Testers DESCRIPTION The MI T200 i sone of the smallest i nsulati on testersavai lable on the market today. Wi th opti onsof one, two and three voltage test voltage i nstruments, the MI T200 i nstruments offer a range of safety and operati on features. The di splay offersa combi nati on of di gi tal readout and analog di splay, usi ng Megger spatented DART di splay technology, whi ch i ncludesthe benefi tsof an LCD di splay, such asrobust, clear and accurate measurement, wi th an analog poi nter response for evaluati ng ci rcui t charge and di scharge characteri sti cs. The i nstrument housi ng i si n tough ABS, desi gned to wi th- stand the ri goursof hard use, and i ssmall enough to drop i nto your pocket when not i n use. Batteryrequi rementsare 6 AA batteri esof ei ther standard alkali ne or ni ckel metal hydri de ( Ni MH) rechargeable type. A low battery warni ng i ndi cator gi vesadvanced warni ng of exhausted batteri es. Continuity testing Automati c conti nui ty testi ng i sperformed at 200 mA to ensure compli ance wi th i nternati onal requi rements. There i s no need to pressthe test button. All i nstrumentswi ll measure up to 100 on conti nui ty, of whi ch 0-10 i sperformed at greater than 200 mA to meet i nternati onal electri cal testi ng requi rements. Lead null i spossi ble up to 9.99 of test lead resi stance, ensuri ng the abi li ty to null fused test leadsaswell as| standard leads. Continuity buzzer A conti nui ty buzzer provi desa meansof rapi d cable testi ng and ci rcui t i denti fi cati on, wi th voltage protecti on should you acci dentally touch a li ve ci rcui t. The buzzer operatesat a 2 threshold. Insulation testing The i nstrumentsoffer four confi gurati onsasdetai led on page 2, provi di ng an i deal soluti on to most low voltage i nsulati on testi ng appli cati ons. I nsulati on testi ng i spossi ble up to 1000 M on all ranges. Auto di scharge ensuresall ci rcui tsare safely di scharged after testi ng. 1000 V i nsulati on test rangeshave a hi gh voltage warni ng pri or to test voltage bei ng appli ed. I Insulation testing to 1000 M I Continuity testing at 200 mA down to 0.01 I Live circuit warning (voltage display) and test inhibit I Digital/Analog display I Alkaline or rechargeable batteries I 10C to +55C operating temperature I CATIII 600 V I Conf orms to EN61557-1 MIT200 Series Digital/Analog Insulation and Continuity Testers FEATURES AND BENEFITS SUMMARY I Meetsthe i nternati onal EN61557 requi rementsof the rated test voltage i nto a 1 mA load. I Di gi tal di splay of i nsulati on measurement up to 1000 M on a logari thmi c analogue arc and a di gi tal di splay. I Conti nui ty range has0,01 resoluti on and a short ci rcui t current i n excessof 200 mA. I Automati c conti nui ty testi ng leavesboth handsfree. No need to pressthe test button. I Automati c power-off i f left unattended reduced wasted battery li fe. I Automati c voltage detecti on avoi dsacci dental contact wi th li ve ci rcui ts. I Test lead zero allowscompensati on for test lead resi stance. I Buzzer range operatesat < 2 . Saf ety Every Megger i nstrument i sdesi gned wi th safety asi ts pri mary objecti ve. All i nstrumentsmeet or exceed the requi rementsof safety di recti ve I EC 61010 and EN61557 for i nsulati on and conti nui ty testi ng.. Def ault f ault meter A bui lt-i n voltmeter automati cally swi tchesi n when the i nstrument i sconnected to a ci rcui t wi th an AC or DC voltage greater than 25 V. Insulation Test inhibit Ci rcui tsi n excessof 25 V wi ll generate a voltage warni ng. Ci rcui tsover 50 V wi ll i nhi bi t testi ng of the i nsulati on, protecti ng the operator and the i nstrument from i njury or damage. 600V CATIII The MI T200 seri eshasbeen desi gned for use on appli cati onsup to 600 V CATI I I . APPLICATIONS The MI T200 seri eswi ll fi nd appli cati onsi n electri cal contracti ng, both on domesti c and i ndustri al systems, as well assi te mai ntenance and servi ce departments. The MI T200 seri esof i nsulati on and conti nui ty testersare i deal for testi ng transformers, motors, generators swi tchgear, panel bui ldi ng, domesti c appli ances, power toolsetc., aswell asfi xed electri cal wi ri ng systems. Thei r small si ze and li ght wei ght make them i deal for those engi neersthat need to carry them for extended peri ods. All i nstrumentsmeet the requi rementsof most I nternati onal Standardsi ncludi ng VDE0413 Part 1 and BS7671 ( the 16th Edi ti on of the I EE Wi ri ng Regulati ons) . MIT200 Series Digital/Analog Insulation and Continuity Testers MIT200 OPTIONS Insulation testing 250 V I I 500 V I I I 1000 V I I 1000 M range I I I I Auto-rangi ng I I I I Auto di scharge I I I I Test i nhi bi t I I I I Li ve ci rcui t voltage di splay I I I I Continuity testing Conti nui ty @ > 200 mA I I I I Conti nui ty to 0.01 I I I I Test lead null ( 9.99 ) I I I I Automati c conti nui ty test I I I I Conti nui ty buzzer wi th 2 threshold I I I I Default voltswarni ng I I I I General Di gi tal di splay + arc I I I I Batterycondi ti on I I I I Auto power down I I I I Tough carry case I I I I Test leads I I I I CATI I I 600 V I I I I Environmental O perati on temperature -10C to + 55C Storage temperature -20C to + 65C I P rati ng I P40 M I T 2 0 0 M I T 2 1 0 M I T 2 2 0 M I T 2 3 0 MIT200 Series Digital/Analog Insulation and Continuity Testers SPECIFICATIONS Insulation ranges Nominal test voltage: 1000 V, 500 V, 250 V ( d.c.) Measuring range 10 k -1000 M on all ranges Terminal voltage on open circuit (d.c.): -0% + 25% of rated voltage Short circuit current: 205 mA + 10 mA 5 mA Test current on load: > 1 mA at mi ni mum passvaluesof i nsulati on asspeci fi ed i n BS7671, HD384, I EC364 and VDE0413 part 1 Accuracy (at 20 C) MIT200, 210, 220, 230: 3% of readi ng 2 di gi tsup to 10 M 5% of readi ng 2 di gi tsup to 100 M 30% of readi ng up to 1000 M Terminal characteristics Continuity ranges Measuring range: 0,01 -100,0 ( 0 -50 on analogue scale) Open circuit voltage: 5 V 1 V Short circuit current: 205 mA, 5 mA ( 0-10 ) > 20 mA ( 0 -100 ) Accuracy (at 20 C) MIT200, 210, 220, 230: 0,01 to 9,99 3% 2 di gi ts 10,0 to 99,9 5% 2 di gi ts Zero offset adjust: MIT200, 210, 220, 230: 0 to 9,99 Continuity buzzer MIT200, 210, 220, 230: O peratesat < 2 Def ault voltmeter MIT200, 210, 220,230: > 25 V ac or dc. i sappli ed di splay wi ll operate asa voltmeter. Test inhibit I f more than 50 voltsi sdetected, testi ng wi ll be i nhi bi ted. Range: 25 V to 600 V @ 50/60 Hz & dc Accuracy: 25 V to 450 V ac/dc 1% 1 di gi t 450 V to 600 V ac 2% 1 di gi t Auto power down Auto power down operatesafter 10 mi nutesi f left i n standby mode. Temperature and humidity Operating range: -10C to + 55C ( 14F to 130F) Operating humidity: 93% R.H. at + 40C max. ( 93% R.H. at 104F) Storage range: -25C to + 65C ( -13F to 150F) Environmental protection: I P40 Fuses Terminals: 500 mA ( F) 600 V, 32 x 6 mm Cerami c HBC 50 kA mi ni mum. Di splay showsi f fuse i sruptured. Saf ety Meetsthe requi rementsof EN61010-1 Cat I I I 600V phase to earth. Automatic discharge After an i nsulati on test the i tem under test wi ll be di scharged automati cally. Any voltage present wi ll be i ndi cated on the di splay so that the di scharge can be moni tored. Power supply Battery 6 x 1,5 V cellsI EC LR6 type( AA alkali ne) . Rechargeable Ni MH cellsmay be used. Battery condi ti on i sconstantly shown on the di splay asa four- secti on bar-graph. Battery lif e 3000 consecuti ve tests( 5 secondsper test) on any test usi ng 2Ah batteri es. Weight All units: 550gms approx. ( 1.2lbs) Dimensions All units: 195 x 98 x 40mm ( 7.7 x 3.9 x 1.6 i nches) E.M.C I n accordance wi th I EC61326-1 UK Archcliff e Road Dover CT17 9EN England T +44 (0) 1304 502101 F +44 (0) 1304 207342 UNITED STATES 4271 Bronze Way Dallas TX 75237-1088 USA T 800 723 2861 (USA only) T +1 214 333 3201 F +1 214 331 7399 OTHER TECHNICAL SALES OFFICES Norristown USA, Sydney AUSTRALIA, Toronto CANADA, Trappes FRANCE, Kingdom of BAHRAIN, Mumbai INDIA, Johannesburg SOUTHAFRICA and Conjure THAILAND. Registered to ISO 9001:2000 Cert. no. Q 09290 Registered to ISO 14001-1996 Cert. no. EMS 61597 MIT200_DS_us_V06 www.megger.com Megger is a registered trademark MIT200 Series Digital/Analog Insulation and Continuity Testers ORDERING INFORMATION Item (Qty) Order No. 250 V/500 V Insulation and continuity tester MIT220-EN 250 V/500 V/1000 V Insulation and continuity tester MIT230-EN Non UK instruments 500 V Insulation and continuity tester MIT200-EN 1000 V Insulation and continuity tester MIT210-EN Included accessories Lead set with prods and clips 6220-779 Carry case 5410-419 Item (Qty) Order No. Optional accessories Replacement lead set 6220-779 Fused lead set 6220-789 Removable protective holster 5410-346 Carry pouch 6220-773