Anda di halaman 1dari 4

1

Maximum inputs for packaged blower versions are given for the standard combustion air blower without an inlet air
filter.
2
For proper performance, this pressure must be kept constant across the burner operating range.
3
See Design Guide 110 for more information about typical fuel composition and properties.
4
All weights are approximate.
All information is based on laboratory testing. Different chamber conditions will affect the data.
All inputs based upon gross calorific values and standard conditions; 1 atmosphere, 70F (21C).
Eclipse reserves the right to change the construction and/or configuration of our products at any time without being
obliged to adjust earlier supplies accordingly.
Parameter Specification
Blower Type Chamber Pressure
"w.c. (mbar)
50 Hz 60 Hz
Maximum Input, Btu/h (kW)
1
Contact factory for chamber pressures outside the
given range, or varying chamber pressure
conditions.
-5.0 (-12.4) - 2,450,000 (718)
-3.0 (-7.5) - 2,350,000 (689)
0.0 (0.0) 2,300,000 (673) 2,150,000 (630)
1.0 (2.5) 2,200,000 (644) 2,050,000 (601)
2.0 (5.0) 2,100,000 (615) 1,950,000 (571)
Minimum Input On-Ratio, Btu/h (kW)
Lower inputs may be achieved. Contact factory.
40,000 (12)
Main Gas Inlet Pressure, "w.c. (mbar)
2
Fuel pressure at ratio regulator inlet
Natural Gas 15 to 55 (38 to 137)
Propane/Butane 15 to 30 (38 to 75)
High Fire Flame Length, inches (mm)
Measured from the outlet end of the combustor
Natural Gas 50 (1270)
Propane/Butane 60 (1524)
Maximum Chamber Temperature, F (C) Alloy Tube 1500 (815)
SiC Tube 1900 (1038)
Flame Detection Flame rod or UV Scanner
Fuel
For any other mixed gas, contact Eclipse, Inc.
Natural Gas, Propane, Butane
3
Blower Motor Power, Hp 1.0
Weight, lbs (kg)
4
Alloy Tube 141 (64)
SiC Tube 146 (66)
Approvals
Eclipse RatioMatic
Burners
Model RM0200
Datasheet 110-3
8/22/2012
Version 5
2 Eclipse RatioMatic RM0200, V5, Datasheet 110-3, 8/22/2012
Performance Graphs
NOx Emission data is given for:
Ambient combustion air ~70F (21C)
Less than 700F (370C) firing chamber
Minimal process air velocity
Low fire input adjusted to 20,000 Btu/h (6 kW)
ppm volume, dry @ 3% O
2
Neutral chamber pressure
Emissions from the burner are influenced by:
Chamber conditions
Fuel type
Firing rate
Ratio regulator adjustment
Combustion air temperature
CO emission is largely influenced by chamber conditions.
Contact your local Eclipse representative for an estimate
of CO emission on your application.
100 200 300 400 500 600 700
0
1
10
100
1000
0
400 800 1200 1600 2000 2400
Control Zone
%

E
x
c
e
s
s

A
i
r
Typical Ratio
Control
Input and excess air at low
fire changes with
ratio regulator adjustment.
Input (x 1000 Btu/h)
Input (kW)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
F
u
e
l

O
r
i
f
i
c
e

D
P

(
"
w
.
c
.
)


5
%
Input (x 1000 Btu/h)
Fuel Orifice P vs. Input
P Measured Between Taps B and D
Natural Gas (29mm orifice)
/Propane (22.5mm orifice)
Butane (19mm orifice)
2000 1500 1000 500 0 2500
Input (kW)
F
u
e
l

O
r
i
f
i
c
e

D
P

(
m
b
a
r
)


5
%
0
10
2
4
6
8
600 300 100 0 200 500 400 700
40
50
60
70
80
90
100
100 200 300 400 500 600 700
0
0
400 800 1200 1600 2000 2400
NO
X
Emission (On ratio)
Propane/Butane
Natural Gas
N
O
X

p
p
m

@

3
%

O
2
Input (x 1000 Btu/h)
Input (kW)
Air P vs. Input
(Measured between Tap C &
the Chamber with the Burner Firing)
A
i
r

P

(
m
b
a
r
)


5
%
A
i
r

P

(

w
.
c
.
)


5
%
Input (x 1000 Btu/h)
Input (kW)
0
2
4
5
7
9
10
1
3
6
8
15
0
6
12
18
22.5
3
9
250 0 750 500 1000 1500 1250 1750 225 2000
0 150 300 450 600
3 Eclipse RatioMatic RM0200, V5, Datasheet 110-3, 8/22/2012
Dimensions & Specifications
Dimensions in mm (in)
Blower Size A B C
50 Hz 670 (26.4) 492 (19.4) 362 (14.3)
60 Hz 575 (22.6) 431 (17.0) 353 (13.9)
Combustor Type D
Straight Stainless Steel Alloy Tube 330 (13)
Straight Stainless Steel Alloy Tube 406 (16)
Fuel Inlet
1-1/2 NPT/
Rc 1.5
502
(19.8)
190 B.C.
(7.5)
4X 12
(0.5)
Air Inlet
3 NPT/
Rc 3
137.5
(5.4)
102.7
(4.0)
147.5
(5.8)
319.6
(12.6)
206.1
(8.1)
19.7
(0.8)
Shown with Silicon Carbide
Combustor
Datasheet 110-3, 8/22/2012
Combustor Options
Alloy Combustor Silicon Combustor
Burner Configuration
F
E
141
(5.6)
4X 12 (0.5)
190 (7.5)
bolt circle
220 (8.7) OD
n
o
z
z
l
e
320
(12.6)
148 (5.8) OD
4X 12 (0.5)
190 (7.5)
bolt circle
220 (8.7) OD
E F
152 (6.0) 330 (13.0)