Switching to Terminal mode TPS Instrument


Step Action Screen Display Terminal Mode enables the user to enter data directly to the TST Instrument. Terminal Mode is ideal for users who like to switch easily between the instrument and the RX Controller. The Controller can be switched off and the TST used in 2person or Reflectorless modes. N.B. The RX Controller is set as a dumb terminal and merely mimics the display of the TST. The TST has to be switched on before the RX Controller can be used.

Place the Compact Flash card inside the TST Switch on TST and select 3 Management

Select 5 Configuration Sets

Select TCRP RCS RH1200 and press F1 CONT

Opti-cal Survey Equipment Ltd, 3 Orpheus House, Calleva Park, Aldermaston, Berkshire RG7 8TA Tel: +44 (0) 1189 820500 Fax: +44 (0) 1189 820520 Web: www.surveyequipment.com

Step

Action

Screen Display

Press 5 Config

Press 4 Interfaces

If there there is information displayed next to GeoCOM Mode, highlight it and and press F5 USE to switch off GeoCOM mode

Select RCS Mode and press F3 EDIT

-2Opti-cal Survey Equipment Ltd, 3 Orpheus House, Calleva Park, Aldermaston, Berkshire RG7 8TA Tel: +44 (0)1189 820500 Fax: +44 (0)1189 820520 Web: www.surveyequipment.com

Step

Action

Screen Display

Check the settings opposite and press F1 CONT

10

Press F4 CTRL

Check settings and then press F1 CONT until you return to the main menu screen 11 N.B. The TST has to be set as Remote in Smartworx mode

-3Opti-cal Survey Equipment Ltd, 3 Orpheus House, Calleva Park, Aldermaston, Berkshire RG7 8TA Tel: +44 (0)1189 820500 Fax: +44 (0)1189 820520 Web: www.surveyequipment.com

RX 1250TC Controller
Step Action Switch on the RX Controller Press SHIFT then F6 EXIT to leave Terminal mode and enter Windows CE screen. Double click the System 1200 Terminal icon. The Controller should connect automatically. However, if a warning: INFORMATION 1950 Unable to detect selected sensor appears on the screen then Press F2 CONF and select 3 Radio/ Comms Settings. Press F6 PAGE to select Parameters and check that the Link Number at the top of the screen is the same as that of the TST set earlier. Also check the bottom of the screen that it is Set as: Remote Press F4 OK to the CONFIRMATION 1954 warning Press 4 Work with Sensor Screen Display

12

13

14

You will see a flashing arrow icon above the a Terminal icon to show the TST is communicating with the RX Controller Press F12 Powersearch to find and lock to the prism

-4Opti-cal Survey Equipment Ltd, 3 Orpheus House, Calleva Park, Aldermaston, Berkshire RG7 8TA Tel: +44 (0)1189 820500 Fax: +44 (0)1189 820520 Web: www.surveyequipment.com