Technical Documentation
Product family Tellabs

6300 Managed
Transport System
Product name Tellabs

6325 Edge Node


Document Configuration and Ordering Guide
MA364 / Revision D2
2 MA364 Rev. D2
Tellabs

6325 Edge Node Legal Notices


Legal Notices
Copyright Statement This Tellabs manual is owned by Tellabs or its licensors and protected by U.S.
and international copyright laws, conventions, and treaties. Your right to use
this manual is subject to limitations and restrictions imposed by applicable li-
censes and copyright laws. Unauthorized reproduction, modification, distri-
bution, display or other use of this manual may result in criminal and civil
penalties.
Trademark Notice The following trademarks and service marks are owned by Tellabs Opera-
tions, Inc., or its affiliates in the United States and/or other countries: AUDIO
PLUS

, CABLESPAN

, CEC-128, DYNAMIC SIGNAL TRANSFER,


DXX

, DXX logo

, EC DUO

, ENHANCED AUDIO PLUS

, EX-
PRESS/PATH

, FOCUS, MARTIS

, MARTISDXX

, MARTIS logo

, MAR-
TISDXX logo

, METROVANTAGE

, METROWATCH, NETREACH

,
NETWISE

, SCULPTURED SOUND, TELLABS

, TELLABS and T sym-


bol

, T symbol, TELLABS PROPARTNER, TEL/MAP, TEL/MOR

, THE
WORLD COMMUNICATES THROUGH TELLABS, TITAN

, VERITY,
YOUR NETWORKING PARTNER

.
Any other company or product names may be trademarks of their respective
companies.
MA364 Rev. D2 3
Tellabs

6325 Edge Node Environmental Notices


Environmental Notices
Instructions for use,
maintenance and
management of residual
product
The equipment covered in this manual has been designed to fulfil the environ-
mental demands of market and society. There are no apparent hazards during
use and on-site maintenance of the equipment. We recommend that repair of
defective equipment takes place at Tellabs premises, and it is likewise recom-
mended to dispose of the equipment by use of certified local waste contractors
that can assure environmental safe handling and disposal of the equipment.
Arrangement for disposal of equipment can also be made through Tellabs.
Waste handling in
member states of the
European Union
The equipment covered in this manual must be disposed of in accordance
with "Directive 2002/96/EC of the European Parliament and of the council of
27 January 2003 on waste electrical and electronic equipment (WEEE)".
Disposal must follow national legislation for "IT and telecommunications
equipment" in accordance with the WEEE directive.
Do not dispose of waste electrical and electronic equipment with unsorted
municipal and household waste
Collect the equipment separately
Return the equipment through the collection system agreed with Tellabs.
Correct handling of the disposed equipment contributes to reuse, recycling
and other form of recovery to protect the environment.
Label The equipment is marked with the figure shown below, to indicate that the
equipment must be collected separately. In case of very small products, the
figure may only be on the packaging or in this manual. The Tellabs name and
the production date will also be labelled on the product.
Further information For further information about separation and handling the disposed equip-
ment to ensure correct reuse or recycling, please look at www.tellabs.com.
4 MA364 Rev. D2
Tellabs

6325 Edge Node Revision Information


Revision Information
Revision history This guide has changed as follows:
Rev. Date Description of Changes
A1 Nov. 11, 2005 First version of the guide
A2 Feb. 28, 2006 Compared to revision A1:
120/75 ohm balun items for PIM1 module add-
ed. The balun provides 75 ohm E1 interface.
The name of the DC power supply module,
DC/DC converter, changed to PS-DC.
Ethernet cables added.
Minor changes have been performed.
B1 July 14, 2006 Compared to revision A2:
SPIMX module with 21 x 2 Mbit/s interfaces
added.
EMAP and ETEX10S modules added.
PS-DC module CM3561 (75 W) replaced by
CM3561-A (85 W).
Balun panel kit BNC added.
Minor changes have been performed.
B2 March 13, 2007 Compared to revision B1:
Tellabs 6325 node - Dedicated units added.
Pre-configured Tellabs 6325 node basic units
added.
Minor changes have been performed.
C1 Oct. 25, 2007 Compared to revision B2:
The following SDH/PDH modules added:
SPIMXm, SPIMX16m and PIM3P.
The following WDM modules added: OM-C,
OM-D, OAD1-C, OAD1-D, TR4 and MP4.
Various transceivers of type Ethernet, WDM,
bi-directional and Fibre Channel added.
Minor changes have been performed.
C2 Dec. 12, 2007 Compared to revision C1:
Cable WK-503Y-zz.z-11 replaced by WK-503Y-
zz.z-12.
Minor changes have been performed.
MA364 Rev. D2 5
Tellabs

6325 Edge Node Revision Information


D1 May 14, 2008 Compared to revision C2:
SIMX4 module replaced by SIMX4m module.
SIMX16 module replaced by SIMX16m module.
Transceiver TR-0028-xxx removed. In SDH
DWDM applications transceiver TR-0018-xxx
should be used.
Minor changes have been performed.
D2 Nov. 14, 2008 Compared to revision D1:
Balun WK-508B-01.0-01 removed.
Cable WK-504Y-zz.z-01 replaced by WK-504Y-
zz.z-10.
Cable WK-502X-03.0-01 replaced by WK-502Y-
03.0-01.
Transceivers TR-0024-xxx removed.
Minor changes have been performed.
Rev. Date Description of Changes
6 MA364 Rev. D2
Tellabs

6325 Edge Node Revision Information


Tellabs

6325 Edge Node Contents


MA364 Rev. D2 7
Legal Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Environmental Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Revision Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1 Configuration Guide for Tellabs 6325 Node . . . . . . . . . . . . . . . . . . 11
1.1 Tellabs 6325 Node Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.2 Configuring a Tellabs 6325 Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.3 Configuring a Tellabs 6325 Node by Selecting a Dedicated Unit . . . . . 14
1.4 Configuring a Tellabs 6325 Node by Selecting a Basic Unit . . . . . . . . 15
1.5 Configuring a Tellabs 6325 Node by Selecting Subrack and Modules 17
1.5.1 Selecting the Subrack and Support Modules for the Tellabs 6325
Node 18
1.5.2 Selecting the Traffic Modules for the Tellabs 6325 Node - SDH
Configurations 20
1.5.3 Selecting the Traffic Modules for the Tellabs 6325 Node - WDM
Stand-alone Configurations 29
1.5.4 WDM Link Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
1.6 Selecting the Transceivers for the Traffic Modules and Dedicated Units .
40
1.6.1 Selecting the Transceivers for the SDH Interfaces . . . . . . . . . 40
1.6.2 Selecting the Transceivers for the Ethernet Interfaces . . . . . . 44
1.6.3 Selecting the Transceivers for Bi-directional SDH/Ethernet Inter-
faces 47
1.6.4 Selecting the Transceivers for the Fibre Channel Interfaces . 48
1.7 Using Optical Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
1.8 Selecting the Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
1.8.1 Selecting the Traffic Interface Cables . . . . . . . . . . . . . . . . . . . 50
1.8.2 Selecting the Synchronization and Alarm Cables . . . . . . . . . . 52
1.8.3 Selecting the Management Cables . . . . . . . . . . . . . . . . . . . . . 52
1.8.4 Selecting the Power Cables . . . . . . . . . . . . . . . . . . . . . . . . . . 53
1.8.5 Selecting the EOW Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
1.9 Selecting the Embedded Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
2 Ordering Information for Tellabs 6325 Node . . . . . . . . . . . . . . . . . 55
2.1 Dedicated Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
2.2 Basic Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
2.3 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
2.4 Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2.5 Subrack Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
2.6 Balun Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
2.7 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
2.8 Embedded Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Tellabs

6325 Edge Node Contents


8 MA364 Rev. D2
MA364 Rev. D2 9
Tellabs

6325 Edge Node Preface


Preface
Purpose The purpose of this guide is to:
Describe how to configure the Tellabs 6325 node.
Provide a list of ordering numbers for the Tellabs 6325 node.
Prerequisite for using
this guide
This guide assumes that information from the network planning process is
available.
Product version This guide describes Tellabs 6325 node, feature pack 1.3.
Structure of the
configuration and
ordering guide
The guide is structured as follows:
1 Configuration Guide for Tellabs 6325 Node on page 11 describes pro-
cedures to configure Tellabs 6325 node.
2 Ordering Information for Tellabs 6325 Node on page 55 provides a list
of ordering numbers for Tellabs 6325 node.
Tellabs 6325 node
configurator tool
This guide is meant as a supplement to the Tellabs 6325 node configurator tool
and vice versa.
Abbreviations used in
this guide
3R Transponder performing Re-amplification, Re-shaping and
Re-timing of the incoming signal
ADM Add/Drop Multiplexer
CMCC Central Management and Communications Controller
CT Craft Terminal
CTE Channel Terminating Equipment
CWDM Coarse Wavelength Division Multiplexing
DC/DC DC/DC converter
DWDM Dense Wavelength Division Multiplexing
E1 Electrical interface at 2 Mbit/s
EMAP Ethernet MAPper
EOW Engineering Order Wire
ETEX Ethernet Tributary EXtension
FE Fast Ethernet
FP Feature Pack
GbE Gigabit Ethernet
Km Kilometer
Mbit/s Megabit per second
MP Muxponder module
MS-SPRing Multiplex Section Shared Protection Ring
NE Network Element
nm nanometer, (1*E-9 meter)
NM Network Management
OAD Optical Add/Drop module
OM Optical Multiplexer/Demultiplexer module
PDH Plesiochronous Digital Hierarchy
PIM PDH Interface Module
ps picoseconds
PS-DC Power Supply - DC (DC/DC converter)
SDXC Synchronous Digital Cross-Connect
SETS Synchronous Equipment Timing Source
SFP Small Formfactor Pluggable (Transceiver)
10 MA364 Rev. D2
Tellabs

6325 Edge Node Preface


SIMXm SDH Interfaces, Cross-connection and SETS Module with
non-intrusive PDH monitoring
SNC/I Inherently monitored Sub-Network Connection protection
SNC/N Non-intrusively monitored Sub-Network Connection pro-
tection
SPIMX SDH and PDH Interfaces and Cross-connection Module
SPIMXm SDH and PDH Interfaces, Cross-connection and SETS Mod-
ule with non-intrusive PDH monitoring
STM Synchronous Transport Module
STP Shielded twisted pair
SW Software
TR Transponder module
TRIB Tributary
VC-4 Virtual Container of 4'th order
VC-12 Virtual Container of 1st order
WDM Wavelength Division Multiplexing
XC Cross-connect (function)
References to Tellabs
documents
[1] 63xx_an010-1, Tellabs

63xx Nodes, Using external Optical Amplifier at


STM-16, Application Note.
MA364 Rev. D2 11
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1 Configuration Guide for Tellabs 6325 Node
Overview This describes how you configure a Tellabs 6325 node.
1.1 Tellabs 6325 Node Items on page 11
1.2 Configuring a Tellabs 6325 Node on page 13
1.3 Configuring a Tellabs 6325 Node by Selecting a Dedicated Unit on
page 14
1.4 Configuring a Tellabs 6325 Node by Selecting a Basic Unit on page 15
1.5 Configuring a Tellabs 6325 Node by Selecting Subrack and Modules
on page 17
1.6 Selecting the Transceivers for the Traffic Modules and Dedicated
Units on page 40
1.7 Using Optical Amplifiers on page 49
1.8 Selecting the Cables on page 49
1.9 Selecting the Embedded Software on page 53
1.1 Tellabs 6325 Node Items
Available items These items are available for the Tellabs 6325 node.
Item Description
Dedicated Units Three non-modular variants that are complete nodes
for which only transceivers have to be added. The
three variants have the following interfaces:
Variant 1: 4 x STM-1/STM-4 (with SFP) and 63 x
2 Mbit/s 120 ohm
Variant 2: 4 x STM-1/STM-4 (with SFP) and 21 x
2 Mbit/s 120 ohm
Variant 3: 4 x STM-1/STM-4 (with SFP), 21 x
2 Mbit/s 120 ohm, 2 x FE (RJ-45) and 2 x FE (RJ-45
or with SFP)
Basic Unit Pre-configured Tellabs 6325 node comprising a sub-
rack and a number of modules.
SC2 One rack unit (1RU) high subrack for the Tellabs
6325 node. Four slots for traffic modules. Various
modules can be installed in the subrack creating var-
ious configurations.
CMCC Central management and communications controller
module
PS-DC DC Power supply module (DC/DC converter)
AC/DC External AC/DC adapter
12 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


FAN Cooling module with the following interfaces:
synchronization input and output
alarm
SIMX4m SDH interface module, cross-connect and NE syn-
chronization (SETS) functions, non-intrusive PDH
monitoring, with the following transport interfaces:
4 x STM-1/STM-4 (with SFP)
SIMX16m SDH interface module, cross-connect and NE syn-
chronization (SETS) functions, non-intrusive PDH
monitoring, with the following transport interfaces:
1 x STM-16 (with SFP)
4 x STM-1/STM-4 (with SFP)
SPIMX SDH and PDH interface module, cross-connect and
NE synchronization (SETS) functions, with the fol-
lowing transport interfaces:
2 x STM-1/STM-4 (with SFP)
4 x 2 Mbit/s 120 ohm
SPIMXm SDH and PDH interface module, cross-connect and
NE synchronization (SETS) functions, non-intrusive
PDH monitoring, with the following transport inter-
faces:
2 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm
SPIMX16m SDH and PDH interface module, cross-connect and
NE synchronization (SETS) functions, non-intrusive
PDH monitoring, with the following transport inter-
faces:
1 x STM-1/STM-4/STM-16 (with SFP)
1 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm
PIM1 PDH interface module with the following transport
interfaces:
21 x 2 Mbit/s 120 ohm
PIM3P PDH interface module with the following transport
interfaces:
6 x 34/45 Mbit/s 75 ohm
Item Description
MA364 Rev. D2 13
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.2 Configuring a Tellabs 6325 Node
To configure the Tellabs
6325 node
There are three ways to configure the Tellabs 6325 node. They are as follows:
ETEX10S Ethernet switching and mapping module with
5 Gbit/s Ethernet switch. The module provides the
following transport interfaces:
4 x GbE (with SFP)
2 x FE (with SFP)
4 x FE (RJ-45)
EMAP Ethernet mapping module with the following trans-
port interfaces:
2 x FE (RJ-45)
2 x FE (RJ-45 or with SFP)
OM-C 8 channel CWDM multiplexer and demultiplexer
module.
OM-D 8 channel DWDM multiplexer and demultiplexer
module.
OAD1-C 1 channel CWDM optical add/drop multiplexer
module.
OAD1-D 1 channel DWDM optical add/drop multiplexer
module.
TR4 4 channel WDM transponder/repeater module.
MP4 4 channel WDM muxponder/transponder/repeater
module with NE synchronization (SETS) function.
Transceivers Pluggable transceivers (SFP) are used to provide the
desired optical or electrical interfaces.
Baluns 120/75 ohm baluns provide 2 Mbit/s 75 ohm inter-
faces.
Item Description
If then
you require a fixed configuration
covered by one of the three dedicat-
ed units and do not need the possi-
bility to expand or change your Tel-
labs 6325 node
Go to 1.3 Configuring a Tellabs 6325
Node by Selecting a Dedicated Unit
on page 14.
you require a configuration covered
by one of the pre-configured basic
units and the possibility to expand
or change your Tellabs 6325 node
Go to 1.4 Configuring a Tellabs 6325
Node by Selecting a Basic Unit on
page 15.
14 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.3 Configuring a Tellabs 6325 Node by Selecting a Dedicated Unit
To configure a Tellabs
6325 node with a
dedicated unit
This procedure describes how to configure a Tellabs 6325 node with one of the
dedicated units of the Tellabs 6325 node.
Item numbers of the
dedicated units
Select from the following units.
you want to configure the Tellabs
6325 node by selecting available sub-
rack and modules
Go to 1.5 Configuring a Tellabs 6325
Node by Selecting Subrack and
Modules on page 17.
If then
Step Action
1 Select the dedicated unit that fits your required application. The
units are listed in Item numbers of the dedicated units on page 14.
2 Select transceivers as described in 1.6 Selecting the Transceivers for
the Traffic Modules and Dedicated Units on page 40.
3 If required, select optical amplifier as described in 1.7 Using Optical
Amplifiers on page 49.
4 Select the cables as described in 1.8 Selecting the Cables on page 49.
Note: Two DC power cables are included when you order the dedi-
cated unit (CU...).
5 Select the embedded software as described in 1.9 Selecting the Em-
bedded Software on page 53.
Description Item number
Tellabs 6325 node - Dedicated Unit, two DC pow-
er cables included. The unit provides the follow-
ing interfaces:
4 x STM-1/STM-4 (with SFP)
63 x 2 Mbit/s 120 ohm
CU3561-001
Tellabs 6325 node - Dedicated Unit, two DC pow-
er cables included. The unit provides the follow-
ing interfaces:
4 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm
CU3561-002
MA364 Rev. D2 15
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.4 Configuring a Tellabs 6325 Node by Selecting a Basic Unit
To configure a Tellabs
6325 node with a basic
unit
This procedure describes how to configure a Tellabs 6325 node by selecting
one of the pre-configured basic units.
Tellabs 6325 node - Dedicated Unit, two DC pow-
er cables included. The unit provides the follow-
ing interfaces:
4 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm
2 x FE (RJ-45)
2 x FE (RJ-45 or with SFP)
CU3561-003
Description Item number
Step Action
1 Select the basic unit that fits your required application. The units are
listed in Item numbers of the basic units on page 16.
2 If you want to add traffic modules to the basic unit then go to Select-
ing additional modules on page 22.
3 Select transceivers as described in 1.6 Selecting the Transceivers for
the Traffic Modules and Dedicated Units on page 40.
4 If required, select optical amplifier as described in 1.7 Using Optical
Amplifiers on page 49.
5 Select the cables as described in 1.8 Selecting the Cables on page 49.
Note: Two DC power cables are included when you order the basic
unit (CU...).
6 Select the embedded software as described in 1.9 Selecting the Em-
bedded Software on page 53.
16 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Item numbers of the
basic units
Select from the following units.
Description Item number
SDXC, pre-configured Tellabs 6325 node, basic
unit comprising the following items:
1x SC2 subrack
1x SIMX4m module providing 4 x STM-
1/STM-4 (with SFP), slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
CU3560-001-A
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:
1x SC2 subrack
1x SPIMX module providing 4 x STM-1/STM-
4 (with SFP) and 4 x 2 Mbit/s 120 Ohm, slot 3
in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
CU3560-003
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:
1x SC2 subrack
1x SPIMXm module providing 4 x STM-
1/STM-4 (with SFP) and 21 x 2 Mbit/s
120 Ohm, slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
CU3560-005-B
MA364 Rev. D2 17
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.5 Configuring a Tellabs 6325 Node by Selecting Subrack and
Modules
To configure a Tellabs
6325 node
This procedure describes how to configure a Tellabs 6325 node.
ADM16, pre-configured Tellabs 6325 node, basic
unit comprising the following items:
1x SC2 subrack
2x SIMX16m module each providing 1 x STM-
16 and 4 x STM-1/STM-4 (all with SFP), slot 2
and 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
2x Cover plate for traffic module slot
2x DC Power Cable
CU3560-006-A
Pre-configured Tellabs 6325 node, without traffic
modules, basic unit comprising the following
items:
1x SC2 subrack
2x PS-DC module
1x CMCC module
1x Fan module
4x Cover plate for traffic module slot
2x DC Power Cable
CU3560-007
Description Item number
Step Action
1 Select the common items as described in 1.5.1 Selecting the Subrack
and Support Modules for the Tellabs 6325 Node on page 18. These
items are required in any configuration.
2 If you require an SDH configuration then select the traffic modules
as described in 1.5.2 Selecting the Traffic Modules for the Tellabs
6325 Node - SDH Configurations on page 20.
SDH configurations are Tellabs 6325 nodes with cross-connect func-
tions, SDH/PDH/Ethernet interfaces etc.
3 If you require a WDM stand-alone configuration then select the traf-
fic modules as described in 1.5.3 Selecting the Traffic Modules for
the Tellabs 6325 Node - WDM Stand-alone Configurations on page
29.
WDM stand-alone configurations are Tellabs 6325 nodes with only
WDM modules installed. These configurations are also referred to as
Tellabs 6325 Wavelength Division Multiplexing nodes.
18 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.5.1 Selecting the Subrack and Support Modules for the Tellabs 6325 Node
Slots in the SC2 subrack The SC2 subrack is a front access subrack comprising 9 slots for modules.
Selecting common items In any configuration you need a subrack and support modules. Select the fol-
lowing items.
4 Select transceivers as described in 1.6 Selecting the Transceivers for
the Traffic Modules and Dedicated Units on page 40.
5 If required, select optical amplifier as described in 1.7 Using Optical
Amplifiers on page 49.
6 Select the cables as described in 1.8 Selecting the Cables on page 49.
7 Select the embedded software as described in 1.9 Selecting the Em-
bedded Software on page 53.
Step Action
Description Item number
SC2 subrack, one rack unit (1RU) high, four slots
for traffic modules. The following items are deliv-
ered with the subrack:
Adaptation brackets for 19 inch rack
Adaptation brackets for ETSI rack
Cover plate for slot 6
Extraction tool kit (includes module reset tool)
M4 x 8 screw and washer to attach ground
wire
UC3560
FAN module CM3565
CMCC, Central management and communica-
tions control module
CM3564
Power module(s) See Selecting power
modules on page 19
MA364 Rev. D2 19
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Selecting power modules Select the following power modules according to your requirement.
Common items The figure shows the common items required in any configuration.
If then
you want single DC supply select the following items:
CM3561-A (PS-DC)
NS-0295 (Cover plate for slot 8)
you want redundant DC supply select the following items:
2 x CM3561-A (PS-DC).
you want single AC supply select the following items:
CM3561-A (PS-DC)
CM3569 (AC/DC adapter)
NS-0295 (Cover plate for slot 8)
you want redundant AC supply select the following items:
2 x CM3561-A (PS-DC)
2 x CM3569 (AC/DC adapter)
you want one DC supply and one
AC supply
select the following items:
2 x CM3561-A (PS-DC)
1 x CM3569 (AC/DC adapter)
20 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.5.2 Selecting the Traffic Modules for the Tellabs 6325 Node - SDH
Configurations
To select the traffic
modules
Follow this procedure to select the traffic modules for SDH configurations.
The slots in the subrack are shown in Slots in the SC2 subrack on page 18.
Selecting the module to
perform the cross-
connect and NE
synchronization (SETS)
functions
The module that performs the cross-connect and NE synchronization (SETS)
functions is located in slot 3. Depending on which type of aggregate and trib-
utary signals required in the network element different modules can be select-
ed. Follow this procedure to select the module.
Note: The module in slot 3 (and 2) performs the non-intrusive monitoring
function of all E1/P12s in the network element. If you require the non-
intrusive monitoring function, then you must select a SIMX4m,
SIMX16m, SPIMXm or SPIMX16m module for slot 3 (and 2). The mon-
itoring function is not supported in the SPIMX module with four
2 Mbit/s (CM3563).
Step Action
1 Select the module to perform the cross-connect and NE synchroniza-
tion (SETS) functions. The module is located in slot 3 of the subrack.
Described in Selecting the module to perform the cross-connect and
NE synchronization (SETS) functions on page 20.
2 If your configuration requires protection of the cross-connect and NE
synchronization (SETS) functions then select the module to perform
the protection of the cross-connect and NE synchronization (SETS)
functions. The module is located in slot 2 of the subrack. Described in
Selecting the module to perform the protection of the cross-connect
and NE synchronization (SETS) functions on page 21.
3 Select additional traffic modules as described in Selecting additional
modules on page 22.
4 Find the item numbers of the traffic modules in Item numbers of
traffic modules on page 25.
5 Select the transceivers for the traffic modules as described in
1.6 Selecting the Transceivers for the Traffic Modules and Dedicated
Units on page 40.
If and then
your configuration re-
quires the possibility
for MS-SPRing protec-
tion at STM-16 level
- select the SIMX16m
module and add SFP
transceivers
MA364 Rev. D2 21
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Selecting the module to
perform the protection of
the cross-connect and
NE synchronization
(SETS) functions
The module that performs the protection of the cross-connect and NE syn-
chronization (SETS) functions is located in slot 2. Depending on which type of
aggregate and tributary signals required in the network element different
modules can be selected. Follow this procedure to select the module.
Note: The module types in slot 2 and 3 do not necessarily have to be the same
as long as they both have the cross-connect and NE synchronization
(SETS) functions. You may, for instance, have a SPIMX16m in slot 3 and
a SIMX4m in slot 2.
Note: The module in slot 3 (and 2) performs the non-intrusive monitoring
function on all E1/P12s in the network element. If you require the non-
intrusive monitoring function, then you must select a SIMX4m,
SIMX16m, SPIMXm or SPIMX16m module for slot 3 (and 2). The mon-
itoring function is not supported in the SPIMX module with four
2 Mbit/s (CM3563).
you want an STM-16
interface
up to four STM-1/
STM-4 interfaces
select the SIMX16m
module and add SFP
transceivers
one STM-1/STM-4
interface
up to 21 x 2 Mbit/s
interfaces
select the SPIMX16m
module and add SFP
transceivers. See also
Selecting external bal-
un to provide 2 Mbit/s
75 ohm interface on
page 24.
you want up to four
STM-1/STM-4 interfac-
es
- select the SIMX4m-
module and add SFP
transceivers
you want one or two
STM-1/STM-4 interfac-
es
up to four 2 Mbit/s in-
terfaces
select the SPIMX mod-
ule and add SFP trans-
ceivers. See also Select-
ing external balun to
provide 2 Mbit/s
75 ohm interface on
page 24.
up to 21 x 2 Mbit/s in-
terfaces
select the SPIMXm
module and add SFP
transceivers. See also
Selecting external bal-
un to provide 2 Mbit/s
75 ohm interface on
page 24.
If and then
If and then
your configuration re-
quires the possibility
for MS-SPRing protec-
tion at STM-16 level
- select the SIMX16m
module and add SFP
transceivers
22 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Selecting additional
modules
In addition to the interfaces present on the module you have selected perform-
ing the cross-connect and NE synchronization (SETS) functions (slot 3) and, if
required, protection of the cross-connect and NE synchronization (SETS)
functions (slot 2), modules can be installed in slot (2), 4 and 5 to extend the
number of interfaces. When the module for slot 3 (and 2) has been selected,
then calculate the number of additional interfaces your configuration re-
quires. Then select the type and number of modules that fits your configura-
tion. The type of modules to provide additional interfaces are as follows:
Note: The cross-connect function in slot 3 (and 2) supports the STM-1/4 inter-
faces in slot 4 and 5 with a total capacity corresponding to 8 VC-4s (each
slot). Using the SIMX4m module in slot 4 or 5 limits the total capacity
of the four STM-1/4 interfaces to 8 VC-4s.
you want an STM-16
interface
up to four STM-1/
STM-4 interfaces
select the SIMX16m
module and add SFP
transceivers
one STM-1/STM-4
interface
up to 21 x 2 Mbit/s
interfaces
select the SPIMX16m
module and add SFP
transceivers. See also
Selecting external bal-
un to provide 2 Mbit/s
75 ohm interface on
page 24.
you want up to four
STM-1/STM-4 interfac-
es
- select the SIMX4m
module and add SFP
transceivers
you want one or two
STM-1/STM-4 interfac-
es
up to four 2 Mbit/s in-
terfaces
select the SPIMX mod-
ule and add SFP trans-
ceivers. See also Select-
ing external balun to
provide 2 Mbit/s
75 ohm interface on
page 24.
up to 21 x 2 Mbit/s in-
terfaces
select the SPIMXm
module and add SFP
transceivers. See also
Selecting external bal-
un to provide 2 Mbit/s
75 ohm interface on
page 24.
If and then
Module Interfaces Slot
SIMX16m 1 x STM-16 (with SFP)
4 x STM-1/STM-4 (with SFP)
2
SIMX4m 4 x STM-1/STM-4 (with SFP) 2, 4, 5
MA364 Rev. D2 23
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


SPIMX16m 1 x STM-1/STM-4/STM-16 (with
SFP)
1 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm
2
SPIMXm 2 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm
2, 4, 5
SPIMX 2 x STM-1/STM-4 (with SFP)
4 x 2 Mbit/s 120 ohm
2, 4, 5
PIM1 21 x 2 Mbit/s 120 ohm 2, 4, 5
PIM3P 6 x 34/45 Mbit/s 75 ohm
To enable equipment protection of the
mapping function the two PIM3P mod-
ules have to be installed in slot 4 and 5.
2, 4, 5
ETEX10S 4 x GbE (with SFP)
2 x FE (with SFP)
4 x FE (RJ-45)
4 + 5
EMAP 2 x FE (RJ-45)
2 x FE (RJ-45 or with SFP)
2, 4, 5
OM-C 8 channel CWDM multiplexer and de-
multiplexer module. The channel wave-
lengths are 1471, 1491, 1511, 1531, 1551,
1571, 1591 and 1611 nm
2, 4, 5
OM-D 8 channel DWDM multiplexer and de-
multiplexer module. The channel fre-
quencies are 192.9, 193.0, 193.1, 193.2,
193.3, 193.4, 193.5 and 193.6 THz
2, 4, 5
OAD1-C 1 channel CWDM optical add/drop
multiplexer module. Select between the
following add/drop channel wave-
lengths: 1471, 1491, 1511, 1531, 1551,
1571, 1591 and 1611 nm
2, 4, 5
OAD1-D 1 channel DWDM optical add/drop
multiplexer module. Select between the
following add/drop channel frequen-
cies: 192.9, 193.0, 193.1, 193.2, 193.3,
193.4, 193.5 and 193.6 THz
2, 4, 5
Module Interfaces Slot
24 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


For systems with WDM modules see also WDM configurations on page 29.
For 2 Mbit/s 75 ohm interfaces see Selecting external balun to provide 2
Mbit/s 75 ohm interface on page 24.
For equipment protection reasons you may consider the possibility to split the
SDH interfaces on separate modules.
Note: Remember to order cover plates (item number NS-0292) for slots not
used by modules.
Note: When you install SIMX and SPIMX modules it is recommended to start
with slot 2, then slot 4 and then slot 5. When you install PIM1 modules
it is recommended to start with slot 5, then slot 4 and then slot 2. How-
ever if your configuration requires an ETEX10S module the PIM1 mod-
ule can only be placed in slot 2.
Selecting external balun
to provide 2 Mbit/s
75 ohm interface
The 2 Mbit/s interfaces on the SPIMX and PIM1 modules are 120 ohm inter-
faces. If your configuration requires 75 ohm interfaces you must add the fol-
lowing items:
two external 120/75 ohm baluns per 2 Mbit/s interface. The balun has a
BNC connector and has to be installed in a balun panel. The balun item
number is WK-511B-KIT.
a balun panel kit BNC (item number NS-0299). Up to 42 baluns can be in-
stalled in the balun panel.
an open ended cable as used for the 120 ohm interface. See Electrical ca-
bles - 120 ohm on page 51.
The balun WK-511B-KIT provides only one connection. So you need two WK-
511B-KIT for a 2 Mbit/s interface, one for input and one for output connec-
tions.
TR4 4 channel WDM transponder/repeater
module. A maximum of two TR4/MP4
modules can be installed in a subrack. If
the configuration requires two modules
then use one of the following slot com-
binations:
2 and 5
4 and 5
2, 4, 5
MP4 4 channel WDM muxponder/transpon-
der/repeater module. A maximum of
two TR4/MP4 modules can be installed
in a subrack. If the configuration re-
quires two modules then use one of the
following slot combinations:
2 and 5
4 and 5
2, 4, 5
Module Interfaces Slot
MA364 Rev. D2 25
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Item numbers of traffic
modules
Select from the following traffic modules.
Description Item number
SDH / PDH
SIMX16m, SDH interface module, cross-connect
and NE synchronization (SETS) functions, non-
intrusive PDH monitoring, with the interfaces:
1 x STM-16 (with SFP)
4 x STM-1/STM-4 (with SFP)
CM3568-A
SIMX4m, SDH interface module, cross-connect
and NE synchronization (SETS) functions, non-
intrusive PDH monitoring, with the interfaces:
4 x STM-1/STM-4 (with SFP)
CM3567-A
SPIMX16m, SDH and PDH interface module,
cross-connect and NE synchronization (SETS)
functions, non-intrusive PDH monitoring, with
the interfaces:
1 x STM-1/STM-4/STM-16 (with SFP)
1 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-
ing external baluns.
CM3575
SPIMXm, SDH and PDH interface module, cross-
connect and NE synchronization (SETS) func-
tions, non-intrusive PDH monitoring, with the in-
terfaces:
2 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-
ing external baluns.
CM3574-A
SPIMX, SDH and PDH interface module, cross-
connect and NE synchronization (SETS) func-
tions, with the interfaces:
2 x STM-1/STM-4 (with SFP)
4 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-
ing external baluns.
CM3563
PIM3P, PDH interface module, with the interfac-
es:
6 x 34/45 Mbit/s (E3/DS3) 75 Ohm
CM3579
26 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


PIM1, PDH interface module, with the interfaces:
21 x 2 Mbit/s (E1) 120 Ohm
Note: 75 ohm interfaces are available using an ex-
ternal balun.
CM3566
Ethernet
ETEX10S, Ethernet switching and mapping mod-
ule, with the interfaces:
4 x GbE (with SFP)
2 x FE (with SFP)
4 x FE (RJ-45)
CM3572
EMAP, Ethernet mapping module, with the inter-
faces:
2 x FE (RJ-45)
2 x FE (RJ-45 or with SFP)
CM3571
Optical multiplexer/demultiplexer
OM-C, 8 channel CWDM multiplexer and demul-
tiplexer module
CM3580C
OM-D, 8 channel DWDM multiplexer and de-
multiplexer module
CM3580D
Optical add/drop multiplexer
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1471 nm
CM3581C-471
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1491 nm
CM3581C-491
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1511 nm
CM3581C-511
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1531 nm
CM3581C-531
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1551 nm
CM3581C-551
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1571 nm
CM3581C-571
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1591 nm
CM3581C-591
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1611 nm
CM3581C-611
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 192.90 THz
CM3581D-290
Description Item number
MA364 Rev. D2 27
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.00 THz
CM3581D-300
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.10 THz
CM3581D-310
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.20 THz
CM3581D-320
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.30 THz
CM3581D-330
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.40 THz
CM3581D-340
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.50 THz
CM3581D-350
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.60 THz
CM3581D-360
Transponder/repeater/muxponder
TR4, 4 channel WDM transponder/repeater
module
Note: When using the TR4 or MP4 modules a
high frequency ferrite filter clamp on the power
supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission re-
quirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
CM3582
MP4, 4 channel WDM muxponder/transpon-
der/repeater module
Note: When using the TR4 or MP4 modules a
high frequency ferrite filter clamp on the power
supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission re-
quirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
CM3585
Cover plate
Cover plate for traffic module position NS-0292
Description Item number
28 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Example - ADM16 with 8
STM-1/STM-4 interfaces
and ETEX
The following example shows an ADM16 with 8 STM-1/STM-4 interfaces and
with an Ethernet switching and mapping module.
Items included in the example are:
Interconnecting Tellabs
6325 nodes to extend
number of interfaces
It is possible to extend the configuration with another subrack if the number
of required interfaces exceed the capacity in one subrack. By interconnecting
two Tellabs 6325 nodes, through the cross-connect modules in slot 3, you dou-
ble the number of available slots for traffic modules. In the management sys-
tem the two nodes will be seen as two separate network elements.
Example - ADM4 with
126 x 2 Mbit/s interfaces
The following example shows an ADM4 with 126 x 2 Mbit/s interfaces. It is
realized by interconnecting two Tellabs 6325 nodes through STM-1 connec-
tions. This example shows two SIMX4m modules interconnected. This makes
it possible to have six PIM1 modules with a total of 126 x 2 Mbit/s interfaces.
Description Item number
SC2 subrack UC3560
FAN CM3565
CMCC CM3564
2 x PS-DC CM3561-A
2 x SIMX16m CM3568-A
ETEX10S CM3572
MA364 Rev. D2 29
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.5.3 Selecting the Traffic Modules for the Tellabs 6325 Node - WDM Stand-
alone Configurations
To select the traffic
modules
Follow this procedure to select the traffic modules for WDM stand-alone con-
figurations. These configurations are also referred to as Tellabs 6325 Wave-
length Division Multiplexing nodes.
The slots in the subrack are shown in Slots in the SC2 subrack on page 18.
WDM configurations The following WDM configurations are possible with the Tellabs 6325 node.
Step Action
1 Select the required WDM configuration as described in WDM con-
figurations on page 29.
See also 1.5.4 WDM Link Design on page 37.
2 Select the traffic modules as described in Selecting the WDM mod-
ules on page 34.
3 Find the item numbers of the traffic modules in Item numbers of
traffic modules on page 35.
4 Select the transceivers for the traffic modules as described in
1.6 Selecting the Transceivers for the Traffic Modules and Dedicated
Units on page 40.
If then
you require
an 8-channel
CWDM mul-
tiplexer and
demultiplexer
select the OM-C module.
30 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


you require
an 8-channel
DWDM mul-
tiplexer and
demultiplexer
select the OM-D module.
you require a
15-channel
combined
CWDM and
DWDM mul-
tiplexer and
demultiplexer
select the OM-C and OM-D modules.
If then
MA364 Rev. D2 31
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


you require a
1-channel
CWDM
add/drop
multiplexer
select the OAD1-C module.
you require a
1-channel
DWDM
add/drop
multiplexer
select the OAD1-D module.
you require a
4-channel
transponder/
repeater
select the TR4 module and add SFP transceivers. See also
Using the MP4/TR4 module on page 33.
If then
32 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


you require a
4-channel
muxponder/
transponder/
repeater
select the MP4 module and add SFP transceivers. The MP4
module can operate in the following three configurations
controlled by the management software. See also Using
the MP4/TR4 module on page 33.
If then
MA364 Rev. D2 33
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Using the MP4/TR4
module
The MP4 module can be used either as a Transponder/Repeater, similar to a
TR4 module, or as a Muxponder.
The Muxponder is able to multiplex/demultiplex signals on certain ports. A
description of the signals and ports is shown in the table below. The module
is capable of dual multiplexing/demultiplexing (4 signals to 2 signals). The
functionality (TR/MUX-1/MUX-2) of the MP4 module is set using the ele-
ment manager software.
Possible signals Port connections
TRP/REP (MP4 and TR4 modules)
STM-4/OC-12, STM-16/OC-48,
1000BASE-X, FC-100, FC-200, FC-
400
1 2
3 4
5 6
7 8
MUX-1 (MP4 module)
Client: 1000BASE-X, FC-100
Line: 1 x STM-16
1 2, 3
5 6
7 8
MUX-2 (MP4 module)
Client: 1000BASE-X, FC-100
Line: 2 x STM-16
1 2, 3
5 4, 6
7 8
34 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Selecting the WDM
modules
Select the type and number of modules that fits your configuration. The type
of modules are as follows:
Note: If you require the NE synchronization (SETS) function in the subrack
then an MP4 module must be installed in slot 3.
Module Interfaces Slot
OM-C 8 channel CWDM multiplexer and demul-
tiplexer module. The channel wavelengths
are 1471, 1491, 1511, 1531, 1551, 1571, 1591
and 1611 nm
2, 3, 4, 5
OM-D 8 channel DWDM multiplexer and demul-
tiplexer module. The channel frequencies
are 192.9, 193.0, 193.1, 193.2, 193.3, 193.4,
193.5 and 193.6 THz
2, 3, 4, 5
OAD1-C 1 channel CWDM optical add/drop multi-
plexer module. Select between the follow-
ing add/drop channel wavelengths: 1471,
1491, 1511, 1531, 1551, 1571, 1591 and 1611
nm
2, 3, 4, 5
OAD1-D 1 channel DWDM optical add/drop multi-
plexer module. Select between the follow-
ing add/drop channel frequencies: 192.9,
193.0, 193.1, 193.2, 193.3, 193.4, 193.5 and
193.6 THz
2, 3, 4, 5
TR4 4 channel WDM transponder/repeater
module. A maximum of two TR4/MP4
modules can be installed in a subrack. If
the configuration requires two modules
then use one of the following slot combina-
tions:
2 and 3
2 and 5
3 and 4
4 and 5
2, 3, 4, 5
MP4 4 channel WDM muxponder/transpon-
der/repeater module with NE synchroni-
zation (SETS) function. A maximum of two
TR4/MP4 modules can be installed in a
subrack. If the configuration requires two
modules then use one of the following slot
combinations:
2 and 3
2 and 5
3 and 4
4 and 5
Note: The MP4 module must be installed in
slot 3 to support the NE synchronization
(SETS) function.
2, 3, 4, 5
MA364 Rev. D2 35
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Note: Remember to order cover plates (item number NS-0292) for slots not
used by modules.
Item numbers of traffic
modules
Select from the following traffic modules.
Description Item number
Optical multiplexer/demultiplexer
OM-C, 8 channel CWDM multiplexer and demul-
tiplexer module
CM3580C
OM-D, 8 channel DWDM multiplexer and de-
multiplexer module
CM3580D
Optical add/drop multiplexer
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1471 nm
CM3581C-471
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1491 nm
CM3581C-491
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1511 nm
CM3581C-511
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1531 nm
CM3581C-531
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1551 nm
CM3581C-551
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1571 nm
CM3581C-571
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1591 nm
CM3581C-591
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1611 nm
CM3581C-611
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 192.90 THz
CM3581D-290
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.00 THz
CM3581D-300
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.10 THz
CM3581D-310
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.20 THz
CM3581D-320
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.30 THz
CM3581D-330
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.40 THz
CM3581D-340
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.50 THz
CM3581D-350
36 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.60 THz
CM3581D-360
Transponder/repeater/muxponder
TR4, 4 channel WDM transponder/repeater
module
Note: When using the TR4 or MP4 modules a
high frequency ferrite filter clamp on the power
supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission re-
quirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
CM3582
MP4, 4 channel WDM muxponder/transpon-
der/repeater module, NE synchronization (SETS)
function.
Note: When using the TR4 or MP4 modules a
high frequency ferrite filter clamp on the power
supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission re-
quirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
CM3585
Cover plate
Cover plate for traffic module position NS-0292
Description Item number
MA364 Rev. D2 37
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.5.4 WDM Link Design
Introduction When selecting the equipment for a WDM system it is recommended also to
have a power budget for the link. The following shows power budgets for dif-
ferent configurations.
Point to Point configuration on page 37
Optical Add/Drop configuration with OAD module on page 38
Optical Add/Drop back-to-back configuration with OM modules on
page 39
Point to Point
configuration
Make a power budget for a point-to-point link with either STM-16 CWDM or
STM-16 DWDM as shown in the following tables.
Power budget for a point-to-point link with STM-16 CWDM.
Power budget for a point-to-point link with STM-16 DWDM
Parameter Value Unit
Tx launch power (Minimum) 0.0 dBm
Receive sensitivity -28.0 dBm
Insertion loss OM-C (Mux/Demux modules) 4.0 dB
Path penalty 2.0 dB
Span attenuation (connectors, ODF, splices
etc. and margin included)
22.0 dB
Parameter Value Unit
Tx launch power (Minimum) 0.0 dBm
Receive sensitivity -28.0 dBm
Paired insertion loss OM-D (Mux/Demux
modules) (Maximum)
6.0 dB
Path penalty 2.0 dB
Span attenuation (connectors, ODF, splices
etc. and margin included)
20.0 dB
38 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Optical Add/Drop
configuration with OAD
module
Make a power budget for an optical Add/Drop link (with OAD module) with
either STM-16 CWDM or STM-16 DWDM as shown in the following tables.
Power budget for an optical Add/Drop link (with OAD module) with STM-
16 CWDM.
Power budget for an optical Add/Drop link (with OAD module) with STM-
16 DWDM
Parameter Value Unit
Tx launch power (Minimum) 0.0 dBm
Receive sensitivity -28.0 dBm
Insertion loss OM-C (Mux/Demux modules) 4.0 dB
Insertion loss OAD1-C (Add/Drop module),
pass-through channels
2.0 dB
Path penalty 2.0 dB
Span attenuation (connectors, ODF, splices
etc. and margin included)
20.0 dB
Parameter Value Unit
Tx launch power (Minimum) 0.0 dBm
Receive sensitivity -28.0 dBm
Paired insertion loss OM-D (Mux/Demux
modules) (Maximum)
6.0 dB
Insertion loss OAD1-D (Add/Drop module),
pass-through channels
3.0 dB
Path penalty 2.0 dB
Span attenuation (connectors, ODF, splices
etc. and margin included)
17.0 dB
MA364 Rev. D2 39
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Optical Add/Drop back-
to-back configuration
with OM modules
Make a power budget for an optical Add/Drop back-to-back link with either
STM-16 CWDM or STM-16 DWDM as shown in the following tables.
Power budget for an optical Add/Drop back-to-back link with STM-16
CWDM.
Power budget for an optical Add/Drop back-to-back link with STM-16
DWDM
Parameter Value Unit
Tx launch power (Minimum) 0.0 dBm
Receive sensitivity -28.0 dBm
Insertion loss OM-C (Mux/Demux modules) 4.0 dB
Insertion loss OM-C (Mux/Demux modules),
pass-through channels
4.0 dB
Path penalty 2.0 dB
Span attenuation (connectors, ODF, splices
etc. and margin included)
18.0 dB
Parameter Value Unit
Tx launch power (Minimum) 0.0 dBm
Receive sensitivity -28.0 dBm
Paired insertion loss OM-D (Mux/Demux
modules) (Maximum)
6.0 dB
Paired insertion loss OM-D (Mux/Demux
modules), pass-through channels
6.0 dB
Path penalty 2.0 dB
Span attenuation (connectors, ODF, splices
etc. and margin included)
14.0 dB
40 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.6 Selecting the Transceivers for the Traffic Modules and
Dedicated Units
Overview Select the transceivers for the traffic modules and dedicated units as described
in:
1.6.1 Selecting the Transceivers for the SDH Interfaces on page 40
1.6.2 Selecting the Transceivers for the Ethernet Interfaces on page 44
1.6.3 Selecting the Transceivers for Bi-directional SDH/Ethernet Interfac-
es on page 47
1.6.4 Selecting the Transceivers for the Fibre Channel Interfaces on page
48
1.6.1 Selecting the Transceivers for the SDH Interfaces
Selecting transceivers
for the SIMX and SPIMX
modules and the
Dedicated Units
The dispersion characteristics and attenuation for each specific interface is de-
termined by an application code of the transceivers.
Note: If your configuration requires an optical amplifier, then go to 1.7 Using
Optical Amplifiers on page 49.
If the interface type is then
electrical STM-1 select the electrical STM-1 SFP with 1.0/2.3 coaxi-
al connectors.
Note: About size of electrical STM-1 SFPs: The
two connectors together, on the cables for the elec-
trical STM-1 interface, are a little wider than the
transceiver. Due to this it will not be possible to in-
stall two electrical STM-1 transceivers in the cages
next to one another on the Dedicated Units. It
might (depending on the connector type) also be
difficult to replace a transceiver in neighbor posi-
tion to an electrical STM-1 transceiver, without
disconnecting the electrical cables on the neighbor
position. This is the case only with the Dedicated
Units. On the SIMX4m, SIMX16m and SPIMX
modules the space between the cages makes it
possible to install electrical STM-1 transceivers in
all STM-1/4 cages.
optical STM-1 go to Selecting transceivers for optical STM-1 in-
terface on page 41
STM-4 go to Selecting transceivers for STM-4 interface
on page 41
STM-16 go to Selecting transceivers for STM-16 interface
on page 41
MA364 Rev. D2 41
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Selecting transceivers
for optical STM-1
interface
The type of transceivers that you select for the optical STM-1 interface, is de-
termined by the transmission wavelength and the attenuation of the fibre con-
nection to the neighboring NE. The attenuation parameter is found by making
a power budget for the system.
Selecting transceivers
for STM-4 interface
The type of transceivers that you select for the STM-4 interface, is determined
by the transmission wavelength and the attenuation characteristics of the fibre
connection to the neighboring NE. The attenuation parameters is found by
making a power budget for the system.
Selecting transceivers
for STM-16 interface
The type of transceivers that you select for STM-16 interface, is determined by
the transmission wavelength, attenuation and the dispersion characteristics of
the fibre connection to the neighboring NE. The attenuation and dispersion
parameters are found by making a power budget for the system.
if transmission wave-
length is
and If point S-R specifi-
cation
then
1310 nm (short haul in-
terface)
attenuation is 0-12 dB select the application
code S-1.1
1310 nm (long haul in-
terface)
attenuation is 10-28 dB select the application
code L-1.1
1550 nm (long haul in-
terface)
attenuation is 10-28 dB select the application
code L-1.2
1550 nm (very long
haul interface)
attenuation is 15-33 dB select the application
code V-1.2
if transmission wave-
length is
and If point S-R specifi-
cation
then
1310 nm (short haul in-
terface)
attenuation is 0-12 dB select the application
code S-4.1
1310 nm (long haul in-
terface)
attenuation is 10-24 dB select the application
code L-4.1
1550 nm (long haul in-
terface)
attenuation is 10-24 dB select the application
code L-4.2
if transmission wave-
length is
and If point S-R specifi-
cation
then
1310 nm (short haul in-
terface)
attenuation is 0-12 dB select the application
code S-16.1
1310 nm (long haul in-
terface)
attenuation is 10-24 dB select the application
code L-16.1
1550 nm (long haul in-
terface)
attenuation is 10-24 dB
and dispersion is <1600
ps/nm
select the application
code L-16.2
wavelength specific
(CWDM)
attenuation is 12-24 dB
and dispersion is <1600
ps/nm
select STM-16 CWDM
42 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Item numbers of
transceivers
Select from the following transceivers.
wavelength specific
(DWDM)
attenuation is 10-26 dB
and dispersion is <2400
ps/nm
select STM-16 DWDM
if transmission wave-
length is
and If point S-R specifi-
cation
then
Description Item number
SDH
SDH transceiver, SFP, 1.0/2.3 coaxial connectors,
75 ohm. For the applications:
STM-1 electrical
TR-0021
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
S-1.1
FE
TR-0001
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
L-1.1
FE
TR-0002
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
L-1.2
FE
TR-0003
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
V-1.2
TR-0019-551
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
S-4.1
TR-0004
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
L-4.1
TR-0005
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
L-4.2
TR-0006
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
S-16.1
TR-0007
MA364 Rev. D2 43
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
L-16.1
TR-0008
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
L-16.2
TR-0009
Bi-directional SDH
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.2
100BASE-BX-D
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.1
100BASE-BX-U
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.2
1000BASE-BX-D
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.1
1000BASE-BX-U
TR-0026-U
SDH WDM
SDH/Ethernet CWDM transceivers, multirate,
available wavelengths are 1471 nm - 1611 nm
with 20 nm spacing, 1600 ps/nm, SFP, LC con-
nectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0020-xxx
Description Item number
44 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.6.2 Selecting the Transceivers for the Ethernet Interfaces
Transceivers for
Ethernet interfaces
Select from the following transceivers.
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC con-
nectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.
TR-0018-xxx
Description Item number
Description Item number
Fast Ethernet
Ethernet transceiver, SFP, RJ-45 connector,
shielded twisted pair. For the applications:
10/100BASE-T
TR-0027
Ethernet transceiver, SFP, LC connectors, multi
mode fiber. For the applications:
100BASE-FX
TR-0010
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:
100BASE-LX10
TR-0022
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
S-1.1
FE
TR-0001
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
L-1.1
FE
TR-0002
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
L-1.2
FE
TR-0003
MA364 Rev. D2 45
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Gigabit Ethernet
Ethernet transceiver, SFP, RJ-45 connector,
shielded twisted pair. For the applications:
1000BASE-T
TR-0013
Ethernet/Fibre Channel transceiver, SFP, LC con-
nectors, multi mode fiber. For the applications:
1000BASE-SX
FC-100/200
TR-0011
Ethernet/Fibre Channel transceiver, SFP, LC con-
nectors, multi/single mode fiber. For the applica-
tions:
1000BASE-LX10
FC-100
TR-0012
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:
1000BASE-ZX
TR-0023
Ethernet/Fibre Channel transceiver, multirate,
850 nm, SFP, LC connectors, multi mode fiber.
For the applications:
1000BASE-SX
FC-100/200/400
TR-0029
Bi-directional Ethernet
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.2
100BASE-BX-D
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.1
100BASE-BX-U
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.2
1000BASE-BX-D
TR-0026-D
Description Item number
46 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.1
1000BASE-BX-U
TR-0026-U
Ethernet WDM
SDH/Ethernet CWDM transceivers, multirate,
available wavelengths are 1471 nm - 1611 nm
with 20 nm spacing, 1600 ps/nm, SFP, LC con-
nectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0020-xxx
Ethernet/Fibre Channel CWDM transceivers,
multirate, available wavelengths are 1471 nm -
1611 nm with 20 nm spacing, SFP, LC connectors,
single mode fiber. For the applications:
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0031-xxx
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC con-
nectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.
TR-0018-xxx
Ethernet/Fibre Channel DWDM transceivers,
multirate, available frequencies are 192.90 THz -
193.60 THz with 100 GHz spacing, SFP, LC con-
nectors, single mode fiber. For the applications:
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific frequency e.g. 290 in
the frequency 192.90 THz.
TR-0032-xxx
Description Item number
MA364 Rev. D2 47
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.6.3 Selecting the Transceivers for Bi-directional SDH/Ethernet Interfaces
Selecting the bi-
directional transceivers
If you want to send traffic in both directions using only one fiber then select
the bi-directional transceivers. Select a set of transceivers (-D/-U). The D-
transceiver transmitting at 1550nm is used in one end of the fiber and the U-
transceiver transmitting at 1310nm is used at the other end of the fiber.
The attenuation range for the STM-1 transceivers is 0-13 dB and the attenua-
tion range for the STM-4 transceivers is 0-10 dB.
Transceivers for STM-1 /
100BASE-BX bi-
directional interfaces
Select the following transceivers.
Transceivers for STM-4 /
1000BASE-BX bi-
directional interfaces
Select the following transceivers.
Description Item number
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.2
100BASE-BX-D
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.1
100BASE-BX-U
TR-0025-U
Description Item number
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.2
1000BASE-BX-D
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.1
1000BASE-BX-U
TR-0026-U
48 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.6.4 Selecting the Transceivers for the Fibre Channel Interfaces
Transceivers for Fibre
Channel interfaces
Select from the following transceivers.
Description Item number
Fibre Channel
Ethernet/Fibre Channel transceiver, SFP, LC con-
nectors, multi mode fiber. For the applications:
1000BASE-SX
FC-100/200
TR-0011
Ethernet/Fibre Channel transceiver, SFP, LC con-
nectors, multi/single mode fiber. For the applica-
tions:
1000BASE-LX10
FC-100
TR-0012
Ethernet/Fibre Channel transceiver, multirate,
850 nm, SFP, LC connectors, multi mode fiber.
For the applications:
1000BASE-SX
FC-100/200/400
TR-0029
Fibre Channel transceiver, multirate, 1310 nm,
SFP, LC connectors, single mode fiber. For the ap-
plications:
FC-100/200/400
TR-0030
Fibre Channel WDM
Ethernet/Fibre Channel CWDM transceivers,
multirate, available wavelengths are 1471 nm -
1611 nm with 20 nm spacing, SFP, LC connectors,
single mode fiber. For the applications:
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0031-xxx
Ethernet/Fibre Channel DWDM transceivers,
multirate, available frequencies are 192.90 THz -
193.60 THz with 100 GHz spacing, SFP, LC con-
nectors, single mode fiber. For the applications:
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific frequency e.g. 290 in
the frequency 192.90 THz.
TR-0032-xxx
MA364 Rev. D2 49
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.7 Using Optical Amplifiers
Introduction For a standard G.957 L-16.2 interface the distance between two nodes are lim-
ited to 80 km over a standard G.652 fiber. To reach longer distances, it is nec-
essary to add a re-generator in the middle of the span, boost the output level
and/or improve the sensitivity of the receiver.
Using an external Optical Amplifier it is possible to increase the distance be-
tween two Tellabs 63xx nodes up to approx. 180 km depending on actual loss
and dispersion of the link.
Using optical amplifiers to increase the distance between Tellabs 63xx Nodes
is described in an application note [1].
1.8 Selecting the Cables
Type of cables available The following type of cables are used for a Tellabs 6325 node.
Cables Used for
Traffic interface cables Connection of traffic interfaces. See
1.8.1 Selecting the Traffic Interface Cables on
page 50.
Synchronization and
alarm cables
2 MHz input or output synchronization signals
and alarm signals. See 1.8.2 Selecting the Syn-
chronization and Alarm Cables on page 52.
Management cables Connection of network management, element
manager and craft terminal. See 1.8.3 Selecting
the Management Cables on page 52.
Power cables Power connection to the PS-DC module. See
1.8.4 Selecting the Power Cables on page 53.
EOW cables EOW connection to the EOW system. See
1.8.5 Selecting the EOW Cables on page 53.
50 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.8.1 Selecting the Traffic Interface Cables
Overview Select the cables to be used for the modules/units.
Optical cables For optical interfaces, select between the following cables.
Module/Unit Interface Cables
Dedicated Unit STM-4, optical STM-1
and optical Fast Ether-
net
See Optical cables on
page 50
electrical STM-1 See Electrical cables -
75 ohm on page 52
2 Mbit/s 120 ohm See Electrical cables -
120 ohm on page 51
electrical Fast Ethernet Use standard Ethernet
cables. See Ethernet in-
terface cables on page
52
SIMX STM-16, STM-4 and op-
tical STM-1
See Optical cables on
page 50
electrical STM-1 See Electrical cables -
75 ohm on page 52
SPIMX STM-16, STM-4 and op-
tical STM-1
See Optical cables on
page 50
electrical STM-1 See Electrical cables -
75 ohm on page 52
2 Mbit/s 120 ohm See Electrical cables -
120 ohm on page 51
PIM3P 34/45 Mbit/s See Electrical cables -
75 ohm on page 52
PIM1 2 Mbit/s 120 ohm See Electrical cables -
120 ohm on page 51
ETEX10S, EMAP optical See Optical cables on
page 50
electrical Use standard Ethernet
cables. See Ethernet in-
terface cables on page
52
OM-C, OM-D, OAD1-
C, OAD1-D, TR4, MP4
optical See Optical cables on
page 50
MA364 Rev. D2 51
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Note: Optical transceivers use an LC connector for the optical interface.
Electrical cables -
120 ohm
For SPIMX and PIM1 modules and Dedicated Units with 2 Mbit/s 120 ohm
interfaces, select between the following cables.
Description Item number
Optical single mode fiber cables, two fibers in one cable
2xLC to 2xLC single mode fiber cable, 0.3 m W-OF203/00.3
2xLC to 2xLC single mode fiber cable, 5 m W-OF203/05.0
2xLC to 2xLC single mode fiber cable, 10 m W-OF203/10.0
2xLC to 2xLC single mode fiber cable, 20 m W-OF203/20.0
2xLC to 2xFC/PC single mode fiber cable, 5 m W-OF204/05.0
2xLC to 2xFC/PC single mode fiber cable, 10 m W-OF204/10.0
2xLC to 2xFC/PC single mode fiber cable, 20 m W-OF204/20.0
2xLC to 2xSC single mode fiber cable, 5 m W-OF205/05.0
2xLC to 2xSC single mode fiber cable, 10 m W-OF205/10.0
2xLC to 2xSC single mode fiber cable, 20 m W-OF205/20.0
Optical multi mode fiber cables, two fibers in one cable
2xLC to 2xLC multi mode fiber cable, 5 m W-OF207/05.0
2xLC to 2xLC multi mode fiber cable, 10 m W-OF207/10.0
2xLC to 2xLC multi mode fiber cable, 20 m W-OF207/20.0
Description Item number
Cables for SPIMX module with 4 x 2 Mbit/s
RJ-45 to open ended cable, 120 ohm, 5 m WK-504Y-05.0-10
RJ-45 to open ended cable, 120 ohm, 10 m WK-504Y-10.0-10
RJ-45 to open ended cable, 120 ohm, 20 m WK-504Y-20.0-10
Cables for PIM1, SPIMX modules with 21 x 2 Mbit/s and Dedicated Units
MDR to open ended cable, 120 ohm, 5 m WK-503Y-05.0-12
MDR to open ended cable, 120 ohm, 10 m WK-503Y-10.0-12
MDR to open ended cable, 120 ohm, 20 m WK-503Y-20.0-12
52 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


Electrical cables -
75 ohm
For electrical STM-1 interfaces and 34/45 Mbit/s 75 ohm interfaces select be-
tween the following cables.
Note: For easier removal of the coaxial cables, an extraction tool (item number
TOOL-H030) can be used.
1.8.2 Selecting the Synchronization and Alarm Cables
Synchronization and
AUX alarm interface
cable
If you require a 2 MHz external synchronization input signal or synchroniza-
tion output signal, then select the following cable. This cable also connect to
four AUX alarms.
Note: The plug type on the module is 9 pol D-Sub.
1.8.3 Selecting the Management Cables
Ethernet interface cables Use standard STP Ethernet interface cables (RJ-45).
Craft terminal interface
cable
If your network element requires connection to a craft terminal, then select the
following cable. You require one cable per craft terminal.
Description Item number
1.0/2.3 to 1.0/2.3 coaxial cable, 5 m WK-482B-05.0-01
1.0/2.3 to 1.0/2.3 coaxial cable, 10 m WK-482B-10.0-01
1.0/2.3 to 1.0/2.3 coaxial cable, 20 m WK-482B-20.0-01
1.0/2.3 to BNC coaxial cable, 5 m WK-483B-05.0-01
1.0/2.3 to BNC coaxial cable, 10 m WK-483B-10.0-01
1.0/2.3 to BNC coaxial cable, 20 m WK-483B-20.0-01
1.0/2.3 to 1.6/5.6 coaxial cable, 5 m WK-484B-05.0-01
1.0/2.3 to 1.6/5.6 coaxial cable, 10 m WK-484B-10.0-01
1.0/2.3 to 1.6/5.6 coaxial cable, 20 m WK-484B-20.0-01
1.0/2.3 to open end coaxial cable, 20 m WK-497B-20.0-01
Description Item number
9 pole D-sub to open ended, 120 ohm, 3 m WK-502Y-03.0-01
Description Item number
Craft terminal interface cable, RJ-45 to 9 pole D-
sub, 3 m
WK-480X-03.0-01
MA364 Rev. D2 53
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


1.8.4 Selecting the Power Cables
Power cable Select the following power cable. You require one power cable per PS-DC
module. In case you want to use protected power you need two PS-DC mod-
ules and thereby also two power cables.
1.8.5 Selecting the EOW Cables
EOW cables If your system includes an EOW system, then select the following cable.
Note: On the SPIMX modules with 21 x 2 Mbit/s the EOW system is connect-
ed with the 2 Mbit/s interface cable (WK-503Y-zz.z-12 - ref. Electrical
cables - 120 ohm on page 51). The open ended cable holds both the con-
nections for the 2 Mbit/s interfaces and the EOW interface.
1.9 Selecting the Embedded Software
Embedded software You require an embedded software release which is delivered pre-installed on
the CMCC module. For the Tellabs 6325 node - Dedicated Unit the software
must be ordered separately. For upgrading of the embedded software in an
existing system the CD-ROM with the software can be ordered.
Description Item number
3 pole Molex mini-fit to open ended, 2.6 m
Note: When using the TR4 or MP4 modules a
high frequency ferrite filter clamp on the power
supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission re-
quirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
WK-500Z-02.6-01
Description Item number
RJ-45 to 15 pole D-sub, 3 m WK-501Y-03.0-01
Description Item number
6325 ESW, FP1.3, CD-ROM SW6325-0013M200
54 MA364 Rev. D2
Tellabs

6325 Edge Node 1 Configuration Guide for Tellabs 6325 Node


MA364 Rev. D2 55
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


2 Ordering Information for Tellabs 6325 Node
Overview This gives the item numbers available for Tellabs 6325 node.
2.1 Dedicated Units on page 55
2.2 Basic Units on page 56
2.3 Modules on page 57
2.4 Transceivers on page 61
2.5 Subrack Items on page 68
2.6 Balun Items on page 68
2.7 Cables on page 69
2.8 Embedded Software on page 71
2.1 Dedicated Units
Dedicated units The following Tellabs 6325 node - dedicated units are available.
Description Item number
Tellabs 6325 node - Dedicated Unit, two DC pow-
er cables included. The unit provides the follow-
ing interfaces:
4 x STM-1/STM-4 (with SFP)
63 x 2 Mbit/s 120 ohm
CU3561-001
Tellabs 6325 node - Dedicated Unit, two DC pow-
er cables included. The unit provides the follow-
ing interfaces:
4 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm
CU3561-002
Tellabs 6325 node - Dedicated Unit, two DC pow-
er cables included. The unit provides the follow-
ing interfaces:
4 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s 120 ohm
2 x FE (RJ-45)
2 x FE (RJ-45 or with SFP)
CU3561-003
56 MA364 Rev. D2
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


2.2 Basic Units
Basic units The following pre-configured Tellabs 6325 node basic units are available.
Description Item number
SDXC, pre-configured Tellabs 6325 node, basic
unit comprising the following items:
1x SC2 subrack
1x SIMX4m module providing 4 x STM-1/
STM-4 (with SFP), slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
CU3560-001-A
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:
1x SC2 subrack
1x SPIMX module providing 4 x STM-1/STM-
4 (with SFP) and 4 x 2 Mbit/s 120 Ohm, slot 3
in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
CU3560-003
ADM1/ADM4, pre-configured Tellabs 6325
node, basic unit comprising the following items:
1x SC2 subrack
1x SPIMXm module providing 4 x STM-1/
STM-4 (with SFP) and 21 x 2 Mbit/s 120 Ohm,
slot 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
3x Cover plate for traffic module slot
2x DC Power Cable
CU3560-005-B
MA364 Rev. D2 57
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


2.3 Modules
SDH and PDH modules The following SDH and PDH modules are available for the Tellabs 6325 node.
ADM16, pre-configured Tellabs 6325 node, basic
unit comprising the following items:
1x SC2 subrack
2x SIMX16m module each providing 1 x STM-
16 and 4 x STM-1/STM-4 (all with SFP), slot 2
and 3 in the subrack
2x PS-DC module
1x CMCC module
1x Fan module
2x Cover plate for traffic module slot
2x DC Power Cable
CU3560-006-A
Pre-configured Tellabs 6325 node, without traffic
modules, basic unit comprising the following
items:
1x SC2 subrack
2x PS-DC module
1x CMCC module
1x Fan module
4x Cover plate for traffic module slot
2x DC Power Cable
CU3560-007
Description Item number
Description Item number
SIMX16m, SDH interface module, cross-connect
and NE synchronization (SETS) functions, non-
intrusive PDH monitoring, with the interfaces:
1 x STM-16 (with SFP)
4 x STM-1/STM-4 (with SFP)
CM3568-A
SIMX4m, SDH interface module, cross-connect
and NE synchronization (SETS) functions, non-
intrusive PDH monitoring, with the interfaces:
4 x STM-1/STM-4 (with SFP)
CM3567-A
58 MA364 Rev. D2
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


Ethernet modules The following Ethernet modules are available for the Tellabs 6325 node.
SPIMX16m, SDH and PDH interface module,
cross-connect and NE synchronization (SETS)
functions, non-intrusive PDH monitoring, with
the interfaces:
1 x STM-1/STM-4/STM-16 (with SFP)
1 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-
ing external baluns.
CM3575
SPIMXm, SDH and PDH interface module, cross-
connect and NE synchronization (SETS) func-
tions, non-intrusive PDH monitoring, with the in-
terfaces:
2 x STM-1/STM-4 (with SFP)
21 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-
ing external baluns.
CM3574-A
SPIMX, SDH and PDH interface module, cross-
connect and NE synchronization (SETS) func-
tions, with the interfaces:
2 x STM-1/STM-4 (with SFP)
4 x 2 Mbit/s (E1) 120 Ohm
Note: 2 Mbit/s 75 ohm interfaces are available us-
ing external baluns.
CM3563
PIM3P, PDH interface module, with the interfac-
es:
6 x 34/45 Mbit/s (E3/DS3) 75 Ohm
CM3579
PIM1, PDH interface module, with the interfaces:
21 x 2 Mbit/s (E1) 120 Ohm
Note: 75 ohm interfaces are available using an ex-
ternal balun.
CM3566
Cover plate for traffic module position NS-0292
Description Item number
Description Item number
ETEX10S, Ethernet switching and mapping mod-
ule, with the interfaces:
4 x GbE (with SFP)
2 x FE (with SFP)
4 x FE (RJ-45)
CM3572
MA364 Rev. D2 59
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


WDM modules The following WDM modules are available for the Tellabs 6325 node.
EMAP, Ethernet mapping module, with the inter-
faces:
2 x FE (RJ-45)
2 x FE (RJ-45 or with SFP)
CM3571
Cover plate for traffic module position NS-0292
Description Item number
Description Item number
Optical multiplexer/demultiplexer
OM-C, 8 channel CWDM multiplexer and demul-
tiplexer module
CM3580C
OM-D, 8 channel DWDM multiplexer and de-
multiplexer module
CM3580D
Optical add/drop multiplexer
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1471 nm
CM3581C-471
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1491 nm
CM3581C-491
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1511 nm
CM3581C-511
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1531 nm
CM3581C-531
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1551 nm
CM3581C-551
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1571 nm
CM3581C-571
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1591 nm
CM3581C-591
OAD1-C, 1 channel CWDM optical add/drop
multiplexer module, 1611 nm
CM3581C-611
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 192.90 THz
CM3581D-290
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.00 THz
CM3581D-300
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.10 THz
CM3581D-310
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.20 THz
CM3581D-320
60 MA364 Rev. D2
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


Support modules The following support modules are available for the Tellabs 6325 node.
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.30 THz
CM3581D-330
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.40 THz
CM3581D-340
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.50 THz
CM3581D-350
OAD1-D, 1 channel DWDM optical add/drop
multiplexer module, 193.60 THz
CM3581D-360
Transponder/repeater/muxponder
TR4, 4 channel WDM transponder/repeater
module
Note: When using the TR4 or MP4 modules a
high frequency ferrite filter clamp on the power
supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission re-
quirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
CM3582
MP4, 4 channel WDM muxponder/transponder/
repeater module, NE synchronization (SETS)
function.
Note: When using the TR4 or MP4 modules a
high frequency ferrite filter clamp on the power
supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission re-
quirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
CM3585
Cover plate
Cover plate for traffic module position NS-0292
Description Item number
Description Item number
PS-DC module CM3561-A
AC/DC adapter CM3569
CMCC, Central management and communica-
tions control module
CM3564
FAN module CM3565
MA364 Rev. D2 61
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


2.4 Transceivers
Transceivers for SDH
interfaces
The following transceivers are available for the SDH interfaces of the Tellabs
6325 node.
Cover plate for PS-DC module position NS-0295
Description Item number
Description Item number
SDH
SDH transceiver, SFP, 1.0/2.3 coaxial connectors,
75 ohm. For the applications:
STM-1 electrical
TR-0021
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
S-1.1
FE
TR-0001
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
L-1.1
FE
TR-0002
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
L-1.2
FE
TR-0003
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
V-1.2
TR-0019-551
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
S-4.1
TR-0004
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
L-4.1
TR-0005
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
L-4.2
TR-0006
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
S-16.1
TR-0007
62 MA364 Rev. D2
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
L-16.1
TR-0008
SDH transceiver, SFP, LC connectors, single
mode fiber. For the applications:
L-16.2
TR-0009
Bi-directional SDH
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.2
100BASE-BX-D
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.1
100BASE-BX-U
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.2
1000BASE-BX-D
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.1
1000BASE-BX-U
TR-0026-U
SDH WDM
SDH/Ethernet CWDM transceivers, multirate,
available wavelengths are 1471 nm - 1611 nm
with 20 nm spacing, 1600 ps/nm, SFP, LC con-
nectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0020-xxx
Description Item number
MA364 Rev. D2 63
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


Transceivers for
Ethernet interfaces
The following transceivers are available for the Ethernet interfaces of the Tel-
labs 6325 node.
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC con-
nectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.
TR-0018-xxx
Description Item number
Description Item number
Fast Ethernet
Ethernet transceiver, SFP, RJ-45 connector,
shielded twisted pair. For the applications:
10/100BASE-T
TR-0027
Ethernet transceiver, SFP, LC connectors, multi
mode fiber. For the applications:
100BASE-FX
TR-0010
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:
100BASE-LX10
TR-0022
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
S-1.1
FE
TR-0001
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
L-1.1
FE
TR-0002
SDH/Ethernet transceiver, SFP, LC connectors,
single mode fiber. For the applications:
L-1.2
FE
TR-0003
Gigabit Ethernet
Ethernet transceiver, SFP, RJ-45 connector,
shielded twisted pair. For the applications:
1000BASE-T
TR-0013
64 MA364 Rev. D2
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


Ethernet/Fibre Channel transceiver, SFP, LC con-
nectors, multi mode fiber. For the applications:
1000BASE-SX
FC-100/200
TR-0011
Ethernet/Fibre Channel transceiver, SFP, LC con-
nectors, multi/single mode fiber. For the applica-
tions:
1000BASE-LX10
FC-100
TR-0012
Ethernet transceiver, SFP, LC connectors, single
mode fiber. For the applications:
1000BASE-ZX
TR-0023
Ethernet/Fibre Channel transceiver, multirate,
850 nm, SFP, LC connectors, multi mode fiber.
For the applications:
1000BASE-SX
FC-100/200/400
TR-0029
Bi-directional Ethernet
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.2
100BASE-BX-D
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.1
100BASE-BX-U
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.2
1000BASE-BX-D
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.1
1000BASE-BX-U
TR-0026-U
Description Item number
MA364 Rev. D2 65
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


Ethernet WDM
SDH/Ethernet CWDM transceivers, multirate,
available wavelengths are 1471 nm - 1611 nm
with 20 nm spacing, 1600 ps/nm, SFP, LC con-
nectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0020-xxx
Ethernet/Fibre Channel CWDM transceivers,
multirate, available wavelengths are 1471 nm -
1611 nm with 20 nm spacing, SFP, LC connectors,
single mode fiber. For the applications:
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0031-xxx
SDH/Ethernet DWDM transceivers, multirate,
available frequencies are 192.10 THz - 196.00 THz
with 100 GHz spacing, 2400 ps/nm, SFP, LC con-
nectors, single mode fiber. For the applications:
STM-1/4/16
FE/GbE
The xxx in the item number represents the last
three digits of the specific frequency e.g. 210 in
the frequency 192.10 THz.
TR-0018-xxx
Ethernet/Fibre Channel DWDM transceivers,
multirate, available frequencies are 192.90 THz -
193.60 THz with 100 GHz spacing, SFP, LC con-
nectors, single mode fiber. For the applications:
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific frequency e.g. 290 in
the frequency 192.90 THz.
TR-0032-xxx
Description Item number
66 MA364 Rev. D2
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


Transceivers for bi-
directional SDH/Ethernet
interfaces
The following transceivers are available for the bi-directional SDH/Ethernet
interfaces of the Tellabs 6325 node.
Transceivers for Fibre
Channel interfaces
The following transceivers are available for the Fibre Channel interfaces of the
Tellabs 6325 node.
Description Item number
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.2
100BASE-BX-D
TR-0025-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-1.1
100BASE-BX-U
TR-0025-U
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.2
1000BASE-BX-D
TR-0026-D
SDH/Ethernet transceiver, Bi-directional, SFP,
LC connectors, single mode fiber. For the applica-
tions:
S-4.1
1000BASE-BX-U
TR-0026-U
Description Item number
Fibre Channel
Ethernet/Fibre Channel transceiver, SFP, LC con-
nectors, multi mode fiber. For the applications:
1000BASE-SX
FC-100/200
TR-0011
Ethernet/Fibre Channel transceiver, SFP, LC con-
nectors, multi/single mode fiber. For the applica-
tions:
1000BASE-LX10
FC-100
TR-0012
MA364 Rev. D2 67
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


Ethernet/Fibre Channel transceiver, multirate,
850 nm, SFP, LC connectors, multi mode fiber.
For the applications:
1000BASE-SX
FC-100/200/400
TR-0029
Fibre Channel transceiver, multirate, 1310 nm,
SFP, LC connectors, single mode fiber. For the ap-
plications:
FC-100/200/400
TR-0030
Fibre Channel WDM
Ethernet/Fibre Channel CWDM transceivers,
multirate, available wavelengths are 1471 nm -
1611 nm with 20 nm spacing, SFP, LC connectors,
single mode fiber. For the applications:
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific wavelength e.g. 471 in
the wavelength 1471 nm.
TR-0031-xxx
Ethernet/Fibre Channel DWDM transceivers,
multirate, available frequencies are 192.90 THz -
193.60 THz with 100 GHz spacing, SFP, LC con-
nectors, single mode fiber. For the applications:
GbE
FC-100/200/400
The xxx in the item number represents the last
three digits of the specific frequency e.g. 290 in
the frequency 192.90 THz.
TR-0032-xxx
Description Item number
68 MA364 Rev. D2
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


2.5 Subrack Items
Subrack items The following subrack items are available for the Tellabs 6325 node.
2.6 Balun Items
Balun items The following balun items are available for the Tellabs 6325 node.
Description Item number
SC2 subrack, one rack unit (1RU) high, four slots
for traffic modules. The following items are deliv-
ered with the subrack:
Adaptation brackets for 19 inch rack
Adaptation brackets for ETSI rack
Cover plate for slot 6
Extraction tool kit (includes module reset tool)
M4 x 8 screw and washer to attach ground
wire
UC3560
Cover plate for empty slot 2-5 (position for traffic
module)
NS-0292
Cover plate for empty slot 8 (position for PS-DC
module)
NS-0295
Description Item number
120/75 ohm balun, 3 pole IDC (Krone) to BNC
connector, for 2 Mbit/s interface on PIM1 and
SPIMX modules. The balun provides only one
connection. So you need two WK-511B-KIT for a
2 Mbit/s interface, one for input and one for out-
put connections.
WK-511B-KIT
Balun panel kit BNC. Up to 42 baluns can be in-
stalled in the panel. The kit contains the following
items:
Balun panel for 19 inch rack
Balun panel for ETSI rack
Metal strap for fastening the cable shield
Screws for installing panel in a rack
NS-0299
MA364 Rev. D2 69
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


2.7 Cables
Traffic interface cables The following optical and electrical interface cables are available for the Tel-
labs 6325 node.
Description Item number
Optical single mode fiber cables, two fibers in one cable
2xLC to 2xLC single mode fiber cable, 0.3 m W-OF203/00.3
2xLC to 2xLC single mode fiber cable, 5 m W-OF203/05.0
2xLC to 2xLC single mode fiber cable, 10 m W-OF203/10.0
2xLC to 2xLC single mode fiber cable, 20 m W-OF203/20.0
2xLC to 2xFC/PC single mode fiber cable, 5 m W-OF204/05.0
2xLC to 2xFC/PC single mode fiber cable, 10 m W-OF204/10.0
2xLC to 2xFC/PC single mode fiber cable, 20 m W-OF204/20.0
2xLC to 2xSC single mode fiber cable, 5 m W-OF205/05.0
2xLC to 2xSC single mode fiber cable, 10 m W-OF205/10.0
2xLC to 2xSC single mode fiber cable, 20 m W-OF205/20.0
Optical multi mode fiber cables, two fibers in one cable
2xLC to 2xLC multi mode fiber cable, 5 m W-OF207/05.0
2xLC to 2xLC multi mode fiber cable, 10 m W-OF207/10.0
2xLC to 2xLC multi mode fiber cable, 20 m W-OF207/20.0
Electrical cables
1.0/2.3 to 1.0/2.3 coaxial cable, 5 m WK-482B-05.0-01
1.0/2.3 to 1.0/2.3 coaxial cable, 10 m WK-482B-10.0-01
1.0/2.3 to 1.0/2.3 coaxial cable, 20 m WK-482B-20.0-01
1.0/2.3 to BNC coaxial cable, 5 m WK-483B-05.0-01
1.0/2.3 to BNC coaxial cable, 10 m WK-483B-10.0-01
1.0/2.3 to BNC coaxial cable, 20 m WK-483B-20.0-01
1.0/2.3 to 1.6/5.6 coaxial cable, 5 m WK-484B-05.0-01
1.0/2.3 to 1.6/5.6 coaxial cable, 10 m WK-484B-10.0-01
1.0/2.3 to 1.6/5.6 coaxial cable, 20 m WK-484B-20.0-01
1.0/2.3 to open end coaxial cable, 20 m WK-497B-20.0-01
MDR to open ended cable, 120 ohm, 5 m WK-503Y-05.0-12
MDR to open ended cable, 120 ohm, 10 m WK-503Y-10.0-12
70 MA364 Rev. D2
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


Extraction tool for 1.0/2.3
coaxial cables
The following extraction tool for disconnecting coaxial cables provided with
1.0/2.3 connectors, is available for the Tellabs 6325 node.
Synchronization and
AUX alarm cable
The following synchronization and AUX alarm cable is available for the Tel-
labs 6325 node.
Management cable The following management cable is available for the Tellabs 6325 node. For
Ethernet interfaces, use standard STP Ethernet interface cables (RJ-45).
Power cable The following power cable is available for the Tellabs 6325 node.
EOW cable The following EOW cable is available for the Tellabs 6325 node.
Note: On the SPIMX module with 21 x 2 Mbit/s the EOW system is connected
with the 2 Mbit/s interface cable (WK-503Y-zz.z-12 - ref. Traffic inter-
MDR to open ended cable, 120 ohm, 20 m WK-503Y-20.0-12
RJ-45 to open ended cable, 120 ohm, 5 m WK-504Y-05.0-10
RJ-45 to open ended cable, 120 ohm, 10 m WK-504Y-10.0-10
RJ-45 to open ended cable, 120 ohm, 20 m WK-504Y-20.0-10
Description Item number
Description Item number
Extraction tool for coaxial cables (1.0/2.3) TOOL-H030
Description Item number
9 pole D-sub to open ended, 120 ohm, 3 m WK-502Y-03.0-01
Description Item number
Craft terminal interface cable, RJ-45 to 9 pole D-
sub, 3 m
WK-480X-03.0-01
Description Item number
3 pole Molex mini-fit to open ended, 2.6 m
Note: When using the TR4 or MP4 modules a
high frequency ferrite filter clamp on the power
supply cables are necessary in order to comply
with Class B of EN 55022 conducted emission re-
quirements. The ferrite filter clamp needs to have
an impedance of 700 ohm or better at 125 MHz
(e.g the Kitigawa SPC-10 part may be used). To
comply with Class A of EN 55022 the TR4/MP4
can be used without the ferrite filter clamp.
WK-500Z-02.6-01
MA364 Rev. D2 71
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


face cables on page 69). The open ended cable holds both the connec-
tions for the 2 Mbit/s interfaces and the EOW interface.
2.8 Embedded Software
Embedded software The following embedded software is available for the Tellabs 6325 node.
Cable description Item number
RJ-45 to 15 pole D-sub, 3 m WK-501Y-03.0-01
Description Item number
6325 ESW, FP1.3, CD-ROM SW6325-0013M200
72 MA364 Rev. D2
Tellabs

6325 Edge Node 2 Ordering Information for Tellabs 6325 Node


Tellabs

6325 Edge Node Index


MA364 Rev. D2 73
Index
Numerics
6325 items 11
A
Abbreviations 9
AC/DC adapter 11
Alarm cable
item number 70
B
Balun
Item number 68
Selecting 24
Basic Units 11
Item numbers 56
C
Cables
Item numbers 69
selecting 49
selecting alarm 52
selecting EOW 53
selecting for SDH/PDH interfaces 50
selecting management 52
selecting power 53
selecting synchronization 52
type of 49
CMCC 11
Coaxial cable extraction tool 70
Configuration and Ordering Guide
Prerequisite for using 9
Structure 9
Configuring a Tellabs 6325 Node 13
Basic Units 15
Dedicated Units 14
Subrack and Modules 17
D
DC/DC 11
Dedicated Units 11
Item numbers 55
Selecting 14
Document structure 9
E
EMAP 13
Embedded Software
Item number 71
selecting 53
ETEX10S 13
External balun
Selecting 24
Extraction tool for coaxial cables 70
F
FAN 12
I
Interconnecting nodes 28
Items 11
M
Management cable
Item number 70
MP4 13
O
OAD1-C 13
OAD1-D 13
OM-C 13
OM-D 13
Optical Amplifiers 49
P
PIM1 12
PIM3P 12
Power cable
Item number 70
Prerequisitefor using this guide 9
Product Release 9
Product version 9
PS-DC 11
S
SC2 11
Selecting
Cables 49
Embedded software 53
External balun 24
Support modules 18
Traffic modules 20, 29
Transceivers 40
Transceivers for bi-directional interfaces 47
Transceivers for EMAP module and
Tellabs

6325 Edge Node Index


74 MA364 Rev. D2
dedicated unit 47
Transceivers for ETEX10S module 44
Transceivers for Ethernet interfaces 44
Transceivers for Fibre Channel interfaces 48
Transceivers for SDH interfaces 40
Transceivers for SIMX and SPIMX modules
and dedicated units 40
Transceivers for STM-1 interfaces 41
Transceivers for STM-16 interfaces 41
Transceivers for STM-4 interfaces 41
SIMX16m 12
SIMX4m 12
Software
Item number 71
SPIMX 12
SPIMX16m 12
SPIMXm 12
Subrack 11
Items 68
Support modules
item numbers 60
Selecting 18
Synchronization cable
item number 70
T
Tellabs 6325 items 11
TR4 13
Traffic modules
Item numbers 57, 58, 59
Selecting 20, 29
Transceivers
Bi-directional interfaces 47
Ethernet interfaces 44
Fibre Channel interfaces 48
Item numbers 61, 63, 66
SDH interfaces 40
Selecting 40, 44, 47
U
Using optical amplifiers 49