Anda di halaman 1dari 4

14/03/12

MBTS Product Documentation

WMPT
This describes the WCDMA Main Processing and Transmission unit (WMPT). It is the BBU3900 main control and transmission board that processes the signals and manages the resources for other boards.

Panel
Figure 1 shows the WMPT panel. Figure 1 Panel of the WMPT

Functions
The WMPT has the following functions: Providing Operation and Maintenance (OM) functions such as configuration management, equipment management, performance monitoring, signaling processing, and active/standby switchover and providing OM channels connected to the OMC (LMT or M2000) Providing the reference clock Processing signaling and managing resources for other boards in the BBU3900 Providing USB ports, one of which facilitates automatic BBU3900 upgraded when a USB disk is inserted during software installation and data configuration Providing four E1s/T1s which support ATM and IP protocols Providing one FE electrical port and one FE optical port which support the IP protocol Supporting cold backup

LED
Table 1 describes the LEDs on the WMPT panel. Table 1 LEDs on the WMPT Label RUN Color Green Status ON Meaning The power input is available, but the board is faulty. The power supply is unavailable. The board in normal configuration is running properly. The software is being loaded to the board, or the board is not in use. No alarm is generated. The board has alarms on hardware. The board is in active
1/4

OFF 1s ON and 1s OFF

0.125s ON and 0.125s OFF ALM Red OFF ON ACT Green ON

127.0.0.1:52199/hedex/hdx.do?lib=31184479&v=01 (2010-05-04)&id=&tocURL=resources%252fbb

14/03/12

MBTS Product Documentation

OFF

mode. The board is in standby mode.

In addition to the previous three LEDs, the WMPT has another six LEDs indicating the connection status of the FE optical port, FE electrical port, and the commissioning Ethernet port. The six LEDs have no silk screen and are on both sides of each of the three ports. Figure 2 describes the LEDs beside the three ports and the status of the LEDs. Figure 2 LEDs besides the three ports on the WMPT

Table 2 describes the LED and its status. Table 2 LEDs beside the three ports LED LEDs beside the FE1 optical port Color Green (LINK) Status ON OFF Green (ACK) Blinking OFF LEDs beside the FE0 electrical port Green (LINK) ON OFF Yellow (ACK) Blinking OFF ETH Green (LINK) ON OFF Yellow (ACK) Blinking OFF Meaning The connections are functional. The connections are faulty. Data transmission is ongoing. No data transmission is ongoing. The connections are functional. The connections are faulty. Data transmission is ongoing. No data transmission is ongoing. The connections are functional. The connections are faulty. Data transmission is ongoing. No data transmission is ongoing.

Port
Table 3 describes the ports on the WMPT panel.
127.0.0.1:52199/hedex/hdx.do?lib=31184479&v=01 (2010-05-04)&id=&tocURL=resources%252fbb 2/4

14/03/12

MBTS Product Documentation

Table 3 Ports on the WMPT Label E1/T1 FE0 FE1 GPS ETH USB TEST RST Connector T pe DB26 connector RJ-45 connector SFP connector SMA connector RJ-45 connector USB connector USB connector Description E1 FE electrical port FE optical port Obligate Commissioning Ethernet port USB loading port USB testing port Resetting the BBU

DIP Switch
The WMPT has two DIP switches: SW1 for setting the E1/T1 working mode and SW2 for setting the protection grounding for the E1/T1 cables receiving 4-way signals. Figure 3 shows the DIP switches on the WMPT. Figure 3 DIP switches on the WMPT

Table 4 and Table 5 describe the settings of SW1 and SW2. Table 4 Settings of SW1 DIP Switch SW1 DIP Status 1 ON OFF 2 ON OFF 3 OFF ON 4 OFF ON T1 Mode The E1 impedance is set to 120 ohms.
3/4

Description

127.0.0.1:52199/hedex/hdx.do?lib=31184479&v=01 (2010-05-04)&id=&tocURL=resources%252fbb

14/03/12

MBTS Product Documentation

ON

ON

ON

ON

The E1 impedance is set to 75 ohms. Disabled

Other settings of the DIP bits

Table 5 Settings of SW1 DIP Switch SW2 DIP Status 1 ON ON 2 ON ON 3 OFF ON 4 OFF ON Balanced Mode Unbalanced Mode Disabled Description

Other settings of the DIP bits

CAUTION: All the DIP bits of SW2 are set to OFF by default. When four E1 links are faulty, you should set all the DIP bits of SW2 to ON so that the faults are rectified.

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

127.0.0.1:52199/hedex/hdx.do?lib=31184479&v=01 (2010-05-04)&id=&tocURL=resources%252fbb

4/4