Anda di halaman 1dari 12

Argon-enhanced electrosurgery

N
E
W
2
The Nelson Beamer: Teamwork is its strength
The Nelson Beamer is
an innovative device
for controlled Argon
plasma coagulation.
Nelson stands for
New Electrosurgical
Solutions and
constitutes a new
generation of
Aesculap devices in the
crme de la crme
of electrosurgery.
Argon-enhanced electrosurgery
Argon plasma coagulation and argon plasma cutting are the
ideal complement to electrosurgery. Innovative safety and per-
formance functions, as well as a precise and easy-to-regulate
power supply, optimize argon-enhanced electrosurgery.
Argon plasma coagulation is a monopolar procedure involving
the noncontact application of electrical current to tissue with
the aid of ionized argon gas. This technology is now widely used
in both endoscopic and open surgery.
Indications
General surgery Liver surgery Gynecology
Plastic and reconstructive surgery E.N.T.
Cardiac and thoracic surgery Bronchoscopy
Laparoscopy and pelviscopy Gastroenterology
The Nelson Beamer is the ideal complement to the entire family
of Aesculap electrosurgery units.
Once a sufficiently high level of voltage has been achieved and
the gap between the electrode and tissue is narrow enough, a
conductive electrical field - the argon plasma - is established
between the electrode and the tissue. The argon plasma then
acts as a conduit for the electrosurgical current that flows
between the electrode and the tissue.
3
The Nelson Beamer delivers optimal coagulation of
larger areas of diffuse bleeding.
No tissue adherence
Argon plasma coagulation is performed without touching the
tissue. This prevents tissues from sticking to active electrodes.
Coagulation is complete and evenly distributed
Whats special about argon-enhanced coagulation is that the
stream of argon plasma is distributed not only in a straight line
but can also be applied laterally and at an angle.
Surfaces that have already been coagulated manifest a high le-
vel of resistance; bleeding or insufficiently coagulated surfaces
have low resistance. The argon plasma flow automatically sear-
ches for the least resistant tissue areas within the application
region.
Tissue-sparing procedure with less blood loss
As an inert gas, argon creates a protective gas atmosphere,
thereby preventing oxygen from infiltrating the coagulation site.
The tissue surface in argon coagulation is more flexible and less
necrotic than that of conventional spray coagulation (up to a
maximum of 3 mm). The result: more reliable tissue closure and
enhanced wound healing.
Minimal smoke and odour
In endoscopic applications, smoke generation should be kept to
a minimum. Minimal smell put less strain on O.R. personnel,
particularly during long operations.
Advantages of the Nelson Beamer
4
The Nelson Beamers safety features
Selftest
After being switched on, the Argon control unit runs a
selftest during which the operational components, micro-
processor, hardware functions and warning signal are
checked.
Continuous function monitoring
While the device is operating, all relevant functions and
signals are checked at frequent intervals, thereby ensuring
optimal safety.
Gas pressure monitoring
In endoscopic procedures, argon gas increases the intra-
abdominal pressure. In order to minimize the risk of emphysema,
the Nelson Beamer continuously checks the intraabdominal
pressure (at the distal end of the electrode) that is set on the
unit. This function is of particular relevance with insufflation
devices that do not have an automatic gas release function.
At Aesculap we put
safety first.
Continuous
monitoring of all
key parameters by
the device ensures
optimal patient
safety.
Monitoring gas level
The level of gas in the argon bottle is indicated both visually
and in percentage points. If pressure in the argon gas bottle
decreases to less than 30 bar (15 percent of the remaining gas),
a warning signal sounds and the color of the bottle icon chan-
ges from green to red.
Gas flow individually programmable
Gas flow can be set separately for cut/coag in order to meet
specific requirements. The desired gas flow rate is set by
pressing a key on the device, and is monitored continually
while the device is in operation.
5
Documentation of error codes
When the Nelson electrosurgical device and
Nelson Beamer are used together, errors in the
Nelson Beamer are automatically saved in a
memory. This promotes rapid evaluation of the
sources of errors.
6
The Nelson Beamers comfort features
Saving data
The argon control unit is outfitted with seven
different memory locations. Memory location 1
(GEN-SURG) contains the standard values for
the application of rigid electrodes. Memory lo-
cation 2 (ENDO) is intended for use with en-
doscopic procedures that employ flexible pro-
bes. The other memory locations can be pro-
grammed individually and saved under a freely
selectable name.
Measurement of gas consumption
The quantity of gas consumed is displayed as a
digital value in liters. This digital value can be
reset at any time (e.g. in order to measure gas
consumption per operation).
CIDS allows you to see
everything at
a glance!
Never before has any
Aesculap information
system been easier to
understand. The display
changes according to
application. In each case,
the active output can be
clearly discerned thanks to
the heightened contrast of
the card displayed
on the screen.
CIDS (Colour Information Display System)
The Nelson Beamer is equipped with the unique colour
information display system (CIDS). All important information is
unambiguously and clearly displayed on a central information
display.
7
Automatic instrument recognition
The Aesculap electrosurgical device Nelson deluxe recognizes
coded, connected instruments automatically and (likewise auto-
matically) sets all predefined parameters. The Nelson Beamer
then receives the necessary information via the interface cable
and sets the corresponding parameters on its side.
Twisted cables are a thing of the past
The gas tube can be attached without twisting. It is tightened
down at the device with a locking wheel.
Unobstructed view of the colour display
The optimal height of the equipment trolley (which was
especially designed for the Nelson family of products) allows
for a direct view of the color display with optimal contrast.
Communication
The Nelson Deluxe and Nelson Beamer electrosurgery devices
communicate with each other via an intelligent CAN bus
interface.
Generous gas capacity
The unique design of the (optional) equipment trolley allows
the provision of two 10-liter bottles of argon gas. This reduces
the frequency of bottle changes. Nelson Beamer can also be
connected to the main gas supply.
8
GN 370 Argon control unit Nelson Beamer
GN 371 Argon bottle, 10 liters, empty (for Germany,
Austria, Switzerland, France, Portugal,
Spain and Greece)
GN 374 Membrane filter, 0.2 m, sterile (50 pieces)
GN 375 CAN bus connecting cable for the Nelson
Beamer and Nelson Deluxe
PV 950 Equipment trolley for the Nelson Beamer
and electrosurgery devices
PV 951 R Wire basket for equipment trolley PV950
GN 090830 Connecting cable for Nelson beamer and
electrosurgery combination devices GN 300,
GN 350 and GN 360
Rigid electrodes
GN 380 Argon handle, 2 keys cut/coag, cable 3.5 m
GN 382 R Argon coagulation electrode 25 mm long
GN 383 R Argon coagulation electrode 100 mm long
GN 384 R Argon coagulation electrode 320 mm long
GN 385 R Argon needle electrode 40 mm long
GN 386 R Argon needle electrode 115 mm long
GN 387 R Argon lancet electrode 40 mm long
GN 388 R Argon lancet electrode 115 mm long
Flexible argon probes
GN 390 Connecting cable for argon probes, 2.5 m
GN 392 Flexible argon probe, GIT 2.3 mm 2.2 m
GN 393 Flexible argon probe, GIT 3.2 mm 2.2 m
GN 394 Flexible argon probe, TBS 1.5 mm. 1.5 m
GN 395 Flexible argon probe, TBS 2.3 mm. 1.0 m
Pressure-reducing valves
GN 372 Pressure-reducing valve in accordance with
DIN 477 no. 6 (Germany, Austria, Switzerland,
France, Portugal, Spain and Greece)
GN 373 Pressure-reducing valve in accordance with
DIN 477 no. 10 (the Netherlands, Denmark,
Sweden, Norway)
GN 376 Pressure-reducing valve in accordance with
CGA no. 580 (Italy)
GN 377 Pressure-reducing valve in accordance with
BS 341 no. 3 (Australia, Malaysia, England)
GN 378 Pressure-reducing valve in accordance with
UNI 4412 (Mexico, Thailand, U.S.A, South America)
The Nelson Beamer argon device
and accessories
9
10
The Aesculap service package
Diagnosing malfunctions
Your ATS team is comprised exclusively of
highly experienced specialized technicians.
When your device or instrument is received, it
is first thoroughly examined and subsequently
undergoes a number of functionality tests.
The result: a well-founded diagnosis of the
malfunction.
Cost-efficiency review
The technician compares the cost of
replacement with the estimated repair cost.
If the repair cost exceeds two-thirds of the
replacement cost, a repair price quote is
automatically sent to you.
Repairs
After our value-maintaining and cost-
efficient repair has been performed, your
devices and instruments will again be in
first class condition. Your ATS team uses
only manufacturer-tested replacement
parts.
All repairs are guaranteed for 1 year.
Return shipping
Your product is returned to you immediately
upon being repaired.
AESCULAP Technical Service is
certified in conformance with
ISO9001/EN 46001.
Our ATS specialist technicians apply their
long years of experience to finding just the
right solution to your technical problems.
Hotline
Often a problem can be solved over the phone.
The Hotline is available to you, Monday-Friday
from 7 a.m. to 8 p.m. (local time) for all
matters relating to repairs, sending of devices,
loan devices, training etc.
Give us a call. Phone:
+49 800 100 17 56
Surgeons who perform procedures in a
concentrated fashion and who frequently
do so under emergency conditions need
optimal functionality in the entire operative
system.
This all systems go posture is the lynchpin
of all technical equipment, from cameras to
lenses, up to and including insufflators and
electrosurgical devices.
Aesculap creates the optimal conditions for
this with its winning team of qualified medical
and service technicians.
Aesculap Technical Service (ATS) is your
expert partner when it comes to maintaining
the value of your equipment, as well as repair
and reconditioning.
Tailor-made and pragmatic service concepts
ensure delivery of fast, intelligent and cost-
effective repair and reconditioning. This is
of particular importance to you in a time of
shrinking resources and for us, its a sine
qua non.
Repairs
Expertise borne of over 130 years of
production experience
Repairs performed on devices from all
manufacturers
1 year warranty on all repairs
Loan devices
Loan devices provided to tide you over while
your product is being repaired.
Pick-up and delivery service
Logistical support for all products
requiring repair
You dont need to lift a finger
Personalized service
Maintenance
On-site testing and maintenance of your
devices at regular intervals.
Service contracts
Service from a single source
Service budgeting
Regular lump sum payments
1 year warranty on all repairs
Transparent service costs
Enhanced cost-efficiency
C 771
Nelson deluxe
GN 640
11
Specifications
Apart from top quality equip-
ment, HF attachments are also
an important prerequisite for a
successful O.R.
Aesculap offers an exceptionally
broad range of quality products
that is continuously optimized
and systematically expanded for
new indications.
Our goal is to offer a tailor-
made system solution for every
need. It is for this reason that
we offer a large selection of
disposable products in addition
to our reusable instruments.
For further information about
Aesculap HF attachments, please
ask for our special brochure
C-304-81.
C 306
Combi HF unit
GN 300
C 464
ArthroResector
GN 360
C 465
Jet irrigation
system GN 90
C 304
HF surgery
attachments
C 725
Modular
monopolar HF
Electrodes
C 478
Single use
patient plate
C 724
Single use
electrosurgical
pencil
Article number GN 370
Utility supply 100-240 V, 50/60 Hz

10%
Power consumption 0.7 A at 100 V
0.8 A at 120 V
0.4 A at 220 V
0.35 A at 240 V
Safety rating I
Gas inlet pressure 2.5 - 4.5 bar
Gas type Argon
Maximum gas outflow pressure 2.0 bar
Adjustable range of gas flow rate 0.1 l/min - 12.0 l/min
Weight 7.3 kg
Dimensions (W x H x D) 310 x 175 x 310 mm
Type of application component CF
EMV IEC 60601-1-2
Norm conformance IEC 60601-1
IEC 60601-2-2
Brochure No. C 776 02
All rights reserved. Technical alterations are possible. This leaflet may be used for no other purposes than offering, buying and selling of our products. No part may be copied or
reproduced in any form. In the case of misuse we retain the rights to recall our catalogues and pricelists and to take legal actions.
12.01/2.0/3
Germany
AESCULAP AG & CO. KG
Am Aesculap-Platz
78532 Tuttlingen/ Germany
Phone +49 (74 61) 95-0
Fax +49 (74 61) 95-26 00
http://www.aesculap.de
United Kingdom
B. Braun Medical Ltd.
Thorncliffe Park
GB-Sheffield S35 2PW
Phone +44 (114) 22590 00
Fax +44 (114) 2259111
http://www.bbraun.com