The offset pivot design ran cooler in all cases tested, as much as
20C (68F) lower than the center pivot design. The benefit
improved with speed and load.
Offset pivot power losses were the same to slightly higher than
the center pivot pad.
Effects of Reduced Flow
The LBP orientation in most cases ran cooler than LOP, but not
as cool as expected, which is also attributed to hot oil carryover.