PF2 FILTER HOUSING

PF2 High Pressure In-Line Filter


Featuring Hy-Pro G6 Dualglass Filter element technology
APPLICATIONS
Hy-Pro PF2 pressure filters are ideal for protecting control valves and other sensitive components. Mobile applications such as waste haulers, cement mixers/pumpers, firetrucks, cranes, man lifts, etc. Power unit builders for pressure line. General industrial machine tools Paper mill and sawmill Primary metals Power generation applications for speed control circuit. Automotive manufacturing machine tools.

FEATURES, BENEFITS, ADVANTAGES


DFE rated elements G7 Dualglass and PE glass elements are DFE rated to assure performance even when exposed to the toughest hydraulic systems (See DFE literature for details) Circumferential Circumferential seal on the bowl o-ring bowl seal eliminates leading. (No Drips) Low housing Unique internal flow paths provide pressure drop low resistance to flow. (Low pressure drop) Coreless elements PF2 housings (with bypass valve option) can be ordered with Hy-Pro coreless filter element for easy disposal (crush or incinerate). Retro-fit kits available to convert conventional housings to coreless. HF2 compatible Port to port dimension, mounting pattern, and element design meet HF2 automotive specification. (Automotive standard) Drain plug standard Bowl with drain plug comes standard. (No price adder)

PRODUCT SPECIFICATIONS
4000 psi (207 bar) max operating 12000 psi (638 bar) burst Flow rate 20 gpm (75 lpm) max Design safety factor 3:1 Element collapse code 0: 150 psid (10 bar) code 1: 3000 psid (212 bar) code 04: 150 psid (10 bar) * *HP204 coreless element series Housing material Aluminum grade T6061 Fluid compatibility Compatible with all petroleum, (ISO 2948) based oils, HWBF, water glycol, oil/water emulsion, and specified synthetic fluids with Flurocarbon or EPR seals (call factory) Flow fatigue rating 2000 psi (178 bar) Differential pressure 50 psid (3.5 bar) standard indicator trigger Bypass valve crack 60 psid (4.2 bar) standard Weight (w/element) Single length bowl 3.8lb (1.7kg) Double length bowl 5.0lb (2.3kg) Temperature rating Nitrile = -40f(-40c) to 225f (107c) Fluoro = -15f(-26c) to 275f(135c)
www.filterelement.com

Pressure ratings

For technical service call 317.849.3535 or fax 317.849.9201

PF2 FILTER ASSEMBLY PART NUMBER GUIDE


table 1 table 2 table 3 table 4 table 5 table 6 table 7

PF2
PF2 FILTER ELEMENT PART NUMBER GUIDE
table 1 table 2 table 4 table 7

HP2
table 1 code 0 1 element collapse 150 psid 3000 psid table 4 code 1M 2M 3M 3SF 6M 10SF 12M 15M 25M 25W 40W 74W 149W 300W

L
filtration rating 2.5[c] = 1000 ( 1 = 200) 5[c] = 1000 ( 3 = 200) 5[c] = 1000 ( 3 = 200) 5[c] = 1000 ( 3 = 200) 7[c] = 1000 ( 6 = 200) 12[c] = 1000 ( 12 = 200) 12[c] = 1000 ( 12 = 200) 17[c] = 1000 ( 15 = 200) 22[c] = 1000 ( 25 = 200) 25u nominal 40u nominal 74u nominal 149u nominal 300u nominal

media type G7 Dualglass G7 Dualglass G7 Dualglass Dynafuzz G7 Dualglass Dynafuzz G7 Dualglass G7 Dualglass G7 Dualglass Stainless wire mesh Stainless wire mesh Stainless wire mesh Stainless wire mesh Stainless wire mesh series 20 21 20 20, 21 20,21 20,21 20 21 20,21 20,21 20,21 20,21 20,21 20,21 table 5 code 5 X table 6 code M E X Z bypass valve 60 psid (4.2 bar) No bypass

indicator Visual, mechanical Electrical No indicator port Indicator port plugged table 7 Seal Nitrile (buna)

table 2 code 4 8 table 3 code S M

length single double

port type 3/4" SAE-12 Manifold top mount

code B V

-40f(-40c) to 225f(107c) Fluorocarbon (viton) -15f(-26c) to 275f(135c)

FILTER MEDIA SELECTION GUIDE


code A media description "G7 Dualglass" combined with water removal prefilter layer Filtration rating Bx[c] = 1000, Bx = 200 "G7 Dualglass" is our latest generation of DFE rated, high performance glass media for use in all hydraulic fluids. Filtration rating Bx[c] = 1000, Bx = 200 "Dynafuzz" sintered stainless steel fiber media for high temp and corrosive applications. Filtration rating Bx[c] = 1000, Bx = 200 Stainless steel "W ire mesh" media, nominally rated. Hy-Pro filters are tested to the latest industry standard ISO16889 (replacing ISO4572) resulting in A new scale for defining particle sizes and determining beta ratio. New (ISO16889) vs Old (ISO4572) size comparison Bx(c)=1000 (ISO16889) Bx=200 (ISO4572) 2.5 5 <1 3 7 6 12 22 12 25

SF

For technical service call 317.849.3535 or fax 317.849.9201

www.filterelement.com

HIGH PERFORMANCE FILTER ELEMENTS THE HEART OF A FILTER Dynamic Filter Efficiency (DFE) Testing
Revolutionary test methods assure that DFE rated elements perform true to rating even under demanding variable flow and vibration conditions. Todays industrial and mobile hydraulic circuits require elements that deliver specified cleanliness under ALL circumstances. Wire mesh supports the media to ensure against cyclical flow fatigue, temperature, and chemical resistance failures possible in filter elements with synthetic support mesh. Contact your distributor or Hy-Pro for more information and published articles on DFE testing.

Coreless Element Technology


Hy-Pro original coreless elements, verified by Dynamic Filter Efficiency (DFE) Testing, utilize a synergy of synthetic components with wire mesh pleat support to yield an element that will incinerate without sacrificing performance under the toughest conditions. Retro-fit kits are available to convert conventional (core-in element) housings to coreless.

Media Options
Through extensive testing we have developed media choices to handle any application. Options include G6 Dualglass, PE Glass (impervious to phosphate ester), Dynafuzz (stainless fiber), and Wire mesh (stainless).

Fluid Compatibility
Petroleum based fluids, water glycol, polyol ester, phosphate ester, High water based fluids, and many other synthetics. Contact us for seal material selection assistance.

HOUSING and FILTER ELEMENT FLOW vs PRESSURE DROP and EFFICIENCY DATA
Empty housing Dp vs flow rate flow rate lpm 10 19 29 39 48 58 68 78 0.5 0.4 0.3 0.2 4 0 0 3 5 8 10 13 15 18 20 flow rate gpm 0.1 0 Dp bar

Pressure Drop Calculation


Pressure drop curves based on oil viscosity of 150 SSU, and specific gravity = 0.9. Dp across element is proportionally related to viscosity and specific gravity. For new DP use the following conversion formula: DP element = DP curve x Viscosity/150 x SG/0.86

0 16 12 Dp psi 8

204/20L8 Dualglass Dp vs flow rate flow rate lpm 0 10 19 29 39 48 58 68 78 8 6 Dp psi 4 2 25 0 0 3 5 8 10 13 15 18 20 1 3 6 12 0.5 0.4 Dp bar
Dp psi 8 6 4 2

204/20L4 Dualglass Dp vs flow rate 0 5 flow rate lpm 9 14 19 24 28 33 38


16

21L4/8 Dualglass Dp vs flow rate flow rate lpm 0 9 19 28 38 47 57 66 76 L4-2M L8-2M L4-15M 0.9 0.6 0.3 0 0 3 5 8 10 13 15 18 20 flow rate gpm Dp bar

0.5 1 3 6 12 25 0.4 0.3 0.2 0.1 0.0 0 1 3 4 5 6 8 flow rate gpm 9 10 Dp bar
12 Dp psi 8 4 0

0.3 0.2 0.1 0

L8-15M

flow rate gpm

For technical service call 317.849.3535 or fax 317.849.9201

www.filterelement.com

SPARE PARTS LIST and COMPONENT ILLUSTRATION


1

Head
In-line w/bypass valve, w/indicator port In-line w/bypass valve No indicator port In-line No bypass valve, w/indicator port In-line No bypass valve, No indicator port Top Mainfold w/bypass valve, w/indicator port Top Maniflod w/bypass valve, No indicator port Top Manifold No bypass valve, w/indicator port Top Manifold No bypass valve, No indicator port PF2HLBI PF2HLBX PF2HLXI PF2HLXX PF2HMBI PF2HMBX PF2HMXI PF2HMXX

Drain plug
Nitrile NBR o-ring Fluorocarbon o-ring EPR o-ring PF2DPB PF2DPV PF2DPE PFIVB PFIVV PFIVE PFIEB PFIEV PFIEE PF2SKMB PF2SKMV PF2SKME

Indicator
Visual, Nitrile o-ring Visual, Fluorocarbon o-ring Visual, EPR o-ring Electrical, Nitrile o-ring Electrical, Fluorocarbon o-ring Electrical, EPR o-ring

2 3

Element (see Element part number guide) Bowl seal kit (includes teflon back up ring)
Nitrile NBR Fluorocarbon EPR PF2BSKB PF2BSKV PF2BSKE PF2B1 PF2B2

Manifold mount kit (includes 2 o-rings)


Nitrile NBR o-ring Fluorocarbon o-ring EPR o-ring

Bowl
Single length w/drain port Double length w/drain port

Corless tube assembly (Call factory)

ELEMENT SERVICING
1. 2. 3. Stop power unit, verify zero system pressure. Verify temperature is safe to handle. Relieve pressure in the filter line and drain the bowl. 4. Remove the bowl. 5. Lube the new element o-ring. 6. Remove the element from the head. 7. Install a new element onto the post. 8. Check the bowl o-ring and replace if damaged. 9. Replace bowl, tighten/torque to 5-10 ft. lbs. 10. Start power unit and bleed air from system.

101.6 (4.00)

88.9 (3.50) 76.2 (3.00) 50.8 (2.00) .75" INLET PORT 2-117 O-RING BOSS .75" OUTLET PORT 2-117 O-RING BOSS 15.9 (.62) 31.7 (1.25) INDICATOR BSP 1/2 -14 25.4 (1.00)

IN
91.44 (3.60)

OUT

IN

31.7 (1.25) 33 (1.30)

79.2 (3.12)

DIMENSIONS mm (inches)
50.8 (2.00)

A HAND TIGHT BOWL ONLY

76.2 (3.00)

PF2/L4 PF2/L8

A 99.1 (3.90) 193.0 (7.60)

B Element Removal 90.0 (3.5) 184.0 (7.2)

9.40 (.37)

TBPF2-1004

For technical service call 317.849.3535 or fax 317.849.9201

www.filterelement.com