard. P50 shadow mould to all hebel block &
brick wall / ceiling junctions (angle trim to 92mm steel
stud parti. walls).
WaII encasing IT Server
room
Office Server Office
2 , 7 0 0
GROUND FLOOR LEVEL - RL 20.02
CELNG LEVEL - 22.72
GROUND FLOOR LEVEL - RL 16.23
2 , 3 5 0
Existing struct. column beyond
New colorbond fascia, gutters
& downpipes
Existing timber roof truss
New entrance portal. Rendered brick
walls, timber framed roof, to eng's
detail, with ACM cladding. Refer to
spec.
Proposed whirlybirds.
Raked plasterboard lining to new light well
Lunch Room Open PIan Office Entry
Verandah
3 deg.
V O
S
Note: existing roof sagging to be
repaired as per engineers instructions
Proposed al. extruded
framed window.Refer to
schedule for details.
Proposed timber framed awning
with translucent roof sheeting over.
Refer to specification for details.
New colorbond roof sheeting fixed to
existing timber truss roof structure
New 270 brick cavity infill wall. Provide min. R 2.1
insulation. Refer to Section J Report. Facebrick
finish to match existing.
Steel 90mm double stud , FC external.
Plasterboard internal.
New suspended ceiling with a min. of
R1.8 insulation. Refer to Reflected
Ceiling Plan & specification for details.
DAR Finish to exposed existing
timber roof trusses and columns
Provide 13mm plasterboard
lining on furring channels to all
visable faces of brickwork in the
lunch room, paint finish Existing concrete slab
Provide 13mm plasterboard lining on furring
channels to all visable faces of brickwork,
paint finish.
Existing 270 cavity face brick wall.
Provide min. R 2.1 insulation.
Refer to Section J Report.
Proposed skylights to existing roof
2 , 7 0 0
GROUND FLOOR LEVEL - RL 20.02
CELNG LEVEL - 22.72
Existing internal wall 230
New colorbond fascia,
gutters & downpipes.
Existing roof truss
Alum. vertical louvres attatched to galv. steel
frame to eng. details. With alucobond clad
steel frame awning overhead to eng. details.
Outline of existing window opeining.
Refer to demolition plan for details.
Proposed window. Refer to window
schedule for details.
New suspended ceiling with a
min. of R1.8 insulation. Refer
to Reflected Ceiling Plan &
specification for details.
Remove ex. door, brick up
opening, all finishes to match
existing adjoining surfaces
Walls between amenities &
Office/Corridor area to have a min. of
R0.9 insulation. Refer to Section J Report
Lunch Room
FemaIe ToiIets/
Changerooms
Office 3 Office 4
Note: existing roof sagging to be
repaired as per engineers instructions
New bathroom fixtures
Proposed al. extruded
door frame, c/w timber
solid core door, paint
finish. Refer to
schedule for details.
Proposed cavity face brick wall.Plasterboard lining
on furring channels, paint finish.
Proposed al. extruded framed
glazed door.Refer to schedule
for details.
Proposed al. extruded framed windows & glazed
door.Refer to schedule for details.
Proposed al. extruded framed windows & glazed
door.Refer to schedule for details.
4
WD10
New colorbond roof sheeting fixed to
existing timber truss roof structure
Existing face brick structural column. Plasterboard
lining on furring channels, paint finish.
Nom. 90mm Steel stud wall above windows, with set fc
lining external & plasterboard lining internal. Paint finish
Opaque film to be
fixed internaly
to exist. window panes
Existing 270 cavity face brick wall.
Provide min. R 2.1 insulation.
Refer to Section J Report.
2 , 7 0 0
GROUND FLOOR LEVEL - RL 20.02
CELNG LEVEL - 22.72
Existing timber roof truss
New colorbond fascia,
gutters & downpipes New colorbond fascia, gutters
& downpipes
New entrance portal. Face brick walls,
timber framed roof, to eng's detail, with
ACM cladding. Refer to spec.
Proposed whirlybirds.
Proposed Skylights.
New suspended ceiling with a min. of
R1.8 insulation. Refer to Reflected Ceiling
Plan & specification for details.
Walls between amenities &
Office/Corridor area to have a min. of
R0.9 insulation. Refer to Section J Report
FemaIe ToiIets MaIe ToiIets Change
Room
Open PIan Office Verandah Change
Room
http://www.fatsickandnearlydead.com/
Note: existing roof sagging to be
repaired as per engineers instructions
Proposed timber framed awning
with translucent roof sheeting over
existing pavement.
Refer to specification for details.
ndicative location of proposed A/C units
New changeroom lockers
New vanity fixtures
Existing 270 cavity face brick
wall.Provide min. R 2.1 insulation.
Refer to Section J Report.
Nom. 90mm steel stud framed wall, 3.6m high,c/w insulation & 2
layers of 13mm plasterboard lining both sides of framing, equal to
Boral Wall Systems S2626.(Wet area plasterboard to internal of
wet areas) set ready for selected paint finish.
New shower fixtures
New urinal pans
& wc fixtures
New urinal pans
& trough fixtures New changeroom lockers
Proposed al. extruded
door frame, c/w timber
solid core door, paint
finish. Refer to
schedule for details.
New colorbond roof sheeting fixed to
existing timber truss roof structure
2 , 7 0 0
GROUND FLOOR LEVEL - RL 20.02
CELNG LEVEL - 22.72
Existing timber roof truss
New colorbond fascia, gutters
& downpipes
New entrance portal. Face brick walls,
timber framed roof, to eng's detail, with
ACM cladding. Refer to spec.
New suspended ceiling with a min. of
R1.8 insulation. Refer to Reflected
Ceiling Plan & specification for details.
D01
1
WD09
Aluminium framed
door and glazing.
Refer to schedule for
details.
Existing 270 cavity
face brick wall.Provide min.
R 2.1 insulation. Refer to
Section J Report.
Existing 270 cavity
rendered brick wall.Provide min. R
2.1 insulation. Refer to Section J
Report.
Outline of existing opening,
refer to demolition plan.
New colorbond roof sheeting fixed to
existing timber truss roof structure
5
WALL / CElLllNG JUNCTlON DETAlLS
1:5
1
S/01 Section 1
1:100
2
S/02 Section 2
1:100
3
S/03 Section 3
1:100
4
S/04 Section 4
1:100

Anda mungkin juga menyukai