Anda di halaman 1dari 17

10L

CCH UX Series LED Exit Signs

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

NEMA 4X, IP66

The Cooper Crouse-Hinds CCH UX Series LED Exit Sign combines the strength and durability of die cast aluminum with architecturallypleasing aesthetics. The CCH UX Series is illuminated by LEDs, providing the customer with a long-life, low maintenance, dependable exit sign for use in conditions where reliability is crucial. Designed for the most severe environments, the CCH UX Series will provide maximum performance against rain, moisture, cold, corrosion, and dust in applications such as manufacturing plants, refineries, petrochemical and chemical plants, waste and sewage treatment facilities, food processing, and other industrial facilities.

Applications:
In locations deemed hazardous due to the presence of flammable vapors or gases In areas where the presence of gases or vapors may become present during an abnormal, unusual, or accidental conditions Outdoor and wet applications Where required by the National Electrical Code, Life Safety Code, or other applicable codes

Benefits of LED Technology:


Provides safe and reliable exit marking both indoors and outdoors during power failure or interruption of power to normal lighting system Long life (>50K hours) for years of maintenance-free operation Energy-efficient for lower cost of operation Low temperature operation with no loss of illumination Rugged and durable light source for the harshest of environments

Features and Benefits:


Wet location, outdoor rated for use in the most demanding environments Optional hazardous location rating available Dual voltage 120V/277V reduces wiring errors Heavy-duty nickel cadmium battery for long life 24-hour charge and recharge recovery time increases safety Heavy-duty injection molded polycarbonate lens protects against impact and corrosion Brown-out protection protects battery and reduces labor Heavy-duty aluminum die cast housing protects against impact and chemical resistance LEDs provide long life, even illumination, and energy savings Wide operating temperature range (-45C to 45C) Self-diagnostic testing reduces costs by eliminating scheduled equipment verification tests Heavy duty nickel cadmium battery for long life meets 90 minute requirements for battery operated emergency system

Temperature Performance Data:


CCH UX Series Exit Sign: -45C (-49F) to 45C (113F) CCH UX-HAZ Hazardous Location Exit Sign: T6 rating at 45C (113F)

Electrical Ratings:
Power Supply 120V/277V dual voltage LED Exits - Red Input Power 120V = 2.7W 277V = 3.2W Input Current: (Max.) 120V = .07A 277V = .04A LED Exits - Green Input Power 120V = 2.3W 277V = 3.0W Input Current: (Max.) 120V = .08A 277V = .03A

10L

Certifications and Compliances:


NEMA 4X, UL50 UL924 wet location IP65, IP66 Available with NEC hazardous location rating - UL844 Class I, Division 2, Groups A, B, C, D

Ordering Information:
Catalog Number CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH UX70RSDHAZ UX60RHAZ UX70GSDHAZ UX60GHAZ UX70RSD UX70RWHSD UX70RBKSD UX60R UX60RWH UX60RBK UX70GSD UX70GWHSD UX70GBKSD UX60G UX60GWH UX60GBK Housing Finish Silver Housing Silver Housing Silver Housing Silver Housing Silver Housing White Housing Black Housing Silver Housing White Housing Black Housing Silver Housing White Housing Black Housing Silver Housing White Housing Black Housing Letter Color Red LED Red LED Green LED Green LED Red LED Red LED Red LED Red LED Red LED Red LED Green LED Green LED Green LED Green LED Green LED Green LED

Dimensions
In Inches:

Mounting: wall mount, ceiling mount, end mount Conduit Entry: top, bottom, or either side of the unit 1162
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

CPMVFB Emergency Compact Fluorescent


Continuous Operation Champ-Pak Luminaires
Applications:
Where emergency lighting is required to permit workers in industrial areas to safely encounter their surroundings during power failures Where emergency egress lighting is required, such as: catwalks, walkways, tunnels, doorways, stairs, stairwells, ramps and aisles Indoor and outdoor wall mounting or vertical surface mounting where minimal luminaire depth is required in: Manufacturing plants and heavy industrial facilities Industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical, and platforms Waste or sewage treatment plants Offshore, dockside, and harbor installations For security and safety lighting in industrial facilites for lighting of loading docks, tunnels, and stairways For marine, wet location, hose down, and corrosive environments

Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Standard Materials:

Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence* Marine & Wet Locations 3, 3R, 4, 4X; IP66 Emergency Lighting

10L

Luminaire housing and door frame assembly copper-free aluminum External hardware stainless steel Lens heat- and impact-resistant refractor style glass Gaskets silicon rubber Reflector aluminum light sheet Wire guard stainless steel

Standard Finishes:
Aluminum Corro-free epoxy powder coat Stainless steel natural

Options:
Description Suffix Restricted breathing construction................................................................................. S826 Class I, Division 2 & Zone 2 suitability Cooler operating temperatures (T-numbers) Certified for IEC Zone 2 (Suffix S826TB)....................................................................... S826TB Furnished with: Terminal Block Crimp Terminals Dedicated voltage ballasts (no MT, DT or TT) Factory assembled with lamp installed......................................................................... FA Fused - projects ballast and capacitors against abnormal line conditions.................. S658 (Not for use in Canada) (Not for Marine use)

Features and Benefits:


Unique compact shallow profile design mounts virtually anywhere Side hinged cover with two screw closing for easy installation and maintenance Gray Corro-free epoxy powder coat two-piece housing provides superior corrosion resistance Unique stainless steel wire guard accessory attaches without any additional hardware for easy installation and maintenance Glass refractor provides uniform light distribution to eliminate glare Silicon gaskets make luminaire suitable for NEMA 4X, marine enviroments High power factor ballasts (+90%) are standard, which allow more luminaires per circuit

Electrical Rating Ranges:


52 watts 120277V, 5060 Hz 120V, 60 Hz 347V, 60 Hz

About the Battery:


Bodine fluorescent battery pack ballasts are UL component recognized Sealed, maintenance-free, high temperature nickel cadmium Solid state chargers are sealed inside the ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During auxiliary use 1 lamp has continuous operation A red indicator light indicates the battery is charging Wiring instructions for a "Push-to-Test" button is supplied with the fixture

10L

Certifications and Compliances:


NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 IEC: Zone 2 Ex nR IIC UL Standards: 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations CSA Standards: C22.2 No. 137 IEC Standards: 60079-15
*Consult Cooper Crouse-Hinds.

Accessories:
Description Stainless steel wire guard............................................................................................. Cat. # P55

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1155

10L

CPMVFB Emergency Compact Fluorescent


Continuous Operation Champ-Pak Luminaires

Ordering Information Dimensions & Weights

Ordering Information:
Hub Size
3

Lamp Watts 26

Cat. # for use with ANSI Lamps CPMVFB2W026

/4 NPT

Standard Voltage Ballasts


Voltage Suffix NEC/UL 120277V 5060 Hz /UNV CEC/CSA (cUL) 120V/60 Hz 347V 60 Hz /120CAN /347

Dimensions
In Inches:

10L

Net Weights:
Luminaire Less Guard P55 Guard 18.6 lbs. 0.5 lbs.

1156

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

DMVF(B) Exit Sign Fluorescent Luminaire

Cl. I, Div. 2; Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Certifications and Compliances:

Cl. II, Groups E, F, G, Cl. III & Simultaneous Presence Marine & Wet Locations 3, 3R, 4X; IP66

10L

Applications:
DMVF(B) Exit Signs are used: In any building or enclosed area where people work Where illuminated exit signs are required To provide distinct, highly visible exit markings To indicate the direction of travel to exits In locations deemed hazardous due to the presence of flammable vapors or gases, or combustible dusts

Features:
Six inch letters on white glass sign panel make the word "exit" stand out boldly and clearly Housings made of die-cast copper-free aluminum (less than 0.4 of 1% copper) for strength and resistance to corrosion Mounting module equipped with integral hub set-screws for vibration resistance (ceiling and pendant mounts) Hubs are provided with an integral conduit stop and bushing to help prevent damage to field wiring during installation Epoxy powder finish and stainless steel external hardware for resistance to corrosion Long life gaskets which provide seals between mounting module, housing, and globe assembly Grounding wire for safety Cool operating design Optional emergency battery back-up operation during power outage

NEC and CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 IEC: Zone 2 Ex nR IIC UL Standards: 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Luminaires CSA Standards: C22.2 No. 137 IEC Standards: 60079-15

Standard Materials:
Ballast housings and mountings copperfree aluminum (less than 0.4 of 1%) Exterior hardware stainless steel Globe heat- and impact-resistant internally fluted glass

Standard Finishes:
Aluminum gray epoxy powder coat Krydon material high reflectance white Stainless steel natural

Options:
Description Suffix Lamps supplied with exit sign............................................... S714 Top hat with stainless steel threaded insert.......................... S806 Restricted breathing construction.......................................... S826 Class I, Division 2 & Zone 2 suitability Cooler operating temperatures (T-Numbers) Certified for IEC Zone 2......................................................... S826TB Furnished with: Terminal Block Crimp Terminals Dedicated voltage ballasts (no MT, DT or TT)

About the Battery:


Bodine fluorescent battery pack ballasts are UL component recognized Sealed, maintenance-free, high temperature nickel cadmium Solid state chargers are sealed inside the ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During emergency use 1 lamp has continuous operation A red indicator light indicates the battery is charging Wiring instructions for a "Push-to-Test" button is supplied with the fixture

10L

Electrical Rating Ranges:


52 Watt 120277V, 5060 Hz 120V, 60 Hz 347V, 60 Hz

Ordering Information:
Mounting Type Pendant Supply Voltage Volts/Hertz 120277V / 5060 Hz 120V / 60 Hz (Canada) 347V / 60 Hz 120277V / 5060 Hz 120V / 60 Hz (Canada) 347V / 60 Hz 120277V / 5060 Hz 120V / 60 Hz (Canada) 347V / 60 Hz
US: 1-866-764-5454

Energy Savings:
Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output

Fluorescent Cat. # DMVF2A052G/UNV EXD DMVF2A052G/347 EXD DMVF2C052G/UNV EXD DMVF2C052G/347 EXD

Fluorescent with Battery Back-up Cat. # DMVFB2A052G/UNV EXD DMVFB2A052G/120CAN EXD DMVFB2A052G/347 EXD DMVFB2C052G/UNV EXD DMVFB2C052G/120CAN EXD DMVFB2C052G/347 EXD

Ceiling

Wall

DMVF2TW052G/UNV EXD DMVFB2TW052G/UNV EXD DMVFB2TW052G/120CAN EXD DMVF2TW052G/347 EXD DMVFB2TW052G/347 EXD
Copyright 2011 Cooper Crouse-Hinds

www.crouse-hinds.com

CAN: 1-800-265-0502

1149

DMVFB Emergency Compact Fluorescent


Continuous Operation Champ Luminaires
Applications:
DMVF Series Champ Lighting Luminaires are used: Where emergency lighting is required to permit workers in industrial areas to safely encounter their surroundings during power failures Where emergency egress lighting is required, such as: catwalks, walkways, tunnels, doorways, stairs, stairwells, ramps, and aisles In areas made hazardous by abnormal conditions resulting in the presence of flammable vapors or gases In areas made hazardous by the presence of combustible dusts Where combustible dusts and flammable vapors are present simultaneously In marine applications where water spray and corrosive atmospheres are considerations On installations where vibration and rough usage are problematic Where a cool, efficient light source is required In areas that require lamps to reach full illumination immediately In refineries, chemical and petrochemical facilities, grain processing, handling or storage facilities, manufacturing plants, wastewater treatment plants, sewage treatment plants, oil terminals, food processing facilities, breweries, and any other manufacturing or processing facility where safe, reliable hazardous area fluorescent or auxiliary lighting is needed

Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Certifications and Compliances:

Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence Marine & Wet Locations 3, 3R, 4, 4X; IP66 Emergency Lighting

10L

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 Emergency Lighting IEC: Zone 2 Ex nR IIC UL Standards: 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations 924 Emergency Lighting CSA Standards: C22.2 No. 137 IEC Standards: 60079-15

Standard Materials:
Ballast housings and mountings copperfree aluminum (less than 0.4 of 1%) External hardware guards stainless steel Reflectors Krydon fiberglassreinforced polyester material Globe heat- and impact-resistant internally fluted glass

Electrical Rating Ranges:


52, 64, and 84 watts 120277V, 5060 Hz 347V, 60 Hz

Standard Finishes:
Aluminum gray epoxy powder coat Krydon material high reflectance white Stainless steel natural

Accessories:
(Order separately) Description Dome 30 Angle Cat. # RD739 RA739

Standard Features:
Housings made of die-cast copper-free aluminum (less than 0.4 of 1% copper) for strength and resistance to corrosion Mounting modules equipped with integral hub set-screws for vibration resistance (ceiling, pendant, and quad mounts) Hubs are provided with an integral conduit stop and bushing to help prevent damage to field wiring during installation Epoxy powder finish and stainless steel external hardware for resistance to corrosion Long-life gaskets which provide seals between mounting module, housing, and optical assembly Grounding wire for safety Cool operating design Optional stainless steel open bottom guard permits direct access to the globe for easy relamping Battery pack ballast for emergency lighting

10L

Options:
Description Suffix Restricted breathing construction................................ S826 -Class I, Division 2 & Zone 2 suitability -Cooler operating temperatures (T-numbers) Certified for IEC Zone 2............. S826TB -Furnished with: Terminal Block Crimp Terminals Emergency operation only Consult Cooper-Hinds Factory assembled with lamp installed....................................... FA Fused to protect ballast against abnormal line conditions (not for use in Canada) (not for marine use).................................. S658 Lamps supplied with luminaire... S714 Top hat with stainless steel threaded insert to attach ballast housing........................................ S806 TEFLON coating on globe for increased shatter protection....... S808

Energy Savings
Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output

About the Battery (DMVFB Units):


Bodine fluorescent battery pack ballasts are UL component recognized Sealed, maintenance-free, high temperature nickel cadmium Solid state chargers are sealed inside the ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During auxiliary use 1 lamp has continuous operation A red indicator light indicates the battery is charging Wiring instructions for a "Push-to-Test" button is supplied with the fixture

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1157

10L

DMVFB Emergency Compact Fluorescent


Continuous Operation Champ Luminaires

Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB)
DMVFB Series Fluorescent with Battery Back-Up with G303 Globe and P33 Guard Cat. # DMVFB2A052GP DMVFB3A052GP DMVFB2A064GP DMVFB3A064GP DMVFB2A084GP DMVFB3A084GP

Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence Marine & Wet Locations 3, 3R, 4, 4X; IP66 Emergency Lighting

Mounting Style Pendant Mount

Hub Lamp Size (In.) Watts /4 1 3 /4 1 3 /4 1


3

52 64 84

Flexible Pendant Mount

/4 /4 3 /4
3 3

52 64 84

DMVFB2HA052GP DMVFB2HA064GP DMVFB2HA084GP

Ceiling Mount Thru-Feed

/4 1 3 /4 1 3 /4 1
3

52 64 84

DMVFB2C052GP DMVFB3C052GP DMVFB2C064GP DMVFB3C064GP DMVFB2C084GP DMVFB3C084GP

Wall Mount Thru-Feed

/4 1 3 /4 1 3 /4 1
3

52 64 84

DMVFB2TW052GP DMVFB3TW052GP DMVFB2TW064GP DMVFB3TW064GP DMVFB2TW084GP DMVFB3TW084GP

Note: For technical information on family trees, temperature performance data, dimensions, weights, and photometrics, refer to Series in Section 6L.

10L

Quad-Mount Pendant, Adjustable Thru-Feed, 25 Angle, 121/ 2 Angle

/4 /4 3 /4
3 3

52 64 84

DMVFB25Q052GP DMVFB25Q064GP DMVFB25Q084GP

Stanchion Mount 25 Angle

11/2 11/2 11/2

52 64 84

DMVFBJ052GP DMVFBJ064GP DMVFBJ084GP

Stanchion Mount Straight

11/ 2 11/ 2 11/ 2

52 64 84

DMVFBP052GP DMVFBP064GP DMVFBP084GP

1. Catalog numbers are basic numbers. Voltage must be specified. Standard Voltage Ballasts NEC/UL 1. Voltage Suffix 120277V 5060 Hz /UNV 120V/60 Hz /120CAN CEC/CSA (cUL) 347V 60 Hz /347

1158

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

10L

EVLPF(B) Exit Sign Fluorescent Luminaire

Cl. I, Div. 1, Groups B (suffix GB), C, D Cl. I, Zone 1, Groups IIB + H2 (GB suffix), IIB Cl. II, Div. 1, Groups E, F, G; Class III, Simultaneous Presence

Marine & Wet Locations 3, 3R, 4, 4X; IP66

Applications:
EVLPF(B)-EXD Exit Signs are used: In any building or enclosed area where people work where illuminated exit signs are required To provide distinct, highly visible exit marking To indicate the direction of travel to exits In locations deemed hazardous due to the presence of flammable vapors, gases, or combustible dusts

Certifications and Compliances:


NEC and CEC: Class I, Division 1, Groups B (GB suffix), C, D Class I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Class II, Class III & Simultaneous Presence (Class I and Class II) UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations CSA Standards: C22.2 No. 137

Features and Benefits:


Six inch red letters on white glass sign panel make the word "EXIT" stand out boldly and clearly Lightweight copper-free aluminum housing with powdered epoxy finish All exterior hardware is corrosionresistant stainless steel Three mounting arrangements: pendant, ceiling, and wall bracket Integral ballast High power factor (90%+) ballasts Easier assembly, installation, and maintenance Outdoor, hose down, marine and corrosive environments suitable Ideal for adverse environments typical of industrial facilities Ground wire for safety Optional battery back-up for operation during power outage

Ratings (Electrical/Size):
Sources/wattage: 52W (2-26W lamps) 120-277V, 50-60 Hz 120V, 60 Hz 347V, 60 Hz Conduit entries: 3/4", 1" NPT pendant, wall bracket, ceiling

Standard Materials:
Mounting modules, cover, ballast housing, globe holder copper-free aluminum Globe heat- and impact-resistant glass Exterior hardware stainless steel

Standard Finishes:
Copper-free aluminum Corro-free powdered epoxy

Options:
Description Group B suitability Factory assembled with lamps Suffix GB FA

About the Battery:


Bodine fluorescent battery pack ballasts are UL component recognized Sealed, maintenance-free, high temperature nickel cadmium Solid state chargers are sealed inside the ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During emergency use 1 lamp has continuous operation Red indicator light indicates the battery is charging Wiring instructions for a "Push-to-Test" button is supplied with the luminaire

10L

Ordering Information:
Supply Mounting Voltage Type Volts/Hertz Pendant Fluorescent Cat. # Fluorescent with Battery Back-up Cat. #

120277V / 5060 Hz EVLPFA02520/UNV EXD EVLPFBA02520/UNV EXD 120V / 60 Hz (Canada) EVLPFBA02520/120CAN EXD 347V / 60 Hz EVLPFA02520/347 EXD EVLPFBA02520/347 EXD 120277V / 5060 Hz EVLPFCX02520/UNV EXD EVLPFBCX02520/UNV EXD 120V / 60 Hz (Canada) EVLPFBCX02520/120CAN EXD 347V / 60 Hz EVLPFCX02520/347 EXD EVLPFBCX02520/347 EXD 120277V / 5060 Hz EVLPFBX02520/UNV EXD EVLPFBBX02520/UNV EXD 120V / 60 Hz (Canada) EVLPFBBX02520/120CAN EXD 347V / 60 Hz EVLPFBX02520/347 EXD EVLPFBBX02520/347 EXD

Ceiling

Wall

Energy Savings:
Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output

1148

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

EVLPFB Emergency Compact Fluorescent


Continuous Operation Low Profile Luminaires
Applications:
Cooper Crouse-Hinds Low Profile HazardGard Luminaires are used in: Areas that require lamps to reach full lumination immediately Where emergency lighting is required to permit workers in industrial areas to safely encounter their surroundings during power failures Where emergency lighting is required such as: catwalks, walkways, tunnels, doorways, stairs, stairwells, ramps, and aisles Areas where flammable or explosive vapors or gases are present Hazardous areas, both indoors and outdoors, where long life and low maintenance costs are desired Petroleum refineries, chemical, petrochemical and pharmaceutical plants, oil terminals, gas plants and other heavy process industry facilities Waste treatment facilities Drilling platforms and other coastal and offshore hazardous areas

Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G; Class III, Simultaneous Presence

Marine & Wet Locations 3, 3R, 4, 4X; IP66 Emergency Lighting

10L

Standard Materials:
Mounting modules, cover, ballast housing, globe holder copper-free aluminum Globe heat- and impact-resistant glass Exterior hardware stainless steel Reflectors (dome & angle) Krydon fiberglass-reinforced polyester

Ratings (Electrical/Size):
Sources/Wattage: Fluorescent continuous operation emergency lighting 52W (2-26W lamps) and 64W (2-32W lamps) compact fluorescent voltages Fluorescent emergency lighting 120277V, 5060 Hz 120V, 60 Hz 347V 60Hz Conduit entries: 3/4", 1" NPT pendant, wall bracket, ceiling 11/4" NPT stanchion

Features and Benefits:


Small, compact size Two start Acme threaded construction Easier assembly, installation, and maintenance Lightweight copper-free aluminum housing with powdered epoxy finish All exterior hardware is corrosionresistant stainless steel Four mounting arrangements: pendant, ceiling, wall bracket, and stanchion Integral ballast High power factor (90%+) ballasts Uses same mounting modules as the standard HazardGard Internally fluted glass globes Krydon construction dome and angle reflectors won't rust, corrode, dent, chip, or peel Now available in components luminaire body, mounting module, guard, reflectors Three wire construction For energy conservation, luminaires can be switched off without affecting the emergency operation feature

Standard Finishes:
Copper-free aluminum Corro-free powdered epoxy Krydon white Stainless steel guard

Energy Savings
Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output

Options:
Description Group B suitability Fused (not for use in Canada) (not for marine use) Factory assembled with lamps Emergency operation only Consult Cooper Crouse-Hinds Suffix GB S658* FA

10L

*When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number.

Accessories:
Description Dome reflector Angle reflector Cat. # RD739 RA739

Certifications and Compliances:


NEC/CEC: Class I, Division 1, Groups B (with GB suffix), C, D Class I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Class II, Class III & Simultaneous Presence (Class I and Class II) Emergency Lighting UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations 924 Emergency Lighting CSA Standards: C22.2 No. 137

About the Battery:


Bodine fluorescent battery pack ballasts are UL component recognized Sealed, maintenance-free, high temperature nickel cadmium Solid state chargers are sealed inside the ballast case; 90 minute illumination time; 10-year life expectancy 2-year warranty During emergency use, 1 lamp has continuous operation A red indicator light indicates the battery is charging Wiring instructions for a "Push-to-Test" button is supplied with the fixture

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1159

10L

EVLPFB Emergency Compact Fluorescent


Continuous Operation Low Profile Luminaires

Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G; Class III, Simultaneous Presence

Marine & Wet Locations 3, 3R, 4, 4X; IP66 Emergency Lighting

Ordering Information:

Pendant Mount

Pendant Wall Bracket Hub Size With Guard With Guard Watt (In.) Cat. # Cat. # Fluorescent with Emergency Ballast High Power 3 /4 EVLPFBA02521 EVLPFBBX02521 EVLPFBA03521 EVLPFBBX03521 52W 1 11/4 64W
3 /4 1 11/4

Ceiling

Stanchion

Luminaire Body Less Mounting Module & Guard

With Guard With Guard Cat. # Cat. # Factor Ballast (Min. P.F. 90%) EVLPFBCX02521 EVLPFBCX03521 EVLPFBJ04521 EVLPFBCX02641 EVLPFBCX03641 EVLPFBJ04641

Cat. # EVLPFB0520

EVLPFBA02641 EVLPFBA03641

EVLPFBBX02641 EVLPFBBX03641

EVLPFB0640

Complete Catalog Numbers as follows:


Standard Voltage Ballasts
NEC/UL 1. Voltage Suffix 120277V 5060 Hz /UNV 120V/60 Hz /120CAN CEC/CSA (cUL) 347V 60 Hz /347

2.

Example: EVLPFB02521/UNV Other Voltages Consult Cooper Crouse-Hinds

Wall Bracket Mount

Note: For technical information on family trees, temperature performance data, dimensions, weights, and photometrics, refer to DMVF Series in Section 6L.

EVFPFB Fluorescent Emergency Lighting


Three wire construction, for switching purposes, is standard on fluorescent emergency lighting. For energy conservation, luminaires can be switched off without affecting the emergency operation feature.

10L

Ceiling Mount

*Test switch is remote mounted. Use Cooper Crouse-Hinds EDSC218 (Not furnished).

Stanchion Mount
Ceiling and bracket mounts have 4 hubs: 3 are plugged.

1160

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

10L

EXL Explosionproof Exit Sign


Factory-sealed

Cl. I, Div. 1 & 2, Groups C, D Cl. I, Zone 1 IIB Cl. II, Div. 1, Groups E, F, G

Applications:
EXL Exit Signs are used: In locations deemed hazardous due to the presence of flammable vapors or gases, or combustible dusts In any building or enclosed area where people work where illuminated exit signs are required To provide distinct, highly visible exit marking To indicate the direction of travel to exits

Ordering Information:
When ordering an EXL Series Exit Sign, you will need to specify: (A) Voltage (120VAC or 120VDC) (B) Mounting (Wall, End Bracket, or Pendant) (C) Exit Sign Designation All units come standard with 3/4" hubs and exit signs with red lettering and white background. Complete catalog numbering is as follows: EXL (A) 2 (B) (C) (A) Voltage: 120VAC ............ leave blank 120VDC .......................... D (B) Mounting: Wall................................. 1 End Bracket.................... 2 Pendant .......................... 3 (C) Exit Sign Designation: A Single Face (Wall Mount) AA Double Face (End Bracket & Pendant) AB Double Face, one side arrowhead right, the other no arrowhead (End Bracket & Pendant) AC Double Face, one side arrowhead left, the other no arrowheads (End Bracket & Pendant) AD Double Face, one side arrowhead both ends, the other no arrowheads (End Bracket & Pendant) B Single Face, arrowhead right (Wall Mount) BC Double Face, one side arrowhead right, the other arrowhead left (End Bracket & Pendant) BD Double Face, one side arrowhead both ends, the other arrowhead right (End Bracket & Pendant) C Single Face, arrowhead left (Wall Mount) CD Double Face, one side arrowhead both ends, the other arrowhead left (End Bracket & Pendant) D Single Face, arrowhead both ends (Wall Mount) DD Double Face, both sides arrowhead both ends (End Bracket & Pendant) Mounting Type Wall End Bracket Pendant Sign Panel Description Single face Double face Double face Hub Size (In.)
3 3 3

Features:
Two incandescent lamps (not included) wired in parallel to provide extra margin of light source reliability Solid state circuit for extended lamp life in AC units Six inch red letters on white acrylic sign panel make word "exit" stand out boldly and clearly Edge lighting characteristic of sign panel makes visibility excellent at all lighting levels Factory-sealed explosionproof housing Pendant, wall, and end bracket mounts provide universal installation options Impact-resistant acrylic sign panel needs no guard makes cleaning easy Internal rectifier extends lamp life beyond 1,000-hour rated life reduces relamping cost Relamping tool provided

Pendant Style

End Bracket Style

Certifications and Compliances:


NEC: Class I, Groups C, D Class II, Groups E, F, G UL Standard: 844 NFPA Life Safety Code No. 101-1991

10L

Standard Materials:
Body copper-free aluminum Sign panel acrylic

Conduit Entrance:
3/4" hubs

Lamp Wattage:
Two 60 watt, 60T10 clear lamps for AC units Two 25 watt, 25T10 clear lamps for DC units Lamps not included with luminaire

Wall Style AC Cat. # EXL21A EXL22AA EXL23AA DC Cat. # EXLD21A EXLD22AA EXLD23AA

Electrical Ratings:
120VDC or 120VAC operation

/4 /4 /4

Temperature Performance Data:


(for both AC & DC operation):
Ambient Temp. (C) 25 40 1146 Class I (C, D) Class II (E, F, G) T3C T3C Supply Wire C 150C

Options:
Description Suffix Exit signs with green lettering on white background........................................................ GN Unit provided with epoxy powder coat............................................................................. S752 277VAC (Order ECT413 Transformer Separately)

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

EXL Explosionproof Exit Sign


Factory-sealed Dimensions
Dimensions
In Inches:

10L

Pendant Style

Wall Style

10L

End Bracket Style

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1147

Ex-Lite LED Exit Signs

Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, AEx em ib IIC (NEC) Cl. I, Zone 1, Ex em ib IIC (CEC) Cl. II, Div. 2, Groups F, G (NEC) Cl. II, Div. 2, Groups E, F, G (CEC)

UL Listed IP66

10L

The Ex-Lite Series of LED exit signs are designed for hazardous locations and are ideally suited for marking escape routes and exits in potentially explosive atmospheres. The Ex-Lite Z is available as an AC only version, while the Ex-Lite ZE is available with self-contained battery. As an emergency lighting luminaire with selfcontained battery system, the Ex-Lite ZE features a nickel cadmium battery with automatic test and monitoring feature.

Applications:
In harsh and hazardous environments where illuminated exit signs are required

Features and Benefits:


LED Technology: Long life (>50K hours) for years of maintenance-free operation Energy-efficient for lower cost of operation Low temperature operation with no loss of illumination Rugged and durable light source for the harshest of environments Exit Sign System: Can be used in a hazardous location Conduit or cable entry Can be installed in moist, humid, rain, and wet environments Universal input voltage 110VAC-277VAC and 110VDC-250VDC reduces inventory Ex-Lite ZE with self-monitoring, selfdiagnostic, and test capability Premium heavy-duty nickel cadmium battery 24-hour charge and recharge time increases safety by recovering quickly from outage "EXIT" legend with alternative wings left, right, or left and right; simple field modification Emergency lighting cycle three hours The housing of the luminaire is constructed with a corrosion resistant, robust, lightweight aluminum alloy material and illumination of the sign is provided with red, high-efficient LEDs

Ordering Information:
Catalog Number Material Number Description Light Source Life of LED Rated Voltage, VAC Frequency, Hz Rated Voltage, DC Power Consumption Battery Allowable Temperature Range Mounting Cable Entry Conduit Entry Protection Ex Lite Z 12191001005 AC/DC Exit Sign LED 50K hours 120V-277V 50/60 110V-250V 6VA N/A -4F to 122F (-20C to 50C) Wall Ex-e 3 /4" IP66 Ex Lite ZE 12191130005 with Battery LED 50K hours 120V-277V 50/60 110V-250V 6VA NiCad 41F to 95F (5C to 35C)* Wall Ex-e 3 /4" IP66

10L

*Due to battery chemistry, the charging capacity will be limited at temperatures below 5C and above 35C.

Dimensions
In (mm):

Certifications and Compliances:


Class I, Division 2, Groups A, B, C, D Class I, Zone 1, AEx em ib IIC (NEC) Class I, Zone 1, Ex em ib IIC (CEC) Class II, Division 2, Groups F, G (NEC) Class II, Division 2, Groups E, F, G (CEC) IP66 UL844 UL924/CSA22.2 No. 141-02 UL60079/CSA22.2 E60079 UL1203/CSA22.2 E6124-1-1-02
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2012 Cooper Crouse-Hinds

1161

10L

ELPS Light-Pak Emergency Lighting System

Cl. I, Div. 1 & 2, Groups C, D Cl. I, Div. 1 & 2, Groups B, C, D (with suffix GB) Cl. II, Div. 1, Groups E, F, G Cl. III

Cl. I, Zone 1 Simultaneous Presence Wet Locations NEMA 3, 3R, 12

Applications:
ELPS Series Emergency Lighting Systems are used: To provide safe, reliable illumination indoors or outdoors to designated areas during failure or interruption of power to the normal lighting system In areas made hazardous by the presence of flammable gases and vapors, combustible dusts, or easily ignitible fibers and flyings In areas where corrosion, vibration, moisture, dirt, and rough usage may be encountered Where required by the National Electrical Code, the Life Safety Code, or other codes In refineries, chemical and petrochemical facilities, grain processing, handling or storage facilities, manufacturing plants, wastewater treatment facilities, and other areas where safe, reliable, hazardous area emergency lighting is needed

CID 101 corrosion inhibitor device is provided with each ELPS system to help protect electrical components and connections Rugged, long-life, maintenance-free, nickel cadmium battery provides 30 watts of power for the required 11/2 hours Solid state battery charger for long life and reliable service prevents deep discharge by automatically disconnecting luminaires from battery Terminal block facilitates field wiring connections Instruction sheet and maintenance record card provided with unit in a protective plastic envelope A time delay is standard; time delay is preset at factory for 5 minute delay but can be field set for 5 seconds or 15 minutes, thus allowing HID type lamps time to restrike and reach desired illumination levels Solid state battery charger will accept 120, 220/240 or 277 VAC, 50/60 Hz

Electrical Ratings:
Power Supply: Input: 120, 220/240, 277 VAC, 50 or 60 Hz 0.5 Amps Maximum Output: 12 VDC UL listed for 28 watts for 11/2 hours at 0 40C Luminaires: Voltage: 12 VDC Lamp Type: #789, miniature Tungsten halogen, G4, 2-pin, 14 watt

Features:
Compact factory-sealed luminaire assemblies are each furnished with a 12 watt tungsten-halogen lamp and inner reflector for appropriate photometrics in hazardous areas Luminaire assemblies are fully adjustable and lockable on two axes to provide flexible and consistent light aiming capabilities Luminaire lens ring is threaded for easy relamping and locks in place with hex head set-screw; will not loosen due to vibration Ground joint cover with external flange design permits large opening and easy access to internal components; stud bolts in diagonally opposite corners of body ease cover removal and installation Neoprene cover gasket seals out moisture for superior protection of internal components against wetness and corrosion Lightweight, compact size, and mounting feet ease installation and allow placement in confined areas Two 1" NPT drilled and tapped conduit openings, with plugs, are standard, for choice of top or bottom feed Factory-installed PUSH-TO-TEST pushbutton enables easy testing of system MAIN POWER ON pilot light indicates AC power is being supplied to the battery charger; pilot light jewel is threaded for easy lamp replacement Stainless steel drain minimizes moisture collection; stainless steel breather with aluminum cap provides ventilation, minimizes moisture collection

Certifications and Compliances:


NEC: Class I, Groups B, C, D Class II, Groups E, F, G Class III Simultaneous Presence NEMA: 3R, 12 (ELPS power supply) Suitable for wet locations (EVLA fixtures) Marine (EVLA fixtures) UL Standard: 844 Electric Luminaire Hazardous Locations 924 Emergency Lighting and Power Equipment 1203 Explosionproof and DustIgnitionproof Electrical Equipment Life Safety Code: Section 5-9 (Emergency Lighting) Suitable for Wet Locations NEMA 3, 3R, 12 Marine

Options:
Description Suffix Remote mounted lamp head and arm .... EVLA12 Key operated disconnect switch as part of the ELPS502 emergency light system .......................... S794 Keyless operated designated disconnect switch as part of the ELPS502 emergency light system .......... S854

Ordering Information:
Description Cat. # Standard unit with ELPS502 adjustable heads............ Replacement power interior, includes circuit ELPS K50 board and battery pack Power supply ................. ELPS50 Lamphead and arm ....... EVLA12 Exit sign, double sided ELPS502 EXD with EVI, red letters........ Exit sign, double sided ELPS502 EXD GN with EVI, green letters.... Exit sign, single or double sided with Group B EVA, ELPS502 EXD GB red letters....................... Exit sign, single or double sided with Group B EVA, green letters ............................. ELPS502 EXD GB GN Exit sign, single sided with EVI, red letters........ ELPS502 EXS Exit sign, single sided with EVI, green letters ................... ELPS502 EXS GN

10L

Standard Materials:
Power supply enclosure and luminaire assembly copper-free aluminum (less than 0.4 of 1% copper)

Standard Finishes:
Power supply enclosure and fixture assemblies powder coat epoxy paint finish

Base unit comes standard with Class I, Division 1, Group B.

1150

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

ELPS Light-Pak Emergency Lighting System

Temperature Performance Data Photometric Data Dimensions and Weights

10L

Temperature Performance Data:


Cat. # Class Maximum Ambient Temperature 55C I II* EVLA12 III* Maximum Ambient Temperature 40C ELPS EVI ELPS EVA T3C T4 T3C T4 T-number T4A T3B T3B

Photometric Data:

*For Class II and Class III applications, fixtures must not be aimed more than 30 above horizontal (see diagram below).

Dimensions
In Inches:

10L

Unit Net Weights:


ELPS502 complete emergency lighting system 50 lbs. ELPS50 power supply 40 lbs. EVLA12 luminaire assembly 5 lbs.

Status Indication:
LED Status Condition No light Steady light (no blinking) Light blinks once Light blinks twice Light blinks three times Light blinks four times Meaning of the Indication AC power is removed from the circuit Fully charged Charging Battery failure Circuit failure Lamp failure

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1151

10L

LED N2LPS LIGHT-PAK Emergency Lighting System

Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Wet Locations, Marine NEMA 3, 3R, 4X Ambient 0C to 55C

Applications:
LED N2LPS Light-Pak emergency lighting systems are used: To provide reliable illumination for egress areas during failure or interruption of power to the normal lighting system In areas where flammable gases or vapors may become present due to abnormal, unusual, or accidental conditions In manufacturing plants, refineries, petrochemical and chemical plants, waste and sewage treatment facilities, oil terminals, food processing facilities, breweries, and other industrial manufacturing or process industry facilities subject to wet or corrosive conditions To illuminate machinery or panels during a loss of AC power Where moisture, dirt, dust, or corrosion will limit the life and reliability of ordinary emergency lighting systems Where required by the National Electrical Code, the Life Safety Code or other applicable codes Outdoor applications

Certifications and Compliances:


NEC/CEC: Class I, Division 2, Groups B, C, D, Zone 2 UL Standards: 1598A (Supplemental Requirements for Luminaires for Installation on Marine Vessels) 924 (Emergency Lighting and Power Equipment) 844 (Electric Luminaires Hazardous Locations) CSA Standards: C22.2 No. 141-M1985 unit equipment for emergency lighting C22.2 No. 137-M1981 non-incendive electrical equipment for use in Class I, Division 2 hazardous locations Life Safety Code NFPA101 Section 5-9 (Emergency Lighting) Marine wet locations suitability, Type 4X

Electrical Ratings:
Power supply Input: 120, 220, 230, 240, or 277 VAC, 50 or 60 Hz; 28 watts max. Output: 12 VDC Luminaire heads Voltage: 12 VDC; Lamp: 3 watt LED Total lumen output: 80

Standard Materials:
Power supply and remote luminaire enclosures Krydon fiberglassreinforced polyester LED lamp head assembly epoxy powder coated stainless steel Exterior hardware nylon, plastic coated, and stainless steel Cover gasket Hypalon synthetic rubber

Features:
Compact, factory-assembled luminaire featuring LED lamps for improved lumen performance, on-time, and lamp life Nonmetallic, enclosed, and gasketed housing provides corrosion protection in the most extreme environments Durable and marine rated LED lamp head assemblies provide protection against water ingress, corrosion, and impact High temperature rated nickel cadmium battery for reliable operation up to 55C ambient Solid state battery charger for long life and reliable battery operation prevents deep discharge by automatically disconnecting the battery from the luminaire Factory-installed "push-to-test" button Self-test, monitoring, and diagnostics reduce costly maintenance checks Remote luminaire head assemblies (one or two) are available for mounting of luminaire heads away from main power system Stainless steel drain minimizes moisture collection Standard battery disconnect switch (Krydon unit)

Unit Net Weights:


N2LPS12222 16 lbs. N2LPS12220 12 lbs. N2RF1221 8 lbs. N2RF1222 9 lbs.

Temperature Performance Data:


Based on 55C ambient Cat. # Class I, Division 2 N2LPS (all) N2RF (all)
Note:

10L

40C - T5; 55C - T4A T5

Note:

Ambient temperature at which the Light-Pak system is rated is 0C to 55C. Operation at temperatures outside this range will affect the battery life and/or charging performance. Battery time in emergency mode is 90 minutes.

National Electrical Code and Life Safety Code are registered trademarks of the National Fire Protection Association, Inc. Noryl is a registered trademark of General Electric Company.

1152

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

LED N2LPS LIGHT-PAK Emergency Lighting System

Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Wet Locations, Marine NEMA 3, 3R, 4X Ambient 0C to 55C

10L

Ordering Information:
Description 28 watt, 12 volt power supply assembly with two 3 watt LED lamp heads 28 watt, 12 volt stainless steel power supply assembly with two 3 watt LED lamp heads 28 watt, 12 volt power supply assembly less luminaire heads Remote luminaire assembly with one 3 watt LED lamp head Remote luminaire assembly with two 3 watt LED lamp heads 28 watt, 120V LED Light-Pak with single sided exit sign** 28 watt, 277V LED Light-Pak with single sided exit sign** 28 watt, 120V LED Light-Pak with double sided exit sign** 28 watt, 277V LED Light-Pak with double sided exit sign**
*Not cUL approved. UL Listed only. **Exit sign operates in both normal and emergency mode.

Cat. # N2LPS12222 N2LPS12222 SS N2LPS12220* N2RF1221* N2RF1222* N2LPS12222/120 N2LPS12222/277 N2LPS12222/120 N2LPS12222/277

EXS DR0391734 EXS DR0391734 EXD DR0391734 EXD DR0391734

Note: Up to four (4) remote LED lamp assemblies can be connected to the N2LPS12222. Up to six (6) remote LED lamp assemblies can be connected to the N2LPS12220.

Wire Sizing for Remote Installation:


For Copper Wire
Running Distance (ft.) Between Power Supply and Remote Luminaire Load In Watts Wire Size 16 AWG 14 AWG 12 AWG 8 26 42 66 16 13 21 33 24 6 10 16 32 3 5 8 Wire Size 10 AWG 8 AWG 6 AWG Load In Watts 8 106 168 270 16 53 84 135 24 26 42 67 32 13 21 33

Maximum distance to limit line voltage drop to 5%.

Dimensions (N2LPS):
1.1

13.5

10L

16.0 5.0

7.5

7.4

13.8 14.5 18.0

Standard N2LPS LED Light-Pak

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1153

10L

LED N2LPS LIGHT-PAK Emergency Lighting System

Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Wet Locations, Marine NEMA 3, 3R, 4X Ambient 0C to 55C

Dimensions (N2LPS):

EXS, EXD Option N2LPS LED Light-Pak with Optional Emergency Exit Luminaire

Dimensions (N2RF):

9.50 9.50

10L

3.83

3.83

7.27

4.38

11.77

Detail Indication Logic:


Status Indication * *-* **-** ***-*** Status Description No Light Steady Light (No Blinks) Light Blinks Once Light Blinks Twice Light Blinks Three Times Status Definition AC Power Removed from Circuit Fully Charged Battery Charging Battery Failure Circuit Failure

1154

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds