Anda di halaman 1dari 25

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.

2_20140110

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Version

Date

Author

Approved By

Remarks

V1.0 V1.2

2014-01-10 2014-01-23

Huang Xiao Huang Xiao

Created modifications

2011 ZTE Corporation. All rights reserved. ZTE CONFIDENTIAL: This document contains proprietary information of ZTE and is not to be disclosed or used without the prior written permission of ZTE. Due to update and improvement of ZTE products and technologies, information in this document is subjected to change without notice.

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Catalogue
1. Introduction............................................................................................................................................ 4 1.1 Purpose............................................................................................................................................. 4 1.2 Scope................................................................................................................................................ 4 2. General Introduction of the BTS Upgrade Solution .............................................................................. 5 BPK board slot guideline ....................................................................................................................... 5 3. RF System upgrade Solution ................................................................................................................. 6 R8860E interface description:................................................................................................................ 7 R8881 Interface description ................................................................................................................... 8 3.1 RF system Swap Scenarios ............................................................................................................ 11 Scenario-1: 2G single band sector, FS board available for 3G. ................................................... 11 Scenario-2: 2G Single band 900M sector S4, FS board available for 3G. ................................... 12 Scenario-3: 2G Single band 1800M sector S1-S4, FS board available for 3G. ............................ 13 Scenario-4: 2G Single band 1800M sector S5-S6, FS board available for 3G. ............................ 14 Scenario-5: 2G Single band 1800M sector S7-S8, FS board available for 3G. ............................ 15 Scenario-6: Single band 1800M sector S9-S12, FS board available for 3G................................. 16 Scenario-7: Dual band 900M&1800M, S1-3, FS board available for 3G. ................................... 17 Scenario-8: Dual band 900M S1-S3, 1800M S4 or 900M S4 1800M S1-S4, FS board not available for 3G RRU .................................................................................................................. 18 Scenario-9: Dual band 900M S1-S4, 1800M S5-S6, FS board available for 3G. ........................ 19 Scenario-10: Dual band 900M S1-S4, 1800M S7-S10, FS board available for 3G. .................... 20 Scenario-11: Indoor micro site using BS8908. ............................................................................ 21 FS-RSU/RRU Relations Guideline ...................................................................................................... 22 4. Antenna solution ...................................................................................................................................... 23 1. TP Sharing sites........................................................................................................................ 23 2. TP Build sites. .......................................................................................................................... 23 5. Power Supply Solution ............................................................................................................................ 24 For 2G power supply, there are 2 scenarios as below: ......................................................................... 24 For distributed sites(BS 8700), A DCPD4 module will be configured for 3G RRU power supply ..... 24 For the Macro sites(BS 8900A), one 16A breaker will be changed to a 63A breaker for 3G RC cabinet .................................................................................................................................................. 25

Glossary:
RRU LPU OLP Remote Radio Unit Lightning Protection Unit Outdoor Lightning Protection

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

TOC

Top of Cabinet

1. Introduction
1.1 Purpose
This documentation will describe in detail the 3G site engineering solution from the existing ZTE 2G BTS to the 2/3G BTS/NodeB . This document is only valid together with all approved product manuals and engineering handbooks. Its purpose is to show a small variety of BTS upgrade solution in detail and to serve as quick reference for quality checks.

1.2 Scope
This documentation is customized for the Telenor Pakistan 3G project and based on 2G swap solution.

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

2. General Introduction of the BTS Upgrade Solution


For 3G sites, we just need to add BPK board (baseband board) in the existing 2G BBU and 3G RRUs/RSUs for the RF part. New RRU will be cascaded to existing RRU for saving FS board.

BPK board slot guideline


For the sites are using BS8700, BPK board will be normally configured at BBU slot 6. If there are 3 UBPG already configured, BPK will be configured at slot 5. If SE board is configured at slot 5, during upgrade, the 3rd UBPG will be moved to slot 4, then BPK could be plugged at slot 6. For the sites are using BS8900A, BPK board will normally be configured at BBU slot 6. If there are 3 UBPG already configured, BPK will be configured at slot5. If SE board is configured at slot 5, 3G will not be upgraded until original rectifier cabinet is swapped by W301 rectifier, so that the 8 external alarms can be provided by W301, then BPK could take slot 5 instead of SE board. BPK board will be prior plugged in BBU slot 6.

Figure- B8200 layout

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

3. RF System upgrade Solution


There are 11 RF system scenarios during the 2G Site Swap: Single Band 900M S1~S3 S4 S1~S4 1800M S5~S6 S7~S8 S9~S12 900M S1~3 S1~3 S4 S1~4 S1~4 1800M S1~S3 S4 S1~S4 S5~S6 S7~S10 MBR R8860E/R8881 (900M)+R8860E/R8881 (1800M) R8860E/R8881 (900M)+R8860E/R8881 (1800M) R8860E/R8881 (900M)+R8882(1800M) R8860E/R8881 (900M)+R8882(1800M)+R8860E/R8881 (1800M) MBR R8860E/R8881 R8860E/R8881 R8882 R8860E/R8881+R8860E/R8881 R8882+R8882 Dual Band Configuration

MBR is the Dual band R8882 which can work at both 900M and 1800M. For 3G RRU, only 2100M R8881 will be used. And which could be only cascaded with R8860E and R8881.

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

R8860E interface description:

The interfaces are described in the following table:

No 1

Label LC1

2 3 4

LC2 AISG Mon

Interface Interface type/connector BBU and RPU Interfaces/ RRU concatenation LC optical interface (IEC 874) interface BBU and RPU Interfaces/ RRU concatenation LC optical interface (IEC 874) interface AISG device interface External device interface 8-cores socket (IEC 60130-9-ED) 37-core aviation socket AC interface: Connector XCE18T3K1P1-02+FJJP1-7.5 Cable section area: 3*1 mm2 DC interface: Connector XCG18T4K1P1-01+XC18FJJP1-10.5 Cable section area: 4*1.5 mm2 50 ohms DIN-mode Connector 50 ohms DIN-mode Connector

PWR

Power supply interface

6 7

Interface to receive diversity RF cable Interface to RX/TX transmit/receive main diversity RF cable RX

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

No 8 9 10

Label RX out RX in GND

Interface Frequency expansion interface Frequency expansion interface Machine grounding

Interface type/connector N-KY (MIL-C-39012 or IEC169-16) N-KY (MIL-C-39012 or IEC169-16) Section area of cable is 16 mm2

R8881 Interface description

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

No. 1 2 3

Label Rx in Rx out

Interface Combined cabinet interface Protection ground interface

Interface/Connector N type connector N type connector 16 mm2 yellow/green round terminal DIN type connector DIN type connector LC type optical interface(IEC 874) LC type optical interface(IEC 874) 8-pin socket square plate installation

Applications Diversity receive signal input Diversity receive signal output Protection grounding

4 5

ANT1 TX/RX ANT2 RX OPT1

OPT2

Transmit/Receive antenna feeder interface Receive antenna feeder interface Interface for communication between the BBU and RRU RRU cascading interface AISG equipment interface

Connection with the antenna feeder

Signal transmission between the RRU and BBU

AISG

AISG signal connection for electrically tuning antenna

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

No.

Label

Interface

Interface/Connector

MON

MON external monitoring interface

8-pin round socket panel installation straight cable welding

Applications Signal interaction between the RRU and external equipment including alarming and RS485 control four pairs of dry contact inputs DC power input interface: provides -48 V DC power AC power input interface: provides AC power

10-1 PWR 10-2

Power input interface

10-1: R8881 DC chassis uses a 2pin round connector 10-2: R8881 AC chassis uses a 3pin round connector

11

LMT

O&M Ethernet interface

8P8C angle socket PCB shielded welding LED phone (LED RRU O&M and indicators: yellow for internal signal left indicator and output green for right indicator)

10

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

3.1 RF system Swap Scenarios

Scenario-1: 2G single band sector, FS board available for 3G.


For this scenario, MBR was used for GSM, while slot 3, 4, 5 of FS board is available for 3G RRU.

3G 2100M

900M

Jumper

MBR 3G R8881

ANT1 OPT1 ANT2 ANT1


Optical Fiber

ANT2

OPT1

11

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Scenario-2: 2G Single band 900M sector S4, FS board available for 3G.
For this scenario, R8860E/8881 was used for GSM, while slot 3, 4, 5 of FS board is available for 3G RRU.

3G 2100M

900M

Optical Fiber

Jumper

R8881

R8860E

ANT2 ANT1

OPT1

RX

RX/TX

LC1

12

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Scenario-3: 2G Single band 1800M sector S1-S4, FS board available for 3G.
For this scenario, R8860E/8881 was used for GSM, while slot 3, 4, 5 of FS board is available for 3G RRU.

3G 2100M

1800M

Optical Fiber

Jumper

R8881

R8860E

ANT2 ANT1

OPT1

RX

RX/TX

LC1

13

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Scenario-4: 2G Single band 1800M sector S5-S6, FS board available for 3G.
For this scenario, R8882 was used for GSM, while slot 3, 4, 5 of FS board is available for 3G RRU.

3G 2100M

1800M

Optical Fiber

Jumper

R8882 R8881

ANT1 OPT1

OPT1 ANT4

ANT2 ANT1

14

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Scenario-5: 2G Single band 1800M sector S7-S8, FS board available for 3G.
In this scenario, Two R8860E/8881 were cascaded by both optical fiber and cascading cable, While slot 3, 4, 5 of FS board is available for 3G RRU.

3G 2100M
Optical Fiber Cascading cable Jumper

1800M

R8881

R8860E

R8860E

LC1

RX/TX RX out RX in

LC1 LC2

RX/TX

RX in RX out

Figure

15

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Scenario-6: Single band 1800M sector S9-S12, FS board available for 3G.
Some VIP sites, two R8882 were cascaded for GSM, while slot 3, 4, 5 of FS board is available for 3G RRU.

3G 2100M
Optical Fiber

1800M

1800M

Jumper

R8882 R8881

R8882

ANT1 OPT1

ANT4

ANT1

ANT4 OPT1

OPT2 OPT1

ANT2

ANT1

Figure

16

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Scenario-7: Dual band 900M&1800M, S1-3, FS board available for 3G.


For this scenario, MBR was used for GSM 900M&1800M, while slot 3, 4, 5 of FS board is available for 3G RRU.

Optical Fiber

Jumper

3G 2100M

900M

1800M

R8881

MBR

ANT2

ANT1

OPT1

OPT1

ANT1 ANT2 ANT4 ANT3

17

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Scenario-8: Dual band 900M S1-S3, 1800M S4 or 900M S4 1800M S1-S4, FS board not available for 3G RRU
In this scenario, two R8860E/R8881 were cascaded for GSM 900M&1800M, slot 3, 4, 5 of FS board is not available for 3G RRU.

3G 2100M

900M

1800M

Optical Fiber

Jumper

R8881

R8860E

R8860E

LC1

RX

RX/TX

LC1

RX

RX/TX

LC1

LC2

Figure:

18

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Scenario-9: Dual band 900M S1-S4, 1800M S5-S6, FS board available for 3G.
In this scenario, one R8860E/R8881 was used for 900M; one R8882 was used for 1800M. While there is no FS port available for 3G RRU, The 3G RRU will be cascaded with R8860E/R8881.

3G 2100M

900M

1800M

R8882 R8881 R8860E

ANT1 ANT2 ANT1 OPT1 RX RX/TX LC1 LC2

ANT4 OPT1

19

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Scenario-10: Dual band 900M S1-S4, 1800M S7-S10, FS board available for 3G.
In this scenario, one R8860E/R8881 was used for 900M, one R8860E/R8881 and one R8882 were used for 1800M, and one R8881 will be used for 3G. The three R8860E/R8881 will be cascaded by Optical Fiber.

3G 2100M
Optical Fiber

900M

1800M

1800M

Jumper

R8882 R8881 R8860E R8860E

ANT1 ANT2 ANT1 OPT1 RX RX/TX LC1 LC2 OPT1

ANT4 RX RX/TX LC1

LC2

20

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

Scenario-11: Indoor micro site using BS8908/BS8700.


For this scenario, 2G is using BS8908/BS8700. 3G will build a new site co-site with 2G. RF part will use a combiner to combine 2G&3G to the splitter for indoor coverage.

GSM BS8908

TX/RX

Combiner

Splitter

UMTS R8881

ANT1

GSM BS8700

TX/RX

Combiner

Splitter

UMTS R8881

ANT1

21

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

FS-RSU/RRU Relations Guideline


In addition to RSU layout principles and connections between FS and RSU/RRU, the port connections between antennas and RSU/RRU should also be considered (such as the case of one RSU supporting one or two cells or two RSUs supporting one cell). a) RSU layout principles: 3G RSU The RSUs are placed into the cabinet from left to right (No slot leaves empty) in the following order: 3 empty RSU slots in the existing RC cabinet, 3G RSU will be installed in these slots by the order 4,5,6. No available slot for 3G RSU in the existing RC cabinet, a new RC cabinet will be added. The connections between FS and RSU/RRU should comply with the following rules: Fiber or SFP Cable connections between FS and RRU/RSU In case of using one FS card: The FS card is placed at slot3 of BBU. The ports of FS card are numbered from 0 to 5 (from right to left).The RSU/RRU units are connected to the FS ports in the following order from port No. 0 to port No. 5 (No port leaves empty): GSM 900 RSU/RRU in order of cells (lower at first) takes 0, 1, and 2 DCS1800 RSU/RRU in order of cells (lower at first) takes 3, 4, and 5 If there is no DCS1800M, UMTS 2100M will take FS 3,4,and 5. Otherwise, UMTS 2100 RRU will be cascaded with R8860E/R8881. For RSU, a new FS board will be configured.

b)

22

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

4. Antenna solution
1. TP Sharing sites.
For these sites, space on the tower is not available for installing the RRU and new antenna. In this case, A new RRU pole will be added on the ground, all the single/dual band antennas will be changed to Tri-band antennas.

2. TP Build sites.
For these sites, a new 2100M single band antenna will be added for each sector. a. Sufficient space on the tower, the 2100M antenna will be installed above 1800M antenna. b. Insufficient space on the tower, a diversity pole will be installed with 1800M antenna pole. 2100M antenna will be installed beside 1800M antenna.

23

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

5. Power Supply Solution


For 2G power supply, there are 2 scenarios as below:
Scenario1 For the Non EOL site, There is at least one breaker available on the original rectifier for BBU power supply(10A). All 8 output port can be used for 8 RRUs.

For the Non EOL site, there is no breaker available for the BBU power supply, The first port of DCPD4 will be used for BBU power supply, second port will be the backup for BBU, third port to eighth port used for RRU.

Scenario2 For the EOL site, 7 ports in LVLD can be used for RRU power supply.

For distributed sites(BS 8700), A DCPD4 module will be configured for 3G RRU power supply

24

RAN_ENG_3G Site Engineering solution (for the whole network) _V1.2_20140110

For the Macro sites(BS 8900A), one 16A breaker will be changed to a 63A breaker for 3G RC cabinet

The end

25

Anda mungkin juga menyukai