PS Infracon, Bangalore Sr. No ITEM BOQ FOR ELECTRICIAL WORKS PREAMBLE The description of an item shall be deemed to include all preambles, headings, sub-headings and references to other documents. The detailed description of work and materials, given in the Specification are not necessarily repeated in the Bill of Quantities. The dimensions shown in the drawings shall have to be verified by the contractor at site before execution of the items and necessary allowance's) have to be made as per the actual dimensions available at site. The contractor should refer to the detailed drawings for details. All the rates so quoted should be inclusive of all hardware. In case of discrepancy between drawing and Bill of Quantity the drawing supersedes, unless specifically mentioned in the BOQ. Items of work provided in this schedule but not covered in the specifications shall be executed strictly as per instructions of the engineer-in-charge(PSI) Unless specifically mentioned otherwise in the contract, the tenderer shall quote for the finished items and shall provide for the complete cost towards labour, materials, plant and machinery, operational costs, levies, taxes, transport, repairs, rectification, maintenance till handing over, revenue expenses, contingencies, overheads, profits and all incidental items not specifically mentioned but reasonably implied and necessary to complete the works according to the contract. The quantities of the various items mentioned in the schedule in the schedule of items and may vary up to any extent or be deleted altogether. The quoted rates of each item shall remain firm for all works and quantities. The contractor, in his own interest, should get an indication of the probable extent of the work to be executed under any particular item in this schedule, before undertaking any preliminary and enabling work or purchasing bought out components related to the work. Rates shall be quoted both in figures and in words in clear legible writing. No overwriting is allowed. All scoring and cancellations should be countersigned by the tenderer. In case of illegibility, the interpretation of the engineer shall be final. All entries shall be in English language. Engineer-in-charge's (PSI) decision shall be final and binding on the contractor regarding clarifications of items in this schedule with respect to the other sections of the Contract. It may be noted that the total work or any part / parts of the same may be awarded as mentioned in this schedule of items. The cost quoted to include providing general house-keeping support for the entire site inclusive of all dedicated labour and supervisory personnel at all times of work, across the entire facility. Cost to include all equipments, consumables, protective and safety measures at site and providing necessary amenities like Water supply for drinking water, dedicated Human recourses for the sameand other office facilities as instructed by Engineers (PSI) All construction workers will be provided with proper PPE's without which the Engineer (PSI) has to right to send the worker away until proper PPE's are present To prevent dust entry from construction site to finished areas demarking with barricades has to be used INTERNAL WIRING AND POWER POINTS Light Point (Primary point): Supply and wiring for light point with 2 runs of1.5 sq.mm650V grade PVC insulated Copper conductor multi strand wires along with one run PS Infracon, Bangalore DESCRIPTION OF ITEMS of 1.5sq.mm copper earth wire in 25mm dia heavy guage PVC conduit concealed in wall/ Ceiling including supply and fixing of 5Amp modular type switch In suitable anodised GI box complete with fixing 3 way Ceiling rose including interconnections as required PVC pipes :- VIP/PRECISION/NELCO, Wires:-Polycab, Switches and Modlar boxes Anchor Roma, End termination lugs:- DOWELL/3D. Glands:- SUNIL/HMI/BRACO/COMET Secondary light point : Same as Item 1.1 But point looped from Primary point. Same As Above Exhaust fan point Supply and wiring same as item 1.1 above but for Exhaust fan point Same As Above 5A Switch socket outlet (Independant type) Supply and wiring same as item 1.1 above but for 5A2/3 pin socket outlet with switch including the supply of the same Switches and Modlar boxes:- Anchor Roma, 5Amp. Switch socket outlet: (Dependant) Supply and fixing of 5Amp.2/3 pin combined switch socket outlet in lighting control board including interconnections. Switches and Modlar boxes:- Anchor Roma, 15A Socket point : Supply and fixing of 15Amp. 5/15A Modular switch & Socket in suitable anodised box Switches and Modlar boxes:- Anchor Roma, Supply and Installation of 3No's 6 Amps 5 pin sockets controlled by 16Amps switch fixed in appropriate factory made boxes excluding wiring from distribution board to point . Switches and Modlar boxes:- Anchor Roma, TOTAL OF INTERNAL WIRING AND POWER POINTS RUN OF SUBMAINS MAINS: Supply and wiring with 2runs of 2.5 sq.mm copper conductor wires with 1run of 1.5sq.mm copper earth wire from DB to switch boards as circuit wires in 2mm thick PVC conduits Supply and wiring with 2runs of 4sq.mm copper conductor wires with 1run of 2.5sq.mm copper earth wire from DB to15A/20A sockets in 2mm thick PVC conduits Supply and wiring with 4runs of 6sq.mm copper conductor wires with 2runs of 4sq.mm copper earth wire from Panel to DBs as circuit wires in 2mm thick PVC conduits TOTAL OF SUBMAINS MAINS: DISTRIBUTION BOARDS: Supply and installation of following size TPN MCB double door distribution boards with CRCA sheet steel enclosure dust and vermin protected rated for 440V, 50HZ AC supply operation inclusive of busbar of suitable capacity, Neutral link with required outgoings DIN bar, and earthing terminals including MCBs conforming to IS:8828. The DBs are to fixed in flush with the wall including Incomer ELCB and all fixing materials complete as required. ELDB shall conform to IS : 12640. The rate shall be inclusive ofwiring adopter boxes around the DB & the dummies required in the DB. 6 way TPNMCB DB with 12nos 6A/16A - Lighting SPMCBs as outgoings and 25A DP MCBs -3Nos and 4pole 40Amp,100mA,sensitivity ELCB as incomer. 8way TPNMCB DB with 18nos.6A/16A - Rp-4, Ups-1, SPMCBs as out goings and 25A DP MCBs -3Nos and 4pole 63Amp,100mA sensitivity ELCB as incomer For along with circuit wiring pipe only come to up to DB 8 way TPNMCB Vertical DB with 24nos 6-20A SP MCBs as outgoings and 63A FP 100mA ELCB as incomer. Hume 1 Phase 8 way DB for Emergency Lighting - Emergence Incomer: 1 No. 32A DP ELMCB Outgoings: 6 Nos. 6/16A SP MCBs. For along with circuit wiring pipe only come to up to DB MV PANELS Supply, Installation, Testing and Commissioning of 3 phase 415V 4 wire Free Standing Floor mounted MV panel made out of 14 SWG CRCA sheet after seventank process and painting with Epoxy powder coating including all switchgear as detailed below. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A per Sq.mm) supported withDMC/ SMC barriers and colour coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit with standing capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be mounted on channels grouted to the floor including all materials. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. All feeders shall be earthed with 2 GI flats of adequate size to the main earth bus of 50x6mm GI flat. The size of all Panel Mounting Meters shall be 96X96mm.The Panels shall be mounted on U channels including supply and fixing of the same.All MCCBs shall have 80-100% thermal setting plug. fuses shall be provided for Control purposes (All Panels Shall be Extendable type). All the incomer breaker shall be provided with 2nos NO-NC contacts.(All MCBs shall be with 'C' curve) Main Panel Incoming : 200A 25KA TP MCCB with thermal setting plug & Earth leakage relay (300mA - 3000mA) with resincast CBCT 1set Busbars : 250A TPN Aluminium Busbars - 1Set Outgoings : 100A 16KA FP MCCBs - 3Nos 63A 10KA FP MCBs ('C'-curve)- 3Nos 40A 10KA FP MCBs ('C'-curve)- 4Nos 20A 10KA FP MCBs ('C'-curve) 2Nos i) 0 - 500V Voltmeter with Selector switch 1set ii) 0-200A Ammeter with cast resin CTs and selector switch-1set iii) LED type Phase indication lamps with individual MCB control and toggle switches -1set TOTAL OF DISTRIBUTION BOARDA AND PANELS LT CABLE WORK Supply, Instalaltion, Testing & Commissioning of XLPE insulated sheathed steel tape armoured Aluminium UG cable with pvc outer sheathing 1.1 KV class . The cable shall be either laid on existing cable trays or in existing trench. The cable shall be tied with nylon ties on the cable tray and a overlapping 25x3mm GI strip shall be fixed to the cable tray. The cost of the nylon tie and overlapping GI strip shall be included in the cost of installation. (Not to include the cost of cable trays/trench). This cable shall be directly laid in ground including escavation back filling of earth complete Armoured Aluminium XLPE Cable: 3.5 Core, 120 Sqmm cable. 3.5 Core, 95 Sqmm cable. 4 Core, 25 Sqmm cable. 4 Core, 16 Sqmm cable. 3 Core, 6 Sqmm copper armoured cable. 4 Core, 4 Sqmm copper armoured cable. Supply, Installation, Testing & Commissioning of End terminations for following cables using double compression tinned brass glands with bronze lugs using hydraulic crimping tools complete. Aluminium cables: 3.5 Core, 120 Sqmm 3.5 Core, 95 Sqmm 4 Core, 25 Sqmm 4 Core, 16 Sqmm 3 Core, 6 Sqmm copper armoured cable 4 Core, 4 Sqmm copper armoured cable TOTAL FOR LT CABLES Light Fixtures Supply, installation, testing & commissioning of following type LED light fixture assemblies: Supply and installation - Wipro Cat. Ref. No :LC20-036-XXX-WH-XX or Equivalent. Supply and installation - Wipro Cat. Ref. No :LM17-291-XXX-50-XX or Equivalent. Exhaust Fans Supply and Installation of Exhaust fans of following size sweep with gravity louvres shutters including all accessories / Installation materials required. 305mm Sweep TOTAL OF LIGHT FIXTURES Floor Raceway Supply and fixing of 2mm thick Aluminium Floor Raceways of the following sizes in the floor with cutting the floor using floor cutting machine etc., 100x 40mm 2mm thick Aluminium Box section as raceway. Supply and fixing of (for Aluminium Floor Raceway)100x100x50mm deep MS boxes in floor with top removable cover made out of 18SWG MS Sheet including Painting with 2 coats of anti corrosive paint and 2 coats of synthetic enamel paint etc complete as required. TOTAL OF RACEWAYS DATA / TELEPHONE & TV DISTRIBUTION SYSTEM Supply & Installation of moulded type telephone /data IC outlets 3 pin socket in factory made 16Swg GI box to size 3"x3"x3" and fixed at 2' 6" ht & at 1' 6" other areas from finished floor level. Supply and Installation of 25mm dia pvc conduit with 16Swg GI fish wire from Telephone / data point to Telephone /data draw box in shaft. Supply and Installation of 19mm dia pvc conduit with 14 Swg GI fish wire from telephone/data draw box in each floor to main tag block in Ground floor. Supply and Installation of CAT 6 / AT and T drawn in existing conduit from telephone/data point to tag block. TOTAL DATA / TELEPHONE & TV DISTRIBUTION SYSTEM EARTHING SYSTEM Supply & Installation of Earth Electrode as per approval of EB and the Earth electrodes shall be 40mm dia 3mm thick GI long confirming to IS 1249, the entire earth installation shall be as per Indian STD code of practice IS 3043 with GI plate 2'x2'x1/4" & funnel arrangement. Supply, installation, Testing and commissioning of Copper plate earth station as per IS 3043 complete with 600 x 600 x 3mm Copper plate, GI watering funnel, 450 mm x 450mm CI frame and CI cover, 300mm brick masonary chamber etc. complete. EARTH STRIPS Supply and Laying / clamping of below listed GI/Copper earth tapes. 50 x 6mm GI Earth flat 25 x 3mm copper Earth flat 25 x 6mm GI Earth flat Supply and Installation of 8 Swg GI wire of electrical grade for connecting up of earthing of pump motors/ mains/equipments (single run). TOTAL FOR ANNEXURE - 3 QTY Rate in INR Amount in INR Q R A = QxR UNIT no's 28 850.00 23,800.00 Nos 20 600.00 12,000.00 Nos 1 1,000.00 1,000.00 Nos 20 300.00 6,000.00 Nos 10 600.00 6,000.00 Nos 162 600.00 97,200.00 Nos 8 850.00 6,800.00 mtr 250 148.00 37,000.00 Mtr 420 190.00 79,800.00 Mtr 0 - - Set 0 - - Set 0 - - Set 0 - - Nos 0 - - Nos 0 - - Mtr 0 - - Mtr 0 Mtr 0 - - Mtr 0 - - Mtr 0 - - Mtr 0 - - Nos. 0 800.00 - Nos. 0 600.00 - Nos. 0 500.00 - Nos. 0 500.00 - Nos. 0 200.00 - Nos. 0 200.00 - each 40 12,000.00 480,000.00 each 10 7,450.00 74,500.00 no 1 3,000.00 3,000.00
mtr 20 800.00 16,000.00 no 0 250.00 - Nos. 40 Mtr 125 mtr 10 Mtr 950 set 0 set 4 - - mtr 0 mtr 60 - - Mtr 20 - - mtr 50 - - 843,100.00 843,100.00 Description Unit Qty 12 way TPNMCB Vertical DB with Double Door(Legrand) 24nos 6-20A SP MCBs as outgoings and 63A FP 100mA ELCB as incomer. Hume 2 Cable Trench 300 X 50 Mtrs 22.5 3 Cable Trench 200 X 50 Mtrs 40 4 Cable Trench 100 X 50 Mtrs 7.5 5 Floor Raceway 300 X 50 Mtrs 5 6 Floor Raceway 100 X 50 Mtrs 7.5 7 Cable Trench Joint patti Mtrs 48 8 8 mm MS rods for Cable trench NOS 50 9 Metal Junction box NOS 40 10 Conduct Bends NOS 150 11 Flexible Metal pipe Mtrs 60 12 10 sq mm armoured cable raw power incoming Mtrs 150 13 2.5 sq mm armoured cable for few modes Mtrs 180 14 10 Sq mm flexible wire for DB earthing Mtrs 360 15 10 mm Anchor Fastners Mtrs 100 16 16 sq mm armoured Mtrs 150 17 cable termination for 16 sqmm NOS 10 18 cable termination for 10 sqmm NOS 10 19 cable termination for 2.5 sqmm NOS 10 20 1 inch Flexible Metal pipe Mtrs 45 SR. No 1 NOS 2 GRAND TOTAL Amt(Rs.) 16,450 16,000 2,250 4,000 4,500 1,440 3,000 1,400 3,600 1,500 87,000 54,000 57,600 3,000 860 129,000 800 8,000 600 6,000 400 4,000 1,350 UR(Rs.) 28,000 56,000 300 600 400 300 800 600 30 160 30 30 460,090.00 60 35 24 25 580 Description Unit Qty Amt(Rs.) 12 way TPNMCB Vertical DB with Double Door(Legrand) 24nos 6-20A SP MCBs as outgoings and 63A FP 100mA ELCB as incomer. Hume 2 Cable Trench 300 X 50 Mtrs 22.5 16,450 3 Cable Trench 200 X 50 Mtrs 40 16,000 4 Cable Trench 100 X 50 Mtrs 7.5 2,250 5 Floor Raceway 300 X 50 Mtrs 5 4,000 6 Floor Raceway 100 X 50 Mtrs 7.5 4,500 7 Cable Trench Joint patti Mtrs 48 1,440 8 8 mm MS rods for Cable trench NOS 50 3,000 9 Metal Junction box NOS 40 1,400 10 Conduct Bends NOS 150 3,600 11 Flexible Metal pipe Mtrs 60 1,500 12 1 inch Flexible Metal pipe Mtrs 45 1,350 13 Supply and wiring with 2runs of 2.5 sq.mm copper conductor wires with Mtrs 540 148 79,920 1run of 1.5sq.mm copper earth wire 14 Supply and wiring with 2runs of 4 sq.mm copper conductor wires with Mtrs 1980 190 376,200 1run of 2.5sq.mm copper earth wire 567,610 30 SR. No UR(Rs.) 1 NOS 2 28,000 56,000 60 35 24 25 30 600 400 300 800 600