Anda di halaman 1dari 40

www.centrumklima.

pl
AIR CONDITIONERS
Air Conditioners Catalogue
Your climate solution center
Centrum Klima S.A.
C
DC
AUTO
Turbo
ENERGY CLASS
The energy class is a measure of energy e ciency of a
given piece of equipment, indicating whether the work
performed by the machine is adequate to power con-
sumption, and whether energy loss is not excessive.
TURBO
This function helps reach the required temperature
within the shortest time possible.
Legend
HEATING
Heating is carried out by heat pump. The indoor unit
delivers heat absorbed by the outdoor unit from ambi-
ent air.
COOLING
The basic function of every A/C unit. The indoor unit re-
moves heat from the room and transfer is to the outdoor
unit for dissipation by means of the refrigerant.
FAN
An operating mode where the indoor unit works solely
as fan, i.e. without the outdoor unit. Only the indoor
unit fan works.
AUTO
AUTO an operating mode in which the unit maintains
a pre-set temperature, using the Heating or Cooling
functions.
R407C
Refrigerant used in older A/C systems. Considered
unsafe for the ozone layer.
R410A
Modern refrigerant used in A/C systems. Due to its
properties, A/C systems can operate at higher pressure
levels than in case of R407C, and are more e cient.
DC INVERTER
Direct current inverter compressors are more energy
efficient than traditional alternating current compres-
sors (AC INVERTER). DC INVERTER units equipped with
modern microprocessors are capable of quickly and
efficiently reaching a pre-set room temperature. They
represent a new development in the AC technology.
AUTORESTART
AUTORESTART a function enabling recovery to pre-
set operating mode and temperatures after temporary
or prolonged power failure. The unit remembers its
operating parameters and returns to them when power
supply is returned.
REMOTE CONTROL
Remote control enables control of the system from a
distance away from the indoor unit. The remote has a
display showing current operating mode, temperature
and other operating parameters.
SLEEP
With this function, it is possible to use the system at
night, when noise level from the indoor unit is impor-
tant. The indoor units fan operates at lowest speed
possible.
SWING
Function enabling even distribution of cold or hot air
stream through movable louvers. Inside air is heated
or cooled evenly.
TIMER
Automatic start or stop of the unit after lapse of a certain
period of time. Set from the remote control.
PUMP
The pump automatically removes condensate.
An additional condensate pump is not required.
CONDENSATE TANK
Condensate is collected in a special tank. The tank
is protected from over-filling to prevent flooding
of the unit.
MULTI
A system combining one outdoor unit with several (up
to 4) indoor units. The indoor units can be of any type
(wall-mounted, ceiling-mounted or duct-type).
HOT AIR REMOVAL (HAR)
Hot air is removed by means of installation set compris-
ing exible duct and special ttings.
DUALSPLIT
A system combining one outdoor unit two indoor
units.
1
Air conditioner catalog
MISTRAL Brand
GALANZ Brand
Operating principle DC Inverter
R410A DC INVERTER (MULTI)
Indoor wall-mounted units
Indoor duct units
Indoor cassette units
Outdoor units
R410A DC INVERTER
Duct air conditioners
Cassette air conditioners
Wall-mounted air conditioners
R410A
Wall-mounted air conditioners
Duct air conditioners
Cassette air conditioners
Ceiling - oor air conditioners
Floor air conditioners
R407C
Portable air conditioners
Assembly accessories
Products for cleaning
Contents
2
4
6
9
10
11
12
14
15
16
17
20
21
22
23
24
25
33
02/10
More information on www.klimatyzatorymistral.pl
Centrum Klima S.A.
2
Your satisfaction about the purchase is our main goal. This is exactly the reason why
Centrum Klima is renowned in Poland and abroad. We only oer products meeting
the most stringent demands of our clients in respect of quality to price ratio. This
is true for our own and imported porducts, including MISTRAL equipment.
MISTRAL Products, meeting all quality requirements, are manufactured in China
by one of the largest AC corporations. The heart of the MISTRAL AC unit is Japanese
compressor ensuring outstanding reliability. The MISTRAL brand stands for great
performance conrmed by numerous certicates, functionality, and attractive
design.
The MISTRAL range of porducts includes:
wall-mounted units (DC INVERTER)
ceiling-mounted units (DC INVERTER)
duct units (DC INVERTER)
3
Air conditioner catalog
Perfect blend of modern technology
and functional design
Centrum Klima S.A.
4
The secret of comfort is in the quality
5
Air conditioner catalog
Centrum Klima S.A. has been successfully marketing the GALANZ range of prod-
ucts for a few years. Our customers rightly appreciate GALANZ products for their
high quality and attractive design. GALANZ is a leading Chinese manufacturer of
AC equipment, and the second largest manufacturer of electronic equipment in
China.
Product range oered by Centrum Klima S.A. has been extended with the addition
of new, advanced units, using the R410A coolant. Using newest solutions which
help improve e ciency, the new units have excellent energy e ciency specica-
tions, conrmed by their very high energy class.
Galanz oers split:
wall-mounted,
high pressure duct units,
AC cabinets.
Centrum Klima S.A. also oers portable units.
Centrum Klima S.A.
6
Operating principle DC Inverter
Technical solutions used in AC equipment with DC inverter compressors are
among the most modern. Microprocessor control and state of the art power-
supply system make DC INVERTER equipment 40% more e cient. DC INVERTER
equipment meets requirements of the EU directive on energy certication of
buildings.
Modern technology used in the DC INVERTER compressor enable adjustment
of operating capacity. Traditional compressors operate at full power when the
unit is in the Cooling or Heating mode, and are switched o when the required
temperature is reached. This means an increased power consumption, higher
noise level and shorter operating life of the unit.
The indoor unit working with a DC INVERTER compressor can maintain tem-
perature more e ciently, gaining the required temperature more quickly. Units
with DC INVERTER compressors can maintain temperature more accurately
than traditional systems, maintaining 0,5C accuracy.
Traditional compressors start up at full rev. speed, while DC inverter compres-
sors accelerate smoothly, reducing consumption of electricity.
Adjustable output of DC INVERTER compressors helps reduce noise.
inverter standard type temperature setting
compressor speed
1800rpm
start
3000rpm
7000rpm
time
low noise
low turnaer
high temperature
uctuations
small temperature
uctuations
compressor speed temperature uctuations
long time temperature settings
short-term temperature settings
COMPRESSOR EFFICIENCY
TEMPERATURE
INRUSH CURRENT
NOISE
7
Air conditioner catalog
Operating principle MULTI DC Inverter
Outdoor
units
Indoor
units
Table selection of indoor units
The MULTI DC INVERTER system is an AC system comprising of to
four independent indoor units and one outdoor unit. It is impor-
tant that the indoor units can be of dierent types. Therefore, a
MULTI DC INVERTER system can comprise 2 wall-mounted units,
1 duct unit and 1 ceiling-mounted unit. Indoor units with dierent
cooling capacity can be combined into systems.
The permitted congurations of indoor units are presented in the
table below.
The indoor units can work independently which means excellent
exibility and operating independence to the user.
MULTI DC INVERTER 1 X 2
M2OC-18HRDN1
1-indoor
unit [kW]
2-indoor units
[kW]
2,1 2,1+2,1 2,6+2,6
2,6 2,1+2,6 2,6+3,5
3,5 2,1+3,5 3,5+3,5
5,3 2,1+5,3
Nominal cooling
performance 5,30 [kW]
Indoor unit 5,3kW can not be a cassette or duct unit
MULTI DC INVERTER 1 X 3
M3OC-21HRDN1
1-indoor
unit [kW]
2-indoor units
kW]
3-indoor units
[kW]
2,1 2,1+2,1 2,6+2,6 2,1+2,1+2,1 2,1+2,6+3,5
2,6 2,1+2,6 2,6+3,5 2,1+2,1+2,6 2,6+2,6+2,6
3,5 2,1+3,5 2,6+5,3 2,1+2,1+3,5 2,6+2,6+3,5
5,3 2,1+5,3 3,5+3,5 2,1+2,6+2,6
Nominal cooling
performance 6,10 [kW]
Indoor unit 5,3kW can not be a cassette or duct unit
MULTI DC INVERTER 1 X 3
M3OC-27HRDN1
1-indoor
unit [kW]
2-indoor units
[kW]
3-indoor units
[kW]
2,1 2,1+2,1 2,6+2,6 3,5+5,3 2,1+2,1+2,1 2,1+2,6+3,5 2,6+2,6+3,5
2,6 2,1+2,6 2,6+3,5 2,1+2,1+2,6 2,1+2,6+3,5 2,6+3,5+3,5
3,5 2,1+3,5 2,6+5,3 2,1+2,1+3,5 2,1+3,5+3,5
5,3 2,1+5,3 3,5+3,5 2,1+2,1+5,32 2,6+2,6+2,6
Nominal cooling
performance 7,80 [kW]
Indoor unit 5,3kW can not be a cassette or duct unit
Centrum Klima S.A.
8
MULTI DC INVERTER 1 X 4
M4OC-27HRDN1
1-indoor unit
[kW]
2-indoor units
[kW]
3-indoor units
[kW]
2,1 2,1+2,1 2,6+2,6 3,5+5,3 2,1+2,1+2,1 2,1+2,6+3,5 2,1+3,5+3,5 2,6+3,5+3,5
2,6 2,1+2,6 2,6+3,5 5,3+5,3 2,1+2,1+2,6 2,1+2,6+3,5 2,6+2,6+2,6 2,6+3,5+5,3
3,5 2,1+3,5 2,6+5,3 2,1+2,1+3,5 2,1+3,5+3,5 2,6+2,6+3,5 3,5+3,5+3,5
5,3 2,1+5,3 3,5+3,5 2,1+2,1+5,32 2,6+2,6+2,6 2,6+2,6+5,3
Nominal cooling
performance 7,80 [kW]
4-indoor units
[kW]
2,1+2,1+2,1+2,1 2,1+2,1+2,6+2,6 2,1+2,6+2,6+3,5
2,1+2,1+2,1+2,6 2,1+2,1+2,6+3,5 2,1+2,6+3,5+3,5
2,1+2,1+2,1+3,5 2,1+2,1+3,5+3,5 2,6+2,6+2,6+2,6
2,1+2,1+2,1+5,3 2,1+2,6+2,6+2,6 2,6+2,6+2,6+3,5
MULTI DC INVERTER 1 X 4
M4OC-36HRDN1
1-indoor unit
[kW]
2-indoor units
[kW]
3-indoor units
[kW]
2,1 2,1+2,1 2,6+2,6 3,5+5,3 2,1+2,1+2,1 2,1+2,6+3,5 2,1+3,5+3,5 2,6+2,6+5,3 3,5+3,5+3,5
2,6 2,1+2,6 2,6+3,5 5,3+5,3 2,1+2,1+2,6 2,1+2,6+3,5 2,1+5,3+5,3 2,6+3,5+3,5 3,5+3,5+5,3
3,5 2,1+3,5 2,6+5,3 2,1+2,1+3,5 2,1+3,5+3,5 2,6+2,6+2,6 2,6+3,5+5,3 3,5+5,3+5,3
5,3 2,1+5,3 3,5+3,5 2,1+2,1+5,32 2,6+2,6+2,6 2,6+2,6+3,5 2,6+5,3+5,3
Nominal cooling
performance 10,40 [kW]
4-indoor units
[kW]
2,1+2,1+2,1+2,1 2,1+2,1+2,6+2,6 2,1+2,1+3,5+5,3 2,1+2,6+2,6+5,3 2,1+3,5+3,5+3,5 2,6+2,6+2,6+5,3 2,6+3,5+3,5+5,3
2,1+2,1+2,1+2,6 2,1+2,1+2,6+3,5 2,1+2,1+5,3+5,3 2,1+2,6+3,5+3,5 2,1+3,5+3,5+5,3 2,6+2,6+3,5+3,5 3,5+3,5+3,5+3,5
2,1+2,1+2,1+3,5 2,1+2,1+2,6+5,3 2,1+2,6+2,6+2,6 2,1+2,6+3,5+5,3 2,6+2,6+2,6+2,6 2,6+2,6+3,5+5,3 3,5+3,5+3,5+5,3
2,1+2,1+2,1+5,3 2,1+2,1+3,5+3,5 2,1+2,6+2,6+3,5 2,1+2,6+5,3+5,3 2,6+2,6+2,6+3,5 2,6+3,5+3,5+3,5
9
Air conditioner catalog R410A DC INVERTER (MULTI)
Indoor wall-mounted
MODEL
MULTI R410A DC INVERTER
MSHI-07HRIN1 MSHI-09HRIN1 MSHI-12HRIN1 MSHI-18HRDN1
Energy class A A A A
E ciency kW
Cooling 2,10 2,64 3,50 5,30
Heating 2,50 3,00 4,10 5,25
Rated current A
Cooling 0,15 0,16 0,20 0,24
Heating 0,15 0,16 0,20 0,24
Rated power kW
Cooling 0,035 0,038 0,042 0,052
Heating 0,035 0,040 0,042 0,052
Noise level dB(A) 40 40 41 43
Net weight kg 8,0 8,5 10,0 11,5
Air ow volume m
3
/h 570 570 675 850
Dehumidifying capacity L/h 0,7 0,8 1,2 2,0
Refrigerant pipes diameter inches
Liquid 1/4 1/4 1/4 1/4
Gas 3/8 3/8 1/2 1/2
Power supply V/Hz 230/50 230/50 230/50 230/50
Dimensions [WxHxD] mm 750250205 750250205 815280215 920292224
S
P
E
C
Y
F
I
C
A
T
I
O
N
FUNCTIONS
C
DC AUTO
Turbo
HEATING COOLING FAN AUTO
DC INVERTER AUTORESTART REMOTE CONTROL SLEEP
TIMER SWING MULTI TURBO
Energy class is a measure of operating
e ciency and power consumption under
prescribed conditions. Energy class is
denoted with letters from A through Z. A
class equipment uses energy in the most
e ciently. Therefore, we try to ensure
that all our equipment belong to the A
Energy calss.
WORTH KNOWING:
Centrum Klima S.A.
10
Indoor duct units
MODEL MST2I-18HRDN1
Energy class A
E ciency kW
Cooling 5,30
Heating 6,20
Rated current A
Cooling 0,27
Heating 0,27
Rated power kW
Cooling 0,060
Heating 0,060
Noise level dB(A) 41
Net weight kg 18
Air ow volume m
3
/h 870
Static pressure Pa 10
Dehumidifying capacity L/h 2,3
Refrigerant pipes diameter inches
Liquid 1/4
Gas 1/2
Power supply V/Hz 230/50
Dimensions [WxHxD] mm 1224206365
S
P
E
C
Y
F
I
C
A
T
I
O
N
R410A DC INVERTER (MULTI)
C
DC AUTO
Turbo
FUNCTIONS
HEATING COOLING AUTO
DC INVERTER AUTORESTART REMOTE CONTROL SLEEP
TIMER TURBO MULTI
FAN
The 3 year guarantee is conditioned by
replacement of lters and regular serv-
icing of the unit. Filters must be cleaned
and inside of the indoor unit disinfected.
Dust and other residue present in ambient
air combined with water from condensate
are ideal for bacteria and microorganisms
responsible for unpleasant smell. This prob-
lem can be eliminated by cleaning lters
and inside of the units during regular serv-
icing operations.
WORTH KNOWING:
11
Air conditioner catalog
Turbo
R410A DC INVERTER (MULTI)
Indoor cassette units
MODEL MSQ4I-09HRDN1 MSQ4I-12HRDN1 MSQ4I-18HRDN1
Energy class A A A
E ciency kW
Cooling 2,64 3,50 5,30
Heating 3,00 4,30 6,20
Rated current A
Cooling 0,16 0,18 0,37
Heating 0,16 0,18 0,37
Rated power kW
Cooling 0,038 0,040 0,080
Heating 0,038 0,040 0,080
Noise level dB(A) 36 40 42
Net weight kg 18,0 18,5 21,0
Air ow volume m
3
/h 580 630 790
Dehumidifying capacity L/h 1,2 1,6 2,0
Refrigerant pipes diameter inches
Liquid 1/4 1/4 1/4
Gas 3/8 1/2 1/2
Power supply V/Hz 230/50 230/50 230/50
Dimensions panel [WxHxD] mm 65020650 65020650 65020650
Dimensions case [WxHxD] mm 580254580 580254580 580254580
S
P
E
C
Y
F
I
C
A
T
I
O
N
C DC
AUTO
FUNCTIONS
HEATING COOLING AUTO DC INVERTER
AUTORESTART REMOTE CONTROL SLEEP TIMER SWING
PUMP TURBO MULTI
FAN
The AC unit can also operate in HEATING
mode, delivering heat to the room. In
Heating mode, the unit runs in reverse:
the indoor unit heats, and outdoor cools,
or simply speaking, the outdoor unit
pumps out heat from the ambient air
and transfers it indoor.
WORTH KNOWING:
Centrum Klima S.A.
12
R410A DC INVERTER (MULTI)
Outdoor units: M2OC-18HRDN1, M3OC-27HRDN1
S
P
E
C
Y
F
I
C
A
T
I
O
N
MODEL OUTDOOR UNITS M2OC-18HRDN1 M3OC-21HRDN1 M3OC-27HRDN1
I II I II III I II III
Energy class A A A
E ciency kW
Cooling 2,02~3,45 5,20 (4,34~5,50) 2,05~3,50 4,10~5,30 6,10 (5,30~7,30) 2,02~3,45 4,62~5,50 7,80 (6,36~8,10)
Heating 2,89~4,05 6,07 (4,91~6,36) 2,64~4,10 5,10~5,80 6,70 (6,20~7,60) 2,89~4,05 6,93~7,80 8,67 (7,22~8,96)
EER Cooling 3,21 3,22 3,25
COP Heating 3,55 3,62 3,62
Rated current A
Cooling 4,50~5,00 7,50 4,50~5,80 6,70~8,00 8,60 4,60~6,00 8,50~10,00 11,00
Heating 5,00~6,00 7,60 4,90~6,50 7,40~8,40 8,40 5,30~6,70 9,00~10,60 11,20
Rated power kW
Cooling 1,00~1,20 1,62 1,00~1,30 1,50~1,78 1,91 1,00~1,30 1,80~2,20 2,40
Heating 1,05~1,25 1,67 1,10~1,45 1,65~1,88 1,88 1,15~1,45 1,95~2,30 2,42
Noise level dB(A) Outdoor units 53 55 55
Operating temperature range C Outdoor units -15 ~ +24 -15 ~ +24 -15 ~ +24
Net weight kg Outdoor units 60 55 62
Quantity of agent g R410A 1700 1450 2100
Refrigerant pipes diameter inches
Liquid 2 1/4 3 1/4 3 1/4
Gas 2 3/8 3 3/8 3 3/8
Max lenght refrigerant
pipes
m 30 45 45
Max lenght refrigerant
pipes between units
m 15 15 15
Max. level dierence
units
m 10 10 10
Power supply V/Hz Outdoor units 230/50 230/50 230/50
Dimensions [WxHxD] mm Outdoor units 845695335 845695335 845695335
Brand compressor SANYO TOSHIBA SANYO
FUNCTIONS
DC AUTO
DC INVERTER AUTORESTART MULTI
Correct placement of the outdoor unit is very important. It should
be mounted in the shade, away from direct sunlight. Adequate
ventilation is also important, as the outdoor unit is responsible
for pumping out the heat from inside. Poor ventilation or direct
sunlight can signicantly impair the systems e ciency.
WORTH KNOWING:
13
Air conditioner catalog
Outdoor units: M4OC-27HRDN1, M4OC-36HRDN1
S
P
E
C
Y
F
I
C
A
T
I
O
N
MODEL OUTDOOR UNIT M4OC-27HRDN1 M4OC-36HRDN1
I II III IV I II III IV
Energy class A A
E ciency kW
Cooling 2,02~5,20 4,04~6,93 6,06~7,51 7,80 (7,80~8,96) 2,02~5,20 4,04~10,40 6,06~12,13 10,40 (8,10~12,43)
Heating 2,60~5,20 4,62~7,22 6,06~7,80 8,67 (8,67~9,83) 2,60~5,20 4,62~10,70 6,93~12,42 10,98 (8,67~13,01)
EER Cooling 3,21 3,04
COP Heating 3,61 3,28
Rated current A
Cooling 5,80~7,80 7,50~10,70 9,70~12,10 11,20 5,80~7,70 7,50~10,70 9,70~12,10 15,50
Heating 7,20~11,00 9,30~14,90 12,90~15,30 11,10 7,20~11,00 9,30~14,90 12,90~15,30 15,20
Rated power kW
Cooling 1,33~1,78 1,73~2,40 2,23~2,78 2,47 1,33~2,38 1,73~2,70 2,23~2,98 3,45
Heating 1,65~2,52 2,13~3,45 2,96~3,52 2,44 1,65~2,52 2,53~3,52 3,46~3,92 3,38
Noise level dB(A) Outdoor units 57 61
Operating temperature range C Outdoor units -15 ~ +24 -15 ~ +24
Net weight kg Outdoor units 78 93
Quantity of agent g R410A 2400 2700
Refrigerant pipes diameter inches
Liquid 4 1/4 4 1/4
Gas 4 3/8 4 3/8
Max lenght refrigerant pipes m 60 60
Max lenght refrigerant pipes
between units
m 15 20
Max. level dierence units m 10 10
Power supply V/Hz Outdoor units 230/50 230/50
Dimensions [WxHxD] mm Outdoor units 895860330 990996396
Brand compressor MITSUBISHI MITSUBISHI
R410A DC INVERTER (MULTI)
FUNCTIONS
DC AUTO
DC INVERTER AUTORESTART MULTI
All MULTI DC INVERTER AC units are equipped with heat pumps
and are able to maintain optimum temperature throughout the
year. When it gets colder outside, they can substitute other
heating sources. They can operate in temperatures as low as
-15C.
WORTH KNOWING:
Centrum Klima S.A.
14
Duct air conditioners
MODEL
INDOOR UNIT MTA3-48HRDN1 MTA-60HRDN1
OUTDOOR UNIT MOU-48HRDN1 MOU-60HRDN1
Energy class A A
E ciency (min./nom./max.) kW
Cooling 3,80-14,00-16,00 4,40-16,00-17,20
Heating 4,50-15,47-17,20 5,00-17,60-18,00
EER Cooling 3,25 3,22
COP Heating 3,67 3,67
Rated current (min./nom./max.) A
Cooling 3,60-6,30-8,50 4,30-7,20-11,50
Heating 3,30-6,09-7,90 3,80-6,9610,60
Rated power (min./nom./max.) kW
Cooling 2,50-4,35-6,00 3,00-4,97-7,50
Heating 2,30-4,20-5,60 2,60-4,80-6,90
Noise level dB(A)
Indoor unit 45 45
Outdoor unit 54 54
Net weight kg
Indoor unit 62 62
Outdoor unit 115 115
Air ow volume m
3
/h 2460 2880
Static pressure Pa 96 96
Dehumidifying capacity L/h 5,0 6,1
Quantity of agent g R410A 3850 3850
Refrigerant pipes diameter
inches Liquid 3/8 3/8
Gas 5/8 5/8
Max lenght refrigerant pipes m 50 50
Max. level dierence units m 30 30
Power supply V/Hz
Indoor unit 230/50 230/50
Outdoor unit 380/50 380/50
Dimensions [WxHxD] mm
Indoor unit 1350298800 1350320800
Outdoor unit 9401245400 9401245400
S
P
E
C
Y
F
I
C
A
T
I
O
N
R410A DC INVERTER
FUNCTIONS
C DC AUTO
HEATING COOLING AUTO DC INVERTER AUTORESTART
Turbo
REMOTE CONTROL SLEEP TIMER TURBO
FAN
Units with SLEEP mode are designed for
operation at night, when noise can be par-
ticularly disturbing. At night their fans and
compressors operate a lowest possible
rpm.
WORTH KNOWING:
OPTION
WALL CONTROLLER
15
Air conditioner catalog R410A DC INVERTER
Cassette air conditioners
MODEL
INDOOR UNIT MCA-12HRDN1 MCA-18HRDN1 MCC-24HRDN1 MCC-36HRDN1
OUTDOOR UNIT MOU-12HRDN1 MOU-18HRDN1 MOU-24HRDN1 MOU-36HRDN1
Energy class B A A A
E ciency (min./nom./max.) kW
Cooling 1,40-3,50-4,00 1,63-5,27-5,65 1,59-7,03-7,85 2,90-10,50-12,40
Heating 1,40-4,00-4,75 1,45-5,86-6,15 1,70-7,76-8,50 3,70-11,03-13,20
EER Cooling 3,24 3,24 3,23 3,25
COP Heating 3,60 3,69 3,69 3,66
Rated current (min./nom./max.) A
Cooling 2,00-5,10-12,00 2,47-7,04-12,30 4,26-9,48-13,20 10,00-14,13-25,00
Heating 2,00-5,20-12,00 3,13-6,70-11,07 4,56-9,13-12,23 8,70-14,00-23,64
Rated power (min./nom./max.) kW
Cooling 0,38-1,08-2,55 0,57-1,62-2,60 0,98-2,18-2,80 2,30-3,25-5,50
Heating 0,38-1,12-2,55 0,72-1,54-2,34 0,95-2,10-2,70 2,00-3,20-5,20
Noise level dB(A)
Indoor unit 37 41 42 44
Outdoor unit 48 51 53 55
Net weight kg
Outdoor unit 21 21 29 36
Outdoor unit 40 59 72 107
Air ow volume m
3
/h 680 800 1010 1120
Dehumidifying capacity L/h 1,6 2,0 3,6 5,0
Quantity of agent g R410A 1500 1700 2200 2900
Refrigerant pipes diameter inches
Liquid 1/4 1/4 3/8 3/8
Gas 1/2 1/2 5/8 5/8
Max lenght refrigerant pipes m 25 25 25 30
Max. level dierence units m 15 15 15 20
Power supply V/Hz
Indoor unit
230/50 230/50 230/50
230/50
Outdoor unit 380/50
Dimensions panel [WxHxD] mm Indoor unit 65030650 65030650 95046950 95046950
Dimensions [WxHxD] mm
Indoor unit 580254580 580254580 840230840 840300840
Outdoor unit 761593315 842695324 895862355 990966396
S
P
E
C
Y
F
I
C
A
T
I
O
N
C
AUTO
HEATING COOLING AUTO
AUTORESTART REMOTE CONTROL SLEEP TIMER SWING
FUNCTIONS
Turbo
TURBO
DC
DC INVERTER FAN
The principal objective of any AC system
is to maintain a climate comfortable to the
user. One condition of comfort is good qual-
ity of air particularly oxygen contents
and thermal comfort. AC rooms oer the
optimum temperature and good humid-
ity level.
WORTH KNOWING:
OPTION
WALL CONTROLLER
PUMP
Centrum Klima S.A.
16
Wall conditioners
R410A DC INVERTER
FUNCTIONS
C DC AUTO
HEATING COOLING AUTO DC INVERTER AUTORESTART
Turbo
REMOTE CONTROL SLEEP TIMER TURBO
FAN
Installation is the major factor aecting cor-
rect operation of any AC unit. Installation
should be performed by trustworthy, certied
and experienced specialists. Independent
installation can result in loss of guarantee
cover and may lead to faulty operation of the
unit. The installer should conrm installation
by relevant entry in the guarantee card.
WORTH KNOWING:
MODEL UNIT MSH-09HRDN1-QC2(D) MSH-12HRDN1-QC2(D) MSH-18HRDN1-QC2(B) MSH-24HRDN1-QCOW(B)
Energy class A A A A
E ciency
(min./nom./max.)
kW
Cooling 2,64 (1,40-3,30) 3,80 (1,50-4,10) 5,30 (1,60-6,40) 7,00 (3,50-7,30)
Heating 3,00 (1,50-3,80) 4,10 (1,60-4,32) 5,25 (1,70-6,70) 7,30 (3,30-7,80)
EER Cooling 3,22 3,23 3,21 3,21
COP Heating 3,62 3,63 3,61 3,61
Rated current
(min./nom./max.)
A
Cooling 1,00-3,60-4,70 1,50-4,80-5,00 1,80-7,30-10,20 3,60-9,80-11,20
Heating 1,00-3,50-4,20 1,50-4,60-4,80 1,60-6,80-9,50 3,50-9,10-12,00
Rated power
(min./nom./max.)
kW
Cooling 0,23-0,82-1,07 0,35-1,09-1,17 3,80-1,64-2,30 0,82-2,19-2,50
Heating 0,23-0,81-0,96 0,35-1,05-1,10 0,35-1,50-2,10 0,80-2,03-2,70
Noise level
(min./nom./max.)
dB(A)
Indoor unit 28/33/39 29/35/40 37/40/45 41/45/48
Outdoor unit 52 53 56 58
Net weight kg
Indoor unit 7,5 9,5 11,5 15,5
Outdoor unit 27,5 29,0 40,5 49,5
Air ow volume m
3
/h 570 670 850 1150
Dehumidifying capacity L/h 1,0 1,2 1,5 2,2
Quantity of agent g R410A 660 1000 1180 1950
Refrigerant pipes diameter inches
Liquid 1/4 1/4 1/4 1/4
Gas 3/8 3/8 3/8 3/8
Power supply V/Hz
Indoor unit
230/50 230/50 230/50 230/50
Outdoor unit
Dimensions [WxHxD] mm
Indoor unit 750x250x205 815x280x215 920x292x224 1080x330x225
Outdoor unit 695x531x257 635x531x257 760x590x285 845x695x335
S
P
E
C
Y
F
I
C
A
T
I
O
N
17
Air conditioner catalog R410A
Wall conditioners
Seria KING K1
MODEL AUS-09H53R150K1 AUS-12H53R130K1
Energy class A A
E ciency kW
Cooling 2,70 3,50
Heating 2,70 3,80
EER Cooling 3,38 3,33
COP Heating 3,38 3,43
Rated current A
Cooling 3,60 4,65
Heating 3,60 4,88
Rated power kW
Cooling 0,80 1,05
Heating 0,80 1,10
Noise level dB(A)
Indoor unit 35 39
Outdoor unit 50 52
Net weight kg
Indoor unit 10 10
Outdoor unit 30 37
Air ow volume m
3
/h 450 500
Dehumidifying capacity L/h 0,8 1,2
Quantity of agent g R410A 850 1280
Refrigerant pipes diameter inches
Liquid 1/4 1/4
Gas 3/8 1/2
Power supply V/H
Indoor unit
230/50 230/50
Outdoor unit
Dimensions [WxHxD] mm
Indoor unit 840273160 840273160
Outdoor unit 745552328 835552310
S
P
E
C
Y
F
I
C
A
T
I
O
N
FUNCTIONS
C AUTO
HEATING COOLING AUTO AUTORESTART
REMOTE CONTROL SLEEP TIMER SWING
Heating with the unit in HEATING mode is
a lot more e cient than in case of electric
heaters. This is due to high energy e -
ciency of AC units reaching 3,6. This rate
means that by using just 1 kWh of electricity
the unit can generate 3,6 kWh of heath
delivered to the room. Electric heaters are
far less e cient, in fact they generate less
heat than they take.
WORTH KNOWING:
FAN
Centrum Klima S.A.
18
Wall conditioners
R410A
L6/D6 GALAXY
L17/D17 FLORID
MODEL
GALAXY AUS-09H53R010L6 AUS-12H53R150L6 AUS-18H53R120D6 AUS-24H53R230G4
FLORID AUS-09H53R010L17 AUS-12H53R150L17 AUS-18H53R120D17
Energy class B C C B
E ciency kW
Cooling 2,50 3,50 5,10 7,00
Heating 2,75 3,90 5,80 7,30
EER Cooling 2,78 2,82 2,82 3,02
COP Heating 3,40 3,22 2,97 3,04
Rated current A
Cooling 4,10 5,67 8,00 10,00
Heating 3,70 5,50 8,70 10,40
Rated power kW
Cooling 0,90 1,24 1,81 2,32
Heating 0,81 1,21 1,95 2,40
Noise level dB(A)
Indoor unit 40 40 46 51
Outdoor unit 50 52 54 60
Net weight kg
Indoor unit 10 10 12 15
Outdoor unit 26 31 41 60
Air ow volume m
3
/h 400 460 850 1100
Dehumidifying capacity L/h 0,8 1,6 2,2 2,3
Quantity of agent g R410A 650 820 1350 1840
Refrigerant pipes diameter inches
Liquid 1/4 1/4 1/4 3/8
Gas 3/8 3/8 1/2 5/8
Power supply V/Hz
Indoor unit
230/50 230/50 230/50 230/50
Outdoor unit
Dimensions [WxHxD] mm
Indoor unit 800290196 800290196 860292205 1080330220
Outdoor unit 910x690x370 910x690x370 830530320 910690370
G4 GALAXY
S
P
E
C
Y
F
I
C
A
T
I
O
N
FUNCTIONS
C AUTO
HEATING COOLING AUTO AUTORESTART
REMOTE CONTROL SLEEP TIMER SWING
The most common cause of failures are at
batteries of the remote control. Since only
strong signal sent by the remote can be read
by the indoor unit, condition of the batteries
indicated on the remote display needs to be
checked. Used batteries must be disposed of
responsibly.
WORTH KNOWING:
FAN
19
Air conditioner catalog
Wall conditioners
R410A
Galaxy DUALSPLIT
MODEL AUS-09+12H53R230L6
Energy class A
E ciency kW
Cooling 2,50 + 3,50
Heating 2,75 + 3,90
EER Cooling 2,78/2,82
COP Heating 3,40/3,22
Rated current A
Cooling 4,10 + 5,67
Heating 3,70 + 5,50
Rated power kW
Cooling 0,90 + 1,24
Heating 0,81 + 1,21
Noise level dB(A)
Indoor unit 40/40
Outdoor unit 59
Net weight kg
Indoor unit 10/10
Outdoor unit 56
Air ow volume m
3
/h 400/460
Dehumidifying capacity L/h 0,8/1,6
Quantity of agent g R410A 650/820
Refrigerant pipes diameter
in-
ches
Liquid 1/4
Gas 3/8
Power supply V/Hz
Indoor unit
230/50
Outdoor unit
Dimensions [WxHxD] mm
Indoor unit 800290196
Outdoor unit 910x690x370
S
P
E
C
Y
F
I
C
A
T
I
O
N
FUNCTIONS
C AUTO
HEATING COOLING AUTO AUTORESTART
REMOTE CONTROL SLEEP TIMER SWING
FAN
DUALSPLIT
2 INDOOR UNITS + 1 OUTDOOR UNIT
L6
L6
Centrum Klima S.A.
20
S
P
E
C
Y
F
I
C
A
T
I
O
N
MODEL GD-18HMR/U GD-36HMRS/U GD-48HMRS/U GD-60HMRS/U
E ciency kW
Cooling 5,30 10,50 14,10 17,60
Heating 5,80 11,60 15,50 19,30
Rated current A
Cooling 8,10 6,70 8,90 10,20
Heating 8,20 6,80 9,00 10,50
EER Cooling 2,88 2,82 2,72 2,76
COP Heating 3,09 2,86 2,81 2,81
Rated power kW
Cooling 1,84 3,72 5,04 5,80
Heating 1,87 4,06 5,51 6,40
Noise level
(min./nom./max.)
dB(A)
Indoor unit 38/40/42 41/43/45 48/50/52 51/53/55
Outdoor unit 55 62 62 63
Net weight kg
Indoor unit 30 44 60 60
Outdoor unit 50 80 85 110
Air ow volume m
3
/h 850 1550 2300 2500
Static pressure Pa 50 70 70 70
Dehumidifying capacity L/h 2,61 3,83 4,46 5,2
Quantity of agent g R410A 1800 2800 3300 3800
Refrigerant pipes diameter inches
Liquid 1/4 3/8 3/8 3/8
Gas 1/2 3/4 3/4 3/4
Max lenght refrigerant pipes m 25 30 50 50
Max. level dierence units m 10 15 30 30
Power supply V/Hz 230/50 380/50 380/50 380/50
Dimensions [WxHxD] mm
Indoor unit 850x250x745 1055x295x755 1385x312x830 1385x312x830
Outdoor unit 800x670x300 880x790x360 970x928x345 973x1239x350
Duct air conditioners
R410A
FUNCTIONS
C
AUTO
HEATING COOLING AUTO
AUTORESTART REMOTE CONTROL
SLEEP
TIMER
FAN
EVAPORATOR is dierent from Air Condi-
tioning. The main difference is that the
evaporator lowers temperature by evapo-
rating water, whereas AC removes heat by
evaporating cooling media circulating in the
system. For this reason, cooling e ciency of
the evaporator is limited and not su cient
to maintain thermal comfort. Further, evapo-
rator causes increased level of humidity,
with possibly negative impact on people
staying in the room.
WORTH KNOWING:
OPTION
WALL CONTROLLER
21
Air conditioner catalog R410A
Klimatyzatory kasetonowe
FUNCTIONS
C AUTO
HEATING COOLING AUTO AUTORESTART
REMOTE CONTROL SLEEP TIMER SWING PUMP
FAN
Portable AC units can be used immediately
after taking out of the box, without any
installation. All it takes is to connect the
unit to power, connect the heat-removal
duct and enjoy the cool. The unit has its
condensate tank and is remotely controlled
for improved comfort.
WORTH KNOWING:
S
P
E
C
Y
F
I
C
A
T
I
O
N
MODEL GC-18HR GC-24HR GC-36HRS GC-48HRS
E ciency kW
Cooling 5,30 7,00 10,50 14,10
Heating 5,80 7,62 12,20 15,50
Rated current A
Cooling 8,20 11,80 6,70 8,90
Heating 8,90 11,20 6,50 9,10
EER Cooling 2,91 2,89 2,80 2,73
COP Heating 3,12 3,26 3,20 3,05
Rated power kW
Cooling 1,82 2,46 3,75 5,12
Heating 1,86 2,34 3,81 5,08
Noise level
(min./nom./max.)
dB(A)
Indoor unit 38/40/42 31/45/51 41/48/52 41/48/52
Outdoor unit 56 58 62 62
Net weight kg
Indoor unit 23 27 33 33
Outdoor unit 50 64 70 85
Air ow volume m
3
/h 750 1200 1600 1800
Dehumidifying capacity L/h 2,55 3,15 4,10 4,26
Quantity of agent g R410A 1800 2200 2800 3300
Refrigerant pipes diameter inches
Liquid 1/4 3/8 3/8 3/8
Gas 1/2 5/8 3/4 3/4
Max lenght refrigerant pipes m 25 30 30 50
Max. level dierence units m 10 15 15 30
Power supply V/Hz 230/50 230/50 380/50 380/50
Dimensions panel [WxHxD] mm Indoor unit 650x30x650 953x40x953 953x40x953 953x40x953
Dimensions [WxHxD] mm
Indoor unit 570x255x570 840x230x840 840x300x840 840x300x840
Outdoor unit 800x670x300 845x680x310 880x790x360 970x928x345
OPTION
WALL CONTROLLER
Centrum Klima S.A.
22
Ceiling - oor air conditioners
R410A
FUNCTIONS
Many interior designers will not even think of
installing an A/C unit on the wall or near the
ceiling. Instead, they can use oor-mounted
units. Their versatility makes them a viable
option where other solutions cannot be ap-
plied for various reasons. They are particularly
handy under windows, on ceilings and in at-
tics. They are a perfect solution for shops,
restaurants and o ces. They can be easily
blended in the background, operate quietly
and have attractive design.
WORTH KNOWING:
C
AUTO
HEATING COOLING AUTO
AUTORESTART REMOTE CONTROL SLEEP TIMER
FAN
S
P
E
C
Y
F
I
C
A
T
I
O
N
MODEL GU-24HRT/AU GU-36HRT/AU GU-48HRT/AU GU-60HRT/AU
E ciency kW
Cooling 7,00 10,50 14,08 17,60
Heating 7,74 12,50 14,70 19,30
Rated current A
Cooling 11,00 6,70 8,90 10,20
Heating 11,30 7,00 9,20 10,40
EER Cooling 2,83 2,81 2,79 2,77
COP Heating 3,00 2,97 2,89 2,90
Rated power kW
Cooling 2,51 3,74 5,02 5,78
Heating 2,58 3,91 5,35 6,20
Noise level
(min./nom./max.)
dB(A)
Indoor unit 42/44/46 45/47/49 48/50/52 49/51/53
Outdoor unit 58 62 62 63
Net weight kg
Indoor unit 34 45 56 70
Outdoor unit 64 80 85 110
Air ow volume m
3
/h 1200 1700 2200 2600
Dehumidifying capacity L/h 2,93 3,88 4,50 5,20
Quantity of agent g R410A 1800 2800 3300 3800
Refrigerant pipes diameter inches
Liquid 3/8 3/8 3/8 3/8
Gas 5/8 3/4 3/4 3/4
Max lenght refrigerant pipes m 30 30 50 50
Max. level dierence units m 15 15 30 30
Power supply V/Hz 230/50 380/50 380/50 380/50
Dimensions [WxHxD] mm
Indoor unit 1016X630X240 1316X630X240 1616X630X240 1916X630X240
Outdoor unit 845X680X310 880X790X360 970X928X345 973X1239X350
OPTION
WALL CONTROLLER
23
Air conditioner catalog
MODEL AUF-48H58R520D
E ciency kW
Cooling 14,00
Heating 16,00
EER Cooling 2,75
COP Heating 2,90
Rated current A
Cooling 11,30
Heating 12,50
Rated power kW
Cooling 5,09
Heating 5,52
Noise level dB(A)
Indoor unit 55
Outdoor unit 59
Net weight kg
Indoor unit 60
Outdoor unit 85
Air ow volume m
3
/h 1800
Dehumidifying capacity L/h 6,0
Quantity of agent g R410A 4200
Refrigerant pipes diameter inches
Liquid 3/8
Gas 3/4
Max lenght refrigerant pipes m 10
Max. level dierence units m 5
Power supply V/Hz
Indoor unit 230/50
Outdoor unit 380/50
Dimensions [WxHxD] mm
Indoor unit 6051900330
Outdoor unit 955x1030x413
Floor air conditioners
S
P
E
C
Y
F
I
C
A
T
I
O
N
R410A
FUNCTIONS
C
HEATING COOLING AUTO
REMOTE CONTROL SLEEP TIMER SWING
FAN
Every one of as uses more than 10.000 liters
of air every day. Clean air to a large extent
determines our wellbeing. Mistral and Galanz
A/C units are quipped with new generation
Tio2 bacteria lters eliminating microorgan-
isms, and pre-lters removing dust and other
debris.
WORTH KNOWING:
Centrum Klima S.A.
24
Portable air conditioners
MODEL AM-09C53CD1 AM-12C53CA1
E ciency kW Cooling 2,50 3,00
Rated current A Cooling 4,10 7,20
Rated power kW Cooling 0,95 1,15
Noise level dB(A) 52 56
Area of operation (max.) m
2
16 20
Net weight kg 33 39
Air ow volume m
3
/h 340 450
Dehumidifying capacity L/h 1,2 2,6
Power supply V/Hz 230/50 230/50
Dimensions [WxHxD] mm 470635470 388770605
S
P
E
C
Y
F
I
C
A
T
I
O
N
FUNCTIONS
R407C
AM-09C53CD1 AM-12C53CA1
COOLING REMOTE CONTROL TIMER
SWING CONDENSATE TANK HAR
Setting too low temperature air conditioner
may have a negative impact adversely the
health of users. Appropriate range summer
temperatures should fall in the range of
24 C to 28 C. It is Note that the room
temperature should not be signicantly
lower than outside, preferably in the range
than 5-7 C. Too much dierence can lead
to colds.
WORTH KNOWING:
FAN
25
Air conditioner catalog
Assembly accessories
REFRIGERANT COPPER PIPE, UNINSULATED
REFRIGERANT COPPER PIPE, INSULATED
DIAMETER WALL THICKNESS LENGTH
mm inches mm m
6 1/4 0,76 25
9 3/8 0,81 25
12 1/2 0,81 25
16 5/8 0,89 25
19 3/4 0,89 25
Copper pipe made to UNI-EN 12735-1 standard;
Used for distribution of the refrigerants. Annealed in coils;
Ends plugged to preserve clan and dry interior.

Copper tube, according to UNI-EN 12735-1. Designed for distribution of


cooling media. Heat-treated in coils, with both ends closed to maintain
dry and clean inside surface. It is pre-insulated with PE sleeve, accord-
ing to UNI-EN 10376, CFC and HCFC free, as required under CEE/UE
2037/2000.
Adequate layer of insulation prevents condensation of water: temperature
of media in the tube not lower than 7C, inside room temperature 27C,
indoor relative humidity less than 50%.
Insulation specications:
Water diusion resistance = 6100;
Thermal conductivity 40C: 0,038 W/mK;
Insulation material density: 33,3 Kg/m
3
;
Fire resistance class 1 acc. to D.M. 26/06/1984 as amended by D.M.
03/09/2001;
Not containing CFC or (HCFC);
Marking at every meter of length.

REFRIGERANT COPPER PIPE, INSULATED


DIAMETER WALL THICKNESS LENGTH
mm inches mm m
6 1/4 0,8 25
9 3/8 0,8 25
12 1/2 0,8 25
16 5/8 1,0 25
19 3/4 1,0 25
22 7/8 1,0 25
REFRIGERANT COPPER PIPE, INSULATED DOUBLE
DIAMETER WALL THICKNESS LENGTH
mm inches mm m
6+9 1/4+3/8 0,8+0,8 25
6+12 1/4+1/2 0,8+0,8 25
9+16 3/8+5/8 0,8+1,0 25
Centrum Klima S.A.
26
REFRIGERANTS
Type Package
Cylinder size
10 20
R407C
Reusable
cylinder
11kg 25kg
R410A 11kg 25kg
R134A 11kg 25kg
R404A 11kg 25kg
FRIGO KFLEX ST
Thickness
(mm)
Length (m)/ package
1/4 3/8 1/2 5/8 3/4
6 50 46 40 38 30
9 40 34 31 27 23
13 26 23 18 17 15
Assembly accessories
RUBBER INSULATION FOR REFRIGERANT PIPES
K-Flex ST Frigo exible insulation sleeve of synthetic rubber foam, in
the form of tubes, without pre-cut opening, coiled. Packed in cartons,
50/50/20 cm. For thermal insulation and prevention of condensation
of indoor AC, cooling and plumbing systems.
Excellent insulation properties = 0,036 W(m*K)
Temperature range -40
o
C maks +116
o
C
-20
o
C = 0,034
Thermal conductivity W/(mK) EN ISO 8497 0
o
C = 0,036
(DIN 52613) +20
o
C = 0,038
Permeability EN 12086 (DIN 52615) 7000
Corrosion DIN 1988/7*; pH neutral
Fire resistance CL. 1 (I) B1 DIN 4102 (D)
BS 476 Part 6 1989 CLO (UK)
Does not contain HCFC and CFC
REFRIGERANTS
A valid safety sheet has been issued for the product, authorizing its
use in Poland.
27
Air conditioner catalog
CONDENSER FIXING SL
Type
A B C Max. load Steel sheet thickness
cm cm cm kg mm
SL 400 39 40 34 110 1,5
SL 430 39 43 35 110 1,6
SL 450 39 45 36 120 1,8
SL 550 49 55 44 170 2,0
CONDENSER FIXING SL
Detachable feet, xed with 3 screws;
Powder-painted (to RAL 1013);
Adjustable position of installation dampers;
Complete set ready for installation (anchor, screws, dampers).

CONDENSER TIES HB
Typ
A B C D Max. load Steel sheet thickness
cm cm cm cm kg mm
HB-380 40 38 32 80 95 1,5
HB-480 42 48 41,5 100 100 1,8
CONDENSER TIES HB
Adjustable cross-beam;
Detachable feet, powder-painted (to RAL 9016);
Adjustable position of installation dampers;
Complete set ready for installation (anchor, screws, dampers).

ROOF TIES - RS
Typ
A B C Max. load
cm cm cm kg
RS 380 380 500 800 110
RS 480 480 500 800 110
RS 550 550 500 1000 200
RS 600 600 550 1000 200
ROOF TIES RS
Detachable feet;
Powder-painted (to RAL 1013);
Adjustable position of installation dampers;
Complete set ready for installation (anchor, screws, dampers).

Assembly accessories
A
B
C
A
D
B
C
A
B
C
Centrum Klima S.A.
28
CONDENSER SUPPORT PVC
Type
Length Maximum load
cm kg
351 SP 35 200
451 SP 45 200
342 TP hole plug
CONDENSER SUPPORT PVC
Assembly accessories
PCV supports;
Corrosion-resistant;
Cellular structure eliminates necessity to use dampers.

DRIP TRAY CCT


A B C
mm mm mm
30 790 355
DRIP TRAY CCT
Powder-coated (to RAL 1013);
Adjustable position of installation dampers;
Complete set ready for installation.

CONDENSATE FLEXIBLE PIPE


Code
Diameter Length
mm m
0016TU 16 30
0018TU 18 30
0020TU 20 30
CONDENSATE FLEXIBLE PIPE
Easy and quick installation without special tools;
Durable material, resistant to the elements;
Flexible structure;
Coil preventing crushing the pipe.

SF CONDENSATE REMOVAL SIPHON


easy and fast installation without special tools;
made of PVC;
horizontal or vertical installation;
universal joint (16, 18 and 20 mm);
design facilitating installation in system ducts;
packs of 10

A
B
C
29
Air conditioner catalog Assembly accessories
EXTERNAL CONDENSATE PUMP HOPPY
External condensate pump;
Compact design (LxHxW) 190150110 mm;
Power supply: 50Hz/230V. Rated power 25W;
Maximum head 3,2 m;
Max capacity 1,8 l/min (108 l/h);
Low noise level. (43 dB(A));
Can remove condensate from several AC units;
Inlet tube diameter: 4 mm; Outlet tube diameter: 6 mm.

BLUE STAR DUCT CONDENSATE REMOVAL PUMP


The pump is mounted in the collection pan;
Small size: 100x50x40 mm (LxHxW);
Power supply: 50Hz / 230 V, power consumption 20 W;
Pumping head: 8 m at 3 l/h;
Suction lift: 1 m;
Maximum output: 18 l/h at 0 m rise;
Includes:
pump, condensate reservoir, power supply and control wiring,
1,5 m vinyl tube, plastic clamps, xing bands.

Possibile applications
1. Over suspended ceiling
2. Inside duct
3. Behind evaporator
1
2
3
Duct
Vinyl tubing
Space over suspended celling
Evaporator
coil pipe
Condensate pan
condensate pipe
pump
air conditioner air conditioner air conditioner
maximum height
H
H
max
=3,2m
Centrum Klima S.A.
30
KORYTO MONTAOWE MIDI
Reference
number
Length A H
Reference number
of appropriate
adjustable coupling
Colour of
adjustable
coupling
m mm mm
0612MD 2 60 45 0603ST yellow
0812MD 2 80 60 0803ST red
1212MD 2 110 75 1203ST green
INSTALLATION TRAY PVC
Reference
number
Length A H
Reference number
of appropriate
adjustable coupling
Colour of
adjustable
coupling
m mm mm
0312BC 2 25 25
0612BC 2 60 45 0603ST yellow
0712BC 2 70 55 0703ST orange
0812BC 2 80 60 0803ST red
0912BC 2 90 65 0903ST blue
1212BC 2 110 75 1203ST green
1412BC 2 140 90 1403ST beige
INSTALLATION TRAY PVC
INSTALLATION TRAY MIDI
Adjustable coupling
A
H
How
to install
the tray
Adjustable coupling
A
H
How to install
the tray
0312BC
0612BC
0712BC
0812BC
0912BC
1212BC
1412BC
0612MD
0812MD
1212MD
Assembly accessories
31
Air conditioner catalog
Ref. No. Width Ref. No. Width
0306 AE 25mm 0806 AE 80mm
0606 AE 60mm 0906 AE 90mm
0706 AE 70mm 1206 AE 110mm
EXTERNAL PVC ANGLE
Ref. No. Width Ref. No. Width
0305 AI 25mm 0805 AI 80mm
0605 AI 60mm 0905 AI 90mm
0705 AI 70mm 1205 AI 110mm
INTERNAL PVC ANGLE
Ref. No. Width Ref. No. Width
0307 CP 25mm 0807 CP 80mm
0607 CP 60mm 0907 CP 90mm
0707 CP 70mm 1207 CP 110mm
PVC BEND
Ref. No. Width Ref. No. Width
0308 TT 25mm 0808 TT 80mm
0608 TT 60mm 0908 TT 90mm
0708 TT 70mm
PVC END CAP
WALL SIDE PVC BEND
Assembly accessories
Ref. No. Width Ref. No. Width
0609 CM 60mm 0809 CM 80mm
0709 CM 70mm 0909 CM 90mm
1209 CM 110mm
Centrum Klima S.A.
32
Ref. No. Width Ref. No. Width
0610 PM 60mm 0810 PM 80mm
0710 PM 70mm 0910 PM 90mm
1210 PM 110mm
PVC THRU-WALL PENETRATION
Ref. No. Width Ref. No. Width
0304 GC 25mm 0804 GC 80mm
0604 GC 60mm 0904 GC 90mm
0704 GC 70mm 1204 GC 110mm
Ref. No. Width
0611 DT 60mm
0811 DT 80mm
PVC CONNECTOR
Ref. No. Width
0813 DT 80mm
0913 DT 90mm
1213 DT 110mm
T PVC CONNECTOR
PVC CONNECTING BAND
Assembly accessories
33
Air conditioner catalog
Products for cleaning air conditioning devices
FRIONETT

CLIM SPRAY FOAM 170ML GC 5990


For cleaning air conditioning equipment (stationary, portable, in
vehicles) and heating appliances (ducts, lters) contains active
foam with cleaning and disinfecting properties;
Fungicidal, disinfectant, deodorant;
Lemon smell. Bulk package containing 12 containers.
Application directions for us:
Ready for immediate use. Special formula removes results of damp-
ness and residues from heating and cooling appliances. Intensive
lemon scent eliminates odor at its source. Shake well before use.
Apply in upright position.
Set the AC unit to ventilation (HIGH). Find air inlet. Apply gener-
ously to the inside of the unit. Switch o for 10 minutes. Repeat if
necessary.
Cleaning draining trays: Remove all residues from the tray. Apply the
agent generously and leave for 10 minutes.
Repeat if necessary.

1.
2.
3.
4.
RECTORSEAL concentrate 3,8l for boiler
EVAPORATOR COIL CLEANER is acid-free grease removal and cleaning
agent for evaporators and air lters. Contains freshening agent remov-
ing any unpleasant smell. Very eective due to unique combination of
organic and inorganic surfactants.
Purpose:
EVAPORATOR COIL CLEANER is intended for cleaning evaporators, air
lters and other metal surfaces where acid-based cleaners cannot be
used. It can be safely applied on aluminum, copper, stainless steel and
washable painted surfaces. Not recommended for electric appliances.
Characteristics:
E ciently removes oil, fat, tobacco stains, dust and other dirt
Liquid concentrate can be diluted with water
Aicd-free, not causing corrosion
Leaves a pleasant smell
Does not require rinsing
Diluting: for normal applications dilute 1:4 in water. 1 bottle can be used
to produce 19 l of cleaning solution.
Volume: 3,8 liter.

CONFORMS TO THE STANDARDS


Bactericidal NFEN 1040
Legionella T 72 300-301
Salmonella T 72 300-301
Listeria T 72 300-301
Fungicidal NFEN 1275
Certicate from the PZH HK/M/0102/02/2005
Centrum Klima S.A.
34
FRIONETT

2 R.T.U. SPRAY 0,95L GC 5989


Eective product for regular maintenance. Contains alkaline foam.
Does not cause corrosion;
It is disinfectant, fungicidal, cleaning and deodorant. For in-door and
out-door applications (evaporators and condensers);
Inammable (water-based), biodegradable;
Bulk package of 12 containers (12x0,95);
Being biodegradable, it can be used in the food industry (cooling rooms,
displays) subject to rinsing the surface with water after application.
Application - guidelines:
The product is a blend of highly eective surface-active alkaline
detergents;
Surfactant foam generated by FRIONETT 2 eectively dissolves and
removes dirt, grease, tarnish and oils;
Contains no fat;
In the case of specialized applications, please check the product
MSDS.

1.
2.
3.
4.
ZGODNY Z NORMAMI
Bactericidal NFEN 1040
Legionella T 72 300-301
Salmonella T 72 300-301
Listeria T 72 300-301
Fungicidal NFEN 1275
Certicate from the PZH HK/M/0102/01/2005
PAN STRIPS BOX: 12PCS X 14G
Prevents from micro-organisms, bacteria (Legionella), mould, slime,
algae and viruses;
14 g individual strips have anti-corrosion, freshening and disinfecting
properties for up to six months;
A bulk package contains 12 boxes.
Certicate from the Polish National Institute of Hygiene number PZH
HK/M/0102/03/2005 HVAC/R
HVAC/R Pan Strips for condensates are used for drip pans in units
such as air conditioners and dehumidiers;
They successfully eliminate and control unpleasant smells caused by
mould, fungi and bacteria;
Special slow release system prolongs activity of the agent for up
to six months;
This product eectively cleans water and holds the development of
mould.
It generates pleasant smell when active;
It is suitable for use in hotels, schools, hospitals, medical rooms,
airports, etc.

1.
2.
3.
4.
5.
6.
Products for cleaning air conditioning devices
35
Air conditioner catalog
Notes
Centrum Klima S.A.
36
More information on www.klimatyzatorymistral.pl
Piastw
Poland
05-820 Piastw, 4 Noakowskiego street
phone +48 22 753 71 72
fax +48 22 753 42 80
Monday Friday, 8 am 4 pm
Saturday, 8 am 2 pm
Warszawa
Poland
02-237 Warsaw, 7b Instalatorw street
phone +48 22 868 25 28
fax +48 22 886 48 87
Monday Friday, 8 am 4 pm
MAP LOCATION
Outline map of Warsaw with access routes
to Centrum Klimas oce and warehouses.
1 Head oce PIASTW
2 Branch WARSZAWA
1
2
1. Products, technical details and prices were included herein only for information purposes. They may change, for instance
due to product upgrade, without prior notice and should not be understood as Centrum Klimas direct oer. The company
may not be held responsible for potential mistakes or inaccuracies which may arise herein.
2. The products and prices expressed herein do not include VAT and are not a business oer in the meaning of
commercial law regulations. Centrum Klima reserves the right to alter the prices without any form of notication.
3. All dimensions are expressed in millimetres unless stated otherwise.
Centrum Klima S.A.
www.centrumklima.pl
Centrum Klima S.A.
Distributor
POLAND
05-820 Piastw, 4 Noakowskiego street
tel. +48 22 753 71 72
fax +48 22 753 42 80
POLAND
02-237 Warsaw, 7B Instalatorw street
tel. +48 22 868 25 28
fax +48 22 886 48 87