Check points for GA drawing with Design Data & Nozzle Schedule
S.No. 1(a). (b) (c) (d) (e) (f) (g) (h) (i) (j) Description Design Data Design Code --Edition & addenda checked Design Pressure (Int./Ext.) MAWP in case of U1 jobs Design Temperature MAWP based on actual thickness(Applicable as per client requirement) Corrosion Allowance(Internal/External) Radiography PWHT Weights-Fabricated Empty/Erection Operating Hydrotest-Shop Hydrotest-Site Service Insulation/Fire Proofing Pressure Drop(If applicable) Loadings as per UG-22 MDMT Impact test requirement checked
Shell/D'end material checked as per UCS/UHA Nozzle Neck MOC checked Nozzle forging material checked Pressure Bolting material as per UCS/UHA checked Gasket MOC checked For standard flanges as per ASME B 16.5 bolting MOC & Gasket MOC compatible as per rating 8 Shell thickness checked ----For all applicable loadings 9 D'end thickness checked ----For all applicable loadings 10 Nozzle Design checked 11 Standard Flanges rating checked as per Design pressure/MAWP & temperature 12 Whether standard flanges are to be checked for equivalent pressure for process nozzles 13 Fillet sizes(if applicable) checked 14 Flange gasket face finish checked 15 Radiography requirement for Long seam/Circ Seam checked 16 Flange Design checked as per equivalent pressure(If applicable) 17 Special service requirement(Hydrogen/Lethal if applicable) checked 18 Foundation loading data checked 19 Local load for process nozzles mentioned along with loading direction & Location checked 20 Support design i.e. no.,size,BCD for foundation bolt & base block,skirt/saddle thickness Checked 21 Code stamp vessel. Name plate shall be on Vessel only. Name on Skirt not accepted For, Part vessel. Code Stamping or Name plate shall be provide for each part 22 Check for Nut fouling with SRN Nozzle Forgin. 23 Check for feasibility of Stud insertion for flange while top elbow is nearer to flange Above mentioned are the min. check points. All other client/code/statutory
CLIENT :
YAMUNA NAGAR
PAGE: REV.
Above mentioned are the min. check points. All other client/code/statutory requirements are to be complied with. Designer Head Design
1 0
CLIENT :
YAMUNA NAGAR
PAGE: REV.
1 0
Above mentioned are the min. check points. All other requirements are to be complied with. Designer Head Design
CLIENT :
YAMUNA NAGAR
PAGE: REV.
Above mentioned are the min. check points. All other client/code/statutory requirements are to be complied with. Designer Head Design