Cables
About us
Marine Cables
Prysmian in Finland
Prysmian Cables and Systems Oy has roots going back to
1912, when The Finnish Braiding Factory, the rst cable
factory in Finland, was founded in Helsinki.
The company has since had many names, The Finnish Cable
Factory, Nokia Cables, NK Cables and Pirelli Cables and
Systems Oy. Since October 2005 it is Prysmian Cables and
Systems Oy.
Production is situated in Kirkkonummi at the Pikkala cable
factory, less than 40 km west of Helsinki along the coast.
Production consists of marine cables, heating cables and low,
medium and high voltage cables. The main customer groups
are ship yards, installers, wholesalers, contractors, industry
and power utilities.
4.
5.
7.
6.
1.
Katrine Dawson
2.
Martin Pekuri
+358 10 77 55 605
3.
Katja Sepp
+358 10 77 55 808
9.
10.
+358 10 77 55 606
4.
Torbjrn Theman
+358 10 77 55 608
5.
Matti Elovirta
+358 10 77 55 876
6.
Satu Vuorio
+358 10 77 55 604
7.
Vesa Riitaoja
+358 10 77 55 472
8.
Seija Kurtn
+358 10 77 55 842
9.
Camilla Sandstrm
+358 10 77 55 219
Mikael Rautelin
+358 10 77 55 664
10.
8.
3.
2.
1.
E-mail: rstname.surname@prysmian.com
Fax: +358 9 298 2204
PRYSMIAN has built in a multi-step quality assurance programme, covering the production process from cable
design and raw material purchase to nal inspection and testing documentation.
The quality system of PRYSMIAN has been assessed and approved and is audited regularly to the ISO 9001 and
the ISO 14001 Quality System Standard by different (depending on the factory) quality assurance entities.
2
CONTENTS
General
10
LJT-HF 60 V
Screened Instrumentation and Telecommunication Cable
12
14
16
18
20
22
24
26
28
Current rating
29
Identication colours
29
Electrical data
30
Voltage drop
31
GENERAL
Marine Cables
(ship wiring cables, ship board cables)
Marine cables are for installations on board ships. They have been
type approved by a classication society and they have
a construction that follows standards for marine cables.
Conductor
Marine cable conductors are of stranded annealed copper combining
the exibility and small dimensions to provide excellent installability
and economical solutions. To minimise the cable diameter and weight
we use sector shaped conductors for bigger cross-section.
Insulation Material
XLPE (cross-linked polyethylene) is used as the main insulation
material. It withstands higher temperatures than ordinary
thermoplastic polyethylene. It is resistant against deformation
and various chemicals. It has excellent mechanical and electrical
properties. The maximum conductor temperature stipulated by
IEC 60092-351 marine cable standard is 90 C.
Sheathing Material
The sheath (jacket) is composed of halogen free, ame retardant
thermoplastic compound. It fulls the criterion
of SHF1 according to IEC 60092-359. In case of re the sheathing
material offers advantages such as reduced
emission of smoke and corrosive toxic gasses.
Quality Control
Each manufactured cable goes through a test procedure according to
the IEC 60092-300 series standards.
Marine Cables
Approvals
All above mentioned test are part of the IEC test procedures for
marine cables. As a conrmation of the successfully passed test
our products have type approval certicates from the following
classication societies:
ABS
BV
DNV
GL
LRS
RINA
RMRS
300 25
Cable sample
IEC 60332-1
50
1200 25
475
600 25550 25
50
Figure 1.
Smoke Outlet
(300 30) x (1000 100)
150
Metal Wire Ties
4000 100
Centre Line of Burner
Air Inlet
(800 20) x (400 10)
600 5
500 5
400 5
Floor
2000 100
Rig raised above ground level
Maximum Width
Figure 2.
IEC 60331-21
Clamp
Cable Sample
Support Arm
70 10
45
Figure 3.
Temperature 750 C
Flow Rates (1 bar, 20 C):
Air 80 5 Propane 5 0,25
5
Power and
Control Cables
LM-HF
0,6/1(1,2) kV
Marine Cables
(TEMA)
Unarmoured
Power and Control
Cable
Design
>
>
>
>
Standards
>
>
>
>
>
>
>
>
Conductor
Annealed stranded plain copper
- round 1,5 to 16 mm2
- round compacted 25 to 300 mm2
- sector shaped in 3-4 cores 25 to 300 mm2
Insulation
Extruded XLPE
- See page 29 for core identication colours
Sheath
Extruded black halogen free polyolene, SHF1
Installation information and electrical data on pages 28-31
Construction
IEC 60092-353 and IEC 60092-350
Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1
Halogen Free Properties
IEC 60754-1 and -2
Low Smoke Emission
IEC 61034-1 and -2
Tests
IEC 60092-353
Choice and Installation
IEC 60092-352
Maximum conductor temperature +90 C
Size *)
(n x mm2)
Conductor
Diameter/Height
approx.
(mm)
Width
approx.
(mm)
Insulation
Thickness
nominal
(mm)
Cable
Diameter
approx.
(mm)
Weight
approx.
(kg/km)
Bending
Radius
min.
(mm)
POWER CABLES
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2x1,5
2x2,5
2x4
3x1
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
5x1,5
5x2,5
5x4
5x6
5x10
5x16
5x25
5,0
5,8
6,8
7,9
9,6
11,3
12,7
14,1
15,7
18,1
20,2
1,6
2,0
2,6
1,3
1,6
2,0
2,6
3,1
4,0
5,0
4,8
5,6
6,5
7,9
9,3
10,5
11,6
1,6
2,0
2,6
3,1
4,0
5,0
5,8
6,2
7,2
8,6
10,2
11,5
1,6
2,0
2,6
3,1
4,0
5,0
5,8
7,8
9,2
10,7
12,8
15,1
17,0
18,9
8,6
9,9
12,0
14,1
15,8
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
1,6
1,7
1,8
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
0,7
0,7
0,7
0,7
0,7
0,7
0,9
8,8
10,2
11,2
12,7
14,8
16,5
18,3
20,4
22,4
25,2
28,3
8,4
9,5
10,4
8,5
8,9
10,1
11,1
12,4
14,4
16,8
17,8
19,9
22,9
26,4
29,8
33,2
36,7
9,9
11,0
12,3
13,6
16,0
18,6
21,7
22,6
26,1
30,0
33,9
37,5
10,8
12,0
13,4
15,0
17,5
20,5
24,1
200
290
385
510
720
970
1210
1490
1840
2390
2990
80
110
150
97
100
140
210
280
420
620
860
1150
1540
2150
2910
3660
4500
130
175
265
350
540
800
1180
1510
2020
2830
3860
4820
155
215
325
435
660
980
1460
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
12,7
15,3
18,1
21,8
24,5
14,2
17,2
20,3
24,8
27,9
215
325
480
670
890
305
460
690
980
1300
40
45
45
55
60
70
75
85
90
155
170
35
40
45
35
40
45
45
50
60
70
145
160
185
215
240
270
295
40
45
50
55
65
75
90
185
210
245
275
305
45
50
55
65
75
85
100
CONTROL CABLES
7x1,5
12x1,5
19x1,5
27x1,5
37x1,5
7x2,5
12x2,5
19x2,5
27x2,5
37x2,5
1,6
1,6
1,6
1,6
1,6
2,0
2,0
2,0
2,0
2,0
*) Cables are available also as (nG mm2) versions with green/yellow earth core.
55
65
75
90
100
60
70
85
150
170
Power and
Control Cables
LSM-HF
0,6/1(1,2) kV
(TEMA)
Design
Marine Cables
Armoured Power
and Control Cable
>
>
>
>
>
Standards
>
>
>
>
>
>
>
>
Conductor
Annealed stranded plain copper
- round 1,5 to 16 mm2
- round compacted 25 to 300 mm2
- sector shaped in 3-4 cores 25 to 300 mm2
Insulation
Extruded XLPE
- See page 29 for core identication colourss
Armour
Braid of copper wires designed to act as collective screen
Sheath
Extruded black halogen free polyolene, SHF1
Installation information and electrical data on pages 28-31
Construction
IEC 60092-353 and IEC 60092-350
Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath
Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1
Halogen Free Properties
IEC 60754-1 and -2
Low Smoke Emission
IEC 61034-1 and -2
Tests
IEC 60092-353
Choice and Installation
IEC 60092-352
Maximum conductor temperature +90 C
Size *)
(n x mm2)
Conductor
Diameter/Height
approx.
(mm)
Width
approx.
(mm)
Insulation
Thickness
nominal
(mm)
Diameter
over Braid
approx.
(mm)
Diameter
approx.
(mm)
Cable
7,8
9,2
10,7
12,8
15,1
17,0
18,9
8,6
9,9
12,0
14,1
15,8
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
1,6
1,7
1,8
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
0,7
0,7
0,7
0,7
0,7
0,7
0,9
8,1
9,4
10,3
12,0
14,0
15,7
17,5
19,4
21,4
24,0
26,3
7,7
8,6
9,7
7,8
8,1
9,0
10,3
11,4
13,8
16,1
16,6
18,5
21,0
24,3
27,8
31,2
34,5
8,8
10,0
11,3
13,0
15,4
17,9
20,6
21,0
24,1
28,0
31,9
35,3
9,8
10,9
12,9
14,2
17,0
19,8
23,0
10,7
12,2
13,1
15,0
17,2
18,9
21,0
23,0
25,0
27,8
30,4
10,1
10,9
12,2
10,0
10,5
11,4
12,9
13,9
16,5
19,0
20,1
22,2
25,1
28,6
32,4
36,1
39,7
11,2
12,5
13,8
15,7
18,4
21,1
23,9
24,8
28,4
32,5
36,9
40,5
12,3
13,5
15,7
17,0
20,0
22,9
26,5
270
375
470
640
870
1130
1400
1690
2070
2630
3240
135
165
225
135
160
200
275
335
530
740
1020
1340
1760
2400
3200
4080
4930
190
250
325
465
670
940
1330
1730
2270
3120
4280
5290
225
290
435
550
800
1140
1630
65
75
80
95
105
115
130
140
155
170
185
65
70
75
65
65
70
80
85
100
115
165
180
205
230
260
290
320
70
80
85
95
115
130
145
200
230
265
300
325
75
85
95
105
125
140
160
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
12,0
14,7
17,2
20,8
23,3
13,5
16,5
19,5
23,5
26,4
14,8
17,6
20,3
24,1
26,8
16,2
19,5
22,6
27,1
30,2
330
455
630
850
1100
435
600
870
1180
1540
90
110
125
145
165
100
120
140
165
185
Weight
approx.
(kg/km)
Bending
Radius
min.
(mm)
POWER CABLES
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2x1,5
2x2,5
2x4
3x1
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
5x1,5
5x2,5
5x4
5x6
5x10
5x16
5x25
5,0
5,8
6,8
7,9
9,6
11,3
12,7
14,1
15,7
18,1
20,2
1,6
2,0
2,6
1,3
1,6
2,0
2,6
3,1
4,0
5,0
4,8
5,6
6,5
7,9
9,3
10,5
11,6
1,6
2,0
2,6
3,1
4,0
5,0
5,8
6,2
7,2
8,6
10,2
11,5
1,6
2,0
2,6
3,1
4,0
5,0
5,8
CONTROL CABLES
7x1,5
12x1,5
19x1,5
27x1,5
37x1,5
7x2,5
12x2,5
19x2,5
27x2,5
37x2,5
1,6
1,6
1,6
1,6
1,6
2,0
2,0
2,0
2,0
2,0
*) Cables are available also as (nG mm2) versions with green/yellow earth core.
Instrumentation
Cables
LJST-HF
150/250 (300) V
(TEMA-TA)
Marine Cables
Armoured
Instrumentation
and
Telecommunication
Cable
Design
>
>
>
Standards
>
>
>
>
>
10
Conductor
Stranded annealed plain copper conductor 0,75 mm2
Insulation
Extruded XLPE
- See page 29 for core identication colours
Armour (common screen)
Combined electrical and mechanical protection
Braid of copper wires
- Drain conductor
Sheath
Extruded black halogen free polyolene, SHF1
Construction
IEC 60092-376 and IEC 60092-350
Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1
Halogen Free Properties
IEC 60754-1 and -2
Low Smoke Emission
IEC 61034-1 and -2
>
Tests
>
>
IEC 60092-376
Maximum conductor temperature +90 C
Also available LJST-HF 60 V, n x 2 x 0,5 mm2
Size
(n x 2 x 0,75 mm2)
1x2x0,75
2x2x0,75 (quad)
4x2x0,75
7x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
37x2x0,75
Conductor
Diameter
approx.
(mm)
Core
Diameter
approx.
(mm)
Screen
Diameter
approx.
(mm)
Diameter
approx.
(mm)
Cable
Weight
approx.
(kg/km)
Bending
Radius
min.
(mm)
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,1
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
6,2
7,2
11,5
13,0
15,5
17,0
18,0
21,0
23,5
29,0
8,5
9,5
14,0
16,0
19,0
20,5
21,5
24,5
27,5
33,0
95
130
220
320
450
520
590
740
920
1300
50
55
85
95
115
125
130
150
165
200
n x 2 x A mm
Conductor
resistance at
20 C max /km
Insulation
resistance
min M x km
Variable
Working capacitance
n x 2 x 0,75
26,0
1200
Loop inductance
Value
single pair
60 nF/km
multi pair
50 nF/km
0, 7 mH/km
11
Instrumentation
Cables
LJT-HF
60 V
(TEMA-TO)
Design
Marine Cables
Screened
Instrumentation
and
Telecommunication
Cable
>
>
>
>
Standards
>
>
>
>
>
>
>
12
Conductor
Stranded annealed plain copper conductor 0,5 mm2
Insulation
Extruded XLPE
- See page 29 for core identication colours
Common screen
Plastic coated aluminium tape
- Tinned copper drain wire
- Coverage 100 %
Sheath
Extruded black halogen free polyolene, SHF1
Construction
IEC 60092-375, -376 and IEC 60092-3
Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1
Halogen Free Properties
IEC 60754-1 and -2
Low Smoke Emission
IEC 61034-1 and -2
Tests
IEC 60092-375
Maximum conductor temperature +90 C
Size
(n x 2 x 0,5 mm2)
Conductor
Diameter
approx.
(mm)
Core
Diameter
approx.
(mm)
Screen
Diameter
approx.
(mm)
Diameter
approx.
(mm)
Weight
approx.
(kg/km)
Bending
Radius
min.
(mm)
0,9
0,9
0,9
0,9
0,9
0,9
0,9
0,9
0,9
0,9
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
2,1
4,6
5,5
9,0
10,5
13,0
14,0
15,0
17,0
19,5
24,0
6,6
7,5
11,5
13,5
16,0
17,0
18,5
21,0
23,0
27,0
50
70
125
180
250
300
340
430
530
770
55
60
90
110
130
135
150
170
185
215
1x2x0,5
2x2x0,5 (quad)
4x2x0,5
7x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
19x2x0,5
24x2x0,5
37x2x0,5
Cable
n x 2 x A mm2
Conductor
resistance at
20 C max /km
Insulation
resistance
min M x km
n x 2 x 0,5
40,4
1200
Value
single pair
multi pair
60 nF/km
50 nF/km
0,7 mH/km
13
Instrumentation
Cables
HFX-ISOSA/Cu
60 and 250 V
(TEMA-TIOA)
Design
Marine Cables
Individually
Screened
Instrumentation
and
Telecommunication
Cable
>
>
>
>
>
Standards
>
>
>
>
>
>
>
14
Conductor
Stranded annealed plain copper conductor
Insulation
Extruded XLPE
- Number identication of black and blue cores
Sreen
Individual and collective screen of plastic laminated aluminium tape
- tinned copper drain wires
Armour
Braid of plain copper wires
Sheath
Extruded orange halogen free polyolene, SHF1
Construction
IEC 60092-375, -376 and 92-3
Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1
Halogen Free Properties
IEC 60754-1 and -2
Low Smoke Emission
IEC 61034-1 and -2
Tests
IEC 60092-375, -376
Maximum conductor temperature +90 C
Size
(n x 2 x n mm )
Conductor
Resistance
Diameter
max.
approx.
(/km)
(mm)
Insulation
Thickness
nominal
(mm)
Core
Diameter
approx.
(mm)
Diameter
max.
(mm)
Cable
Weight
approx.
(kg/km)
Bending
Radius
min.
(mm)
60 V
2 x 2 x 0,5
4 x 2 x 0,5
7 x 2 x 0,5
10 x 2 x 0,5
14 x 2 x 0,5
19 x 2 x 0,5
24 x 2 x 0,5
30 x 2 x 0,5
250 V
2 x 2 x 0,75
4 x 2 x 0,75
7 x 2 x 0,75
10 x 2 x 0,75
14 x 2 x 0,75
19 x 2 x 0,75
24 x 2 x 0,75
40,4
40,4
40,4
40,4
40,4
40,4
40,4
40,4
0,9
0,9
0,9
0,9
0,9
0,9
0,9
0,9
0,4
0,4
0,4
0,4
0,4
0,4
0,4
0,4
1,9
1,9
1,9
1,9
1,9
1,9
1,9
1,9
12,2
14,4
17,2
21,1
22,9
25,4
28,7
30,5
165
220
355
475
600
760
930
1100
98
115
138
169
183
203
230
244
26,0
26,0
26,0
26,0
26,0
26,0
26,0
1,1
1,1
1,1
1,1
1,1
1,1
1,1
0,5
0,5
0,5
0,5
0,5
0,5
0,5
2,2
2,2
2,2
2,2
2,2
2,2
2,2
13,6
17,0
20,1
24,9
27,1
30,1
34,1
170
300
420
630
760
1000
1190
109
136
161
199
217
241
273
30 x 2 x 0,75
26,0
1,1
0,5
2,2
36,2
1460
290
15
Instrumentation
Cables
Marine Cables
PROFIBUS
M-02Y(ST)CHX
Bus-Cable
100V
(TEMA-PROFIBUS)
Design
>
>
>
>
>
>
Standards
>
>
>
>
>
>
>
16
Conductor
Bare copper, round stranded R-Cu 58 according to
DIN 40500 Part 4, 0,35 mm
Insulation
Polyethylene foam (cellular HDPE)
Multilayered shield
Laminated aluminium foil, overlapped
Braided screen of tinned copper wires
Inner Sheath
Halogen-free polymer HM4 acc. to DIN VDE 0207 Part 24
Outer Sheath
SHF1 compound according to IEC 60092-359
Identication
Number of cores:
- a core red
- b core green
- 2 dummy cores
Ozone
DIN VDE 0472 Part 805, Test B
Fire retardance
DIN VDE 0472 Part 805, Test C (based on IEC 60332-3)
Corrosivity of combustion gasses
DIN VDE 0472 Part 813 (corresponds to IEC 60754-2)
Smoke density
DIN VDE 0472 Part 816 (corresponds to IEC 61034)
Resistance to chemicals:
- diesel fuel to din 51601
- ASTM oil number 2 to DIN 53521
- Nato code oils 0-278, BW-TL 9150-0031/2 to VG 95214 Part 4
- Hydraulic uids, NATO code H-515,
BW-TL 9150-0031/2 to VG 95214 Part 4
- Solvent cleaning agents, Bw-TL 6850-0017 to 95214 Part4
- DE-ionozed water to VG 95214 Part4
- DE-ionized water with 3,5 % NaCl
Test to VG 95218 Part 2
Maximum conductor temperature +80 C
Transmission characteristics
>
>
>
>
>
>
>
Other properties
>
>
>
>
Voltage
100 V
Conductor resisitance 1 km loop at 20 C
max. 110 /km
Characteristic impedance
at 3 to 20 MHz
150 15
at 38,4 kHz
185 18,5
at 9,6 kHz
250 25
Wave attenuation
at 16 MHz
max. 45 dB/km
at 4 MHz
max. 22 dB/km
at 38,4 kHz
max. 5 dB/km
at 9,6 kHz
max. 3 dB/km
Mutual capacitance at 800 Hz
max. 30 nF/km
Insulation resistance at 20 C
min. 1600 Mkm
Outer sheath surface resistance min 109
Ambient temperatures
During operations as bus cable xed intallation 40 to 80 C
During installation
10 to 50 C
Conductor temperature in operation
max. 80 C
Tensile load during installation
max. 100 N
Bending radius
(D = overall diameter )
Single bending
min 10 x D
Flexing
min 20 x D
Weight
appr. 109 kg/1000 m
17
Fire Resistant
Cables
LM-FRHF
0.6/1 (1,2) kV
(TEMA-FR)
Design
Marine Cables
Unarmoured Fire
Resistant Power and
Control Cable
>
>
>
>
Standards
>
>
>
>
>
>
>
>
>
18
Conductor
Annealed stranded plain copper
- round 1,5 to 16 mm2
- round compacted 25 to 300 mm2
- sector shaped in 3-4 cores 25 to 300 mm2
Insulation
Mica tape with overlap as re resistant layer
Extruded XLPE
- see page 29 for core identication colours
Sheath
Extruded orange halogen free polyolene, SHF1
Installation information and electrical data on pages 28-31
Construction
IEC 60092-353 and IEC 60092-350
Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
Fire Resistance
IEC 60331-21
Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1
Halogen Free Properties
IEC 60754-1 and -2
Low Smoke Emission
IEC 61034-1 and -2
Tests
IEC 60092-353
Choice and Installation
IEC 60092-352
Maximum conductor temperature +90 C
Size *)
(n x mm2)
Conductor
Diameter/Height
Width
approx.
approx.
(mm)
(mm)
Insulation
Thickness
nominal
(mm)
Diameter
approx.
(mm)
Cable
Weight
approx.
(kg/km)
Bending
Radius
min.
(mm)
POWER CABLES
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2x1,5
2x2,5
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
5,0
5,8
6,8
7,9
9,6
11,3
12,7
14,1
15,7
18,1
20,2
1,6
2,0
1,6
2,0
2,6
3,1
4,0
5,0
5,8
5,6
6,5
7,9
9,3
10,5
11,6
1,6
2,0
2,6
3,1
4,0
5,0
5,8
6,2
7,2
8,6
10,2
11,5
9,2
10,7
12,8
15,1
17,0
18,9
8,6
9,9
12,0
14,1
15,8
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
1,6
1,7
1,8
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
10,3
11,8
12,8
13,9
16,0
17,7
19,6
21,6
23,8
26,6
28,9
10,0
11,0
10,4
11,5
12,6
13,8
15,9
18,1
21,0
21,7
24,3
27,8
31,4
34,5
38,3
11,4
12,4
13,8
15,0
17,4
20,1
27,2
24,7
27,7
31,9
35,7
39,5
215
310
410
530
740
990
1240
1520
1890
2450
3020
95
125
120
160
235
300
450
650
980
1230
1600
2230
3010
3750
4620
145
195
290
375
570
800
1640
1620
2100
2940
3970
4960
45
50
55
60
65
75
80
90
100
160
175
45
45
45
50
55
60
65
75
170
175
195
225
255
280
310
50
50
60
65
70
85
95
200
225
260
290
320
1,6
1,6
1,6
1,6
1,6
1,6
2,0
2,0
2,0
2,0
2,0
2,0
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
12,0
14,5
17,7
20,8
25,1
28,1
13,5
16,1
19,8
23,2
28,0
31,5
175
250
370
550
770
1010
245
340
520
770
1090
1440
50
60
75
85
155
170
55
65
80
95
170
190
CONTROL CABLES
5x1,5
7x1,5
12x1,5
19x1,5
27x1,5
37x1,5
5x2,5
7x2,5
12x2,5
19x2,5
27x2,5
37x2,5
*) Cables are available also as (nG mm2) versions with green/yellow earth core.
19
Fire Resistant
Cables
LSM-FRHF
0.6/1 (1,2) kV
(TEMA-AFR)
Design
Marine Cables
Armoured Fire
Resistant Power and
Control Cable
>
>
>
>
>
Standards
>
>
>
>
>
>
>
>
>
20
Conductor
Annealed stranded plain copper
- round 1,5 to 16 mm2
- round compacted 25 to 300 mm2
- sector shaped in 3-4 cores 25 to 300 mm2
Insulation
Mica tape with overlap as re resistant layer
Extruded XLPE
- See page 29 for core identication colours
Armour
Braid of copper wires designed to act as collective screen
Sheath
Extruded orange halogen free polyolene, SHF1
Installation information and electrical data on pages 28-31
Construction
IEC 60092-353 and IEC 60092-350
Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
Fire Resistance
IEC 60331-21
Flame Retardance
IEC 60332-3-22= (cat A) and IEC 60332-1
Halogen Free Properties
IEC 60754-1 and -2
Low Smoke Emission
IEC 61034-1 and -2
Tests
IEC 60092-353
Choice and Installation
IEC 60092-352
Maximum conductor temperature +90 C
Size *)
(n x mm2)
Conductor
Diameter/Height
Width
approx.
approx.
(mm)
(mm)
Insulation
Thickness
nominal
(mm)
Diameter
over Braid
approx.
(mm)
Diameter
approx.
(mm)
Cable
9,2
10,7
12,8
15,1
17,0
18,9
8,6
9,9
12,0
14,1
15,8
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
1,6
1,7
1,8
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
8,9
10,3
11,2
12,7
14,6
16,3
17,9
19,8
21,8
24,4
26,7
8,4
9,5
10,4
8,9
9,9
11,1
12,9
14,9
17,1
19,5
19,8
22,2
25,4
29,2
32,0
35,4
9,8
10,9
12,9
14,1
16,4
18,9
21,9
22,6
25,4
29,1
33,2
36,6
11,4
13,0
13,9
15,6
17,7
19,4
21,2
23,3
25,3
28,1
30,6
10,8
12,0
13,0
11,2
12,5
13,6
15,6
17,8
20,0
23,0
23,7
26,3
29,8
33,9
37,0
40,8
12,4
13,4
15,7
16,9
19,3
22,0
25,3
26,7
29,8
33,9
38,2
42,0
270
380
475
640
870
1140
1400
1700
2070
2650
3250
140
180
240
170
220
280
380
560
770
1200
1420
1810
2450
3360
4120
5030
210
265
380
465
690
960
1380
1830
2340
3210
4360
5390
70
80
85
95
110
120
130
140
155
170
185
65
75
80
70
80
85
95
110
125
190
190
215
240
275
300
330
75
85
95
105
120
135
155
215
240
275
310
340
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
11,3
14,0
16,4
19,3
23,3
26,2
13,0
15,3
18,3
21,6
26,1
29,3
13,8
16,7
19,4
22,5
26,8
29,9
15,8
18,3
21,5
24,9
29,8
33,3
255
385
500
710
960
1230
375
490
670
950
1300
1680
85
105
120
140
165
180
95
110
130
150
180
200
Weight
approx.
(kg/km)
Bending
Radius
min.
(mm)
POWER CABLES
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2x1,5
2x2,5
2x4
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
5,0
5,8
6,8
7,9
9,6
11,3
12,7
14,1
15,7
18,1
20,2
1,6
2,0
2,6
1,6
2,0
2,6
3,1
4,0
5,0
5,8
5,6
6,5
7,9
9,3
10,5
11,6
1,6
2,0
2,6
3,1
4,0
5,0
5,8
6,2
7,2
8,6
10,2
11,5
CONTROL CABLES
5x1,5
7x1,5
12x1,5
19x1,5
27x1,5
37x1,5
5x2,5
7x2,5
12x2,5
19x2,5
27x2,5
37x2,5
1,6
1,6
1,6
1,6
1,6
1,6
2,0
2,0
2,0
2,0
2,0
2,0
*) Cables are available also as (nG mm2) versions with green/yellow earth
core.
21
Fire Resistant
Cables
LJST-FRHF
150/250 (300) V
(TEMA-TAFR)
Design
Marine Cables
Armoured
Fire Resistant
Instrumentation and
Telecommunication
Cable
>
>
>
>
Standards
>
>
>
>
>
>
>
>
22
Conductor
Stranded annealed plain copper conductor 0,75 mm2
Insulation
Mica tape with overlap as re resistant layer
Extruded EPR, nominal thickness 0,6 mm
- See page 29 for core identication colours
Armour (common screen)
Braid of copper wires
- drain conductor
Sheath
Extruded orange halogen free polyolene, SHF1
Construction
IEC 60092 -376
Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
Fire Resistance
IEC 60331-21
Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1
Halogen Free Properties
IEC 60754-1 and -2
Low Smoke Emission
IEC 61034-1 and -2
Tests
IEC 60092-376
Maximum conductor temperature +90 C
(n x 2 x 0,5 mm )
Conductor
Diameter
approx.
(mm)
Core
Diameter
approx.
(mm)
Screen
Diameter
approx.
(mm)
Diameter
approx.
(mm)
Weight
approx.
(kg/km)
Bending
Radius
min.
(mm)
1x2x0,75
2x2x0,75 (quad)
4x2x0,75
7x2x0,75
12x2x0,75
19x2x0,75
24x2x0,75
37x2x0,75
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,1
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,9
6,9
8,0
13,4
15,4
19,7
24,0
26,9
33,8
9,2
10,4
16,3
18,5
23,2
27,7
31,1
37,3
115
165
335
465
710
1010
1240
1780
55
60
100
110
140
165
185
225
Size
Cable
n x 2 x A mm2
Conductor
resistance at
20 C max /km
Insulation
resistance
min M x km
n x 2 x 0,75
26,0
1200
Value
single pair
multi pair
60 nF/km
50 nF/km
0,7 mH/km
23
Medium Voltage
Cables
LSESM
6/10 (12) kV
(TEMA-A)
Design
Marine Cables
Armoured Medium
Voltage Power Cable
>
>
>
>
>
>
Standards
>
>
>
>
>
>
>
>
24
Conductor
Annealed stranded and compressed copper conductor
Insulation
Extruded off-white EPR-rubber, nominal thickness 3,4 mm
Metallic Screen
Braid of copper wires
Inner Covering
Extruded halogen free EPDM compound
Armour
Braid of copper wires
Sheath
Extruded red halogen free compound, SHF1
Construction
IEC 60092-354 and IEC 60092-350
Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1
Halogen Free Properties
IEC 60754-1 and -2
Low Smoke Emission
IEC 61034-1 and -2
Tests
IEC 60092-354
Choice and Installation
IEC 60092-352
Maximum conductor temperature +90 C
Size
(n x mm2)
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
3x35
3x50
3x70
3x95
3x120
Conductor
Diameter
approx.
(mm)
Core
Diameter
approx.
(mm)
Inner Cover
Thickness
approx.
(mm)
Braid
Diameter
approx.
(mm)
Diameter
approx.
(mm)
Weight
approx.
(kg/km)
7,3
8,8
10,3
12,1
13,6
15,0
16,8
19,1
21,4
7,3
8,8
10,3
12,1
13,6
18,5
19,9
21,1
23,1
24,6
26,9
28,2
31,1
33,8
18,4
19,8
21,0
23,0
24,5
1,2
1,2
1,2
1,2
1,2
1,4
1,4
1,4
1,4
1,6
1,6
1,6
1,8
1,8
22,5
23,9
25,0
27,0
28,6
31,3
32,6
35,8
38,6
44,9
48,0
50,5
55,1
58,5
26,4
27,8
29,2
31,2
33,0
35,9
37,2
40,6
43,6
50,6
54,0
56,8
61,6
65,4
1290
1480
1740
2080
2410
2850
3250
4110
4750
4370
5040
5950
7190
8390
Size
Cross
Section
Current
rating at +45 C
ambient 1)
(n x mm2)
(mm2)
(A)
Conductor Resistance
RDC
at +20 C
1x35
35
141
1x50
50
186
1x70
70
229
1x95
95
278
1x120
120
322
1x150
150
369
1x185
185
421
1x240
240
495
1x300
300
570
3x35
35
104
3x50
50
130
3x70
70
160
3x95
95
194
3x120
120
225
1) IEC 60092-352 Table B.4 x 0,95 (see also Tables A.1 - A.8)
Size
0,529
0,391
0,270
0,195
0,154
0,126
0,100
0,0762
0,0607
0,529
0,391
0,270
0,195
0,154
Reactance
(/km)
(n x mm2)
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
3x35
3x50
3x70
3x95
3x120
Cable
at 50 Hz
X50
at 60 Hz
X60
DC
0,144
0,138
0,129
0,123
0,119
0,118
0,113
0,110
0,114
0,121
0,116
0,108
0,104
0,101
0,172
0,165
0,155
0,148
0,143
0,142
0,136
0,132
0,137
0,145
0,140
0,130
0,125
0,121
1,328
0,982
0,678
0,490
0,387
0,316
0,251
0,191
0,152
1,328
0,982
0,678
0,490
0,387
Inductance
L
Capacitance
C
(/km)
at +45 C
at +85 C
(mH/km)
( F/km)
0,581
0,429
0,297
0,214
0,169
0,138
0,110
0,084
0,067
0,581
0,429
0,297
0,214
0,169
0,664
0,491
0,339
0,245
0,193
0,158
0,126
0,096
0,076
0,664
0,491
0,339
0,245
0,193
0,457
0,438
0,411
0,392
0,379
0,375
0,360
0,350
0,343
0,385
0,370
0,345
0,331
0,320
0,280
0,320
0,360
0,400
0,440
0,480
0,530
0,580
0,630
0,280
0,320
0,360
0,400
0,440
1,070
0,823
0,604
0,467
0,392
0,342
0,292
0,247
0,224
1,046
0,801
0,582
0,447
0,372
1,270
0,984
0,728
0,569
0,481
0,423
0,364
0,311
0,286
1,237
0,953
0,699
0,541
0,454
1,099
0,852
0,631
0,493
0,417
0,366
0,315
0,270
0,248
1,071
0,825
0,605
0,469
0,393
25
Medium Voltage
Cables
LSESM
12/20 (24) kV
(TEMA-A)
Design
Marine Cables
Armoured Medium
Voltage Power Cable
>
>
>
>
>
>
Standards
>
>
>
>
>
>
>
>
26
Conductor
Annealed stranded and compressed copper conductor
Insulation
Extruded off-white EPR-rubber, nominal thickness 5,5 mm
Metallic Screen
Braid of copper wires
Inner Covering
Extruded halogen free EPDM compound
Armour
Braid of copper wires
Sheath
Extruded red halogen free compound, SHF1
Construction
IEC 60092-354 and IEC 60092-350
Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1
Halogen Free Properties
IEC 60754-1 and -2
Low Smoke Emission
IEC 61034-1 and -2
Tests
IEC 60092-354
Choice and Installation
IEC 60092-352
Maximum conductor temperature +90 C
Conductor
Diameter
approx.
(mm)
Core
Diameter
approx.
(mm)
Inner Cover
Thickness
approx.
(mm)
Braid
Diameter
approx.
(mm)
Diameter
approx.
(mm)
Weight
approx.
(kg/km)
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
3x35
3x50
3x70
3x95
7,3
8,8
10,3
12,1
13,6
15,0
16,8
19,1
7,3
8,8
10,3
12,1
23,1
24,5
25,9
27,9
29,4
31,5
32,8
35,5
23,0
24,4
25,8
27,8
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,4
1,6
1,6
1,6
27,1
28,5
29,9
32,2
34,2
36,3
37,6
40,2
55,3
58,3
61,3
65,5
31,3
32,9
34,3
36,8
39,0
41,1
42,6
45,5
61,8
65,0
68,4
72,9
1640
1860
2160
2560
3010
3430
3860
4630
5850
6690
7740
9080
Size
Cross
Section
Current
rating at +45 C
ambient 1)
(n x mm2)
(mm2)
(A)
Size
(n x mm2)
Conductor Resistance
RDC
at +20 C
1x35
35
141
1x50
50
186
1x70
70
229
1x95
95
278
1x120
120
322
1x150
150
369
1x185
185
421
1x240
240
495
3x35
35
104
3x50
50
130
3x70
70
160
3x95
95
194
1) IEC 60092-352 Table B.4 x 0,95 (see also Tables A.1 - A.8)
Size
Cable
0,529
0,391
0,270
0,195
0,154
0,126
0,100
0,0762
0,529
0,391
0,270
0,195
Reactance
(/km)
at 60 Hz
X60
DC
(n x mm2)
at 50 Hz
X50
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
3x35
3x50
3x70
3x95
0,154
0,148
0,139
0,133
0,130
0,126
0,122
0,117
0,135
0,129
0,121
0,116
0,185
0,178
0,167
0,160
0,156
0,152
0,146
0,141
0,162
0,155
0,146
0,139
1,328
0,982
0,678
0,490
0,387
0,316
0,251
0,191
1,328
0,982
0,678
0,490
Inductance
L
Capacitance
C
(/km)
at +45 C
at +85 C
(mH/km)
( F/km)
0,581
0,429
0,297
0,214
0,169
0,138
0,110
0,084
0,581
0,429
0,297
0,214
0,664
0,491
0,339
0,245
0,193
0,158
0,126
0,096
0,664
0,491
0,339
0,245
0,492
0,472
0,443
0,425
0,413
0,402
0,387
0,373
0,430
0,412
0,386
0,368
0,200
0,220
0,250
0,280
0,300
0,320
0,350
0,390
0,200
0,220
0,250
0,280
1,081
0,834
0,614
0,478
0,403
0,351
0,300
0,254
1,061
0,815
0,596
0,460
1,285
0,999
0,743
0,584
0,496
0,435
0,376
0,322
1,257
0,972
0,717
0,558
1,113
0,865
0,643
0,506
0,430
0,377
0,326
0,279
1,089
0,842
0,621
0,484
27
Technical
Information
General
The rated voltage of a cable must not be lower than the nominal voltage of the circuit in which it is used. The ambient temperature during
operation should be at least 10 C lower than the maximum conductor
temperature allowed to the insulation material.
Rated Voltage
The rated voltages of cables are expressed as Uo/U(Um) where
Uo the rated voltage between the conductor and earth,
or between the conductor and the metal screen for
which the cable is designed.
U the rated voltage between the conductors for which
the cable is designed.
Um the highest system voltage for which the cables
may be used
Marine Cables
Installation Temperature
2 3 3 2 1
or
Earthing of Braids
Earthing of braids is to be carried out in accordance with
the regulations of the classication society.
1 3
3 1
or
2 3
2 1
Bending Radius
Some other installation examples of single core
cables (phases 1, 2 and 3)
Outer covering
Unarmoured or
unbraided
Overall
diameter of
cable (D)
Minimum
internal radius
of bend
25 mm
4D
25 mm
6D
3 1
Any
6D
Any
6D
Composite
polyester/metal
laminate screened
units or collective tape
screening
Any
8D
Thermoplastic or
thermosetting
with shaped
copper
conductors
Any
Any
Medium voltage
cable
Any
Thermoplastic or
thermosetting
with circular
copper
conductors
3 1
2 3
2 1
3 2 1
or
3 1
3 1
3 1
or
8D
single core
12D
3-core
9D
2 3
2 1
3 2 1
2 3
3 2 1
3 1
3 1
3 1
3 1
3 1
Current Rating
Conductor
cross
section
Cores
Reduction
(mm2)
12
19
27
37
1,00
0,85
0,70
0,70
0,58
0,52
0,44
0,37
0,33
0,30
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
23
30
41
52
72
96
127
157
196
242
293
339
389
444
522
601
20
26
35
44
61
82
108
133
167
206
249
288
331
377
444
511
16
21
29
36
50
67
89
110
137
169
205
237
272
311
365
421
16
21
29
36
50
67
89
110
137
169
205
237
272
311
365
421
13
18
24
30
42
56
74
92
12
16
10
13
9
11
8
10
7
9
Cable
diameter
Time
constant
Critical
duration
(rest time
between
service
periods)
Service time
correction factor
Intermittent
service
correction
factor
D (mm)
T (min)
3xT (min)
30 min
60 min
4 min load
+ 6 min rest
1,058
1,058
1,058
1,059
1,059
1,061
1,081
1,126
1,186
1,255
1,328
1,403
1,479
1,554
1,705
1,852
1,996
2,136
2,273
1,058
1,058
1,058
1,058
1,058
1,058
1,059
1,066
1,081
1,105
1,137
1,173
1,212
1,254
1,341
1,432
1,522
1,613
1,702
1,083
1,127
1,170
1,208
1,242
1,273
1,376
1,433
1,468
1,490
1,506
1,518
1,527
1,534
1,544
1,551
1,556
1,559
1,562
5
6
7
8
9
10
15
20
25
30
35
40
45
50
60
70
80
90
100
35
40
45
50
55
60
65
70
75
1,10
1,05
1,00
0,94
0,88
0,82
0,74
0,67
0,58
2,2
2,8
3,4
4,1
4,8
5,5
9,5
14
19
24
30
36
42
48
62
76
91
107
123
6,5
8,3
10
12
14
16
28
42
57
73
89
107
125
145
185
228
273
320
368
Identification Colours
POWER AND CONTROL CABLE CORES
Cable with earth core
2X
Blue
3X
4X
537X
Blue
Type
Line
Brown
PE
3G
Brown
Black
Grey
4G
Brown
Black
Grey
5G
737G
Blue
Blue
Line
Brown
Brown
Black
Grey
Brown
Black
Grey
White insulation with black numbers + last core green and yellow
1
2
N
Core a
White insulation +
black number
Core b
Blue insulation +
black number
1
3
2*N-1
2
4
2*N
29
Cable Type
LM-HF, LSM-HF,
LM-FRHF, LSM-FRHF
Cross
Section
(n x mm2)
(mm2)
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
2 x 1,5
2 x 2,5
3 x 1,5
3 x 2,5
3x4
3x6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240
3 x 300
4 x 1,5
4 x 2,5
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150
4 x 185
4 x 240
4 x 300
30
30
35
50
70
95
120
150
185
240
300
1,5
2,5
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
Conductor Resistance
(IEC 60228)
R
at +20 C
0,524
0,387
0,268
0,193
0,153
0,124
0,0991
0,0754
0,0601
12,1
7,41
12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,124
0,0991
0,0754
0,0601
12,1
7,410
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,124
0,0991
0,0754
0,0601
(/km)
at +45 C
0,575
0,425
0,294
0,212
0,168
0,136
0,109
0,083
0,066
13,289
8,138
13,289
8,138
5,063
3,383
2,010
1,263
0,798
0,575
0,425
0,294
0,212
0,168
0,136
0,109
0,083
0,066
13,289
8,138
5,063
3,383
2,010
1,263
0,798
0,575
0,425
0,294
0,212
0,168
0,136
0,109
0,083
0,066
Inductance
L
at +85 C
0,658
0,486
0,336
0,242
0,192
0,156
0,124
0,095
0,075
15,191
9,303
15,191
9,303
5,788
3,867
2,297
1,444
0,913
0,658
0,486
0,336
0,242
0,192
0,156
0,124
0,095
0,075
15,191
9,303
5,788
3,867
2,297
1,444
0,913
0,658
0,486
0,336
0,242
0,192
0,156
0,124
0,095
0,075
(mH/km)
0,316
0,315
0,303
0,292
0,284
0,286
0,281
0,276
0,288
0,336
0,313
0,336
0,313
0,293
0,281
0,266
0,254
0,211
0,202
0,200
0,197
0,190
0,189
0,191
0,193
0,190
0,188
0,359
0,336
0,317
0,304
0,289
0,278
0,267
0,258
0,217
0,213
0,206
0,205
0,209
0,209
0,206
0,204
Electrical Data
Cable Type
LM-HF, LSM-HF,
LM-FRHF, LSM-FRHF
(n x mm2)
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
2 x 1,5
2 x 2,5
3 x 1,5
3 x 2,5
3x4
3x6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240
3 x 300
4 x 1,5
4 x 2,5
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150
4 x 185
4 x 240
4 x 300
Reactance
(/km)
at 50 Hz
at 60 Hz
X50
X60
0,099
0,099
0,095
0,092
0,089
0,090
0,088
0,087
0,090
0,106
0,098
0,106
0,098
0,092
0,088
0,083
0,080
0,066
0,064
0,063
0,062
0,060
0,059
0,060
0,061
0,060
0,059
0,113
0,106
0,099
0,096
0,091
0,087
0,084
0,081
0,068
0,067
0,065
0,064
0,066
0,066
0,065
0,064
0,119
0,119
0,114
0,110
0,107
0,108
0,106
0,104
0,108
0,127
0,118
0,127
0,118
0,111
0,106
0,100
0,096
0,080
0,076
0,075
0,074
0,072
0,071
0,072
0,073
0,072
0,071
0,136
0,127
0,119
0,115
0,109
0,105
0,101
0,097
0,082
0,080
0,078
0,077
0,079
0,079
0,078
0,077
DC
1,316
0,972
0,673
0,485
0,384
0,311
0,249
0,189
0,151
30,382
18,606
30,382
18,606
11,575
7,734
4,595
2,888
1,825
1,316
0,972
0,673
0,485
0,384
0,311
0,249
0,189
0,151
30,382
18,606
11,575
7,734
4,595
2,888
1,825
1,316
0,972
0,673
0,485
0,384
0,311
0,249
0,189
0,151
(mV/Am)
at 50 Hz
1-phase
3-phase
at 60 Hz
1-phase
3-phase
1,172
0,896
0,653
0,498
0,415
0,357
0,305
0,255
0,229
24,432
15,003
24,432
15,003
9,371
6,293
3,776
2,406
1,540
1,129
0,853
0,612
0,459
0,379
0,321
0,272
0,223
0,192
24,441
15,011
9,380
6,302
3,785
2,415
1,561
1,150
0,859
0,619
0,465
0,385
0,328
0,278
0,229
0,198
1,195
0,920
0,675
0,520
0,436
0,379
0,326
0,276
0,251
24,458
15,026
24,458
15,026
9,393
6,314
3,796
2,425
1,556
1,144
0,868
0,627
0,474
0,393
0,335
0,286
0,237
0,206
24,468
15,037
9,403
6,324
3,807
2,436
1,581
1,169
0,875
0,635
0,481
0,400
0,343
0,294
0,245
0,213
1,015
0,776
0,565
0,431
0,359
0,309
0,264
0,221
0,198
21,159
12,993
21,159
12,993
8,115
5,450
3,270
2,084
1,334
0,978
0,738
0,530
0,398
0,328
0,278
0,235
0,193
0,166
21,167
13,000
8,123
5,457
3,278
2,091
1,352
0,996
0,744
0,536
0,403
0,333
0,284
0,241
0,198
0,171
1,035
0,796
0,585
0,450
0,378
0,328
0,282
0,239
0,217
21,181
13,013
21,181
13,013
8,135
5,468
3,288
2,100
1,347
0,991
0,751
0,543
0,410
0,340
0,291
0,248
0,206
0,178
21,190
13,022
8,144
5,477
3,297
2,109
1,369
1,013
0,758
0,550
0,417
0,346
0,297
0,254
0,212
0,184
31
CHINA
Prysmian Tianjin Cables Co. Ltd
Room 1505-06, Tower A, City Center of
Shanghai
No. 100 ZunYi Road, Shanghai 200051
China
Tel. +86-21-6237.1699
Fax +86-21-6237.1195
FRANCE
Prysmian Energie Cables et Systmes
France s.a.
19, Avenue de la Paix - BP 712
Paron -89100, Sens Cedex, France
Tel. +33 3 8695 7769
Fax +33 3 8695 7781
GERMANY
Prysmian Kabel und Systeme GmbH
Austrasse 99
D-96465 Neustadt bei Coburg, Germany
Tel. +49 9568 93 2697
Fax +49 9568 93 2527
ITALY
Prysmian Cavi e Sistemi Energia Srl
Via Sarca 222, 20126 Milan, Italy
Tel. +39 02 64491
Fax +39 02 6449 2931
www.prysmian.
www.ship-technology.com
THE NETHERLANDS
Prysmian Cables & Systems B.V.
Schieweg 9 - P.O. Box 495
2600 AL Delft, The Netherlands
Tel. +31 15 2605 260
Fax +31 15 2605 713
NORWAY
Prysmian Kabler og Systemer AS
Anolitveien 4
NO-1400 Ski, Norway
Tel. +47 64 915 713
Fax +47 64 915 714
RUSSIA
Prysmian Cables and Systems
20/12, Str. 1, Podsosenskiy Per.
Moscow 105062, Russia
Tel. +7 095 933 7036
Fax +7 095 933 7035
SOUTH AMERICA
Prysmian Energia Cabos e Sistemas do
Brasil S.A.
Av. Alexandre de Gusmao 145
09110-900 Santo Andr- SP, Brazil
Tel. +55 11 49984000
Fax + 55 11 49984811
SPAIN
Prysmian Cables y Sistemas S.L.
Carretera C-15 Km 2 - Poligon Industrial
den Notari
08800 Vilanova i la Geltr (Barcelona),
Spain
Tel. +34 93 811 61 74
Fax +34 93 811 61 75
SWEDEN
Prysmian Kablar och System AB
Turebergs All 2
S-191 62 Sollentuna, Sweden
Tel. +46 8 260 416
Fax +46 8 260 413
USA
Prysmian Cables & Systems North America
700 Industrial Drive
Lexington, SC 29072, USA
Tel. +1 803 9511130
Fax +1 803 9511092
HEAD OFFICE
Prysmian Cables and Systems - Viale Sarca 222, 20126 Milano, Italy - tel. +39 02 6449 1, fax +39 02 6449 2931 - www.prysmian.com