www.huawei.com
Objectives
Know the function of performance management in M2000 Operate performance management via M2000
Page1
Contents
1. Performance Management Basic 2. Performance Management Preferences 3. Performance Database Capacity Parameters 4. Measurement Management
Page2
Overall Procedure of PM
Threshold Alarm Generated Northbound Export Threshold Exceeded? Export Results to Server Display Results Threshold Check
Mediation Analysis
M2000 Server
Northbound Export
NEs
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved. Page3
Results Missing ?
Display Results
Mediation Analysis
Performance Data
NEs
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved. Page5
Three factors of PM
Counter
WHAT
Object
WHO
Period
WHEN
Page6
Three factors of PM
Object(Logical concept)
Period
Counter
Page7
Function set 1
P E R F O R M A N C E
Function subset 1
Counter 1
Function subset m
Counter j
Counter 1
Function set n
Counter k
Page8
Function set
Counter
Function subset
Page9
Contents
1. Performance Management Basic 2. Performance Management Preferences 3. Performance Database Capacity Parameters 4. Measurement Management
Page10
PM Preferences
or
Page11
Contents
1. Performance Management Basic 2. Performance Management Preferences 3. Performance Database Capacity Parameters 4. Measurement Management
Page12
Page13
Display Results
Performance Database
M2000 Server
Page14
Contents
1. Performance Management Basic 2. Performance Management Preferences 3. Performance Database Capacity Parameters 4. Measurement Management
Page15
Step 2
Query Result
By new condition
By template
Page16
Measurement Setting
Page17
Measurement Setting
Object Period Counter
The system automatically issues measurement tasks to the new objects or new NEs
Page18
Contents
1. Performance Management Basic 2. Performance Management Preferences 3. Performance Database Capacity Parameters 4. Measurement Management
Page19
Customer Counter
According to the existent measurement counters, to define a user-required measurement counter by using the arithmetic.
Page20
Customer Counter
Customer Counter
Put the constant in parenthesis For example: (Counter1+Counter2)*{100}/(Counter3+Counter4+Counter6) The candidate original counters
Page22
Contents
1. Performance Management Basic 2. Performance Management Preferences 3. Performance Database Capacity Parameters 4. Measurement Management
Page23
Page24
Page25
If some objects were deleted, the history results can be queried by this way
After condition setting, we can save it as query template
Page26
Query by Template
Page27
Contents
1. Performance Management Basic 2. Performance Management Preferences 3. Performance Database Capacity Parameters 4. Measurement Management
Page28
Other Functions
Browse measurement status Query missing result Manage integrity Synchronize result
Additional functions
Page29
Legend
Page30
Page31
or
or
Page32
Managing Integrity
Integrity monitor
Integrity query
Page33
Integrity Monitor
Page34
Integrity Monitor
Page35
Integrity Query
Page36
Integrity Query
Page37
measurement results. (via the dialog box in this page or next page)
way1
Page38
way2 way3
Page39
Page40
Benefits
Monitor the actual measurement result of the counters. When the value of the measurement result exceeds that threshold set by the user, the system generates an alarm.
Types:
Simple threshold
Combined threshold
The threshold defined for the value obtained by logic or arithmetic operations of multiple counter values.
Page41
Simple Threshold
Page42
Threshold Alarm
110 100 90
Minor Alarm Critical Alarm Cleared
45 40
35
t1 t2 t3 t4 t5 t6 t7
t8 t9
Threshold Alarm
110 100 90
Critical Alarm Cleared
Minor Alarm
45 40
Critical Alarm
35
t1 t2 t3 t4 t5 t6 t7 t8 t9
Page44
t10
Combined Threshold
Page45
Combined Threshold
Counter name is changed according to the Fileter by Counter Type
Logic combination
Page46
Day
Period
2. Use the template function to get a traffic statistic result and satisfy the condition listed above.
Page47
Function Set: MR Measurement Function Subset: Uplink-and-Downlink Balance Measurement per TRX Counter A:
S462A +S462B+S462C+S462D+S462E+S462F+S462G+S462H+S462I+S462J+S462K
100
Counter B:
S462A +S462B+S462C+S462D+S462E+S462F+S462G+S462H+S462I+S462J+S462K
100
Page48
Threshold type
Direction Function subset
Simple
Decreasing Call Measurement / KPI Measurement per Cell
Counter name
Threshold Hysteresis
Page49
Page50
Summary
Page51
Thank you
www.huawei.com