GRND Blue Generator working SWITCH_H18 White GRND Orange Generator failure SWITCH_H19 White GRND Green Main power failure SWITCH_H20 White GRND Brown AC power Failure SWITCH_H21 White GRND Grey DC voltage (higher/lower) SWITCH_H22 Red GRND Blue rectifier unit fault SWITCH_H23 Red GRND Orange battery LVD SWITCH_H24 Red GRND Green Aircondition1 Failure SWITCH_H25 Red GRND Brown Aircondition2 Failure SWITCH_H26 Red GRND Grey Temperature Alarm SWITCH_H27 Black GRND Blue Humidity Alarm SWITCH_H28 Black GRND Orange Door Alarm SWITCH_H29 Black GRND Green Smoke Alarm SWITCH_H30 Black GRND Brown Water Alarm SWITCH_H31 Black GRND Grey Commercial Power failure SWITCH_H32 Yellow GRND Blue indoor ALARM NAME STARTPT SIGNAL COLOR X1.19 SWITCH_H1 White X1.3 GRND Green X1.18 SWITCH_H2 White X1.2 GRND Orange X1.21 SWITCH_H3 White X1.5 GRND Grey X1.20 SWITCH_H4 White X1.4 GRND Brown X1.22 SWITCH_H5 Red X1.6 GRND Blue X1.17 SWITCH_H6 White X1.1 GRND Blue X1.23 SWITCH_H7 Red X1.7 GRND Orange X1.24 SWITCH_H8 Red X1.9 GRND Brown X1.25 SWITCH_H9 Red X1.10 GRND Grey X1.26 SWITCH_H10 Black X1.11 GRND Blue X1.27 SWITCH_H11 Black X1.12 GRND Orange X1.28 SWITCH_H12 Black X1.13 GRND Green X1.29 SWITCH_H13 Black X1.14 GRND Brown X1.35 SWITCH_H14 Black X1.34 GRND Grey X1.37 SWITCH_H15Yellow X1.36 GRND Blue X1.38 SWITCH_H16 Red X1.8 GRND Green BR Mostafa Mohamed Talaat BSS O&M Eng. ALKAN Networks O&M BU. Outdoor Lower oil level Generator 1 working Generator 1 failure Main Power Failure Generator 2 Running Generator 2 failure Area: Delta- Sinai Region Office: Zagazig Mobile: 0116606995 Email: Mostafa.Talaat@alkancit.com www.alkancit.com Blue Orange Blue Orange White White White White Green Brown Green Brown White White White White Grey Blue Grey Blue White Red White Red Orange Green Orange Green Red Red Red Red Brown Grey Brown Grey Red Red Red Red Blue Orange Blue Orange Black Black Black Black Green Brown Green Brown Black Black Black Black Grey Blue Grey Blue Black Yellow Black Yellow BR Mostafa Mohamed Talaat BSS O&M Eng. ALKAN Networks O&M BU. Area: Delta- Sinai Region Office: Zagazig Mobile: 0116606995 Email: Mostafa.Talaat@alkancit.com www.alkancit.com TX11 RX16 RX9 TX9 RX10 RX11 TX10 TX12 TX13 TX14 TX6 TX15 TX5 RX12 RX13 RX14 RX15 TX16 Pair 2 RX1 TX1 RX2 TX2 RX3 TX3 RX7 TX7 RX8 TX8 Pair 1 RX4 TX4 RX5 RX6 Pin assignment for the wires of the 120-ohm E1 twisted pair cable for RTN 950 NO NO Orange Wire Color Wire Color RX1,9,17,25,33 Blue TX1,9,17,25,33 Blue White White RX2,10,18,26,3 4 White White RX3,11,19,27,3 5 Green TX3,11,19,27,35 Green White White TX2,10,18,26,34 Orange RX4,12,20,28,3 6 Brown TX4,12,20,28,36 Brown White RX5,13,21,29,3 7 Gray TX5,13,21,29,37 Gray White White TX6,14,22,30,38 Blue Red Red White Pin assignment for the wires of the 120-ohm E1 twisted pair cable for RTN 620 RX8,16,24,31,4 0 Green TX8,16,24,31,40 Green Red Red RX7,15,23,31,3 9 Orange TX7,15,23,31,39 Orange Red Red RX6,14,22,30,3 8 Blue NO NO Ground Ground Ground Ground Ground BR Mostafa Mohamed Talaat BSS O&M Eng. ALKAN Networks O&M BU. white-red Long White-black long grey-red long yellow-red4 - - - - purple-red3 - - - RX8,16,24,31, 40 White-Red2 - - TX8,16,24,31, 40 Grey-Black Long Yellow-Red1 - White-Red1 - RX7,15,23,31, 39 White-Red4 - - - - TX7,15,23,31, 39 Yellow-Red3 - - - White-Red3 - - - Yellow-Red2 - - RX6,14,22,30, 38 White-Black2 - - TX6,14,22,30, 38 Yellow-Black1 - White-Black1 - Yellow-Red Long RX5,13,21,29, 37 White-Black4 - - - - TX5,13,21,29, 37 Yellow-Black3 - - - White-Black3 - - - Yellow-Black2 - - RX4,12,20,28, 36 Grey-Red2 - - TX4,12,20,28, 36 Yellow-Black Long Grey-Red1 - Yellow-Black4 - - - - RX3,11,19,27, 35 Grey-Red4 - - - - TX3,11,19,27, 35 Purple-Red2 - - Grey-Red3 - - - Purple-Red1 - RX2,10,18,26, 34 Grey-Black2 - - TX2,10,18,26, 34 Purple-Red Long Grey-Black1 - Purple-Red4 - - - - Pin assignment for the wires of the 120-ohm E1 twisted pair cable for NEC Wire Color Wire Color RX1,9,17,25,3 3 Grey- Black4 - - - - TX1,9,17,25,3 3 Brown Grey-Black3 - - - Black Area: Delta- Sinai Region Office: Zagazig Mobile: 0116606995 Email: Mostafa.Talaat@alkancit.com www.alkancit.com NO NO BR Mostafa Mohamed Talaat BSS O&M Eng. ALKAN Networks O&M BU. Area: Delta- Sinai Region Office: Zagazig Mobile: 0116606995 Email: Mostafa.Talaat@alkancit.com www.alkancit.com Red Gray White Blue Red Orange Red RX2 Orange TX2 White Green RX4 Brown TX4 White RX3 Green TX3 White Pin assignment for the wires of the 120-ohm E1 twisted pair cable for Node B 3900 Wire Color Wire Color RX1 Blue TX1 White NO NO BR Mostafa Mohamed Talaat BSS O&M Eng. ALKAN Networks O&M BU. Area: Delta- Sinai Region Office: Zagazig Mobile: 0116606995 Email: Mostafa.Talaat@alkancit.com www.alkancit.com RX4 Brown TX4 Green White Red RX3 Green TX3 Orange White Red RX2 Orange TX2 Blue White Red Pin assignment for the wires of the 120-ohm E1 twisted pair cable for BTS 3900 Wire Color Wire Color RX1 Blue TX1 Gray White White NO NO BR Mostafa Mohamed Talaat BSS O&M Eng. ALKAN Networks O&M BU. Area: Delta- Sinai Region Office: Zagazig Mobile: 0116606995 Email: Mostafa.Talaat@alkancit.com www.alkancit.com GREY Pin assignment for the wires of the 120-ohm E1 twisted pair cable for BTS 3012 Wire Color Wire Color RX1 RX2 RX4 WHITE WHITE BROWN GREEN TX2 TX3 TX4 RX3 RED RED GREEN ORANGE RED WHITE BLUE WHITE WHITE ORANGE BLUE TX1 Appearance of the EMU This describes the appearance of the two EMU models. Appearance of EMU model A Figure 1 and Figure 2 show the appearance of EMU model A and its front panel respectively. Figure 1 Appearance of EMU model A Figure 2 Front panel of EMU model A (1) Six ports for Boolean signal output (2) Port for water sensors (3) Port for door status sensors (4) Port for smoke sensors (5) Port for humidity/temperature sensors (6) Port for infrared sensors (7) Four ports for analog signal sensors (8) RS-232 port (9) Active/standby power port (10) Two RS-485 ports (11) Grounding screw (12) Thirty-two ports for Boolean signal sensors Appearance of EMU model B Figure 3 and Figure 4 show the appearance of the EMU model B and its front panel respectively Figure 3 Appearance of EMU model B Figure 4 Front panel of EMU model B (1) Six ports for Boolean signal output (2) Port for water sensors (3) Port for door status sensors (4) Port for smoke sensors (5) Port for humidity/temperature sensors (6) Port for infrared sensors (7) Four ports for analog signal sensors (8) RS-232 port (9) Active/standby power port (10) Two RS-485 ports (11) Grounding screw (12) Thirty-two ports for Boolean signal sensors BR Mostafa Mohamed Talaat BSS O&M Eng. ALKAN Networks O&M BU. Area: Delta- Sinai Region Office: Zagazig Mobile: 0116606995 Email: Mostafa.Talaat@alkancit.com www.alkancit.com ALARM NAME Boolean Value Aircondition1 Failure 1 Aircondition2 Failure 2 Generator failure 3 gen not outo 4 Generator working 5 battery charge 12 Main power failure 13 DC voltage (higher/lower) 14 rectifier unit fault 15 battery LVD 16 Water Alarm 17 Temperature Alarm 18 Smoke Alarm 19 Door Alarm 20 Humidity Alarm 24 ALARM NAME Boolean Value Aircondition1 Failure 1 Aircondition2 Failure 2 Generator failure 3 gen not outo 4 Generator working 5 battery charge 12 Main power failure 13 DC voltage (higher/lower) 14 rectifier unit fault 15 battery LVD 16 Water Alarm 17 Temperature Alarm 18 Smoke Alarm 19 Door Alarm 20 Humidity Alarm 24 Basic Theory: T-568A Straight-Through Ethernet Cable BR Mostafa Mohamed Talaat BSS O&M Eng. ALKAN Networks O&M BU. Area: Delta- Sinai Region Office: Zagazig Mobile: 0116606995 Email: Mostafa.Talaat@alkancit.com www.alkancit.com By looking at a T-568A UTP Ethernet straight-thru cable and an Ethernet crossover cable with a T-568B end, we see that the TX (transmitter) pins are connected to the corresponding RX (receiver) pins, plus to plus and minus to minus. You can also see that both the blue and brown wire pairs on pins 4, 5, 7, and 8 are not used in either standard. What you may not realize is that, these same pins 4, 5, 7, and 8 are not used or required in 100BASE-TX as well. So why bother using these wires, well for one thing its simply easier to make a connection with all the wires grouped together. Otherwise you'll be spending time trying to fit those tiny little wires into each of the corresponding holes in the RJ-45 connector Colors and Wiring Guide Diagram for the 120-ohm twisted pair cable for RJ45 T-568A Straight-Through Ethernet Cable Colors and Wiring Guide Diagram for the 120-ohm twisted pair cable for RJ45 BR Mostafa Mohamed Talaat BSS O&M Eng. ALKAN Networks O&M BU. Area: Delta- Sinai Region Office: Zagazig Mobile: 0116606995 Email: Mostafa.Talaat@alkancit.com www.alkancit.com Wiring Guide Diagram cable for RTN 9(male) -9(female) connector Wiring Guide Diagram cable for RTN 9(male) -9(female) connector BR Mostafa Mohamed Talaat BSS O&M Eng. ALKAN Networks O&M BU. Area: Delta- Sinai Region Office: Zagazig Mobile: 0116606995 Wiring Guide Diagram cable for NEC V4 9(male) -15(female) connector Email: Mostafa.Talaat@alkancit.com www.alkancit.com Wiring Guide Diagram cable for NEC V4 9(male) -15(female) connector