Anda di halaman 1dari 2

T

h
e

i
n
f
o
r
m
a
t
i
o
n

p
r
o
v
i
d
e
d

i
n

t
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

c
o
n
t
a
i
n
s

g
e
n
e
r
a
l

d
e
s
c
r
i
p
t
i
o
n
s

a
n
d
/
o
r

t
e
c
h
n
i
c
a
l

c
h
a
r
a
c
t
e
r
i
s
t
i
c
s

o
f

t
h
e

p
e
r
f
o
r
m
a
n
c
e

o
f

t
h
e

p
r
o
d
u
c
t
s

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
T
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

i
s

n
o
t

i
n
t
e
n
d
e
d

a
s

a

s
u
b
s
t
i
t
u
t
e

f
o
r

a
n
d

i
s

n
o
t

t
o

b
e

u
s
e
d

f
o
r

d
e
t
e
r
m
i
n
i
n
g

s
u
i
t
a
b
i
l
i
t
y

o
r

r
e
l
i
a
b
i
l
i
t
y

o
f

t
h
e
s
e

p
r
o
d
u
c
t
s

f
o
r

s
p
e
c
i
f
i
c

u
s
e
r

a
p
p
l
i
c
a
t
i
o
n
s
.
I
t

i
s

t
h
e

d
u
t
y

o
f

a
n
y

s
u
c
h

u
s
e
r

o
r

i
n
t
e
g
r
a
t
o
r

t
o

p
e
r
f
o
r
m

t
h
e

a
p
p
r
o
p
r
i
a
t
e

a
n
d

c
o
m
p
l
e
t
e

r
i
s
k

a
n
a
l
y
s
i
s
,

e
v
a
l
u
a
t
i
o
n

a
n
d

t
e
s
t
i
n
g

o
f

t
h
e

p
r
o
d
u
c
t
s

w
i
t
h

r
e
s
p
e
c
t

t
o

t
h
e

r
e
l
e
v
a
n
t

s
p
e
c
i
f
i
c

a
p
p
l
i
c
a
t
i
o
n

o
r

u
s
e

t
h
e
r
e
o
f
.
N
e
i
t
h
e
r

S
c
h
n
e
i
d
e
r

E
l
e
c
t
r
i
c

I
n
d
u
s
t
r
i
e
s

S
A
S

n
o
r

a
n
y

o
f

i
t
s

a
f
f
i
l
i
a
t
e
s

o
r

s
u
b
s
i
d
i
a
r
i
e
s

s
h
a
l
l

b
e

r
e
s
p
o
n
s
i
b
l
e

o
r

l
i
a
b
l
e

f
o
r

m
i
s
u
s
e

o
f

t
h
e

i
n
f
o
r
m
a
t
i
o
n

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
Mar 12, 2013
1
Product data sheet
Characteristics
LV432676
circuit breaker Compact NSX400F - Micrologic
2.3 - 400 A - 3 poles 3d
Main
Range of product NSX400...630
Product or component
type
Circuit breaker
Circuit breaker name Compact NSX400F
Device short name Compact NSX400F
Circuit breaker applica-
tion
Distribution
Poles description 3P
Protected poles de-
scription
3t
Network type AC
Network frequency 50/60 Hz
[In] rated current 400 A ( 40 C )
[Ui] rated insulation
voltage
800 V AC 50/60 Hz
[Uimp] rated impulse
withstand voltage
8 kV
[Ue] rated operational
voltage
690 V AC 50/60 Hz
Breaking capacity code F
Breaking capacity Icu 40 kA at 220/240 V AC 50/60 Hz conforming to
IEC 60947-2
Icu 36 kA at 380/415 V AC 50/60 Hz conforming to
IEC 60947-2
Icu 30 kA at 440 V AC 50/60 Hz conforming to IEC
60947-2
Icu 25 kA at 500 V AC 50/60 Hz conforming to IEC
60947-2
Icu 20 kA at 525 V AC 50/60 Hz conforming to IEC
60947-2
Icu 10 kA at 660/690 V AC 50/60 Hz conforming to
IEC 60947-2
85 kA at 240 V AC 50/60 Hz conforming to UL 508
40 kA at 240 V AC 50/60 Hz conforming to NEMA
AB1
35 kA at 480 V AC 50/60 Hz conforming to UL 508
30 kA at 480 V AC 50/60 Hz conforming to NEMA
AB1
20 kA at 600 V AC 50/60 Hz conforming to UL 508
[Ics] rated service
breaking capacity
Ics 40 kA 220/240 V AC 50/60 Hz conforming to IEC
60947-2
Ics 36 kA 380/415 V AC 50/60 Hz conforming to IEC
60947-2
Ics 30 kA 440 V AC 50/60 Hz conforming to IEC
60947-2
Ics 25 kA 500 V AC 50/60 Hz conforming to IEC
60947-2
Ics 10 kA 660/690 V AC 50/60 Hz conforming to IEC
60947-2
Ics 10 kA 525 V AC 50/60 Hz conforming to IEC
60947-2
Suitability for isolation Yes conforming to IEC 60947-2
Yes conforming to EN 60947-2
Utilisation category Category A
Trip unit name Micrologic 2.3
Trip unit technology Electronic
Trip unit protection
functions
LSoI
Trip unit rating 400 A ( 40 C )
2
Protection type Instantaneous short-circuit protection
Overload protection (long time)
Short time short-circuit protection
Pollution degree 3 conforming to IEC 60664-1
Complementary
Control type Toggle
Mounting mode Fixed
Mounting support Backplate
Upside connection Front
Downside connection Front
Mechanical durability 15000 cycles
Electrical durability 6000 cycles 690 V In/2 conforming to IEC 60947-2
6000 cycles 440 V In conforming to IEC 60947-2
3000 cycles 690 V In conforming to IEC 60947-2
12000 cycles 440 V In/2 conforming to IEC 60947-2
Connection pitch 45 mm
Local signalling LED 105 % Ir
LED 90 % Ir
LED ready
Long time pick-up adjstment type Ir Adjustable 9 settings
Long time pick-up adjustment range 0.9...1 x Io
Long time delay adjustment type Fixed
[Tr] long-time delay adjustment 16 s 6 x Ir
Thermal memory 20 minutes before and after tripping
Short-time pick-up adjustment type Isd Adjustable 9 settings
[Isd] short-time pick-up adjustment range 1.5...10 x Ir
Short-time delay adjustment type Fixed
Instantaneous pick-up adjustment type Ii Fixed
Instantaneous pick-up adjustment range 4800 A
Height 255 mm
Width 140 mm
Depth 110 mm
Product weight 6.05 kg
Environment
Electrical shock protection class Class II
Standards EN 60947-2
IEC 60947-2
NEMA AB1
UL 508
Product certifications CSA
UL
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -35...70 C
Ambient air temperature for storage -55...85 C
Offer Sustainability
Sustainable offer status Not Green Premium product
RoHS
Compliant - since 0819 - Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Product end of life instructions Need no specific recycling operations
Contractual warranty
Period 18 months

Anda mungkin juga menyukai