in
Tank Level & Flow Instrumentation Products sales@sigmainstruments.co.in
Level Switch
Side Mounted Level Switch 20-21
External Cage Level Switch 22-23
Top Mounted Level Switch 24-25
Level Switch (REED) Type 26-27
Conductivity Level Switch 28-29
Pneumatic Level Switch 30
Transmitter 31
Allied Products
Condensate Pot 36-37
Manifolds 38
Instrumentation Fittings 39
Needle Valve 40
Custom Products 41
Level Switch-Cable Float 42
Disclaimer: All the products mentioned in this catalogue are our standard
design. If the standard products do not meet your requirements, we
can modify them to meet your specifications and would appreciate the
opportunity of making suggestions to cover your application, based
on engineering principles. SIGMA reserves the right to modify
specification / design from time to time, which is deemed suitable
for the product without prior intimation.
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
THE SYSTEM: The Flat Gauges are inevitable means for process fluid measurement when it comes to severity of
conditions. The medium to be measured is made available for direct measurement outside the vessel without any
special preparations and provides on line monitoring. The principle of liquid maintaining the same level makes this
system very precise and reliable. The fluid attains its level in the chamber of the level gauge as that of the vessel and is
viewed through a glass window. SIGMA Gauge Valves form a major component of the flat glass gauges. Two gauge
valves at the ends of the gauge chamber are connected to the tank. Under normal operations, the valves are kept
wide open causing the pressure to equalize in the system thus permitting the liquid to seek its true level for observation
along the visible length. SIGMA offers Reflex and Transparent type Flat Level Gauges as required by the industry.
Sigma Advant-edge
ilable
Ava
IBR Approved
Flat Glass Gauge
TUV India Private Ltd.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
The Reflex Level Gauge consists of a chamber designed to have one SIGMA Reflex Level Gauge is recommended for clean, colorless and
or more front windows i.e on one side of the chamber. Each window non viscous services. Sticky fluids tend to coat the glass and result in
consists of a special glass called reflex glass that is cushioned wrong readings, Erroneous indications will also occur if fluid is near
between cover plates and chamber . The reflex glasses are provided saturation conditions or when the boiling or condensation in gauge
with prismatic grooves on the side in contact with the medium. As a glass affects the refraction of light through the prisms.
result of the difference in refractive index, light rays entering the gauge
from outside are reflected or absorbed. The light rays entering the SIGMA Transparent Level Gauge is recommended for colored or
steam or gas space strikes the grooves face at an angle of 450C, viscous fluids, interface detection and direct observation of the
thereby being refracted into the opposite groove face from which it is physical state. A source of light can be provided by a illuminator which
reflected back to the direction of observation. The steam or gas space is located at the back of the gauges, enabling readings of the liquid /
appears silver while and the liquid space appears black. This steam interface. Quick closing of the gauge valve feature allows the
eliminates any possibility of error in reading the liquid level The Reflex needle to plug the seat very quickly and seal off the process.
Level Gauge does not require an illuminator.
Gauge Construction
NUT
SPRING
WASHER
COVER PLATE
CUSHION GASKET
GLASS
SEAL GASKET
MAIN CHAMBER
U BOLT STUD
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
SIGMA Welding Pad Gages are used where conventional gage and valve construction is impractical because of solid matter
in suspension, under conditions where the thermal error caused by piping to a gage glass cannot be tolerated or where
space requirements suggest their use. Included are applications involving high vibration, highly viscous liquids or liquids
with considerable amounts of solids. SIGMA offers end users a flat or radius weld pad gage in varying lengths and
configurations. It is possible to monitor color, clarity and level of a gas / liquid interface. Because there are no nipples through
which the process liquid enters the gage, clogging potential is eliminated.
SIGMA Welding Pad Gages are made in both Reflex and Transparent Types. Reflex gages are used where liquid reading only
is required. Transparent gages are usualy used where installation is made on each side of the vessel to give see-through
visibility.
The System
SIGMA weld pad gages comprise of six basic components. Each component may
vary slightly, depending on the desired physical and mechanical properties for the
gage. refer picture:
2. Gasket - seal the gap and prevent leakage between the chamber and the glass.
Gaskets are available in a variety of materials for compatibility with the media in
the gage.
3. Cushion - acts as a protective buffer between the glass and the cover. For proper
sealing, cushions must be as hard or harder than the gasket material.
4. Cover - protects the glass assembly from external hits and provides a flat, rigid
surface that is used to evenly compress the gage assembly.
5. Bolting - compresses the components between the covers & weld pad chamber.
Mica Shield - (Optional on transparent gages) used to prevent the process media
from contacting the glass.
Load Consideration: Whenever it is necessary to slot the tank because of the nature
of the liquid or there is need to observe the color or interface of the liquid, the following
facts must be considered: Standard and welding pad gages will withstand a loading
due to the pressure within the gage itself, but they are not designed to replace the
tank strength lost with tank wall is cut. SIGMA has no control over the loading in which
the pressure vessel will impose on the pad. It is therefore impossible to rate welding
pad gages. The tank fabricator must provide suitable tank wall reinforcement to
prevent the pad from being distorted during welding or while under hot operating
condition.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Gauge Construction
Type : Reflex / Transparent. Off Set Valves: Having an advantage of permitting the inside of
Liquid Chamber : Carbon Steel, Rubber / Teflon lined SS 304, the gauge glass to be cleaned easily with minimum disassembly,
SS 316, SS 304L, PVC / PP / Monel / by removing vent and drain plugs (or other connection), a straight
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Type CC in mm
ARLG - Reflex Example 1200 mm
ATLG - Transparent
Special Features
N - None E - Expansion Loop
Design F - Frost Shield R - Rubber Lined
S - Standard M - Mica Shield C - Internal Cooling
L - Large Chamber I - FP Illuminator Tube
U - Uninterrupted visibility T - Teflon Lined
W - Weld Pad
Note
- Auto shut off valve are un lined / uncoated by virtue of design. In case valves are not opted in lined chambers,
isolation valves may be provided for maintenance.
- Lined / Coated versions are available in large chamber model only by virtue of design.
- Lined / Coated level gauges shall have Flanged process connection only.
- Model Coding is categorized as per the specification of the product, for ease of selection and ordering.
- In case of choosing multiple specification under a specific category, mention the 2nd / 3rd code with a bracket, after the 1st code.
For ordering IBR approved product, mention "IBR" immediately after the Product code.
- The product conforms to 97/23/EC: Pressure Equipment Directive, Article 3.3 Sound Engineering Practice.
- In case of doubt, contact SIGMA for assistance in arriving at the model code / for specification.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Material of Additional CC
MLG Orientation Connection
Construction Features (in mm)
Note
- Model Coding is categorized as per the specification of product, for ease of selection & ordering.
- In case of choosing multiple specification under a specific category, mention the 2nd / 3rd code with a bracket, after the 1st code.
- For ordering IBR approved product, mention "IBR" immediately after the Product code.
- The product conforms to 97/23/EC: Pressure Equipment Directive, Article 3.3 Sound Engineering
practice and 2006/95/EC: Low Voltage Directive (LVD)
- In case of doubt, contact SIGMA for assistance in arriving at the model code / for specification.
Note
All the Magnetic Level Gauge mentioned in this catalogue are our
standard design. If the standard items do not meet your
requirements, we can modify them to meet your specifications and
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Sigma Advant-edge
Specifications
Recommended Pressure The principle of liquid maintaining the same level makes this
Length in mm in kg/cm2 system very precise and reliable. The fluid attains its level in the
glass tube of the level gauge as that of the vessel and is viewed
250 30 through the glass tube. SIGMA Gauge Valves form a major
500 25 component of the tubular glass gauges. Two gauge valves at
750 20 the ends of the glass tube are connected to the tank. Under
1000 16 normal operations, the valves are kept wide open causing the
1250 11 pressure to equalize in the system thus permitting the liquid to
1500 5 seek its true level for observation along the visible length.
1750 5
2000 4
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Note
- Model Coding is categorized as per the specification of the product, for ease of selection and ordering.
- In case of choosing multiple specification under a specific category, mention the 2nd / 3rd code with a bracket, after the 1st code.
- For ordering IBR approved product, mention "IBR" immediately after the Product code.
- Bolted Bonnet option is only available in Offset Valves (CS/SS).
- The product conforms to 97/23/EC: Pressure Equipment Directive, Article 3.3 Sound Engineering Practice.
- In case of doubt, contact SIGMA for assistance in arriving at the model code / for specification.
Note
All the Tubular Level Gauge mentioned in this catalogue are our
standard design. If the standard items do not meet your
requirements, we can modify them to meet your specifications and
able
Avail would appreciate the opportunity of making suggestions to cover
your application, based on engineering principles. SIGMA reserves
IBR Approved
the right to modify specification / design from time to time, which
Tubular Level Gauge
TUV India Private Ltd.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
25
Sigma A-Acrylic S - Single 4-SS304 1 - M12
Oil Level G- Glass D - Double 6-SS316 2 - M8
Gauge
C-CS S - Others
specify
Note:
- SIGMA reserves the right to modify specification / design
from time to time, which is deemed suitable for the product
25
without prior intimation.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Sigma Advant-edge
Easy installation.
Specifications
200 1000 ml
Tension Spring Assembly : Carbon Steel / SS 304 / SS 316. 300
600
1200 ml
1900 ml
Aluminum / Specified
Liquid seals are used for application where
Pulley Housing : AL / CI / SS. • Product stored is volatile • Inert gas blanketing in tank
Guide Tube : CS / SS. • Vapor pressure is in excess but less than above listed mm of
Scale : Aluminum. Water column Approximate volume of sealing liquid is
Pointer : AL / SS. produced in the table.
Counter weight : CI / SS. Note: Transformer oil / liquid paraffin is provided if required.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Sigma Advant-edge
Mounting Arrangement
of Floating Roof Tank
Ease of maintenance, major cost reductions
Float Wire
No specific restrictions on the number of switches. Attached to Pointer
NO PROCESS CONTACT.
Scale Board
Switching area is isolated from the process liquids.
Pointer
Type : 2 SPDT, Micro, 10 A @ 250 V AC /
0.2 A @ 250 V DC
Pull Chain
On / Off Differential : within 25 mm Side Mounted
Level Switch
Switch enclosure : Die cast Aluminum IP 67 /
Flame proof Group IIC
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Model Number Coding for Float Level Indicator (optional Level Switch)
Float Level Indicator, with All the Float Level Indicators / Float Level Indicator with Level
- Full Scale Type Switches mentioned in this catalogue are our standard design. If
- Overhead Design the standard items do not meet your requirements, we can modify
- Connection Flanged (specify Connection Details & Size) them to meet your specifications and would appreciate the
- SS 304 Float opportunity of making suggestions to cover your application, based
- Vapour / Liquid Seal Assembly on engineering principles. SIGMA reserves the right to modify
- 0-4m specification / design from time to time, which is deemed suitable
for the product without prior intimation.
Note
- Model Coding is categorized as per the specification of the product, for ease of selection and ordering.
- In case of choosing multiple specification under a specific category, mention the 2nd / 3rd code with a bracket, after the 1st code.
- For ordering Level Switch with Float Level Indicator, specify the number of Level Switches required.
- In case of doubt, contact SIGMA for assistance in arriving at the model code / for specification.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Automatic Tank Level Gauge (Float & Tape Type) August Series
SIGMA’s AUGUST series Automatic Tank Gauges are designed to provide continuous liquid level measurement
for bulk storage applications. The AUGUST is a float actuated instrument that provides continuous and reliable
liquid level measurement, specifically engineered to reduce maintenance and enhance reliability.
In principle, the AUGUST utilizes a large stainless steel float that is attached to a perforated stainless steel tape to detect the liquid level.
The float traces the liquid level rise and fall due to the constant pull-back tension force provided by a power spring. The precisely perforated tape
engages pins on a sprocket drive wheel that in turn drives the measurement counter mechanism. The float is guided between the guide wires
that are kept straight/kink free through the tension devices. Alternatively, still wells that shall guide the float can be used where
there is no provision for guide wires. This simple, rugged design makes the gauge to perform with negligible maintenance throughout its
working life.
DRAIN
(TOP MOUNTING)
TAPE
POWER WHEEL
TAPE STORAGE TAPE ENTRY, SIDE MOUNTING
POWER SPRING
GAUGE HEAD
STORAGE WHEEL
GAUGE CHECKER
SPROCKET DRIVE
TAPE KEEPER
003
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Gauge Shaft seals for oil filling: Gauge Body : Cast Aluminum Epoxy Powder Coated.
AUGUST comes with an optional gauge shaft seals that allows Shaft : AISI 304.
the entire gauge head to remain in light oil, for longevity, smooth
Bearing : Brass/Delrin/Glass filled PTFE.
working and corrosion protection of main components in aggressive
environments or where tank vapors can peek inside
Counter : Thermoplastic Components.
the gauge head. Float : AISI 316/ specified.
Perforated Tape : AISI 316.
Gauge Check Handle/Striker: Guide wires : Multi Strand – AISI 316.
AUGUST comes complete with an easy to grip gauge check Tensional spring : Plated CS/ SS optional.
handle. The gauge check handle when turned deflects the tape in the
Tension Device : CS/GI/ optional materials as required.
sheave storage assembly, thus picking up the tape and the float. This
allows the testing of the power spring strength. It also is used for Bottom Anchor : CS/ AISI 304 / AISI 316/ optional
checking gauge calibration, plumbing of the float alignment, or materials as required.
freeing stuck-up gauges. Pulley Housing
(90° Elbow) : Cast Aluminium.
Tape Keeper: Pulley : Al / AISI 316 / specified.
AUGUST comes with a take keeper around the sprocket wheel
Shaft : AISI 304.
that allows tape to be installed simply by inserting the tape
around the tape keeper wheels. Pulley Bushing : PTFE/Nylon/Delrin.
Specifications
Tape Entry:
AUGUST gauge head is uniquely designed to allow tape entry for Range : 0-4M, 0-8M, 0-12M, 0-16M, 0-20M
both tank top mounting and tank-side mounting. The orientation (For higher range consult factory)
while mounting remains unchanged and so is the viewing direction. Indication : In millimeters ( 4 digit mechanical counter)
Temperature : 0 °C to 160 °C
Hoist Mechanism: Resolution : 1 mm
AUGUST with an optional hoist mechanism is used to hoist the
Accuracy : ± 2 mm with 300 mm diameter float for
float to facilitate easy tank maintenance. It is also used for high
liquid of specific gravity = 0.8 and above.
viscosity liquids or the liquids which may solidify at ambient
temperature. With the help of the hoist mechanism, the float is Protection : Weatherproof to IP-65 as per IS:2147-1962
lowered at the time of measuring the level and is hoisted again.
Note
Gauge Body Protection:
AUGUST comes with epoxy powder coating to reduce the All the Automatic Tank Level Gauge mentioned in this catalogue are
amount of moisture entering the gauge head through normal our standard design. If the standard items do not meet your
breathing of the aluminum housing. It effectively seals the unit requirements, we can modify them to meet your specifications and
from water penetration. would appreciate the opportunity of making suggestions to cover
your application, based on engineering principles. SIGMA reserves
Note: AUGUST Gauge head is a purely mechanical device, hence the right to modify specification / design from time to time, which is
enclosure as per IS:2147 is not applicable for this item. deemed suitable for the product without prior intimation.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Installation Options
PULLEY HOUSING
GAUGE HEAD
003
TENSION DEVICE
TENSION DEVICE
SUPPORT
FLOAT
FLOAT
GAUGE HEAD
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Model Number Coding for Automatic Tank Gauge (Float & Tape Type) Level Gauge
ATLG
(Automatic Tank Gauge)
Type
S - Standard Optional
W - With Hoist Mechanism L - Liquid Seal Assembly
G - Gauge Head oil filled S - Limit Switches
A-2+3 Float T - 2 wire Transmitter
N - None a
Mounting 1 - Ø150 mm for Still Well, AISI 316 b
T - Top of Tank 2 - Ø300 mm AISI 316 b
S - Side of Tank 3 - Ø375 mm AISI 316 b
F - Floating Roof 4 - Interface Float AISI 316 b
O - Others specify A - Others specify
Range
1- 0 - 4000 mm 4. 0 - 16000 mm Guide Rods a,e,f
2 - 0 - 8000 mm 5. 0 - 20000 mm N - None d 5 - CS
3 - 0 - 12000 mm A - Specified 4 - SS304 6 - SS316
Process Connection
1- 1 ½” BSP(M) CS A - others specify Tension Device
2 - 1 ½” NPT(M) CS N - None 3 - SS316 with SS Spring
3 - 1 ½” Flanged A 105 ANSI B 16.5 1 - CS with CS Spring A - Others specify
2 - SS 304 with SS Spring
Automatic Tank Gauge (Float & Tape Type) Level Gauge, with
- Standard design - Tension Device (SS 304 with SS Spring)
- Mounting on Top of Tank - SS 304 Guide Rod
- 0 -4000 mm Range - Ø 375 mm AISI 316 Float
- Process connection 1 ½”BSP (M) CS - Liquid Seal Assembly
a. Guide Wires/Tension devices/Float are NOT required for floating roof tanks. Floats are required if Floating roof with float wel l is
used. In this case, Guide rods may be used based on floating well tank dimensions. Accuracy of floating roof will depend purely
on roof/float well movement. In case of floating roof the tape is attached to the floating roof itself. In floating roof tank installations,
it is recommended that gauges be installed in a float well, rather than attaching the tape directly to the tank roof. The float well should
contain a baffle to prevent the float from escaping, but also allow sufficient product movement to equalize the liquid level. No tape
should be exposed outside of the roof or pipe work. If any section of the tape is currently exposed it should be replaced with a SS
flexible cable,this will reduce measurement error due to wind drift. The connector between the tape and cable should not run over
a conduit elbow (or pulley).
b. Accuracy for the ATLG with : 300 mm diameter float is 2 mm, with 15 mm diameter float is 20 mm
c. Interface float is applicable only for liquids with difference in densities = 0.2 gm/cc.
d. Guide wire/ tension devices, guide rods and bottom anchor are not required when Stilling well for float is provided.
e. In case guide rod option is chosen, no bottom anchor is required.
f. For retrofitting on existing tanks, guide rod assembly (up to 3 M) or weighted bottom anchor (above 3 M) is recommended.
This installation must be done on manhole cover.
g. Gauge Head support brackets, GI Horizontal pipe for pulley , pu lley connections, GI vertical pipe, and 3 Nos tank wall support
with U bolts for pipe work is part of the supply for side moun tingversions. Piping for side mounting can be provided on request.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Sigma Advant-edge
Specifications
Rating : 10 A @ 250 V AC ,
0.2 A @ 250 V DC / specified. .
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Note
- Model Coding is categorized as per the specification of the product, for ease of selection and ordering.
- In case of choosing multiple specification under a specific category, mention the 2nd / 3rd code with a bracket, after the 1st code.
- For ordering IBR approved product, mention "IBR" immediately after the Product code.
- In case of doubt, contact SIGMA for assistance in arriving at the model code / for specification.
- The product conforms to 97/23/EC: Pressure Equipment Directive, Article 3.3 Sound Engineering Practice and 2006/95/EC:
Low Voltage Directive (LVD)
Note
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Sigma Advant-edge
Specifications
ilable
Ava
In Sealed chamber Level Switch, the Float Chamber is completely
sealed with float inside the chamber. By virtue of sealed cable entry,
IBR Approved
the switch can be used for refrigerants, with low specific gravity.
External Cage Level Switch
TUV India Private Ltd.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
External Cage Level Switch, with SIGMA reserves the right to modify
specification / design from time to
- Side-Side orientation - Weather Proof Enclosure
time, which is deemed suitable for
- Flanged Connection (specify size & rating) - Switch rating 15 A, 250 V AC, 0.25 A, 250 V D.C
the product without prior intimation.
- Operating Pressure up to 15 kg/cm2 - Cooling Fins
- SS 304 Cage- - 150 mm c/c
- with one float
Note
- Model Coding is categorized as per the specification of the product, for ease of selection and ordering.
- In case of choosing multiple specification under a specific category, mention the 2nd / 3rd code with a bracket, after the 1st code.
- For ordering IBR approved product, mention "IBR" immediately after the Product code.
- 2 SPDT Switch with 10A @ 250V AC, 0.2 A @ 250V DC is supplied as standard.
2.
- PP (50 0 C) / PVC / Teflon max pressure rating is 8 Kg/cm - PP/PVC/Teflon switches are available with single float option only.
- The product conforms to 97/23/EC: Pressure Equipment Directive, Article 3.3 & 2006/95/EC:Low Voltage Directive (LVD)
- In case of doubt, contact SIGMA for assistance in arriving at the model code / for specification.
C/C
C/C C/C
C/C
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
ilable
Ava
IBR Approved Ÿ X Ÿ X
X
Ÿ X
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Optional
N - None
TMLS P - Plug & Socket
Type C - Cooling Fins
A - Single Level AB - Three Level S - Specified
B - Two Level BB - Four Level Enclosure Class
C- Single Level with wide differential W - Weather Proof
D- Two Level with wide differential F - Flame Proof
Ÿ
- SS 304 Flange - Plug & Socket X
X
- Flange Size 80 NB - Standard: 2 SPDT Switch is provided Ÿ X
Note Style
BB
- Model Coding is categorized as per the specification of the product, for ease of selection and ordering.
- In case of choosing multiple specification under a specific category, mention the 2nd / 3rd code
with a bracket, after the 1st code.
- For ordering IBR approved product, mention "IBR" immediately after the Product code.
2 0
Ÿ X
- PP/PVC/Teflon max pressure rating is 10Kg/cm - PP max temperature rating is 50 C
Ÿ
- The product conforms to 2006/95/EC: Low Voltage Directive (LVD) per Harmonized standard X
- In case of doubt, contact SIGMA for assistance in arriving at the model code / for specification.
Ÿ X
- SIGMA reserves the right to modify specification / design from time to time, which is deemed
suitable for the product without prior intimation.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Cost effective level detection Float / Stem : SS 304 / SS 316, PP, PVC /
Terminal enclosure - weather proof specified material
Collars prevent false switch re-operation due to over travel of float Terminal Enclosure : Weather Proof / Flame Proof
SPST or SPDT REED Switches Terminal Enclosure Material : Cast Aluminum / Plastic
Immune to electrical disturbance Contact : Hermetically sealed REED,
Unaffected by liquid characteristics SPST or SPDT
ilable
Ava
IBR Approved
Level Switch (REED Type)
TUV India Private Ltd.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Model Number Coding for Top Mounted Level Switch (REED Type)
Only Single Level is available in Side Mounted Level Switch (REED Type)
Top Mounted Level Switch Reed Type, with All the Level Switch (REED Type) mentioned in this
- Two Level catalogue are our standard design. If the standard items
- Operating Pressure up to 3 kg/cm 2 do not meet your requirements, we can modify them to
- Weather Proof enclosure reserves the right to modify specification / design from
- 1 SPDT Switch time to time, which is deemed suitable for the product
Note
- Model Coding is categorized as per the specification of the product, for ease of selection and ordering.
- In case of choosing multiple specification under a specific category, mention the 2nd / 3rd code with a bracket, after the 1st code.
- For ordering IBR approved product, mention "IBR" immediately after the Product code.
- The product conforms to 2006/95/EC: Low Voltage Directive (LVD) per Harmonized standard EN 61010-1/1993 & Amendment No.1
- Side mounted option is available in Single Float Type.
- In case of doubt, contact SIGMA for assistance in arriving at the model code / or specification.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Sigma Advant-edge
No Moving parts
Power Supply Indication
LED Indication / Relay Output for 4 different preset levels
Selectable high / low level alarm
Special probe design to tackle acids.
Latching type relay design for direct auto pump operation
Auto sensitivity to liquid conductivities > 25 µs
Option of stand alone system
Specifications
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
While ordering, specify Process Connection Material, size (Flange or Thread) and Flange rating
Note
- Model Coding is categorized as per the specification of the product, for ease of selection and ordering.
- In case of choosing multiple specification under a specific category, mention the 2nd / 3rd code with a bracket, after the 1st code.
- In case of doubt, contact SIGMA for assistance in arriving at the model code / for specification.
Note
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Side Mounted : (with / without cage) Top Mounted : Float/ Displacer (with/without cage)
Buoyancy force of process liquid on a float causes the float to move Operation is based upon simple buoyancy, whereby a float or a
with the liquid's surface. Float movement pivots a magnet into the spring loaded weighted displacer rises following the liquid level. A
field of a like-charged switch magnet. As the magnets repel each magnetic sleeve, connected to the float / displacer, moves up and
other, the switch magnet moves, actuating the switch. operates within a non-magnetic enclosure tube. The magnetic sleeve
Free swinging float arm attracts a pivoted magnet, actuating a switch mechanism located
- No cavities to clog (eliminates “Float Stick”) out-side the enclosure tube to give NO or NC changeover. A fall of
liquid level will de-actuate the switch mechanism
Magnetically activated
- No seals to maintain / No leaks / No fugitive emissions.
Specifications
Pneumatic Level Switch the right to modify specification / design from time to time, which is
deemed suitable for the product without prior intimation.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Operating principle
Specifications
Span (L) : up to 3 m / specified.
Resolution : 10 mm
Mounting : Top
Enslosure : Cast Aluminum Weather proof to
IP 67 or Explosion proof IIA & IIB.
Conduit Connection : Brass, 3/4" ET or 1/2" NPT
Wetted Parts : SS304, SS316, PP / specified.
Float(Material & Size) : Suitable for process parameter.
Process Connection : 2" and above Flanged or
threaded to ANSI / BS / DIN std.
Output : DC 4-20 mA (isolated) or
1 to 5 VDC (optional).
Wiring System : 2 Wire
Model No.Coding - Magnetic Float Operated Level Transmitter
Temperature :1000C / Specified
Test Pressure :10 kg/cm2 / Specified. Process Wetted Range
SIML-TX (mm)
Connection Parts
Optional :Process Indicator with alarm.
Application : Storage Tanks (Fuel, Oil, Chemical, Water),
Sigma F - Flanged 4-SS304 Specify
Pressurized Vessels, Waste Water Treatment Plant. Magnetic S - Screwed 6-SS316 in meter
Float
P-PP
Sigma Advant-edge Operated
S-other
Level
Continuous 'Float Type' Analog Sensor, in materials, resistive specify
Transmitter
to most liquids
While ordering, specify:
Pre calibrated at factory-No Field Calibration required 1. Process Connection Material & size (Flange or Thread)
4-20 mA, 2 wire processed output signal and Flange rating.
2. Conduit Connection
High Resolution & Repeatability
Liquid level or liquid / liquid interface detection
Length up to 3.5 m, RS-232, RS-485 compatible
NOTE: SIGMA reserves the right to modify specification / design TUV India Private Ltd.
from time to time, which is deemed suitable for the product without
prior intimation.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Sigma Advant-edge
Specifications
ilable
Ava
IBR Approved
Sight Flow Indicator
TUV India Private Ltd.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Sight Flow F-Flapper F-Flanged 1-Upto T- Toughened 2-IS 2062 N-None Specify size &
R-Rotor T- Threaded 15 kg/cm2 Indigenous 5-A105 J-Heating / Rating for
P-Plain S-Socket S- Specify B-Borosilicate B-106 Gr.B Cooling Jacket example
D-Drip Lip Weld Pressure W-WCB 25 NB 150 #
O-Oil Tempered L- Lining/
or 40 NB SW
FV-Full View B-Butt Weld Sodium Silicate CI-Cast Iron Coating
or 20 NB NPT
B-Ball Type A-Alumino 4-SS304 I-Illuminator
S-Specified Silicate 6-SS316 S-Specific
Q-Quartz 4L-SS304L Requirement
P-Acrylic 6L-SS316L F-with
P-PP Flow Switch
V-PVC
T-Teflon
S-Specified
Material
Note
- Model Coding is categorized as per the specification of the product, for ease of selection and ordering.
- In case of choosing multiple specification under a specific category, mention the 2nd / 3rd code with a bracket, after the 1st code.
- For ordering IBR approved product, mention "IBR" immediately after the Product code.
- The product conforms to 97/23/EC: Pressure Equipment Directive, Article 3.3 Sound Engineering Practice
- In case of doubt, contact SIGMA for assistance in arriving at the model code / for specification.
Note
All the Sight Flow Indicators mentioned in this catalogue are our
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
FLOW SWITCH
Sigma Flow Switch is an extension of the level switches. There are two types of flow switches : one for low flow / line size up to
50 mm line size (Model FS 1000) and another from 25 mm onwards up to 800 mm or above (Model FS 1010).
Operating Principle
Model FS 1000 is a valve type Flow Switch wherein an increase in flow through the body raises the valve disc depending upon
the flow. This in turn raises the magnetic sleeve moving inside a non-magnetic enclosure. The movement of the sleeve
attracts the magnet located outside the tube which in turn actuates a micro switch. Decrease in flow reverses the action.
Model FS 1010 is a target type which moves from a vertical position to a near horizontal position as the flow increases. This
change in position moves a magnetic sleeve in a non-magnetic enclosure. The movement of the magnetic sleeve attracts a
magnet which in turn actuates a micro switch. Decrease in flow brings the target back to the vertical position.
Application:
The Flow Switches are used to sense the start or stop of non-viscuos liquid flow like water, gas, chemicals or any other
flowing medium. They are used in interlock systems for ensuring minimum flow through pipe lines before starting
equipments. In cooling water these flow switches are used to shut down the pumps, blowers, fans should the flow decreases
below a predetermined limit.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Specifications
Note:
- Specify Line size, Material of Construction, along with Model number for ordering.
- Spool piece for Model F1010 directly connecting the flow switch in between the
pipeline will be supplied with or without Sight Windows only if ordered separately.
Flow Switches are available from 15 mm to 800 mm or more All the Flow Switch mentioned in this catalogue are our standard
Flow actuation point field adjustable when switch is in operation design. If the standard items do not meet your requirements, we
Flanged or screwed connection can modify them to meet your specifications and would appreciate
By trimming the vane length, the same flow switch can be used the opportunity of making suggestions to cover your application,
for smaller line size in model FS 1010. based on engineering principles. SIGMA reserves the right to
Magnetic coupling eliminates diaphragm or bellows of modify specification / design from time to time, which is deemed
conventional switches.
suitable for the product without prior intimation.
Sight windows can be provided for model FS 1010 to have visual
observation of the flow.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Specification (Size)
Note
All the Condensate / Seal Pot mentioned in this catalogue are our
P3 P4
standard design. If the standard items do not meet your
requirements, we can modify them to meet your specifications and
would appreciate the opportunity of making suggestions to cover
P5 P6
your application, based on engineering principles. SIGMA reserves
the right to modify specification / design from time to time, which is
deemed suitable for the product without prior intimation from time
il able
Ava
IBR Approved
Condensate Pot
TUV India Private Ltd.
P2
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Note
- Model Coding is categorized as per the specification of the product, for ease of selection and ordering.
- For ordering IBR approved product, mention "IBR" immediately after the Product code.
- In case of doubt, contact SIGMA for assistance in arriving at the model code / for specification.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
MANIFOLDS
Note
SIGMA reserves the right to modify specification / design from time
to time, which is deemed suitable for the product without prior
intimation from time to time.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
INSTRUMENTATION FITTINGS
Note
SIGMA reserves the right to modify specification / design from time
to time, which is deemed suitable for the product without prior
intimation from time to time.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
NEEDLE VALVES
Sigma’s Needle Valve are available in two way, three way,
multiport, single block & bleed, double deck and bleed. These
Needle valves are available in variety of end connections screwed
male/female pipe ends which confirm to ferrule designs.
Valves as per custom needs with any end connections, for
pressure ranging from 10 kg/cm2 to 700 kg.cm2, can be offered.
Isolation needle valve upto 10000 PSI are available for hassle free
long life in process lines. These valves can be used to isolate,
calibrate and drain the process lines.
Material of Construction:
SS 316, SS 304, Brass, Carbon Steel, Monel, Hastalloy.
Range:
1/8” to 1” threaded. 1/8” OD to 1” OD suitable for tube end.
4 mm OD to 25 mm OD suitable for tube end.
End Connection: NPT / BSPT / BSP.
For Ordering Code / Model No., contact Sigma with the
Valve specification.
Note
SIGMA reserves the right to modify specification / design from time
to time, which is deemed suitable for the product without prior
intimation from time to time.
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
CUSTOM PRODUCTS
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566
SIGMA INSTRUMENTS COMPANY Office: 201, Anandraj Industrial Estate
Sonapur Lane, Bhandup (W), Mumbai 400078. INDIA. | Tel.: +91 22 2566 0555
Fax: +91 22-2566 3285 | www.sigmainstruments.co.in | sales@sigmainstruments.co.in
Tank Level & Flow Instrumentation Products
Specifications
APPLICATION
Cable Material : PVC / Neoprene.
Maximum Load : 10 A 250 V AC.
Contact Type : micro switch with NO & NC contact. Pump Protection
Switch Angle : ± 450.
Temperature : 0 - 500C / Specified.
Test Pressure : 1 kg/cm2 / Specified.
Specific Gravity (Liquid) : 0.8 and above.
Enclosure : PP
Protection : IP 68.
Process Connection : 6”Flanged or specified.
(if required)
Cable length : 5 / 10 / 15 m.
Filling Control
Model No.Coding - Cable Float (Tilt type) Level Switch High Switch Level
Differential
SICF
Material Length (m) Connection
Works: 27, Nahur Udyog Indl Permises, M. M. Malaviya Road, Mulund(W), Mumbai - 400080. INDIA . | Tel. : +91 22 2591 8567 | Fax : +91 22 2591 8566